What is new in WinMOD 7.0 ? WinMOD System Software 7.0

WinMOD System
WinMOD
Platform
System
Version
Software
7.0 7.0
Mewes & Partner
Page 0
Real-time Simulation Center for Automation
What is new in WinMOD 7.0 ?
Dear Customer,
we are pleased to present to you the latest version of
our real-time simulation and software testing platform
WinMOD 7.0.
In recent years, much functionality of WinMOD proved
stable, versatile and in fact ahead of its time. Even so,
several new developments were incorporated,
concerning the coupling of automation systems, the
performance of add-ons, know-how protection, the
efficiency of workflows, etc.
A major trend shows that in several branches WinMOD
becomes integral to over-all project performance. For
this purpose WinMOD provides new means for
integration into the over-all data flow.
Furthermore, WinMOD 7.0 runs completely on
Windows 7, including all Configurations and Add-Ons.
We are now glad to show you the new features in more
detail in the following presentation.
Yours,
www.winmod.de
Mewes & Partner GmbH
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
The Major Lines of Development
The WinMOD System Platform
Mewes & Partner
Page 1
WinMOD simulates real installations and
machines from the perspective of the
automation system.
WinMOD has the same interface to the
automation system as the real installation.
Thus it can reproduce the behavior of the
installation in a way so that both, the
simulation and the reality, show the same
appearance.
For this purpose, WinMOD can interface with
practically all market available automation
system. It has extraordinary real-time
performance, is easy to handle and can be
learned in short time.
Real
Installation
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Virtual
Installation
This makes WinMOD an ideal tool for:
- software testing
- virtual commissioning
- training simulators
- optimizing operation procedures
- optimizing installation
- education
- presentation
- etc.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
The Major Lines of Development
Quo Vadis
?
WinMOD started as a tool for testing automation systems, used by
PLC programmers for efficiently testing without the real installation.
The concept was adopted by operating companies for Factory
Acceptance Tests (FAT), what strongly shortens commissioning.
FAT, Virtual
Commissioning
Maintenance,
Training
As a result, many companies use WinMOD as an integral part of
overall project performance. Hence, the usages of WinMOD are
embedded into several engineering processes.
Proof of
Concept,
Planning
Continuous
Software
Testing
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
FAT, Virtual
Commissioning,
Training
WinMOD provides various open interfaces, exports and imports, and
fluently integrates with various real time systems. The extended
usages and the interleaved usage throughout the whole project
performance is now supported by functionality for planning, extensive
data exchange with engineering data bases, etc. This reflects the
strategic importance that WinMOD gains in over all project
performance.
More Simulation for Less Mouse-Clicks
FAT
The FATs - that test mostly IO-behaviour - were extended to complete
commissioning procedures for automation systems. The resulting
virtual WinMOD Installations enable complete tests of all operating
sequences of the real installation. Deeper process modelling and the
introduction of 3D complemented the usage for simulator training for
operators and maintenance personnel. Today, WinMOD Installations
can accompany the real installation throughout its further life-cycle.
Software
Testing
Page 2
Integration into Engineering Processes
A Profound role in Overall Project Performance
Software
Testing
Mewes & Partner
Maintenance,
Training,
Optimization
Efficiency is a key qualification. For this reason functions were
optimized, parameters values are proposed, default values are set
according to context, etc. Workflows that were performed stepwise
and manually can now be configured and executed automatically.
Protection of Know-how
WinMOD users provide simulation components and complete models
to each other. Since these often contain considerable know-how,
Components, Simulation Files and complete Projects can be protected
by licenses.
Windows 7
The new release of WinMOD 7.0 is running also on Windows 7.
Back to the roots ?
. . . WinMOD 1 was an in-house tool of Mewes & Partner, developed
for internal software testing. Others were interested in using it, it was
marketed, and it was successful since it was a tool from practitioners
for practitioners. This basic usage is still the core and it is still simple
and fast. But today's WinMOD 7.0 provides also much more . . .
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
The Major Lines of Development
The WinMOD System Platform
WinMOD
WinMOD Workflows - Methods - Integrations
WinMOD Recorder
automation system
in real-time
WinMOD Plant
WinMOD Engineering
Assistance
DB
WinMOD-Net
a
WinMOD
signal coupling
in real-time
WinMOD
TCP/IP
CPU
CPU
WinMOD Configurations
WinMOD
WinMOD
WinMOD Basics
WinMOD
further . . .
