01 Finishes, Fixtures and Fittings Schedule Rev 2

TECHNICAL REFERENCE SHEET
(TRS)
#
Project:
503085 - Leichhardt Park Aquatic Centre, Lilyfield
Date
13.03.2015
07.04.2015
Issue
Tender Issue - Rev 1
Tender Addendum - Rev 2
13.03.2015
Project:
Client:
503085 - Leichhardt Park Aquatic Centre, Lilyfield
Leichhardt Park Aquatic Centre
Notes
This legend and schedule is to be read in conjunctions with the Specification and all other contract schedules.
All painted surfaces to be Dulux, unless otherwise stated.
Aluminium skirtings are to be powdercoated, unless otherwise stated.
All window and glazing framing systems to be Dulux powdercoat PPC-*, unless otherwise stated.
Issue: 2
Date:07.04.2015
Refer to the Specification for detailed information of all finishes.
Code
TRS Description
Spec
Ref
BL-01
Access & Safety
Equiptment
Balustrade
05-800
Galvanised steel balustrade and nominal Ø40mm
handrail mounted to floor / stair tread. With galvanised
steel kickplate 150Hx5THK offset 200mm AFFL.
Paint finish - PCC-09.
Ø15mm galvanised steel rod infill balusters at max
125mm cts.
Refer Architectural documentation for extent and details.
Must comply with BCA and AS1428
HR-01
Hand rail
05-800
Nominal Ø40mm handrail mounted to wall - fixings to
match handrail finish.
Stainless steel 316, linished finish.
Refer Architectural documentation for extent and details.
Must comply with BCA and AS1428
HR-02
Hand rail
05-800
Nominal Ø40mm handrail mounted to floor - staunchions
and fixings to match handrail finish.
Stainless steel 316, linished finish.
Refer Architectural documentation for extent and details.
Must comply with BCA and AS1428
Spec Description
Location
Comments
Rev
Access Panel
AP-01
Ceiling access panel plasterboard
05-050
Ceiling access panel to suit suspended plasterboard
ceiling. Sizes as nominated on the drawings, 600 x
600mm typical. Flush finish. Finish to match ceiling
finish. No perimeter trims. Refer to the drawings for
locations.
Refer to RCP for extent.
Coordinate with Mechanical &
Electrical drawings.
Allow access panels for under
Roller Door motors
AP-02
Ceiling access panel Compresses Fibre
Cement Sheet
05-050
Ceiling access panel to suit CFC sheet ceiling. Sizes as
nominated on the drawings, 600 x 600mm typical. Flush
finish. Finish to match ceiling finish. No perimeter trims.
Refer to the drawings for locations.
Refer to RCP for extent.
Coordinate with Mechanical &
Electrical drawings.
Allow access panels for under
Roller Door motors
EM-01
Carpet
Entrance Matting
05-550
CS CONSTRUCTION GROUP
Type: Recessed PediTred G4
Colour: Monotuft 'Graphite'
Finish: Clear Anodised
CP-01
Carpet tiles
05-550
INTERFACE Microtuft Patterned Level Loop Pile
Style : Flatweave
Style Code : Fusion 1543
Code: 1543-001-000
Colour: Hybrid
Backing: GlasBac
Size: 50cm x 50cm x 4.5 mm +/- .5mm
Installation method: Quarter turn
LTS Office
CE-01
Ceilings
Ceiling Type - Fixed
Plasterboard PB-01
05-050
BORAL PLASTERBOARD
Thickness: 13mm with 600mm min. fixings
Flush jointed tape joints
Paint Finish.
Rondo P50 joints at edges.
Refer to RCP for extent and
location.
CE-02
Ceiling Type - Fixed
Plasterboard PB-03
05-050
BORAL
Fibre Cement Sheeting
Flush jointed tape joints
Paint Finish.
Rondo P50 joints at edges.
Refer to RCP for extent and
location.
CE-03
Ceiling Type - Fibre
Cement - FC-02
05-050
BORAL
Fibre Cement Sheeting
Thickness: 9mm with 600mm min. fixings
Express jointed
Paint Finish.
Feature Ceiling in Change
rooms and pool hall.
CE-04
Ceiling Type - Acoustic
panel
05-050
One layer Heradesign Superfine 25mm 1200x600 on
Knauf furring channels. Instalation to suit tecnical
processing guidlines.
Colour TBC.
Cornice
CN-01
Cornice - Shadow-line
05-050
RONDO BUILDING SERVICES
P50 10mm shadowline stopping angle. Set flush.
CN-02
Cornice - Square Set
05-050
RONDO BUILDING SERVICES
Square Set
Concrete finishes
2
CON-01
Worked concrete finish - 03-300
power
Power floated concrete finish. Suitable for vinyl and
carpet finishes by other trades. Flatness of 3mm over
3metres.
CON-02
Worked concrete finish - 03-300
hand
Worked concrete finish - 03-300
broom
Hand trowelled concrete finish. Suitable for tiled
surfaces.
Broom finish concrete to external pavement/concourses.
CON-04
Concrete stair finish
03-300
SC-01
Concrete sealer
05-600
80mm Granolithic concrete screed forming stair treads,
risers and landings.
SIKA
Sikafloor Curejard 24.
Dust-proofer / sealer / hardener: a one part, clear liquid
based on sodium silicate to cure, harden and seal fresh
or hardened concrete.
SC-02
Polysoft
05-500
VERSATEX Standard non-pourous over approved hard
surface and 'polysoft primers'. with 100mm integral
monotek coving to wall and floor junctions.
Colour: Ash 50%, Granite 50%, Granite tinting.
Supply and Install by approved installer with consultation
from Polysoft prior to install.
Methodolgy: In accordance with "Polysoft Versatex
Specifications"
SCR-01
Screed - Pool
Concourses and pool
amenities with applied
Polysoft finish
05-300
Light nylon broom finish. Surface must be clean and free
of contaminants such as grease, dirt and existing
unsound coatings. This is to be checked and cleaned by
contractor.Concrete surface must be acid etched shot
blast or diamond grind to remove any contaminants and
achieve a finish to enable a mechanical bond between
substrate and primer. If a curing agent has been used
the surface must be checked for compatibility (test for
adhesion) or removed prior to installation. In an open
area cut a small groove in the concrete along the
finishing line to anchor the broadcast at that point.
SCR-02
Screed - General wet
areas
05-300
General screed (Bonded)
Generally to tiled areas
Supply and install tiling screed to floors in wet areas and
where indicated on the drawings. The screed mix shall
be plant prepared granolithic concrete screed to 32Mpa
minimum strength. Screeds shall be placed over
structural concrete where specified. The granolithic
screed shall NOT be less than 35mm
Spread the screed mix to specified falls and cross falls,
compact and float to the required tolerance and as
required for the specified surface finish. The surface
shall be prepared and a coat of commercially
manufactured and compatible bonding agent shall be
applied prior to the granolithic screed being placed.
Install waterproof membrane to top of screed to falls.
Membrane shall be PCI Seccoral 2K” flexible acrylic
based liquid. To be applied to the base and sides of all
wet areas shown and/or specified and extended full
height up all adjacent walls, and to be applied to the full
extent of ALL tiled wall faces, all in accordance with the
manufacturer's instructions.
CON-03
Generally to Pool hall LTS
reception.
Builder must supply warranty of
2 years against failure and
cover supply and installation of
the material.
2
EJ-02
Expansion /
Expansion Joint Cover
03-300
LATHAM
Floor expansion joint cover - Stainless steel.
CS-25 Ultimate Series.
Including VWS Water Gutter.
Generally to all expansion
joints to structural slabs where
a surface lining is applied.
Refer to Structural Engineers
Drawings for location(s).
EJ-04
Expansion Joint Cover
03-300
LATHAM
Floor-to-wall expansion joint cover - Stainless steel.
SAS-25 (SSSM 104) Ultimate Series.
Including BFG Water Gutter.
Generally to all expansion
joints to slabs/walls where a
topping slab is applied. Refer to
Structural Engineers Drawings
for location(s).
TM-01
External Cladding
Biowood Wood - Plastic
composite
04-203
BIOWOOD
WP.01.150.18 Shiplap cladding to be laid horizontally
Fixing method: Liquid nails and screw fix to substrate in
accordance with installation guide
Coating: 2 coats intergrain 'Grey' in accordance with
technical specification
Panel joints:
Thickness:18mm
Colour: Weather Wood
Refer to elevations for extent
and panel sizes.
The Manufacturer's Warranty
shall be for 15 years.
The installation is to be carried
out by the manufacturer
representative's approved
installers only.
04-203
BIOWOOD
S4SO05050 Side 4 Side Outdoor 50x50 battens with
internal aluminium stiffening rods
Fixing method: Liquid nails and screw fix to substrate in
accordance with installation guide
Coating: 2 coats bioseal / intergrain
Panel joints:
Thickness:50mm
Colour: Weather Wood
Refer to elevations for extent
External concourse pergola, and window awnings 2
and locations
where shown.
The Manufacturer's Warranty
shall be for 15 years.
The installation is to be carried
out by the manufacturer
representative's approved
installers only.
TM-02
Biowood Wood - Plastic
composite
Glass & Frame Types
GL-01
Clear glass - Double
glazed
04-500
VIRIDIAN
PerformaTech Clear (#2) 6 toughened glass + 12mm
argon + 6mm VFloat toughened Grade A Safety glass.
U-value 1.4
SHGC = 0.38
Glazier to undertake their own assessment of size,
thickness and for thermal breakage / fracture (heat
treatment). All glazing to AS1288-2006 and BCA.
Generally to pool hall and
family change area
GLD-01
Decal film on glazing
04-500
Glazing Decals to AS1288.
Continuous, repeated opaque symbol / logo.
Min. 100mm high band.
To all full width of glazing.
Logo to be provided by Principal.
Refer to Window schedule for
extent.
GF-01
Glazed Framing System 04-500
REYNAERS
Reynaers CW-50 Single Glazed
150mm x 50mm front glazed suite.
Finish: Powdercoat
Internal:
Dulux – PN2E1 “Vivid White”
External:
Dulux PG1F7 – “Western Myall”
Typical glazing frame to
external and internal facade.
GS-01
Colourback Glass
Colourback Glass. All edges to be polished.
Colour to match PT-0*
kitchen benches generally
06-202
Insulation
IN-01
Thermal insulation (roof - 04-203
less than 5 degree pitch)
CSR BRADFORD
CSR Bradford Anticon 140 Roof Blanket, Rm3.3, 140mm
thick, 13.5kg/m3 Glasswool bonded to medium duty
silver reflective foil.
Installation: in combination with CSR Bradford Ashgrid
Roof Spacer 120mm high (20mm sag in safety wire
allows blanket to recover to full thermal performance of
140mm).
R-Total roof solution of Rt3.7 Winter and Rt4.0 Summer.
IN-02
Thermal insulation (roof - 04-203
box gutters)
CSR BRADFORD
CSR Bradford Anticon 55 Roof Blanket, Rm1.3, 60mm
thick, 11.0kg/m3 Glasswool bonded to medium duty
silver reflective foil together with CSR Bradford Dow
Thermax-Light Duty Rm2.9, 63.5mm thick PIR Board
with silver facing.
Installation: Anticon blanket to be laid over gutter support
strapping with foil facing down. Thermax Board cut to
size and installed belowand to sides of gutter prior to
installation of box gutter.
R-Total roof solution of Rt3.7 Winter and Rt4.0 Summer.
IN-03
Thermal insulation
(external walls)
CSR BRADFORD
CSR Bradford Gold Wall Batts, Rm2.5, 90mm thick, High
Performance, 22.0kg/m3 Glasswool together with CSR
Bradford Enviroseal Proctor CW (Commercial Wall)
Breather sarking, non-reflective wall wrap.
Installation: Insulation installed between metal studs and
continued up to underside of roof insulation so to fully
encapsulate thermal envelope. Wall wrap to be fixed to
outside of stud frame, lap 150mm and tape all joints;
repair any damage and tape around all penetrations.
R-Total external wall solution of Rt2.8 Winter.
IN-04
Thermal/acoustic
05-100
insulation (internal walls)
CSR Bradford
Partition Wall Batts 165, Rm3.5, 165mm thick,
11.0kg/m3 Glasswool batts.
Batts installed between studs to walls that require a
reduction in noise transfer.
Internal 150mm steel stud walls
- Acoustic solutions to comply
with acoustic engineer’s report
IN-05
Ceilings - general
05-050
CSR Bradford
Building Blanket 80, Rm1.8, 80mm thick, 11kg/m3
Glasswool at 1200wide. Blanket rolled out over
suspended ceiling system prior to installation of sheet
plasterboard or modular ceiling tiles.
Refer Architectural documents.
05-100
Joinery Finishes
JC-02
Joinery - Component
06-202
HAFELE
Stainless Steel Handle
140mm wide x 35mm high
Cat No: 109.32.902
Colour: Anodised Aluminium
LTS Office area joinery
JCP-01
Joinery - Compact
Laminate
06-202
LAMINEX
Colour: Laminex Polar White Flint Finish
LTS Reception
JL-01
Joinery - Laminate
06-202
LAMINEX
Colour: Laminex White Natural finish. 200
LTS Office area joinery
JL-02
Joinery - Laminate
06-202
LAMINEX
Colour: Laminex Steel Blue, Natural finish.
