Multi-channel Controller
D ESCRIPTION
T h e D a t a Mo d u l e - 8 0 0 i s a n o t h e r i n a l i ne o f d e p e n d a b l e
a n d a c c u r a t e l e v e l a n d c o n t r o l e q u i p m en t f r om
Cipher Technologies.
T h e D M- 8 0 0 c a n a c c e p t a n d p o we r E I G H T 4 - 2 0 m A
a n a l o g s e n s o r s , a s we l l a s a c c e p t T W O p u l s e i n p u t s!
T h e D M- 8 0 0 o f f e r s t h e a b i l i t y t o d i s p l a y u p t o E I G H T
c h a n n e l s i n e n g i n e er i n g u n i t s wi t h t h e i r c o r r e s p o n d i n g
b a r - g r a p h s . A n d , t he b a r - g r a p h s c a n b e i n d e p e n d e n t l y
s c a l e d t o t h e e n g i n ee r i n g u n i t s!
DataModule 800 Features...
• Ability to read EIGHT 4-20 mA sensors
• Ability to read TWO pulse inputs
• EIGHT Relay Outputs with adjustable:
Dead-band and time delay
Pulse Width and time between Pulses
• TWO 4-20 mA programmable outputs
• MOD-BUS RTU RS-232 Interface
• Ninth Alarm Relay
Supervisory or summary alarm
• LARGE backlit easy to read display
• LARGE bar graphs
with user definable scale
• Easy to configure and use
Automated sensor calibration
Menu driven setup
PC configurable
Channel can be named (i.e. Tank 1)
• Summary Page showing:
Engineering Value
Channel Name
Engineering Scale
Sensor input (mA or Hz)
Alarms set points and status
Can display digits in Feet and Inches
• Manual Relay Mode
• Universal supply voltage
8 to 30 VDC or 120 VAC
• Password protection available for
configuration
• Transient Voltage Protection on all
Inputs and Outputs
• PID Control Output Available
T h e E I G H T r e l a y o u t p u t s c a n b e a s s i g n ed i n AN Y
c o m b i n a t i o n t o AN Y i n p u t c h a n n e l . T h e r e l a y o u t p u t s
c a n b e u s e d f o r a l a rm s ,
p u m p - c o n t ro l , a n d / or
electric
actuator control.
T h e D M- 8 0 0 c a n b e
programmed to control on
f l o w r a t e wi t h a p r e s s u r e
o v e r r i d e o r c o n t r o l on
p r e s s u r e wi t h a f l o w- r a t e
override!
W i t h a L AR G E a n d e a s y t o
r e a d b a c k li t L C D d i sp l a y
the DM-800 is extremely
DataModule 800 Applications...
• Digital Readouts for:
Casing Pressure
Tubing Pressure
Flow Rates
Tank Level
etc....
• Suction and discharge pressure display and control
• Temperature display with peak and valley hold
feature
• Timed pulsed outputs for Injection Choke Control
• Outputs to throttle valves to regulate tank level and
pipeline pressure
• Tank level indication and pump control
• Gas detection and alarm
DataModule-800
Multi-channel
Automation Products
Corp
Controller
D ESCRIPTION
(c ontinued)
DataModule-800 Specifications...
• Power
• Inputs
102-140 VAC 60 Hz or 8-30 VDC
(8) 4-20 mA Inputs
The DV-100 can supply the loop current for two wire loops
For three wire loops use external +24 VDC power supply
• PID
Fully Programmable PID Control and Set-Point Input
• Pulse Inputs
(2) Vin: 100 mV to 15 V Frange: 0.1 Hz to 50 kHz
• Output Loop Impedance 0-300 Ohms Assuming +12 VDC is the minimum
voltage of the transmitter
• Relay Outputs
(8) total with 100 % adjustable dead-band and delay
• Relay Settings
Can be set to normally open or close with any
combination of lows or highs
• Relay Assignments
Any number of contacts can be assigned to any channel
• Contact Rating
2 Amps @ 120 VAC
• Data Display
(6) full digits
• Programmable Relays
Adjustable pulse width, time between pluses, and
time delay
• Channel Display
Full graphics—Backlit
• Engineering Units
Feet & Inches, Ounces, PSI, GPM, LBS, no units, Barrels, Meters,
Cubic Meters, Gallons, °F, °C, PPM, % level, % volume, and
user definable units
• Bar graphs
One per channel
• Operating Temperature -20°F to 120°F
• Short Circuit Protection Analog inputs are individually fused
• Lightning Protection
Analog inputs have chokes and TVS’s
Power inputs have MOV’s and is fused
• Terminals
5.08 mm (0.2”) Plug on
• Trouble or Summary
Alarm
Extra output relay contact:
As a supervisory alarm it will engage if the following occurs:
CPU failure, Loss of power, Loss of transmitter input, or if an
transmitter is out of acceptable range.
As a summary alarm it will engage if the other relays are
engaged.
• Remote Communications MOD-BUS RTU RS-232 Interface
• Pressure/Rate Override Programmed in the setup procedure
• Dimensions
7¼” W x 8½” L x 1½” H
C ip h er T ech n ol ogi es, L td
552 1 G RE ENVILLE A VE , # 104 , S UITE 819 , D ALL AS , T X 75 231
Phone: (214) 691-2506, (469) 877-8811, sales@ciphertechnology.com