178 kB 25th May 2015 Vector R90 Electrostatic Spray Product Data

Product data sheet
Vector R90
electrostatic spray
penetrant processing inspection equipment
General Description
9060 LV3 low voltage power supply
The Vector R90 represents the latest advance in electrostatic spray guns. It is available on its own or in conjunction
with the 9060 LV3 low voltage power supply.
The compact 9060 LV3 low voltage power supply has been
designed to keep your Vector spray gun running smoothly.
It provides low voltage to the applicator, which is then
converted to high voltage for optimum performance and
transfer efficiency. The unit is designed to optimise the
charging process under varying load conditions and to limit
the operating current to a safe maximum value.
The Vector R90 incorporates triple set point control, putting
unparalleled voltage control and flexibility at your fingertips.
A single switch turns the voltage on and off and can move
between three pre-selected voltage levels.
• Increased durability
The control panel is user friendly with easy-to-read displays
for adjusting voltage or current, as well as indicators for
cable fault or overload, and a reset switch. Other features
include:
• Reduced trigger pull. The dual stage air valve eliminates
air to fluid transition.
• A variable voltage output to drive a cascade in the gun
to amplify the voltage to kV level.
• Lighter weight with improved ergonomics
• Interlock connections for a conveyor and exhaust fan.
• Improved electronic controls: The R90’s control unit
offers microprocessor-based control for data collection.
• In remote mode, the selection and adjustment of the set
point can be performed using either discrete or analog
I/O signals.
Product Features
• Certified pre-tested air caps designed for consistency.
The result is an improved finish with fewer rejects.
Specification and Operating Data
Atomisation
Length
Weight
Air/fluid operating pressure
Conventional air
29.2 cm
555 g
400 psi
• Safety features: Detection of ground faults, cable faults,
feedback signal faults, over voltage and over current.
Size
16.5 cm (H) x 37.8 cm (W) x
30.7 cm (D)
Weight
10.2 Kg
Input voltage
Frequency
90 - 264 VAC
50 or 60 Hz
Tip voltage
85 kV
Current
1.5 A maximum RMS
Maximum current
90 µA
Wattage
40 W (maximum)
Maximum fluid temperature
65°C
Output voltage
Maximum fluid delivery
1,000 cm3/min
20 - 90 kV (maximum DC)
All units carry the CE mark and conform to the appropriate
EU directives.
Faraday Road, South Dorcan Industrial Estate, Swindon, Wiltshire, SN3 5HE, UK
T + 44 (0)1793 524566 F +44 (0)1793 490459 E sales@magnaflux.co.uk
T +49 (0) 7365 81-0
Version 14.1
Bahnhofstr 94-98, 73457 Essingen, Germany
F +49 (0) 7365 81-449 E sales@magnaflux.com.de
T +46 54 29 39 50
P.O. Box 530, 651 12 Karlstad, Sweden
F +46 54 85 05 58 E info@magnaflux.se