LTS Office area under bench
JL-03
Joinery - Laminate
06-202
BENCH TOP CITY
Range: Admira
Colour: Azure Linen
(2440 x 1220)
Joinery - Part Reception
JO-01
Opal Acrylic
06-202
Opal acrylic diffuser to face of concealed LED lighting
2
JSK-01
Skirting
06-202
JTM-01
Joinery – Bench Seating 06-202
100mm high natural anodized aluminium flat.
Skirting to all joinery as noted
on drawings
NUVEX
19mm Nuvex Slotted Bench Seating with 316 stainless
steel frame and mounting brackets. Linear slots.
Install new top max. 440mm AFFL to suit locker plinth
450mm AFFL.
Colour: Pure White.
Frame (where floor mounted): 38x38 SHS 316 polished
Stainless Steel Frame Frame (where wall mounted):
440x12mm custom satin stainless wall brackets with
38x38 SHS 316 Satin Stainless Steel stiffeners/framing
as required. Refer to Architectural drawings.
Foot: Castors & Industrial Products AF 31/40/M10/60
40xM10 500Kg 'A-Justa-Foot' with custom fabricated.
Typical Bench seating in
changerooms either floor
mounted or wall mounted.
Refer architectural drawings.
COLT
Colt louvre system: Ventilation and Rain Defence
Louvre.
Series: ERD.
Maximum blade span: max. 1250mm.
CAPRAL
Capral 89mm Louvre
Finish: Powdercoat PPC-12 (to match glazing frames).
Fixed aluminium louvre to be fitted to Capral 419 Series
frame.
REYNAERS
Finish: Powdercoat PPC** (to match glazing frames).
Refer to elevations and louvre
schedule for location. Generally
to upper level facade.
Louvres
04-500
LV-01
Louvres - Plant Screen
LV-02
Fixed Aluminium Louvres 04-500
LV-03
Operable Glazed
Louvres
04-500
Refer to Architectural
Elevations and to Architectural
and Mechanical Louvre
Schedule for locations.
Refer to Architectural
Elevations and to Architectural
and Mechanical Louvre
Schedule for locations.
Masonry
BLK-01
Face blockwork
03-650
BORAL
150 Series (140mm) Standard Natural Block - concrete
blockwork.
Colour: Charcoal
BLK-02
Fire rated blockwork
03-650
Refer to wall types for extent.
BORAL
190mm block work to achieve a 120/120/120 Fire Rating
(Boral Scoria Blend or similar).
Reinforced and core filled where nominated by the
structural engineer.
BLK-03
Polished faced blockwork 03-650
Refer to wall types for extent.
BORAL
Series 150 Designer Block (140mm thickness)
Finish: Random pattern, even spread of smooth, Shot
Blast, Honed
Structural: Core fill blockwork with N32 concrete. N20
bar reinforcement tied into the slab / strip footing. Refer
also to Engineers details.
Colour: Charcoal
Mortar: Allow for coloured mortar. Colour TBC. Mortar
mix shall be cement, lime and sand as specified, with
proportions to AS 3700 and AS 1316.
Sealing: Seal blockwork with Duramax MAXISEAL
premium clear sealer from DURAM INDUSTRIES
BLK-04
Polished faced blockwork 03-650
Refer to wall types for extent.
BORAL
Series 150 Designer Block (140mm thickness)
Finish: Random pattern, even spread of smooth, Shot
Blast, Honed
Structural: Core fill blockwork with N32 concrete. N20
bar reinforcement tied into the slab / strip footing. Refer
also to Engineers details.
Colour: Pearl Grey
Mortar: Allow for coloured mortar. Colour Pearl Grey
Mortar mix shall be cement, lime and sand as specified,
with proportions to AS 3700 and AS 1316.
Sealing: Seal blockwork with Duramax MAXISEAL
premium clear sealer from DURAM INDUSTRIES
BLK-05
Face blockwork
03-650
BORAL
200 Series (190mm) Standard Natural Block - concrete
blockwork.
Colour: Charcoal
Paint / Clear / Renders
Finishes
PAA-**
Acrylic Paint - Blockwork 05-600
DULUX
DULUX AcraTex 955 AcraShield
Specification No: AUSA2957
(new blockwork - internal & external).
Refer to wall types for extent.
Refer to wall types for extent.
PAB-**
Acrylic Paint - Concrete
05-600
DULUX
DULUX AcraTex 955 AcraShield Low Gloss - 501/2
AcraPrime
Specification No: AUSA5627
(new concrete colour finish - internal & external)
PAC-**
Acrylic Paint - Interior
ceilings
05-600
DULUX Wash and Wear 101.
Flat Acrylic. DULUX spec AUSD0001.
(plasterboard ceilings - internal & dry)
PAD-**
Acrylic Paint - Interior
walls
05-600
DULUX Wash and Wear 101.
Advanced Low Sheen Acrylic. Plasterboard - DULUX
spec AUSD0002.
(plasterboard walls - internal & dry)
Refer to Finishes schedule and
internal elevations
PAE-**
Acrylic Paint - External
FC
05-600
DULUX
AcraTex 955 AcraShield
Specification No: AUSA0900
(cfc / villaboard ceiling & walls - external)
Refer to Finishes schedule and
internal elevations
PCA-01
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule A
*Preparation and painting of all new exposed mild steel
sections.
PCB-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule B
*Preparation and painting of all new hidden mild steel
sections.
PCC-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule C
*Preparation and painting of all new internal concrete
floor surfaces
PCD-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule D
*Preparation and painting of all new galvanized steel, on
site, in-situ
PCE-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule E
*Preparation and painting of all new steel sections, on
site, in-situ
2
PCF-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule F
*Preparation and painting of all new steel sections, on
site, in-situ (Knauf)
2
PES-**
Paint - Enamel Semi
gloss
05-600
DULUX
Aquanamel Semi Gloss.
PPC-**
Powdercoat
05-600
DULUX Powdercoating.
For Aluminium: Dulux Duratec X15. Refer DULUX
Specification: AUSP5617.
For Galvanized Steel: Dulux Duralloy FG. Refer DULUX
Specification: AU_DP01827.
PTM-**
Timber finish - natural
stain - clear, matt to low
sheen finish
05-600
DULUX. Intergrain Natural Stain. Refer to DULUX spec
AUSW3901. (External timber)
PT-01
Wall Paint finish
Generally
05-600
Colour: Dulux Wash and Wear Low Sheen Water Based Walls generally
Acrylic
Colour: Natural White PN1E1
PT-02
Ceiling Paint fnish
generally
05-600
Dulux Professional Tintable Ceiling Flat
Colour: Natural White PN1E1
Ceilings Generally
PT-03
Ceilings and Walls - Wet 05-600
areas
Dulux Mouldshield "Wash and Wear Bathroom Ceiling
Flat" Water Based Acrylic
Colour: Natural White PH1E1
Bathroom and Wet area
ceilings and part walls
PT-05
Trims Paint Finish 05-600
Skirtings/ Internal Doors/
Door Frames.
Dulux "Wash and Wear" Semi Gloss Water Based
Acrylic
Colour:
PT-06
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Lagoona Teal P30H3
Feature Ceiling and Walls
PT-07
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Santorini P33H3
Feature Ceiling and Walls
PT-08
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Rollercoaster P35H6
Feature Ceiling and Walls
PT-09
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Shimmer P35H1
Feature Ceiling and Walls
Plasterboard/ Linings
2
PB-01
Plasterboard
05-100
CSR GYPROCK
13mm plasterboard with recessed edges. Flush jointed.
Paint finish.
Refer to Wall / Ceiling types
PB-02
Plasterboard Fireboard
05-100
CSR GYPROCK
16mm Fyrcheck plasterboard
Paint Finish
Refer to Wall / Ceiling types
PB-03
Plasterboard Multiboard
05-100
CSR GYPROCK MULTIBOARD
13mm multiboard plasterboardwith recessed edges.
Flush jointed. Paint finish.
Refer to Wall / Ceiling types
FC-01
Fibre Cement
05-100
Refer to Wall / Ceiling types
JAMES HARDIE VILLABOARD
9mm Flush jointed with recessed edges.
Paint finish surface. Allow for 12 Dulux Colours (PAE-**)
Use perforated paper reinforcing tape, embedded in
James Hardie base and top coat jointing system.
Support eaves as required given the wind classification
for the site.
FC-02
Cladding Compressed
Sheet - with expressed
joints
05-100
JAMES HARDIE
Proprietary James Hardie 9mm Versalux system, but on
proprietary ExoTec® Gasket Snap Strips with bubble
gaskets.
Provide 10 mm expressed joints refer to elevations for
details
screw heads covered by epoxy and James Hardie Base
Coat over
Apply a continuous 6mm diameter bead of polyurethane
sealant to the backing strips.
Installation in accordance with James Hardie Exctec
installation recommendations / requirements.
Paint finish surface (PAE-**) Colours to be confirmed
FC-03
Fibre Cement - External
Soffits
05-050
Refer to RCP for locations
JAMES HARDIE VILLABOARD
6mm Flush jointed with recessed edges.
Paint finish surface. Allow for 12 Dulux Colours (PAE-**)
Use perforated paper reinforcing tape, embedded in
James Hardie base and top coat jointing system.
Support eaves as required given the wind classification
for the site.
04-204
EVERBRIGHT
Everbright E610 polycarbonate cladding system installed
vertically.
74mm thick wall panels
Colour:Clear
All trims, flashings, etc. to be powdercoated - PPCDulux PG1F7 – “Western Myall”
Installed with proprietary seals, fixings, trims, etc to
manufacturer's current written specification, by trained,
licensed and approved installers.
Generally to Pool Hall walls
and feature ceiling
Refer to Elevations for paint set
out.
Refer to ACCEL Technical
Supplement “Lining an Indoor
Swimming Pool Area” – edition
36 2012
Polycarbonate
PLC-01
Polycarbonate wall
system
Resilient Materials
FL-01
Flashings
04-203
Refer to Roof plans for
COLORBOND
locations
Folded 0.8mm flashings formed from sheet material
equal to type MT-01 metal roof cladding. Allow for up to
8 folds in flashing.
Finish: *******
*All flashings to be weather sealed at laps and along the
full length by an unbroken bead of 6 x 4mm thick butyl
rubber sealant tape
*(Kingspan reference S-EXT).
*All internal flashings to be made from 0.55mm thick
steel substrate, to the same specification as the liner
sheet of the panel.
*All flashings to have butt straps and sealed with two
unbroken runs of 6 x 4mm thick butyl rubber sealant
tape.
*End laps to be air sealed with gun grade sealant.
*All primary fasteners must be the high threaded type,
manufactured from Austenitic Grade 304 stainless steel
fasteners and fitted with a 19mm diameter bonded
stainless steel washer. All Fasteners MUST be fixed
through the Crown of the panel only. To comply with
local wind requirements, it may be necessary to provide
additional fixings in areas of high local suction.
*Side laps and external flashings to be stitched at
450mm centres (maximum) with carbon steel stitching
screws, complete with bonded 14mm diameter carbon
steel washers.
*Internal flashings to be stitched at 450mm centres with
Austenitic Grade 304 stainless steel fasteners or rivets
and fitted with a 14mm diameter bonded stainless steel
washer.
FL-02
Roofing - penetration
flashings
04-203
DEKTITE
EDPM proprietary flashing
FL-03
Parapet / fascia capping 04-203
Folded parapet capping formed from sheet material
equal to type MT-** metal roof cladding.
FL-04
Custom sharknose
fascia capping
Folded fascia capping formed from sheet material equal
to type MT-01 metal roof cladding. Allow for min. 7 folds
04-203
2
FW-01
Floor Waste
06-203
M A GRIFFITHS
MAG-MIFAB BS1100-R. Product code: Ass. No. 70100
• e: 100mm diameter grade 316 stainless steel.
• Strainer secured to body section with anti-vandal
stainless steel counter sunk screws.
FW-02
Trench Drain
06-203
ACO POLYCRETE (or acceptable equivalent)
Grade 316 stainless steel trench drain (custom
fabricated to all showers with flanges to all sides for
membrane adhesion. Submit shop drawings.
• System trough with safety edge and tile flange.
• Base of drain to have 1:100 fall.
• Outlets are to be located a minimum of 200mm from
the cubical walls to allow cleaning access.
Number of outlets as per the Hydraulic Engineer's
drawings.
• Grade 316 stainless steel waste baskets.
• Heelguard™ grade 316 stainless steel class A antislip
grates.
• Finish: Pickle passivated.
BG-01
Box gutter - Proprietry
04-203
Refer to Roof Plan for location
KINGSPAN
Proprietary Kingspan membrane lined insulated Box
gutter. In maximum lengths and welded joints.
External weather sheet: substrate to be minimum 0.6mm
pre-galvanized coated steel to AS1397 with IKO 0.6mm
or IKO 1.2mm thick PVC membrane.
Insulation Core: consist of 60 or 120mm thick, closed
cell, CFC and HCFC Free FM certified polyisocyanurate
(PIR) insulation. Insulation core bonded to the external
and internal sheets during manufacture.
Internal Liner sheet: Substrate to be 0.5mm to 0.7mm
thick steel S220GD+ZA hot-dip zinc/aluminium coated
steel to AS1397. Coating to be Kingspan Aquasafe
standard bright white.
