ISOLUTE accessories and filtration products for sample preparation ®

ISOLUTE® accessories and filtration
products for sample preparation
This product bulletin details ordering information for the full range of IST’s accessories and
filtration products used in sample preparation applications, combinatorial chemistry and
parallel synthesis.
CONTENTS
ISOLUTE SPE accessories
Column adaptors
2
Column caps
2
PTFE stopcocks
12
Reservoirs
3
Frits
4-5
Frit insertors
5
ISOLUTE filtration products
Single fritted columns
6-8
Double fritted columns
9
Phase separators
10
Wide mouth filtration reservoir
10
High throughput ISOLUTE 96-well filtration products
Fixed well filtration plates
14
®
ISOLUTE Array filtration plates (flexible well) and accessories
14-15
Phase separator plates
15
®
Processing manifold, VacMaster -96
17-18
Processing stations for filtration, flash and SPE columns
VacMaster-10 and -20 vacuum manifolds
for SPE and filtration column processing
11-12
®
FlashVac -10 and -20 vacuum manifolds
for processing larger flash and filtration columns
13
VacMaster-96 for high throughput 96-well plate processing
17-18
Gravity rack for gravity processing of phase separators
and filtration columns
19
1
ISOLUTE column accessories
Column adaptors
4
ISOLUTE column adaptors (PTFE
or polyethylene (PE)) can be used
to connect any Luer tipped reser3
voir for filtration column to any
standard reservoir (A-J)
5
1
2
Ordering information for ISOLUTE column adaptors
Part number
Description
120-1100
120-1104
120-1101
120-1102
120-1103
120-1106
PTFE adaptors (A, B, C, G, H)
PTFE adaptor - 6 ml glass column
PE adaptors (A, B, C)
PE adaptors (D, E)
PE adaptor (F)
PTFE adaptor (J)
Units /
pack
1
5
2
3
4
10
10
10
10
10
5
Column caps
ISOLUTE column caps can be
used to seal the top and bottom of
all IST’s column configurations
(A-J)
Ordering information for column caps
Part number
Description
1201-0120
1201-0121-A
1201-0122-B
1201-0123-C
1201-0124-G
1201-0125-H
1201-0126-D
1201-0127-E
1201-0128-F
1201-0129-J
Luer tip caps *
1 ml tube caps
3 ml tube caps
6 ml tube caps
10 ml tube caps
10 ml tube caps
15 ml tube caps
25 ml tube caps
70 ml tube caps
150 ml tube caps
Units /
pack
100
100
100
100
100
100
100
100
100
50
* fits all column sizes
2
Standard ISOLUTE column reservoirs
Available in 11 columns sizes, including
high throughput 96-well formats (see pages
14-15)
ISOLUTE column reservoirs are
standard grade (SG) and
available empty or fritted in order
analytical grade (AG).
to meet the demands of many
The SG formats are lower cost and
filtration and combinatorial
clean enough for most filtration
chemistry applications. They can
applications. AG reservoirs are
be fitted to any industry standard
cleaned specifically for high
SPE columns by means of column
sensitivity applications. It is
adaptors.
recommended that the SG
They are available in two levels of
reservoirs are evaluated first.
cleanliness -
Standard grade (SG) empty reservoirs
Part number
Description
Units /
pack
120-1101-A
120-1102-B
120-1103-C
120-1104-G
120-1105-H
120-1106-D
120-1107-E
120-1109-F
120-1110-J
SG Empty reservoir 1 ml
SG Empty reservoir 3 ml
SG Empty reservoir 6 ml
SG Empty reservoir 10 ml
SG Empty reservoir 10 ml
SG Empty reservoir 15 ml
SG Empty reservoir 25 ml
SG Empty reservoir 70 ml
SG Empty reservoir 150 ml
100
100
100
50
50
100
100
50
25
Analytical grade (AG) empty reservoirs
Part number
Description
120-1001-A
120-1002-B
120-1003-C
120-1004-G
120-1005-H
120-1006-D
120-1007-E
120-1009-F
AG Empty reservoir 1 ml
AG Empty reservoir 3 ml
AG Empty reservoir 6 ml
AG Empty reservoir 10 ml
AG Empty reservoir 10 ml
AG Empty reservoir 15 ml
AG Empty reservoir 25 ml
AG Empty reservoir 70 ml
Units /
pack
100
100
100
50
50
100
100
50
3
Frit materials
IST’s filtration products are based
multidirectional channel system.
a filter. The paths of the pores
on fritted systems consisting of
This enables the material to act as
prevent particles from passing
sintered particles (e.g.
straight though the material (as
polyethylene (PE) or PTFE),
they do in a membrane). For this
which are compressed to produce
reason, a frit of nominal or mean
a porous material. Pores run
pore size, e.g. 20 µm, can retain a
through the material in a
high percentage of particles
smaller than 20 µm in size. See
pages 4-5 for PE, PTFE and
stainless steel frit ordering
information.
