SOLAR OFF-GRID SYSTEM MANUAL Sample AS 1000VA COTECH SOLAR GROUP LIMITED No. 580, Zhengli Rd, Yangpu District, Shanghai TEL:0086-21-55665687 FAX: 0086-21-55665634 WEBSITE:www.cotechsolar.com EMAIL:info@cotechsolar.com SOLAR OFF-GRID SYSTEM MANUAL TABLE OF CONTENTS 1.Product Introduction 1.1. Features Description ……………………………………………….….……1 1.2. Technical data……………………………………………………..….………1 1.3. Storage and Working environment…………………………………………2 1.4. Appliance……………………………………………………………………...2 2. Instruction of Installation 2.1. Before fixing………………………………..…………………………………2 2.2. Outside view of solar home system…………………….…………….……2 2.3. Install solar panel………………………………………………..………..….3 2.4. Connecting …………………………………………………….….…….…...4 3. USAGE INSTRUCTION 3.1. Outside view of power box………………………………………………….6 3.2. The system panel and setting value code explanation…………………..7 3.3. Using Method………………………………………………………………...8 4. Fault and Measures 4.1. The emergency measures of fault……………………………….…….…..9 4.2. Power box fault diagnosis and corrective measures………………….....9 4.3. Regular checking…………………………………………..……………..….9 5. Other notice 1 SOLAR OFF-GRID SYSTEM MANUAL 1.Product Introduction: Cotech Solar series Solar Power System adopts advanced technique from Germany, develop and design new generation Solar PV System: Simplified structure, reliable performance, easy operation. This Solar Power System can offer stable and reliable electricity to those regions where are short of power or even without power. 1.1. Features Description A. High Efficiency. Solar controller: Double Close-loop Controller (both voltage & current control). It ensures the solar panel charges the battery farthest. Experiment tells us, under the same environment and same load condition, this Solar Power System can save 15% solar panel. B. Driver of inverter, special micro-computer control way, its main circuit adopts latest advanced Intelligent Power Module (IPM), to provide a stable, accurate output voltage, offer high-quality, high reliability Power for a variety of terminal equipments. C. Mature protective function. There is a series of protective measures, including over-voltage & under-voltage DC input protection, against inversion of polarity DC input protection, over load & short-circuit AC output protection, overheating protection to assure the system is safe and reliable and excellent in performance. D. Humanized Human-Computer Interaction interface, with the inquiry function about failure and running state information 1.2. Technical data: ITEM Capacity Rate Output Power Output wave Output current Precision of output voltage Precision of output frequency False output wave of AC Power factor Overload ability Invert efficiency Output voltage Output frequency Maximum output power of solar Module Maximum output voltage of solar module Maximum output current of solar module Battery capacity Best output power everyday 2 SPEC 1000VA 800W Pure sine wave 3.6A(220V) / 7.3A(110V)) ±3% ±0.1% less than 3% 0.8 120%,30 seconds More than 85% AC220/110V 50/60HZ 800W 70V 11.4A 48V240AH 2920WH SOLAR OFF-GRID SYSTEM MANUAL 1.3. Storage and Working environment A. Storage To avoid possible damage, take notice of the following items when restoring. a. Placed in the ventilation and away from dust and dirt area; b. Environmental temperature: Inverter & Battery: -10℃ ~ 50℃; Solar panel: -40℃~ 90℃; c. Relative moisture less than ninety percent, and without the phenomenon of drip congealed; d. Away from erosive gas and liquid; e. Long-period of no using, discharge and charge once six month. B. Working environment a. Working temperature: Inverter & Battery: -10℃ ~ 50℃; Solar panel: -40℃~ 90℃; b. Moisture: 0 ~ 90%; c. Elevation: ≤ 5000m; 1.4. Appliance Tour, nomads, families, boat, island, none or short of electricity area, Satellite Ground Stations, weather stations, forest fire stations, Border-guard Stations, etc. 3 SOLAR OFF-GRID SYSTEM MANUAL 2. Instruction of Installation 2.1. Before fixing (Fittings list) Part Power box Battery Solar panel Solar bracket Other SPEC 1000VA 12V120AH 17.5V100W QTY 1 pcs 4 pcs 4 pcs 2 set wires, MANUAL, CERTIFICATE, WARRANTY REGISTRATION CARD 2.2. Outside view of solar home system 4 SOLAR OFF-GRID SYSTEM MANUAL 2.3. Install solar panel Sketch map of solar panel bracket