ADDENDUM #1

PUBLIC WORKS & GOVERNMENT SERVICES CANADA
Pacific Region - Professional and Technical Services
Project ¹ R.056206.001
ADDENDUM #1
Agassiz, B. C - Kent Institution Housing Unit/Segregation
INSTALL DRUG LOO
2012-12-19
Page 1
The following changes in the tender documents are effective immediately. This addendum will form part of the
contract documents.
SPECIFICATIONS
.1
01 01 50 - GENERAL INSTRUCTIONS
Paragraph 10.1:
(1)
Delete : first sentence and Add new sentence:
Construction of a Dust Barrier System to CAN/CSA-Z317.13-07 - Infection Control During
Construction, Renovation, and Maintenance of Health Care Facilities will form the basis of the
IP&C/Dust Control Plan.
Paragraph 10.3:
(2)
.2
Revise: words “Drug Loo Room” to read: Work area.
05 50 00 - METAL FABRICATIONS
Clause 3.2:
(3)
(4)
Delete: paragraphs .1, .2 & .3.
Add: new paragraphs .1, .2, .3 & .4:
.1
Install steel plate infill panels to fit existing glazed openings and resized pressed steel
frames. Secure plates to frames by using steel angle glazing beads or by stitch welds.
Fill spaces between stitch welds and grind smooth.
.2
Weld 3 mm thickness pressed steel frame to accommodate sliding door rough opening.
.3
Install 4.8 mm steel plate frames at masonry opening and at new pressed steel frame at
new sliding door opening. Provide expansion stud type anchors to fasten plate to masonry
wall at 1/3rd points in two staggered rows. Use anchors with flush counter sunk heads. Stitch
weld plate to new jamb frame noted in previous paragraph, (at existing glazed opening previously
removed) .
.4
Provide steel plates fastened to masonry walls and welded to steel frames to provide a
plumb level surface for sliding door trackset, locking columns and track guide.
DRAWINGS
.1
New Drawings:
(5)
Add: the following new drawings and product data attached to this addendum:
.1
RA1 - Door 1. (1 page)
.2
Detention Hollow Metal Door Shop Drawings. (5 pages)
.3
7205 Trackset Plan Views and Elevations (15 pages)
Project ¹ R.056206.001
PUBLIC WORKS & GOVERNMENT SERVICES CANADA
Pacific Region - Professional and Technical Services
ADDENDUM #1
Agassiz, B. C - Kent Institution Housing Unit/Segregation
INSTALL DRUG LOO
.2
2012-12-19
Page 2
Drawing A1 - Key Plan, Existing Partial Floor Plan, Renovated Partial Floor Plan
Renovated Partial Floor Plan
(6)
Clarification: existing concrete floor thickness is 110 mm thickness.
(7)
Add: “Replace removed carpeted floor finish with new 28 oz level loop BCF type 66 nylon carpet
with synthetic backing, glued to concrete floor. Provide new rubber base to match existing colour
and size.” Replace carpeting for entire room adjacent to room 126a & 127
(8)
Clarification: new drawings issued to supplement installation of new sliding door, trackset,
locking columns and track guide. Drawings issued in this addendum supercedes tender drawing
A1 in regards to installation of new sliding door assembly.
END OF ADDENDUM No 1
INDUSTRIES INC.
DOOR AND FRAME DIVISION
Detention Hollow Metal Door
Shop Drawings
Project:
DRUG LOO SLIDING DOOR
Location: UNIT J + K - KENT INSTITUTION
Prepared By:
Contractor: PETRA DETENTION GROUP
Date:
mcsteeves
11/5/2012
Revision Date:
12/19/12
GENERAL NOTES:
PLEASE READ
1) FABRICATION OF HOLLOW METAL DOORS & FRAMES WILL NOT
COMMENCE UNTIL THE FOLLOWING IS RECEIVED:
A) APPROVED SHOP DRAWINGS
B) APPROVED HARDWARE SCHEDULE
C) ALL NECESSARY HARDWARE TEMPLATES
NOTE: LEADTIMES VARY SO THIS INFORMATION IS CRITICAL
11) ALL HOLLOW METAL DOORS WILL BE UNDERCUT AS PER
THE FOLLOWING DRAWINGS.
