RS Product User's Manual Firmware 5.00 and up Last Update: April 29 2014 Visit www.zaber.com/wiki for more recent updates. Zaber Technologies Inc. #2 - 605 West Kent Ave. N. Vancouver, British Columbia Canada, V6P 6T7 Table of Contents Disclaimer...........................................................................................................................................................1 Precautions.........................................................................................................................................................2 Installation..........................................................................................................................................................3 Operation............................................................................................................................................................4 Pin-Out for Minidin 8 (T-MCA connector and MC06 cable to Peripheral)...........................................4 Warranty and Repair........................................................................................................................................5 Standard products....................................................................................................................................5 Custom products.....................................................................................................................................5 How to return products...........................................................................................................................5 Email Updates....................................................................................................................................................6 Contact Information..........................................................................................................................................7 Group Specifications - RS Series.............................................................................................................8 Comparison - RS Series...........................................................................................................................9 i Disclaimer Zaber’s devices are not intended for use in any critical medical, aviation, or military applications or situations where a product's use or failure could cause personal injury, death, or damage to property. Zaber disclaims any and all liability for injury or other damages resulting from the use of our products. Disclaimer 1 Precautions Zaber’s rotary motion control devices are precision instruments and must be handled with care. In particular, moving parts must be treated with care. Avoid torque loads in excess of the rated maximum torque load, impact, dust and other contaminants and damage to the worm and worm gear. These will reduce the performance of the device below stated specifications. Precautions 2 Installation You can mount the RS series rotary stage by the three M6 or 1/4"x20 mounting holes on the bottom flange of the stage. There are also two M6 threaded holes on the sides of the stage available for mounting purposes. See the RS web page for dimensions, technical specifications and other details. Installation 3 Operation The RS rotary stages are designed to be controlled with the T-MCA series chopper drive controllers. It is important to know the peripheral id of your RS stage. If you ever need to restore the correct settings for your stage, send restore settings (command 36) with the peripheral ID as the data. Pin-Out for Minidin 8 (T-MCA connector and MC06 cable to Peripheral) Minidin 8 Female (on T-MCA) Minidin 8 Male (on Peripheral) Pin # 1 2 3 4 5 6 7 8 Function Motor A1 Motor A2 Motor B1 Not Connected Motor B2 +5V Home Signal Ground Operation 4 Warranty and Repair For Zaber's policies on warranty and repair, please refer to the Ordering Polices Standard products Standard products are any part numbers that do not contain the suffix ENG followed by a 4 digit number. Most, but not all, standard products are listed for sale on our website. All standard Zaber products are backed by a one-month satisfaction guarantee. If you are not satisfied with your purchase, we will refund your payment minus any shipping charges. Goods must be in brand new saleable condition with no marks. Zaber products are guaranteed for one year. During this period Zaber will repair any products with faults due to manufacturing defects, free of charge. Custom products Custom products are any part numbers containing the suffix ENG followed by a 4 digit number. Each of these products has been designed for a custom application for a particular customer. Custom products are guaranteed for one year, unless explicitly stated otherwise. During this period Zaber will repair any products with faults due to manufacturing defects, free of charge. How to return products Customers with devices in need of return or repair should contact Zaber to obtain an RMA form which must be filled out and sent back to us to receive an RMA number. The RMA form contains instructions for packing and returning the device. The specified RMA number must be included on the shipment to ensure timely processing. Warranty and Repair 5 Email Updates If you would like to receive our periodic email newsletter including product updates and promotions, please sign up online at www.zaber.com (news section). Newsletters typically include a promotional offer worth at least $100. Email Updates 6 Contact Information Contact Zaber Technologies Inc by any of the following methods: Phone 1-604-569-3780 (direct) 1-888-276-8033 (toll free in North America) Fax 1-604-648-8033 Mail #2 - 605 West Kent Ave. N., Vancouver, British Columbia, Canada, V6P 6T7 Web www.zaber.com Email Please visit our website for up to date email contact information. Contact Information 7 Group Specifications - RS Series Specification Integrated Controller Recommended Controller Range Accuracy (unidirectional) Repeatability Backlash Encoder Type Maximum Centered Load Maximum Cantilever Load Guide Type Stage Diameter Motor Type Motor Rated Current Motor Winding Resistance Inductance Motor Rated Power Motor Connection Mechanical Drive System Limit or Home Sensing Operating Temperature Range RoHS Compliant CE Compliant Weight Value No T-MCA (48 V) Recommended 360 degrees 0.1 degrees < .02 degrees < 0.06 degrees None 200 N 410 N-cm Pre-loaded ball bearing 60 mm Stepper (2 phase) 1500 mA/phase 2.05 ohms/phase 1 mH 9.2 Watts Minidin 8 male Precision Worm Gear Magnetic home sensor 0-50 degrees C Yes Yes 0.55 kg Group Specifications - RS Series Alternate Unit 1.745000 mrad < 0.349 mrad < 1.047 mrad 44.9 lb 580.6 oz-in 2.362 " 8 Comparison - RS Series Maximum Continuous Part Microstep Size (Default Maximum Speed Minimum Speed Torque Number Resolution) RS60A 0.000234375 degrees ( 4.091 urad) 70.3 deg/s ( 11.7 rpm) 0.0011 deg/s ( 19.198 urad/s) 80 N-cm ( 113.3 oz-in) RS60C 0.0009375 degrees ( 16.362 urad) 280 deg/s ( 46.7 rpm) 0.0044 deg/s ( 76.793 urad/s) 74 N-cm ( 104.8 oz-in) Comparison - RS Series 9
© Copyright 2024