installation: S4 S1 S2 S5 STEP A: Install S1&S2&S3 STEP B: Install S4&S5&S6 S3 STEP C: Install solar panel STEP D: Cycle STEP A & B & C, finish installation 1. The installation place: no shadows on the surface of solar panel in the sunlight; 2. The angle: City: 5 SOLAR OFF-GRID SYSTEM MANUAL 2.4. Connecting A. Connection attention DANGER In order to avoid electrocution and fire hazards, pay attention to the follow: a. Before wiring, please make sure the switch on the power box is OFF. b. Please ask the professional electrical engineer to wire. c. Ground-connector must reliable. d. Make sure the wire connection is correct. e. Do not touch the terminals or circuit boards; do not short connect the terminals. f. The inverter AC output terminals with high-voltage, please keep it away from children. g. Do not increases, decrease, change the parts (especially solar panel, battery ) NOTICE a. Before connecting wire, please confirm the storage battery voltage is in accordance with the power box voltage. b. Connection order: power box – battery, then, power box – solar panel; cutting order: The inverter AC output terminals with high-voltage, please keep it away from children, then, power box – battery, or the system will be damaged. c. Please DO NOT do withstanding voltage test to the power box, or, the semi-conductor component and other devices will be damaged. d. All switches must in "OFF", check the load is short-circuited or not. B. Connection terminals 6 SOLAR OFF-GRID SYSTEM MANUAL a. Terminal explanation No. Name Function Wire size Connect with the battery + 6㎜2 1 BATTERY+ Connect with the battery 6㎜2 2 BATTERYConnect with PV output + 2.5 ㎜ 2 3 PV OUTPUT1 + Connect with PV output 2.5 ㎜ 2 4 PV OUTPUT1 Connect with PV output + 2.5 ㎜ 2 5 PV OUTPUT2 + Connect with PV output 2.5 ㎜ 2 6 PV OUTPUT2 Connect with AC output + 2.5 ㎜ 2 7 AC OUTPUT L Connect with AC output 2.5 ㎜ 2 8 AC OUTPUT N Connect with the ground 4㎜2 9 EARTH E Turn on/off solar panel / 10 PV1 Turn on/off solar panel / 11 PV2 Dissipate the heat inside of the / Radiator 12 case dissipation hole Notice: First connect the battery cable to the battery terminal, note the polarity, and then connect solar panel, lastly the load. b. Drawing of the solar panels connection c. Drawing of the batteries connection 7 SOLAR OFF-GRID SYSTEM MANUAL 3. USAGE INSTRUCTION 3.1. outside view of power box 3.2. The system panel and setting value code explanation No. 13 14 Name PV1 PV2 15 Inverter 16 Low voltage 17 Over voltage 18 Over load 19 20 21 22 23 Reset Output voltage Output current Switch Digital display Function Show whether PV input is connected or not Show whether PV input is connected or not Shows whether controller output is running or not (bright: running) Shows whether battery voltage is low-voltage or not (bright: low voltage) Shows the inverter output is over-load or short-circuit (bright: low voltage) Shows the inverter output is over-load or short-circuit (bright: over-load, flash: short-circuit) “stop/start” of the inverter Show AC output voltage Show AC output current Turn on or off the Inverter Display the status of system 8 SOLAR OFF-GRID SYSTEM MANUAL Setting value code explanation Code fs00 fs01 fs02 fs03 fs04 fs05 fs06 fs07 fs08 fs09 fs10 fs11 fs12 fs13 fs14 fs15 fs16 fs17 fs18 fs19 fs20 fs21 fs22 fs23 Parameter Battery over discharge voltage Battery over discharge and recover voltage Battery over-voltage Battery over-voltage recovery Battery mean charge voltage Battery floating charge protection voltage Battery voltage over high action value Mean charge protection voltage(using when system expands) Mean charge protection voltage(using when system expands) Charge current protection value Temporarily don’t, using when system expands Over-load current protection value Choice of charging loop quantity Modify password Recover leaving factory value Load short-circuit decrement gradually value Recommended load short-circuit value Show minute Show hour Show day Show power generation quantity on month Show discharge quantity on month Show power generation quantity on day Show discharge quantity on day 9 Setting value 43.2(v) can set 52.8(v) can set 70(v) can set 66(v) can set 52.8(v) can set 57.6(v) can set 60(v) can set / / 5.7(A) can set 0 20(A) no use 2 (way) 0-disable 1-enable 