BG-02
Box gutter - Generally
04-203
Refer to Roof Plan for location
COLORBOND
Colour: **
Box gutters to be made from 0.80mm folded colorbond
steel sheet to the sizes nominated on the hydraulic
engineers drawings.
Allow for associated Lysaght Spandek gutter board,
gutter brackets, outlets, expansion joints, etc.
Sumps to be made from the same material as above to
the sizes nominated on the hydraulic drawings.
Where Spandek gutter board and brackets are exposed
allow to fully paint with system nominated within the
specification for painting over galvanised surfaces.
DP-01
Roof Downpipes
04-203
COLOURBOND DOWNPIPES
Material: refer Hydraulic Engineer.
Shape: round.
Size: 150mm typical – refer Hydraulic Engineer.
Colour: ***
EG-01
Custom Sharknose
Profile Eaves gutter
04-203
Custom sharknose profile eaves gutter, formed from
sheet material equal to type MT-01metal roof cladding.
Allow for min 7 folds
EG-02
Eaves gutter
04-203
100mm quad eaves gutter - colour to match adjacent
wall cladding
MT-01
Metal roof cladding Refer roof plans
04-203
Refer to Roof Plan for location
KINGSPAN
KS1000 RW/FM Trapezoidal Roof System.
With liner substrate to be 0.5mm thick steel S220GD+ZA
hot-dip zinc/aluminium coated steel to BS
EN10214:1992. Internal coating to be Kingspan
Aquasafe standard bright white. High Humidity internal
and Standard (non-corrosive) external environments.
Thickness: 100mm core thickness; 135mm overall
thickness.
Colour: Gull Grey (top side), Off White (underside).
Sealant: Bostik 5250 preformed mastic tapes.
Select system to suit marine environment.
Grade 304 stainless steel fixings.
MT-02
Metal roof cladding Refer roof plans
04-203
LYSAGHT
Colorbond 0.48 BMT.
Blue Scope Lysaght 'Klip Lok'.
Colour:**
Refer to Roof Plan for location
MT-03
Metal Internal parapet
cladding
04-203
LYSAGHT
Colorbond 0.48 BMT.
Blue Scope Lysaght 'Spandek.
Colour: **
Generally to the roof side of all
parapets.
OF-02
Roof - Overflow outlets
04-203
Horizontal overflow through facade.
Shape: Rectangular - typical nom. 300mm wide x 80mm
high.
Size: refer Hydraulic Engineer for confirmation of size.
To match adjecent wall cladding.
SK-01
Aluminium Skirting
05-100
Aluminium clear anodised
Height: 100mm
2
Refer to Finishes Schedule for
locations
RE-01
Resilient Materials - Vinyl 05-500
Store - A.GF07
FORBO Surestep Original
Product: Original
Colour: Elephant
Code: 171952 Thickness: 2mm
Slip Resistance: R10/Barefoot for wet areas
Alll welded joints in accordance with manufacturers
current written installation instructions, to match selected
colour
Stair Nosings
SN-01
Stair nosing - Concrete
stairs
06-150
LATHAM
Asbraloy Safety Stair Tread Nosing.
Profile: Asbrabloy FA711ST 1428.1-2009 Compliant.
Insert colour: Lumo Luminescent
Position: Stair Tread
Fixing: as per manufacturers recommendations
*To comply with AS1428
Generally to all Concrete Stairs
05-400
CTA AUSTRALIA
PolyStud Plastic Tactile Indicators
Code: TSS002-PP-160
8mm dia x 20mm Drill&Lock Fixing Spigot
Textured top surface and smooth side face.
Style: Spiral top surface.
Comply with AS1428.4.
Generally located at the base
and landing of stairs and ramps
in general public areas and
back of house areas. Refer to
plans for locations.
Tactile indicators
TI-01
Tactile ground surface
indicators
Threshold Strip
TS-01
Threshold Strip
06-150
RAVEN
RP96 Anodised aluminium.
Threshold strip. Screw fix to manufacturer’s
recommendations.
Generally to all external doors
and or where flooring material
changes.
TL-01
Tiles / Pavers
Floor Tiles
05-400
TILES EXPO
Type: Fully vitrified ceramic tile
Colour: Geostone Grigio Natural
Slip Resistance: is R11/B
Size: 600 x 300mm x 10mm
Floor tiles to Wet Areas
generally.
TL-02
Wall Tiles
05-400
TILES EXPO ARCHITECTURAL
Ceramic Tile
Type: Vision - GEN - C1 (matt white)
Colour:
Size: 600 x 300
Wall tiles generally - all
bathrooms.
TL-03
Wall Tiles
05-400
Feature Wall tiles to family
AGROB BUCHTAL
change vilage
Type: Erthenware
Colour: Random Pattern, combination - 1505 Light Blue,
1506 Soft Blue, 1507 Accent Blue, 1508 Deep Blue
Size: 147x147
TL-04
Wall Tiles
05-400
AGROB BUCHTAL
Type: Erthenware
Colour: 1506 Soft Blue
Size: 147x147
Feature Wall tiles to family
change vilage
Included in TL-03
TL-05
Wall Tiles
05-400
AGROB BUCHTAL
Type: Erthenware
Colour: 1507 Accent Blue
Size: 147x147
Feature Wall tiles to family
change vilage
Included in TL-03
TL-06
Wall Tiles
05-400
AGROB BUCHTAL
Type: Erthenware
Colour: 1508 Deep Blue
Size: 147x147
Feature Wall tiles to family
change vilage
Included in TL-03
TL-07
Skirting Tile
05-400
AGROB BUCHTAL
Range: Chroma II Series
Type: Cove Skirting - 31080
Type: External Mitre Pair - 37081
Type: Internal Mitre Pair - 37082
Colour: To match adjacent Wall Tile
AT-01
Acoustic Tile
Waterproof Membranes
Generally to Main Pool hall,
HERAGESIGN
Superfine, 600 x 1200 suspended ceiling system with VK- 25m Pool & WW Pool – wall
and ceiling
10 edge type on approved Knauf furring channel, Top
Cross Rail and suspension rods. All ceiling system
components are to be primed and painted in accordance
with the protectective coating specification after being
level set and tested. Use only heradesign supplied fixing
system.
Colours: TBA
WPM-01
Sheet membrane - subsurface
04-050
SIKA
Sikaproof A-12: TPO Sheet Preapplied Membrane. Roll
width 2.0m.
Fully and permanently bonded composite sheet
waterproofing
membrane system.
SikaProof Tape-150, self-adhesive, internal jointing
tapes based on Butyl-rubber, in 150 mm width.
SikaProof Extape-150, shelf-adhesive, external jointing
tapes based on Butyl-rubber, in 150 mm width.
Installed with Sika Greenstreak Waterbar - Centre Bulb
200mm for construction and/or expansion joints.
Full system installed by manufacturer instructed and
approved contractors in strict accordance with
manufacturer's current written specification.
WPM-03
Internal wet area
membrane - Walls &
Floors
04-050
BASF
PCI Lastogum X membrane.
The selected membrane shall be installed in strict
accordance with the manufacturers written instructions.
Install waterproof membrane reinforcement - PCI PECI
Tape at all corner junctions. Install in accordance with
AS3740.
Floors: This membrane shall be installed to all tiled
amenities areas within aquatic change rooms and
outside the aquatics areas.
Walls: This membrane shall be installed behind all tiled
walls across the site including in aquatic areas up to a
height of 2150mm. Note that this membrane is
compatible with Seccarol 2K.
Regarding the above membrane systems, the floors
slabs and walls must be prepared and primed to receive
the membrane material in strict accordance with the
manufacturer’s recommendations. The slab must have
cured for at least 28 days and must be sufficiency dry to
receive the membrane.
Typically inspections are required after each of the
following actions have been completed;
1.) after floors and walls have been prepared to accept
the membrane primer;
2.) after application of the membrane primer;
3.) after the membrane has been laid prior to covering
over.
WPM-04
Builder's film
04-050
200 micron black polythene sheet waterproof barrier.
WPM-05
Sealant
03-300
To concrete construction joints
SIKA
generally.
Sikaflex-Tank system.
High performance, chemical resistant polyurethane joint
sealant.
System installed in accordance with manufacturer's
current written specification.
WPM-06
Liquid membrane 04-050
Tiled floors to all aquatic
areas, except tiled
change rooms
SUPPLIER CONTACT
NUMBERS
COMPANY
Atkar
Andrews Group
Austim (Australian
Timber Products)
Austral Bricks
Autex
BASF
PCI Seccoral 2K membrane.
The selected membrane shall be installed in strict
accordance with the manufacturers written instructions.
The finished dry layer thickness of the membrane
material must be at least 2mm thick as required by the
manufacturer. Install waterproof membrane
reinforcement - PCI PECI Tape at all corner junctions at
all corner junctions.
The floors slabs and walls must be prepared and primed
to receive the membrane material in strict accordance
with the manufacturer’s recommendations. The slab
must have cured for at least 28 days and must be
sufficiency dry to receive the membrane.
Typically inspections are required after each of the
following actions have been completed;
1.) after floors and walls have been prepared to accept
the membrane primer;
2.) after application of the membrane primer;
3.) after the membrane has been laid prior to covering
over.
CONTACT
TELEPHONE
Travis Parker
Stuart Andrews
Alan Parker
03 9796 3333
0410 749 000
(08) 9409 6111/0457 999 525
Alana Maddock
George Georgiou
9303 4000/ 0404817879
0418 205 702
David Carroll
Justin Dennis
03 9876 2872 / 0419 332 306
0432 684 062
1800 677 052
sales@benchtopcity.com.au
sales@bentglass.com.au
russell@ceramicsolutions.com.au
Barrisol Australia
Bench Top City
Bent & Curved Glass Pty
Ltd
Boral
C/S Group
Capral
Ceramic Solutions
(Agrob Buctal tiles)
Chemind
Rob Capper
Russell Cook
1300 55 25 55
02 8543 4000
08 9302 8500
03 9545 5322 / 0419 113 777
Eral Dettrick
1800 33 44 44
Classic Ceramics
Sallie Boucher
0409 403 711
travis@atkar.com.au
stuart@the andrewsgroup.com.au
www.classicceramics.com.au
Bench Top City
Bolon
Ceramic Solutions
(Agrob Buctal tiles)
Classic Ceramics
CSP Architectural
(Alpolic)
CSR Bradford
CSR Gyprock
Dulux
DPJ Coating Systems
Elite Pool Cover
Eternit Asia panels
Everbright Roofing
Systems Pty Ltd
Fielders
Forbo
Justin Dennis
Stuart Andrews
Russell Cook
0432 684 062
0410749000
0419 113 777
www.benchtopcity.com.au
www.theandrewsgroup.com.au
Sallie Boucher
Kirk Wells
0409 403 711
0425 777 019
www.classicceramics.com.au
Daniel McKeown
Troy Stubbs
Bernard Schenk
Jan Bucknall
Steve Trower
1300 850 305
131 744
03 9263 5803
0418 384 262
0403 300 101
0418965116
(08) 9304 2132/0414 565459
Dean Lovett
Hilton Gaulbert
03 9300 7700
0148 617 961 / 1800 224 471
Gunnersen
GWA Group
(Caroma/Dorma
Supplier)
Hafele
Hufcor (Kyissa)
Hufcor (Operable Wall)
Interface
Johnson Tiles
Keystone Acoustics
Kingspan
Laminex
Locker Group
LouvreTec
MasterFibre
Mei Picchi
Monotek (flooring
systems)
Nellakir (Aust) Pty Ltd
Polyflor
Polysoft Pty Ltd
RBA Group (bathroom
Products)
Regupol
Resene Paint
Reynaers Aluminium
Southern Cross
Spectrum
SPS – Specialty
Plumbing Supplies
Stone Outdoors
Tiles Expo
Viridian
Wattyl
X Position
Woven Image
Biowood Australia
Ben Holod
Melissa Fredericks
03 9647 9911/ 0418336553
0409 763 591
www.equitone.com
http://www.everbrightroofing.com.au
mfredericks@gwagroup.com.au
Troy Stubb
03 9212 2000
03 9338 7400
03 9330 3733
03 9214 0713
www.interface.com
03 9720 4041
02 9604 8813
0420 414 844
mark.playdon@kingspan.com
13 21 36
1800 635 947 / 03 8791 1000
03 9770 4184
07 3376 7288
03 99004222
http://www.meipicchi.com
1800 062 301/ 0418384262
Geoff Toye
Adrian Conrick
Richard Lao
03 9355 7426
0404 817 283
(02) 9620 7231
Tony Merakis or Helen Osman
Simon Griffiths
Sandy Elliott
1300 788 778
02 46240050/ 0420 752 479
07 5512 6611
02 9666 0555
03 9561 9911
1300 786 585
Tyron
Samantha Edel
Mauro Faba
Catherine Lewocki
Mark Playdon
Peter Forrest
Jo
Con Kantis
Darren Morrison
Joseph Keenan
Melvin Fontanilla
(02) 9416 8031
1300303975
08 93288111
0423 820 884
(03) 9688 1287
03 9768 3996
9429 0142/ 0413 752 202
+61 429 77 3363
www.regupol.com.au
www.reynaers.com , info@reynaers.com
http://www.southerncrossceramics.com/
http://www.stoneoutdoors.com.au/
www.tilesexpo.com.au
http://x-position.com.au/
joseph.keenan@wovenimage.con
melvinf@biowoodaustralia.com.au
Product Selection
The naming of particular products in the Schedules indicates products of acceptable quality and design intent that may be approved, but does not mean exclusive preference for products.
