Overview
The A8110 is an universal sample compartment designed
exclusively for the C11200 Picosecond Fluorescence Lifetime
Measurement System. The A8110 can be easily mounted on
an optical bench (with M6 holes at 50 mm pitch) or any
convenient bench using the A8111 base plate.
Interchangeable sample holders are available for cryostat,
semiconductor wafers, organic chemistry samples (solution
and film), and dewar units. To ensure the superb reproducibility,
the optical axis stays the same position even when
interchanging sample holders or mounting/removing samples.
● Four types of sample holders available
•
Cryostat holder: A8112 -01, -02
•
Semiconductor wafers holder: A8113
•
Organic chemistry samples (solution and film) holder: A8114
Dewar units: A8790
•
● High fluorescence collection efficiency
About 5 times brighter than conventional bifurcated fiber optics
● Excellent optical-axis reproducibility
Optical axis reproducibility when attaching/removing samples:
within 100 μm
Applications
● Excitation from either the left or right side
● Fluorescent spectral photometry
● FC connector input for excitation
● Phosphorescent spectral photometry
● Compatible with standard Ti-Sapphire laser, etc.
Example of system configuration
● External-laser excitation measurement system
● Nitrogen-laser excitation measurement system
Picosecond Fluorescence Lifetime Measurement System C11200
Picosecond Fluorescence Lifetime Measurement System C11200
Streakscope
C10627
Mount Table
A5206-08
Streakscope
C10627
Spectrograph
C11119-01
Mount Table
A5206-08
Spectrograph
C11119-01
A8110-01,-02
A8110-01,-02
Optical Trigger Unit Nitrogen Laser
C4792
Base plate A8111
Organic chemistry samples (solution and film) holder
A8114
Optical fiber with
both ends of FC connector
Base plate A8111
External laser
(Mode-locked
Ti-Sapphire laser, etc.)
Organic chemistry samples (solution and film) holder
A8114
Components
Part Number
Product name
Standard optics (over 370 nm)
A8110-01
Standard optics for UV (over 200 nm)
A8110-02
Base plate
A8111
DN1704 cryostat holder
A8112−01
(OXFORD INSTRUMENTS Cryostat)
Optistat DN cryostat holder
A8112−02
(OXFORD INSTRUMENTS Cryostat)
Semiconductor wafers holder
(Supports 3 inch wafers; comes supplied with vacuum chuck)
A8113
Organic chemistry samples (solution and film) holder
A8114
(10 mm square cell, 20 mm square film)
▲ DN1704 cryostat holder
A8112-01
Dewar units
(Liquid nitrogen cooling; three 10 mm square wafer samples can be mounted simultaneously.)
▲ Semiconductor wafers holder
A8113
A8790
Unit: mm
Base plate A8111
Spectrograph adapter
850±5
Mount table
A5206-08
Light collection optics
● Standard optics A8110
• Excitation optics
• Light collection optics
• Base plate for sample holder
● Organic chemistry samples (solution and film) holder A8114
• Sample holder
• 10 mm square cell holder
• Film holder
• Pseudo holder
Excitation optics
● Base plate
1000±5
Base plate for sample holder
10
280±5
160±2
Organic chemistry samples (solution and film) holder A8114
▲ Organic chemistry samples
(solution and film) holder
A8114
▲ Dewar unit
A8790
● Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with your local sales representative.
● Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications and external appearance are subject to change without notice.
© 2009 Hamamatsu Photonics K.K.
Homepage Address http://www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Systems Division
812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-433-8031, E-mail:export@sys.hpk.co.jp
U.S.A. and Canada: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1)908-231-0852, E-mail: usa@hamamatsu.com
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658, E-mail: info@hamamatsu.de
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10, E-mail: infos@hamamatsu.fr
United Kingdom:Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire, AL7 1BW, U.K., Telephone: (44) 1707-294888, Fax: (44) 1707-325777, E-mail: info@hamamatsu.co.uk
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 Solna, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01, E-mail:
info@hamamatsu.se
Cat. No. SHSS0009E01
Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E 20020 Arese (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741, E-mail: info@hamamatsu.it
DEC/2009 HPK
Created in Japan