L EASY Starter OPC UA Server Ä.O57ä

Engineering tools
EASY Starter
OPC UA Server
13462022
Ä.O57ä
Preparing OPC UA access to Lenze devices
Software Manual
EN
L
Contents
________________________________________________________________
1
1.1
About this documentation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Document history _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3
3
2
2.1
What is OPC UA? _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
OPC UA in the »EASY Starter« _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4
4
3
3.1
3.2
3.3
Access to Lenze devices with OPC UA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
»EASY Starter«: Using OPC UA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Starting the Lenze OPC UA server _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Lenze OPC UA server: options _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5
5
6
6
Your opinion is important to us _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8
2
Lenze · EASY Starter | OPC UA-Server · 1.0 EN - 04/2014
About this documentation
Document history
________________________________________________________________
1
About this documentation
This documentation contains information on how the access to Lenze devices via OPC UA is to be
prepared in the Lenze »EASY Starter«. The aim is to subsequently access Lenze devices with software
of different manufacturers in order to read and write device parameters.
1.1
Document history
Version
1.0
Description
04/2014
TD11 First edition
 Tip!
Current information on the Lenze products can be found at: http://www.Lenze.com
Lenze · EASY Starter | OPC UA-Server · 1.0 EN - 04/2014
3
What is OPC UA?
OPC UA in the »EASY Starter«
________________________________________________________________
2
What is OPC UA?
OPC Unified Architecture (OPC UA) is a standard of the OPC Foundation. OPC UA...
• ...allows for safe, reliable data transport between the field device level and manufacturerindependent software applications.
• ...allows to write/read the parameters of Lenze devices with software from different
manufacturers.
2.1
OPC UA in the »EASY Starter«
From version 1.6 on, the »EASY Starter« contains an OPC UA server with which the software of a
different manufacturer can access the parameters of the Lenze devices via the standardised OPC UA
interface in order to read/write values.
Advantages
The OPC UA standard has the following advantages:
• State of the art according to the OPC Foundation.
• On the OPC client side: access independent of the operating system; therefore remote access
possible with software which supports other operating systems than Microsoft Windows.
• Improved safety in remote maintenance with little configuration effort of the firewall settings
through coded communication and certificate verification.
Supported devices: which Lenze devices can I access?
Access is possible to all Lenze devices and communication links supported by the »EASY Starter«.
• The OPC UA server allows for the access to all current Lenze devices of the L-force product
portfolio.
• Furthermore access is possible to previous versions of the Global Drive series (8200, 9300, ECS).
The access to these devices was previously realised via "Drive Server" which has been replaced
by the newer OPC UA standard.
Supported software: which software allows the access?
The software with which you would like to access Lenze devices via OPC UA must act as OPC UA
client and support the OPC UA functionality.
4
Lenze · EASY Starter | OPC UA-Server · 1.0 EN - 04/2014
Access to Lenze devices with OPC UA
»EASY Starter«: Using OPC UA
________________________________________________________________
3
Access to Lenze devices with OPC UA

3.1
Note!
In order to access Lenze devices with OPC UA you need a valid licence in the "EASY
Advanced" version“ which is, for instance, included when buying the Lenze »Engineer«.
»EASY Starter«: Using OPC UA
The access to Lenze devices must first be prepared in the »EASY
Starter«. The button to prepare the access via OPC UA can only be
activated if...
...a licence of the "EASY Advanced" version or higher is available.
...at least one devices is integrated.
...the »EASY Starter« has been started in the parameterisation mode.
 How to proceed:
1. Start the »EASY Starter« in the parameterisation mode.
2. Add the required devices to the »EASY Starter« (area ),
3. Save the configuration by clicking the button (area ).
• The »EASY Starter« writes a configuration file, then the access to the Lenze devices is
prepared.
 Lenze devices which are to be accessed via OPC UA.
 Save the configuration file in order to prepare the access via OPC UA
Lenze · EASY Starter | OPC UA-Server · 1.0 EN - 04/2014
5
Access to Lenze devices with OPC UA
Starting the Lenze OPC UA server
________________________________________________________________
3.2
Starting the Lenze OPC UA server
After configuration the Lenze OPC UA server must be started: a link can be found in the Start Menu
of Windows: All programsLenzeOPC
 Tip!
When the Lenze OPC UA server has been started, the following symbol is visible in the
Microsoft Windows system tray:
When starting, the Lenze OPC UA server reads the file which was previously created in the »EASY
Starter«. »EASY Starter«: Using OPC UA ( 5)
3.3
Lenze OPC UA server: options
Normally no further settings are required. A context menu with additional options is available in the
system tray (tray icon):
Right-click on the symbol
Options:
• Close the Lenze OPC UA server.
• Have a logging file with error information output.
• Display information on the server (endpoint URL), administer certificates.
6
Lenze · EASY Starter | OPC UA-Server · 1.0 EN - 04/2014
Index
________________________________________________________________
C
Configuring the Lenze OPC UA server (optional) 6
O
OPC UA
Access to Lenze devices 5
OPC UA in the EASY Starter 4
S
Starting the Lenze OPC UA server 6
U
Using OPC UA 5
W
What is OPC UA? 4
Lenze · EASY Starter | OPC UA-Server · 1.0 EN - 04/2014
7
)(('%$&.
8
Your opinion is important to us
These instructions were created to the best of our knowledge
and belief to give you the best possible support for handling
our product.
If you have suggestions for improvement, please e-mail us to:
feedback-docu@Lenze.de
Thank you for your support.
Your Lenze documentation team
L
© 04/2014

Lenze Automation GmbH
Hans-Lenze-Str. 1
D-31855 Aerzen
Germany
Service
Lenze Service GmbH
Breslauer Straße 3
D-32699 Extertal
Germany

+49 (0)5154 – 82 -0

00 80 00 / 24 4 68 77 (24 h helpline)

+49 (0)5154 – 82 - 2800

+49 (0)51 54 / 82-11 12

Lenze@Lenze.de

Service@Lenze.de

www.Lenze.com
SHPEASYSTART  13462022  EN 1.0  TD11
10
9
8
7
6
5
4
3
2
1