PM1 series Sensor technologies ► Pressure sensors Brochure

Sensor technologies ► Pressure sensors
PM1 series
Brochure
2
Sensor technologies ► Pressure sensors
PM1 series
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400,
form A ► Spring-loaded bellow, adjustable
3
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1
► Spring-loaded bellow, adjustable
8
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400,
form A ► Spring-loaded bellow, adjustable ► ATEX certified
13
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1
► Spring-loaded bellow, adjustable ► ATEX certified
18
Pressure Switches, Series PM1
► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400,
form A ► Compressed air connection: CNOMO ► Spring-loaded bellow, non-adjustable
21
Connecting cable, Series CN2
► Socket, M12, 5-pin, A-coded ► without wire end ferrule, tin-plated, 4-pin
24
Electrical connectors, Series CN1
► ISO 4400 ► Electrical connector, form A ► 18 mm
25
Accessories Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
3
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable
21212
Measurement
Relative pressure
Switching element
microswitch (input/output)
Switching frequency
1,5 Hz
Protection against overpressure
80 bar
Ambient temperature min./max.
-20°C / +80°C
Medium temperature min./max.
-10°C / +80°C
Medium
Compressed air
hydraulic oil
Shock resistance max.
(XYZ direction)
15 g
Vibration resistance
(XYZ direction)
10 g (60 - 500 Hz)
Switching point
adjustable
Hysteresis
max. switching pressure difference
DC operating voltage min./max.
12 V - 125 V
Operational voltage AC min./max.
12 V - 250 V
Mounting orientation
Any
Mounting types
via through holes
Function
change-over contact (mechanical)
Protection class
IP65
Weight
0.16 kg
Materials:
Housing
Aluminum
Seals
Acrylonitrile Butadiene Rubber
Bellow
Brass
Electr. connection
Brass, nickel-plated
Technical Remarks
■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.
■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!
■ The microswitch has silver-plated contacts.
Type
Operating pressure range
min./max.
Compressed air
connection
Repeatability
(% of full scale
value)
Fig.
Note
Part No.
2)
R412010711
1); 3)
R412010712
1); 2)
R412010713
2)
R412010714
1); 3)
R412010715
1); 2)
R412010718
[bar]
PM1-M3-G014
-0.9 / 0
internal thread, G 1/4
±1%
Fig. 1
PM1-M3-G014
0.2 / 16
internal thread, G 1/4
±1%
Fig. 1
PM1-M3-F001
-0.9 / 0
Flange with O-ring, Ø
5x1,5
±1%
Fig. 2
PM1-M3-F001
0.2 / 16
Flange with O-ring, Ø
5x1,5
±1%
Fig. 2
1) Min. switching pressure range 0.2 bar falling/0.5 bar rising
2) Scope of delivery: with electrical connector
3) Scope of delivery: without electrical connector
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
4
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable
Fig. 1
73
9
15
Ø9
5,3
~ 81
M16x1,5
5
20
G1/4
30
30
43,5
2
~ 80
17184
1) Electrical connector
2) Adjustment screw, self-holding
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
5
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable
Fig. 2
68
4)
Ø9
10
5,3
~ 76
M16x1,5
5
20
5
30
30
43,5
3)
2
~ 80
17185
1) Electrical connector
2) Adjustment screw, self-holding
3) cylinder screw M5x30 (included in scope of delivery)
4) O-ring Ø5x1,5 (included)
PIN assignment for electrical connector
4)
1)
2)
3)
17186
1) +UB
2) break contact
3) make contact
4) GND
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
6
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable
differential switching pressure characteristic curve (-0,9 – 0 bar)
p1(+) bar
+0,2
+0,1
0
-0,1
-0,2
-0,3
-0,4
-0,5
-0,6
-0,7
-0,8
-0,9
-1,0
-1,0
-0,8 -0,7 -0,6 -0,5 -0,4 -0,3 -0,2
A)
B)
0
p1(-) bar
17187
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
7
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable
differential switching pressure characteristic curve (0,2 ‒ 16 bar)
p1(+) bar
16
15
14
13
12
11
10
9
p1 8
7
6
5
4
3
2
1
0
0
2
4
6
8
A)
10
12
14
B)
16
p1(-) bar
17188
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis
Example:
p1 (+) = 8 bar > p1(-) = 7.6 bar
Δ p1 = 0.4 bar
max. permissible continuous current I max. [A] with ohmic load
U [V]
30
48
60
125
250
I [A] 2)
3
1,2
0,8
0,4
–
I [A] 1)
5
5
5
5
5
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
max. permissible continuous current I max. [A] with inductive load
U [V]
30
48
60
125
250
I [A] 2) 4)
2
0.55
0.4
0.15
–
I [A] 1) 3)
3
3
3
3
3
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
8
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable
18043
Measurement
Relative pressure
Switching element
microswitch (input/output)
Switching frequency
1,5 Hz
Protection against overpressure
80 bar
Ambient temperature min./max.