Polyethylene frits are available in
various pore sizes. The standard size
Stainless steel frits for high
is 20 µm, and is ideal for most
sensitivity applications
general filtration applications
Frit material
porosity
Percentage retention of particles
1-3 µm
3 µm
5 µm
8 µm
15 µm
20 µm PE
N/A
10%
70%
90%
>99.9%
10 µm PE
99%
99%
>99%
>99%
>99.9%
20 µm PTFE
99%
>99%
>99%
>99%
>99.9%
10 µm PTFE
99%
>99%
>99%
>99%
>99.9%
5 µm PTFE
99%
>99%
>99%
>99%
>99.9%
Particle retention with various frit materials and porosities
Polyethylene frits - 20 µm porosity
Part number
Description
120-1031-A
120-1033-B
120-1032-G
120-1034-H
120-1035-C
120-1036-D
120-1037-E
120-1038-F
120-1039-J
1 ml frit - 6 mm diameter, 20 µm PE
3 ml frit - 9 mm diameter, 20 µm PE
10 ml frit - 6 mm diameter, 20 µm PE
10 ml frit - 9 mm diameter, 20 µm PE
6 ml frit - 13 mm diameter, 20 µm PE
15 ml frit - 16 mm diameter, 20 µm PE
25 ml frit - 20 mm diameter, 20 µm PE
70 ml frit - 27 mm diameter, 20 µm PE
150 ml frit - 37 mm diameter, 20 µm PE
Units /
pack
100
100
100
100
100
100
100
100
50
Polyethylene frits - 10 µm porosity
Part number
Description
Units /
pack
120-1061-A
120-1062-B
120-1063-C
120-1064-G
120-1064-H
120-1065-D
120-1066-E
120-1067-F
120-1068-J
1 ml frit - 6 mm diameter, 10 µm PE
3 ml frit - 9 mm diameter, 10 µm PE
6 ml frit - 13 mm diameter, 10 µm PE
10 ml frit - 9 mm diameter, 10 µm PE
10 ml frit - 9 mm diameter, 10 µm PE
15 ml frit - 16 mm diameter, 10 µm PE
25 ml frit - 20 mm diameter, 10 µm PE
70 ml frit - 27 mm diameter, 10 µm PE
150 ml frit - 37 mm diameter, 10 µm PE
100
100
100
100
100
100
100
100
50
4
PTFE frits - 5 µm porosity
Part number
Description
Units /
pack
120-1091-A
120-1092-B
120-1093-C
120-1095-D
120-1096-E
120-1097-F
1 ml frit - 6 mm diameter, 5 µm PTFE
3 ml frit - 9 mm diameter, 5 µm PTFE
6 ml frit - 13 mm diameter, 5 µm PTFE
15 ml frit - 16 mm diameter, 5 µm PTFE
25 ml frit - 20 mm diameter, 5 µm PTFE
70 ml frit - 27 mm diameter, 5 µm PTFE
100
100
100
100
100
100
PTFE frits - 10 µm porosity
Part number
Description
Units /
pack
120-1081-A
120-1082-B
120-1083-C
120-1085-D
120-1086-E
120-1087-F
1 ml frit - 6 mm diameter, 10 µm PTFE
3 ml frit - 9 mm diameter, 10 µm PTFE
6 ml frit - 13 mm diameter, 10 µm PTFE
15 ml frit - 16 mm diameter, 10 µm PTFE
25 ml frit - 20 mm diameter, 10 µm PTFE
70 ml frit - 27 mm diameter, 10 µm PTFE
100
100
100
100
100
100
PTFE frits - 20 µm porosity
Part number
Description
Units /
pack
120-1071-A
120-1072-B
120-1073-C
120-1075-D
120-1076-E
120-1077-F
1 ml frit - 6 mm diameter, 20 µm PTFE
3 ml frit - 9 mm diameter, 20 µm PTFE
6 ml frit - 13 mm diameter, 20 µm PTFE
15 ml frit - 16 mm diameter, 20 µm PTFE
25 ml frit - 20 mm diameter, 20 µm PTFE
70 ml frit - 27 mm diameter, 20 µm PTFE
100
100
100
100
100
100
PTFE frits - 40 µm porosity - fit 6 ml glass column only
Part number
Description
120-1073-L
6 ml PTFE frit - 13 mm diameter
Units /
pack
60
Stainless steel frits - 10 µm porosity
Part number
Description
Units /
pack
120-1041-A
120-1042-B
120-1043-C
120-1044-G
120-1045-H
1 ml stainless steel frit - 6 mm diameter
3 ml stainless steel frit - 9 mm diameter
6 ml stainless steel frit - 13 mm diameter
10 ml stainless steel frit - 6 mm diameter
10 ml stainless steel frit - 13 mm diameter
100
100
100
100
100
Frit insertors
These can be used to accurately place frits when self-packing columns. Available in all column sizes.
