WinMOD System WinMOD Platform System Version Software 7.0 7.0 Mewes & Partner Page 0 Real-time Simulation Center for Automation What is new in WinMOD 7.0 ? Dear Customer, we are pleased to present to you the latest version of our real-time simulation and software testing platform WinMOD 7.0. In recent years, much functionality of WinMOD proved stable, versatile and in fact ahead of its time. Even so, several new developments were incorporated, concerning the coupling of automation systems, the performance of add-ons, know-how protection, the efficiency of workflows, etc. A major trend shows that in several branches WinMOD becomes integral to over-all project performance. For this purpose WinMOD provides new means for integration into the over-all data flow. Furthermore, WinMOD 7.0 runs completely on Windows 7, including all Configurations and Add-Ons. We are now glad to show you the new features in more detail in the following presentation. Yours, www.winmod.de Mewes & Partner GmbH © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 The Major Lines of Development The WinMOD System Platform Mewes & Partner Page 1 WinMOD simulates real installations and machines from the perspective of the automation system. WinMOD has the same interface to the automation system as the real installation. Thus it can reproduce the behavior of the installation in a way so that both, the simulation and the reality, show the same appearance. For this purpose, WinMOD can interface with practically all market available automation system. It has extraordinary real-time performance, is easy to handle and can be learned in short time. Real Installation © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Virtual Installation This makes WinMOD an ideal tool for: - software testing - virtual commissioning - training simulators - optimizing operation procedures - optimizing installation - education - presentation - etc. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 The Major Lines of Development Quo Vadis ? WinMOD started as a tool for testing automation systems, used by PLC programmers for efficiently testing without the real installation. The concept was adopted by operating companies for Factory Acceptance Tests (FAT), what strongly shortens commissioning. FAT, Virtual Commissioning Maintenance, Training As a result, many companies use WinMOD as an integral part of overall project performance. Hence, the usages of WinMOD are embedded into several engineering processes. Proof of Concept, Planning Continuous Software Testing © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. FAT, Virtual Commissioning, Training WinMOD provides various open interfaces, exports and imports, and fluently integrates with various real time systems. The extended usages and the interleaved usage throughout the whole project performance is now supported by functionality for planning, extensive data exchange with engineering data bases, etc. This reflects the strategic importance that WinMOD gains in over all project performance. More Simulation for Less Mouse-Clicks FAT The FATs - that test mostly IO-behaviour - were extended to complete commissioning procedures for automation systems. The resulting virtual WinMOD Installations enable complete tests of all operating sequences of the real installation. Deeper process modelling and the introduction of 3D complemented the usage for simulator training for operators and maintenance personnel. Today, WinMOD Installations can accompany the real installation throughout its further life-cycle. Software Testing Page 2 Integration into Engineering Processes A Profound role in Overall Project Performance Software Testing Mewes & Partner Maintenance, Training, Optimization Efficiency is a key qualification. For this reason functions were optimized, parameters values are proposed, default values are set according to context, etc. Workflows that were performed stepwise and manually can now be configured and executed automatically. Protection of Know-how WinMOD users provide simulation components and complete models to each other. Since these often contain considerable know-how, Components, Simulation Files and complete Projects can be protected by licenses. Windows 7 The new release of WinMOD 7.0 is running also on Windows 7. Back to the roots ? . . . WinMOD 1 was an in-house tool of Mewes & Partner, developed for internal software testing. Others were interested in using it, it was marketed, and it was successful since it was a tool from practitioners for practitioners. This basic usage is still the core and it is still simple and fast. But today's WinMOD 7.0 provides also much more . . . Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 The Major Lines of Development The WinMOD System Platform WinMOD WinMOD Workflows - Methods - Integrations WinMOD Recorder automation system in real-time WinMOD Plant WinMOD Engineering Assistance DB WinMOD-Net a WinMOD signal coupling in real-time WinMOD TCP/IP CPU CPU WinMOD Configurations WinMOD WinMOD WinMOD Basics WinMOD further . . . WinMOD System Software a) The WinMOD Configurations couple practically all market available automation systems. The real hardware can be coupled with the real bus systems, or only the software. The coupling includes all IOsignals with real-time data transfer. b) The WinMOD System Software forms the core where the simulated "WinMODPlant" is configured and run in real-time. c) The WinMOD Add-Ons add special abilities to your WinMOD System, for 3Dsimulation, for automatic engineering, for distributed simulation and more ... CPU WinMOD WinMOD-3D-View b WinMOD CPU WinMOD Page 3 The flexibility of the WinMOD System Platform enables the optimal WinMOD System for your application, tailored for your automation systems, branch and technologies, usages and engineering. e Procedures Processes Engineering Electrics Hydraulics PLCMechanics Mewes & Partner c WinMOD Add-Ons d) As WinMOD Basics, libraries and templates are provided. e) The WinMOD Workflows, Methods and Integrations embed WinMOD into the over-all engineering processes and data. d © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 The Major Lines of Development Overview on the New Features WinMOD WinMOD Workflows - Methods - Integrations automation system in real-time iv WinMOD Recorder iii WinMOD Plant ii viii WinMOD Engineering Assistance iv DB vi TCP/IP WinMOD vii v CPU i. WinMOD 7.0 released also for Windows 7 ii. Complete Operands automatically creates Operands for Components iii. Reverse EngineeringAssistance exports Simulation Models for various purposes iv. EngineeringAssistance more specific for sources and targets, integrated actions v. Content Licenses protect user know-how on level of Dongles vi. Searching and Replacing faster handling CPU WinMOD WinMOD vii. convention for internal Analog Formats WinMOD Configurations WinMOD CPU WinMOD signal coupling in real-time WinMOD iii WinMOD-Net CPU ix Page 4 Several major new features support the major lines of development: Procedures Processes Engineering Electrics Hydraulics PLCMechanics i Mewes & Partner WinMOD System Software WinMOD WinMOD-3D-View viii. Configuration A750 (S7-PLCSIM) for multiinstances further . . . ix. WinMOD Add-Ons Configuration X700 - X700_ND (PROFINET IO norm device) - X700 (PROFINET IO / PROFIsafe) x. New WinMOD OCA-Libraries for drives WinMOD WinMOD Foundations x © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. xi. New specific WinMOD Project Templates xi Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Windows 7 WinMOD 7.0 runs on Windows 7 Mewes & Partner Page 5 WinMOD 7.0 is released for • Windows 7 • Windows Server 2003 • Windows XP This concerns the complete WinMOD System Platform including • all WinMOD Configurations, • the WinMOD System Software, • all WinMOD Add-Ons. © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Complete Operands Automatic Completion of Operands for Parameters and State Variables Mewes & Partner Page 6 In addition to Automation System (AS) input and output signals, the simulated components in WinMOD often provide further signals, for example for parameterization and state indication. Operands for these additional signals can now be created automatically by means of the function Complete Operands. Automatically add Operands for Parameters and States The symbols for the Operands can be composed flexibly from several component and signal attributes. advantages: fast engineering consistent and correct naming basis for further mechanisms © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Complete Operands Connection of Simulation Levels Mewes & Partner Page 7 Corresponding components in different simulation levels are automatically connected with each other. This is achieved by the new function Complete Operands in combination with suitable naming conventions. For example: The drive of pump P1 is a bus device connected to the controller-IOs. It outputs a number-of-turns signal "P1.