ISIS™inVIRONMENTHeat&A/CControllerModule forVintageAirGen‐IV TableofContents Overview .......................................................................................................................................... 2 Kit Includes ...................................................................................................................................... 3 Installation Steps ............................................................................................................................. 4 Connect the inVIRONMENT module to the Vintage Air Gen‐IV ECU. .......................................... 4 Connect the inVIRONMENT module to the ISIS CAN network. ................................................... 4 Powering Up the System ................................................................................................................. 6 Operating the System ...................................................................................................................... 7 inTOUCH MAX Operation ............................................................................................................ 7 inTOUCH Mobile Operation ........................................................................................................ 8 Switch Control from the MASTERCELL ........................................................................................ 9 Warranty Information ................................................................................................................... 10 Contact Information ...................................................................................................................... 11 1 Rev012/2011 Overview Tostepupyourlevelofcontrolinyourcar,ISISPowerhasdevelopedtheISIS™ inVIRONMENTControlModule.Thisisspecificallyengineeredtogiveyoucomplete controloftheblendposition,fanspeedandtemperaturesettingsonyourVintage AirGen‐IV™System.Younowhavecompletefreedomtocontrolyourheatandair‐ conditioningwiththeISISIntelligentMultiplexSystemthroughyourchoiceof buttonsorswitches.YoualsohavetheflexibilitytocontrolyourVintageAirGen‐IV throughourISISinTOUCHMAXtouchscreenorourISISinTOUCHMobilewireless interface. Ifyouhaveaveryspecificlook‐and‐feelfortheswitchesinyourcar,andyouwant tokeepthatthemeconsistentforyourheat&A/Ccontrols,youcanuseanypush buttonsortoggleswitcheswithinVIRONMENT.TheseinputstotheMASTERCELL canbeusedtoincreaseanddecreasethefanspeedandtemperatureplussetthe blendposition. Forahigher‐endinstallation,youcancontrolalloftheheat&A/Csettingsrightoff ofourtouchscreeninterfaces:inTOUCHMAXorinTOUCHMobile.Thisallowsyou tocompletelyeliminatethecontrolsfortheVintageAirGen‐IVandde‐clutteryour dash. TheISISinVIRONMENTcontrolmoduleinterfacesdirectlywiththecontrolleronthe VintageAirGen‐IVevaporatorunit.Itplugsdirectlyintotheirconnectorstotake commandsfromyourswitchesortouchscreenandcontroltheheat&A/Csettings. inVIRONMENTalsoplugsintotheISISCANnetworktoeasilypasscommandsfrom theMASTERCELL.PowerissuppliedtoinVIRONMENTfromthecablepluggedinto theGen‐IVunitsoinstallationiseasy. 2 Rev012/2011 KitIncludes 1‐ISIS™inVIRONMENTHeat&A/CControllerModule 1‐ISIS™inVIRONMENTInterfaceCableforVintageAirGen‐IV3‐PotSeries204ECU 1‐ModularISIS™CANJumperHarnesses 6‐22‐AWGButtSpliceTerminals 6‐PiecesofHeatShrinkTubing 1‐InstructionManual Note TheVintageAirGen‐IVversionofinVIRONMENTisdesignedtointerfacedirectly withevaporatorunitsusingthe3‐potseries204ECU.CheckwithyourVintageAir manualtoconfirmtheversionoftheevaporatorthatyouhave.ContactISIS technicalsupportat(847)232‐1991withotherseriesofVintageAirECU’s. 3 Rev012/2011 InstallationSteps ConnecttheinVIRONMENTmoduletotheVintageAirGen‐IVECU. 1) Removethepositiveterminalfromyourbatteryorbatteriesbeforeinstalling anyelectricalcomponents. 2) ConnectandplumbyourVintageAirsystempertheinstructionsthatcame withyourGen‐IV. a. SplicetheVioletwireinthewireharnessthatplugsintotheECUto theignitionoutputonyourPOWERCELL.Thisistheignitionfeedthat energizestheirsystem. 3) MounttheISIS™inVIRONMENTModuleonorneartheECUontheVintage AirGen‐IVevaporatorunit. 