Sensor technologies ► Pressure sensors PM1 series Brochure 2 Sensor technologies ► Pressure sensors PM1 series Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable 3 Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable 8 Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable ► ATEX certified 13 Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable ► ATEX certified 18 Pressure Switches, Series PM1 ► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air connection: CNOMO ► Spring-loaded bellow, non-adjustable 21 Connecting cable, Series CN2 ► Socket, M12, 5-pin, A-coded ► without wire end ferrule, tin-plated, 4-pin 24 Electrical connectors, Series CN1 ► ISO 4400 ► Electrical connector, form A ► 18 mm 25 Accessories Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 3 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable 21212 Measurement Relative pressure Switching element microswitch (input/output) Switching frequency 1,5 Hz Protection against overpressure 80 bar Ambient temperature min./max. -20°C / +80°C Medium temperature min./max. -10°C / +80°C Medium Compressed air hydraulic oil Shock resistance max. (XYZ direction) 15 g Vibration resistance (XYZ direction) 10 g (60 - 500 Hz) Switching point adjustable Hysteresis max. switching pressure difference DC operating voltage min./max. 12 V - 125 V Operational voltage AC min./max. 12 V - 250 V Mounting orientation Any Mounting types via through holes Function change-over contact (mechanical) Protection class IP65 Weight 0.16 kg Materials: Housing Aluminum Seals Acrylonitrile Butadiene Rubber Bellow Brass Electr. connection Brass, nickel-plated Technical Remarks ■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2. ■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching! ■ The microswitch has silver-plated contacts. Type Operating pressure range min./max. Compressed air connection Repeatability (% of full scale value) Fig. Note Part No. 2) R412010711 1); 3) R412010712 1); 2) R412010713 2) R412010714 1); 3) R412010715 1); 2) R412010718 [bar] PM1-M3-G014 -0.9 / 0 internal thread, G 1/4 ±1% Fig. 1 PM1-M3-G014 0.2 / 16 internal thread, G 1/4 ±1% Fig. 1 PM1-M3-F001 -0.9 / 0 Flange with O-ring, Ø 5x1,5 ±1% Fig. 2 PM1-M3-F001 0.2 / 16 Flange with O-ring, Ø 5x1,5 ±1% Fig. 2 1) Min. switching pressure range 0.2 bar falling/0.5 bar rising 2) Scope of delivery: with electrical connector 3) Scope of delivery: without electrical connector Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 4 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable Fig. 1 73 9 15 Ø9 5,3 ~ 81 M16x1,5 5 20 G1/4 30 30 43,5 2 ~ 80 17184 1) Electrical connector 2) Adjustment screw, self-holding Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 5 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable Fig. 2 68 4) Ø9 10 5,3 ~ 76 M16x1,5 5 20 5 30 30 43,5 3) 2 ~ 80 17185 1) Electrical connector 2) Adjustment screw, self-holding 3) cylinder screw M5x30 (included in scope of delivery) 4) O-ring Ø5x1,5 (included) PIN assignment for electrical connector 4) 1) 2) 3) 17186 1) +UB 2) break contact 3) make contact 4) GND Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 6 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable differential switching pressure characteristic curve (-0,9 – 0 bar) p1(+) bar +0,2 +0,1 0 -0,1 -0,2 -0,3 -0,4 -0,5 -0,6 -0,7 -0,8 -0,9 -1,0 -1,0 -0,8 -0,7 -0,6 -0,5 -0,4 -0,3 -0,2 A) B) 0 p1(-) bar 17187 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 7 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable differential switching pressure characteristic curve (0,2 ‒ 16 bar) p1(+) bar 16 15 14 13 12 11 10 9 p1 8 7 6 5 4 3 2 1 0 0 2 4 6 8 A) 10 12 14 B) 16 p1(-) bar 17188 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8 bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar max. permissible continuous current