Catalog 1.1.3 Linear Diffuser SAL 35 Dusseldorf Fair Ground, Germany Linear diffuser NAD Klima SAL 35 Model content Description, areas of application and benefits . . . . . . . . . . . . . . . . . . . . . . . . SAL 1 Configuration, mode of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 2 Selection the number of slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 3 Aerodynamic data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 4 Direction of the air flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 5 Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 6 Diagram and example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 7 Dimensions and installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 8 Dimensions of the plenum with side inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 9 Dimensions of the plenum with top inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 10 End cap and connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 11 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL12 Codification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAL 15 1.1.3 SAL 35 C Concordia University, Montréal, Canada Linear diffuser NAD Klima Description, Areas of application and Benefits Linear diffuser SAL 35 The SAL diffuser has linear slots with 35mm profiles. It is composed of extruded aluminum surfaces with ABS eccentric drums which slide inside and are mounted on the plenum. The SAL 35 is available with one or multiple slots depending on the application and the required amount of air. The elements can be mounted one after another to create a diffusion wave. Areas of application - Rest areas with average ceiling heights. Benefits - Adjustable without reducing the speed of the exiting air flow thanks to the section of variable drums. - Areas with levels of elevated and high - Influence (e.g. extension) on the speed air movement. critical airflow trajectory. - Situations where the diffuser must adapt to the contours and colors of the space. - Influence on the method of induction (diffuse mode). - Systems with variable flow. - Adjustment of the penetration of the air jet. - Offices, conference rooms, computer rooms, white rooms, shopping malls, cinemas, theatres etc. - Optional suppression of the Coanda effect. - Change of the direction of the jet. - Reproductive diffusion setting. - Factory default setting. - Adjustment of the diffuser still possible even after installation. - Diffuser settings not reset during cleaning. Subject to technical changes. Version 14 / 04 / 2015 1.1.3 SAL 35 1 NAD Klima Linear diffuser Configuration and mode of operation Controlling the direction of airflow 6 Volume flow F 4 3 1 A min. max. C D E B 5 2 Indexing- range 1/A F/6 6 / 5/ 4 5 3/ 22/ 1 4/3 B B /C C/D E/ F A/ D/E Dire ction of air flow Configuration 1. Extruded aluminum profile 2. Extra-wide or narrow profile 3. Eccentric drums 4. Plenum 5. Air guiding blades 6. Display and adjustment dial. The SAL linear diffuser slots are composed of extruded aluminum (1) with additional wide or narrow profiles (2), the eccentric drums (3), which can rotate 360° and a plenum (4). The eccentric drums (3) offer an acoustic level and optimal aerodynamics, and possess on their axis multiple air guiding planes (5), a display and adjustment dial (6) on which are alphanumeric characters, allowing the user to define and reproduce the drum settings. The profiles, with a powder coated paint are attached to the plenum with the aid of rivets for applications in a suspended ceiling and by central screws for the gypsum ceilings. 