Part number
Description
Units /
pack
120-1151-L
120-1151-D
120-1151-E
120-1151-F
120-1151-J
6 ml glass column frit insertor*
15 ml frit insertor
25 ml frit insertor
70 ml frit insertor
150 ml frit insertor
5
5
1
1
1
* also fits 6 ml standard column
5
ISOLUTE filtration products
Fritted ISOLUTE filtration columns
ISOLUTE filtration columns are
• Single column filtration using
available fitted with a variety of
a Luer tipped syringe barrel
frit materials. Single or double
• Multiple sample processing
fritted formats, with either
using VacMaster (page 11-12)
standard grade (SG) or analytical
or FlashVac (page 13), or
grade (AG) cleanliness are
commercially available
available.
automation equipment
The filtration columns can be used
• High throughput filtration - see
pages 14-16
in the following ways:
• Stand alone filter or stacked on
top of an SPE column
Single fritted columns
Standard grade (SG) Single fritted reservoirs 20 µm PE
Part number
Description
Units /
pack
120-1111-A
120-1112-B
120-1113-C
120-1114-G
120-1114-H
120-1115-D
120-1116-E
120-1118-F
120-1119-J
SG Single fritted reservoir 1 ml - 20 µm PE
SG Single fritted reservoir 3 ml - 20 µm PE
SG Single fritted reservoir 6 ml - 20 µm PE
SG Single fritted reservoir 10 ml - 20 µm PE
SG Single fritted reservoir 10 ml - 20 µm PE
SG Single fritted reservoir 15 ml - 20 µm PE
SG Single fritted reservoir 25 ml - 20 µm PE
SG Single fritted reservoir 70 ml - 20 µm PE
SG Single fritted reservoir 150 ml - 20 µm PE
100
100
100
50
50
100
100
50
25
Analytical grade (AG) single fritted reservoirs 20 µm PE
Part number
Description
Units /
pack
120-1121-A
120-1122-B
120-1123-C
120-1124-G
120-1124-H
120-1125-D
120-1126-E
120-1128-F
AG Single fritted reservoir 1 ml - 20 µm PE
AG Single fritted reservoir 3 ml - 20 µm PE
AG Single fritted reservoir 6 ml - 20 µm PE
AG Single fritted reservoir 10 ml - 20 µm PE
AG Single fritted reservoir 10 ml - 20 µm PE
AG Single fritted reservoir 15 ml - 20 µm PE
AG Single fritted reservoir 25 ml - 20 µm PE
AG Single fritted reservoir 70 ml - 20 µm PE
100
100
100
50
50
100
100
50
6
Standard grade (SG) single fritted reservoirs 10 µm PE
Part number
Description
Units /
pack
120-1361-A
120-1362-B
120-1363-C
120-1365-D
120-1366-E
120-1367-F
120-1369-J
SG Single fritted reservoir 1 ml - 10 µm PE
SG Single fritted reservoir 3 ml - 10 µm PE
SG Single fritted reservoir 6 ml - 10 µm PE
SG Single fritted reservoir 15 ml - 10 µm PE
SG Single fritted reservoir 25 ml - 10 µm PE
SG Single fritted reservoir 70 ml - 10 µm PE
SG Single fritted reservoir 150 ml - 10 µm PE
100
100
100
100
100
50
25
Analytical grade (AG) single fritted reservoirs 10 µm PE
Part number
Description
Units /
pack
120-1161-A
120-1162-B
120-1163-C
120-1164-G
120-1164-H
120-1165-D
120-1166-E
120-1167-F
AG Single fritted reservoir 1 ml - 10 µm PE
AG Single fritted reservoir 3 ml - 10 µm PE
AG Single fritted reservoir 6 ml - 10 µm PE
AG Single fritted reservoir 10 ml - 10 µm PE
AG Single fritted reservoir 10 ml - 10 µm PE
AG Single fritted reservoir 15 ml - 10 µm PE
AG Single fritted reservoir 25 ml - 10 µm PE
AG Single fritted reservoir 70 ml - 10 µm PE
100
100
100
50
50
100
100
50
Standard grade (SG) single fritted reservoirs 5 µm PTFE
Part number
Description
Units /
pack
120-1391-A
120-1392-B
120-1393-C
120-1395-D
120-1396-E
120-1397-F
SG Single fritted reservoir 1 ml - 5 µm PTFE
SG Single fritted reservoir 3 ml - 5 µm PTFE
SG Single fritted reservoir 6 ml - 5 µm PTFE
SG Single fritted reservoir 15 ml - 5 µm PTFE
SG Single fritted reservoir 25 ml - 5 µm PTFE
SG Single fritted reservoir 70 ml - 5 µm PTFE
100
100
100
100
100
50
Analytical grade (AG) single fritted reservoirs 5 µm PTFE
Part number
Description
Units /
pack
120-1191-A
120-1192-B
120-1193-C