I max. [A] with ohmic load U [V] 30 48 60 125 250 I [A] 2) 3 1,2 0,8 0,4 – I [A] 1) 5 5 5 5 5 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC max. permissible continuous current I max. [A] with inductive load U [V] 30 48 60 125 250 I [A] 2) 4) 2 0.55 0.4 0.15 – I [A] 1) 3) 3 3 3 3 3 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC 3) cos ≈ 0,7° 4) L/R ≈ 10 ms Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 8 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable 18043 Measurement Relative pressure Switching element microswitch (input/output) Switching frequency 1,5 Hz Protection against overpressure 80 bar Ambient temperature min./max. -20°C / +80°C Medium temperature min./max. -10°C / +80°C Medium Compressed air hydraulic oil Shock resistance max. (XYZ direction) 15 g Vibration resistance (XYZ direction) 10 g (60 - 500 Hz) Switching point adjustable Hysteresis max. switching pressure difference DC operating voltage min./max. 12 V - 30 V Operational voltage AC min./max. 12 V - 30 V Mounting orientation Any Mounting types via through holes Function change-over contact (mechanical) Protection class IP67 Weight 0.15 kg Materials: Housing Aluminum Seals Acrylonitrile Butadiene Rubber Bellow Brass Electr. connection Brass, nickel-plated Technical Remarks ■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2. ■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching! ■ The microswitch has silver-plated contacts. Type Operating pressure range min./max. Compressed air connection Repeatability (% of full scale value) Fig. Note Part No. [bar] PM1-M3-G014 -0.9 / 0 internal thread, G 1/4 ±1% Fig. 1 - R412010716 PM1-M3-G014 0.2 / 16 internal thread, G 1/4 ±1% Fig. 1 1) R412010717 PM1-M3-F001 -0.9 / 0 Flange with O-ring, Ø 5x1,5 ±1% Fig. 2 - R412010719 PM1-M3-F001 0.2 / 16 Flange with O-ring, Ø 5x1,5 ±1% Fig. 2 1) R412010720 1) Min. switching pressure range 0.2 bar falling/0.5 bar rising Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 9 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable Fig. 1 9 Ø9 15 5,3 73 M12x1 2 5 20 G1/4 30 30 43,5 2 ~ 59 17189 1) Adjustment screw, self-holding 2) Detent position Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 10 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable Fig. 2 68 M12x1 4) Ø9 10 5,3 3) 5 20 5 2) 30 30 43,5 2 ~ 59 17190 1) Adjustment screw, self-holding 2) cylinder screw M5x30 (included in scope of delivery) 3) O-ring Ø5x1,5 (included) 4) Detent position Pin assignments 2) 3) 1) 4) 00127752 1) +UB 2) break contact 3) No function 4) make contact Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 11 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable differential switching pressure characteristic curve (-0,9 – 0 bar) p1(+) bar +0,2 +0,1 0 -0,1 -0,2 -0,3 -0,4 -0,5 -0,6 -0,7 -0,8 -0,9 -1,0 -1,0 -0,8 -0,7 -0,6 -0,5 -0,4 -0,3 -0,2 A) B) 0 p1(-) bar 17187 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 12 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable differential switching pressure characteristic curve (0,2 ‒ 16 bar) p1(+) bar 16 15 14 13 12 11 10 9 p1 8 7 6 5 4 3 2 1 0 0 2 4 6 A) 8 10 12 14 B) 16 p1(-) bar 17188 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8 bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar max. permissible continuous current I max. [A] with ohmic load U [V] 30 I [A] 2) 3 I [A] 1) 4 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC max. permissible continuous current I max. [A] with inductive load U [V] 30 I [A] 2) 4) 2 I [A] 1) 3) 3 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC 3) cos ≈ 0,7° 4) L/R ≈ 10 ms Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 13 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable ► ATEX certified 21212 ATEX II 3G Ex nAC IIC T6 X II 3D Ex tD A22 IP65 T 80° C X Measurement Relative pressure Switching element