2 1.1.3 SAL 35 Mode of operation The eccentric drums form, with the aid of the aluminum air guiding slots a flow of optimal air. The design of approach to the drums causes a drop in pressure as the air enters. As the air leaves the slot it is stable and generates a low level of acoustic power. The flow maintains a powerful induction of ambient air. The positioning of the eccentric drums allows an adjustment of the direction of the air jet, with or without reduction in the exit area. To maintain a dense airflow and maintain the direction of the air flow perpendicular to the axis of the drums, the drums have small plates to guide the air. Mode of operation Adjustment of the air jet direction Thanks to the shape of the eccentric drums and adjustment dial with alphanumeric characters, the direction of the air jet at the outlet of the diffuser can be directed changed up to 180°. For each direction there are two (2) drums positions (“reduced” or “not reduced” positions) as illustrated in the diagram above. The direction of the jet is indicated on the diagram if the diffusers are freely suspended. For a ceiling installation, a horizontal airflow is generated by the Coanda effect with the drums in positions EF, F6, 1A, AB and 21, 32, 54 and 65. The length of the drums can each be adjusted up to 100mm. As a result, the combinations of airflow are almost infinite. During manufacture, the drums are normally set alternately in position 21 and 65 (diffusion mode). This setting produces airflow with a strong induction which can be used even in areas with high cooling needs and mixed air rates. Subject to technical changes. Version 10 / 06 / 2015 NAD Klima Linear diffuser Selection the number of slots Note : To facilitate the selection of the SAL, the total airflow must be calculated for active slot lengths of 1m. 1400 (250) Specifications: Height of the air-duct: Airflow by diffuser: Cooling: Heating: Length of SAL: 1100 (200) 1360 (243) (248) 1300 (235) 1200 (215) H = 3.00 m Vo = 384 m3/h ∆T = - 15°C ∆T = +15°C L = 1500 mm (216) 1190 (213) (217) 1200 (215) 1000 (180) 1020 (186) 900 (160) 900 (160) (162) 1050 (189) 960(176) 850 (155) 800 (140) Research: 1- Airflow by metre of slot section 2- Number of slots n in cooling 750 (135) (cfm/pi.li) 700 (125) . Air flow V [m / h/m] h/m Solution: 1 Each slot of 1500mm = 1.5m of length, which we divide by 1.5 to find the air flow by metre of slot : 324m3/h / 1.5 = 256 m3/h/m The diagram “Number of slots” and in a cooling mode we find the number of slots : n=3 2 600 (110) (108) 500 (90) 510 (92) (93) 450 (81) 400 (72) 340 (62) 300 (55) (54) 300 (55) 1 100 (18) 600 (110) 480 (86) (88) 360 (66) 240 (44) 170 (31) 150 (27) 120 (22) 120 (22) 2 1 Number of slots 720 (132) 680 (122) (124) 600 (110) 200 (36) 840 (154) 2 3 4 5 6 7 . Air Flow by meter of slot of SAL 35 V0 8 m3/h/m / slot (cfm/ li.ft / slot) Cooling only for all ceiling heights Heating and cooling or cooling only for ceiling heights ≤ 3.0 m 50 - 120 (10-22) Heating and cooling or heating only for heights of 3,0 m - 4,5 m 120 - 150 (22 - 27) Heating and cooling or heating only for ceiling heights of 4.5m – 7m * 150 - 170 (27 - 31) * validate the sound level If heating mode cannot be selected for the initial flow in areas with ceiling heights of 3m, reduce the length of the slots Ls to the recommended length. . V . Vmax Angle of the direction of airflow Air volume flow ratio [°] . V . Vmax 3 2 1 Drum position A B C Subject to technical changes. Version 29 / 05 / 2015 D E F 6 5 Outlet airflow The diagram below shows the ratio between the airflow exiting the diffuser and the drum position; the pressure of the system remains unchanged. On the other hand, through an increase of pressure upstream, the speed of exiting air can be noticeably increased while maintaining the same airflow even with the drum in the “reduced” setting. 