UNLESS ADVISED OTHERWISE (NOTE UNDERCUT IS FROM
BOTTOM OF THE FRAME TO THE BOTTOM OF THE DOOR).
2) THESE DRAWINGS ARE FOR APEX USE ONLY. APEX WILL NOT
ACCEPT ANY RESPONSIBILITY DUE TO ERRORS CAUSED BY
THE USE OF THESE DRAWINGS BY OTHER TRADES.
13) ALL MATERIAL TO BE CHECKED BY GENERAL CONTRACTOR
PRIOR TO INSTALLATION. NOTIFY APEX IF MATERIAL IS NOT IN
CONFORMANCE WITH SHOP DRAWINGS. APEX'S LIABILITY EXTENDS
ONLY TO REPLACEMENT OR CORRECTION OF MATERIAL.
3) DOORS AND FRAMES WILL BE REINFORCED FOR SURFACE
MOUNTED HARDWARE AS REQUIRED. DRILLING AND TAPPING FOR
ATTACHING OF SURFACE MOUNTED HARDWARE BY OTHERS.
DOORS AND FRAMES WILL BE BLANKED, REINFORCED, DRILLED
AND TAPPED FOR MORTISED TEMPLATED HARDWARE.
TRIM MOUNTING HOLES AND ALL HOLES 1/2"n [12.7mm] AND LESS
BY OTHERS.
14) GENERAL CONTRACTOR IS RESPONSIBLE TO ENSURE
FRAMES AND DOORS ARE SET PLUMB, SQUARE, AND LEVEL
4) PLEASE ANSWER ALL QUESTIONS IF ANY ARE NOTED.
5) FURNISHING AND INSTALLATION OF GLASS AND
GLAZING IS BY OTHERS.
6) ALL DOORS AND FRAMES WILL BE MARKED WITH THE
ARCHITECT'S NUMBER ON THE SECOND HINGE FROM THE
TOP UNLESS SPECIFIED OTHERWISE.
7) UNLESS NOTED OTHERWISE, ALL HOLLOW METAL FRAMES
SHALL BE OF WELDED CONSTRUCTION.
8) ALL FRAMES WILL BE PREPARED FOR PUSH-IN TYPE
SILENCERS, 3 PER STRIKE JAMB FOR SINGLE FRAMES OR
2 PER HEAD FOR DOUBLE FRAMES.
9) ALL HARDWARE LOCATIONS ON THE DOORS & FRAMES WILL
BE APEX'S STANDARD LOCATIONS UNLESS ADVISED OTHERWISE.
10) ALL DETENTION HARDWARE FOR DOORS & FRAMES ARE
CENTERED IN A 2" (50mm) DOOR.
12) ON PAIRS OF DOORS, PLEASE INDICATE ACTIVE LEAF.
15) FIELD SHIMMING MAY BE REQUIRED ON SITE BY THE INSTALLATION
CONTRACTOR TO OBTAIN THE DESIRED CLEARANCES.
16) APEX, AS A MANUFACTURER OF ONLY HOLLOW METAL DOORS
AND/OR PRESSED STEEL FRAMES, CAN NOT CONTROL
THE QUALITY OF EITHER THE HARDWARE, THE FIELD INSTALLATION
OF HARDWARE, OR THE PROPER ERECTION OF FRAMES IN THE WALL.
17) APEX WILL NOT ACCEPT ANY RESPONSIBILITY FOR
PRODUCT DAMAGED ON SITE OR IN SHIPPING. ALL PRODUCT
RECEIVED ON SITE MUST BE INSPECTED FOR DAMAGE AT TIME
OF DELIVERY (WHILE DELIVERY TRUCK IS STILL ON SITE).
ANY DAMAGED GOODS MUST BE SHOWN TO TRUCK DRIVER
AND MARKED ON CARRIERS WAYBILL.
18) NO ADDITIONS, DEDUCTIONS, MODIFICATIONS, OR
BACK CHARGES WHATSOEVER WILL BE HONOURED BY APEX
UNLESS AUTHORIZED IN ADVANCE IN WRITING
AS TO EXTENT, TIME, AND PRICE.