120-1195-D
AG Single fritted reservoir 1 ml - 5 µm PTFE
AG Single fritted reservoir 3 ml - 5 µm PTFE
AG Single fritted reservoir 6 ml - 5 µm PTFE
AG Single fritted reservoir 15 ml - 5 µm PTFE
100
100
100
100
120-1196-E
120-1197-F
AG Single fritted reservoir 25 ml - 5 µm PTFE
AG Single fritted reservoir 70 ml - 5 µm PTFE
100
50
Standard grade (SG) single fritted reservoirs 10 µm PTFE
Part number
Description
Units /
pack
120-1381-A
120-1382-B
120-1383-C
120-1385-D
120-1386-E
120-1387-F
SG Single fritted reservoir 1 ml - 10 µm PTFE
SG Single fritted reservoir 3 ml - 10 µm PTFE
SG Single fritted reservoir 6 ml - 10 µm PTFE
SG Single fritted reservoir 15 ml - 10 µm PTFE
SG Single fritted reservoir 25 ml - 10 µm PTFE
SG Single fritted reservoir 70 ml - 10 µm PTFE
100
100
100
100
100
50
7
Analytical grade (AG) single fritted reservoirs 10 µm PTFE
Part number
Description
Units /
pack
120-1181-A
AG Single fritted reservoir 1 ml -10 µm PTFE
100
120-1182-B
AG Single fritted reservoir 3 ml - 10 µm PTFE
100
120-1183-C
AG Single fritted reservoir 6 ml - 10 µm PTFE
100
120-1185-D
AG Single fritted reservoir 15 ml - 10 µm PTFE
100
120-1186-E
AG Single fritted reservoir 25 ml - 10 µm PTFE
100
120-1187-F
AG Single fritted reservoir 70 ml - 10 µm PTFE
50
Standard grade (SG) single fritted reservoirs 20 µm PTFE
Part number
Description
Units /
pack
120-1371-A
SG Single fritted reservoir 1 ml - 20 µm PTFE
100
120-1372-B
SG Single fritted reservoir 3 ml - 20 µm PTFE
100
120-1373-C
SG Single fritted reservoir 6 ml - 20 µm PTFE
100
120-1375-D
SG Single fritted reservoir 15 ml - 20 µm PTFE
100
120-1376-E
SG Single fritted reservoir 25 ml - 20 µm PTFE
100
120-1377-F
SG Single fritted reservoir 70 ml - 20 µm PTFE
50
Analytical grade (AG) single fritted reservoirs 20 µm PTFE
Part number
Description
Units /
pack
120-1171-A
AG Single fritted reservoir 1 ml - 20 µm PTFE
100
120-1172-B
AG Single fritted reservoir 3 ml - 20 µm PTFE
100
120-1173-C
AG Single fritted reservoir 6 ml - 20 µm PTFE
100
120-1175-D
AG Single fritted reservoir 15 ml - 20 µm PTFE
100
120-1176-E
AG Single fritted reservoir 25 ml - 20 µm PTFE
100
120-1177-F
AG Single fritted reservoir 70 ml - 20 µm PTFE
50
Glass reservoirs and columns
Glass reservoirs
Part number
Description
120-1011-L
120-1030-L
Empty 6 ml glass reservoir
6 ml glass reservoir fitted with single 20 µm PTFE frit
Units /
pack
30
30
8
Double fritted columns
Standard grade (SG) double fritted reservoirs 20 µm PE
Part number
Description
Units /
pack
120-1211-A
120-1212-B
120-1213-C
120-1214-G
120-1214-H
120-1215-D
120-1216-E
120-1217-F
120-1218-J
SG Double fritted reservoir 1 ml - 20 µm PE
SG Double fritted reservoir 3 ml - 20 µm PE
SG Double fritted reservoir 6 ml - 20 µm PE
SG Double fritted reservoir 10 ml - 20 µm PE
SG Double fritted reservoir 10 ml - 20 µm PE
SG Double fritted reservoir 15 ml - 20 µm PE
SG Double fritted reservoir 25 ml - 20 µm PE
SG Double fritted reservoir 70 ml - 20 µm PE
SG Double fritted reservoir 150 ml - 20 µm PE
100
100
100
50
50
100
100
50
25
Analytical grade (AG) double fritted reservoirs 20 µm PE
Part number
Description
Units /
pack
120-1021-A
120-1022-B
120-1023-C
120-1024-G
120-1024-H
120-1025-D
120-1026-E
120-1028-F
AG Double fritted reservoir 1 ml - 20 µm PE
AG Double fritted reservoir 3 ml - 20 µm PE
AG Double fritted reservoir 6 ml - 20 µm PE
AG Double fritted reservoir 10 ml - 20 µm PE
AG Double fritted reservoir 10 ml - 20 µm PE
AG Double fritted reservoir 15 ml - 20 µm PE
AG Double fritted reservoir 25 ml - 20 µm PE
AG Double fritted reservoir 70 ml - 20 µm PE
100
100
100
50
50
100
100
50
9
Speciality filtration products
Phase separators
for aqueous work-up purification
Phase separators are ISOLUTE
following organic synthesis.
