CT1/CS Series INSTRUCTION MANUAL CT1/CS Series INSTRUCTION MANUAL Customer Service 5. Connection to counters Model : CT1 · CS 37-7 Chuo-cho, 2-Chome Meguro-ku, Tokyo 152-0001 Japan Tel: +81-3-37165151 Fax: +81-3-37104552 webtrade@line.co.jp http://www.lineseiki.com AC power source Model : CT1-R (4P connector) Terminal numbers in generator's connector A Output B GND C DC power source Model : CT1 1. Models Reed switch 500meter [yard]/minute Weight 700g [25oz.] 710g [25oz.] 730g [26oz.] 730g [26oz.] 740g [26oz.] 790g [28oz.] 740g [26oz.] 740g [26oz.] 750g [26oz.] 780g [28oz.] Torque Model : CT1-R CT1-3:1R CT1-3:10R CT1-3:100R D COM Bidirectional Electronic Counter C Output A Output B 100[3.94] ±10[±0.39] 47[1.85] 4- ±0.5[±0.02] 5[0.20] 57[2.24] 130[5.12] Mounting Holes 25[0.98] 95[3.74]±0.5[±0.02] 105[4.13] Model : CT1-A 85.5[3.37] 7[0.28] N.O COM B A Output B GND C DC Power Source A B C D A C B DC Power Source Output A GND Output B 61[2.40] 5[0.20] Model : CS B CT1-A 68[2.68] 39[1.54] ] 30 [0. 7.5 Exploded view 4P connector D A C B COM GND D C CT1-R A B Meter Wheel Wheel UNIT OF MEASURE 38[1.50] A A B N.O Make sure that measuring wheels are fixed to shaft of the device with screws for avoiding slip. Make sure that measuring wheels are fixed with parallel and horizontal to measuring object or roller. In the case measuring object is possible to be stretched by tension, temperature and humidity, be careful with the surrounding condition when measuring. There may be some differences between measured value on the counter and actual length of the material. In the case, please confirm if measuring wheel slips or measuring roller does not synchronize with measuring object. ON and OFF ratio of output of standard device is 1:1. For example, 0.5m-ON and 0.5m-OFF are for the measuring unit of a meter. There may be some differences between measured value on the counter and actual length of the material. The difference may be created by the measuring "Start position" or the measuring "stop position" to be made shortly after or before ON/OFF of output has been made. In the case, it is recommended that you consider if the measuring unit is suitable to the measuring condition. 57[2.24] 130[5.12] 25[0.98] 95[3.74]±0.5[±0.02] 105[4.13] C 18[0.71] 8[0.31] • Model : CS (Reed switch output) D 4- 48[1.89] A C C B GND 47[1.85] 320[12.60]+20[+0.79] 3P connector 5-12VDC Lead Switch 47[1.85] 3- 6[0.24] Mounting Hole ±0.5[±0.02] 59[2.32] 134[5.28] 25[0.98] 59[2.32] 110[4.33] Meter Wheel Yard Wheel Meters Yards MODEL MRM096 MRM097 TYPE OF SURFACE Plain MATERIAL OF SURFACE Thermoplastic Rubber Yard Wheel 26[1.02] 18[0.71] ±0.5[±0.02] Mounting Holes Exploded view • Model : CT1-R (Photoelectronic sensor 2 outputs) 4P connector 7.5[0.30] 5[0.20] 2 pieces of measuring wheel for meter are equipped as standard accessories. Instead of those, 2 pieces of measuring wheel for yard are available. Please order type of measuring wheel. "-YP" should be added to the model number. (Ex.) CT1-3:10A-YP *3P/4P connector (Please wire the cables to the terminal pins inside the plug after removing the cover.) • Model : CT1-A (Photoelectronic sensor 1 output) 3P connector Output A Output Detection Circuit B GND 7.5[0.30] Measuring wheel for meter : Diameter 106.1mm (Circumstance 1/3 meter), Surface material is Thermoplastic Rubber. Measuring wheel for yard : Diameter 97.0mm (Circumstance 1/3 yard), Surface material is Thermoplastic Rubber. 4. Connection Output B C 2K Installation note 3. Accessories Measuring wheel for meter x 2 Measuring wheel for meter x 2, 3P connector x 1 Measuring wheel for meter x 2, 4P connector x 1 Measuring wheel for meter x 2 G10 G11 3 1 4 2 CS-3:1 5-24VDC Detection Circuit 30[1.18] Maximum load current 1 Output Reed switch Contact output, Capacity : 300VAC 0.7A 70VA, 350VDC 0.5A 50W (Load) -5 - +40°C [23 - 104°F] (Should not be Frozen) Ambient Humid. : Operating 85% max. (Non-Condensing) COM C GND 3.9K A Output A 19[0.75] Output impedance D CT1-3:1000A C 5-12VDC 32[1.26] Current consumption CS-3:1 N.O Detection Circuit 32[1.26] Power