Equivalent products may be used. Submit for approval details of proposed products before commencing.
The naming of proprietary products does not reduce or modify the Contractor’s responsibility to comply with the Contract Documents and warrant the work.
Before commencing, verify the correct selection of appropriate products for the substrates and conditions in accordance with the Product Information.
Revision History
Purpose
Issue:
Preliminary Tender
A
1 Tender
Date:
27.02.2015
06.03.2015
Project: 503085 - Leichhardt Park Aquatic Centre, Lilyfield
Client:
Leichhardt Park Aquatic Centre
Notes
This legend and schedule is to be read in conjunctions with the Specification and all other contract schedules.
All painted surfaces to be Dulux, unless otherwise stated.
Aluminium skirtings are to be clear anodised, unless otherwise stated.
All window and glazing framing systems to be Dulux powdercoat PPC-02, unless otherwise stated.
Issue: 2
Date: 07.04.2015
Refer to the Specification for detailed information of all finishes.
Spec
Ref
Code
TRS Description
BA-01
Plumbing Fixtures
Basin - Standard
Spec Description
BA-02
Basin - Standard
CAROMA INDUSTRIES
Carboni II Semi Recessed basin - 1TH
Ceramic White
Code: 865915W
GR-01
Grab Rail - Ambulent
VIRTU
Comfort 450mm x 450mm Grab Rail
Code: 84774545440
Installed according to AS1428
GR-02
Grab Rail - Acc
VIRTU
Virtu Comfort Grab Rail 960x600mm RHS/LHS
Code: 8479467440/8479465440
Installed according to AS1428.1
GR-03
Grab Rail - Acc
VIRTU
Virtu Comfort Grab Rail 300mm
Code: 84730040
Installed according to AS1428.1
GR-04
Grab Rail - Acc
VIRTU
Virtu Comfort Grab Rail 600mm
Code: 84760040
Installed according to AS1428.1
SH-01
Shower Head
Thornthwaite Technologies (Supplier)
RADA
Rada VR2 vandal resistant shower head
Chrome
8L/min
SH-02
Shower Head
DORF
Myriad Fixed Wall Shower
Code: 9154.043A
SH-03
Shower Head - Acc.
VIRTU
Plus Starsafe II Shower Ecojet Neu with Inverted T
Grab Rail RH/LH
Code: 782738/782739
SH-04
Shower Head Concourse
CAROMA
Indus Overhead Rain Shower
Code: 91051C2A
Comments
CAROMA INDUSTRIES
Carboni II Wall basin - 1TH
Ceramic White
Code: 865715W
Requires Caroma Right Angle Shower Arm
Code: 2464.04
SN-01
Sink - Kitchenette
CLARK
Monaco Single End Bowl LHB - 1TH
Code: 5113.1L
SN-02
Sink - Cleaners
CLARK
Cleaners Sink
Code: Y5100
WELS 3 star rated, 8.5L/min
WELS 3-Star (9 l/min)
Image
Rev
TP-01
Mixer Tap
WELS 6 star rated, 5L/min
Thornthwaite Technologies (Supplier)
PRESTO
Presto 2000 time flow tap 7.5sec (Hot and Cold pair)
Chrome
-Tepid taps to public change rooms and crèche. (one
centre hole)
- Tepid and cold supply to members areas - gym
amenities and football club change rooms (two taps on
the basin and no centre hole)
TP-02
Mixer Tap - Acc.
HANSA
Hansa Medica Prado Basin Mixer
Code: 014222760037
Installed according to AS1428
WELS 4-Star (7.5 l/min)
TP-03
Mixer Tap - Kitchen
CAROMA
Sarcoma Sink Mixer
Code: 98025C4A
WELS 4 star, 7.5L/min
TP-04
Shower Mixer
PRESTO
Presto 512 Valve - Timed Flow Control
Code: P31056
TP-05
Shower Mixer - Acc
HANSA
Hansa Medica Prado Shower Mixer
Code: 01470176
Installed according to AS1428
TP-06
Shower Mixer
DORF
Kip Bath/Shower Mixer
Code: 872882C
TP-07
Wall Tap - Cleaners
CAROMA
G Series Exposed Lever Wall Sink Set 115mm
Code: G52430CA
WELS 4 Star rated (7.5L/min)
UR-01
Urinal
1.8L cistern and WELS 3 star rated,
6/3L flush
WC-01
Toilet Suite - Public
CAROMA
Cube Urinal Invisi Series II Suite
nduct In ceiling / Inwall
Code: 771600W
Fitted with Invisi Series II rectangular single flush
custom buttons
Chrome rectangular single flush custom buttons
Code: 237022C
Cisterns to be located in ceiling space above urinals.
Supply and install 900 Long x 600 Wide Ceiling access
panel.
CAROMA INDUSTRIES
Caravelle Close Coupled Suite
Code: 989218
WC-02
Toilet Suite - Ambulent
compliant
CAROMA INDUSTRIES
Caravelle Easy Height Close Coupled Toilet Suite Caravelle Care Double Flap - Anthracite Grey
Code: 989370AG
WELS 4 star rated, 4.5/3L
Meets Ambulant AS1428.1
requirements
WC-03
Toilet Suite - Acc.
CAROMA INDUSTRIES
Care 400 Toilet Suite Suite with Backrest - Colani
Single Flap - Anthracite Grey
Code: 987900BAG
Installed according to AS1428.1
WELS 4 star rated Smartflush Suite
Meets AS1428.1 requirements
WC-06
Toilet Suite - Creche
CAROMA INDUSTRIES
Junior 2000 Connector BI S Trap Suite
Wall Faced
Code: 984251W
WELS 4 star rated, 4.5L/3L
Smartflush
ZIP-01
Zip HydroTap
ZIP
Zip HydroTap
Zip Model: Zip HydroTap G4 BC 160/175
Order Code: HT1704
ZIP-02
Zip Autoboil
ZIP
Zip Autoboil wall mounted unit
Zip Model: Autoboil AB025FX
Order Code: 12054
2
WELS 4 star rated, 4.5/3L Smartflush
Suite
BC-01
Sanitary Fittings
Baby Change
RBA
Koala Baby Change Table
Vertical Wall Mounted Stainless Steel Finish
Code: KB111-SSWM
FS-01
Folding Shower Seat Acc
BRADLEY
Surface Mounted Folding Seat
Model 9558-40
Stainless Steel tubing with White laminate seat bonded
to a phenolic core
HD-01
Hand dryer - Standard
JETDRYER
Jetdryer
Casing: Polycarbonate ABS
Colour finish: Grace White
Filtration: Antibacterial coated PHMG Filter
Installed to product recommendations.
HD-02
Hand dryer - Acc.
RBA
TrimLine Surfaced Mount Accessible Compliant Hand
Dryer
Code: B7128E
Installed to product recommendations.
Installed according to AS1428
MR-01
Wall mirror
Refer to Wet Area elevations & shop
VIRIDIAN DÉCOR MIRROR SAFE
changing room layouts
Frameless
Point fixed through wall lining
Refer to internal elevations for dimensions and setouts
Colour: 4mm clear
PT-01
Paper Towel Dispenser
BRADLEY
Towel Dispenser
Stainless Steel Satin Finish
Tumbler lock
Model 2442 - Recessed
RH-02
Robe Hook
CAROMA
Cosmo Metal Robe Hook
Code:309128C
RH-03
Robe Hook - Acc
VIRTU
Circut Robe Hook with Backplate
Code: 0916C
SD-01
Soap Dispener
BRADLEY
Surface Mounted Liquid Soap Dispenser
Stainless Steel Satin Finish
Model 6562
SD-02
Soap Holder - Acc
BRADLEY
Surface Mounted Soap Dish
Type Regent R021
Surface Mounted
Polished Stainless Steel Finish
SD-03
Soap Holder
BRADLEY
Surface Mounted Soap Dish and Shelf
Type Regent R0941-21-12
Surface Mounted
Polished Stainless Steel Finish
SR-01
Shower Rail - Acc
BRADLEY
Corner Shower Curtain Rail - Standard Size 1200 x
1200 x 600 Ceiling Support
Stainless Steel Finish
Model 953-CNR including
Shower Curtain 1800H x 1200W
Model 9537
TH-01
Toilet Roll Holder Standard
BRADLEY
Jumbo Toilet Tissue Dispenser
Stainless Steel Satin Finish
Surface mounted
Model 5424
TH-02
Toilet Roll Holder - Acc.
BRADLEY
Toilet Tissue Dispenser
Satin Finish
Double roll toilet tissue dispenser.
Model 5234
Installed according to AS1428
PS-01
Toilet partition system
RS-01
Roller Shutters
Roller shutter
RS-02
Tilt Up Door
FLUSH PARTITIONS AUSTRALIA
Hardicolour
18mm Compressed Fibre Cement Sheeting
Colour: Clear two pack polyurethane finish with
compact laminate doors
Doors: 13mm compact laminate - Laminex
Colour: TBC
All support aluminium to be anodised finish including
H200mm legs dynabolted through floor. Partitions to
include all hardware eg coat hooks/ door bumpers,
indicator sets
Dimensions: refer to Architectural drawings.
Generally to all concourse
public/change toilets and showers
Generally to Pool Hall areas
AUSTRAL MONSOON
Austral Monsoon or acceptable equivalent Panorama
E85 aluminium roller shutter.
Slats: Fully solid
600x600 proprietary access panels under motors
typical.
Emergency chain rolled up in ceiling space adjacent to
access panel
Battery backup and connection to FIP for auto open
upon fire alarm activation. Include push to exit button
Finish: Powder coat finish. Colour to be confirmed by
the Superintendent. DFT 100 Microns.
Operation: Motorised (3-Phase). Motor to be fully boxed
in with custom aluminium sealed removable cover.
Battery backup and connection to FIP for auto open
upon fire alarm activation. Include push to exit button.
Include Logic control for swipe interface where
indicated on the door schedule. Allow for keyswitch on
the external side of the door in addition to swipe card
facility.
Battery backup and connection to FIP for auto open
upon fire alarm activation. Include push to exit button
Refer to Door Schedule for sizes
MONARCH DOORS
Renlita Series 3000 two-leaf floataway counterbalanced
door.
Twin leaf counterbalanced aluminium framed panels
with glass infill and hinged horizontally.
Aluminium framed fully glazed door. Viridian VLAM
toughened 10mm thick Grade A safety Glass in
accordance with AS1288. Door shall be suitably braced
to withstand wind loadings in the closed position and
provide minimum deflection in the open and closed
positions.
High alloy grade 904L austenitic stainless steel cables
chains all other internal componentry subject to tension.
Finish: PCC finish to 100 microns
G. Size varies. Refer to drawings and door schedule.
Measure and confirmed on Site prior to manufacture.
H. Counterweights shall be enclosed and protected
using 3mm thick powdercoated aluminium covers and
shall be fixed to the guide channel and wall.
I. Motorised operation. Refer to Electrical Services
documents. Motor 415V-3 Phase Door Drive,
240V reversing contactor and key switch operation.
Pool Equipment
Electrical Applicances Kitchen
REF-02
Refrigerator Undercounter
THERMOMASTER
S/S Bar/ Undercounter Fridge
Model: HR200 s/s
Group 1
Konica Minolta
Colour laser printer, scanner and copier
Code: bizhub C554e
Group 3
CABLE GATE (Matilda Products)
Automated chain gate barrier
Card reader Access Control System
FFC & CoC Staff Secure Car Parks.
Refer Architectural drawings
Interloc
Premium Specification - Wave Locker Doors with
bench seat.
Locker Type Code: G IL High Plinth
Finish to be Nuvex (JTM-01). 316 SS frames for
lockers and seats.
Size: W300mm x D500mm x H1450mm on a 450mm
plinth.
Finish to be Nuvex.
Colour: TBA. Refer to Architectural drawings.
RFID Reader for cards and wrist bands with LINKS
control system. One per locker.
Allow power and data.
Refer Plans. Locations to be
confirmed on site.
* All lockers shall be hard wired to the
LINKS Members electronic system
utilising the Gantner or equivalent
control system. Coordinate with the
Electrical Services documents. RFID
type operation and locks unless noted
otherwise inclusive of associated
software and all required integration
into LINKS system
*All lockers shall be connected to a
proprietary UPS battery backup
system.
Electrical Applicances Audio Visual
PR-01
Printer/ copier/ scanner
CG-01
Landscape
Cable Gate
LK-01
Equipment Other /
Items
Lockers
Product Selection
The naming of particular products in the Schedules indicates products of acceptable quality and design intent that may be approved, but does not mean exclusive preference for products.
Equivalent products may be used. Submit for approval details of proposed products before commencing.
The naming of proprietary products does not reduce or modify the Contractor’s responsibility to comply with the Contract Documents and warrant the work.
Before commencing, verify the correct selection of appropriate products for the substrates and conditions in accordance with the Product Information.