columns and plates fitted with an
Ideal for processing on the IST
optimised frit material that easily
Gravity Rack (page 19). Can also
separates aqueous phases from
be processed on the VacMaster
chlorinated solvents under gravity.
and FlashVac processing
This range is particularly suitable
manifolds (pages 11-13).
Phase separator columns
Part number
Description
Units /
pack
120-1901-A
120-1903-B
120-1905-C
120-1906-D
120-1907-E
120-1908-F
120-1909-J
Phase separator 1 ml (A)
Phase separator 3 ml (B)
Phase separator 6 ml (C)
Phase separator 15 ml (D)
Phase separator 25 ml (E)
Phase separator 70 ml (F)
Phase separator 150 ml (J)
100
100
100
100
100
50
25
Wide mouth filtration
cleavage. Available fitted with
reservoir (50 ml)
polyethylene frits as standard. Can
Designed for use in applications
be processed on the VacMaster
where recovery of solid material is
and FlashVac processing
required, such as removal of solid
manifolds (pages 11-12 and 13
phase synthesis resins, and
respectively)
isolation of resins prior to
50 ml filtration reservoir
Part number
Description
Units /
pack
120-1120-K
50 ml filtration reservoir, 20 µm
25
∗
Phase separator plates and wells
∗
High throughput filtration plates and wells
See high throughput section , pages 14-15, for details of these
products.
10
Processing stations for standard columns
VacMaster-10 and -20 processing stations
VacMaster vacuum manifolds are
designed to give optimal
flexibility, high purity and safety
in sample processing for all types
of SPE, filtration and
combinatorial chemistry
applications. For a full description
of the VacMaster manifolds and
the range of accessories, see pages
76-82 of the current IST
VacMaster-10 and -20 shown fitted with standard stainless steel needles (left) and optional PTFE
stopcock / needle system (right)
catalogue.
VacMaster-10 - for processing up to 10 samples simultaneously
Part number
Description
Units /
pack
121-1010
121-1012
121-1016
121-1027
Complete with 10 mm diameter collection tube rack
Complete with 12 mm diameter collection tube rack
Complete with 16 mm diameter collection tube rack
Complete with 27 mm diameter collection tube rack
1
1
1
1
VacMaster-20 - for processing up to 20 samples simultaneously
Part number
Description
Units /
pack
121-2010
Complete with 10 mm diameter collection tube rack
1
121-2012
Complete with 12 mm diameter collection tube rack
1
121-2016
Complete with 16 mm diameter collection tube rack
1
VacMaster accessories and replacement parts: needles and stopcocks for VacMaster-10 and -20
Part number
Description
Units /
pack
121-0001
121-0002
121-0003
121-0004
121-0005
121-0009
121-0009-S
121-0030
121-0031
PTFE stopcock needle
PTFE needle unit
Stainless steel needles
Stainless steel needle retainer
Port sealing plugs
Universal PTFE stopcock
PTFE stopcock - positive pressure*
Extended PTFE stopcock
Extended PTFE stopcock needle
10
10
10
10
30
10
10
10
10
* Option for combinatorial chemistry applications requiring positive pressures ≤ 15 psi
Components for VacMaster-10 and -20
Part number
Description
Units /
pack
121-0040
121-0041
121-0042
121-0045
VacMaster rack dome nut
VacMaster rack nut washer
VacMaster rack foot
VacMaster rack leg
5
5
2
2
11
Components for VacMaster-10
Part number
Description
Units /
pack
121-0043
121-1132
121-1133
121-1134
121-1135
121-1136
121-1137
121-1138
121-1143
121-1030
VacMaster-10 rack strap
VacMaster-10 rack 10 mm tubes
VacMaster-10 rack 12 mm tubes
VacMaster-10 rack 16 mm tubes
VacMaster-10 top/mid plate 10 mm
VacMaster-10 top/mid plate 12 mm
VacMaster-10 top/mid plate 16 mm
VacMaster-10 top/mid plate 27 mm
VacMaster-10 lower plate
VacMaster-10 silicone lid gasket
1
1
1
1
1
1
1
1
1
1
Components for VacMaster-20