0-invalid 1-recover 100 (time) 100 (time) Can modify in pc Can modify in pc Can modify in pc / / / / SOLAR OFF-GRID SYSTEM MANUAL A. Fs13 is modifying password, if it is set “1”, namely allow setting, in order to prevent the not professional personnel mistaking operation, the controller has already changed into “0” before leaving factory. B. Fs14 is set “0”, if recovering leave factory value please set “1”. But value set by you isn’t being stored. C. The leave factory initial value is reference one, each storage battery over-charge and over-discharge voltage are different, please set by oneself or ask the storage battery supplier. D . When connecting the moment of storage battery, the all front panel nixie tube manifestation are bright, because at first, the micro-computer wants to carry on checking by oneself, if the controller isn’t used as long as time, checking by oneself isn’t finished, which is normal phenomenon, at this time cut storage battery, connect storage battery again. E. Digital access parameter values can be operated as follows: Press ”PROG”, nixie tube will show “PROG” again, and then press “READ” again, nixie tube shows the parameter value of “fs00” code; Press ”PROG” again, and then press” △”, nixie tube shows “fs00”, next press “READ”, nixie tube shows the parameter value of “fs01” code. The rest may be deduced by analogy, nixie tube can consult corresponding parameter value of fs00-fs23 code. “△” is up (or increment), “△” is down (or decrement). F. While modifying parameters, according to operation as follows: Firstly press “PROG”, secondly press “△”, until nixie tube shows “fs13”, if “fs13” shows “0”, and then press “△”, parameter will change “0” into “1”, next press “enter”, finally fs13 will be set successfully. G. In any state if you want to check battery voltage, please click “enter” button then you can view this state. 3.3. Using Method A. Power the load: a. Connect the load with ”AC output”; make sure the load is OFF. b. Turn the “Switch” ON, c. “Inverter” indicator light turns on,” Output voltage” shows the output voltage. The voltage of the electric appliance must be match this system. d. Turn on the load. B. Cut the load: a. Turn off the load. b. Turn the “Switch” OFF. C. Charging Connect the solar panel and power box. Notice: when the load is not working, make sure the Switch is OFF to save the power, 10 SOLAR OFF-GRID SYSTEM MANUAL 4. Fault and Measures 4.1. The emergency measures of fault A. B. C. D. Cut off solar panel wire; Cut off AC output loop; Cut off battery; Wait for two minutes or longer time and make sure the electric charge of capacitances is empty. E. Cut off boat-shaped switch and Reset button; 4.2. Power box fault diagnosis and corrective measures Fault Checking content measures Is the connection among the solar Solar panel can not panels, among the batteries, between Connect them again charge the solar panel and controller, between the battery and controller right? The Battery voltage LED Cut off the load, and Is it lack of power? is red. charge it timely. The over-load LED is Is the load running on over-power Decrease the load. bright The over-load LED is Is the load short circuit? Or is the Cut off the load flash temperature of radiator too high, When checking, please do firstly cut off the PV input, then the load, lastly cut off the battery, do not cut off battery before you don’t cut off solar. 4.3. Regular checking Components All terminals inside the machine Cycle One year content measure loosen Screw down dust and dunghill With 392 kPa - 588kPa pressure dry compressed air 5. Other notice A. Apart from professionals, do not carry on inspections and maintenance. B. Do not operate switch with wet hands, Do not using wet cloth to clean panels, against water inflow power box. C. Make sure the earth wire is connecting well. D. It is normal to have heat radiation during the power box working time, but keeps the install environment airiness, good heat dissipation, and clean, especially do not cover the ventilated window. E. The fan in the machine box is controlled by temperature, that the fan do not work is normal phenomenon when load is small. When temperature is higher than 50 ℃, the fan is running. F. Other circumstances please contact with us directly. 11
© Copyright 2024