WinMOD System Software
a) The WinMOD Configurations couple
practically all market available automation
systems. The real hardware can be
coupled with the real bus systems, or only
the software. The coupling includes all IOsignals with real-time data transfer.
b) The WinMOD System Software forms the
core where the simulated "WinMODPlant" is configured and run in real-time.
c) The WinMOD Add-Ons add special
abilities to your WinMOD System, for 3Dsimulation, for automatic engineering,
for distributed simulation and more ...
CPU
WinMOD
WinMOD-3D-View
b
WinMOD
CPU
WinMOD
Page 3
The flexibility of the WinMOD System
Platform enables the optimal WinMOD
System for your application, tailored for
your automation systems, branch and
technologies, usages and engineering.
e
Procedures
Processes
Engineering
Electrics
Hydraulics
PLCMechanics
Mewes & Partner
c
WinMOD Add-Ons
d) As WinMOD Basics, libraries and
templates are provided.
e) The WinMOD Workflows, Methods and
Integrations embed WinMOD into the
over-all engineering processes and data.
d
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
The Major Lines of Development
Overview on the New Features
WinMOD
WinMOD Workflows - Methods - Integrations
automation system
in real-time
iv
WinMOD Recorder
iii
WinMOD Plant
ii
viii
WinMOD Engineering
Assistance
iv DB
vi
TCP/IP
WinMOD
vii
v
CPU
i.
WinMOD 7.0 released also for Windows 7
ii.
Complete Operands automatically
creates Operands for Components
iii.
Reverse EngineeringAssistance exports
Simulation Models for various purposes
iv.
EngineeringAssistance more specific for
sources and targets, integrated actions
v.
Content Licenses protect user know-how
on level of Dongles
vi.
Searching and Replacing faster handling
CPU
WinMOD
WinMOD
vii. convention for internal Analog Formats
WinMOD Configurations
WinMOD
CPU
WinMOD
signal coupling
in real-time
WinMOD
iii
WinMOD-Net
CPU
ix
Page 4
Several major new features support the
major lines of development:
Procedures
Processes
Engineering
Electrics
Hydraulics
PLCMechanics
i
Mewes & Partner
WinMOD System Software
WinMOD
WinMOD-3D-View
viii. Configuration A750 (S7-PLCSIM) for multiinstances
further . . .
ix.
WinMOD Add-Ons
Configuration X700
- X700_ND (PROFINET IO norm device)
- X700 (PROFINET IO / PROFIsafe)
x. New WinMOD OCA-Libraries for drives
WinMOD
WinMOD Foundations
x
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
xi. New specific WinMOD Project Templates
xi
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Windows 7
WinMOD 7.0 runs on Windows 7
Mewes & Partner
Page 5
WinMOD 7.0 is released for
• Windows 7
• Windows Server 2003
• Windows XP
This concerns the complete WinMOD System
Platform including
• all WinMOD Configurations,
• the WinMOD System Software,
• all WinMOD Add-Ons.
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Complete Operands
Automatic Completion of Operands for
Parameters and State Variables
Mewes & Partner
Page 6
In addition to Automation System (AS) input
and output signals, the simulated
components in WinMOD often provide
further signals, for example for
parameterization and state indication.
Operands for these additional signals can
now be created automatically by means of
the function Complete Operands.
Automatically
add Operands for
Parameters and States
The symbols for the Operands can be
composed flexibly from several component
and signal attributes.
advantages:
fast engineering
consistent and correct naming
basis for further mechanisms
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Complete Operands
Connection of Simulation Levels
Mewes & Partner
Page 7
Corresponding components in different
simulation levels are automatically
connected with each other.
This is achieved by the new function
Complete Operands in combination with
suitable naming conventions.
For example: The drive of pump P1 is a bus
device connected to the controller-IOs. It
outputs a number-of-turns signal "P1.$>n"
which is an input to the material flow
simulation of P1 causing material flow
"$Q_in" to "$Q_out".
Bus Devices
Simulation
advantages:
Material Flow
Simulation
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
fast engineering
consistent and correct naming
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Complete Operands
Remove Operands
Mewes & Partner
Page 8
As the inverse to Complete Operands, the
function Remove Operands is introduced.