4 1.1.3 SAL 35 3 NAD Klima Linear diffuser Aerodynamic data ( Slot length Ls = 1 m) V˙ [m / h/m] ∆p [Pa] 345 430 535 6 V˙ [m / h/m] ∆p [Pa] y [m] 9 13 20 370 450 550 13 19 28 3.3 4.3 5.5 400 500 600 8 12 17 435 525 620 13 18 25 3.6 4.6 5.7 7 460 570 680 8 12 16 495 600 710 12 17 24 3.9 5.0 6.2 8 510 635 785 7 11 17 550 650 810 11 16 24 4.1 5.0 6.7 Size [-] LWA [dB(A)] Minimum spacing [m] x crit [m] Specification : The minimum space for a 3m high sub-ceiling with air speeds in the occupied zone should not exceed 0.2m/s Penetration of the vertical jet in heating mode + difference in temperature °C in cooling ∆T = - 8°C: The blue column: Setting the drums to diffuse 1A/F6 (horizontal jet) The red column: Setting of the drum in CD (vertical jet). 4 1.1.3 SAL 35 Subject to technical changes. Version 14 / 04/ 2015 NAD Klima Linear diffuser Controlling the direction of the air jet The setting produces airflow with strong induction which can be adjusted to the cooling or heating needs of the room in areas with high airflow. When all of the drum of the first slot are adjusted to 2 1 and in the second slot are adjusted to 6 5, the adjustment produces a flow in two directions (divergent). The diagrams below illustrate the different relationships between the position of the eccentric drums and the direction of the air jet at the outlet of the drum. Examples of application BC / 6 5 Diffuse DFL BC/EF Diffuse DFE 21/65 Diffuse DFS AB/EF Diffuse DFF Notes : The adjustable side of the drum must be to the left of the collar. BC/65 Diffuse DFL 1.8 m (6 ft) BC/EF Diffuse DFE 1.8 m (6 ft) max. 3 m (10 ft) As a result, the combinations of airflow are almost infinite. For the diffusion mode, the drums must be set alternately to the configuration illustrated in the diagram in positions 2 1 and 6 5. It doesn’t matter if multiple slots are mounted parallel to one another; any airflow or direction of air can be achieved through different drum combinations. max. 4 m (13 ft) Due to the zone of low air pressure and the level of the eccentric drums, the direction of the air flow can be altered by up to 180°. During assembly the NAD label must always be placed on the same side as the collar of the plenum. max. 6 m (20 ft) When the air inlet is on the top or a wall installation, follow the directions on the workshop design. Indexing Range Volume Flow min. max. CD Divergent DVV BC/DE Diffuse DFH CD Divergent DVV 1.8 m (6 ft) Air jet on one side Air inlet collar C D / AB Diffuse DFN C D / AB Diffuse DFN 1.8 m (6 ft) Drums at 2 1 Subject to technical changes. Version 28 / 05 / 2015 Drums at 6 5 1.1.3 SAL 35 5 NAD Klima Linear diffuser Diagrams · Air flow V cfm/pi.li. slot m3/h/m slot V max = V max Diagram *k Drum position 9 7 11 13 14 16 18 Standard 22 27 Number of slot All example All 1A or All F6 CD See example on page 7 1 m3/h/m slot cfm/pi.li. slot 7 · Air flow V Airflow distance after meeting y [m] 9 11 13 14 16 18 22 27 3 Airflow distance x [m] with 1A, F6 (diffuse) 4 x x irfl A x y ymax Vertical : all C D x crit 6 1.1.3 SAL 35 ve , 5 x crit [m] Airflow distance with 1 A, F 6 (diffuse) 6 ow ymax [m] Airflow distance with CD 2 ax yv m it loc Subject to technical changes. Version 29 / 05 / 2015 Linear diffuser NAD Klima Diagram Example Loss of pressure / Level of acoustic power Example Drum position Specifications: - 4 diffusers installed in a series of 3 slots each: SAL 35 - 1500 - 3 - Total airflow : 1535 m³/h - Cooling mode: ∆T = - 15 °C - Heating mode: ∆T = + 15 °C - Width of space: 4m - Length of space: 8m - Height of space: 2.74 m - Head height: 1.8 m CD 21 Research : 1. Air flow by metre of slot 2. Maximum airflow speed in occupied zone Vmax 3. Critical distance in cooling mode Xcrit ? 