Dometic is a customer driven, world-leading provider of innovative leisure... the caravan, motorhome and marine markets. Dometic offers a complete...

Dometic is a customer driven, world-leading provider of innovative leisure products for
the caravan, motorhome and marine markets. Dometic offers a complete range of air
conditioners, refrigerators, awnings, cookers, sanitation systems, lighting, windows, doors
and other equipment that makes leisure life more comfortable away from home.
Dometic also provides refrigerators for specific use in hotel rooms, offices, and for storage
of medical products and wine along with comfort products designed for the over-the-road
truck market. Dometic's products are sold in almost 100 countries and are produced
mainly in Dometic's own production facilities around the world. Dometic has more than
4,400 employees.
Dometic Environmental Corporation
P.O. Box 15299
Richmond,VA 23227
Phone: 804-746-1313 Fax: 804-746-7248
Email: sales@DometicTruck.com
Website: www.DometicTruck.com
PATENTS
7,171,822 • 7,234,315 B2 • 7,140,192 • 7,316,119 • 7,237,397 B2
03-10-08 L2522
Dometic APU-Based Auxiliary Air Solutions
D
Dometic Environmental Corporation, with a 45+ year heritage in rugged
HVAC technology for harsh-environment applications, has developed a
range of auxiliary air conditioning and heating solutions to meet the
✦
7,000, 10,000 and 14,000 BTU capacities for
increasing demand for engine-off comfort control in the trucking industry.
all size sleepers
• Self-contained package units
You can count on Dometic for thoroughly engineered products designed for
• Patented split systems with reusable
the harshest over-the-road conditions backed by unmatched factory support
precharged refrigerant linesets
✦
Heating options
and after-sale service. That’s why so many leading APU manufacturers
currently specify or recommend Dometic HVAC with their products for the
trucking market.
• 1- 4 KW built-in electric heat
modules
• Interface with installed diesel-fire heaters
✦
No special tools required to install
✦ Turnkey
package includes all components
needed to complete installation
✦
Backed by extensive application engineering
support and nationwide service
✦
Designed and built for over-the-road
conditions and thoroughly field-tested
In this booklet, we’ll explain all aspects of selecting, specifying, operating and
maintaining your APU-powered auxiliary air system from Dometic. We
encourage you to read this information carefully to help you make decisions.
If you have any questions, please call us and we’ll be delighted to help you.
THE BASICS
The basic principle of an air conditioner is the transfer of heat from one place to another – in this case from the
inside of your vehicle to the outside. This is accomplished by absorbing heat from the inside air into a refrigerant
gas flowing through an evaporator coil. The refrigerant is then pumped to a condenser, where the heat is released
to the outside air. The refrigerant, a chemical with a low evaporation temperature, flows around a closed loop, driven
and pressurized by a compressor. As a part of the cooling process, the air conditioner also removes moisture from
the inside air, which makes the area feel more comfortable and keeps the compartment dry and mildew-free.
A belt-driven compressor on the truck’s engine supplies air conditioning whenever the engine is running. To keep
the driver comfortable when the engine is shut down, it is necessary to have a separate auxiliary air conditioning
system that uses an alternative source of power.
The auxiliary air system runs on 115 Volt AC power, which can be supplied by an onboard diesel genset, often referred
to as an auxiliary power unit, from a shorepower connection when an external AC power source is available or in
some cases from the truck’s batteries using an inverter to convert the 12 Volt battery output into usable 115 Volt
AC power. In this booklet we will focus on the APU-based solutions. In the next chapter we will provide an
overview of your air conditioning choices.
air conditioning choices
There are two basic types of auxiliary air systems:
Self-contained unit installed under bunk.
• Self-contained “package” units
• Split systems
The self-contained unit is designed to be wholly mounted inside
the truck, usually under a berth or seat or inside a side storage
locker. All of the air conditioning components, including the compressor, condenser, evaporator, blower and power supply, are
mounted on a single low-profile chassis with an aluminum cover.
The system’s closed refrigerant loop is precharged and sealed at
the factory. Inside air is pulled across the evaporator coil, and
cooled air is blown through a flexible duct to a discharge grill for
discharge into the living area. Hot air is discharged from the condenser through cutouts in the floorboard.
Dometic’s patented split systems consist of two separate modules. The outside unit contains the condenser and
cooling fan. It can be bolted horizontally to the underside or vertically to the back of the sleeper. The inside unit
contains the compressor, evaporator, blower, power-logic box and other associated components.The compressor is
covered by a sheet-metal cover. The inside unit is mounted
under a berth or seat or in a side storage locker. The two
units are connected by reusable precharged quick-connect
refrigerant linesets. The system is designed so that both units
automatically charge to the correct refrigerant pressure as
soon as the linesets are connected. No special tools are
required.
Split system inside unit under bunk.