This new function does not delete the
Operands from the project, it only removes
them from the selected Components and
Simulation Elements.
Typical usage are:
• preparing re-creating all connections
• creating patterns for copying
• creating templates
Remove
Operands
advantages:
fast and safe engineering
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Reverse EngineeringAssistance
Modification of WinMOD Models
with external Tools
Mewes & Partner
Page 9
WinMOD 5.0 introduced the
WinMOD EngineeringAssistance which
enables to automatically create WinMOD
Simulations by importing Component
Models from external lists to WinMOD.
create Engineering Lists
1
WinMOD 7.0 now introduces the
Reverse EngineeringAssistance which
enables to export the Component Models
from WinMOD back to the external lists.
Engineering List
A typical workflow consists in:
EngineeringAssistance
2
Reverse
EngineeringAssistance
NEW !
3
WinMOD
1) creating the Engineering Lists from
installation data, e.g. the controller signal list,
2) creating the Components in WinMOD by
importing them with the EngineeringAssistance, and working on them.
3) exporting the modified Components with
the Reverse EngineeringAssistance and
modifying them in the lists format.
Re-import with step 2.
advantages:
export modifications made in WinMOD
extended possibilities for simulation editing
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Reverse EngineeringAssistance
Round-Load between WinMOD Installations and
Engineering Data Bases
import
to Engineering Data Base
Engineering
Data Base
export
from Engineering Data Base
Mewes & Partner
Page 10
WinMOD contains various engineering data.
Many of them are managed in engineering
data bases and then imported to WinMOD
for testing.
Now an increasing number of customers
request to modify engineering data also in
WinMOD and to re-integrate the changes to
the engineering data bases.
As a goal it should be possible to modify the
data wherever this is convenient with
subsequent update of the other data base.
RoundLoad
This round-load is now available by
combination of
• EngineeringAssistance and
• Reverse EngineeringAssistance.
WinMOD
export
from WinMOD
NEW !
import
to WinMOD
advantages:
high flexibility in project performance
flexible handling of continuously changing
data
high consistency of verified data
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Reverse EngineeringAssistance
Generation of Data in WinMOD
(example IO-Lists)
Mewes & Partner
Page 11
Several data can be created and completed
with WinMOD.
For example, customers increasingly request
the creation of IO-lists in WinMOD.
The concept consists in:
list of items
controller IO-list
EngineeringAssistance
or manually
1) creating the components with the
respective item designation and type,
2) completing the operands,
1
3) exporting the resulting operands.
component
without IO-Operands
component
with IO-Operands
3
Operand Export
Reverse
EngineeringAssistance
NEW !
2
Complete Operands
NEW !
The exported IO-list is a starting point for
the symbol and configuration processing for
the control system.
The preliminary list can be further
processed in WinMOD and analysed, e.g.
by filtering.
advantages:
simple systematic proceeding
descriptive presentation
high consistency
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Reverse EngineeringAssistance
Graphical Specification
a
b
Page 12
WinMOD can be used to create clear
graphical specifications of relations in
installations. The graphical specification is
exported with the Reverse EngineeringAssistance and then further processed.
Graphical Specification of PowerSupply
Power Supply
Mewes & Partner
NEW
Reverse
EngineeringAssistance
c
Common Simulation
!
For example:
a) The power supply system is graphically
specified in WinMOD.
b) This model is exported with the Reverse
EngineeringAssistance.
c) The power model is combined with the
EngineeringList for the Component IOs
and imported to WinMOD.
d) The result is a model consisting of both,
the controller-IOs and the power supply.
Power Supply
Engineering List
from Controler IO-List
d
advantages:
graphical editing in WinMOD
easy survey
high consistency
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Engineering Assistance
Engineering Assistance imports from Clipboard
macro type
valve 17
balance 32
valve Type A V17.C_POS M1.AW 4
balance Type1 W32.R_M M1.EW 0
operand
address
internal Format
...
Percent 0...100% . . .
EE balance Type1
from clipboard
from file
until now
Page 13
The Engineering List that specifies which
components are to be created automatically
was until now provided in a text file.
Engineering List
macro name
Mewes & Partner
Now it can also be provided in the
clipboard. This saves steps for defining and
managing the files and allows a direct
supply from the source of the Engineering
List to the EngineeringAssistance.