4. Acoustic pressure LWA ? 5. Loss of pressure ∆P t ? 2. From the sizing diagram, a wall distance x=2m 2 and a trajectory after they meet y=3m – 1.8m = 1.2m, 3 we can find the maximum air speed in the occupied zone of : Vmax=0.25m/s 4 3. For the cooling mode of -15°C, 5 we can determine the critical distance Xcrit = 8.5m 6 4. The acoustic power diagram and airflow by metre of slot of 85m3/h/m we read the acoustic power diagram LWA = 28 dB(a). 7 From the values shown in the table we calculate the level of power generated: LWA = LWA diagram + I = 28+4.7+7.8 = 40.5 dB(A) 40.5 dB(A) - 10 dB(A)= 30.5 dB(A) 5. For an airflow by metre of 85 m³/h/m slot we read: ∆P t = 13 Pa 8 Subject to technical changes. Version 29 / 05 / 2015 8 m3/h/m slot cfm/pi.li. slot · Air flow V et 65 7 Pressure loss ∆p t [Pa] Solution: 1. For a total air flow of 1535m3/h and 4 SAL35 diffusers, we find: 1535 X 4 = 384 m3/h by diffuser. We divide by the number of slots: 384 m³/h ÷ 3 = 128 m³/h. Each slot of 1500mm = 1.5m in length, we divide by 1.5 to find the air flow per metre of slot: 128 m³/h ÷1.5 = 85 m³/h/m 1 5 et )] (A L WA 9 11 Number of slot 1 k [dB] 0.0 13 2 3.0 14 3 4.7 1 4 6.0 18 5 7.0 B [d 22 6 7.8 25 7 8.4 8 9.0 29 9 9.5 10 10.0 How to determine the diffusion length Diffusers installed in parallel The lenght of diffusion: 3 m Diffusers installed in series The lenght of diffusion : 9 m Lenght of diffusion I [dB(A)] 1 0.0 2 3.0 3 4.7 4 6.0 5 7.0 6 7.8 7 8.4 8 9.0 9 9.5 10 10.0 3m 3m 3m 3m Important : The absorption of the room is not accounted for. For a comparison with North American values, reduce the acoustic power by 10. 1.1.3 SAL 35 7 NAD Klima Linear diffuser Dimensions and Installation Wide or narrow diffuser slots made of extruded aluminum surfaces with ABS eccentric drums. 32 32 32 32 35 58 The diffuser is also available with a made to measure steel plate (p.13) Available dimensions L(mm) 300, 400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000 Intermediate dimensions available. One-slot SAL profile with narrow profile A combination of multiple standard lengths allows the creation of a diffuser of the desired length. The connection, which is invisible, is made with pins (p.13). One-slot SAL profile with wide profile 65 65 65 65 68 91 Two-slot SAL profile with narrow profile Two-slot SAL profile with wide profile Mounting and suspension for a gypsum ceiling 3 6 4 C D E B 14 F 1 A 14 5 Attach it with the screws which are provided for this purpose. Suspension of the plenum is achieved with the help of hooks and a threaded rod M4 – M5. (not supplied) 2 The balancing key (optional) is adjustable per the diffuser. Position and fix the plenum and ensure the inlet opening of the diffuser is level with the ceiling, by simply pressing the diffuser inlet. H H ØD Screw to fix the diffuser ØD Spring balancing damper (optional) Gypsum 3 2 B F 6 4 1 A . 