microswitch (input/output) Switching frequency 1,5 Hz Protection against overpressure 80 bar Ambient temperature min./max. +0°C / +80°C Medium temperature min./max. +0°C / +80°C Medium Compressed air hydraulic oil Shock resistance max. (XYZ direction) 15 g Vibration resistance (XYZ direction) 10 g (60 - 500 Hz) Switching point adjustable Hysteresis max. switching pressure difference DC operating voltage min./max. 12 V - 125 V Operational voltage AC min./max. 12 V - 250 V Mounting orientation Any Mounting types via through holes Function change-over contact (mechanical) Protection class IP65 Weight 0.16 kg Materials: Housing Aluminum Seals Acrylonitrile Butadiene Rubber Bellow Brass Electr. connection Brass, nickel-plated Technical Remarks ■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2. ■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching! ■ The microswitch has silver-plated contacts. Type Operating pressure range min./max. PM1-M3-G014 -0.9 / 1 internal thread, G 1/4 PM1-M3-G014 0.2 / 16 internal thread, G 1/4 0.2 / 16 Flange with O-ring, Ø 5x1,5 PM1-M3-F001 [bar] Compressed air connection Repeatability (% of full scale value) ±1% Fig. Note Part No. Fig. 1 - R412010727 Fig. 1 1) R412010728 Fig. 2 1) R412010729 1) Min. switching pressure range 0.2 bar falling/0.5 bar rising Delivery contents: including electrical connector Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 14 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable ► ATEX certified Fig. 1 73 9 15 Ø9 5,3 ~ 81 M16x1,5 5 20 G1/4 30 30 43,5 2 ~ 80 17208 1) Electrical connector 2) Adjustment screw, self-holding Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 15 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable ► ATEX certified Fig. 2 68 4) Ø9 10 5,3 ~ 76 M16x1,5 5 20 5 30 30 43,5 3) 2 ~ 80 17209 1) Electrical connector 2) Adjustment screw, self-holding 3) cylinder screw M5x30 (included in scope of delivery) 4) O-ring Ø5x1,5 (included) PIN assignment for electrical connector 4) 1) 2) 3) 17186 1) +UB 2) break contact 3) make contact 4) GND Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 16 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable ► ATEX certified differential switching pressure characteristic curve (-0,9 – 1 bar) P1 (+) bar +1,2 +1,1 +1,0 1) +0,9 2) +0,8 +0,7 +0,6 +0,5 +0,4 +0,3 +0,3 +0,1 P1 (-) bar P1 (+) bar -0,1 -0,2 -0,3 -0,4 -0,5 -0,6 -0,7 -0,8 -0,9 -1,0 -1,0 -0,8 -0,6 -0,4 -0,2 P1 (-) bar +0,2 +0,4 +0,6 +0,8 +1,0 17210 1) Rising 2) Falling p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 17 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded bellow, adjustable ► ATEX certified differential switching pressure characteristic curve (0,2 ‒ 16 bar) p1(+) bar 16 15 14 13 12 11 10 9 p1 8 7 6 5 4 3 2 1 0 0 2 4 6 8 A) 10 12 14 B) 16 p1(-) bar 17188 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8 bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar max. permissible continuous current I max. [A] with ohmic load U [V] 30 48 60 125 250 I [A] 2) 3 1,2 0,8 0,4 – I [A] 1) 5 5 5 5 5 1) AC 2) DC max. permissible continuous current I max. [A] with inductive load U [V] 30 48 60 125 250 I [A] 2) 4) 2 0.55 0.4 0.15 – I [A] 1) 3) 3 3 3 3 3 1) AC 2) DC 3) cos ≈ 0,7° 4) L/R ≈ 10 ms Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 18 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable ► ATEX certified 17211 ATEX II 3G Ex nAC IIC T6 X II 3D Ex tD A22 IP67 T 80° C X Measurement Relative pressure Switching element microswitch (input/output) Switching frequency 1,5 Hz Protection against overpressure 80 bar Ambient temperature min./max. +0°C / +80°C Medium temperature min./max. +0°C / +80°C Medium Compressed air hydraulic oil Shock resistance max. (XYZ direction) 15 g Vibration resistance (XYZ direction) 10 g (60 - 500 Hz) Switching point adjustable Hysteresis max. switching