The method of using a file is maintained
and can be further used for more complex
methods with EngineeringLists composed
from different sources.
NEW !
EngineeringAssistance
generated files
WinMOD Library
advantages:
faster engineering
less file management
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Engineering Assistance
Replace and Complete Existing Files
target files
target files
automatic
generation
NEW !
automatic
generation
Page 14
Since the introduction of the
EngineeringAssistance the variety of
applications and the extend of usages
grew considerably.
EngineeringAssistance
EngineeringAssistance
Mewes & Partner
While the first usages created single new
files, today's usages may create a multitude
of files with dedicated purposes.
Therefore the need arose to direct the
generated content directly into the target
files. Thereby the created content of existing
files is directly replaced and completed.
This workflow is in many cases faster and
allows to preserve file contents that is to be
maintained.
The replacement and completion of exiting
files is option-controlled.
temporary
files
manual
copy
until now
advantages:
faster engineering
minimized file management
higher flexibility
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Engineering Assistance
Complete Operands after EngineeringAssistance
Engineering List in clipboard
macro name
macro type
valve 17
balance 32
valve Type A
V17.C_POS M1.AW 4
balance Type1 W32.R_M
M1.EW 0
operand
address
a
internal Format
...
Percent 0...100%
EE balance Type1
...
Mewes & Partner
Page 15
The new function Complete Operands can
be called automatically after execution of
the EngineeringAssistance.
This enables a complete automatic
generation cascade consisting of:
NEW !
a) generate from clipboard
from clipboard
b) replace and complete existing files
EngineeringAssistance
c) Complete Operands
Target Files
NEW !
d) created Operands connect to navigation
and parameterization
Complete Operands
b
replace
and complete
c
Completed
Target Files
NEW !
Automatically calling Complete Operands is
option-controlled.
advantages:
d
integrated complex workflow
preventing manual faults
fast engineering
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Engineering Assistance
All Operand Columns Available
NEW !
Mewes & Partner
Page 16
While the Operand columns used by the
EngineeringAssistance were initially
restricted to the ones required, now all
possible Operand columns can be used.
This is also advantageous for the RoundLoad in connection with the Reverse
EngineeringAssistance, since it allows to
pass and hold more engineering data in
WinMOD.
Please note that also the 5 additional
Operand columns can be use for the same
purpose.
free until now
advantages:
free usage of all columns
more data contents available
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Content Licenses
Licensing Components and Component Libraries
Mewes & Partner
Page 17
With the extended usages of WinMOD and
with the growing simulation depth and
simulation accuracy, the know-how
expressed in WinMOD increases
considerably.
For this reasons users requested further
mechanisms for know-how protection.
In addition to the available methods,
WinMOD 7.0 enables licensing simulation
content by users on the level of WinMOD
Dongles.
The finest resolution for licensing is the
content of WinMOD Components. This is in
especially valuable for licensing WinMOD
Component Libraries.
licensed
for reading
not licensed
advantages:
protection of own know-how
simulation file
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
usage of protected know-how of others
high flexibility
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Content Licenses
Licensing Simulation Files
Mewes & Partner
Page 18
Licensing complete Simulation Files
allows to protect know-how in the content of
the Simulation Files.
The licensing mechanism can be flexibly
combined with other protective measures,
for example:
• the layers can be set to invisible, then the
complete content is invisible, but can be
executed,
• some layers are set to visible, then certain
information is hidden while other
information is visible.
• all layers are visible, then everything can
be seen, but not modified.
licensed
for reading
not licensed
advantages:
protecting complete files
simulation file
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
high flexibility in combinations
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Content Licenses
Licensing Project Files
Mewes & Partner
Page 19
Licensing WinMOD Project files prevents
modifying the project structure and the
protects global contents.
Please note that the protective levels
Project, Simulation File and Component can
be licensed completely independent from
each other and can be freely combined.
For example, the project may be licensed, but
some of the simulation file are open for own
adaptations. Also the Components originating
from some Component Libraries may be
protected, while others may be deliberately
modified.
licensed
for reading
not licensed
advantages:
protection of project structures
simulation file
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
selective protection
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Searching and Replacing
Search with Exact Match
Mewes & Partner
Page 20
When searching for items by test strings, the
result included items whose strings included
the search string.
