pl od no e D uc t a o er v cu m a St lid e at nt em en t BALUSTRADE PRODUCER STATEMENT Specifically prepared on: 27th May 2011 For the following project; Project: Sa m Residence for M/M Arnold & Freda McGaffy SPECIFIERS NAME ABC Architecture 07 850 9464 07 850 9465 abcarchitecture@unex.co.nz Pr Company: Phone: Fax: E-mail: CLIENT DETAILS Name: Phone: Fax: E-mail: M/M Arnold & Freda McGaffy 09 987 6543 09 987 6542 afmcgaffy@vodafone.co.nz Specifications subject to change without notice phone 0800 333 777 | © Unex Systems 27th May 2011 Residence for M/M Arnold & Freda McGaffy 42 Medvale Avenue, Otara, Auckland Sa m pl Pr od no e D uc t a o er v cu m a St lid e at nt em en t Lot 2 - DP 10037 External Balustrading to first floor balcony Arena page 3.131.1, Arena page 4.111.5, Arena page 5.131.1, Arena page 2.9.3 STYLE SPECIFICATIONS ISSUE NO. 10 | PAGE 3.131.1 'METROPOLIS' (AZM MECHANICAL) - STYLE SPECIFICATION 3.131.1 This specification is for the ARENA ‘METROPOLIS’ (MECHANICAL) Style using the AZM channel. (1) Glass shall be GRADE A SAFETY GLASS, TOUGHENED in accordance with AS/NZS2208, with a minimum thickness as determined from Table below. Glass shall be supported and glazed in accordance with NZS4223. All exposed edges to be flat polished. (2) Further details on manufaccture and installation are given in other Chapters of this manual: Chapter 4 - Fixing details and spacing, Chapter 5 - General specification, Chapter 6 - Vertical dimensions, Chapter 7 - Corner connection for top rail, Chapter 9 - Installation instructions. (3) Each AGM2 clamping unit requires a slotted cut out of the glass to accommodate the top bolt in the unit. Refer also to Chapter 7 for further details on the requirements for using these units and also to Chapter 9 for the set out and spacing of the units for each glass pane. pl od no e D uc t a o er v cu m a St lid e at nt em en t (3) Top rail ends must be securely attached to walls or end posts. Where this is not possible, the glass thickness and Clamping Set Centres of end panes must be as per the equivalent ‘Panorama’ style. The balustrade shall be fabricated from the following items: TOP RAIL: ART / PZT. HEIGHT ‘H’ TOUGHENED GLASS PANELS. See Table Below. GLAZING CHANNEL: AZM. COVER: AVM. CLAMPING UNITS: AGM2. Sa m SUBSTRATE LEVEL (as defined by the Fixing Specification) MINIMUM TOUGHENED GLASS THICKNESS (Millimetres) & CLAMP CENTRES Description (Note 2) (Note 4) Minimum Glass Thickness 1 Pr 1.0 Line No. HEIGHT LOADING CLASS 1.1 1.2 Maximum Clamping Set Centres 2 Minimum Glass Thickness 3 Maximum Clamping Set Centres 4 Minimum Glass Thickness 5 Maximum Clamping Set Centres 6 A1 (Note 1) R A2 Design Wind Speed (Note 3) M H VH 50 52 54 56 58 60 62 64 N/A 38 40 42 44 46 48 50 52 54 56 Design Wind Speed (Note 3) 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 phone 0800 333 777 | © Unex Systems 12 400 400 400 400 350 350 300 300 600 600 600 600 600 600 550 500 450 450 400 12 12 12 12 12 15 15 350 350 350 350 300 240 225 15 15 15 15 15 275 275 250 225 225 - - - - - - - - 12 12 12 12 12 12 12 12 12 12 12 600 600 600 600 550 500 450 400 400 350 350 12 12 12 12 500 500 500 500 12 12 12 15 15 15 15 450 400 400 275 275 250 225 (1) LOADING CLASS: Refer to Page 2.9.3 of this MANUAL for the scope of the Loading Class designations. (2) HEIGHT 'H': is the overall height of the balustrade above the substrate level shown. Interpolate for Heights between those shown. (3) DESIGN WIND SPEED: in m/s, Refer to Pages 3.8.1 to 3.8.6 for details of applicable wind codes and the methods for determining the Design Wind Speed for any particular site. (4) CLAMPING SET CENTRES: Figures given are the maximum spacing in mm. Refer to Chapter 9 for method of determining actual spacing required. Specifications subject to change without notice 12 FIXING SPECIFICATIONS ISSUE NO. 10.1 | PAGE 4.111.5 AZM, CONCRETE TOP MOUNTING - SPECIFICATION 4.111.5 pl