19) a)PLEASE ADVISE IF A FIELD SPLICE IS REQUIRED
b)PLEASE CONFIRM ALL THROAT OPENINGS & ANCHOR TYPES
c)PLEASE CONFIRM REMOVABLE STOP SIDE PUSH OR PULL
DOOR & FRAME DIVISION
DRAWN BY:
WORK ORDER #:
mcsteeves
PETRA DETENTION GROUP
DRUG LOO SLIDING DOOR
DATE CREATED:
11/5/2012
FILE NUMBER:
PAGE:
2
ANCHOR TYPES
DOOR AND FRAME HANDING CHART
TO DETERMINE HAND(SWING) OF DOOR AND FRAME
STAND OUTSIDE - FACING DOOR
INSIDE
FIRE RATING LABELS
A - 3 HOUR
B - 1 1/2 HOUR
C - 45 MINUTE
20M - 20 MINUTE
INSIDE
D OOR C ORE S
KS
STANDARD FIXED
BASE ANCHOR
STEEL STUD
ANCHOR
OUTSIDE
OUTSIDE
RIGHT HAND
LEFT HAND
INSIDE
KS
OUTSIDE
RIGHT HAND REVERSE
CORRUGATED TAIL
ANCHOR
DOOR EDGE OPTIONS
INSIDE
KS
OUTSIDE
LEFT HAND REVERSE
INSIDE
INSIDE
INACTIVE
INACTIVE
OUTSIDE
PAIR OF DOORS
LH ACTIVE
EXISTING WALL
ANCHOR
FTT / FBT - FLUSH TOP/BTM TACKED
FTF / FBF - FLUSH TOP/BTM TACKED & FILLED
FTW / FBW - FLUSH TOP/BTM CONTINUOUSLY WELDED
STEEL TYPES
KS
OUTSIDE
PAIR OF DOORS
RH ACTIVE
A40 - GALVANEAL A40
G90 - BRIGHT GLAVANIZED G90
R E M O V A B LE S TO P S
PL - PULL SIDE OF DOOR
PS - PUSH SIDE OF DOOR
INSIDE
INSIDE
INACTIVE
INACTIVE
ANCHOR TYPES
SLIDING DOOR HANDING
KS
KS
SLR OPENS TO THE RIGHT
OUTSIDE
PAIR OF DOORS
LHR ACTIVE
SLL OPENS TO THE LEFT
EL - INTERLOCKING SEAM EXPOSED
FL - INTERLOCKING SEAM FILLED
TL - INTERLOCKING SEAM TACK & FILLED
TS - INTERLOCKING SEAM TACKED
CW - CONTINUOUSLY WELDED SEAM
DOOR TOP/BTM OPTIONS
WOOD STUD
ANCHOR
KS
CONCRETE BLOCK WALL
WIRE ANCHOR
HCB - HOLLOW METAL DOOR - HONEYCOMB
IHM - INSULATED HOLLOW METAL DOOR - POLYSTYRENE
SFW - WELDED STEEL STIFFENERS - FIBERGLASS
WD- WOOD DOOR
SPW - WELDED STEEL STIFFENERS - POLYSTYRENE
KS
OUTSIDE
PAIR OF DOORS
RHR ACTIVE
* KS IS THE KEYSIDE OF DOOR (PLEASE CHECK ALL
SWINGS TO ENSURE KEY IS ON PROPER SIDE OF DOOR)
DOOR & FRAME DIVISION
SS - STEEL STUD ANCHOR
CT - CORRUGATED TAIL ANCHOR
WS - WOOD STUD ANCHOR
EWA - EXISTING WALL ANCHOR
.
