Automation P ducts DataModule —r o 800 Corp Cipher Technol ogies Ltd 552 1 G R EE N V IL L E A VE , # 104 , S U IT E 81 9 , D A LL AS , T X 75231 Phone: (214) 691-2506, (469) 877-8811 Multi-channel Controller D ESCRIPTION T h e D a t a Mo d u l e - 8 0 0 i s a n o t h e r i n a l i ne o f d e p e n d a b l e a n d a c c u r a t e l e v e l a n d c o n t r o l e q u i p m en t f r om Cipher Technologies. T h e D M- 8 0 0 c a n a c c e p t a n d p o we r E I G H T 4 - 2 0 m A a n a l o g s e n s o r s , a s we l l a s a c c e p t T W O p u l s e i n p u t s! T h e D M- 8 0 0 o f f e r s t h e a b i l i t y t o d i s p l a y u p t o E I G H T c h a n n e l s i n e n g i n e er i n g u n i t s wi t h t h e i r c o r r e s p o n d i n g b a r - g r a p h s . A n d , t he b a r - g r a p h s c a n b e i n d e p e n d e n t l y s c a l e d t o t h e e n g i n ee r i n g u n i t s! DataModule 800 Features... • Ability to read EIGHT 4-20 mA sensors • Ability to read TWO pulse inputs • EIGHT Relay Outputs with adjustable: Dead-band and time delay Pulse Width and time between Pulses • TWO 4-20 mA programmable outputs • MOD-BUS RTU RS-232 Interface • Ninth Alarm Relay Supervisory or summary alarm • LARGE backlit easy to read display • LARGE bar graphs with user definable scale • Easy to configure and use Automated sensor calibration Menu driven setup PC configurable Channel can be named (i.e. Tank 1) • Summary Page showing: Engineering Value Channel Name Engineering Scale Sensor input (mA or Hz) Alarms set points and status Can display digits in Feet and Inches • Manual Relay Mode • Universal supply voltage 8 to 30 VDC or 120 VAC • Password protection available for configuration • Transient Voltage Protection on all Inputs and Outputs • PID Control Output Available T h e E I G H T r e l a y o u t p u t s c a n b e a s s i g n ed i n AN Y c o m b i n a t i o n t o AN Y i n p u t c h a n n e l . T h e r e l a y o u t p u t s c a n b e u s e d f o r a l a rm s , p u m p - c o n t ro l , a n d / or electric actuator control. T h e D M- 8 0 0 c a n b e programmed to control on f l o w r a t e wi t h a p r e s s u r e o v e r r i d e o r c o n t r o l on p r e s s u r e wi t h a f l o w- r a t e override! W i t h a L AR G E a n d e a s y t o r e a d b a c k li t L C D d i sp l a y the DM-800 is extremely DataModule 800 Applications... • Digital Readouts for: Casing Pressure Tubing Pressure Flow Rates Tank Level etc.... • Suction and discharge pressure display and control • Temperature display with peak and valley hold feature • Timed pulsed outputs for Injection Choke Control • Outputs to throttle valves to regulate tank level and pipeline pressure • Tank level indication and pump control • Gas detection and alarm DataModule-800 Multi-channel Automation Products Corp Controller D ESCRIPTION (c ontinued) DataModule-800 Specifications... • Power • Inputs 102-140 VAC 60 Hz or 8-30 VDC (8) 4-20 mA Inputs The DV-100 can supply the loop current for two wire loops For three wire loops use external +24 VDC power supply • PID Fully Programmable PID Control and Set-Point Input • Pulse Inputs (2) Vin: 100 mV to 15 V Frange: 0.1 Hz to 50 kHz • Output Loop Impedance 0-300 Ohms Assuming +12 VDC is the minimum voltage of the transmitter • Relay Outputs (8) total with 100 % adjustable dead-band and delay • Relay Settings Can be set to normally open or close with any combination of lows or highs • Relay Assignments Any number of contacts can be assigned to any channel • Contact Rating 2 Amps @ 120 VAC • Data Display (6) full digits • Programmable Relays Adjustable pulse width, time between pluses, and time delay • Channel Display Full graphics—Backlit • Engineering Units Feet & Inches, Ounces, PSI, GPM, LBS, no units, Barrels, Meters, Cubic Meters, Gallons, °F, °C, PPM, % level, % volume, and user definable units • Bar graphs One per channel • Operating Temperature -20°F to 120°F • Short Circuit Protection Analog inputs are individually fused • Lightning Protection Analog inputs have chokes and TVS’s Power inputs have MOV’s and is fused • Terminals 5.08 mm (0.2”) Plug on • Trouble or Summary Alarm Extra output relay contact: As a supervisory alarm it will engage if the following occurs: CPU failure, Loss of power, Loss of transmitter input, or if an transmitter is out of acceptable range. As a summary alarm it will engage if the other relays are engaged. • Remote Communications MOD-BUS RTU RS-232 Interface • Pressure/Rate Override Programmed in the setup procedure • Dimensions 7¼” W x 8½” L x 1½” H C ip h er T ech n ol ogi es, L td 552 1 G RE ENVILLE A VE , # 104 , S UITE 819 , D ALL AS , T X 75 231 Phone: (214) 691-2506, (469) 877-8811, sales@ciphertechnology.com
© Copyright 2024