Now, the new option match entire field
context enables to restrict the search
results to items with strings with exact
match with the search string.
This feature is useful, for example, when
replacing Macros of a given type. The
search result for the type shows only Macros
with exactly this type.
NEW !
until now
advantages:
more selective searching
faster engineering
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Searching and Replacing
Replace Macro Content with
automatic Macro Name
Mewes & Partner
Page 21
The function "Replace Macro Content" is
most of the time used to replace a Macro
with a new version of the same Macro
Type.
For this reason, the Macro Type is
automatically inserted into the dialog for
opening the Macro File, if the type is unique.
This saves time for typing and selecting the
macro type and prevents trouble arising
from accidentally typing or selecting a wrong
name.
until now
NEW !
advantages:
less typing and selecting
less errors
faster engineering
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
Searching and Replacing
Warning for Incomplete Replacing
Mewes & Partner
Page 22
Replacing Macros and Components is not
performed, when they are in running
simulation files, on non-editable layers, etc.
Until today this took place without
notification what may lead to a nonconsistent system and to irritation for the
user.
Now Replace Macro Content checks if all
Macros or Components can be replaced and,
if not, asks for a confirmation.
NEW !
advantages:
increased consistency
less errors
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
internal Analog Formats
Naming Convention for Internal Analog Formats
Default Internal Analog Formats
Mewes & Partner
Page 23
In order to increase the readability of names
of Internal Analog Formats, the naming
convention for physical and engineering
units was developed*.
The names of the default Internal Analog
Formats for 0 to 100 % and -100 to 100 %
now follow this convention.
NEW !
advantages:
clear organization
good readability
* The naming convention for physical and engineering units
can be found in the manual of the System Software.
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
internal Analog Formats
Dragging-out Signal Elements with Analog Format
Mewes & Partner
Page 24
When Signal Elements are created by dragand-dropping from a component input or
output (hold Alt-key pressed), a default
format in percent was assigned to the
graphical wiring.
NEW !
Now, the format defined for the operand of
the input or output inside of the macro is
assigned also to the graphical wiring.
This is in the majority of cases the natural
format used for this type of signal.
until now
advantages:
until now
faster editing
higher consistency
less errors
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
WinMOD-SIMLINE
Mewes & Partner
Page 25
SIMLINE Licensed Standard Libraries
Basic and Visual Elements (BASIC)
• e.g. source, drain, operator,
security gate, HMI-Terminal
Container Conveyor Systems (CCS)
• e.g. belt conveyor, accumulation
conveyor, belt converter, bend
conveyor
Palette Conveyor Systems
(PCS)
• e.g. chain conveyor, turntable,
palette magazine
SKID Conveyor Systems
(SKID)
• e.g. rotary table, lifting table,
turntable
Storage Systems
Training and Education
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
(STORE)
(EDU)
• e.g. shuttle, high rack , high rack
feeder
• SIMLINE Conveyor Elements are grouped
in technology specific libraries.
• In this way the SIMLINE Libraries contain
different conveyor elements that are
typical for a given technology.
• The Libraries can be arbitrarily combined.
In this way all Elements can be used
together in a one layout.
• All Conveyor Elements can be
parameterized dynamically and can be
adapted in size, position, orientation, visual
nature to any type of layout.
• The creation of SIMLINE Layouts with
these libraries can be performed completely
by any WinMOD User.
• Standard Library Licenses allow to
exchange SIMLINE Projects.
• e.g. gantries and gripper systems,
toothed belt conveyor
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
WinMOD-SIMLINE
Mewes & Partner
Page 26
Customer Specific SIMLINE Libraries
• On demand, also specific individual
SIMLINE Libraries can be build.
Company A (Lib_A)
SIMLINE Company License A
• e.g. monorail system
Company B (Lib_B)
SIMLINE Company License B
• e.g. gantry system
specification for parameterization and for the behaviour
of new customer specific SIMLINE Elements
• In this case, the SIMLINE Libraries are
owned exclusively by a single customer.
• Customer specific libraries can be
arbitrarily combined with standard
libraries.
• Each customer specific Library is
individually licensed.
• In this way SIMLINE layouts created with
the library can be used only in the
organization owning the license.