DOOR SWINGS
LH - LEFT HAND
LHR - LEFT HAND REVERSE
RH - RIGHT HAND
RHR - RIGHT HAND REVERSE
DRAWN BY:
WORK ORDER #:
mcsteeves
PETRA DETENTION GROUP
DRUG LOO SLIDING DOOR
DATE CREATED:
11/5/2012
FILE NUMBER:
PAGE:
3
DOOR ELEVATION
FLUSH 12GA CHANNEL
TOP & BOTTOM
CONTINUOUSLY WELDED
1
1002.0
175.0
115.0
240.0
1
600.0
G
1978.0
115.0
G
E
FOOD/HANDCUFF PASS THRU
SEE PAGE 5
323.0
356.0
323.0
1227.0
960.0
FLOOR
DOOR CONSTRUCTION
SEE PAGE 6
SL
FLOOR
ID
ES
LE
FT
89.0 UNDERCUT
TO
CL
OS
E
REVISION HISTORY
REV
DATE
12/19/2012
1
DOOR & FRAME DIVISION
DRAWN BY:
WORK ORDER #:
mcsteeves
PETRA DETENTION GROUP
DRUG LOO SLIDING DOOR
DATE CREATED:
11/5/2012
FILE NUMBER:
PAGE:
4
F
PASS THRU & GLAZING DETAILS
LOCK BY OTHERS
6mm LOCK
R/F
369.0
356.0
19.5
115.0 149.0
54.0
33.0
14.5
115.0
HINGES BY OTHERS
F
DETAIL E
SCALE 0.3125
5.0 PASS THRU
PLATE
SHIPPED LOOSE
12GA CHANNELS
ALL FOUR SIDES
GLAZING POCKET
PLEASE CONFIRM
SIZE = 12.5
10GA GLASS TRIM
6mm HINGE
R/F
25.0
12GA DOOR
SKINS
HINGE SHIM
SHIPPED LOOSE
12GA GLASS TRIM
1/4-20 x 3/4" BUTTON HEAD
TORX MACHINE SCREW
SECTION G-G
SCALE 1
50.0
12GA. DOOR SKINS
50.0
DOOR & FRAME DIVISION
SECTION F-F
SCALE 0.5
DRAWN BY:
WORK ORDER #:
mcsteeves
PETRA DETENTION GROUP
DRUG LOO SLIDING DOOR
DATE CREATED:
11/5/2012
FILE NUMBER:
PAGE:
5
DOOR CUT THROUGH SECTION
SPOT WELDS @
76 O.C. TYP.
SPOT WELDS @
76 O.C. TYP.
TOP SKIN PROFILE
12GA. PERIMETER
CHANNEL
16GA
102.0
MAX
SPOT WELDS @
76 O.C. TYP.
SPOT WELDS @
76 O.C. TYP.
12GA. PERIMETER
CHANNEL
102.0
BOTTOM SKIN PROFILE
0.125 in
[3 mm]
BEVEL IN 2 in
[50 mm] DOOR
CONTINUOUS WELD
ALONG SEAM
WELD
12GA. SKINS
TOP & BOTTOM SKIN ASSEMBLY PROFILE
DOOR & FRAME DIVISION
DRAWN BY:
WORK ORDER #:
mcsteeves
PETRA DETENTION GROUP
DRUG LOO SLIDING DOOR
DATE CREATED:
11/5/2012
FILE NUMBER:
PAGE:
6
3224 Mobile Highway
Montgomery, AL 36108-4454
Tel: 334-281-8440
Fax: 334-286-4320
Website: www.airteqsystems.com
A Division of Norment Security Group
7205 TRACKSET PLAN VIEWS & ELEVATIONS
ISSUE
FOR BY
FILE
AND FIELD
/ PRODUCTION
( SUPPLIED
DEPARTMENTAL
REPRESENTATIVE
)
12/5/2012
12/5/2012
FOR APPROVAL
SLIDING DEVICE SUBMITTAL
VERIFICATIONS, COMMENTS, AND EXCEPTIONS
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------1. The devices are designed as described below. Please verify acceptability (Architect, GC, etc.).
 Airteq 7205 Manual Trackset – (1) Total
 Sloped Top Hinged Housing Cover
 Plan Views and Elevations are shown with values in Metric. ALL conversions are made using calculated values. Please review
carefully.
 The contract documents dictate a Mogul Override in the jamb – a 152.4 mm jamb is required for a Mogul Override and is shown as
being mounted OUTSIDE the door opening maintaining the 900 mm COW.
 The contract documents on Sheet A1 indicate an Internal Keyswitch to the Mogul Override, however, the 7205 Trackset is totally
mechanical in operation and has no means of electrically moving the door.
 Please see ‘Sliding Device Schedule’ for frame opening sizes, clear opening sizes, and device handing, ALL DIMENSIONS MUST
BE CONFIRMED AND APPROVED PRIOR TO RELEASE FOR MANUFACTURING.
2. Specific Installation and Typical “Customer Inquiry” Comments:
 Airteq Sliding Devices are handed by the direction of door CLOSE. EX: A door closing to the Right as seen from the Track Side
(Operator Side) of the opening is a Right Close (R/C) device.