4) Plugtherectangular12‐positionconnectorontheISISinterfacecableinto thematingconnectorontheVintageAirGen‐IVECU.Thisisthesocketfor thecontrolpanelharness. 5) Plugthe4‐positionrectangularconnectorintothePower/Groundsocketon theinVIRONMENTmodule. 6) Plugthe5‐positionrectangularconnectorintotheOutputsocketonthe inVIRONMENTmodule. ConnecttheinVIRONMENTmoduletotheISISCANnetwork. 1) PickaconvenientplaceintheISISCANcabletospliceintoforinVIRONMENT. 2) Removetheconvoluteloomingfromtheareawhereyouwillmakethesplice. 3) Cutandstripthe6wiresintheinVIRONMENTCANjumperharnesstothe rightlengthtospliceintoyourexistingISISCANharness. 4) Locatethepairofblue*22‐AWGwiresintheCANharness.Pickoneofthe bluewiresandcutit.Bothofthebluewiresareelectricallythesamesoyou maychooseeitherbluewire. 5) Stripbacktheinsulationonbothsidesofthecutblue22‐AWGwire. 6) Sliponepieceofheat‐shrinktubingoneachendofthecutblue22‐AWGwire intheexistingCANharness. 7) Crimponeendoftheincludedbutt‐spliceterminalstoeachofthecutendsin theexistingCANharness. 8) Crimptheotherendsofthebutt‐spliceterminalstothebluewiresinthe inVIRONMENTCANjumperharness.Thesewiresareelectricallythesameso itdoesnotmatterwhichofthebluewiresconnecttothebluewiresinyour existingCANharness. 4 Rev012/2011 9) Locatethepairofgreen*22‐AWGwiresintheCANharness.Pickoneofthe greenwiresandcutit.Bothofthegreenwiresareelectricallythesameso youmaychooseeithergreenwire. 10)Stripbacktheinsulationonbothsidesofthecutgreen22‐AWGwire. 11)Sliponepieceofheat‐shrinktubingoneachendofthecutgreen22‐AWG wireintheexistingCANharness. 12)Crimponeendoftheincludedbutt‐spliceterminalstoeachofthecutendsin theexistingCANharness. 13)Crimptheotherendsofthebutt‐spliceterminalstothegreenwiresinthe inVIRONMENTCANjumperharness.Thesewiresareelectricallythesameso itdoesnotmatterwhichofthegreenwiresconnecttothegreenwiresin yourexistingCANharness. 14)Locatetheblack*22‐AWGwireintheCANharness. 15)Stripbacktheinsulationonbothsidesofthecutblack22‐AWGwire. 16)Sliponepieceofheat‐shrinktubingoneachendofthecutblack22‐AWG wireintheexistingCANharness. 17)Crimponeendoftheincludedbutt‐spliceterminalstoeachofthecutendsin theexistingCANharness. 18)Crimptheotherendsofthebutt‐spliceterminalstotheblackwiresinthe inVIRONMENTCANjumperharness.Thesewiresareelectricallythesameso itdoesnotmatterwhichoftheblackwiresconnecttotheblackwiresinyour existingCANharness. 19)Slidethepiecesofheat‐shrinktubingoverthebutt‐splicesintheharness. 20)Useaheat‐guntoshrinkthetubingoverthesplices. 21)Re‐loomtheCANcable. 22)Plugthe3‐positionrectangularconnectorintoeitherofthesocketslabeled CANontheinVIRONMENTmodule. *Note:SomegenerationsofISISCANcablemayhavedifferentwirecolors.Please contactISISPowertechnicalsupportifyourwirecolorsdonotmatchtheones describedabove. 5 Rev012/2011 PoweringUptheSystem 1) Reconnectthebatterytothesystem. 2) Wait5secondsfortheISISsystemtobootup. 3) ChecktoseeiftheISISinVIRONMENTmoduleisinsysteminventory. a. FromaMASTERCELLwiththeinSIGHTLCD i. Pressthe“HOME”button ii. Pressthe“SCROLLDOWN”button iii. inVIRONMENTisinstalledcorrectlyifyousee“CELLAFDA‐4 CH”inthesysteminventory. b. FromaMASTERCELLwithinTOUCHMAX i. Pressthe“TOOLS”buttononthemainscreen. ii. PressISIS01ENDonthetouchscreenkeypad. iii. inVIRONMENTisinstalledcorrectlyifyousee“ISISDA Converter4ChVer1”inthesysteminventory. 6 Rev012/2011 OperatingtheSystem YourISISinVIRONMENTModulecanbecontrolledthreewaydifferentways.The interfacesforinTOUCHMAXandinTOUCHMobilearepracticallyidentical.The sectionsbelowdescribethebuttonsandtheslidersonthesescreens.Youalsohave theoptiontocontrolthesystemthroughswitchestotheMASTERCELL.Seebelow formoreinformation. inTOUCHMAXOperation SeeFigure1forapictureoftheHeat&A/CscreenoninTOUCHMAX. The5buttonsonthetopofthescreencontroltheblendposition.Pressandrelease thesebuttonstochangeairflowbetweentheVent,FloorandDefrost.Therearealso buttonsthatblendtheVent/FloorandtheFloor/Defrost. ThesliderforTempcontrolsthetemperatureoftheaircomingoutofthesystem. Pressandreleaseontheslidertosetthetemperature.TheVintageAirGen‐IV automaticallycontrolstheheatercontrolvalveandtheairconditioningclutchbased