Dometic is a customer driven, world-leading provider of innovative leisure products for the caravan, motorhome and marine markets. Dometic offers a complete range of air conditioners, refrigerators, awnings, cookers, sanitation systems, lighting, windows, doors and other equipment that makes leisure life more comfortable away from home. Dometic also provides refrigerators for specific use in hotel rooms, offices, and for storage of medical products and wine along with comfort products designed for the over-the-road truck market. Dometic's products are sold in almost 100 countries and are produced mainly in Dometic's own production facilities around the world. Dometic has more than 4,400 employees. Dometic Environmental Corporation P.O. Box 15299 Richmond,VA 23227 Phone: 804-746-1313 Fax: 804-746-7248 Email: sales@DometicTruck.com Website: www.DometicTruck.com PATENTS 7,171,822 • 7,234,315 B2 • 7,140,192 • 7,316,119 • 7,237,397 B2 03-10-08 L2522 Dometic APU-Based Auxiliary Air Solutions D Dometic Environmental Corporation, with a 45+ year heritage in rugged HVAC technology for harsh-environment applications, has developed a range of auxiliary air conditioning and heating solutions to meet the ✦ 7,000, 10,000 and 14,000 BTU capacities for increasing demand for engine-off comfort control in the trucking industry. all size sleepers • Self-contained package units You can count on Dometic for thoroughly engineered products designed for • Patented split systems with reusable the harshest over-the-road conditions backed by unmatched factory support precharged refrigerant linesets ✦ Heating options and after-sale service. That’s why so many leading APU manufacturers currently specify or recommend Dometic HVAC with their products for the trucking market. • 1- 4 KW built-in electric heat modules • Interface with installed diesel-fire heaters ✦ No special tools required to install ✦ Turnkey package includes all components needed to complete installation ✦ Backed by extensive application engineering support and nationwide service ✦ Designed and built for over-the-road conditions and thoroughly field-tested In this booklet, we’ll explain all aspects of selecting, specifying, operating and maintaining your APU-powered auxiliary air system from Dometic. We encourage you to read this information carefully to help you make decisions. If you have any questions, please call us and we’ll be delighted to help you. THE BASICS The basic principle of an air conditioner is the transfer of heat from one place to another – in this case from the inside of your vehicle to the outside. This is accomplished by absorbing heat from the inside air into a refrigerant gas flowing through an evaporator coil. The refrigerant is then pumped to a condenser, where the heat is released to the outside air. The refrigerant, a chemical with a low evaporation temperature, flows around a closed loop, driven and pressurized by a compressor. As a part of the cooling process, the air conditioner also removes moisture from the inside air, which makes the area feel more comfortable and keeps the compartment dry and mildew-free. A belt-driven compressor on the truck’s engine supplies air conditioning whenever the engine is running. To keep the driver comfortable when the engine is shut down, it is necessary to have a separate auxiliary air conditioning system that uses an alternative source of power. The auxiliary air system runs on 115 Volt AC power, which can be supplied by an onboard diesel genset, often referred to as an auxiliary power unit, from a shorepower connection when an external AC power source is available or in some cases from the truck’s batteries using an inverter to convert the 12 Volt battery output into usable 115 Volt AC power. In this booklet we will focus on the APU-based solutions. In the next chapter we will provide an overview of your air conditioning choices. air conditioning choices There are two basic types of auxiliary air systems: Self-contained unit installed under bunk. • Self-contained “package” units • Split systems The self-contained unit is designed to be wholly mounted inside the truck, usually under a berth or seat or inside a side storage locker. All of the air conditioning components, including the compressor, condenser, evaporator, blower and power supply, are mounted on a single low-profile chassis with an aluminum cover. The system’s closed refrigerant loop is precharged and sealed at the factory. Inside air is pulled across the evaporator coil, and cooled air is blown through a flexible duct to a discharge grill for discharge into the living area. Hot air is discharged from the condenser through cutouts in the floorboard. Dometic’s patented split systems consist of two separate modules. The outside unit contains the condenser and cooling fan. It can be bolted horizontally to the underside or vertically to the back of the sleeper. The inside unit contains the compressor, evaporator, blower, power-logic