Each approach offers advantages and disadvantages. A self-contained unit is simpler to install and maintain, since it does not
have any external refrigerant lines. It is also less expensive
than a split system of the same BTU capacity. On the other
hand, it takes more interior space, and it requires cutting
holes in the floor for air to flow to and from the condenser. A
split system, on the other hand, has more installation flexibility
and uses less interior space. It also is quieter, since the condenser fan is located outside the truck.
Both types of air conditioning systems are available with a
selection of built-in electrical heat modules. The heat is blown
through the same ducts and grills and controlled by the same
thermostat. They can also be used in conjunction with a dieselfired heater if desired, under control of the same thermostat.
Split system external condenser.
*Under normal conditions.
Whichever type of system you
select, it will come with ducts,
grills, condensate drains, thermostat controls and electrical wiring.
Heating Capacity
Application*
1.0 KW
48 in. sleeper
2.0 KW
60 in. sleeper
2.5 KW
72 in. sleeper
4.0 KW two stage
60 or 72 in. sleeper in cold climates
Split Systems
Model
ECEQ7
Cool Capacity Heat Capacity
(BTU)
7,000
Control
Height
Width
Length
(in.)
(in.)
(in.)
Internal Unit - Evaporator/Heater/Compressor
Weight
(lb.)
Cool
Amps
Heat
Amps
Refrigerant
7.3
n/a
R417a
Cooling only
Smart digital
11.75
10.25
19.25
53
EHCEQ7
7,000
1 KW
Smart digital
11.75
10.25
19.25
53
7.3
8.2
R417a
ECEQ10
10,000
Cooling only
Smart digital
11.63
11.12
20.19
60
11.8
n/a
R417a
EHCEQ10
10,000
7500 BTU
Smart digital
11.63
11.12
20.19
60
11.8
1.0
R417a
EHCEQ10
10,000
1.5 KW
Smart digital
11.63
11.12
20.19
62
11.8
13
R417a
EHCEQ10
10,000
2 KW
Smart digital
11.63
11.12
20.19
62
11.8
17
R417a
ECEQ14
14,000
Cooling only
Smart digital
11.69
13
22
64
14.5
n/a
R417a
EHCEQ14
14,000
1.5KW
Smart digital
11.69
13
22
65
14.5
13
R417a
EHCEQ14
14,000
2.5 KW
Smart digital
11.69
13
22
65
14.5
21
R417a
EHCEQ14
14,000
2.5 KW, 2-stage
Smart digital
11.69
13
22
65
14.5
11.4 + 10.4
R417a
EHCEQ14
14,000
4 KW, 2-stage
Smart digital
11.69
13
22
65
14.5
23.2 + 12.1
R417a
External Unit - Condenser
ACCD7
7,000
n/a
n/a
6.125
11.3125
21.875
10
n/a
n/a
R417a
ACCE10
10,000
n/a
n/a
6.125
12.5
24.5
12
n/a
n/a
R417a
ACCE14
14,000
n/a
n/a
6.625
12.5
24.5
13
n/a
n/a
R417a
n/a
R22
Self-Contained Units
ASCF7
7,000
Cooling only
Mechanical
12.5
15.25
21.5
62
8.5
ASCEQ7
7,000
Cooling only
Smart digital
11.94
17.75
24
70
8.9
n/a
R417a
ASCEQ7
7,000
7500 BTU
Espar ready
Smart digital
11.94
17.75
24
70
8.9
1.8
R417a
ASCEQ7
7,000
1 KW
Smart digital
11.94
17.75
24
71
8.9
9.5
R417a
ASCEQ7
7,000
1.5 KW
Smart digital
11.94
17.75
24
71
8.9
13.4
R417a
ASCDQ10
10,000
Cooling only
Smart digital
12.5
20.87
28.25
91
12.9
n/a
R22
ASCDQ10
10,000
1.5 KW
Smart digital
12.5
20.87
28.25
92
12.9
13.9
R22
ASCDQ10
10,000
2 KW
Smart digital
12.5
20.87
28.25
92
12.9
18.2
R22
ASCDQ14
14,000
2 KW
Smart digital
12.5
20.87
31.5
104
15.7
19
R22
ASCDQ14
14,000
2.5 KW
Smart digital
12.5
20.87
31.5
104
15.7
23
R22
SPECIFYING THE SYSTEM
About Insulation.
Auxiliary Power UniT
Before we go any further, let’s talk briefly about insulation. Most truck sleepers today are insulated with a value of
When running the air conditioner from an APU, the genset must be large enough to start and run the air conditioning
approximately R 1 to R 1.25. Compare this to the insulation of R 30 that is required in most new housing contruc-
unit as well as any other electrical appliances you may wish to run at the same time. This can be complicated, since
tion. Even the “cold-weather packages” offered with some new trucks only have insulation values of R 2. TMC
gensets from different manufacturers may vary considerably in their output characteristics. If you measure the output
recommended practices call for R 4.2 as a standard insulation package and greater than R 4.6 in a premium package.
of two gensets rated by their manufacturers at 2.5 Kilowatts, you will observe them to be very different.
