P R O D U C T I N F O R M AT I O N FLOWSIC 200 Measuring Flow speed A real titan – outstanding amongst longterm tunnel monitoring devices. In over 200 tunnels worldwide. Why choose the FLOWSIC 200? Minimizing your operating expenses by service intervals of up to 5 years1 ■ Capable of covering very long measured section of up to 40 meters ■ Made from extremely rugged hardware – titan, stainless steel and die cast ■ Transmitter receiver unit Terminal box Advanced Ultrasonic Technology Evaluation unit v1 FLOWSIC2 00 v3 v4 Terminal box 1 Bus compatible 2 wire cabling (RS 485) PROFIBUS v2 Analog, digital inputs/outputs • High-accuracy measurement at each point across the tunnel • High precision of air flow even at very low velocity rates • Additional recording of wind directions • Stand-alone measuring system without any moving parts • Simple Installation and easy to use controls for FLSE 200-H only Analyzers and Process Instrumentation 8 007 537/06-2005/BW • Printed in Germany (07-2005) • Subject to change without prior notice Selection of transceiver units Evaluation Unit FLSE 200-M, Aluminium Cast Housing c c FLSE 200-H, stainl. steel housing (titan transducer) FLSE 200-M SS; stainless steel housing Ultrasonic Measurement Principle Technical Data FLOWSIC 200 Ultrasonic transducers which act alternately as transmitter and receiver are installed on either side of the tunnel at an angle of 45° to 60° to the tunnel axis. The transit time of each sonic pulse depends on wind speed and direction, with the transit time being shorter at forward and longer at reverse direction. From the difference in transit time air velocity can be calculated irrespective of pressure and temperature conditions. Measurement value processing safeguards high accuracy and noise resistance for the measured values of the FLOWSIC 200. Type of models: Transceiver unit • FLSE 200-M, Aluminium cast housing (alumin. transducer) • FLSE 200-M SS, Stainl. Steel housing (alumin. transducer) • FLSE 200-H, Stainless Steel housing (titanium transducer) Evaluation Unit Measuring value processing/output, monitor function; cable length to TR unit: 500 m max. (with optional data repeater 1000 m max.); larger distances on request Commisioning and Maintenance Parameters are set with the help of our easy to use MEPAFLOW 200, a window compatible software program. The evaluation unit and the computer are connected via a RS 232 interface. The setting of parameters, regarding i.e. measuring distance, range and response time are, thanks to MEPAFLOW 200 a simple task. A manual zero-point adjustment is no longer necessary as this is carried out automatically by the measurement device. During every day running operation MEPAFLOW offers an extensive diagnosis routine. Maintenance of the FLOWSIC 200 consits of cleaning the transceiver unit. The maintenance intervals of ½ to 1 year up to 5 years are based on individual installation conditions and the device model used. Measurement Data Measur. component Velocity of air flows Measuring Principle Measurement of difference in ultrasonic transit time Measuring range –20 m/s (65 ft/sec) ... + 20 m/s (65 ft/sec); cont. variable Accuracy ± 0.1 m/s (0.3 ft/sec); depending on calibration, installation, flow profile, temp. and measuring distance Measuring distance 5 … 25 m (16 … 82 ft) with FLSE 200-M and -M SS 5 … 40 m (16 … 130 ft) with FLSE-H; larger on request Response time 1 … 300 s (sec); freely selectable Ambient Conditions Ambient temperature –20…+50 °C (–4 … 120 °F) Device Data Maintenance intervals ½… 1 year: FLSE 200-M 1 … 5 years: FLSE 200-H depend. on application cond. Point of Installation • Height above road • Angle to tunnel axis 4.2 m (14 ft) typical 45° … 60° Displays • Measuring values • Status LC-Display with 2 rows LEDs (operation, faults, maintenance, cycles) Power supply 90 … 140/190 … 260 V AC; 50/60 Hz; power consumption: approx. 20 W max. Dimensions (L x W x D) FLSE 200-M: 80 x 80 x 120 mm3 (260 x 260 x 393 ft3) FLSE 200-M SS/H: 80 x 150 x 150 mm3 (260 x 492 x 492 ft3) FLA 200: 240 x 200 x 120 mm3 (787 x 565 x 394 ft3) Weight FLSE 200-M: approx. 1 kg (2.2 lb) FLSE 200-M SS/H:approx. 2 kg (4.4 lb) FLA 200: approx. 1.5 kg (3.3 lb) Protection class IP 65/NEMA 4X Connection/Interface via evaluation unit (customer-provided) Signals 1 analog output: 0…20 mA, 750 Ω max. load optional: max. 2 additional analog modules (inputs/outputs) 4 relays: 48 V AC, 1 A; electrically isolated Interface RS 232 for service purposes; optional: PROFIBUS, RS 422 for data transfer SICK MAIHAK GmbH | Analyzers and Process Instrumentation Nimburger Str. 11 | 79276 Reute | Germany | www.sick-maihak.com Fon +49 7641 4 69-0 | Fax 0 76 41 4 69-11 49 | info.sick-maihak@sick.de Analyzers and Process Instrumentation
© Copyright 2025