box and other associated components.The compressor is covered by a sheet-metal cover. The inside unit is mounted under a berth or seat or in a side storage locker. The two units are connected by reusable precharged quick-connect refrigerant linesets. The system is designed so that both units automatically charge to the correct refrigerant pressure as soon as the linesets are connected. No special tools are required. Split system inside unit under bunk. Each approach offers advantages and disadvantages. A self-contained unit is simpler to install and maintain, since it does not have any external refrigerant lines. It is also less expensive than a split system of the same BTU capacity. On the other hand, it takes more interior space, and it requires cutting holes in the floor for air to flow to and from the condenser. A split system, on the other hand, has more installation flexibility and uses less interior space. It also is quieter, since the condenser fan is located outside the truck. Both types of air conditioning systems are available with a selection of built-in electrical heat modules. The heat is blown through the same ducts and grills and controlled by the same thermostat. They can also be used in conjunction with a dieselfired heater if desired, under control of the same thermostat. Split system external condenser. *Under normal conditions. Whichever type of system you select, it will come with ducts, grills, condensate drains, thermostat controls and electrical wiring. Heating Capacity Application* 1.0 KW 48 in. sleeper 2.0 KW 60 in. sleeper 2.5 KW 72 in. sleeper 4.0 KW two stage 60 or 72 in. sleeper in cold climates Split Systems Model ECEQ7 Cool Capacity Heat Capacity (BTU) 7,000 Control Height Width Length (in.) (in.) (in.) Internal Unit - Evaporator/Heater/Compressor Weight (lb.) Cool Amps Heat Amps Refrigerant 7.3 n/a R417a Cooling only Smart digital 11.75 10.25 19.25 53 EHCEQ7 7,000 1 KW Smart digital 11.75 10.25 19.25 53 7.3 8.2 R417a ECEQ10 10,000 Cooling only Smart digital 11.63 11.12 20.19 60 11.8 n/a R417a EHCEQ10 10,000 7500 BTU Smart digital 11.63 11.12 20.19 60 11.8 1.0 R417a EHCEQ10 10,000 1.5 KW Smart digital 11.63 11.12 20.19 62 11.8 13 R417a EHCEQ10 10,000 2 KW Smart digital 11.63 11.12 20.19 62 11.8 17 R417a ECEQ14 14,000 Cooling only Smart digital 11.69 13 22 64 14.5 n/a R417a EHCEQ14 14,000 1.5KW Smart digital 11.69 13 22 65 14.5 13 R417a EHCEQ14 14,000 2.5 KW Smart digital 11.69 13 22 65 14.5 21 R417a EHCEQ14 14,000 2.5 KW, 2-stage Smart digital 11.69 13 22 65 14.5 11.4 + 10.4 R417a EHCEQ14 14,000 4 KW, 2-stage Smart digital 11.69 13 22 65 14.5 23.2 + 12.1 R417a External Unit - Condenser ACCD7 7,000 n/a n/a 6.125 11.3125 21.875 10 n/a n/a R417a ACCE10 10,000 n/a n/a 6.125 12.5 24.5 12 n/a n/a R417a ACCE14 14,000 n/a n/a 6.625 12.5 24.5 13 n/a n/a R417a n/a R22 Self-Contained Units ASCF7 7,000 Cooling only Mechanical 12.5 15.25 21.5 62 8.5 ASCEQ7 7,000 Cooling only Smart digital 11.94 17.75 24 70 8.9 n/a R417a ASCEQ7 7,000 7500 BTU Espar ready Smart digital 11.94 17.75 24 70 8.9 1.8 R417a ASCEQ7 7,000 1 KW Smart digital 11.94 17.75 24 71 8.9 9.5 R417a ASCEQ7 7,000 1.5 KW Smart digital 11.94 17.75 24 71 8.9 13.4 R417a ASCDQ10 10,000 Cooling only Smart digital 12.5 20.87 28.25 91 12.9 n/a R22 ASCDQ10 10,000 1.5 KW Smart digital 12.5 20.87 28.25 92 12.9 13.9 R22 ASCDQ10 10,000 2 KW Smart digital 12.5 20.87 28.25 92 12.9 18.2 R22 ASCDQ14 14,000 2 KW Smart digital 12.5 20.87 31.5 104 15.7 19 R22 ASCDQ14 14,000 2.5 KW Smart digital 12.5 20.87 31.5 104 15.7 23 R22 SPECIFYING THE SYSTEM About Insulation. Auxiliary Power UniT Before we go any further, let’s talk briefly about insulation. Most truck sleepers today are insulated with a value of When running the air conditioner from an APU, the genset must be large enough to start and run the air conditioning approximately R 1 to R 1.25. Compare this to the insulation of R 30 that is required in most new housing contruc- unit as well as any other electrical appliances you may wish to run at the same time. This can be complicated, since tion. Even the “cold-weather packages” offered with some new trucks only have insulation values of R 2. TMC gensets from different manufacturers may vary considerably in their output characteristics. If you measure the output recommended practices call for R 4.2 as a standard insulation package and greater than R 4.6 in a premium package. of two gensets rated by their manufacturers at 2.5 Kilowatts, you will observe them to be very different. This standard, once adopted by the industry, will go a long way toward improving the performance of auxiliary air conditioning and heating systems. It’s also important to allow for the surge capacity needed to start the air conditioning compressor. Each time the compressor cycles on, there is a short electrical surge that is equal to about four times the normal running amps If you are buying a new truck, you should order it with additional insulation. There