58 5 gypsum 5/8” C D E Opening in the gypsum 8 1.1.3 SAL 35 Subject to technical changes. Version 14 / 04 / 2015 Linear diffuser NAD Klima Dimensions Plenum with top inlet and wide profiles SAL 35, 1 row SAL 35, 2-row D D D 50 14 SAL 35, 3 rows and more 50 14 50 14 B Perforated plate H Perforated plate H H Perforated plate B F E 91 PS (with cover profiles) PL (with support profiles) 58 Note: The measurements are indicated in the table on pages 10 and 11 Plenum with side round inlet and wide profiles SAL 35, 2-row SAL 35, 3 rows and more 14 14 B Spring Balancing Damper (optional) B ØD Perforated plate H H H ØD Radial Blade Damper (optional) Grillage 14 ØD SAL 35, 1 row F E 58 90.5 PS (with cover profile) PL (with support profile) Note: The measurements indicated in the table on pages 10 and 11 are for a plenum with the inlet on the side and support profile. Subject to technical changes. Version 15 / 04 / 2015 1.1.3 SAL 35 9 NAD Klima Linear diffuser Dimensions SAL 35, 1-row with plenum Dimensions [mm] Size B Size H from 650 to 900 88 88 286 Size E 286 26 Size F 26 32 Size PS 32 Size Ø D side top Air inlet (Qty) from 950 from 1550 to 1500 to 2000 88 286 26 32 Size B Size H 120 120 120 120 286 342 342 342 342 26 Size E 58 58 58 58 32 Size F 65 65 65 65 68 68 68 68 91 91 91 91 side 150 200 200 200 top 150 (oval) 200 (oval) 200 (oval) 200 (oval) 1 1 1 2 35 58 58 58 58 Size PL 125 125 150 125 125 (oval) 125 (oval) 150 (oval) 125 oval) 1 1 1 2 from 650 to 900 152 152 342 90 96.5 from 950 from 1550 to 1500 to 2000 152 342 90 96.5 from 950 from 1550 to 1500 to 2000 184 184 184 184 342 Size H 392 392 392 392 90 Size E 122 122 122 122 96.5 Size F 130 130 130 130 133 133 133 133 155 155 155 155 side 200 200 250 250 top 200 (oval) 200 (oval) 250 (oval) 250 (oval) 1 1 1 2 98 98 122.5 122.5 122.5 122.5 Size PL side 150 200 250 200 top 150 (oval) 200 (oval) 250 (oval) 200 (oval) 1 1 1 2 Size Ø D Air inlet (Qty) SAL 35, 6-row with plenum from 300 to 600 from 650 to 900 Size B 216 216 216 216 Size H 392 392 392 Size E 154 154 Size F 162 Size PS Size PL 1.1.3 from 650 to 900 Size B 98 from 950 from 1550 to 1500 to 2000 from 950 from 1550 to 1500 to 2000 from 300 to 600 from 650 to 900 Size B 248 248 248 248 392 Size H 392 392 392 392 154 154 Size E 187 187 187 187 162 162 162 Size F 195 195 195 195 165 165 165 165 Size PS 198 198 198 198 188 188 188 188 Size PL 221 221 221 221 side 200 250 302 250 side 200 250 302 250 top 200 (oval) 250 (oval) 302 (oval) 250 (oval) top 200 250 (oval) 302 (oval) 250 (oval) 1 1 1 2 1 1 1 2 Dimensions [mm] 10 from 300 to 600 152 SAL 35, 5-row with plenum Air inlet (Qty) Dimensions [mm] 98 Air inlet (Qty) Size Ø D Air inlet (Qty) Size PS v PL Cote Ø D Size Ø D SAL 35, 4-row with plenum from 300 to 600 96.5 Size PS from 950 from 1550 to 1500 to 2000 Size H 35 90 Size F from 650 to 900 Size B 35 342 Size E from 300 to 600 88 SAL 35, 3-row with plenum Dimensions [mm] Dimensions [mm] Size PS 35 Size PL SAL 35, 2-row with plenum from 300 to 600 SAL 35 Dimensions [mm] Size Ø D Air inlet (Qty) Subject to technical changes. Version 14 / 04 / 2015 Linear diffuser NAD Klima Dimensions SAL 35, 7-row with plenum SAL 35, 8-row with plenum from 300 to 600 from 650 to 900 from 300 to 600 from 650 to 900 Size B 280 280 280 280 Size B Size H 392 392 457 312 312 312 312 392 Size H Size E 219 219 392 392 457 392 219 219 Size E Size F 226 251 251 251 251 226 226 226 Size F Size PS 259 259 259 259 229 229 229 229 Size PS Size PL 262 262 262 262 252 252 252 252 Size PL 286 286 286 286 side 200 250 353 250 side 250 302 353 302 top 200 250 353 (oval) 250 top 250 302 (oval) 353 (oval) 302 (oval) 1 1 1 2 1 1 1 2 Dimensions [mm] Size Ø D Air inlet (Qty) from 950 from 1550 to 1500 to 2000 from 650 to 900 Size B 344 