pressure difference DC operating voltage min./max. 12 V - 30 V Operational voltage AC min./max. 12 V - 30 V Mounting orientation Any Mounting types via through holes Function change-over contact (mechanical) Protection class IP67 Weight 0.16 kg Materials: Housing Aluminum Seals Acrylonitrile Butadiene Rubber Bellow Brass Electr. connection Brass, nickel-plated Technical Remarks ■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2. ■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching! ■ The microswitch has silver-plated contacts. Type Operating pressure range min./max. Compressed air connection Repeatability (% of full scale value) Fig. Note Part No. internal thread, G 1/4 ±1% Fig. 1 - R412010730 [bar] PM1-M3-G014 -0.9 / 1 PM1-M3-G014 PM1-M3-F001 internal thread, G 1/4 0.2 / 16 Flange with O-ring, Ø 5x1,5 Fig. 1 ±1% Fig. 2 R412010731 1) R412010732 1) Min. switching pressure range 0.2 bar falling/0.5 bar rising Delivery contents: including electrical connector and cable (5 m) Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 19 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable ► ATEX certified Pin assignment M12x1 2) 3) 1) 4) 00127752 1) +UB 2) break contact 3) No function 4) make contact differential switching pressure characteristic curve (-0,9 – 1 bar) P1 (+) bar +1,2 +1,1 +1,0 1) +0,9 2) +0,8 +0,7 +0,6 +0,5 +0,4 +0,3 +0,3 +0,1 P1 (-) bar P1 (+) bar -0,1 -0,2 -0,3 -0,4 -0,5 -0,6 -0,7 -0,8 -0,9 -1,0 -1,0 -0,8 -0,6 -0,4 -0,2 P1 (-) bar +0,2 +0,4 +0,6 +0,8 +1,0 17210 1) Rising 2) Falling p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 20 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow, adjustable ► ATEX certified differential switching pressure characteristic curve (0,2 ‒ 16 bar) p1(+) bar 16 15 14 13 12 11 10 9 p1 8 7 6 5 4 3 2 1 0 0 2 4 6 A) 8 10 12 14 B) 16 p1(-) bar 17188 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure Δ p1 = max. operating pressure difference or hysteresis Example: p1 (+) = 8 bar > p1(-) = 7.6 bar Δ p1 = 0.4 bar max. permissible continuous current I max. [A] with ohmic load U [V] 30 I [A] 2) 3 I [A] 1) 4 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC max. permissible continuous current I max. [A] with inductive load U [V] 30 I [A] 2) 4) 2 I [A] 1) 3) 3 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC 3) cos ≈ 0,7° 4) L/R ≈ 10 ms Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 21 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air connection: CNOMO ► Spring-loaded bellow, non-adjustable 18832 Measurement Relative pressure Switching element microswitch (input/output) Switching frequency 1,5 Hz Protection against overpressure 80 bar Ambient temperature min./max. -20°C / +80°C Medium temperature min./max. -10°C / +80°C Medium Compressed air hydraulic oil Shock resistance max. (XYZ direction) 15 g Vibration resistance (XYZ direction) 10 g (60 - 500 Hz) Repeatability (% of full scale value) ±1% Switching point adjustable Hysteresis max. switching pressure difference DC operating voltage min./max. 12 V - 30 V Operational voltage AC min./max. 12 V - 250 V DC switching current, max.[A] 3 Mounting orientation Any Mounting types via through holes Function change-over contact (mechanical) Protection class IP65 Weight 0.16 kg Materials: Housing Aluminum Bellow Brass Electr. connection Brass, nickel-plated Technical Remarks ■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2. ■ Set to 1.5 bar operating pressure. Adjustment screw secured and covered by an adhesive label. ■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching! ■ The microswitch has silver-plated contacts. Type Operating pressure range min./max. Part No. [bar] PM1-M3-F001 0.2 / 16 Min. switching pressure range 0.2 bar falling/0.5 bar rising Scope of delivery: without electrical connector Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change