source 2K B 7[0.28] 1 Output Microswitch Contact output, Capacity : 250VAC · 5A , 125VDC 0.5A (Load) 1 Output 5-24VDC±10% 35mA 3.9K 100mA 1 Output 5-12VDC±10% 20mA 2K 20mA 2 Outputs( 90°Quadrature) 5-24VDC±10% 70mA 3.9K 100mA 2 Outputs( 90°Quadrature) 5-12VDC±10% 40mA 2K 20mA -10 - +50°C [14 - 122°F] (Should not be Frozen) Ambient Humid. : Operating 35 - 85% (Non-Condensing) Over-voltage category II, Pollution degree 2, Indoor use (IEC61010-1) Altitude 2000m max. Compliance CE, RoHS • Model : CT1 (Micro Switch output) 2K 85.5[3.37] 5[0.20] Output G60 G62 3 1 4 2 Model : CS CT1-3:1A CT1-3:10A CT1-3:100A Model : CT1 Electronic Counter Electromagnetic Counter CT1-3:1,CT1-3:10 CT1-3:1A,CT1-3:10A,CT1-3:100A CT1-3:1000A CT1-3:1R,CT1-3:10R,CT1-3:100R CT1-3:1000R Ambient temp. : Operating Installation environment Model : CT1 Model : CT1-A Model : CT1-R Model : CS A 5-24VDC Open collector output is available in 1 and 2 non-contact outputs models. "C" should be added to the model number. (Ex.) CT1-3:10AC Model G48 E48 3 1 4 2 7. Dimensions : mm [inch] 2. Specifications Ambient temp. : Operating A 3.9K B Detection Circuit Micro Switch 0.015N m (153gf-cm) [2.12ozf-in] 740g [26oz.] 3.9K N.O Electronic Counter 0.015N m [2.12ozf-in] MDR 3 4 6 5 Model : CT1-A CT1-3:1000R Proper Counter Electronic Counter Electromagnetic Counter 61[2.40] * Factory-installed option. : 1m[yard] Speed 240meter [yard]/minute 24meter [yard]/minute 700meter [yard]/minute 500meter [yard]/minute 250meter [yard]/minute 100meter [yard]/minute 700meter [yard]/minute 500meter [yard]/minute 250meter [yard]/minute 100meter [yard]/minute G10 G11 1 4 3 30[1.18] Unit G60 G62 1 4 3 20[0.79] Sensor G48 E48 1 4 3 Terminal numbers in generator's connector A DC power source B Output A C GND D Output B 6. Output circuit CT1-3:1 CT1-3:10 CT1-3:1 1m [yard] Microswitch CT1-3:10 0.1m [yard] CT1-3:1A 1m [yard] Photoelectronic Sensor, CT1-3:10A 0.1m [yard] 1 non-contact output CT1-3:100A 0.01m [yard] CT1-3:1000A 0.001m [yard] CT1-3:1R 1m [yard] Photoelectronic Sensor, CT1-3:10R 0.1m [yard] 2 non-contact outputs CT1-3:100R ( 90°Quadrature Output ) 0.01m [yard] CT1-3:1000R 0.001m [yard] MD 4 3 2 It is recommendable to use such components as diode, CR etc., for the protection of contact in the case of connection with such inductive load as electromagnetic counter. Terminal numbers in counter Terminal numbers in counter • Do not use this device near machines that emit strong electromagnetic fields or objects that store static electricity. • Do not drop or subject this device to strong impact. • Do not use this device on rollers with high temperature or where it will be exposed to solvent, oil and water. • Do not use or store this device where it will be exposed to direct sunlight, dust, high temperature and high humidity. • Do not use this device where it will be exposed to vibration to avoid incorrect measuring or fault. • Do not use organic solvents such as thinners etc. to clean this device. • Do not attempt to disassemble or modify this device. • Internal parts may be destroyed if a voltage outside the rated voltage is applied. • Do not touch the conductive part of leadwires while power is being applied. CS-3:1 DC power source Model : CT1-A (3P connector) Attention Model Electromagnetic Counters 26[1.02] 18[0.71] 7.5[0.3] Contact : E-mail : Web : Electromagnetic Counters 7.5[0.3] 97[38.2] +0.3[0.01] -0 Address: Misuse of this device may lead to injury to the user or damage to the device. WARNING LINE SEIKI CO., LTD. 106.1[4.18] +0.3[0.01] -0 Thank you for your purchasing our product. Please read this instruction manual carefully before using to ensure the correct usage of this product. Please keep this instruction manual for future reference. Rubber Wheels are subject to slip for wear in the long usage. It will cause measuring discrepancies. Please check the Wheels sometimes and exchange to new ones. This manual was last revised Mar. 31, 2014. 4CT001F *Subject to change without prior notice. All Rights Reserved,Copyright © 2014,LINE SEIKI CO.,LTD.
© Copyright 2024