$>n" which is an input to the material flow simulation of P1 causing material flow "$Q_in" to "$Q_out". Bus Devices Simulation advantages: Material Flow Simulation © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. fast engineering consistent and correct naming Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Complete Operands Remove Operands Mewes & Partner Page 8 As the inverse to Complete Operands, the function Remove Operands is introduced. This new function does not delete the Operands from the project, it only removes them from the selected Components and Simulation Elements. Typical usage are: • preparing re-creating all connections • creating patterns for copying • creating templates Remove Operands advantages: fast and safe engineering © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Reverse EngineeringAssistance Modification of WinMOD Models with external Tools Mewes & Partner Page 9 WinMOD 5.0 introduced the WinMOD EngineeringAssistance which enables to automatically create WinMOD Simulations by importing Component Models from external lists to WinMOD. create Engineering Lists 1 WinMOD 7.0 now introduces the Reverse EngineeringAssistance which enables to export the Component Models from WinMOD back to the external lists. Engineering List A typical workflow consists in: EngineeringAssistance 2 Reverse EngineeringAssistance NEW ! 3 WinMOD 1) creating the Engineering Lists from installation data, e.g. the controller signal list, 2) creating the Components in WinMOD by importing them with the EngineeringAssistance, and working on them. 3) exporting the modified Components with the Reverse EngineeringAssistance and modifying them in the lists format. Re-import with step 2. advantages: export modifications made in WinMOD extended possibilities for simulation editing © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Reverse EngineeringAssistance Round-Load between WinMOD Installations and Engineering Data Bases import to Engineering Data Base Engineering Data Base export from Engineering Data Base Mewes & Partner Page 10 WinMOD contains various engineering data. Many of them are managed in engineering data bases and then imported to WinMOD for testing. Now an increasing number of customers request to modify engineering data also in WinMOD and to re-integrate the changes to the engineering data bases. As a goal it should be possible to modify the data wherever this is convenient with subsequent update of the other data base. RoundLoad This round-load is now available by combination of • EngineeringAssistance and • Reverse EngineeringAssistance. WinMOD export from WinMOD NEW ! import to WinMOD advantages: high flexibility in project performance flexible handling of continuously changing data high consistency of verified data © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Reverse EngineeringAssistance Generation of Data in WinMOD (example IO-Lists) Mewes & Partner Page 11 Several data can be created and completed with WinMOD. For example, customers increasingly request the creation of IO-lists in WinMOD. The concept consists in: list of items controller IO-list EngineeringAssistance or manually 1) creating the components with the respective item designation and type, 2) completing the operands, 1 3) exporting the resulting operands. component without IO-Operands component with IO-Operands 3 Operand Export Reverse EngineeringAssistance NEW ! 2 Complete Operands NEW ! The exported IO-list is a starting point for the symbol and configuration processing for the control system. The preliminary list can be further processed in WinMOD and analysed, e.g. by filtering. advantages: simple systematic proceeding descriptive presentation high consistency © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Reverse EngineeringAssistance Graphical Specification a b Page 12 WinMOD can be used to create clear graphical specifications of relations in installations. The graphical specification is exported with the Reverse EngineeringAssistance and then further processed. Graphical Specification of PowerSupply Power Supply Mewes & Partner NEW Reverse EngineeringAssistance c Common Simulation ! For example: a) The power supply system is graphically specified in WinMOD. b) This model is exported with the Reverse EngineeringAssistance. c) The power model is combined with the EngineeringList for the Component IOs and imported to WinMOD. d) The result is a model consisting of both, the controller-IOs and the power supply. Power Supply Engineering List from Controler IO-List d advantages: graphical editing in WinMOD easy survey high consistency © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Engineering Assistance Engineering Assistance imports from Clipboard macro type valve 17 balance 32 valve Type A V17.C_POS M1.AW 4 balance Type1 W32.R_M M1.EW 0 operand address internal Format ... Percent 0...100% . . . EE balance Type1 from clipboard from file until now Page 13 The Engineering List that specifies which components are to be created automatically was until now provided in a text file. Engineering List macro name Mewes & Partner Now it can also be provided in the clipboard. This saves steps for defining and managing the files and allows a direct supply from the source of the Engineering List to the EngineeringAssistance. The method of using a file is maintained and can be further used for more complex methods with EngineeringLists composed from different sources. NEW ! EngineeringAssistance generated files WinMOD Library advantages: faster engineering less file management © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Engineering Assistance Replace and Complete Existing Files target files target files automatic generation NEW ! automatic generation Page 14 Since the introduction of the EngineeringAssistance the variety of applications and the extend of usages grew considerably. EngineeringAssistance EngineeringAssistance Mewes & Partner While the first usages created single new files, today's usages may create a multitude of files with dedicated purposes. Therefore the need arose to direct the generated content directly into the target files. Thereby the created content of existing files is directly replaced and completed. This workflow is in many cases faster and allows to preserve file contents that is to be maintained. The replacement and completion of exiting files is option-controlled. temporary files manual copy until now advantages: faster engineering minimized file management higher flexibility © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Engineering Assistance Complete Operands after EngineeringAssistance Engineering List in clipboard macro name macro type valve 17 balance 32 valve Type A V17.C_POS M1.AW 4 balance Type1 W32.R_M M1.EW 0 operand address a internal Format ... Percent 0...100% EE balance Type1 ... Mewes & Partner Page 15 The new function Complete Operands can be called automatically after execution of the EngineeringAssistance. This enables a complete automatic generation cascade consisting of: NEW ! a) generate from clipboard from clipboard b) replace and complete existing files EngineeringAssistance c) Complete Operands Target Files NEW ! d) created Operands connect to navigation and parameterization Complete Operands b replace and complete c Completed Target Files NEW ! Automatically calling Complete Operands is option-controlled. advantages: d integrated complex workflow preventing manual faults fast engineering © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Engineering Assistance All Operand Columns Available NEW ! Mewes & Partner Page 16 While the Operand columns used by the EngineeringAssistance were initially restricted to the ones required, now all possible Operand columns can be used. This is also advantageous for the RoundLoad in connection with the Reverse EngineeringAssistance, since it allows to pass and hold more engineering data in WinMOD. Please note that also the 5 additional Operand columns can be use for the same purpose. free until now advantages: free usage of all columns more data contents available © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Content Licenses Licensing Components and Component Libraries Mewes & Partner Page 17 With the extended usages of WinMOD and with the growing simulation depth and simulation accuracy, the know-how expressed in WinMOD increases considerably. For this reasons users requested further mechanisms for know-how protection. In addition to the available methods, WinMOD 7.0 enables licensing simulation content by users on the level of WinMOD Dongles. The finest resolution for licensing is the content of WinMOD Components. This is in especially valuable for licensing WinMOD Component Libraries. licensed for reading not licensed advantages: protection of own know-how simulation file © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. usage of protected know-how of others high flexibility Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Content Licenses Licensing Simulation Files Mewes & Partner Page 18 Licensing complete Simulation Files allows to protect know-how in the content of the Simulation Files. The licensing mechanism can be flexibly combined with other protective measures, for example: • the layers can be set to invisible, then the complete content is invisible, but can be executed, • some layers are set to visible, then certain information is hidden while other information is visible. • all layers are visible, then everything can be seen, but not modified. licensed for reading not licensed advantages: protecting complete files simulation file © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. high flexibility in combinations Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Content Licenses Licensing Project Files Mewes & Partner Page 19 Licensing WinMOD Project files prevents modifying the project structure and the protects global contents. Please note that the protective levels Project, Simulation File and Component can be licensed completely independent from each other and can be freely combined. For example, the project may be licensed, but some of the simulation file are open for own adaptations. Also the Components originating from some Component Libraries may be protected, while