SD-997B-1SQ Manual Mini Surface-Mount Deadbolt Mini Surface-Mount Deadbolt Manual

Mini Surface-Mount Deadbolt Manual
Troubleshooting:
Problem:
Possible cause:
Deadbolt does not activate
when the door closes.
The sensor in the lock body
is too far from the magnet in •Try adjusting the strike plate, lock body position, or shims.
the strike plate.
Deadbolt activates when the
door is closed, but does not
lock the door.
Deadbolt may not be properly •Make sure the deadbolt is going into the hole and not hitting
the strike plate. If not, you must reposition the strike plate.
going into the deadbolt hole
•If the deadbolt is going into the hole, it may be hitting the bottom of
in the door.
the hole (if it is in a wooden door). In this case, drill a deeper hole.
Solutions:
How to reset unit.
•Ground the green wire momentarily.
For any other problems
•Substitute a problem unit for a working unit in another door frame
to see if it works there.
SD-997B-1SQ
Mini Surface-Mount Deadbolt
Manual
Also Available from SECO-LARM:
Electric Deadbolt
Electric Shear Lock
SD-997B-GBQ
Fail-safe,
12/24 VDC operation.
With door-position
monitoring output.
SD-993B-SS
Holding force:
1,500lb (680kg).
Small size for use with
most metal door jambs.
Electromagnetic Locks
Universal Door Strike
Available with 80, 300,
SD-996C-NUQ
600, 1,200, or 1,300-lb
Field selectable fail-safe or
holding force. All locks come
fail-secure operation.
with a lifetime warranty.
UL listed.
WARRANTY: this SECO-LARM product is warranted against defects in material and workmanship while used in normal service
for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or
property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM
policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications
without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part,
without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
4
PITSW2
MiSD997B-1SQ_140506.indd
Website: www.seco-larm.com
E-mail: sales@seco-larm.com
SECO-LARM U.S.A., Inc.
• Fail-safe operation (unlocks if power is lost).
• Surface-mount design for easy installation.
• Magnetic switch senses door position for positive locking.
• Aluminum alloy bolt, 15/32”(12.7mm) diameter, 9/16”(14mm) throw.
• Automatically relocks after 6 seconds if the lock was unlocked but the door was
not opened.
• Door open/close monitor (NC/COM).
• Lock delay timer adjustable between 0 and 3 seconds.
• Use with an optional digital keypad for high security without a key.
•
Powered by a solenoid.
SECO-LARM
®
Mini Surface-Mount Deadbolt Manual
Mini Surface-Mount Deadbolt Manual
Introduction:
The SECO-LARM Mini Surface-Mount Electric Deadbolts is designed for hollow metal door frames and solid
wooden door frames. Its small size makes it easy to add secure, electrical locking to small doors.
Specifications:
Operation
Operation voltage
Current draw
Standby
Active
Status sensor
Adjustable lock delay timer
Operating Temperature
Weight
Parts List:
1x Lock body
1x Strike body
2x Plate spacer
Fail-safe
12VDC
237mA@12VDC max.
650mA@12VDC max.
250mA@30VDC (NC/COM)
0/3 s (default)
32°~158° F (0°~70° C)
1-lb,2.5-oz (450g)
a. Red – Power input (+)
b. Brown – Power input (-)
c. Green – Control wire (-) ground to release bolt
d. Blue – Door monitor, COM
e. Purple – Door monitor, N.C. (active when door closed)
Warning :
1. Correct polarity of the red and brown wires is critical. Incorrect polarity will burn out the
solenoid.
2. Do not connect a voltage input on the green wire otherwise it will damage the unit.
3. Maximum distance between lock body and strike body must not exceed 6mm.
Fig. 1 – Possible Mounting Locations.
1x 5-pin connector
6x Mounting screws (M4x40mm)
6x Screw cover stickers
Fig. 2 – Using the Plate Spacers
Plate spacer
Overview:
Lock body
Vertical mount
Lock body
Strike body
Plate spacer
Strike body
Horizontal mount
Fig. 3 – Adjusting the Lock Delay Time / Wire Output Direction.
Lock delay jumper
Jumper
Installation:
1.Determine where the deadbolt will be mounted (see fig. 1).
2. Adjust the wire output direction based on the selected application and adjust the lock delay time if necessary (see fig. 3).
Adjust the wire output direction
a. Unscrew the 2 screws and remove the cover of the lock body.
b. Remove the wire grommet from the lock body and insert the wires of the 5-pin connector into the grommet .
c. Plug the 5-pin male connector into the 5-pin socket and adjust the desired wire output direction as shown in fig. 3.
Adjust lock delay time
a. The default lock delay time is 3s. To remove the delay time, remove the jumper (see fig. 3).
3.Use the screw holes of the lock body and strike body as template and mark the locations of the screws with a pencil.
4.Secure the lock body and strike body with the 6 included screws. Use 4 screws for the lock body and 2 screws for the strike body. Cover the screw heads with the provided screw cover stickers.
Note: If there’s a gap betweent the lock body and the strike body, use the included 2 plate spacers to correct the alignment as shown in fig. 2.
5. Connect the wires and insulate them (see fig. 4):
Fig. 4 –Wiring Diagram
2
SECO-LARM U.S.A., Inc.
SECO-LARM U.S.A., Inc.
Delay Time
ON
3s (default)
OFF
0s
Adjust wire grommet for
different wire output direction
5-Pin Socket
5-Pin Connector
N.C.
N.O.
Card reader
COM or keypad
Request-to-Exit
pushbutton
Green wire (Control wire)
Brown wire (-)
Red wire (+)
Purple wire (Door Monitor, N.C.) – active if door is locked
Blue wire (Door Monitor, COM) – manual lock/unlock
12VDC
Power
Supply
3