Revision History
Purpose
Issue:
PRELIMINARY TENDER
A
1
TENDER
Date:
27.02.2015
13.03.2015
Project:
Client:
503085 - Leichhardt Park Aquatic Centre, Lilyfield
Leichhardt Park Aquatic Centre
Notes
This legend and schedule is to be read in conjunctions with the Specification and all other contract schedules.
All painted surfaces to be Dulux, unless otherwise stated.
Aluminium skirtings are to be powdercoated, unless otherwise stated.
All window and glazing framing systems to be Dulux powdercoat PPC-*, unless otherwise stated.
Issue: 2
Date:07.04.2015
Refer to the Specification for detailed information of all finishes.
Code
TRS Description
Spec
Ref
BL-01
Access & Safety
Equiptment
Balustrade
05-800
Galvanised steel balustrade and nominal Ø40mm
handrail mounted to floor / stair tread. With galvanised
steel kickplate 150Hx5THK offset 200mm AFFL.
Paint finish - PCC-09.
Ø15mm galvanised steel rod infill balusters at max
125mm cts.
Refer Architectural documentation for extent and details.
Must comply with BCA and AS1428
HR-01
Hand rail
05-800
Nominal Ø40mm handrail mounted to wall - fixings to
match handrail finish.
Stainless steel 316, linished finish.
Refer Architectural documentation for extent and details.
Must comply with BCA and AS1428
HR-02
Hand rail
05-800
Nominal Ø40mm handrail mounted to floor - staunchions
and fixings to match handrail finish.
Stainless steel 316, linished finish.
Refer Architectural documentation for extent and details.
Must comply with BCA and AS1428
Spec Description
Location
Comments
Rev
Access Panel
AP-01
Ceiling access panel plasterboard
05-050
Ceiling access panel to suit suspended plasterboard
ceiling. Sizes as nominated on the drawings, 600 x
600mm typical. Flush finish. Finish to match ceiling
finish. No perimeter trims. Refer to the drawings for
locations.
Refer to RCP for extent.
Coordinate with Mechanical &
Electrical drawings.
Allow access panels for under
Roller Door motors
AP-02
Ceiling access panel Compresses Fibre
Cement Sheet
05-050
Ceiling access panel to suit CFC sheet ceiling. Sizes as
nominated on the drawings, 600 x 600mm typical. Flush
finish. Finish to match ceiling finish. No perimeter trims.
Refer to the drawings for locations.
Refer to RCP for extent.
Coordinate with Mechanical &
Electrical drawings.
Allow access panels for under
Roller Door motors
EM-01
Carpet
Entrance Matting
05-550
CS CONSTRUCTION GROUP
Type: Recessed PediTred G4
Colour: Monotuft 'Graphite'
Finish: Clear Anodised
CP-01
Carpet tiles
05-550
INTERFACE Microtuft Patterned Level Loop Pile
Style : Flatweave
Style Code : Fusion 1543
Code: 1543-001-000
Colour: Hybrid
Backing: GlasBac
Size: 50cm x 50cm x 4.5 mm +/- .5mm
Installation method: Quarter turn
LTS Office
CE-01
Ceilings
Ceiling Type - Fixed
Plasterboard PB-01
05-050
BORAL PLASTERBOARD
Thickness: 13mm with 600mm min. fixings
Flush jointed tape joints
Paint Finish.
Rondo P50 joints at edges.
Refer to RCP for extent and
location.
CE-02
Ceiling Type - Fixed
Plasterboard PB-03
05-050
BORAL
Fibre Cement Sheeting
Flush jointed tape joints
Paint Finish.
Rondo P50 joints at edges.
Refer to RCP for extent and
location.
CE-03
Ceiling Type - Fibre
Cement - FC-02
05-050
BORAL
Fibre Cement Sheeting
Thickness: 9mm with 600mm min. fixings
Express jointed
Paint Finish.
Feature Ceiling in Change
rooms and pool hall.
CE-04
Ceiling Type - Acoustic
panel
05-050
One layer Heradesign Superfine 25mm 1200x600 on
Knauf furring channels. Instalation to suit tecnical
processing guidlines.
Colour TBC.
Cornice
CN-01
Cornice - Shadow-line
05-050
RONDO BUILDING SERVICES
P50 10mm shadowline stopping angle. Set flush.
CN-02
Cornice - Square Set
05-050
RONDO BUILDING SERVICES
Square Set
Concrete finishes
2
CON-01
Worked concrete finish - 03-300
power
Power floated concrete finish. Suitable for vinyl and
carpet finishes by other trades. Flatness of 3mm over
3metres.
CON-02
Worked concrete finish - 03-300
hand
Worked concrete finish - 03-300
broom
Hand trowelled concrete finish. Suitable for tiled
surfaces.
Broom finish concrete to external pavement/concourses.
CON-04
Concrete stair finish
03-300
SC-01
Concrete sealer
05-600
80mm Granolithic concrete screed forming stair treads,
risers and landings.
SIKA
Sikafloor Curejard 24.
Dust-proofer / sealer / hardener: a one part, clear liquid
based on sodium silicate to cure, harden and seal fresh
or hardened concrete.
SC-02
Polysoft
05-500
VERSATEX Standard non-pourous over approved hard
surface and 'polysoft primers'. with 100mm integral
monotek coving to wall and floor junctions.
Colour: Ash 50%, Granite 50%, Granite tinting.
Supply and Install by approved installer with consultation
from Polysoft prior to install.
Methodolgy: In accordance with "Polysoft Versatex
Specifications"
SCR-01
Screed - Pool
Concourses and pool
amenities with applied
Polysoft finish
05-300
Light nylon broom finish. Surface must be clean and free
of contaminants such as grease, dirt and existing
unsound coatings. This is to be checked and cleaned by
contractor.Concrete surface must be acid etched shot
blast or diamond grind to remove any contaminants and
achieve a finish to enable a mechanical bond between
substrate and primer. If a curing agent has been used
the surface must be checked for compatibility (test for
adhesion) or removed prior to installation. In an open
area cut a small groove in the concrete along the
finishing line to anchor the broadcast at that point.
SCR-02
Screed - General wet
areas
05-300
General screed (Bonded)
Generally to tiled areas
Supply and install tiling screed to floors in wet areas and
where indicated on the drawings. The screed mix shall
be plant prepared granolithic concrete screed to 32Mpa
minimum strength. Screeds shall be placed over
structural concrete where specified. The granolithic
screed shall NOT be less than 35mm
Spread the screed mix to specified falls and cross falls,
compact and float to the required tolerance and as
required for the specified surface finish. The surface
shall be prepared and a coat of commercially
manufactured and compatible bonding agent shall be
applied prior to the granolithic screed being placed.
Install waterproof membrane to top of screed to falls.
Membrane shall be PCI Seccoral 2K” flexible acrylic
based liquid. To be applied to the base and sides of all
wet areas shown and/or specified and extended full
height up all adjacent walls, and to be applied to the full
extent of ALL tiled wall faces, all in accordance with the
manufacturer's instructions.
CON-03
Generally to Pool hall LTS
reception.
Builder must supply warranty of
2 years against failure and
cover supply and installation of
the material.
2
EJ-02
Expansion /
Expansion Joint Cover
03-300
LATHAM
Floor expansion joint cover - Stainless steel.
CS-25 Ultimate Series.
Including VWS Water Gutter.
Generally to all expansion
joints to structural slabs where
a surface lining is applied.
Refer to Structural Engineers
Drawings for location(s).
EJ-04
Expansion Joint Cover
03-300
LATHAM
Floor-to-wall expansion joint cover - Stainless steel.
SAS-25 (SSSM 104) Ultimate Series.
Including BFG Water Gutter.
Generally to all expansion
joints to slabs/walls where a
topping slab is applied. Refer to
Structural Engineers Drawings
for location(s).
TM-01
External Cladding
Biowood Wood - Plastic
composite
04-203
BIOWOOD
WP.01.150.18 Shiplap cladding to be laid horizontally
Fixing method: Liquid nails and screw fix to substrate in
accordance with installation guide
Coating: 2 coats intergrain 'Grey' in accordance with
technical specification
Panel joints:
Thickness:18mm
Colour: Weather Wood
Refer to elevations for extent
and panel sizes.
The Manufacturer's Warranty
shall be for 15 years.
The installation is to be carried
out by the manufacturer
representative's approved
installers only.
04-203
BIOWOOD
S4SO05050 Side 4 Side Outdoor 50x50 battens with
internal aluminium stiffening rods
Fixing method: Liquid nails and screw fix to substrate in
accordance with installation guide
Coating: 2 coats bioseal / intergrain
Panel joints:
Thickness:50mm
Colour: Weather Wood
Refer to elevations for extent
External concourse pergola, and window awnings 2
and locations
where shown.
The Manufacturer's Warranty
shall be for 15 years.
The installation is to be carried
out by the manufacturer
representative's approved
installers only.
TM-02
Biowood Wood - Plastic
composite
Glass & Frame Types
GL-01
Clear glass - Double
glazed
04-500
VIRIDIAN
PerformaTech Clear (#2) 6 toughened glass + 12mm
argon + 6mm VFloat toughened Grade A Safety glass.
U-value 1.4
SHGC = 0.38
Glazier to undertake their own assessment of size,
thickness and for thermal breakage / fracture (heat
treatment). All glazing to AS1288-2006 and BCA.
Generally to pool hall and
family change area
GLD-01
Decal film on glazing
04-500
Glazing Decals to AS1288.
Continuous, repeated opaque symbol / logo.
Min. 100mm high band.
To all full width of glazing.
Logo to be provided by Principal.
Refer to Window schedule for
extent.
GF-01
Glazed Framing System 04-500
REYNAERS
Reynaers CW-50 Single Glazed
150mm x 50mm front glazed suite.
Finish: Powdercoat
Internal:
Dulux – PN2E1 “Vivid White”
External:
Dulux PG1F7 – “Western Myall”
Typical glazing frame to
external and internal facade.
GS-01
Colourback Glass
Colourback Glass. All edges to be polished.
Colour to match PT-0*
kitchen benches generally
06-202
Insulation
IN-01
Thermal insulation (roof - 04-203
less than 5 degree pitch)
CSR BRADFORD
CSR Bradford Anticon 140 Roof Blanket, Rm3.3, 140mm
thick, 13.5kg/m3 Glasswool bonded to medium duty
silver reflective foil.
Installation: in combination with CSR Bradford Ashgrid
Roof Spacer 120mm high (20mm sag in safety wire
allows blanket to recover to full thermal performance of
140mm).
R-Total roof solution of Rt3.7 Winter and Rt4.0 Summer.
IN-02
Thermal insulation (roof - 04-203
box gutters)
CSR BRADFORD
CSR Bradford Anticon 55 Roof Blanket, Rm1.3, 60mm
thick, 11.0kg/m3 Glasswool bonded to medium duty
silver reflective foil together with CSR Bradford Dow
Thermax-Light Duty Rm2.9, 63.5mm thick PIR Board
with silver facing.
Installation: Anticon blanket to be laid over gutter support
strapping with foil facing down. Thermax Board cut to
size and installed belowand to sides of gutter prior to
installation of box gutter.
R-Total roof solution of Rt3.7 Winter and Rt4.0 Summer.
IN-03
Thermal insulation
(external walls)
CSR BRADFORD
CSR Bradford Gold Wall Batts, Rm2.5, 90mm thick, High
Performance, 22.0kg/m3 Glasswool together with CSR
Bradford Enviroseal Proctor CW (Commercial Wall)
Breather sarking, non-reflective wall wrap.
Installation: Insulation installed between metal studs and
continued up to underside of roof insulation so to fully
encapsulate thermal envelope. Wall wrap to be fixed to
outside of stud frame, lap 150mm and tape all joints;
repair any damage and tape around all penetrations.
R-Total external wall solution of Rt2.8 Winter.
IN-04
Thermal/acoustic
05-100
insulation (internal walls)
CSR Bradford
Partition Wall Batts 165, Rm3.5, 165mm thick,
11.0kg/m3 Glasswool batts.
Batts installed between studs to walls that require a
reduction in noise transfer.
Internal 150mm steel stud walls
- Acoustic solutions to comply
with acoustic engineer’s report
IN-05
Ceilings - general
05-050
CSR Bradford
Building Blanket 80, Rm1.8, 80mm thick, 11kg/m3
Glasswool at 1200wide. Blanket rolled out over
suspended ceiling system prior to installation of sheet
plasterboard or modular ceiling tiles.
Refer Architectural documents.
05-100
Joinery Finishes
JC-02
Joinery - Component
06-202
HAFELE
Stainless Steel Handle
140mm wide x 35mm high
Cat No: 109.32.902
Colour: Anodised Aluminium
LTS Office area joinery
JCP-01
Joinery - Compact
Laminate
06-202
LAMINEX
Colour: Laminex Polar White Flint Finish
LTS Reception
JL-01
Joinery - Laminate
06-202
LAMINEX
Colour: Laminex White Natural finish. 200
LTS Office area joinery
JL-02
Joinery - Laminate
06-202
LAMINEX
Colour: Laminex Steel Blue, Natural finish.
LTS Office area under bench
JL-03
Joinery - Laminate
06-202
BENCH TOP CITY
Range: Admira
Colour: Azure Linen
(2440 x 1220)
Joinery - Part Reception
JO-01
Opal Acrylic
06-202
Opal acrylic diffuser to face of concealed LED lighting
2
JSK-01
Skirting
06-202
JTM-01
Joinery – Bench Seating 06-202
100mm high natural anodized aluminium flat.
