MODEL EXPROX-001/AY-K20 ATEX EXPLOSION PROOF PROXIMITY CARD READER IP66 ATEX proximity card reader Wiegand-RS232 and 125KHz for tank terminal facilities FEATURES AND BENIFITS • Small design, allows easy integration • ATEX approval II 2 G/D EEXd IIC T5 • Includes one (1) explosion proof gland for entering reader cable . (Max.900 mtr (2600 baud) away from door controller). • Clear LED indication indicating acceptation of card. (Green, red) • Pre-assembled with nine (9) screw terminals Model EXPROX-001/AY-K20 ATEX certified proximity card reader (Green marine coating is optionally) Options MC= Marine coating green colour RAL6024 The model EXPROX-001/AY-K20 is an explosion proof proximity card reader suitable for applications on tank terminal area or any other area which has ATEX classified zones. The model EXPROX-001/AY-K20 requires connection to a door controller unit. (Not included in this part number) Specifications. General Construction : Die cast aluminium housing . Optionally marine coating RAL6024. Mounting : Wall mounted with two bolts M6. Glands : One (1) explosion proof gland 3/4" NPT. Power : 5-16VDC at 35/55mA (Average/Peak). Protection : EEXd IIC T5 as per ATEX and IP66. Connection : by screw terminal max 0,5mm2. Dimensions (ØxL) : 140x130mm (excluding gland and wall bracket) Shipping weight/net : 4kg/3Kg including bracket and gland. Card reader Type reader : AY-K20B multi-format output reader. Selecable outputs: Wiegand 26-bit, Clock& data and RS-232 . RF modulation ASK at 125KHz. Reading distance : 6 cm (passive cards) Temperature range : -31°C to +63°C. Maximum 95% humidity non condensing. Indicator : Acceptance LED multi-colour. Beeper included. Cable distance : Max. 900 mtr (2600 Baud) to door controller using standard CAT-5 cable. PRONOR N.V. Liefkensstraat 35A B-9032 GENT TEL: (+) 32-9-257 08 80 FAX: (+) 32-9-257 08 85 Pub-0003-226a www.pronorbelgium.com E-mail:info@pronor.be EXPLOSION PROOF PROXIMITY CARD READER FEATURES AND BENIFITS Model PR500-DC12/EX Explosion proof proximity card reader with built in DC12 controller and optionally green colour marine coating • ATEX approval II G. EEXd IIC T6 • Three (3) explosion proof glands provided For incoming and outgoing cables. • LED indication indicating acceptation of card. (Green, red, yellow) • Door controller circuit (DC12) with output relay Included and preassembled in housing. Options MC= Marine coating green colour RAL6024 The model PR500-DC12/EX is an explosion proof proximity card reader with built in controller model DC12. (See datasheet Pub-0003-134 for details of door controller DC12). The PR500-DC12/EX requires connection to a microprocessor-based segment controller model SR34iTCP. (See same datasheet Pub-0003-134) Specifications. Construction : Die cast aluminium housing with marine coating RAL6024. Mounting : Wall mounted with four bolts M6. Glands : Three (3) explosion proof glands. Power : 8-30VAC or 8-40V DC at 60mA Reading distance : 1cm passive cards only. Temperature range : -30°C to +50°C Indicator : Acceptance LED Protection : EEXd IIC T6 as per ATEX. Suitable for outdoor use Dimensions (LxWxH): 290x280x160mm (Including fixation points) Cable length : Max. 1,2km to segment controller using Belden cable 9502 Shipping weight : 11kg PRONOR N.V. Liefkensstraat 35A B-9032 GENT TEL: (+) 32-9-257 08 80 FAX: (+) 32-9-257 08 85 Pub-0003-156 www.pronorbelgium.com E-mail:info@pronor.be EXPLOSION PROOF PROXIMITY CARD READER IP66 ATEX proximity card reader for tank terminal facilities FEATURES AND BENIFITS • ATEX approval II 2 G/D EEXd IIC T6 • Includes one (1) explosion proof gland M16 for entering reader cable . (Max.125mtr away from door controller). • Clear LED indication indicating acceptation of card. (Green, red and amber) • Pre-assembled with nine (9) terminals Model PR-15001/R10/EX Explosion proof proximity card reader (Green marine coating is optionally) Options MC= Marine coating green colour RAL6024 The model PR-15001/R10/EX is an explosion proof proximity card reader suitable for applications on tank terminal area or any other area which has ATEX classified zones. The PR-15001/R10/EX requires connection to a door controller unit. (Not included in this part number) Specifications. Reader Model Protocol Communiactions Reading distance Power Cable length Indicator : HID R10 (900N) : MIFARE®. Transmit frequency 13.56MHz. : Wiegand/Clock-and-Data interface : 6cm (passive cards) : 10-16VDC at 80 / 300mA (Average/Peak) : Max. 125 meter to door controller using cable ALPHA 1295 (22AWG) : Acceptance LED 3-colour Enclosure Construction Mounting Glands Temperature range : Grey die cast aluminium housing . Optionally marine coating RAL6024. : Wall mounted with four bolts M12. : One (1) explosion proof gland M16. : -35°C to +65°C Protection : EEXd IIC T6 as per ATEX and IP66. Dimensions (LxWxH): 230x280x154mm (Including fixation points) Shipping weight/net : 10kg/8Kg PRONOR N.V. Liefkensstraat 35A B-9032 GENT TEL: (+) 32-9-257 08 80 FAX: (+) 32-9-257 08 85 Pub-0003-175 www.pronorbelgium.com E-mail:info@pronor.be
© Copyright 2024