-20°C / +80°C
Medium temperature min./max.
-10°C / +80°C
Medium
Compressed air
hydraulic oil
Shock resistance max.
(XYZ direction)
15 g
Vibration resistance
(XYZ direction)
10 g (60 - 500 Hz)
Switching point
adjustable
Hysteresis
max. switching pressure difference
DC operating voltage min./max.
12 V - 30 V
Operational voltage AC min./max.
12 V - 30 V
Mounting orientation
Any
Mounting types
via through holes
Function
change-over contact (mechanical)
Protection class
IP67
Weight
0.15 kg
Materials:
Housing
Aluminum
Seals
Acrylonitrile Butadiene Rubber
Bellow
Brass
Electr. connection
Brass, nickel-plated
Technical Remarks
■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.
■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!
■ The microswitch has silver-plated contacts.
Type
Operating pressure range
min./max.
Compressed air
connection
Repeatability
(% of full scale
value)
Fig.
Note
Part No.
[bar]
PM1-M3-G014
-0.9 / 0
internal thread, G 1/4
±1%
Fig. 1
-
R412010716
PM1-M3-G014
0.2 / 16
internal thread, G 1/4
±1%
Fig. 1
1)
R412010717
PM1-M3-F001
-0.9 / 0
Flange with O-ring, Ø
5x1,5
±1%
Fig. 2
-
R412010719
PM1-M3-F001
0.2 / 16
Flange with O-ring, Ø
5x1,5
±1%
Fig. 2
1)
R412010720
1) Min. switching pressure range 0.2 bar falling/0.5 bar rising
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
9
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable
Fig. 1
9
Ø9
15
5,3
73
M12x1
2
5
20
G1/4
30
30
43,5
2
~ 59
17189
1) Adjustment screw, self-holding
2) Detent position
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
10
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable
Fig. 2
68
M12x1
4)
Ø9
10
5,3
3)
5
20
5
2)
30
30
43,5
2
~ 59
17190
1) Adjustment screw, self-holding
2) cylinder screw M5x30 (included in scope of delivery)
3) O-ring Ø5x1,5 (included)
4) Detent position
Pin assignments
2)
3)
1)
4)
00127752
1) +UB
2) break contact
3) No function
4) make contact
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
11
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable
differential switching pressure characteristic curve (-0,9 – 0 bar)
p1(+) bar
+0,2
+0,1
0
-0,1
-0,2
-0,3
-0,4
-0,5
-0,6
-0,7
-0,8
-0,9
-1,0
-1,0
-0,8 -0,7 -0,6 -0,5 -0,4 -0,3 -0,2
A)
B)
0
p1(-) bar
17187
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
12
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable
differential switching pressure characteristic curve (0,2 ‒ 16 bar)
p1(+) bar
16
15
14
13
12
11
10
9
p1 8
7
6
5
4
3
2
1
0
0
2
4
6
A)
8
10
12
14
B)
16
p1(-) bar
17188
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis
Example:
p1 (+) = 8 bar > p1(-) = 7.6 bar
Δ p1 = 0.4 bar
max. permissible continuous current I max. [A] with ohmic load
U [V]
30
I [A] 2)
3
I [A] 1)
4
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
max. permissible continuous current I max. [A] with inductive load
U [V]
30
I [A] 2) 4)
2
I [A] 1) 3)
3
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
13
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable ► ATEX certified
21212
ATEX
II 3G Ex nAC IIC T6 X
II 3D Ex tD A22 IP65 T 80° C X
Measurement
Relative pressure
Switching element
microswitch (input/output)
Switching frequency
1,5 Hz
Protection against overpressure
80 bar
Ambient temperature min./max.
+0°C / +80°C
Medium temperature min./max.
+0°C / +80°C
Medium
Compressed air
hydraulic oil
Shock resistance max.