od no e D uc t a o er v cu m a St lid e at nt em en t This specification is for fixing ARENA BALUSTRADES, ‘PANORAMA’ & ‘METROPOLIS’ (MECHANICAL) Styles to concrete substrates using the AZM channel. A separate specification must be referred to for the required balustrade style, (Refer to Chapter 3 of the ARENA MANUAL). Also refer to applicable notes on Page 4.100.1. (1) For details of approved fasteners refer to General Notes on Page 4.30.1 note 3 and note 6. AZM GLAZING CHANNEL, (2) Washers to be fitted under all stud nuts as AVM COVER & follows AGM1 CLAMPS For 8mm studs - 22mm O.D. S/S washer (Part No. FW8-22) with a polymer washer (Part No. FWP8-22G) between the S/S FASTENERS AS PER TABLE BELOW and the aluminium. For 10mm studs - 21mm O.D. S/S washer (Part No. FW10-21) with a polymer SUBSTRATE LEVEL 24mm washer (Part No. FWP10-22G) between = MAX t= p the S/S and the aluminium. topping (3) A level and uniform surface must be provided thickness beneath the Glazing Channel. The Glazing MINIMUM Channel is not recommended to be installed DEPTH OF d EMBEDMENT over tiles. (4) For fixing AZM channel to infill concrete in masonry bond beams, increase minimum 35mm edge distance (e) to 70mm and increase stud MIN embedment depth (d) by 15mm per fixing. i.e. for FE8 studs d = 95mm REINFORCED for FE10 studs d = 105mm e= CONCRETE SLAB (5) Fabrication and Installation are to be in accordance with the relevant requirements of the NZ Building Code, the ASSEMBLY SPECIFICATIONS in Chapter 5, the INSTALLATION INSTRUCTIONS in Chapter 9, and other applicable portions of the current ARENA FABRICATORS MANUAL. Sa m 60mm MIN (6) SUBSTRATE design, including waterproofing, structural adequacy of the slab and reinforcing, is beyond the scope of this specification. Concrete shall have a minimum 28 day Compressive Strength of 20MPa (as required for substrate design). (Note 3) Fastener - Qty and Type (Note 2) 1.0 1.1 1.2 (1) (2) (3) (4) 'd' (See diagram) Line No. Height Pr MAXIMUM SPACING OF FASTENERS (mm) LOADING CLASS (Note 1) A1 A2 R Design Wind Speed (Note 4) M H VH 50 52 54 56 58 60 62 64 N/A 38 40 42 44 46 48 50 52 54 56 Design Wind Speed (Note 4) 1 x FE8 80 1 400 400 400 400 350 350 1 x FE10 90 2 500 500 500 500 450 450 - - 500 500 500 500 500 500 500 500 500 500 500 1 x FE8 80 3 350 350 350 300 - - 500 500 500 500 500 500 450 400 350 350 300 1 x FE10 90 4 450 450 450 400 - - - - 500 500 500 500 500 500 500 500 500 450 400 1 x FE8 80 5 300 300 300 - - - - - 500 500 500 500 450 400 350 350 300 300 - 1 x FE10 90 6 400 400 400 - - - - - 500 500 500 500 500 500 500 450 400 400 - - - - - 500 500 500 500 500 500 500 500 450 400 400 LOADING CLASS: Refer to Page 2.9.3 of this MANUAL for the scope of the Loading Class designations. FASTENERS: Refer to Page 4.30.1 note 3 for general details. HEIGHT 'H': is the overall height of the balustrade above the substrate level shown. Interpolate for Heights between those shown. DESIGN WIND SPEED: in m/s, Refer to Pages 3.8.1 to 3.8.6 for details of applicable wind codes and the methods for determining the Design Wind Speed for any particular site. Specifications subject to change without notice phone 0800 333 777 | © Unex Systems ASSEMBLY SPECIFICATIONS ISSUE NO. 10 | PAGE 5.131.1 ‘METROPOLIS’ (MECHANICAL), AZM CHANNEL - ASSEMBLY SPECIFICATION Refer elsewhere for corners, slopes and other situations not illustrated here. See also the INSTALLATION GUIDE in Chapter 9. #ART OUTER TOP RAIL. #FS4-4B RIVETS. 