Installation Guide OADM Overview This document provides steps necessary to correctly install and configure Canoga Perkins’ passive OADM product. The passive OADM comes in two configurations: “Drop and Continue” and “Drop and Insert.” Installation Ensure that there is no visible damage to the OADM module and that the OADM module meets the installation requirements. Refer to the Technical Specifications page. The OADM can be installed in either slot of a UCS 1001 or in a UCS 1000. Insert the OADM module in either slot of a UCS 1001 Chassis. Insert the 6702 in the other slot. See figure 1. Figure 1 Drop and continue applications Items required • 1 x Model number OADM-2001-xx03 • 1 x Model number 6702 (Remote wavelength must match the OADM’s dropped wavelength) • 1 x UCS 1001 or UCS 1000 • Singlemode fiber optic jumpers Identify the West Link Tx/Rx fiber pair and East Link Tx/Rx fiber pair. • The West Link Tx/Rx fiber pair is the composite optical signal to and from the central location or West location. • The East Link Tx/Rx fiber pair is the optical signal continuing to and coming from the East site. • Connect the OADM to the link. See Figure 2. Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912425 Rev B Figure 2 • • Using a pair of singlemode fiber optic jumpers, connect the “West 1xxx” port to the Remote Tx/Rx port of the 6702 CWDM transponder. Connection of the ports must be Tx to Rx. See Figure 3. Figure 3 The wavelength listed on the Remote Tx/Rx port of the 6702 must match the wavelength listed on the “West 1xxx” port of the OADM. Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912425 Rev B Drop and insert applications Items required • 1 x Model number OADM-2002-xx03 • 2 x Model number 6702 (Remote wavelength must match the OADM’s dropped wavelength) • 2 x UCS 1001 or 1 x UCS 1000 • Singlemode fiber optic jumpers Identify the West Link Tx/Rx fiber pair and East Link Tx/Rx fiber pair. • The West Link Tx/Rx fiber pair is the composite optical signal to and from the central location or West location. • The East Link Tx/Rx fiber pair is the optical signal continuing to and coming from the East site. • Using a pair of singlemode fiber optic jumpers, connect the “West 1xxx” port to the Remote Tx/Rx port of the 6702 CWDM transponder communicating to the West Link. • Using another pair of singlemode fiber optic jumpers, connect the “East 1xxx” port to the Remote Tx/Rx port of the 6702 CWDM transponder communicating to the East Link. • Connection of the ports has been color coded in figure 4 to depict the fiber optic jumper connections. See Figure 4. Figure 4 The wavelength listed on the Remote Tx/Rx port of the 6702 must match the wavelength listed on the “West 1xxx” and “East 1xxx” port of the OADM. Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912425 Rev B Technical Specifications Drop and Insert WDM Type Number of Filters Number of Channels Channel Wavelengths Center Wavelength Accuracy Passband @ 0.5dB Insertion Loss Drop Channel Passing Channels Adjacent Channel Isolation Non-adjacent Channel Isolation Uniformity Directivity Optical Input Return Loss PDL PMD Thermal Stability, Loss Thermal Stability, Drift Optical Power Capacity Storage Temperature Operating Temperature Termination Multilayer Thin Film Optical Filter 2 Mux / 2 Demux Single Channel Drop & Insert 1310,1470,1490,1510,1530,1550,1570,1590,1610nm ±1.0nm >14nm, <17nm Mux Demux ≤1.6dB ≤1.6dB ≤1.6dB >30 Demux >40 Demux <1.5dB >50dB >45dB <0.1dB <0.1ps 0.005dB/°C 0.005nm/°C ≥300mW -40 ~ 85°C 0 ~ 70°C Local Channels: SC/UPC; Composite: SC/UPC Drop and continue WDM Type Number of Filters Number of Channels Channel Wavelengths Center Wavelength Accuracy Passband @ 0.5dB Insertion Loss Drop Channel Passing Channels Adjacent Channel Isolation Non-adjacent Channel Isolation Uniformity Directivity Optical Input Return Loss PDL PMD Thermal Stability, Loss Thermal Stability, Drift Optical Power Capacity Storage Temperature Operating Temperature Termination Multilayer Thin Film Optical Filter 1 Mux / 1 Demux Single Channel Drop & Insert 1310,1470,1490,1510,1530,1550,1570,1590,1610nm ±1.0nm >14nm, <17nm Mux Demux ≤1.0dB ≤1.0dB ≤1.0dB >30 Demux >40 Demux <1.5dB >50dB >45dB <0.1dB <0.1ps 0.005dB/°C 0.005nm/°C ≥300mW -40 ~ 85°C 0 ~ 70°C Local Channels: SC/UPC; Composite: SC/UPC Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912425 Rev B Physical Dimensions 7.9”H x 1.0”W x 10.4”D (201 x 25 x 264mm) Weight 1.2lb (.54kg) Regulatory Compliance UL 60950/CSA C22.2 IEC 60950 IEC 60825-1 FCC Part 15 Class A CISPR 22 EN 50082-1 AS/NZS 3548 NEBS Level 3 CE Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912425 Rev B Warranty Information Current Warranty information is available on-line in the Client Login Area of the Canoga Perkins web site (www.canoga.com) or by contacting Technical Support at 800-360-6642 (voice) or fiber@canoga.com (email). Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912425 Rev B
© Copyright 2024