Datasheet

MESH Gateway
HDL-MCIP-RF.10
Parameters
Overview
Electric Parameters:
Working power
12~30VDC
Communication
RJ45,HDL-BUS,RF
Wireless transmit power
+10dbm
Wireless receive sensitivity
-90dbm
Communication distance indoor
50m (barrier free)
Work mode
Mesh mode, bridge mode
BUS Terminal
Wago 252,0.75-0.85mm Diame-
HDL MCIP-RF.10 is a gateway based on IEEE802.15.4 standard
ter Single Core
MESH technology. Mesh Wireless Gateway has three communication interfaces: RJ45, HDL-BUS, RF, which can interconnect
Wireless central frequency
(China) WPAN
780MHz-786MHz
different media platforms (RS485, Ethernet, RF) of HDL intelli-
(Europe) SRD
864MHz-870MHz
gent devices .
(North America) ISM
904MHz-928MHz
At the same time, this device can also be configured as transparent transmission (bridge) mode. RS485 and Ethernet data in
Environmental Conditions:
multiple gateways can be transmitted from RF, which effectively
Working Temperature
0℃~45℃
Working relative Humidity
Up to 90%
Storage Temperature
-20℃~+60℃
Storage relative Humidity
Up to 93%
extends the communication distance. In the inconvenient of
layout application environment, subnets can interconnect with
wireless (RF).
Functions
Approve:
CE
RoHS
Production Information:
■
Can be configured as Mesh mode.
■
Can be configured as Bridge (transparent transmission)
mode.
Dimension
107×99.5×27(mm)
Weight
103g
■
Communication data rate is higher than the cable.
Important Notes
Housing material
ABS
Installation
Desk or wall mounted
Protection Degree
IP20
■
Check the HDL Bus connection, avoid any mistakes
■
In MESH mode, different RF channels must be different
for each gateway, each gateway manages a wireless
network with same SubNet ID. In Bridge mode, RF chan-
HDL-BUS Definition for Cable
HDL-BUS
HDL-Bus/KNX
DC24V
Red
COM
Black
DATA-
White
DATA+
Yellow
Installation Step
■
nel must be the same as each gateway.
■
the same as RF devices which is managed by the gateway, and port ID is unique in RS485 port
■
Two or more devices Ethernet (RJ45) can not be connect
ed with RS485 port , otherwise loop connection will block
communication
■
Must select free RF frequency for different countries, user
can set new wireless transmission password before installation.
Bus cable - HDL Bus/KNX cable, 0.8mm single-core copper
cable.
In Mesh mode, subnet ID of Gateway in RF port must be
■
Reliable transmission distance is 50m, obstacles will
■
Bus Connection - Series connection (hand-in-hand).
reduce the transmission distance, the distance will de-
■
Connect to DC24V power.
crease 20m if the wall stops it. So it is better to install
■
If needed, connect to RJ45.
Mesh wireless devices in empty place and forbid to install
near large area of metal objects. To ensure good communication quality, it is suggested not to install this device in
electric box. If you have to, please add an external antenna to the device.
Professional Home and Building Automation
www.hdlautomation.com
Do you need help? Contact with us
support1@hdlchina.com.cn
1/ 2
www.hdlchina.com
MESH Gateway
HDL-MCIP-RF.10
Layout and Wiring
Antenna
PROG: programming key
Pressing it for 3 successive times. Red LED gateway will be switched to set channel for Parameter settings,
HDL-BUS
user can program wireless devices by HDL Easy Engineering Editor
Long press for 3 seconds to change ID in HDL Easy Engineering Editor software,
99.5
Working LED
Long press for 10 seconds to default factory IP(192.168.10.250)
Antenna: receives and transmits wireless signal.
Working LED: Green LED flashes during normal operation and last for seconds each time.
107
LED Indicator:
Red LED flashes quickly when it is programming.
HDL-BUS
24VDC: power supply, if the device
Green LED flashes when it receives or transmits
27 connects to the HDL-BUS, it need not
connect to DC power
wireless signal.
Red/Green
RJ45: Ethernet port RJ45
All indicators are on, the device will be restored
Blue
into default setting from factory.
The Y of SubNet ID range in wired Bus is 0-254,X
RJ45
SUB ID
X
X
X
X
Device ID
1
2
...
64
Mesh
Panel
…...
Mesh
Relay
value is different from Y
HDL Mesh gateway
HDL-Bus
SUB ID: X
Mesh
Curtain
…...
Device ID: 0
Relay
SUB ID
The X of SubNet ID range in RF network is 0-254,Y value is different
Mesh mode
from X. The gateway‘s device ID is 0, can not change it.
Device ID
Relay
Y
1
Dimmer
Y
Y
Y
2
...
64
RJ45
HDL-Bus
The SUB ID NO. is Y1
Relay
SUB ID
Device ID
Y1
1
Dimmer
Y1
2
…...
HDL Mesh gateway1
SUB ID: X1
Relay
Y1
Y1
...
64
Device ID: 0
Device ID: 0
RF
Relay
Dimmer
…...
HDL Mesh gateway 2
SUB ID: X2
Relay
SUB ID
Y2
Y2
Y2
Y2
Device ID
1
2
...
64
Device ID: 0
SUB ID
RF
…...
Relay
Relay
Y3
Y3
Y3
Y3
2
...
64
Device ID 1
Dimmer
RF
RF
The SUB ID NO. is Y2
HDL-Bus
The SUB ID NO. is Y3
HDL-Bus
HDL Mesh gateway 3
SUB ID: X3
The SUB ID NO. is Y4
HDL-Bus
HDL Mesh gateway 4
SUB ID: X4
Device ID: 0
Relay
Bridge mode
Dimmer
…...
Dimmer
SUB ID
Y4
Y4
Y4
Y4
Device ID
1
2
...
64
In Bridge mode, all SubNet ID of gateway devices are different
Safety attention
■
Do not make wrong connection on Bus interface, it will damage the Bus interface of this module.
■
Never let liquids get into the module, it will damage this device.
■
Do not get AC240V voltage into Bus wire , it will damage all devices in the system.
■
Ensure good ventilation.
Professional Home and Building Automation