Skirting to all joinery as noted
on drawings
NUVEX
19mm Nuvex Slotted Bench Seating with 316 stainless
steel frame and mounting brackets. Linear slots.
Install new top max. 440mm AFFL to suit locker plinth
450mm AFFL.
Colour: Pure White.
Frame (where floor mounted): 38x38 SHS 316 polished
Stainless Steel Frame Frame (where wall mounted):
440x12mm custom satin stainless wall brackets with
38x38 SHS 316 Satin Stainless Steel stiffeners/framing
as required. Refer to Architectural drawings.
Foot: Castors & Industrial Products AF 31/40/M10/60
40xM10 500Kg 'A-Justa-Foot' with custom fabricated.
Typical Bench seating in
changerooms either floor
mounted or wall mounted.
Refer architectural drawings.
COLT
Colt louvre system: Ventilation and Rain Defence
Louvre.
Series: ERD.
Maximum blade span: max. 1250mm.
CAPRAL
Capral 89mm Louvre
Finish: Powdercoat PPC-12 (to match glazing frames).
Fixed aluminium louvre to be fitted to Capral 419 Series
frame.
REYNAERS
Finish: Powdercoat PPC** (to match glazing frames).
Refer to elevations and louvre
schedule for location. Generally
to upper level facade.
Louvres
04-500
LV-01
Louvres - Plant Screen
LV-02
Fixed Aluminium Louvres 04-500
LV-03
Operable Glazed
Louvres
04-500
Refer to Architectural
Elevations and to Architectural
and Mechanical Louvre
Schedule for locations.
Refer to Architectural
Elevations and to Architectural
and Mechanical Louvre
Schedule for locations.
Masonry
BLK-01
Face blockwork
03-650
BORAL
150 Series (140mm) Standard Natural Block - concrete
blockwork.
Colour: Charcoal
BLK-02
Fire rated blockwork
03-650
Refer to wall types for extent.
BORAL
190mm block work to achieve a 120/120/120 Fire Rating
(Boral Scoria Blend or similar).
Reinforced and core filled where nominated by the
structural engineer.
BLK-03
Polished faced blockwork 03-650
Refer to wall types for extent.
BORAL
Series 150 Designer Block (140mm thickness)
Finish: Random pattern, even spread of smooth, Shot
Blast, Honed
Structural: Core fill blockwork with N32 concrete. N20
bar reinforcement tied into the slab / strip footing. Refer
also to Engineers details.
Colour: Charcoal
Mortar: Allow for coloured mortar. Colour TBC. Mortar
mix shall be cement, lime and sand as specified, with
proportions to AS 3700 and AS 1316.
Sealing: Seal blockwork with Duramax MAXISEAL
premium clear sealer from DURAM INDUSTRIES
BLK-04
Polished faced blockwork 03-650
Refer to wall types for extent.
BORAL
Series 150 Designer Block (140mm thickness)
Finish: Random pattern, even spread of smooth, Shot
Blast, Honed
Structural: Core fill blockwork with N32 concrete. N20
bar reinforcement tied into the slab / strip footing. Refer
also to Engineers details.
Colour: Pearl Grey
Mortar: Allow for coloured mortar. Colour Pearl Grey
Mortar mix shall be cement, lime and sand as specified,
with proportions to AS 3700 and AS 1316.
Sealing: Seal blockwork with Duramax MAXISEAL
premium clear sealer from DURAM INDUSTRIES
BLK-05
Face blockwork
03-650
BORAL
200 Series (190mm) Standard Natural Block - concrete
blockwork.
Colour: Charcoal
Paint / Clear / Renders
Finishes
PAA-**
Acrylic Paint - Blockwork 05-600
DULUX
DULUX AcraTex 955 AcraShield
Specification No: AUSA2957
(new blockwork - internal & external).
Refer to wall types for extent.
Refer to wall types for extent.
PAB-**
Acrylic Paint - Concrete
05-600
DULUX
DULUX AcraTex 955 AcraShield Low Gloss - 501/2
AcraPrime
Specification No: AUSA5627
(new concrete colour finish - internal & external)
PAC-**
Acrylic Paint - Interior
ceilings
05-600
DULUX Wash and Wear 101.
Flat Acrylic. DULUX spec AUSD0001.
(plasterboard ceilings - internal & dry)
PAD-**
Acrylic Paint - Interior
walls
05-600
DULUX Wash and Wear 101.
Advanced Low Sheen Acrylic. Plasterboard - DULUX
spec AUSD0002.
(plasterboard walls - internal & dry)
Refer to Finishes schedule and
internal elevations
PAE-**
Acrylic Paint - External
FC
05-600
DULUX
AcraTex 955 AcraShield
Specification No: AUSA0900
(cfc / villaboard ceiling & walls - external)
Refer to Finishes schedule and
internal elevations
PCA-01
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule A
*Preparation and painting of all new exposed mild steel
sections.
PCB-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule B
*Preparation and painting of all new hidden mild steel
sections.
PCC-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule C
*Preparation and painting of all new internal concrete
floor surfaces
PCD-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule D
*Preparation and painting of all new galvanized steel, on
site, in-situ
PCE-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule E
*Preparation and painting of all new steel sections, on
site, in-situ
2
PCF-**
Protective Coating
05-600
DULUX.
Dulux Protective Coating: Specification No: V14/292R2
Schedule F
*Preparation and painting of all new steel sections, on
site, in-situ (Knauf)
2
PES-**
Paint - Enamel Semi
gloss
05-600
DULUX
Aquanamel Semi Gloss.
PPC-**
Powdercoat
05-600
DULUX Powdercoating.
For Aluminium: Dulux Duratec X15. Refer DULUX
Specification: AUSP5617.
For Galvanized Steel: Dulux Duralloy FG. Refer DULUX
Specification: AU_DP01827.
PTM-**
Timber finish - natural
stain - clear, matt to low
sheen finish
05-600
DULUX. Intergrain Natural Stain. Refer to DULUX spec
AUSW3901. (External timber)
PT-01
Wall Paint finish
Generally
05-600
Colour: Dulux Wash and Wear Low Sheen Water Based Walls generally
Acrylic
Colour: Natural White PN1E1
PT-02
Ceiling Paint fnish
generally
05-600
Dulux Professional Tintable Ceiling Flat
Colour: Natural White PN1E1
Ceilings Generally
PT-03
Ceilings and Walls - Wet 05-600
areas
Dulux Mouldshield "Wash and Wear Bathroom Ceiling
Flat" Water Based Acrylic
Colour: Natural White PH1E1
Bathroom and Wet area
ceilings and part walls
PT-05
Trims Paint Finish 05-600
Skirtings/ Internal Doors/
Door Frames.
Dulux "Wash and Wear" Semi Gloss Water Based
Acrylic
Colour:
PT-06
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Lagoona Teal P30H3
Feature Ceiling and Walls
PT-07
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Santorini P33H3
Feature Ceiling and Walls
PT-08
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Rollercoaster P35H6
Feature Ceiling and Walls
PT-09
Feature Ceiling and
Walls
05-600
Dulux "Wash and Wear" Water Based Acrylic
Colour: Shimmer P35H1
Feature Ceiling and Walls
Plasterboard/ Linings
2
PB-01
Plasterboard
05-100
CSR GYPROCK
13mm plasterboard with recessed edges. Flush jointed.
Paint finish.
Refer to Wall / Ceiling types
PB-02
Plasterboard Fireboard
05-100
CSR GYPROCK
16mm Fyrcheck plasterboard
Paint Finish
Refer to Wall / Ceiling types
PB-03
Plasterboard Multiboard
05-100
CSR GYPROCK MULTIBOARD
13mm multiboard plasterboardwith recessed edges.
Flush jointed. Paint finish.
Refer to Wall / Ceiling types
FC-01
Fibre Cement
05-100
Refer to Wall / Ceiling types
JAMES HARDIE VILLABOARD
9mm Flush jointed with recessed edges.
Paint finish surface. Allow for 12 Dulux Colours (PAE-**)
Use perforated paper reinforcing tape, embedded in
James Hardie base and top coat jointing system.
Support eaves as required given the wind classification
for the site.
FC-02
Cladding Compressed
Sheet - with expressed
joints
05-100
JAMES HARDIE
Proprietary James Hardie 9mm Versalux system, but on
proprietary ExoTec® Gasket Snap Strips with bubble
gaskets.
Provide 10 mm expressed joints refer to elevations for
details
screw heads covered by epoxy and James Hardie Base
Coat over
Apply a continuous 6mm diameter bead of polyurethane
sealant to the backing strips.
Installation in accordance with James Hardie Exctec
installation recommendations / requirements.
Paint finish surface (PAE-**) Colours to be confirmed
FC-03
Fibre Cement - External
Soffits
05-050
Refer to RCP for locations
JAMES HARDIE VILLABOARD
6mm Flush jointed with recessed edges.
Paint finish surface. Allow for 12 Dulux Colours (PAE-**)
Use perforated paper reinforcing tape, embedded in
James Hardie base and top coat jointing system.
Support eaves as required given the wind classification
for the site.
04-204
EVERBRIGHT
Everbright E610 polycarbonate cladding system installed
vertically.
74mm thick wall panels
Colour:Clear
All trims, flashings, etc. to be powdercoated - PPCDulux PG1F7 – “Western Myall”
Installed with proprietary seals, fixings, trims, etc to
manufacturer's current written specification, by trained,
licensed and approved installers.
Generally to Pool Hall walls
and feature ceiling
Refer to Elevations for paint set
out.
Refer to ACCEL Technical
Supplement “Lining an Indoor
Swimming Pool Area” – edition
36 2012
Polycarbonate
PLC-01
Polycarbonate wall
system
Resilient Materials
FL-01
Flashings
04-203
Refer to Roof plans for
COLORBOND
locations
Folded 0.8mm flashings formed from sheet material
equal to type MT-01 metal roof cladding. Allow for up to
8 folds in flashing.
Finish: *******
*All flashings to be weather sealed at laps and along the
full length by an unbroken bead of 6 x 4mm thick butyl
rubber sealant tape
*(Kingspan reference S-EXT).
*All internal flashings to be made from 0.55mm thick
steel substrate, to the same specification as the liner
sheet of the panel.
*All flashings to have butt straps and sealed with two
unbroken runs of 6 x 4mm thick butyl rubber sealant
tape.
*End laps to be air sealed with gun grade sealant.
*All primary fasteners must be the high threaded type,
manufactured from Austenitic Grade 304 stainless steel
fasteners and fitted with a 19mm diameter bonded
stainless steel washer. All Fasteners MUST be fixed
through the Crown of the panel only. To comply with
local wind requirements, it may be necessary to provide
additional fixings in areas of high local suction.
*Side laps and external flashings to be stitched at
450mm centres (maximum) with carbon steel stitching
screws, complete with bonded 14mm diameter carbon
steel washers.
*Internal flashings to be stitched at 450mm centres with
Austenitic Grade 304 stainless steel fasteners or rivets
and fitted with a 14mm diameter bonded stainless steel
washer.
FL-02
Roofing - penetration
flashings
04-203
DEKTITE
EDPM proprietary flashing
FL-03
Parapet / fascia capping 04-203
Folded parapet capping formed from sheet material
equal to type MT-** metal roof cladding.
FL-04
Custom sharknose
fascia capping
Folded fascia capping formed from sheet material equal
to type MT-01 metal roof cladding. Allow for min. 7 folds
04-203
2
FW-01
Floor Waste
06-203
M A GRIFFITHS
MAG-MIFAB BS1100-R. Product code: Ass. No. 70100
• e: 100mm diameter grade 316 stainless steel.
• Strainer secured to body section with anti-vandal
stainless steel counter sunk screws.
FW-02
Trench Drain
06-203
ACO POLYCRETE (or acceptable equivalent)
Grade 316 stainless steel trench drain (custom
fabricated to all showers with flanges to all sides for
membrane adhesion. Submit shop drawings.
• System trough with safety edge and tile flange.
• Base of drain to have 1:100 fall.
• Outlets are to be located a minimum of 200mm from
the cubical walls to allow cleaning access.
Number of outlets as per the Hydraulic Engineer's
drawings.
• Grade 316 stainless steel waste baskets.
• Heelguard™ grade 316 stainless steel class A antislip
grates.
• Finish: Pickle passivated.
BG-01
Box gutter - Proprietry
04-203
Refer to Roof Plan for location
KINGSPAN
Proprietary Kingspan membrane lined insulated Box
gutter. In maximum lengths and welded joints.
External weather sheet: substrate to be minimum 0.6mm
pre-galvanized coated steel to AS1397 with IKO 0.6mm
or IKO 1.2mm thick PVC membrane.
Insulation Core: consist of 60 or 120mm thick, closed
cell, CFC and HCFC Free FM certified polyisocyanurate
(PIR) insulation. Insulation core bonded to the external
and internal sheets during manufacture.
Internal Liner sheet: Substrate to be 0.5mm to 0.7mm
thick steel S220GD+ZA hot-dip zinc/aluminium coated
steel to AS1397. Coating to be Kingspan Aquasafe
standard bright white.