Part number
Description
Units /
pack
121-0044
121-2161
VacMaster-20 rack strap
VacMaster-20 rack 10 mm tubes
1
1
121-2162
121-2163
121-2164
121-2165
VacMaster-20 rack 12 mm tubes
VacMaster-20 rack 16 mm tubes
VacMaster-20 top/mid plate 10 mm
VacMaster-20 top/mid plate 12 mm
1
1
1
1
121-2166
121-2173
121-2059
VacMaster-20 top/mid plate 16 mm
VacMaster-20 lower plate
VacMaster-20 silicone lid gasket
1
1
1
Vacuum pump and supplies
Part number
Description
Units /
pack
121-9115
121-9240
121-0010
121-2095
121-2096
121-2097
121-2098
121-2099
Vacuum pump - 115 / 60 Hz
Vacuum pump - 240 / 50 Hz
PTFE T - valve
VacMaster trap kit
1L flask with 1 side arm
Flask stopper with 1 tubing connector
1.5m of vacuum tubing
Replacement gasket
1
1
1
1
1
1
1
1
Universal stopcocks
withstand up to 15 psi positive
IST’s universal PTFE stopcocks
pressure is available for
are designed for easy flow control
combinatorial chemistry
for any vacuum manifold compati-
applications. VacMaster
ble with Luer tipped reservoirs and
compatible combined stopcock /
columns.
needles are also available. See
A universal stopcock that can
page 11.
Ordering information universal stopcock
Part number
Description
Units /
pack
121-0009
121-0009-S
Universal PTFE stopcock
Universal PTFE stopcock - positive pressure*
10
10
* Option for combinatorial chemistry applications requiring positive pressures ≤ 15 psi
12
Processing stations for larger columns
FlashVac®-10 and -20 manual processing stations
FlashVac sample processing
For further information, see pages
stations have been specifically
85- 86 of the current IST
designed to meet the needs of
catalogue.
scientists who process larger flash,
SPE and filtration columns. The
manifold has been designed to
hold larger volume collection
vessels that cannot be
accommodated in manifolds
designed for use with standard
SPE columns.
50 g / 150 ml ISOLUTE Flash Silica on a
FlashVac-10
FlashVac-10 for processing up to ten 150 ml columns simultaneously
Part number
Description
122-1019
FlashVac-10 complete with 19 mm, 10 position rack
122-1025
FlashVac-10 complete with 25 mm, 10 position rack
FlashVac-10 for processing up to twenty 25 ml columns or ten 150 ml columns simultaneously
Part number
Description
122-2019
122-2025
FlashVac-10 complete with 19 mm, 20 position rack
FlashVac-10 complete with 25 mm, 10 position rack*
* The 25 mm positions in the FlashVac-20 are staggered in order to accommodate ten 150 ml columns
See page 86 of the current IST catalogue for accessories and spare
parts ordering information
13
High throughput 96-well plate format
96-well SPE plates and filtration products
(see pages 14-15 and the IST catalogue for further details)
Fixed well filtration plates
Filtration plate—fixed well
Part number
Description
120-1021-P01
120-1021-P05
120-1022-P01
120-1022-P05
120-1081-P
96-well filtration plate (single 10 µm PE* frit)
96-well filtration plate (single 10 µm PE frit)
96-well filtration plate (single 20 µm PE frit)
96-well filtration plate (single 20 µm PE) x 5
20 µm polyethylene frits, 7 mm / 96 well plate
Units /
pack
1
5
1
5
100
* PE is polyethylene
Flexible well filtration
Filtration plate—removable wells
Plates
Part number
Description
Units /
pack
120-1000-P01
ISOLUTE Array base plate pk 1
1
120-1000-P05
ISOLUTE Array base plate pk 5
5
120-1001-RP
Empty ISOLUTE Array plate 1 ml
1
120-1001-TP
Empty ISOLUTE Array plate 2 ml
1
120-1010-RP
Single fritted ISOLUTE Array plate 1 ml, 20 µm PE
1
120-1010-TP
Single fritted ISOLUTE Array plate 2 ml, 20 µm PE
1
120-1040-RP
Single fritted ISOLUTE Array plate 1 ml, 10 µm PE
1
120-1040-TP
Single fritted ISOLUTE Array plate 2 ml, 10 µm PE
1
120-1030-RP
Single fritted ISOLUTE Array plate 1 ml, 5 µm PTFE
