UK EUROCODES Damascus University – Spring 2015 Instructor: Dr. Nachwan Khair Lecture 4 Lecture 4 Tension connections Lecture 4 Lecture 4 Tension connections Bolted connection loaded in tension should be designed as one of the following: Category D: non-preloaded In this category bolts from class 4.6 up to and including class 10.9 should be used. No preloading is required. This category should not be used where the connections are frequently subjected to variations of tensile loading. However, they may be used in connections designed to resist normal wind loads. Lecture 4 Tension connections Bolted connection loaded in tension should be designed as one of the following: Category E: preloaded In this category preloaded 8.8 and 10.9 bolts with controlled tightening in conformity with 1.2.7 Reference Standards: Group 7 should be used. Lecture 4 Design resistance Table 3.4 of EN 1993-1-8 lists the design rules for individual bolts subjected to shear and/or tension. For tension the resistance is Where Lecture 4 Design resistance Table 3.4 of EN 1993-1-8 lists the design rules for individual bolts subjected to shear and/or tension. For combined shear and tension the resistance is covered by the formula Lecture 4 Design for block tearing In addition, a new failure mode, block shear, has been observed in a shear joint involving a group of bolts Lecture 5 Design for block tearing Block tearing consists of failure in shear at the row of bolts along the shear face of the hole group accompanied by tensile rupture along the line of bolt holes on the tension face of the bolt group. Figure 3.8 shows block tearing. Lecture 4 Lecture 4 Design for block tearing For a symmetric bolt group subject to concentric loading the design block tearing resistance, Veff,1,Rd is given by: where: Ant is net area subjected to tension; Anv is net area subjected to shear. Lecture 4 Design for block tearing For a bolt group subject to eccentric loading the design block shear tearing resistance Veff,2,Rd is given by: Lecture 4 Eccentric connections There are two principal types of eccentrically loaded connections: 1. Bolt group in direct shear and torsion; and 2. Bolt group in direct shear and tension. 1. 2. Lecture 5 1. Bolt group in direct shear and torsion the moment is applied in the plane of the connection and the bolt group rotates about its centre of gravity. A linear variation of loading due to moment is assumed, with the bolt furthest from the centre of gravity of the group carrying the greatest load. The direct shear is divided equally between the bolts and the side plates are assumed to be rigid. Lecture 4 1. Bolt group in direct shear and torsion 1 O Lecture 4 1. Bolt group in direct shear and torsion F1 F F 2Fv1FM 1 cos 2 v1 2 M1 1 M Ed r1 FM 1 2 2 xi yi FM1 F1 θ O VEd Fv1 n MEd VEd Lecture 4 FV1 r1 2. Bolt in direct shear and tension For tension the resistance is Where Lecture 4 2. Bolt in direct shear and tension For combined shear and tension the resistance is covered by the formula Lecture 4 2. Bolt in direct shear and tension An approximate method of analysis that gives conservative results is described first. A bracket subjected to a factored load P at an eccentricity e The centre of rotation is assumed to be at the bottom bolt in the group. The loads vary linearly as shown on the figure, with the maximum load FT in the top bolt. The moment of resistance of the bolt group is: MR = 2[FT · y1 + FT · y22 / y1 + · · · ] = 2FT/y1 · [y21 + y22 + …] = 2FT/y1 .∑ y2 =P.e The maximum bolt tension is: FT = P · e · y1/(2 . ∑ y2) The vertical shear per bolt: FS = P/No. of bolts Lecture 4 2. Bolt in direct shear and tension Lecture 4 مالحظة هامة: يمنع الكتابة على الكود منعا ً باتا ً وإضافة أي جداول غير المصرح بها من قبل أساتذة المقرر. Lecture 4 Lecture 4
© Copyright 2024