ATEX Explosion proof proximity card reader EXPROX

MODEL EXPROX-001/AY-K20
ATEX EXPLOSION PROOF PROXIMITY CARD READER
IP66 ATEX proximity card reader Wiegand-RS232 and 125KHz for tank terminal facilities
FEATURES AND BENIFITS
•
Small design, allows easy integration
•
ATEX approval II 2 G/D EEXd IIC T5
•
Includes one (1) explosion proof gland
for entering reader cable .
(Max.900 mtr (2600 baud) away from
door controller).
•
Clear LED indication indicating
acceptation of card. (Green, red)
•
Pre-assembled with nine (9) screw
terminals
Model EXPROX-001/AY-K20
ATEX certified proximity card reader
(Green marine coating is optionally)
Options
MC= Marine coating green colour RAL6024
The model EXPROX-001/AY-K20 is an explosion proof proximity card reader suitable for
applications on tank terminal area or any other area which has ATEX classified zones.
The model EXPROX-001/AY-K20 requires connection to a door controller unit. (Not included
in this part number)
Specifications.
General
Construction
: Die cast aluminium housing . Optionally marine coating RAL6024.
Mounting
: Wall mounted with two bolts M6.
Glands
: One (1) explosion proof gland 3/4" NPT.
Power
: 5-16VDC at 35/55mA (Average/Peak).
Protection
: EEXd IIC T5 as per ATEX and IP66.
Connection
: by screw terminal max 0,5mm2.
Dimensions (ØxL) : 140x130mm (excluding gland and wall bracket)
Shipping weight/net : 4kg/3Kg including bracket and gland.
Card reader
Type reader
: AY-K20B multi-format output reader. Selecable outputs:
Wiegand 26-bit, Clock& data and RS-232 . RF modulation ASK at 125KHz.
Reading distance : 6 cm (passive cards)
Temperature range : -31°C to +63°C. Maximum 95% humidity non condensing.
Indicator
: Acceptance LED multi-colour. Beeper included.
Cable distance
: Max. 900 mtr (2600 Baud) to door controller using standard CAT-5 cable.
PRONOR N.V.
Liefkensstraat 35A
B-9032 GENT
TEL: (+) 32-9-257 08 80
FAX: (+) 32-9-257 08 85
Pub-0003-226a
www.pronorbelgium.com
E-mail:info@pronor.be
EXPLOSION PROOF PROXIMITY CARD READER
FEATURES AND BENIFITS
Model PR500-DC12/EX
Explosion proof proximity card reader
with built in DC12 controller and optionally
green colour marine coating
•
ATEX approval II G. EEXd IIC T6
•
Three (3) explosion proof glands provided
For incoming and outgoing cables.
•
LED indication indicating acceptation of
card. (Green, red, yellow)
•
Door controller circuit (DC12) with output
relay Included and preassembled in
housing.
Options
MC= Marine coating green colour RAL6024
The model PR500-DC12/EX is an explosion proof proximity card reader with built in controller
model DC12. (See datasheet Pub-0003-134 for details of door controller DC12).
The PR500-DC12/EX requires connection to a microprocessor-based segment controller
model SR34iTCP. (See same datasheet Pub-0003-134)
Specifications.
Construction
: Die cast aluminium housing with marine coating RAL6024.
Mounting
: Wall mounted with four bolts M6.
Glands
: Three (3) explosion proof glands.
Power
: 8-30VAC or 8-40V DC at 60mA
Reading distance : 1cm passive cards only.
Temperature range : -30°C to +50°C
Indicator
: Acceptance LED
Protection
: EEXd IIC T6 as per ATEX. Suitable for outdoor use
Dimensions (LxWxH): 290x280x160mm (Including fixation points)
Cable length
: Max. 1,2km to segment controller using Belden cable 9502
Shipping weight
: 11kg
PRONOR N.V.
Liefkensstraat 35A
B-9032 GENT
TEL: (+) 32-9-257 08 80
FAX: (+) 32-9-257 08 85
Pub-0003-156
www.pronorbelgium.com
E-mail:info@pronor.be
EXPLOSION PROOF PROXIMITY CARD READER
IP66 ATEX proximity card reader for tank terminal facilities
FEATURES AND BENIFITS
•
ATEX approval II 2 G/D EEXd IIC T6
•
Includes one (1) explosion proof gland
M16 for entering reader cable .
(Max.125mtr away from door controller).
•
Clear LED indication indicating
acceptation of card. (Green, red and
amber)
•
Pre-assembled with nine (9) terminals
Model PR-15001/R10/EX
Explosion proof proximity card reader
(Green marine coating is optionally)
Options
MC= Marine coating green colour RAL6024
The model PR-15001/R10/EX is an explosion proof proximity card reader suitable for
applications on tank terminal area or any other area which has ATEX classified zones.
The PR-15001/R10/EX requires connection to a door controller unit. (Not included in this part
number)
Specifications.
Reader
Model
Protocol
Communiactions
Reading distance
Power
Cable length
Indicator
: HID R10 (900N)
: MIFARE®. Transmit frequency 13.56MHz.
: Wiegand/Clock-and-Data interface
: 6cm (passive cards)
: 10-16VDC at 80 / 300mA (Average/Peak)
: Max. 125 meter to door controller using cable ALPHA 1295 (22AWG)
: Acceptance LED 3-colour
Enclosure
Construction
Mounting
Glands
Temperature range
: Grey die cast aluminium housing . Optionally marine coating RAL6024.
: Wall mounted with four bolts M12.
: One (1) explosion proof gland M16.
: -35°C to +65°C
Protection
: EEXd IIC T6 as per ATEX and IP66.
Dimensions (LxWxH): 230x280x154mm (Including fixation points)
Shipping weight/net : 10kg/8Kg
PRONOR N.V.
Liefkensstraat 35A
B-9032 GENT
TEL: (+) 32-9-257 08 80
FAX: (+) 32-9-257 08 85
Pub-0003-175
www.pronorbelgium.com
E-mail:info@pronor.be