1
120-1030-TP
120-1020-RP
120-1020-TP
120-1025-RP
120-1025-TP
Single fritted ISOLUTE Array plate 2 ml, 5 µm PTFE
Single fritted ISOLUTE Array plate 1 ml, 10 µm PTFE
Single fritted ISOLUTE Array plate 2 ml, 10 µm PTFE
Single fritted ISOLUTE Array plate 1 ml, 20 µm PTFE
Single fritted ISOLUTE Array plate 2 ml, 20 µm PTFE
1
1
1
1
1
14
Wells
Part number
Description
Units /
pack
120-1001-R
Empty ISOLUTE Array wells 1 ml
100
120-1001-T
Empty ISOLUTE Array wells 2 ml
100
120-1010-R
120-1010-T
120-1040-R
120-1040-T
120-1030-T
120-1020-R
120-1020-T
120-1025-R
120-1025-T
Single fritted ISOLUTE Array wells 1 ml, 20 µm PE
Single fritted ISOLUTE Array wells 2 ml, 20 µm PE
Single fritted ISOLUTE Array wells 1 ml, 10 µm PE
Single fritted ISOLUTE Array wells 2 ml, 10 µm PE
Single fritted ISOLUTE Array wells 2 ml, 5 µm PTFE
Single fritted ISOLUTE Array wells 1 ml, 10 µm PTFE
Single fritted ISOLUTE Array wells 2 ml, 10 µm PTFE
Single fritted ISOLUTE Array wells 1 ml, 20 µm PTFE
Single fritted ISOLUTE Array wells 2 ml, 20 µm PTFE
100
100
100
100
100
100
100
100
100
ISOLUTE Array Frits
Part number
Description
Units /
pack
120-1015-R
120-1060-R
120-1090-R
120-1080-R
120-1070-R
Frits, Array, circular, 20 µm PE
Frits, Array, circular, 10 µm PE
Frits, Array, circular, 5 µm PTFE
Frits, Array, circular, 10 µm PTFE
Frits, Array, circular, 20 µm PTFE
100
100
100
100
100
ISOLUTE Array Accessories
Part number
Description
120-1000-P01
ISOLUTE Array base plate
Units /
pack
1
120-1000-P05
ISOLUTE Array base plate
5
120-1200
Strip of 8 base plate plugs
50
120-1201
Luer adaptors
25
120-1202
Well removing tool
1
High throughout ISOLUTE
on the VacMaster-96. See page 10
phase separators
and the IST catalogue for full
The frit material use in these
product description.
products is optimised for the
For a ‘How to use guide’, request
separation of aqueous phases from
Technical Note TN122.
chlorinated solvents under gravity.
For ordering information see
The high throughput 96-well phase
overleaf.
separator plates can be processed
15
Part number
Description
Units /
pack
ISOLUTE fixed 96-well phase separator plates
120-1910-P01
Fixed 96-well phase separator plate, 2 ml
1
120-1910-P05
Fixed 96-well phase separator plate, 2 ml
5
ISOLUTE Array 96-well phase separator plates
120-1920-RP
Array 96-well phase separator plate, 1 ml
1
120-1920-TP
Array 96-well phase separator plate, 2 ml
1
ISOLUTE Array phase separator columns*
120-1920-R
Array phase separator columns, 1 ml
100
120-1920-T
Array phase separator columns, 2 ml
100
* To partially populate a plate, a base plate and base plate sealing plugs are required, See page 15 for ordering information
Other 96-well products
High capacity Array plates
organic synthesis in combinatorial
ISOLUTE HM-N Array
and wells for high
chemistry lead generation).
products for supported
throughput purification
Available packed with 400 mg
liquid-liquid extractions and
Large bed mass ISOLUTE Array
silica based sorbents, or 200 mg of
water removal
wells and plates are available for
resin based sorbent.
For full details, see the IST
applications requiring a higher
See PB0307 for further details.
catalogue or contact your IST
sorbent capacity for purification
distributor.
(e.g. purification following
16
Processing station for 96-well plates
VacMaster-96®
The VacMaster-96 vacuum
VacMaster trap kit
manifold is compatible with both
ISOLUTE-96 and ISOLUTE
Array plate formats. The
96-well plate
lightweight, solvent resistant
construction makes it ideal for
many high throughput sample
preparation procedures, including
protein precipitation sample clean
up following organic synthesis,
VCU-2
VacMaster-96
and phase separation applications
in combinatorial chemistry.
