HYGIENE AND DISINFECTION PROGRAM FOR DENTAL SUCTION SYSTEMS Product Puli-Jet Plus (New) Concentrated disinfectantdtergent for aspirators Puli-Jet Plus Concentrated disinfectantdetergent for aspirators Puli-Jet Classic Sanitizing detergent for aspirators Disinfectant antifoam tablets Disinfectant antifoam tablets for aspirators Sanitizing antifoam tablets Sanitizing antifoam tablets for aspiration Application When to use How to use Range of Action Single surgery and centralized aspiration systems At the end of the working day, after surgical interventions on high infection risk patients, for a detergent-disinfectant wash. For a cleaning-disinfectant action: prepare a solution at 0.8% in warm water (about 50C). For a cleaning -sanitizing action: prepare a solution on 0.4% in warm water (about 50C). Suck from the Pulse Cleaner through the equipment. With 1 litre of product it is possible to obtain 250 litres of sanitizing solution at 0.4% and 125 litres of disinfectant solution at 0.8%. Let it work during the night or for at least 1 hour. Detergent disinfectant: Single surgery and centralized aspiration systems. At the end of the working day, after surgical interventions on high infection risk patients, for a detergent-disinfectant wash. For a cleaning-disinfectant action: prepare a solution at 0.8% in warm water (about 50C). For a cleaning -sanitizing action: prepare a solution on 0.4% in warm water (about 50C). Suck from the Pulse Cleaner through the equipment. With 1 litre of product it is possible to obtain 250 litres of sanitizing solution at 0.4% and 125 litres of disinfectant solution at 0.8%. Let it work during the night or for at least 1 hour. Detergent disinfectant: Single surgery and centralized aspiration systems. Midworking day, after surgical interventions. for a detergent-sanitizing wash. Prepare a solution at 5% in warm water (about 50C). Suck from the Pulse Cleaner through the equipment. With 1 litre of Puli-Jet Classic it is possible to obtain 20 litres of solution at 5%. Detergent sanitizingantibacterial Single surgery and centralized aspiration systems. At the end of every working day, after cleaning and disinfection. At the end of every working day, after cleaning, place 1 or 2 tablets in the first filter: when aspirated, the liquid will take up the right quantity of product. Antifoam Disinfectant: Single surgery and centralized aspiration systems. At the end of every working day, after cleaning and disinfection. At the end of every working day, after cleaning, place 1 or 2 tablets in the first filter: when aspirated, the liquid will take up the right quantity of product. Antifoam Disinfectant: - Bactericide - Fungicide - Tuberculicide - Bactericide - Fungicide - Tuberculicide - Virucide - Bactericide - Candidicide - Bactericide - Candidicide Certificates and ref. rules CE 0434 Class 11a-Medical Device Precautions Use protective gloves when preparing the solution. UNI EN 13727:2004 UNI EN 13624:2004 PrEN 14563:2002 CE 0434 Class 11a-Medical Device Use protective gloves when preparing the solution. UNI EN 13727:2004 UNI EN 13624:2004 PrEN 14563:2005 UNI EN 14476:2007 Use protective gloves when preparing the solution. CE 0434 Class 11a-Medical Device UNI EN 13727:2004 UNI EN 13624:2004 Do not remove the protective film: it dissolves in the aspirated liquid. For small filters: remove the film, then break the tablet in half by pressing along the precut groove. Use protective gloves. Do not remove the protective film: it dissolves in the aspirated liquid. For small filters: remove the film, then break the tablet in half by pressing along the precut groove. Use protective gloves. APPLICATION OF THE CHEMICAL PRODUCTS FOR THE HYGIENE OF THE DENTAL SURGERY Product Fast & Sterile 3 High-Level Disinfectant / sterilizer for surgical impressions Fast & Sterile 3 Impressions High-Level disinfectant sterilizer for dental impressions Quick Sterile Chemical sterilizer for surgical instruments Quick Sterile Indicator Accessory to verify the MEC Eco-Jet 1 Tissue High-level disinfectant wet wipes Application Surgical instruments that cannto be treated with a thermo-disinfector On dental impressions prior to sending them to the laboratory Surgical instruments which cannot be sterilized thermally When to use On clean and dry surgical instruments On dental impressions just produced On clean and dry surgical instruments Quick sterile sterilizing solutions Before sterilizing treatments with Quick Sterile reused or freshly prepared solutions Flat and smooth surfaces, handles, etc After every intervention How to use Characteristics Pour the entire contents of all 3 packets into 2.5 litres of water. After 10 minutes submerge the instruments completely. - The solution remains active for a period of 36 hours Pour the entire contents of all 3 packets into 1 litre of water. After 10 minutes submerge the instruments completely for 10/15 minutes. - The solution remains active for a period of 36 hours Dilute at 1.5% (activity time: 8 hours) or 6% (activity time: 4 hours). Dip the instruments completely. Aspirate the fixed quantity of liquid into the syringe, then compare the colour of the liquid. - Handy - Rapid - Cheap - Wipe clean with a gentle pressure the surface to be treated. CE 0434 - Bactericide within 10’ - Fungicide within 10’ - Tuberculocide within 15’ - Virucide within 10’ - Sporicidal within 15’ CE 0434 - Non-corrosivity Diluted at 6%: CE 0434 - Absence of harmful vapours - Bactericide within 5’ - Fungicide within 5’ - Tuberculocide within 5’ - Virucide within 5’ - Sporicidal within 4h UNI EN 13727, UNI EN 14561, UNI EN 13624, UNI EN 14562, UNI EN 14348, Pr EN 14563, UNI EN 14476, UNI EN 13704, AFNOR NF T 72-190 - Non-corrosive, nonstaining - Non-corrosive, nonstaining, it does not deform dental impressions based on alginates, polyester, silicone and elastomer High-level disinfectant -detergent Irregular, rough or difficult to reach sufaces After every intervention Ready-to-use: - Spray onto the surface from 20/30 cm Disinfectant for instruments after use AC Net Detergent for the cleaning of autoclave chambers Aqua Plus It prevents both biofilm growth and cross infections Lubri-Jet Spray Lubricant Lubri-Jet Drop Lubricant Protective Hand Cream UNI EN 14563, UNI EN 13704, UNI EN 1276, UNI EN 1650, UNI EN 14476 CE 0434 Detergent disinfectant: CE 0434 - Bactericide (within less than 5’) - Virucide (within less than 15’) - Fungicide (within less than 15’) - Tuberculocide (within less than 5’) UNI EN 1650, UNI EN 13713, UNI EN 14476, UNI EN 13697 (HIV, HBV, HCV), UNI EN 14348, Skin Patch Test Cool, flower-scented perfume. Detergent disinfectant: CE 0434 - Bactericide (within less than 5’) - Virucide (within less than 15’) - Fungicide (within less than 15’) - Tuberculocide (within less than 5’) UNI EN 1650, UNI EN 13713, UNI EN 14476, UNI EN 13697 (HIV, HBV, HCV), UNI EN 14348, Skin Patch Test - Non corrosive Diluted at 3%: CE 0434 - Absence of harmful vapours - Bactericide within 5’ - Fungicide within 10’ - Tuberculocide within 5’ - Virucide within 5’ UNI EN 13727, UNI EN 14561, UNI EN 13624, UNI EN 14562, UNI EN 14348, pr EN 14563, UNI EN 14476 - Bactericide within 10’ - Fungicide within 60’ - Tuberculocide within 10’ - Legionellicide within 5’ CE 0434 - Let it soak for 5 minutes - Wipe with a dry sterile cloth Eco-Jet 2 UNI EN 14563, UNI EN 13704, UNI EN 1276, UNI EN 1650, UNI EN 14476, UNI EN 13697 Cool, flower-scented perfume. It leaves no residue - Let it work for 5 minutes, self-drying Eco-Jet 1 Spray Certificates and ref. rules - Bactericide within 10’ - Fungicide within 10’ - Tuberculocide within 15’ - Virucide within 10’ - Sporicidal within 15’ - Rapid activity time (1/2 of the glutaraldehyde activity time) Ready-to-use: Range of Action Precautions We suggest to keep the disinfecting solution in a covered basin. After 2 days from the activation, the solution can be aspirated into the suction system. We suggest to keep the disinfecting solution in a covered basin. After 2 days from the activation, the solution can be aspirated into the suction system. Verify the minimum effective concentration (MEC). Wear gloves. Carry out preliminary test on the instruments. Wipe off any splashes immediately. Do not use after the expiry date. To be used with Quick Sterile only. It is generally safe on hands. It can be used without wearing gloves. It has been tested on many materials. As a precaution, we recommend carrying out a preliminary test on a part which is not in sight. It is generally safe on hands. It can be used without wearing gloves. It has been tested on many materials. As a precaution, we recommend carrying out a preliminary test on a part which is not in sight. Used instruments, before cleaning and sterilization cycle Immediately after use and before cleaning Dilute at 1.5% (activity time: 1h) or 3% (activity time: 5-10’). Dip the instruments completely. Stainless steel medical autoclaves When needed Spray onto the surface to be treated, wipe clean, rinse with water and dry. Dental unit water piping (DUW) - Between one treatment and the other - During the night, weekend, etc Diluted at 4%: Fill the water circuit with the solution and let it work for at least 5/10 minutes. Safe on DUWs materials Surfaces exposed to rubbing (rubber o-rings, forceps, scissors, etc) When needed. Before the thermal sterilization cycle, if required On clean and dry surfaces Spray version for the treatment of surfaces. Not flammable. Dust repellent. Avoid leaks and wipe off any excess. Surfaces exposed to rubbing (rubber o-rings, forceps, scissors, etc) When needed. Before the thermal sterilization cycle, if required On clean and dry surfaces Phial with reclosable drop dispenser. Avoid leaks and wipe off any excess. Do not spray near an open flame. Avoid inhaling and avoid eye area. Hands After every washing or in case of need. Apply a minimum quantity of cream (0.3g at a time), then rub in delicately until absorbed. It contains dermatophile oils which protect the skin from dehydration and reddening caused by frequent use of latex gloves. Rapidly absorbed. Do not use in excess. UNI EN 13727, UNI EN 13624, UNI EN 14348, Pr EN 13623 Wear gloves. Carry out a preliminary test on the instruments. Wipe off any splashes immediately. Check if the dental unit is fitted with an automatic disinfection system. For further information, please contact Cattani ESAM UK Limited, 21a Harris Business Park, Hanbury Road, Stoke Prior, Bromsgrove, Worcestershire, B60 4DJ E S A M U.K. LIMITED t: 01527 877997 f: 01527 839799 e: info@cattaniesam.co.uk w: www.cattaniesam.co.uk
© Copyright 2024