others may be deliberately modified. licensed for reading not licensed advantages: protection of project structures simulation file © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. selective protection Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Searching and Replacing Search with Exact Match Mewes & Partner Page 20 When searching for items by test strings, the result included items whose strings included the search string. Now, the new option match entire field context enables to restrict the search results to items with strings with exact match with the search string. This feature is useful, for example, when replacing Macros of a given type. The search result for the type shows only Macros with exactly this type. NEW ! until now advantages: more selective searching faster engineering © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Searching and Replacing Replace Macro Content with automatic Macro Name Mewes & Partner Page 21 The function "Replace Macro Content" is most of the time used to replace a Macro with a new version of the same Macro Type. For this reason, the Macro Type is automatically inserted into the dialog for opening the Macro File, if the type is unique. This saves time for typing and selecting the macro type and prevents trouble arising from accidentally typing or selecting a wrong name. until now NEW ! advantages: less typing and selecting less errors faster engineering © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 Searching and Replacing Warning for Incomplete Replacing Mewes & Partner Page 22 Replacing Macros and Components is not performed, when they are in running simulation files, on non-editable layers, etc. Until today this took place without notification what may lead to a nonconsistent system and to irritation for the user. Now Replace Macro Content checks if all Macros or Components can be replaced and, if not, asks for a confirmation. NEW ! advantages: increased consistency less errors © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 internal Analog Formats Naming Convention for Internal Analog Formats Default Internal Analog Formats Mewes & Partner Page 23 In order to increase the readability of names of Internal Analog Formats, the naming convention for physical and engineering units was developed*. The names of the default Internal Analog Formats for 0 to 100 % and -100 to 100 % now follow this convention. NEW ! advantages: clear organization good readability * The naming convention for physical and engineering units can be found in the manual of the System Software. © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 internal Analog Formats Dragging-out Signal Elements with Analog Format Mewes & Partner Page 24 When Signal Elements are created by dragand-dropping from a component input or output (hold Alt-key pressed), a default format in percent was assigned to the graphical wiring. NEW ! Now, the format defined for the operand of the input or output inside of the macro is assigned also to the graphical wiring. This is in the majority of cases the natural format used for this type of signal. until now advantages: until now faster editing higher consistency less errors © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 WinMOD-SIMLINE Mewes & Partner Page 25 SIMLINE Licensed Standard Libraries Basic and Visual Elements (BASIC) • e.g. source, drain, operator, security gate, HMI-Terminal Container Conveyor Systems (CCS) • e.g. belt conveyor, accumulation conveyor, belt converter, bend conveyor Palette Conveyor Systems (PCS) • e.g. chain conveyor, turntable, palette magazine SKID Conveyor Systems (SKID) • e.g. rotary table, lifting table, turntable Storage Systems Training and Education © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. (STORE) (EDU) • e.g. shuttle, high rack , high rack feeder • SIMLINE Conveyor Elements are grouped in technology specific libraries. • In this way the SIMLINE Libraries contain different conveyor elements that are typical for a given technology. • The Libraries can be arbitrarily combined. In this way all Elements can be used together in a one layout. • All Conveyor Elements can be parameterized dynamically and can be adapted in size, position, orientation, visual nature to any type of layout. • The creation of SIMLINE Layouts with these libraries can be performed completely by any WinMOD User. • Standard Library Licenses allow to exchange SIMLINE Projects. • e.g. gantries and gripper systems, toothed belt conveyor Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 WinMOD-SIMLINE Mewes & Partner Page 26 Customer Specific SIMLINE Libraries • On demand, also specific individual SIMLINE Libraries can be build. Company A (Lib_A) SIMLINE Company License A • e.g. monorail system Company B (Lib_B) SIMLINE Company License B • e.g. gantry