344 Size H 392 392 Size E 283 283 Size F 291 291 Size PS 294 294 Size PL 317 317 side 250 302 top 250 302 1 1 Air inlet (Qty) from 950 from 1550 to 1500 to 2000 SAL 35, 10-row with plenum from 300 to 600 Size Ø D Size Ø D Air inlet (Qty) SAL 35, 9-row with plenum Dimensions [mm] Dimensions [mm] from 950 from 1550 to 1500 to 2000 Dimensions [mm] from 300 to 600 from 650 to 900 from 950 from 1550 to 1500 to 2000 344 344 Size B 376 376 376 376 457 392 Size H 392 392 457 392 283 283 Size E 315 315 315 315 291 291 Size F 334 334 334 334 294 294 Size PS 337 337 337 337 317 317 Size PL 350 350 350 350 353 302 side 250 302 353 302 353 (oval) 302 top 250 302 353 (oval) 302 1 2 1 1 1 Subject to technical changes. Version 14 / 04 / 2015 Size Ø D Air inlet (Qty) 1.1.3 2 SAL 35 11 Linear diffuser NAD Klima Dimensions Total length with end cap (mm) Nominal size PLP/PSP PLL/PLR PL2 PSR/PSL PS2 298 398 497 573 696 795 895 994 1093 1183 1292 1392 1491 1590 1690 1789 1889 1988 313 413 512 588 711 810 910 1009 1108 1198 1307 1407 1506 1605 1705 1804 1904 2003 328 428 527 603* 726 825 925 1024 1123 1213* 1322 1422 1521 1620 1720 1819 1919 2018 300 400 499 575 698 797 897 996 1095 1185 1294 1394 1493 1592 1692 1791 1891 1990 302 402 501 577 700 799 899 998 1097 1187 1296 1396 1495 1594 1694 1793 1893 1992 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 * Dimensions modified for insertion into a suspended ceiling PL2, PLR, PLL 15 mm 15 mm PS2, PSR, PSL 2 mm 2 mm PLP, PSP 12 1.1.3 SAL 35 Subject to technical changes. Version 18 / 06 / 2015 Linear diffuser NAD Klima End caps and connectors PS with narrow profile 2 mm flat end cap 2 mm PS2 : with flat end cap on both sides PSR : with flat end cap on right side PSL : with flat end cap on left side 2 mm PL with wide profile (”L”) End cap in « L » shape 15 mm 15 mm 15 mm PS2: with wide end on both sides PSR: with wide end on the right side PSL: with wide end on the left side APA for the steel plate (made to measure Note : it is essential to write the overall dimensions you need (in mm) of the steel plate in annotation. Connectors (pull pins) Connectors (pull pins) The connection between diffusers is made with the aid of pins (included) when needs indicate that more than one diffuser in length is required. PLL PLP PLR Left Middle Right Subject to technical changes. Version 14 / 04 / 2015 1.1.3 SAL 35 13 NAD Klima Linear diffuser Specifications 1 - Description and physical characteristics 2 - Performance 1.1 The NAD Klima SAL 35 ceiling air diffuser is composed of extruded aluminum blades with one, two or multiple slot combinations. A width of 35mm and with plastic (ABS) eccentric drums in either matte black or white. 2.1 The SAL 35 diffuser assures a strong rate of induction even in highly variable areas in order to maintain an acceptable temperature differential in the air jet. That is to say, the difference between the designated temperature and the temperature of the air projected by the diffuser into the occupied zone. 1.2 The 100mm long NAD Klima eccentric drums are individually adjustable with an alphanumeric codification and can be rotated through 360°. Accordingly the diffuser remains fully adjustable throughout the range of diffusion (in height and through 180°). 1.3 The diffuser is supplied with a wide or narrow profile. 2.2 The performance of the SAL 35 diffuser is guaranteed by a software simulation which indicates the loss of pressure and the acoustic power generated. It also provides a cross-sectional view of the critical trajectory of the air and the nominal speed in the occupied zone in cooling mode, in heating mode and isothermal mode at 1.8m from the ground or at the request of the engineer. 