A solvent trap kit is available to
VacMaster-96 a fully integrated
remove and isolate hazardous
system for high throughput sample
The VacMaster-96 has a range of
waste solvents during sample
processing.
accessories specifically designed
processing.
to complete the range of 96-well
products. These include deep well
Vacuum control units are also
For more detailed information
collection plates and spacers for
available either with (see
about each of these products, see
compatibility with other
photograph above) or without
the current IST catalogue or
commercially available collection
integral vacuum generator.
contact your IST distributor.
plate designs.
These features make the
VacMaster-96 for processing up to 96 samples simultaneously
Part number
Description
VacMaster-96 manifold options
121-9600
VacMaster-96 (no vacuum controller included)
121-9603
VacMaster-96 with VCU-1 (121-9601)
121-9604
VacMaster-96 with VCU-2 (121-9602)
Vacuum control unit options
121-9601
VacMaster-96 vacuum control unit (VCU-1)
121-9602
VacMaster-96 Vacuum Control Unit with integral vacuum
generator (VCU-2)
Units /
pack
1
1
1
1
1
This option is supplied for use with automated liquid handling systems with an in-built computer controlled vacuum source
This option is for use in a laboratory with a vacuum source
This option is available for use in a laboratory with a compressed air source
17
VacMaster-96 accessories and replacement parts
Part
number
Description
Units /
pack
121-9610
121-9611
121-9612
121-9613
121-9614
121-9615
121-9616
ISOLUTE Array insert (6 mm) for VacMaster-96 (Acetal)
VacMaster-96 insert (12 mm) for 3M/Ansys plates (Acetal)
Replacement Gasket
Replacement 'o' ring
Collection plate spacer (2 mm) (for deep well format)
Collection plate spacer (shallow) (microtitre plate format)
ISOLUTE Array insert (6 mm) for VacMaster-96 (PVDF)
1
1
1
1
1
1
1
Supplied as standard with all VacMaster-96 units
For use in combinatorial chemistry applications using aggressive solvents
96-well collection plates - deep well
Part number
Description
Units /
pack
121-5201
Polypropylene, Square well - 350 µl / well
50
121-5202
Polypropylene, Square well - 1 ml / well
50
121-5203
Polypropylene, Square well - 2 ml / well
50
121-5204
Piercable Sealing Cap
50
121-5205
Drain Cap
25
VacMaster trap kit—can also be used with the VacMaster-10 and -20 processing stations
Part number
Description
121-2095
VacMaster trap kit
Replacement parts
121-2096
Flask with side arm
121-2097
Flask stopper with tubing connector
121-2098
Vacuum tubing
121-2099
Replacement sealing gasket
18
IST Gravity Rack for processing columns under gravity
Gravity processing
The system can be used for
This free standing system has been
processing IST’s phase separator
specifically designed for gravity
columns.
processing. All of the rack
Technical Note TN122 details the
components are made from
use of IST’s Phase separators.
solvent resistant polyethylene
materials. The 20-port rack can
It is also suitable for SPE
process up to twenty 25 ml (E)
applications where vacuum is not
columns simultaneously.
required.
Gravity Rack ordering information
Part number
Description
123-2010
123-2012
123-2016
123-2019
Complete with 10 mm diameter collection tube rack
Complete with 12 mm diameter collection tube rack
Complete with 16 mm diameter collection tube rack
Complete with 19 mm diameter collection tube rack
Components for Gravity Rack collection tube size conversion
Part number
Description
Units /
pack
123-2110
123-2112
123-2116
123-2119
123-2100
Top / mid plates for 10 mm diam. tubes
Top / mid plates for 12 mm diam. tubes
Top / mid plates for 16 mm diam. tubes
Top / mid plates for 19 mm diam. tubes
Blank top / mid plates for customized racks
2
2
2
2
2
Gravity Rack needle options
Part number
Description
Units /
pack
121-0001
121-0002
121-0003
121-0004
PTFE stopcock / needle unit
PTFE needle unit
Stainless steel needle
Stainless steel needle retainer
10
10
20
10
19
© 2001 International Sorbent Technology Ltd.
Distributed by:
International Sorbent Technology Ltd, Dyffryn Business Park
Hengoed, Mid Glamorgan, UK, CF82 7RJ
Tel: +44 (0) 1443 816656 Fax: +44 (0) 1443 816657
E-mail: info@ist-spe.com
PB0305
www.ist-spe.com
ISOLUTE, ISOLUTE Array, IST, VacMaster and FlashVac are registered
trademarks of International Sorbent Technology Limited.
20