(XYZ direction)
15 g
Vibration resistance
(XYZ direction)
10 g (60 - 500 Hz)
Switching point
adjustable
Hysteresis
max. switching pressure difference
DC operating voltage min./max.
12 V - 125 V
Operational voltage AC min./max.
12 V - 250 V
Mounting orientation
Any
Mounting types
via through holes
Function
change-over contact (mechanical)
Protection class
IP65
Weight
0.16 kg
Materials:
Housing
Aluminum
Seals
Acrylonitrile Butadiene Rubber
Bellow
Brass
Electr. connection
Brass, nickel-plated
Technical Remarks
■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.
■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!
■ The microswitch has silver-plated contacts.
Type
Operating pressure range
min./max.
PM1-M3-G014
-0.9 / 1
internal thread, G 1/4
PM1-M3-G014
0.2 / 16
internal thread, G 1/4
0.2 / 16
Flange with O-ring, Ø
5x1,5
PM1-M3-F001
[bar]
Compressed air
connection
Repeatability
(% of full scale
value)
±1%
Fig.
Note
Part No.
Fig. 1
-
R412010727
Fig. 1
1)
R412010728
Fig. 2
1)
R412010729
1) Min. switching pressure range 0.2 bar falling/0.5 bar rising
Delivery contents: including electrical connector
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
14
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable ► ATEX certified
Fig. 1
73
9
15
Ø9
5,3
~ 81
M16x1,5
5
20
G1/4
30
30
43,5
2
~ 80
17208
1) Electrical connector
2) Adjustment screw, self-holding
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
15
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable ► ATEX certified
Fig. 2
68
4)
Ø9
10
5,3
~ 76
M16x1,5
5
20
5
30
30
43,5
3)
2
~ 80
17209
1) Electrical connector
2) Adjustment screw, self-holding
3) cylinder screw M5x30 (included in scope of delivery)
4) O-ring Ø5x1,5 (included)
PIN assignment for electrical connector
4)
1)
2)
3)
17186
1) +UB
2) break contact
3) make contact
4) GND
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
16
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable ► ATEX certified
differential switching pressure characteristic curve (-0,9 – 1 bar)
P1
(+) bar
+1,2
+1,1
+1,0
1)
+0,9
2)
+0,8
+0,7
+0,6
+0,5
+0,4
+0,3
+0,3
+0,1
P1
(-) bar
P1
(+) bar
-0,1
-0,2
-0,3
-0,4
-0,5
-0,6
-0,7
-0,8
-0,9
-1,0
-1,0
-0,8
-0,6
-0,4
-0,2
P1
(-) bar
+0,2
+0,4
+0,6
+0,8
+1,0
17210
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
17
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Spring-loaded
bellow, adjustable ► ATEX certified
differential switching pressure characteristic curve (0,2 ‒ 16 bar)
p1(+) bar
16
15
14
13
12
11
10
9
p1 8
7
6
5
4
3
2
1
0
0
2
4
6
8
A)
10
12
14
B)
16
p1(-) bar
17188
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis
Example:
p1 (+) = 8 bar > p1(-) = 7.6 bar
Δ p1 = 0.4 bar
max. permissible continuous current I max. [A] with ohmic load
U [V]
30
48
60
125
250
I [A] 2)
3
1,2
0,8
0,4
–
I [A] 1)
5
5
5
5
5
1) AC
2) DC
max. permissible continuous current I max. [A] with inductive load
U [V]
30
48
60
125
250
I [A] 2) 4)
2
0.55
0.4
0.15
–
I [A] 1) 3)
3
3
3
3
3
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
18
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable ► ATEX certified
17211
ATEX
II 3G Ex nAC IIC T6 X
II 3D Ex tD A22 IP67 T 80° C X
Measurement
Relative pressure
Switching element
microswitch (input/output)
Switching frequency
1,5 Hz
Protection against overpressure
80 bar
Ambient temperature min./max.
+0°C / +80°C
Medium temperature min./max.
+0°C / +80°C
Medium
Compressed air
hydraulic oil
Shock resistance max.
(XYZ direction)
15 g
Vibration resistance
(XYZ direction)
10 g (60 - 500 Hz)
Switching point
adjustable
Hysteresis
max. switching pressure difference
DC operating voltage min./max.
12 V - 30 V
Operational voltage AC min./max.
12 V - 30 V
Mounting orientation
Any
Mounting types
via through holes
Function
change-over contact (mechanical)
Protection class
IP67
Weight
0.16 kg
Materials:
Housing
Aluminum
Seals
Acrylonitrile Butadiene Rubber
Bellow
Brass
Electr. connection
Brass, nickel-plated
Technical Remarks
■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.