system specification for parameterization and for the behaviour of new customer specific SIMLINE Elements • In this case, the SIMLINE Libraries are owned exclusively by a single customer. • Customer specific libraries can be arbitrarily combined with standard libraries. • Each customer specific Library is individually licensed. • In this way SIMLINE layouts created with the library can be used only in the organization owning the license. • The creation of such libraries takes place after detailed specification of all required elements. • The libraries can be arbitrarily extended for further elements. customer specific SIMLINE Element © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 WinMOD-SIMLINE Mewes & Partner Page 27 SIMLINE Layouter 7.0 – Installation Data Base Integrated Connection Point System • Based on parameterizable SIMLINE Libraries installations for material flow can be generated from a table oriented data base. This data base is called the SIMLINE Layouter. • In the SIMLINE Layouter, conveyor elements are parameterized for size, position, orientation and sensors as given by the real installation. From these data, the SIMLINE Layout is generated. • An integrated system for connection points of the SIMLINE Library Elements enables fast and efficient creation even of large installations. • The dynamic user interface supports selection and parameterization of elements. Generated SIMLINE Layout © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 WinMOD-SIMLINE Mewes & Partner Page 28 SIMLINE Generator 7.0 with Integrated Rule System • The new SIMLINE Generator 7.0 extensively supports rule based parameterization of the WinMOD to SIMLINE signal coupling. • By combination of rule systems and filters for components, signals and sensor object in SIMLINE, and automatic "fine tuning" is enabled even for complex installations. • The rule systems can be edited by integrated functions directly in the generator. • This includes, for example, rule systems like WinMOD Interface Converter for signal adaptation, WinMOD Parameter Description for sensor orientation or WinMOD Hint Filter for 3D-Object identification. Integrated System of Rules, for e.g. orientation of sensors © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 WinMOD Configurations WinMOD Configuration A750 (SIMATIC S7 PLCSIM 120) Virtual PLC for complete virtual test- and training simulators for SIMATIC S7 Systems Mewes & Partner Page 29 For SIMATIC S7/ PCS7 Simulation PLCSIM For SIMATIC PLCSIM version V5.4-SP3, PLCSIM has multi-instance ability. The WinMOD Configuration A750 supports now an additional direct access to the periphery address areas, flags, data blocks and the multi-instance ability from PLCSIM. WinMOD Configuration A750 ST (standard) WinMOD coupling to a PLCSIM-instance with: read/write modus of the with PLCSIM simulated -S7-I/O-memory areas -S7-I/O-periphery areas (new) -S7-flags (new) -S7-data blocks (new) WinMOD Configuration A750 XT (extended) (new) WinMOD coupling to PLCSIM-multi-instances (currently up to 8) with: read/write modus of the with PLCSIM simulated - S7-I/O-memory areas - S7-I/O-periphery areas (new) - S7-flags (new) - S7-data blocks (new) Advantages: With the system coupling between WinMOD and SIMATIC S7 Simulation PLCSIM it is possible to realize cost-efficient test- and training simulations. © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt WinMOD System Platform Version 7.0 WinMOD Configurations Mewes & Partner Page 30 For all Automation Systems (AS) with PROFINET IO-Master With WinMOD Configuration X700 any PROFINET IOparticipant can be simulated (emulated) and can be connected to any automation system (AS) with PROFINET IO-controller. The PROFINET devices that are to be simulated are configured in the WinMOD PROFINET Configurator manually or automatically online. For any AS-Controller mit PROFINET IO PCI PROFINET IO Ethernet standard interface simulated PROFINET IO devices PLC – hardware configuration with different Profinet IO-Devices For selected automation systems, additional functions for workflow optimisation of signal list import and export can be developed and provided. one Variant (AS-neutral, licensable): - cyclic IO device emulation (up to 254) Usage: Support for development and test of single AS program functions and complete AS programs, independent from a correctly planned IO-periphery. No special is hardware required. The PROFINET-Emulation is executed by an especially developed Windows kernel application. The Ethernet network hardware has to be approved by Mewes & Partner. Typically a standard Ethernet network card can be used. © Copyright Mewes & Partner GmbH Alle Rechte vorbehalten. All rights reserved. Mewes & Partner GmbH 2011_CW WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
© Copyright 2024