This standard, once adopted by the industry, will go a long way toward improving the performance of auxiliary air
conditioning and heating systems.
It’s also important to allow for the surge capacity needed to start the air conditioning compressor. Each time the
compressor cycles on, there is a short electrical surge that is equal to about four times the normal running amps
If you are buying a new truck, you should order it with additional insulation. There are also a number of measures
for several hundred milliseconds. Most good-quality gensets are designed to support these short surges without
you can take to reduce the heat load in your truck. If you have skylights, cover them. Insulate the floors with foam
tripping off the line.
under the carpet. Add insulation to the doors. Get heavy-duty curtains to separate the sleeper from the cab.
Cover the windshield and windows with reflective shades when parked. Park in the shade whenever possible.
Switch off heat-producing appliances in the sleeper.
Capacity
BTU
7,000
Genset Minimum Output
(Continuous KW)
Genset Minimum Surge
Amps
2.0
38
10,000
2.5
60
14,000
3.0
70
Air Conditioning Units
Your first step will be determining the type of air conditioning units (split or self-contained) to meet your requirements
Shorepower
and space constraints, then sizing the units to meet the expected heat load.
Although there are relatively few shorepower hookups available at truck stops, rest stops and terminals, these will
Sizing the system can be a complicated affair, since it depends on a number of factors, such as the size and shape of
become more readily available in the future.
the sleeper, the amount of insulation (see above), the size and location of windows, the color of the truck (darker
colors absorb more heat) and the ambient temperature outside.The following guidelines are based on TMC recom-
TMC recommends a minimum 20-amp circuit for shorepower connections. You should use any heavy-duty power
mendations under “average” conditions. If you are operating in very hot regions, you may need to consider extra
cord with a standard three-prong plug. Remember that there will be a voltage drop across the cord, so you should
capacity.
use the minimum length necessary to reach your outside power source.
7,000 BTU
Day cab or small sleeper up to 48 in. with flat roof
10,000 BTU
Mid-size 60-in. sleeper with low or mid-height roof
14,000 BTU
Full-size 60-72-in. sleeper with high-rise roof
12 gauge
Up to 25 ft.
10 gauge
Up to 50 ft.
INSTALLING, OPERATING
AND MAINTAINING THE SYSTEM
USEFUL links
Installation
Dometic will provide detailed installation instructions with your system. You should make sure you understand
these instructions and follow them completely.
Note that the APU must be set to deliver 115 Volt 60 Hz output in order for the air conditioner to function properly. Check with your APU supplier.
Controls
The Dometic auxiliary air system comes with a standard digital thermostat/display unit. Operation is intuitive and
easy, with up and down arrows to adjust the setpoint and fan speed.
Optimizing Performance
To improve the air conditioner’s performance on a hot day, you can reduce the heat load by parking in a shaded
area, covering the windows with reflective shades to block out direct sunlight and pulling the curtain between the
sleeper and cab. Make sure windows and doors are tightly closed, and turn off any other heat-producing appliances.
Operation and Maintenance
You should inspect and clean the air filter regularly to ensure good airflow across the evaporator coils. You will find
the filter in the return air path, either directly behind the grill or in front of the evaporator coil.
Make sure you do not block the airflow between the return air grill and evaporator coil with pillows, blankets,
papers or other objects.
Check the condensate drain often to make sure water is draining properly. Make sure the drain fittings do not get
clogged. Note that the drain hose under the truck should be tied in a loop so as to form a natural trap. This will
help prevent outside air and exhaust discharge from getting inside.
If you have a split system with external condensing unit, make sure you inspect and clean any debris from condenser
coil area to ensure good air flow.
Dometic’s auxiliary air systems, both self-contained and split, are designed so that you should never need to
recharge the refrigerant loop under normal circumstances. If the refrigerant level ever needs to be adjusted, federal
law requires that it must be done by an EPA-licensed HVAC technician with the proper tools to avoid accidental
discharge of any refrigerant gas into the air.
Occasionally check for chafe on outside wires and refrigerant lines (split systems).
Dometic Environmental Corporation
www.DometicTruck.com
American Transportation Research Institute
www.atri-online.org
ATA Green Truck Intitiative
www.greentruck.com
ATA Technology and Maintenance Council (TMC)
www.truckline.com/issues/governmentpolicy/environment
California Air Resources Board
www.arb.ca.gov
Canadian Office of Energy Efficiency
http://oee.nrcan.gc.ca/transportation/fleetsmart.cfm
Environmental Protection Agency SmartWay Program
www.epa.gov/smartway
Pennsylvania Office of Energy and Technology Development
www.dep.state.pa.us
U.S. Department of Energy Clean Cities Program
www.eere.energy.gov/cleancities
West Coast Collaborative
www.westcoastdiesel.org