are also a number of measures for several hundred milliseconds. Most good-quality gensets are designed to support these short surges without you can take to reduce the heat load in your truck. If you have skylights, cover them. Insulate the floors with foam tripping off the line. under the carpet. Add insulation to the doors. Get heavy-duty curtains to separate the sleeper from the cab. Cover the windshield and windows with reflective shades when parked. Park in the shade whenever possible. Switch off heat-producing appliances in the sleeper. Capacity BTU 7,000 Genset Minimum Output (Continuous KW) Genset Minimum Surge Amps 2.0 38 10,000 2.5 60 14,000 3.0 70 Air Conditioning Units Your first step will be determining the type of air conditioning units (split or self-contained) to meet your requirements Shorepower and space constraints, then sizing the units to meet the expected heat load. Although there are relatively few shorepower hookups available at truck stops, rest stops and terminals, these will Sizing the system can be a complicated affair, since it depends on a number of factors, such as the size and shape of become more readily available in the future. the sleeper, the amount of insulation (see above), the size and location of windows, the color of the truck (darker colors absorb more heat) and the ambient temperature outside.The following guidelines are based on TMC recom- TMC recommends a minimum 20-amp circuit for shorepower connections. You should use any heavy-duty power mendations under “average” conditions. If you are operating in very hot regions, you may need to consider extra cord with a standard three-prong plug. Remember that there will be a voltage drop across the cord, so you should capacity. use the minimum length necessary to reach your outside power source. 7,000 BTU Day cab or small sleeper up to 48 in. with flat roof 10,000 BTU Mid-size 60-in. sleeper with low or mid-height roof 14,000 BTU Full-size 60-72-in. sleeper with high-rise roof 12 gauge Up to 25 ft. 10 gauge Up to 50 ft. INSTALLING, OPERATING AND MAINTAINING THE SYSTEM USEFUL links Installation Dometic will provide detailed installation instructions with your system. You should make sure you understand these instructions and follow them completely. Note that the APU must be set to deliver 115 Volt 60 Hz output in order for the air conditioner to function properly. Check with your APU supplier. Controls The Dometic auxiliary air system comes with a standard digital thermostat/display unit. Operation is intuitive and easy, with up and down arrows to adjust the setpoint and fan speed. Optimizing Performance To improve the air conditioner’s performance on a hot day, you can reduce the heat load by parking in a shaded area, covering the windows with reflective shades to block out direct sunlight and pulling the curtain between the sleeper and cab. Make sure windows and doors are tightly closed, and turn off any other heat-producing appliances. Operation and Maintenance You should inspect and clean the air filter regularly to ensure good airflow across the evaporator coils. You will find the filter in the return air path, either directly behind the grill or in front of the evaporator coil. Make sure you do not block the airflow between the return air grill and evaporator coil with pillows, blankets, papers or other objects. Check the condensate drain often to make sure water is draining properly. Make sure the drain fittings do not get clogged. Note that the drain hose under the truck should be tied in a loop so as to form a natural trap. This will help prevent outside air and exhaust discharge from getting inside. If you have a split system with external condensing unit, make sure you inspect and clean any debris from condenser coil area to ensure good air flow. Dometic’s auxiliary air systems, both self-contained and split, are designed so that you should never need to recharge the refrigerant loop under normal circumstances. If the refrigerant level ever needs to be adjusted, federal law requires that it must be done by an EPA-licensed HVAC technician with the proper tools to avoid accidental discharge of any refrigerant gas into the air. Occasionally check for chafe on outside wires and refrigerant lines (split systems). Dometic Environmental Corporation www.DometicTruck.com American Transportation Research Institute www.atri-online.org ATA Green Truck Intitiative www.greentruck.com ATA Technology and Maintenance Council (TMC) www.truckline.com/issues/governmentpolicy/environment California Air Resources Board www.arb.ca.gov Canadian Office of Energy Efficiency http://oee.nrcan.gc.ca/transportation/fleetsmart.cfm Environmental Protection Agency SmartWay Program www.epa.gov/smartway Pennsylvania Office of Energy and Technology Development www.dep.state.pa.us U.S. Department of Energy Clean Cities Program www.eere.energy.gov/cleancities West Coast Collaborative www.westcoastdiesel.org
© Copyright 2024