® Sample Gas Pumps for Hazardous Areas P 2.2-ATEX, P 2.4 ATEX, P 2.2-AMEX, P 2.4 AMEX, P 2.82 AMEX, P 2.84 AMEX The transportation of sample gas in sample conditioning systems requires reliable sample pumps. The corrosive nature of the gas and the potential of condensate formation are the real challenges for any pump. § Robust and reliable design § Easy to replace valves These sample pumps are equipped with a bellows made from solid PTFE. This design has demonstrated the highest reliability and long lifetime in numerous applications. Designed specifically for harsh gas applications that have entrained liquids present or where condensate is expected to form, it is recommended that the pump head be pointed downwards to accommodate draining of these liquids § Bellow made of one solid piece § Suitable for corrosive gases § Pumps gases with entrained liquid § Low noise § Vibration dampening console § Optional adjustable bypass valve § Long life § ATEX versions for Category 2 § FM C-US approved versions for Class I Div. 2 A special flange design makes the P2.4 and P2.84 designs suitable for hot applications. The flange is designed in two parts -- one carrying the pump head is installed in a heated cabinet and the other carrying the electrical motor is flanged to the outside of the cabinet keeping the motor in ambient conditions. The pumps employ explosion-proof motors. The ATEX models are suitable for Category 2. The AMEX models are FM C-US approved and suitable for Class I Division 2. For easy installation, a support console with vibration dampers is included for the P 2.2 ATEX, P 2.2 AMEX and P 2.82 AMEX. DE 42 0009 05/2013 Page 1/5 Bühler Technologies GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 49 89-0 Fax: + 49 (0) 2102 / 49 89-20 Internet: www.buehler-technologies.com e-mail: analyse@buehler-technologies.com Overview of the basic pump models and links to further information One piece Pumps (see drawing 1) Nominal free flow (see flow curve) ATEX types (Europe) EX II 2 G Ex c IIC T1-T4 AMEX types (US) CL.I Div.2 Gr BCD T1-T4 FM C-US approval no. 3038101 / 3038101C 400 l/h (0.24 cfm) Pumps with intermediate flange (see drawing 2) 800 l/h (0.47 cfm) 400 l/h (0.24 cfm) P 2.2 ATEX P2.4 ATEX P2.2 AMEX Weight 800 l/h (0.47 cfm) P 2.82 AMEX P 2.4 AMEX P2.84 AMEX 7.5 kg 8.5 kg General technical data for all pumps Power supply Protection class see order number (page 3&4) Electrical IP 54 Mechanical IP 20 8.5 ml Dead space Pumps 400 l/h Pumps 800 l/h Ambient temperature Motors 115 V, 230 V Motor 380 - 420 V Pump head Media temperature valves* *see table below Nl/h vacuum Gas wetted materials: PTFE, PVDF (Standard pump with 100 °C valves) + PEEK (Standard pump with 140 °C valves) + Viton (Standard Pump with 100 °C valves and bypass valves) + PCTFE, Viton (Standard Pump with 140 °C valves and bypass valves) + 1.4571 (VA pump body) + 1.4401, Viton (VA pipe connections) Ambient temperature Motors 115 V, 230 V Motor 380 - 420 V Pump head PTFE/PVDF max. 100 °C (212 °F) Media temperature valves* -20 to 50°C (-4 to 122°F) -20 to 40°C (-4 to 104°F) see table below PTFE/PEEK max. 140 °C (284 °F) Nl/h vacuum bar (atm.) -20 to 50 °C (-4 to 122 °F) -20 to 40°C (-4 to 104°F) see table below PTFE/PEEK max. 120 °C (248 °F) bar (g.) bar (g) bar (atm.) 800 450 700 400 flow curve output output 300 250 200 A000013d 100 50 -0,6 -0,5 -0,4 -0,3 -0,2 -0,1 0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 at 60Hz + 10% flow P 2.2 ATEX and AMEX 200 100 0 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 at 60Hz + 10% flow Media temp. bar Restrictions for sample and ambient temperature Media temp. Media temp. Sample without flammable gases T3 T4 Sample with flammable gases T3 above the lower explosion limit T4 DE 42 0009 05/2013 Page 2/5 400 bar Restrictions for sample and ambient temperature Sample without T3 flammable gases T4 Sample with flammableT3 gases above the T4 lower explosion limit 500 300 150 P 2.4 ATEX and AMEX flow curve 600 A000124D 350 140 °C 120 °C 120 °C 50 °C (284 °F) (248 °F) (248 °F) (122 °F) P 2.82 AMEX Sample without flammable gases Sample with flammable gases above the lower explosion limit T3 T4 T3 T4 120 °C (248 °F) 80 °C (176 °F) 100 °C (212 °F) 50 °C (122 °F) T3 T4 T3 T4 Media temp. 120 °C (248 °F) 80 °C (176 °F) 100 °C (212 °F) 50 °C (122 °F) Pump head temp. 120 °C (248 °F) 100 °C (212 °F) 80 °C (176 °F) 80 °C (176 °F) 100 °C (212 °F) 80 °C (176 °F) 50 °C (122 °F) 50 °C (122 °F) P 2.84 AMEX Sample without flammable gases Sample with flammable gases above the lower explosion limit Pump head Temp. 100 °C (212 °F) 80 °C (176 °F) 80 °C (176 °F) 50 °C (122 °F) Ordering hints Atex: Part-no. 42 XX X X X X X 9 0 00 61 62 1 2 3 4 5 1 2 1 2 3 1 2 9 1 2 3 4 9 Feature Basic type P2.2 Atex 400l/h (II 2G Ex c IIC T3/T4) P2.4 Atex 400l/h (II 2G Ex c IIC T3/T4) Motor supply 230 V 50 Hz. 0,88 A 230 V 60 Hz. 0,89 A 115 V 50 Hz. 1,76 A 115 V 60 Hz. 1,78 A 380-400 V 50 Hz. 0,41 A Pump head position Normal pos. Vertical Pointing downwards * Pump head material PTFE SS 1.4571 PTFE with bypass valve * Valve material to 100 °C PTFE/PVDF * to 140 °C PTFE/PEEK Male stud couplings (depending on pump head) PTFE pump head Stainless steel pump head DN 4/6 (standard) 6 mm (standard) DN 6/8 8 mm 3/8” 3/8"-1/4” 1/4"-1/8" 1/4” 1/4"-1/6” Mounting accessories including mounting console and buffer * *not possible for P2.4 Atex Ordering hints AMEX: Part-no. 42 XX X X X X X 9 71 72 73 74 1 2 3 4 1 2 1 2 3 1 2 9 1 2 3 5 9 DE 42 0009 05/2013 Page 3/5 0 00 Feature Basic type P2.2 Amex 400l/h (Cl.I, Div.2 Gps. B,C,D. T3/T4) P2.4 Amex 400l/h (Cl.I, Div.2 Gps. B,C,D. T3/T4) P2.82 Amex 800l/h (Cl.I, Div.2 Gps. B,C,D. T3/T4) P2.84 Amex 800l/h (Cl.I, Div.2 Gps. B,C,D. T3/T4) Motor supply 230 V 50 Hz. 0,88 A 230 V 60 Hz. 0,89 A 115 V 50 Hz. 1,76 A 115 V 60 Hz. 1,78 A Pump head position Normal pos. Vertical Pointing downwards * Pump head material PTFE SS 1.4571 PTFE with bypass valve * Valve material to 100 °C PTFE/PVDF ** to 140 °C PTFE/PEEK Male stud couplings (depending on pump head) PTFE pump head Stainless steel pump head 1/4”-1/6” (standard) 1/4” (standard) DN 6/8 8 mm 3/8” 3/8"-1/4” 1/4"-1/8" 6 mm DN 4/6 Mounting accessories including mounting console and buffer * *not possible for P2.4 Amex and P2.84 Amex **not possible for P2.4 Amex, P2.82 Amex and P2.84 Amex Please keep in mind the required protection device for the pump’s motor! Motor protection switches - For mounting outside of hazardous area 230 V; 380-400 V, 0-1 A 9132020021 115 V, 1.6-2.5 A 9132020030 - For mounting inside of zone 1 or 2 (ATEX only) 230 V; 380-400 V, 0-1 A 9132020036 115 V, 1.6-2.5 A 9132020033 Hints for variations: Position of pump head: (P2.2 and P2.82 types only): If the gas contains entrained liquids, the pump head must point downwards. Although the pump head may be turned by the customer as described in the manual, we suggest ordering it in the required configuration. Pump head material: The standard material is PTFE. This can be equipped with a bypass valve to reach all the operation points in the grey area in the flow curve of the pump head (P2.2 and P2.82 types only). Depending on the tubing requirements, a stainless steel body may be ordered (bypass valve not available). Valve material: (P2.2 Atex and P2.82 Amex types only) For standard non-heated applications with sample temperatures up to 100 °C (212 °F), the PTFE/PVDF valves are sufficient. For higher temperatures, the valves for temperatures up to 140 °C (284 °F) are required. Please note that maximum temperatures may be limited for certain temperature classes (see the tables on page 2). DE 42 0009 05/2013 Page 4/5 Dimensions of P 2.2 ATEX, P 2.2 AMEX, P 2.82 AMEX - Drawing 1 24 view with rotated pump head M20x1,5 console 81 63 8 A 130 277,5 155,5 186 207 BÜHLER 100 125 205 220 M6 80 273,5 302 104 View “A” 18 130 adjustable bypass valve optional 100 Ø7 100 BÜHLER 130 Dimensions of P 2.4 ATEX, P 2.4 AMEX, P 2.84 AMEX - Drawing 2 39,5 107,5 24 A000115X ca.145 Wall max.30 M20x1,5 M6 8 63 196,5 155,5 186 207 BÜHLER 116 Ø7 80 85 100 125 89,5 205 220 254,5 370,5 ° DE 42 0009 05/2013 Page 5/5 ø94 ø110 ø7 Mounting Hints 1) Direction of the inlet/outlet connections can be chosen while mounting 2) If the gas carries condensate, the inlet/outlet connections must point downwards chest view 30° 60 We reserve the right to amend specification
© Copyright 2024