BG-02
Box gutter - Generally
04-203
Refer to Roof Plan for location
COLORBOND
Colour: **
Box gutters to be made from 0.80mm folded colorbond
steel sheet to the sizes nominated on the hydraulic
engineers drawings.
Allow for associated Lysaght Spandek gutter board,
gutter brackets, outlets, expansion joints, etc.
Sumps to be made from the same material as above to
the sizes nominated on the hydraulic drawings.
Where Spandek gutter board and brackets are exposed
allow to fully paint with system nominated within the
specification for painting over galvanised surfaces.
DP-01
Roof Downpipes
04-203
COLOURBOND DOWNPIPES
Material: refer Hydraulic Engineer.
Shape: round.
Size: 150mm typical – refer Hydraulic Engineer.
Colour: ***
EG-01
Custom Sharknose
Profile Eaves gutter
04-203
Custom sharknose profile eaves gutter, formed from
sheet material equal to type MT-01metal roof cladding.
Allow for min 7 folds
EG-02
Eaves gutter
04-203
100mm quad eaves gutter - colour to match adjacent
wall cladding
MT-01
Metal roof cladding Refer roof plans
04-203
Refer to Roof Plan for location
KINGSPAN
KS1000 RW/FM Trapezoidal Roof System.
With liner substrate to be 0.5mm thick steel S220GD+ZA
hot-dip zinc/aluminium coated steel to BS
EN10214:1992. Internal coating to be Kingspan
Aquasafe standard bright white. High Humidity internal
and Standard (non-corrosive) external environments.
Thickness: 100mm core thickness; 135mm overall
thickness.
Colour: Gull Grey (top side), Off White (underside).
Sealant: Bostik 5250 preformed mastic tapes.
Select system to suit marine environment.
Grade 304 stainless steel fixings.
MT-02
Metal roof cladding Refer roof plans
04-203
LYSAGHT
Colorbond 0.48 BMT.
Blue Scope Lysaght 'Klip Lok'.
Colour:**
Refer to Roof Plan for location
MT-03
Metal Internal parapet
cladding
04-203
LYSAGHT
Colorbond 0.48 BMT.
Blue Scope Lysaght 'Spandek.
Colour: **
Generally to the roof side of all
parapets.
OF-02
Roof - Overflow outlets
04-203
Horizontal overflow through facade.
Shape: Rectangular - typical nom. 300mm wide x 80mm
high.
Size: refer Hydraulic Engineer for confirmation of size.
To match adjecent wall cladding.
SK-01
Aluminium Skirting
05-100
Aluminium clear anodised
Height: 100mm
2
Refer to Finishes Schedule for
locations
RE-01
Resilient Materials - Vinyl 05-500
Store - A.GF07
FORBO Surestep Original
Product: Original
Colour: Elephant
Code: 171952 Thickness: 2mm
Slip Resistance: R10/Barefoot for wet areas
Alll welded joints in accordance with manufacturers
current written installation instructions, to match selected
colour
Stair Nosings
SN-01
Stair nosing - Concrete
stairs
06-150
LATHAM
Asbraloy Safety Stair Tread Nosing.
Profile: Asbrabloy FA711ST 1428.1-2009 Compliant.
Insert colour: Lumo Luminescent
Position: Stair Tread
Fixing: as per manufacturers recommendations
*To comply with AS1428
Generally to all Concrete Stairs
05-400
CTA AUSTRALIA
PolyStud Plastic Tactile Indicators
Code: TSS002-PP-160
8mm dia x 20mm Drill&Lock Fixing Spigot
Textured top surface and smooth side face.
Style: Spiral top surface.
Comply with AS1428.4.
Generally located at the base
and landing of stairs and ramps
in general public areas and
back of house areas. Refer to
plans for locations.
Tactile indicators
TI-01
Tactile ground surface
indicators
Threshold Strip
TS-01
Threshold Strip
06-150
RAVEN
RP96 Anodised aluminium.
Threshold strip. Screw fix to manufacturer’s
recommendations.
Generally to all external doors
and or where flooring material
changes.
TL-01
Tiles / Pavers
Floor Tiles
05-400
TILES EXPO
Type: Fully vitrified ceramic tile
Colour: Geostone Grigio Natural
Slip Resistance: is R11/B
Size: 600 x 300mm x 10mm
Floor tiles to Wet Areas
generally.
TL-02
Wall Tiles
05-400
TILES EXPO ARCHITECTURAL
Ceramic Tile
Type: Vision - GEN - C1 (matt white)
Colour:
Size: 600 x 300
Wall tiles generally - all
bathrooms.
TL-03
Wall Tiles
05-400
Feature Wall tiles to family
AGROB BUCHTAL
change vilage
Type: Erthenware
Colour: Random Pattern, combination - 1505 Light Blue,
1506 Soft Blue, 1507 Accent Blue, 1508 Deep Blue
Size: 147x147
TL-04
Wall Tiles
05-400
AGROB BUCHTAL
Type: Erthenware
Colour: 1506 Soft Blue
Size: 147x147
Feature Wall tiles to family
change vilage
Included in TL-03
TL-05
Wall Tiles
05-400
AGROB BUCHTAL
Type: Erthenware
Colour: 1507 Accent Blue
Size: 147x147
Feature Wall tiles to family
change vilage
Included in TL-03
TL-06
Wall Tiles
05-400
AGROB BUCHTAL
Type: Erthenware
Colour: 1508 Deep Blue
Size: 147x147
Feature Wall tiles to family
change vilage
Included in TL-03
TL-07
Skirting Tile
05-400
AGROB BUCHTAL
Range: Chroma II Series
Type: Cove Skirting - 31080
Type: External Mitre Pair - 37081
Type: Internal Mitre Pair - 37082
Colour: To match adjacent Wall Tile
AT-01
Acoustic Tile
Waterproof Membranes
Generally to Main Pool hall,
HERAGESIGN
Superfine, 600 x 1200 suspended ceiling system with VK- 25m Pool & WW Pool – wall
and ceiling
10 edge type on approved Knauf furring channel, Top
Cross Rail and suspension rods. All ceiling system
components are to be primed and painted in accordance
with the protectective coating specification after being
level set and tested. Use only heradesign supplied fixing
system.
Colours: TBA
WPM-01
Sheet membrane - subsurface
04-050
SIKA
Sikaproof A-12: TPO Sheet Preapplied Membrane. Roll
width 2.0m.
Fully and permanently bonded composite sheet
waterproofing
membrane system.
SikaProof Tape-150, self-adhesive, internal jointing
tapes based on Butyl-rubber, in 150 mm width.
SikaProof Extape-150, shelf-adhesive, external jointing
tapes based on Butyl-rubber, in 150 mm width.
Installed with Sika Greenstreak Waterbar - Centre Bulb
200mm for construction and/or expansion joints.
Full system installed by manufacturer instructed and
approved contractors in strict accordance with
manufacturer's current written specification.
WPM-03
Internal wet area
membrane - Walls &
Floors
04-050
BASF
PCI Lastogum X membrane.
The selected membrane shall be installed in strict
accordance with the manufacturers written instructions.
Install waterproof membrane reinforcement - PCI PECI
Tape at all corner junctions. Install in accordance with
AS3740.
Floors: This membrane shall be installed to all tiled
amenities areas within aquatic change rooms and
outside the aquatics areas.
Walls: This membrane shall be installed behind all tiled
walls across the site including in aquatic areas up to a
height of 2150mm. Note that this membrane is
compatible with Seccarol 2K.
Regarding the above membrane systems, the floors
slabs and walls must be prepared and primed to receive
the membrane material in strict accordance with the
manufacturer’s recommendations. The slab must have
cured for at least 28 days and must be sufficiency dry to
receive the membrane.
Typically inspections are required after each of the
following actions have been completed;
1.) after floors and walls have been prepared to accept
the membrane primer;
2.) after application of the membrane primer;
3.) after the membrane has been laid prior to covering
over.
WPM-04
Builder's film
04-050
200 micron black polythene sheet waterproof barrier.
WPM-05
Sealant
03-300
To concrete construction joints
SIKA
generally.
Sikaflex-Tank system.
High performance, chemical resistant polyurethane joint
sealant.
System installed in accordance with manufacturer's
current written specification.
WPM-06
Liquid membrane 04-050
Tiled floors to all aquatic
areas, except tiled
change rooms
SUPPLIER CONTACT
NUMBERS
COMPANY
Atkar
Andrews Group
Austim (Australian
Timber Products)
Austral Bricks
Autex
BASF
PCI Seccoral 2K membrane.
The selected membrane shall be installed in strict
accordance with the manufacturers written instructions.
The finished dry layer thickness of the membrane
material must be at least 2mm thick as required by the
manufacturer. Install waterproof membrane
reinforcement - PCI PECI Tape at all corner junctions at
all corner junctions.
The floors slabs and walls must be prepared and primed
to receive the membrane material in strict accordance
with the manufacturer’s recommendations. The slab
must have cured for at least 28 days and must be
sufficiency dry to receive the membrane.
Typically inspections are required after each of the
following actions have been completed;
1.) after floors and walls have been prepared to accept
the membrane primer;
2.) after application of the membrane primer;
3.) after the membrane has been laid prior to covering
over.
CONTACT
TELEPHONE
Travis Parker
Stuart Andrews
Alan Parker
03 9796 3333
0410 749 000
(08) 9409 6111/0457 999 525
Alana Maddock
George Georgiou
9303 4000/ 0404817879
0418 205 702
David Carroll
Justin Dennis
03 9876 2872 / 0419 332 306
0432 684 062
1800 677 052
sales@benchtopcity.com.au
sales@bentglass.com.au
russell@ceramicsolutions.com.au
Barrisol Australia
Bench Top City
Bent & Curved Glass Pty
Ltd
Boral
C/S Group
Capral
Ceramic Solutions
(Agrob Buctal tiles)
Chemind
Rob Capper
Russell Cook
1300 55 25 55
02 8543 4000
08 9302 8500
03 9545 5322 / 0419 113 777
Eral Dettrick
1800 33 44 44
Classic Ceramics
Sallie Boucher
0409 403 711
travis@atkar.com.au
stuart@the andrewsgroup.com.au
www.classicceramics.com.au
Bench Top City
Bolon
Ceramic Solutions
(Agrob Buctal tiles)
Classic Ceramics
CSP Architectural
(Alpolic)
CSR Bradford
CSR Gyprock
Dulux
DPJ Coating Systems
Elite Pool Cover
Eternit Asia panels
Everbright Roofing
Systems Pty Ltd
Fielders
Forbo
Justin Dennis
Stuart Andrews
Russell Cook
0432 684 062
0410749000
0419 113 777
www.benchtopcity.com.au
www.theandrewsgroup.com.au
Sallie Boucher
Kirk Wells
0409 403 711
0425 777 019
www.classicceramics.com.au
Daniel McKeown
Troy Stubbs
Bernard Schenk
Jan Bucknall
Steve Trower
1300 850 305
131 744
03 9263 5803
0418 384 262
0403 300 101
0418965116
(08) 9304 2132/0414 565459
Dean Lovett
Hilton Gaulbert
03 9300 7700
0148 617 961 / 1800 224 471
Gunnersen
GWA Group
(Caroma/Dorma
Supplier)
Hafele
Hufcor (Kyissa)
Hufcor (Operable Wall)
Interface
Johnson Tiles
Keystone Acoustics
Kingspan
Laminex
Locker Group
LouvreTec
MasterFibre
Mei Picchi
Monotek (flooring
systems)
Nellakir (Aust) Pty Ltd
Polyflor
Polysoft Pty Ltd
RBA Group (bathroom
Products)
Regupol
Resene Paint
Reynaers Aluminium
Southern Cross
Spectrum
SPS – Specialty
Plumbing Supplies
Stone Outdoors
Tiles Expo
Viridian
Wattyl
X Position
Woven Image
Biowood Australia
Ben Holod
Melissa Fredericks
03 9647 9911/ 0418336553
0409 763 591
www.equitone.com
http://www.everbrightroofing.com.au
mfredericks@gwagroup.com.au
Troy Stubb
03 9212 2000
03 9338 7400
03 9330 3733
03 9214 0713
www.interface.com
03 9720 4041
02 9604 8813
0420 414 844
mark.playdon@kingspan.com
13 21 36
1800 635 947 / 03 8791 1000
03 9770 4184
07 3376 7288
03 99004222
http://www.meipicchi.com
1800 062 301/ 0418384262
Geoff Toye
Adrian Conrick
Richard Lao
03 9355 7426
0404 817 283
(02) 9620 7231
Tony Merakis or Helen Osman
Simon Griffiths
Sandy Elliott
1300 788 778
02 46240050/ 0420 752 479
07 5512 6611
02 9666 0555
03 9561 9911
1300 786 585
Tyron
Samantha Edel
Mauro Faba
Catherine Lewocki
Mark Playdon
Peter Forrest
Jo
Con Kantis
Darren Morrison
Joseph Keenan
Melvin Fontanilla
(02) 9416 8031
1300303975
08 93288111
0423 820 884
(03) 9688 1287
03 9768 3996
9429 0142/ 0413 752 202
+61 429 77 3363
www.regupol.com.au
www.reynaers.com , info@reynaers.com
http://www.southerncrossceramics.com/
http://www.stoneoutdoors.com.au/
www.tilesexpo.com.au
http://x-position.com.au/
joseph.keenan@wovenimage.con
melvinf@biowoodaustralia.com.au
Product Selection
The naming of particular products in the Schedules indicates products of acceptable quality and design intent that may be approved, but does not mean exclusive preference for products.