 The Back plate of the device housing can be bolted directly to a masonry wall. At each bolt location, the block must be fully grouted.
When bolts (anchors) are used, they must not stick out from the Backplate on the lower row of holes to allow for proper clearances.
 Note: Airteq does not supply an exterior device which contains a hinged cover unless the area is completely protected from the
elements.
NOTE: MANUFACTURING LEAD TIME FOR DEVICES IS FOURTEEN (10) WEEKS FROM RECEIPT OF APPROVED
DRAWINGS AND ALL INFORMATION REQUIRED TO COMPLETE DEVICE CONSTRUCTION.
DEVICES WILL NOT BE BUILT UNTIL A RETURNED APPROVED SUBMITTAL IS RECEIVED.
REVERSE PLAN
REVERSE VIEW
152.4 mm
REVERSE PLAN
SLIDING DEVICE SCHEDULE
Project
DRUG LOO SLIDING DOOR - KENT
INSTITUTION
Job No.
TBA
Date
5-Dec-12
Opening
No.
DL-1
Location
Mark
No.
H1
Model
No.
7205
Fire
Label
N
Key Cylinder
Keyswitch
End Plates
Architect Door Size
Device Opening
Door
Frame
Slide
R/C
(SI Units)
Dimensions
Cylinder Type Integral to Secondary Left
Actual Size
Opening Size
Chart
Track O.T.
Right
COW
DMH
JW
DOL
PD
DT
HL
UC
DPW
DPH
Width
Height
M
P
Override
P or M
Height
Side Side B
No.
Side Side Width
X
17
X
X
X
X
900.000
2076.000 900.000 2076.000 152.400 76.200 25.400 50.800 2148.920 88.900 1001.600 1977.575 900.000 2076.000
L/C
Leading
Edge
Back
Edge
Header Rec.v Angle
Anchor
Anchor
Holes
Holes
1060.172 1088.747
Y
Y
Lock
Column
Width (mm)
44.450
Hinged Slope vs.
Door
FP
Cover
Flat
Guide
Notch
Top
Options
Y
Sloped SHM(SHORT)
N
Job
Notes
Sheet 1
Facility Name
Address
City,ST.,Zip
Airteq Job Number
WARRANTY
Airteq Systems warrants that its products shall be free defects in material and workmanship for a period of
One (1) year from the date of
to
. This warranty does not supplant normal
inspections, care and service of the products, nor does it apply to defects in the product caused by abuse,
misuse, accident, casualty, alteration, neglect, misapplication, installation not in accordance with published
instruction manuals or repair not authorized by Airteq Systems. All claims under this warranty must be
made in writing and must be received by Airteq Systems within the warranty period. Upon receipt of a
timely claim, Airteq Systems will inspect the products claimed to be defective, and repair, or at its option,
replace free of charge, any products or parts thereof, which Airteq Systems determines to be defective. If
the circumstances are such as to preclude, at Airteq Systems’ sole discretion, the remedying of warranted
defects by repair of replacement, Airteq Systems will, at its option, refund the purchase price. In no event
shall Airteq Systems’ liability for defective material exceed the actual replacement cost. Airteq Systems’
obligation hereunder is limited to repair, inspection or replacement of defective material at its factory in
Montgomery, Alabama, USA, and in no event will the undersigned be liable for any consequential, special,
or incidental damages whatsoever. Nonpayment of invoices will void any and all warranties.
THE WARRANTIES SET FORTH IN THIS ARTICLE ARE EXCLUSIVE AND IN LIEU
OF ALL OTHER WARRANTIES WHETHER STATUTORY, EXPRESS OR IMPLIED
(INCLUDING ALL WARRANTIES OF MERCHANTABLITILTY OR FITNESS FOR A
PARTICULAR PRUPOSE AND WARRANTIES ARISING FROM COUSRE OF
DEALING OR USAGE OF TRADE.) Correction of the nonconformities in the manner for the time
period ser forth in this warranty shall constitute Airteg Systems’ sole liability and Purchaser’s exclusive
remedy for defective or nonconforming product, whether the claims are based in contract, in tort (including
negligence and strict liability) or otherwise.
Issuance Date: ________________
By: ________________________
Title:
Airteq Systems
3224 Mobile Highway, Montgomery, AL 36108-5840
(334) 281-8440 – (334) 286-4320