HSB HSB Industrieelektronik Industrieelektronik 2 3 4 5 6 * these functions are required for B1and B2 manual Function Time 2 3 4 5 6 0,05 - 1s Ansprechverzögert ; On delay ; Retard á la mise sous tension microcontrollerswitched serie 17,5 mm article – nr. ZMR1 – 11.021.00.001 ZMR2 – 11.022.00.001 2 3 4 5 6 Abfallverzögert ; Off delay ; Retard au déclenchement * Multifunctions timer ZMR 0,5 - 10s 5 4 3 2 6 5 4 3 2 1 6 Einschaltwischend ; Single pulse on ; Temporisation á la mise sous tension 3 - 60s 15 - 300s 6 5 4 3 2 6 5 4 3 2 6 5 4 3 2 6 5 4 3 2 0,5 - 10 min. Blinkend-Pause ; Flasher beginning with off ; Clignotant démarrant par une impulsion Supply voltage A 3 B 1 1 5 15 - 300 min. 0,5 - 10 h 2 5 ZMR1 A 1 X ZMR2 A 3 X 62 8 1 61 82 X B 2 A 2 1 A 1 B 1 A 1 2 5 2 8 A 3 2 6 B 1 18 K1 A 2 1 6 B 2 1 5 1 8 X K1 B2 A2 X 15 B1 A1 Operating mode: Supply voltage influence: Temperature influence: Recovery time: Repetitive accuracy: Timing range : 230V AC +/- 15% 24V AC/DC +/- 15% 0 / 50 ... 60Hz approx. 1.0 W with 24V AC/DC approx. 6 VA with 230V AC continuous < 0.01% over voltage range < 0.01%/°C > 100ms 0.2% 0,05s - 10h (8 time ranges) Operation indicators Supply voltage: Relay in working position: LED, green LED, yellow Contact Number of changeovers: Contact material: Maximum switching voltage: Maximum switching current: Maximum switching power : contact live : Drop-off time of switching element: 1 or 2 AgNi 0,15 400V AC 8A 2000VA 30 x 106 (mechanical) approx. 20ms General data Ambient temperature: Mounting position: LVD 2006/95/EG : EMC Dir. 2004/108/EG : overvoltage category : contamination degree : test voltage : Isolation : 15/16/18 -> A1/A2/A3/B1/B2 25/26/28 -> A1/A2/A3/B1/B2 15/16/18 -> 25/26/28 Connection terminals: Connection cross section: Mounting: Dimensions l x w x h: Weight: - 25 ... + 60°C any 61812-1 61812-1 3 (300V) 2 (250V) 4kV (1,2/50µs) >3mm ; basic isolation (250V) >3mm ; basic isolation (250V) >6mm ; double isolation (250V) Crosshead screws; M3.5 self-opening 2 x 2.5mm² Symmetrical rail DIN EN 50022 90mm x 17.5mm x 69.5mm ZMR1 - 96g ZMR2 - 104g 3 - 60 min. Blinkend-Impuls ; Slasher beginning with on ; Clignotant démarrant par une coupure Watchdog* Technical data A 2 1 6 B 2 1 5 1 8 Mounting Snap-on mounting using a standard DIN rail EN 50022. The unit is designed to allow side-by-side mounting, with an ambient temperature of < 60°C. |H|S|B| Industrieelektronik GmbH Hans-Boerdlein-Str. 10 97723 Oberthulba Tel: 09736/75759-0 Fax: 09736/75759-20 E-mail: info@hsb-electronics.de Internet: www.hsb-electronics.de A1 / A2: A3 / A2: Frequency range: Power consumption: |H|S|B| Industrieelektronik GmbH Hans-Boerdlein-Str. 10 97723 Oberthulba Tel: 09736/75759-0 Fax: 09736/75759-20 E-mail: info@hsb-electronics.de Internet: www.hsb-electronics.de Anzugsverzögert*: delay on operate*: retard á mise sous tension*: Abfallverzögert: Delay on release: Retard ai dé clenchement: Einschaltwischend*: Pulse on operate*: Temporisation á la mise sous tension*: Ausschaltwischend: Pulse on release: Temporisation au déclenchement dés la fin de l´impulsion: Taktgeber Start mit Impuls*: Flasher beginning with pulse*: Clignotant dé marrant par une impulsion*: Taktgeber Start mit Pause*: Flasher beginning with pause*: Clignotant dé marrant par une coupure*: Drehzahl-,Stillstandsübewachung: Watchdog: Impulsformer: Pulse former: Temporisé à l’impulsion sur la commande: A 1 (A 3 ) / A 2 t t A 1 (A 3 ) / A 2 B1/B2 B1/B2 18 K o n ta k te 1 5 16 K o n ta k te 1 5 t t 18 K o n ta k te 1 5 16 K o n ta k te 1 5 * - ZMR2 mit Sofortkontakt 25/26/28 wenn B1/B2 gebrückt ist; ZMR2 with instantaneous contact, if B1/B2 is briged
© Copyright 2025