onthesettingonthisslider. TheFanslidercontrolsthespeedofthefanontheVintageAirGen‐IVunit.Press andreleaseontheslidertosetthefanspeed.Toshutoffthefan,pressthe0areaon theslider. Figure1:inTOUCHMAXScreencontrolsforHeat&A/C 7 Rev012/2011 inTOUCHMobileOperation ConnectyourmobiledevicetoyourISISsystem.SeetheinTOUCHMobile instructionsformoreinformationonhowtodothis. Figure2showsthelandscapeversionofthescreenfromtheiPhone. The5buttonsonthetopofthescreencontroltheblendposition.Pressandrelease thesebuttonstochangeairflowbetweentheVent,FloorandDefrost.Therearealso buttonsthatblendtheVent/FloorandtheFloor/Defrost. ThesliderforTempcontrolsthetemperatureoftheaircomingoutofthesystem. Pressandreleaseontheslidertosetthetemperature.TheVintageAirGen‐IV automaticallycontrolstheheatercontrolvalveandtheairconditioningclutchbased onthesettingonthisslider. TheFanslidercontrolsthespeedofthefanontheVintageAirGen‐IVunit.Press andreleaseontheslidertosetthefanspeed.Toshutoffthefan,pressthe0areaon theslider. Figure2:inTOUCHMobileScreencontrolsforHeat&A/C 8 Rev012/2011 SwitchControlfromtheMASTERCELL InadditiontotheinTOUCHMAXandinTOUCHMobilecontrol,youcanuseany switchconnectedtotheMASTERCELLtocontrolthefunctionsofyourVintageAir Gen‐IVsystem.Therearenospecificinputsdefinedforthisinthebase configurationsopleasecontactISISPowertechnicalsupportformoreinformation onthisadvancedfeature. ModePosition ThemodepositionfortheVintageAirGen‐IVcanbecontrolledtwodifferentways. Oneoptionistoassignspecificbuttonstoeachmode:Floor,Vent&Defrost.Youcan alsoassignbuttonsthatblendtheFloor/VentandFloor/Defrost.Anotheroptionis toconnectapotentiometertooneoftheMASTERCELLanalogueinputstogiveyou variablecontrolofthemoderangingfromVent‐Vent/Floor‐Floor‐Floor/Defrost‐ Defrost. Temperature Youcanuseswitchestoincrementanddecrementthetemperatureoftheaircoming fromtheVintageAirGen‐IV. FanSpeed Liketemperature,youcanuseswitchestoincrementanddecrementthefanspeed. Youcanalsousediscreteswitchestosetspecificfanspeeds.Forexampleyoucould have4buttonsthatwouldsetthefanspeedaslow,medium,highandoff. 9 Rev012/2011 WarrantyInformation WarrantyforISIS™IntelligentMultiplexSystem™ Infinitybox,LLC(“Infinitybox”)warrantsagainstanydefectsinmaterialsand workmanshiptotheProduct’sISIS™modules,wiringharnessesandaccessory modulesforaperiodofone(1)yearfromthefirstdateofpurchase.Subjecttothe termsofthiswarrantydescribedbelow,Infinityboxwillreplaceanysuchdefective ProductthatisreturnedtoInfinityboxwithintheone(1)yearperiodfrominitial purchase.ReplacementofanydefectivepartorProductwillnotextendthe applicablewarrantyperiod. Thewarrantydoesnotapplyto:(i)anyProductthatisnotinstalledincompliance withtheapplicableProductdocumentation;(ii)anydefectin,orfailureof,the Productresultingfromanaccident,shock,negligence,waterimmersionormisuse; (iii)anyProductthathasbeenmodified,adjusted,repaired,ordisassembledbyany partyotherthanInfinitybox;or(iv)anydefectotherthaninmaterialsand workmanship. ThiswarrantycoversonlytheoriginalpurchaserofProductpurchasedfroman InfinityboxauthorizeddealerintheUnitedStates.Inordertoreceivewarranty service,purchasermustprovideInfinityboxwithacopyofthereceiptstatingthe dealername,productpurchasedanddateofpurchase.Productsfoundtobe defectiveduringthewarrantyperiodwillbereplaced(withaproductdeemedtobe equivalentorbetter)atthediscretionofInfinitybox. Infinitybox’ssoleliabilityforanydefectiveProductislimitedsolelytothe replacementofProductpursuanttothiswarranty.Infinityboxreservestherightto replaceanyrepairablepartswithneworrefurbishedparts. INFINITYBOXDISCLAIMSALLOTHERWARRANTIES,WHETHEREXPRESS,IMPLIED ORSTATUTORY,SUCHASWARRANTIESOFMERCHANTABILITYANDFITNESS FORPURPOSE.INNOEVENTSHALLINFINITYBOXBELIABLEFORANYPUNITIVE, INDIRECT,INCIDENTALORCONSEQUENTIALDAMAGES,INCLUDINGWITHOUT LIMITATION,LIABILITYFORLOSSOFUSE,LOSSOFPROFITS,LOSSOFPRODUCT ORBUSINESSINTERRUPTIONHOWEVERTHESAMEMAYBECAUSED,INCLUDING NEGLIGENCE. 10 Rev012/2011 ContactInformation TheISIS™IntelligentMultiplexSystemisaproductof Infinitybox,LLC 1‐847‐232‐1991 sales@isispower.com www.isispower.com 11 Rev012/2011
© Copyright 2024