1 pair at 1000mm maximum centres between. Drill size = 3.3mm Ø. pl od no e D uc t a o er v cu m a St lid e at nt em en t #PZT GLAZING INNER TOP RAIL. Silicone bond to top edge of glass. Note: A Top Rail is recommended to prevent glass breakage, by protecting the top edge from being struck by hard objects, especially for Public applications. #SWL12 WEDGE GASKET on both sides of 12mm #SWL10 for 10mm, or #SWL15 for 15mm glass. #SBC SETTING BLOCKS at 500mm centres to separate the top rail from the glass and prevent over-compression of the bonding silicone during rail placement. TOUGHENED GLASS PANELS of appropriate thickness, refer to the Style Specification. All exposed edges to be Flat Polished. SLOTTED CUT-OUT in glass is required at each #AGM2 clamping unit. Refer to page 7.61.3. Sa m FIXINGS (not shown) Refer to Fixing Specificaion for positions. #AGM2 CLAMPING UNITS (partly shown) are required to clamp the glass to the #AZM channel. These clamps allow some adjustment to the verticality of the glass infill. Refer to pages 7.61.1 and 7.61.2. WEDGE Use #SWL6 for 10mm glass, and #SRE for 12mm glass. (No wedge for 15mm glass). Pr #SRE RETAINED GASKET to the #AZM CHANNEL. Must be slid into channel prior to assembly. #SBA SETTING BLOCKS (not shown). One block at each end of every glass panel. #ANM CONNECTORS are required to connect the #AVM cover to the #AZM channel. These connectors are required at approximately 750mm spacing. Refer to page 7.63.1. #AZM GLAZING CHANNEL to be continuous wherever practical. Joins should align with glass panel joins wherever the substrate is not perfectly rigid. Joins shall be tightly butted together. #AVM COVER is to be connected to the #AZM channel using the #ANM connectors. Specifications subject to change without notice phone 0800 333 777 | © Unex Systems SPECIFIERS GUIDE ISSUE NO. 10 | PAGE 2.9.3 NZ BUILDING CODE COMPLIANCE (CONTINUED) CLAUSE B1, STRUCTURES CONTINUED Human Impact Loads Continued APPLICABLE LOADLOADING CLASS ING STANDARD SPECIFIC USES Domestic and Residential pl od no e D uc t a o er v cu m a St lid e at nt em en t All areas except those included under A2 OCCUPANCY FOR PART OF BUILDING A1 Areas not susceptible to overcrowding in office and Offices, storage and institutitutional buildings, work areas not included also industrial and storage elsewhere (see note 1) buildings. Areas where people may Stairs, landings, external congregate that are withbalconies, edges of roofs out obstacles for moving people and not susceptible etc. to overcrowding. AS/NZS 1170:2002 A2 All areas within or serving exclusively one dwelling including stairs, landings Domestic and Residential etc. but excluding external balconies and edges of roofs. Sa m Fixed platforms, walkways Offices, storage and and stairways for access work areas not included only (see note 2) elsewhere (see note 1) NZS 4203:1992 R (see note 3) Excludes Public areas of Residential Residential buildings Note 1: Areas “included elsewhere” include; areas where people may congregate with fixed tables or fixed seating or susceptible to overcrowding, retail areas, cinemas, grandstands, bars, discotheques, auditoria, shopping malls, assembly areas, studios etc. Specificatons for these areas are not included in this manual. Pr Note 2: For access to/and safe working areas at places normally used by operating, inspection, maintenance and servicing personnel. Note 3: Loading Class R may be used for buildings as stated where the building consent application is lodged on or before the 30th November 2008 (unless Territorial Authorities advise otherwise). For consent applications subsequent to the 30th November 2008 Classes A1 and A2 will apply. (continued on following Page) Specifications subject to change without notice phone 0800 333 777 | © Unex Systems pl od no e D uc t a o er v cu m a St lid e at nt em en t Unex Systems balustrade products are distributed throughout New Zealand via a network of companies that specialize in the fabrication and installation of these products. The role of the fabricator is to quote, site measure, fabricate and install the product. Pr Sa m Contact Unex Systems on 0800 333 777 or email info@unex.co.nz for the contact details of a fabricator in the region of this project. Specifications subject to change without notice phone 0800 333 777 | © Unex Systems
© Copyright 2024