Equivalent products may be used. Submit for approval details of proposed products before commencing.
The naming of proprietary products does not reduce or modify the Contractor’s responsibility to comply with the Contract Documents and warrant the work.
Before commencing, verify the correct selection of appropriate products for the substrates and conditions in accordance with the Product Information.
Revision History
Purpose
Issue:
Preliminary Tender
A
1 Tender
Date:
27.02.2015
06.03.2015
Project: 503085 - Leichhardt Park Aquatic Centre, Lilyfield
Client:
Leichhardt Park Aquatic Centre
Notes
This legend and schedule is to be read in conjunctions with the Specification and all other contract schedules.
All painted surfaces to be Dulux, unless otherwise stated.
Aluminium skirtings are to be clear anodised, unless otherwise stated.
All window and glazing framing systems to be Dulux powdercoat PPC-02, unless otherwise stated.
Issue: 2
Date: 07.04.2015
Refer to the Specification for detailed information of all finishes.
Spec
Ref
Code
TRS Description
BA-01
Plumbing Fixtures
Basin - Standard
Spec Description
BA-02
Basin - Standard
CAROMA INDUSTRIES
Carboni II Semi Recessed basin - 1TH
Ceramic White
Code: 865915W
GR-01
Grab Rail - Ambulent
VIRTU
Comfort 450mm x 450mm Grab Rail
Code: 84774545440
Installed according to AS1428
GR-02
Grab Rail - Acc
VIRTU
Virtu Comfort Grab Rail 960x600mm RHS/LHS
Code: 8479467440/8479465440
Installed according to AS1428.1
GR-03
Grab Rail - Acc
VIRTU
Virtu Comfort Grab Rail 300mm
Code: 84730040
Installed according to AS1428.1
GR-04
Grab Rail - Acc
VIRTU
Virtu Comfort Grab Rail 600mm
Code: 84760040
Installed according to AS1428.1
SH-01
Shower Head
Thornthwaite Technologies (Supplier)
RADA
Rada VR2 vandal resistant shower head
Chrome
8L/min
SH-02
Shower Head
DORF
Myriad Fixed Wall Shower
Code: 9154.043A
SH-03
Shower Head - Acc.
VIRTU
Plus Starsafe II Shower Ecojet Neu with Inverted T
Grab Rail RH/LH
Code: 782738/782739
SH-04
Shower Head Concourse
CAROMA
Indus Overhead Rain Shower
Code: 91051C2A
Comments
CAROMA INDUSTRIES
Carboni II Wall basin - 1TH
Ceramic White
Code: 865715W
Requires Caroma Right Angle Shower Arm
Code: 2464.04
SN-01
Sink - Kitchenette
CLARK
Monaco Single End Bowl LHB - 1TH
Code: 5113.1L
SN-02
Sink - Cleaners
CLARK
Cleaners Sink
Code: Y5100
WELS 3 star rated, 8.5L/min
WELS 3-Star (9 l/min)
Image
Rev
TP-01
Mixer Tap
WELS 6 star rated, 5L/min
Thornthwaite Technologies (Supplier)
PRESTO
Presto 2000 time flow tap 7.5sec (Hot and Cold pair)
Chrome
-Tepid taps to public change rooms and crèche. (one
centre hole)
- Tepid and cold supply to members areas - gym
amenities and football club change rooms (two taps on
the basin and no centre hole)
TP-02
Mixer Tap - Acc.
HANSA
Hansa Medica Prado Basin Mixer
Code: 014222760037
Installed according to AS1428
WELS 4-Star (7.5 l/min)
TP-03
Mixer Tap - Kitchen
CAROMA
Sarcoma Sink Mixer
Code: 98025C4A
WELS 4 star, 7.5L/min
TP-04
Shower Mixer
PRESTO
Presto 512 Valve - Timed Flow Control
Code: P31056
TP-05
Shower Mixer - Acc
HANSA
Hansa Medica Prado Shower Mixer
Code: 01470176
Installed according to AS1428
TP-06
Shower Mixer
DORF
Kip Bath/Shower Mixer
Code: 872882C
TP-07
Wall Tap - Cleaners
CAROMA
G Series Exposed Lever Wall Sink Set 115mm
Code: G52430CA
WELS 4 Star rated (7.5L/min)
UR-01
Urinal
1.8L cistern and WELS 3 star rated,
6/3L flush
WC-01
Toilet Suite - Public
CAROMA
Cube Urinal Invisi Series II Suite
nduct In ceiling / Inwall
Code: 771600W
Fitted with Invisi Series II rectangular single flush
custom buttons
Chrome rectangular single flush custom buttons
Code: 237022C
Cisterns to be located in ceiling space above urinals.
Supply and install 900 Long x 600 Wide Ceiling access
panel.
CAROMA INDUSTRIES
Caravelle Close Coupled Suite
Code: 989218
WC-02
Toilet Suite - Ambulent
compliant
CAROMA INDUSTRIES
Caravelle Easy Height Close Coupled Toilet Suite Caravelle Care Double Flap - Anthracite Grey
Code: 989370AG
WELS 4 star rated, 4.5/3L
Meets Ambulant AS1428.1
requirements
WC-03
Toilet Suite - Acc.
CAROMA INDUSTRIES
Care 400 Toilet Suite Suite with Backrest - Colani
Single Flap - Anthracite Grey
Code: 987900BAG
Installed according to AS1428.1
WELS 4 star rated Smartflush Suite
Meets AS1428.1 requirements
WC-06
Toilet Suite - Creche
CAROMA INDUSTRIES
Junior 2000 Connector BI S Trap Suite
Wall Faced
Code: 984251W
WELS 4 star rated, 4.5L/3L
Smartflush
ZIP-01
Zip HydroTap
ZIP
Zip HydroTap
Zip Model: Zip HydroTap G4 BC 160/175
Order Code: HT1704
ZIP-02
Zip Autoboil
ZIP
Zip Autoboil wall mounted unit
Zip Model: Autoboil AB025FX
Order Code: 12054
2
WELS 4 star rated, 4.5/3L Smartflush
Suite
BC-01
Sanitary Fittings
Baby Change
RBA
Koala Baby Change Table
Vertical Wall Mounted Stainless Steel Finish
Code: KB111-SSWM
FS-01
Folding Shower Seat Acc
BRADLEY
Surface Mounted Folding Seat
Model 9558-40
Stainless Steel tubing with White laminate seat bonded
to a phenolic core
HD-01
Hand dryer - Standard
JETDRYER
Jetdryer
Casing: Polycarbonate ABS
Colour finish: Grace White
Filtration: Antibacterial coated PHMG Filter
Installed to product recommendations.
HD-02
Hand dryer - Acc.
RBA
TrimLine Surfaced Mount Accessible Compliant Hand
Dryer
Code: B7128E
Installed to product recommendations.
Installed according to AS1428
MR-01
Wall mirror
Refer to Wet Area elevations & shop
VIRIDIAN DÉCOR MIRROR SAFE
changing room layouts
Frameless
Point fixed through wall lining
Refer to internal elevations for dimensions and setouts
Colour: 4mm clear
PT-01
Paper Towel Dispenser
BRADLEY
Towel Dispenser
Stainless Steel Satin Finish
Tumbler lock
Model 2442 - Recessed
RH-02
Robe Hook
CAROMA
Cosmo Metal Robe Hook
Code:309128C
RH-03
Robe Hook - Acc
VIRTU
Circut Robe Hook with Backplate
Code: 0916C
SD-01
Soap Dispener
BRADLEY
Surface Mounted Liquid Soap Dispenser
Stainless Steel Satin Finish
Model 6562
SD-02
Soap Holder - Acc
BRADLEY
Surface Mounted Soap Dish
Type Regent R021
Surface Mounted
Polished Stainless Steel Finish
SD-03
Soap Holder
BRADLEY
Surface Mounted Soap Dish and Shelf
Type Regent R0941-21-12
Surface Mounted
Polished Stainless Steel Finish
SR-01
Shower Rail - Acc
BRADLEY
Corner Shower Curtain Rail - Standard Size 1200 x
1200 x 600 Ceiling Support
Stainless Steel Finish
Model 953-CNR including
Shower Curtain 1800H x 1200W
Model 9537
TH-01
Toilet Roll Holder Standard
BRADLEY
Jumbo Toilet Tissue Dispenser
Stainless Steel Satin Finish
Surface mounted
Model 5424
TH-02
Toilet Roll Holder - Acc.
BRADLEY
Toilet Tissue Dispenser
Satin Finish
Double roll toilet tissue dispenser.
Model 5234
Installed according to AS1428
PS-01
Toilet partition system
RS-01
Roller Shutters
Roller shutter
RS-02
Tilt Up Door
FLUSH PARTITIONS AUSTRALIA
Hardicolour
18mm Compressed Fibre Cement Sheeting
Colour: Clear two pack polyurethane finish with
compact laminate doors
Doors: 13mm compact laminate - Laminex
Colour: TBC
All support aluminium to be anodised finish including
H200mm legs dynabolted through floor. Partitions to
include all hardware eg coat hooks/ door bumpers,
indicator sets
Dimensions: refer to Architectural drawings.
Generally to all concourse
public/change toilets and showers
Generally to Pool Hall areas
AUSTRAL MONSOON
Austral Monsoon or acceptable equivalent Panorama
E85 aluminium roller shutter.
Slats: Fully solid
600x600 proprietary access panels under motors
typical.
Emergency chain rolled up in ceiling space adjacent to
access panel
Battery backup and connection to FIP for auto open
upon fire alarm activation. Include push to exit button
Finish: Powder coat finish. Colour to be confirmed by
the Superintendent. DFT 100 Microns.
Operation: Motorised (3-Phase). Motor to be fully boxed
in with custom aluminium sealed removable cover.
Battery backup and connection to FIP for auto open
upon fire alarm activation. Include push to exit button.
Include Logic control for swipe interface where
indicated on the door schedule. Allow for keyswitch on
the external side of the door in addition to swipe card
facility.
Battery backup and connection to FIP for auto open
upon fire alarm activation. Include push to exit button
Refer to Door Schedule for sizes
MONARCH DOORS
Renlita Series 3000 two-leaf floataway counterbalanced
door.
Twin leaf counterbalanced aluminium framed panels
with glass infill and hinged horizontally.
Aluminium framed fully glazed door. Viridian VLAM
toughened 10mm thick Grade A safety Glass in
accordance with AS1288. Door shall be suitably braced
to withstand wind loadings in the closed position and
provide minimum deflection in the open and closed
positions.
High alloy grade 904L austenitic stainless steel cables
chains all other internal componentry subject to tension.
Finish: PCC finish to 100 microns
G. Size varies. Refer to drawings and door schedule.
Measure and confirmed on Site prior to manufacture.
H. Counterweights shall be enclosed and protected
using 3mm thick powdercoated aluminium covers and
shall be fixed to the guide channel and wall.
I. Motorised operation. Refer to Electrical Services
documents. Motor 415V-3 Phase Door Drive,
240V reversing contactor and key switch operation.
Pool Equipment
Electrical Applicances Kitchen
REF-02
Refrigerator Undercounter
THERMOMASTER
S/S Bar/ Undercounter Fridge
Model: HR200 s/s
Group 1
Konica Minolta
Colour laser printer, scanner and copier
Code: bizhub C554e
Group 3
CABLE GATE (Matilda Products)
Automated chain gate barrier
Card reader Access Control System
FFC & CoC Staff Secure Car Parks.
Refer Architectural drawings
Interloc
Premium Specification - Wave Locker Doors with
bench seat.
Locker Type Code: G IL High Plinth
Finish to be Nuvex (JTM-01). 316 SS frames for
lockers and seats.
Size: W300mm x D500mm x H1450mm on a 450mm
plinth.
Finish to be Nuvex.
Colour: TBA. Refer to Architectural drawings.
RFID Reader for cards and wrist bands with LINKS
control system. One per locker.
Allow power and data.
Refer Plans. Locations to be
confirmed on site.
* All lockers shall be hard wired to the
LINKS Members electronic system
utilising the Gantner or equivalent
control system. Coordinate with the
Electrical Services documents. RFID
type operation and locks unless noted
otherwise inclusive of associated
software and all required integration
into LINKS system
*All lockers shall be connected to a
proprietary UPS battery backup
system.
Electrical Applicances Audio Visual
PR-01
Printer/ copier/ scanner
CG-01
Landscape
Cable Gate
LK-01
Equipment Other /
Items
Lockers
Product Selection
The naming of particular products in the Schedules indicates products of acceptable quality and design intent that may be approved, but does not mean exclusive preference for products.
Equivalent products may be used. Submit for approval details of proposed products before commencing.
The naming of proprietary products does not reduce or modify the Contractor’s responsibility to comply with the Contract Documents and warrant the work.
Before commencing, verify the correct selection of appropriate products for the substrates and conditions in accordance with the Product Information.
Revision History
Purpose
Issue:
PRELIMINARY TENDER
A
1
TENDER
Date:
27.02.2015
13.03.2015