R412010721 22 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air connection: CNOMO ► Spring-loaded bellow, non-adjustable Ø8 1,5 4,2 3,8 10 68 Dimensions 5 4,5 30 21 43,5 30 17192 PIN assignment for electrical connector 4) 1) 2) 3) 17186 1) +UB electric for 12-24 V DC, break contact 3) make contact 4) GND Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 23 Sensor technologies ► Pressure sensors Pressure Switches, Series PM1 ► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air connection: CNOMO ► Spring-loaded bellow, non-adjustable differential switching pressure characteristic curve (0,2 ‒ 16 bar) p1(+) bar 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 2 4 6 8 A) 10 12 14 B) 16 p1(-) bar 17193 A) p1 (-), min. B) p1 (-), max. p1 (+) = upper switching pressure with increasing pressure p1 (-) = lower switching pressure with decreasing pressure max. permissible continuous current I max. [A] with ohmic load U [V] 30 48 60 125 250 I [A] 2) 3 1,2 0,8 0,4 – I [A] 1) 5 5 5 5 5 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC max. permissible continuous current I max. [A] with inductive load U [V] 30 48 60 125 250 I [A] 2) 4) 2 0.55 0.4 0.15 – I [A] 1) 3) 3 3 3 3 3 reference cycle: 30/min., reference temperature: +30°C 1) AC 2) DC 3) cos ≈ 0,7° 4) L/R ≈ 10 ms Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 24 Sensor technologies ► Pressure sensors Series PM1 Accessories Connecting cable, Series CN2 ► Socket, M12, 5-pin, A-coded ► without wire end ferrule, tin-plated, 4-pin Ambient temperature min./max. -40°C / +85°C Protection class IP65 Materials: Cable sheath Polyurethane 00107009_c Technical Remarks ■ The specified protection class is valid only in assembled and tested state. -20% / +20% max. [V DC] 300 [V AC] 250 Max. current Number of wires [A] 4 4 Wire cross-section [mm²] 0.34 Cable exit angled 90° Cable length L Weight [m] [kg] Part No. 3 0.13 1834484259 5 0.202 1834484260 10 0.387 1834484261 Dimensions 00107205_b (1) BN=brown (2) WH=white (3) BU=blue (4) BK=black (5) not assigned L = length Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change 25 Sensor technologies ► Pressure sensors Series PM1 Accessories Electrical connectors, Series CN1 ► ISO 4400 ► Electrical connector, form A ► 18 mm Ambient temperature min./max. -40°C / +90°C Protection class IP65 mounting screw tightening torque 0.4 Nm 00110264_a Technical Remarks ■ The specified protection class is valid only in assembled and tested state. Cable fitting 1 2 3 -20% / +20% DC [V] Max. current Contact assignment Cable exit suitable cable-Ø min./max M16x1,5 300 10 3+E angled 90° 6/8 1834484059 M20x1,5 24 8 3+E angled 90° 4.5 / 11 8941012462 [A] Part No. [mm] 1 2 3 gn/ge 1 2 3 4 1 2 3 Part No. number of plug options 1 Status display LED status display Housing color 1834484059 4 positions each 90° - - Black 8941012462 1 position 2 LED GreenRed Transparent 1) electrical connector with status display (2 LED) for pressure sensor 2) Profile seal 3) Flat gasket 4) Housing: Polyamide Seal: caoutchouc/butadiene caoutchouc Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change Weight [kg] Note 0.03 2) 0.03 1); 2); 4) 26 Sensor technologies ► Pressure sensors Series PM1 Accessories Dimensions 00110274 1) Max. Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change Aventics GmbH Ulmer Straße 4 30880 Laatzen Phone +49 511 2136-0 Fax +49 511 2136-269 www.aventics.com info@aventics.com Find more contact information at www.aventics.com/contact Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer’s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging. 14-10-2014 An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. © AVENTICS S.à.r.l.. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.a.r.l.. It may not be reproduced or given to third parties without its consent. PDF online
© Copyright 2024