3 - Adjustment 3.1 The diffuser includes a plenum provided by the manufacturer. The plenum is made from 24 gauge galvanised steel and comprises suspension points at the four corners. The inlet collar can be centred on the side and adapted to the air flow. The interior joints of the plenum are sealed with silicon. 3.2 The SAL 35 diffuser includes a perforated airflow stabilizing (equalizing) frontal plate. 4 -Balancing 4.1 The balancing must be executed by a ventilation balancing technician with a recognised professional certification. 4.2 The technician must take into account the factor of correction for the volume of air using a balometer (factor FCB). 5 - Certification 5.1 The linear diffuser SAL 35 meet the standard of ASTME 162 "Surface Flammability of Materials Using a Radiant Heat Energy Source" 6. Required quality : NAD Klima SAL 35 model. 14 1.1.3 SAL 35 Subject to technical changes. Version 04 / 06 / 2015 Conference room, Germany TPSGC, Québec, Canada NAD Klima Linear diffuser Codification Product SAL 35 0300, 0400, 0500, 0600, 0700, 0800, 0900, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000 Number of slots 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 DFS DFL DFH DFE DFF DFN = = = = = = Standard diffuse 21 / 65 Window diffuse B C / 65 Diffuse height BC / DE Diffuse window (max. 4 m) BC / EF Diffuse AB / EF Diffuse CD / AB PL2 = PLL = PLR = PLP = PS2 = PSL = PSR = PSP = APA = DVB DVD DVM DVV DVS DRB = Divergence 21 = Divergence 65 = Wall divergence DE (jet towards the ceiling) = Vertical divergence CD = Divergence 21 / 65 = Divergence with jet nozzles Wide profile with end cap in “L” shape on both sides Wide profile with end cap in “L” shape on left side Wide profile with end cap in “L” shape on right side Wide profile without an end cap (with pins) Narrow profile with flat end cap on two sides Narrow profile with flat end cap on left side Narrow profile with flat end cap on right side Narrow profile without end cap (with pull pins) With a steel frontal plate * (Write the dimensions you need (in mm) in annotation) W = White drums or white nozzles (RAL 9003) C = Cream drums or cream nozzles (RAL 9010) B = Black drums or black nozzles 9003 = 9010 = 00SB = 00SM = _____ = Length of diffuser White Cream Solar black (Standard matte black ) Matte silver (Standard metallic gray ) RAL color (indicate the number of the colour) S = Plenum with inlet on the side T = Plenum with inlet on the top X = Without plenum I = With acoustic insulation A = With closed cell acoustic insulation X = Without insulation F = With fireproof insulation and fireproof dampers X = Without fireproof insulation and fireproof dampers D = With spring damper R = With radial damper ** X = Without damper G = Gypsum ceiling W = Wall X = Suspended ceiling SAL 35 - 0300 - 1 - DFS - PL2 - B - 9003 - S - X - X - X - X Annotation Airflow Profile and end cap Colour of the drums and nozzles Diffuser colour Plenum Acoustic insulation Fireproof insulation Balancing damper Type of installation Example Notes : * For the APA model, it is essential to indicate the overall dimensions of the steel plate you need (in mm), in annotation. ** Not available on oval collar Subject to technical changes. Version 14 / 04 / 2015 1.1.3 SAL 35 17 w w w.na dk l ima. co m NAD Klima 144 Léger St, Sherbrooke Québec, Canada J1L 1L9 • T : 819 780-0111 - 1 866 531-1739 - F : 819 780-1660 • info@nadklima.com
© Copyright 2024