■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!
■ The microswitch has silver-plated contacts.
Type
Operating pressure range
min./max.
Compressed air
connection
Repeatability
(% of full scale
value)
Fig.
Note
Part No.
internal thread, G 1/4
±1%
Fig. 1
-
R412010730
[bar]
PM1-M3-G014
-0.9 / 1
PM1-M3-G014
PM1-M3-F001
internal thread, G 1/4
0.2 / 16
Flange with O-ring, Ø
5x1,5
Fig. 1
±1%
Fig. 2
R412010731
1)
R412010732
1) Min. switching pressure range 0.2 bar falling/0.5 bar rising
Delivery contents: including electrical connector and cable (5 m)
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
19
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable ► ATEX certified
Pin assignment M12x1
2)
3)
1)
4)
00127752
1) +UB
2) break contact
3) No function
4) make contact
differential switching pressure characteristic curve (-0,9 – 1 bar)
P1
(+) bar
+1,2
+1,1
+1,0
1)
+0,9
2)
+0,8
+0,7
+0,6
+0,5
+0,4
+0,3
+0,3
+0,1
P1
(-) bar
P1
(+) bar
-0,1
-0,2
-0,3
-0,4
-0,5
-0,6
-0,7
-0,8
-0,9
-1,0
-1,0
-0,8
-0,6
-0,4
-0,2
P1
(-) bar
+0,2
+0,4
+0,6
+0,8
+1,0
17210
1) Rising
2) Falling
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
20
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: -0.9 - 16 bar ► mechanical ► electr. connection: Plug, M12x1 ► Spring-loaded bellow,
adjustable ► ATEX certified
differential switching pressure characteristic curve (0,2 ‒ 16 bar)
p1(+) bar
16
15
14
13
12
11
10
9
p1 8
7
6
5
4
3
2
1
0
0
2
4
6
A)
8
10
12
14
B)
16
p1(-) bar
17188
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
Δ p1 = max. operating pressure difference or hysteresis
Example:
p1 (+) = 8 bar > p1(-) = 7.6 bar
Δ p1 = 0.4 bar
max. permissible continuous current I max. [A] with ohmic load
U [V]
30
I [A] 2)
3
I [A] 1)
4
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
max. permissible continuous current I max. [A] with inductive load
U [V]
30
I [A] 2) 4)
2
I [A] 1) 3)
3
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
21
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air
connection: CNOMO ► Spring-loaded bellow, non-adjustable
18832
Measurement
Relative pressure
Switching element
microswitch (input/output)
Switching frequency
1,5 Hz
Protection against overpressure
80 bar
Ambient temperature min./max.
-20°C / +80°C
Medium temperature min./max.
-10°C / +80°C
Medium
Compressed air
hydraulic oil
Shock resistance max.
(XYZ direction)
15 g
Vibration resistance
(XYZ direction)
10 g (60 - 500 Hz)
Repeatability (% of full scale value)
±1%
Switching point
adjustable
Hysteresis
max. switching pressure difference
DC operating voltage min./max.
12 V - 30 V
Operational voltage AC min./max.
12 V - 250 V
DC switching current, max.[A]
3
Mounting orientation
Any
Mounting types
via through holes
Function
change-over contact (mechanical)
Protection class
IP65
Weight
0.16 kg
Materials:
Housing
Aluminum
Bellow
Brass
Electr. connection
Brass, nickel-plated
Technical Remarks
■ Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.
■ Set to 1.5 bar operating pressure. Adjustment screw secured and covered by an adhesive label.
■ Notice: Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!
■ The microswitch has silver-plated contacts.
Type
Operating pressure range
min./max.
Part No.
[bar]
PM1-M3-F001
0.2 / 16
Min. switching pressure range 0.2 bar falling/0.5 bar rising
Scope of delivery: without electrical connector
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
R412010721
22
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air
connection: CNOMO ► Spring-loaded bellow, non-adjustable
Ø8
1,5
4,2
3,8
10
68
Dimensions
5
4,5
30
21
43,5
30
17192
PIN assignment for electrical connector
4)
1)
2)
3)
17186
1) +UB
electric for 12-24 V DC, break contact
3) make contact
4) GND
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
23
Sensor technologies ► Pressure sensors
Pressure Switches, Series PM1
► Operating pressure: 0.2 - 16 bar ► mechanical ► electr. connection: Plug, ISO 4400, form A ► Compressed air
connection: CNOMO ► Spring-loaded bellow, non-adjustable
differential switching pressure characteristic curve (0,2 ‒ 16 bar)
p1(+) bar
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
2
4
6
8
A)
10
12
14
B)
16
p1(-) bar
17193
A) p1 (-), min.