• The creation of such libraries takes place
after detailed specification of all required
elements.
• The libraries can be arbitrarily extended
for further elements.
customer specific
SIMLINE Element
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
WinMOD-SIMLINE
Mewes & Partner
Page 27
SIMLINE Layouter 7.0 – Installation Data Base
Integrated
Connection Point System
• Based on parameterizable SIMLINE
Libraries installations for material flow can
be generated from a table oriented data
base. This data base is called the
SIMLINE Layouter.
• In the SIMLINE Layouter, conveyor
elements are parameterized for size,
position, orientation and sensors as given
by the real installation. From these data,
the SIMLINE Layout is generated.
• An integrated system for connection
points of the SIMLINE Library Elements
enables fast and efficient creation even of
large installations.
• The dynamic user interface supports
selection and parameterization of
elements.
Generated SIMLINE Layout
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
WinMOD-SIMLINE
Mewes & Partner
Page 28
SIMLINE Generator 7.0 with Integrated Rule System
• The new SIMLINE Generator 7.0
extensively supports rule based
parameterization of the WinMOD to
SIMLINE signal coupling.
• By combination of rule systems and
filters for components, signals and sensor
object in SIMLINE, and automatic "fine
tuning" is enabled even for complex
installations.
• The rule systems can be edited by
integrated functions directly in the
generator.
• This includes, for example, rule systems
like WinMOD Interface Converter for
signal adaptation, WinMOD Parameter
Description for sensor orientation or
WinMOD Hint Filter for 3D-Object
identification.
Integrated System of Rules,
for e.g. orientation of sensors
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
WinMOD Configurations
WinMOD Configuration A750 (SIMATIC S7 PLCSIM 120)
Virtual PLC for complete virtual test- and training simulators for SIMATIC S7 Systems
Mewes & Partner
Page 29
For SIMATIC S7/ PCS7 Simulation PLCSIM
For SIMATIC PLCSIM version V5.4-SP3, PLCSIM has
multi-instance ability. The WinMOD Configuration
A750 supports now an additional direct access to the
periphery address areas, flags, data blocks and the
multi-instance ability from PLCSIM.
WinMOD Configuration A750 ST (standard)
WinMOD coupling to a PLCSIM-instance with:
read/write modus of the with PLCSIM simulated
-S7-I/O-memory areas
-S7-I/O-periphery areas (new)
-S7-flags (new)
-S7-data blocks (new)
WinMOD Configuration A750 XT (extended) (new)
WinMOD coupling to PLCSIM-multi-instances
(currently up to 8) with:
read/write modus of the with PLCSIM simulated
- S7-I/O-memory areas
- S7-I/O-periphery areas (new)
- S7-flags (new)
- S7-data blocks (new)
Advantages:
With the system coupling between WinMOD and
SIMATIC S7 Simulation PLCSIM it is possible to
realize cost-efficient test- and training simulations.
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt
WinMOD System Platform Version 7.0
WinMOD Configurations
Mewes & Partner
Page 30
For all Automation Systems (AS)
with PROFINET IO-Master
With WinMOD Configuration X700 any PROFINET IOparticipant can be simulated (emulated) and can be
connected to any automation system (AS) with
PROFINET IO-controller.
The PROFINET devices that are to be simulated are
configured in the WinMOD PROFINET Configurator
manually or automatically online.
For any AS-Controller mit PROFINET IO
PCI
PROFINET IO
Ethernet standard interface
simulated PROFINET IO devices
PLC – hardware configuration
with different Profinet IO-Devices
For selected automation systems, additional functions
for workflow optimisation of signal list import and
export can be developed and provided.
one Variant (AS-neutral, licensable):
- cyclic IO device emulation (up to 254)
Usage:
Support for development and test of single AS
program functions and complete AS programs,
independent from a correctly planned IO-periphery.
No special is hardware required.
The PROFINET-Emulation is executed by an
especially developed Windows kernel application. The
Ethernet network hardware has to be approved by
Mewes & Partner. Typically a standard Ethernet
network card can be used.
© Copyright Mewes & Partner GmbH
Alle Rechte vorbehalten. All rights reserved.
Mewes & Partner GmbH 2011_CW
WinMOD-Präsentationen\WinMOD_System\Systemsoftware\New_in_WinMOD_7.0_en.ppt