B) p1 (-), max.
p1 (+) = upper switching pressure with increasing pressure
p1 (-) = lower switching pressure with decreasing pressure
max. permissible continuous current I max. [A] with ohmic load
U [V]
30
48
60
125
250
I [A] 2)
3
1,2
0,8
0,4
–
I [A] 1)
5
5
5
5
5
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
max. permissible continuous current I max. [A] with inductive load
U [V]
30
48
60
125
250
I [A] 2) 4)
2
0.55
0.4
0.15
–
I [A] 1) 3)
3
3
3
3
3
reference cycle: 30/min., reference temperature: +30°C
1) AC
2) DC
3) cos ≈ 0,7°
4) L/R ≈ 10 ms
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
24
Sensor technologies ► Pressure sensors
Series PM1
Accessories
Connecting cable, Series CN2
► Socket, M12, 5-pin, A-coded ► without wire end ferrule, tin-plated, 4-pin
Ambient temperature min./max.
-40°C / +85°C
Protection class
IP65
Materials:
Cable sheath
Polyurethane
00107009_c
Technical Remarks
■ The specified protection class is valid only in assembled and tested state.
-20% / +20%
max.
[V
DC]
300
[V
AC]
250
Max. current
Number
of wires
[A]
4
4
Wire
cross-section
[mm²]
0.34
Cable exit
angled 90°
Cable length
L
Weight
[m]
[kg]
Part No.
3
0.13
1834484259
5
0.202
1834484260
10
0.387
1834484261
Dimensions
00107205_b
(1) BN=brown (2) WH=white (3) BU=blue (4) BK=black
(5) not assigned
L = length
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
25
Sensor technologies ► Pressure sensors
Series PM1
Accessories
Electrical connectors, Series CN1
► ISO 4400 ► Electrical connector, form A ► 18 mm
Ambient temperature min./max.
-40°C / +90°C
Protection class
IP65
mounting screw tightening torque
0.4 Nm
00110264_a
Technical Remarks
■ The specified protection class is valid only in assembled and tested state.
Cable fitting
1
2
3
-20% /
+20%
DC
[V]
Max. current
Contact assignment
Cable exit
suitable cable-Ø min./max
M16x1,5
300
10
3+E
angled 90°
6/8
1834484059
M20x1,5
24
8
3+E
angled 90°
4.5 / 11
8941012462
[A]
Part No.
[mm]
1
2
3
gn/ge
1
2
3
4
1
2
3
Part No.
number of plug options 1
Status display
LED status
display
Housing color
1834484059
4 positions each 90°
-
-
Black
8941012462
1 position
2 LED
GreenRed
Transparent
1) electrical connector with status display (2 LED) for pressure sensor
2) Profile seal
3) Flat gasket
4) Housing: Polyamide
Seal: caoutchouc/butadiene caoutchouc
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
Weight
[kg]
Note
0.03
2)
0.03
1); 2); 4)
26
Sensor technologies ► Pressure sensors
Series PM1
Accessories
Dimensions
00110274
1) Max.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2014-10-14, ©AVENTICS S.a.r.l., subject to change
Aventics GmbH
Ulmer Straße 4
30880 Laatzen
Phone +49 511 2136-0
Fax +49 511 2136-269
www.aventics.com
info@aventics.com
Find more contact information at
www.aventics.com/contact
Only use the AVENTICS products
shown in industrial applications.
Read the product documentation
completely and carefully before using
the product.
Observe the applicable regulations
and laws of the respective country.
When integrating the product into
applications, note the system
manufacturer’s specifications for safe
use of the product.
The data specified only serve to
describe the product.
No statements concerning a certain
condition or suitability for a certain
application can be derived from our
information.
The information given does not
release the user from the obligation
of own judgment and verification.
It must be remembered that the
products are subject to a natural
process of wear and aging.
14-10-2014
An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration.
Subject to change. © AVENTICS S.à.r.l.. This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of AVENTICS S.a.r.l.. It may not be reproduced or given to third parties without its
consent. PDF online