4000 Series active loudspeakers Presson © Compact and powerful Genelec 4010A, 4020B, 4030B and 4040A are compact but powerful two-way active loudspeakers designed for indoor commercial and professional installations. All models contain an integrated amplification unit comprising an active electronic crossover, overload protection circuitry and two power amplifiers, one for each driver. Designing the power amplifiers, active crossover, drivers and loudspeaker enclosure as one integrated unit presents a number of benefits: •Excellent sound quality due to exact matching of the crossover, amplifiers and drivers. •High sound pressure capability despite a small enclosure. •Reliable overload protection circuitry for the amplifiers and drivers. •Precise Room Response Controls for optimising the loudspeaker’s response to suit different acoustical environments. •No need for external power amplifiers. •Balanced 10 kOhm line level audio input for easy and interference-resistant cabling. 4000 Series active loudspeakers for AV install 3 Active in professional installations Aluminium enclosure All Genelec 4000 Series designs incorporate the innovative die-cast aluminium Minimum Diffraction Enclosure™ (MDE™) which features a relatively large internal volume, softly rounded edges and outstanding mechanical strength. As a result, the imaging accuracy and low frequency extension with such a compact enclosure are truly astounding. The enclosure design also incorporates the advanced Directivity Control Waveguide™ (DCW™) for the tweeter, providing an amazingly smooth on and off axis response and a long, curved reflex port ending in a wide flare for excellent bass articulation. Both drivers are protected by sturdy metal grilles. Integrated support The integrated support points for Omnimount and/or König & Meyer mounting hardware on the enclosure back panel and a threaded hole at the base of the enclosure provide versatile mounting options for all installations. A wall mount bracket is included in the loudspeaker package, with a wide range of accessories available from your local Genelec dealer or the Genelec WebShop. Controls and Power Management Calibrated Bass Tilt, Treble Tilt and Bass RollOff controls allow matching the 4000 Series loudspeakers to any acoustic environment. Power management is by 12 V trigger voltage or signal sensing Autostart function. Power consumption in Standby mode is less than 0.5 Watts. INTELLIGENT SIGNAL SENSING POWER MANAGEMENT Significant reduction of power consumption in Standby mode Presson © 4010A 115 mm [4 1/2"] 121 mm [4 3/4"] Center of gravity 63 mm [2 1/2"] 292-4010S ON ISS DISABLE SENSITIVITY -10 dB TREBLE TILT +2 dB BASS TILT -2 dB BASS TILT -4 dB MAINS INPUT 50 / 60 Hz 30 W 100 - 240 V~ + - GND 710127 This device complies with FCC Part 15 and Canadian ICES-003 radio frequency Class B emission requirements. Refer to operating manual for full information. Genelec Oy 4010 292-4010T 4010A ACTIVE SPEAKER SYSTEM MADE IN FINLAND www.genelec.com Acoustic axis 107 mm [4 3/16”] 292-6010W AVERTISSEMENT Center of gravity 84 mm [3 5/16”] 181 mm [7 1/8”] WARNING ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT SUBJECT TO WATER OR MOISTURE. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS EXPOSER À L'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À L'INTÉRIEUR REMPLAÇABLE PAR L'UTILISATEUR. ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ. (dBr) vs freq (Hz) 10 Jan 13 Genelec Oy 4010 90 d B 85 r 90 d B 85 r A 80 A 80 75 75 (dBr) vs freq (Hz) 10 Jan 13 0° 15° 85 30° 70 BASS TILT 45° 80 60° 65 75 70 TREBLE TILT 70 65 40 70 100 200 500 1k 2k 5k 10k 40 20k Hz The effect of the Bass Tilt and Treble Tilt controls on the free field response. 70 100 200 500 1k 4010A Frequency of > 150 deg dispersion (Hz) Horizontal Vertical 130 110 5k 10k 20k Hz The curves above show the horizontal directivity characteristics of the loudspeaker. The lower curve shows the loudspeaker’s power response. Horizontal and vertical directivity plot Dispersion angle (degrees) 2k 2000 4020B Genelec Oy 4020 (dBr) vs freq (Hz) 7 Nov 12 Genelec Oy 4020 90 d B 85 r 90 d B 85 r A 80 A 80 TREBLE TILT 75 (dBr) vs freq (Hz) 7 Nov 12 0° 15° 30° 75 BASS TILT 85 70 45° 80 60° 65 75 BASS ROLL-OFF 70 40 70 100 200 500 1k 2k 5k 10k 40 20k Hz The effect of the Bass Tilt, Bass Roll-Off and Treble Tilt controls on the free field response. 70 100 200 500 1k 2k 5k 10k 20k Hz The curves above show the horizontal directivity characteristics of the loudspeaker. The lower curve shows the loudspeaker’s power response. Horizontal and vertical directivity plot 4020B Dispersion angle (degrees) Frequency of > 150 deg dispersion (Hz) Horizontal Vertical 120 100 4000 Series active loudspeakers for AV install 1500 7 4030B Genelec Oy 4030 (dBr) vs freq (Hz) 7 Nov 12 Genelec Oy 4030 95 d B 90 r (dBr) vs freq (Hz) 7 Nov 12 100 95 A 85 TREBLE TILT 80 BASS TILT 90 d B r A 90 0° 15° 30° 85 80 85 75 80 100 70 45° 60° BASS ROLL-OFF 75 95 65 90 60 55 30 50 100 200 500 1k 2k 5k 10k 50 30 20k Hz The effect of the Bass Tilt, Bass Roll-Off and Treble Tilt controls on the free field response. 50 100 200 500 4030B Frequency of > 150 deg dispersion (Hz) Horizontal Vertical 120 100 2k 5k 10k 20k Hz The curves above show the horizontal directivity characteristics of the loudspeaker. The lower curve shows the loudspeaker’s power response. Horizontal and vertical directivity plot Dispersion angle (degrees) 1k 1000 4040A 223 mm [8 13/16”] 237 mm [9 3/8”] NOTE! THIS MONITOR SHOULD NOT BE MOUNTED ON A MICROPHONE STAND AS THE BASE THREAD IS M10. 292-8040W AVERTISSEMENT RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS EXPOSER À L'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À L'INTÉRIEUR REMPLAÇABLE PAR L'UTILISATEUR. ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ. CET APPAREIL DOIT ÊTRE RACCORDÉ À LA TERRE. www.genelec.com _ + GND +12V 4040A ACTIVE SPEAKER SYSTEM MADE IN FINLAND Genelec Oy 4040 GND OFF REMOTE MAINS SWITCHING ON SERIAL NUMBER 292-4040T-6 MAINS INPUT 50 / 60 Hz 170 W 230 V~ BALANCED INPUT SIGNAL NOTE! CE MONITEUR NE DOIT PAS ÊTRE MONTÉ SUR UN PIED DE MICROPHONE CAR LE PAS DE VIS EST DE TYPE M10. Acoustic axis 225 mm [8 7/8”] WARNING ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT SUBJECT TO WATER OR MOISTURE. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. USE EARTHED MAINS CONNECTION ONLY. Center of gravity 162 mm [6 3/8”] 350 mm [13 3/4”] Center of gravity 114 mm [4 1/2”] (dBr) vs freq (Hz) 31 Jul 12 Genelec Oy 4040 95 d B 90 r 95 d B 90 r A 85 A 85 80 (dBr) vs freq (Hz) 31 Jul 12 0° 15° 30° 80 TREBLE TILT BASS TILT 90 75 45° 85 60° 70 80 65 BASS ROLL-OFF 75 60 30 50 100 200 500 1k 2k 5k 10k 20k Hz 30 The effect of the Bass Tilt, Bass Roll-Off and Treble Tilt controls on the free field response. 50 100 200 500 1k 2k 5k 10k 20k Hz The curves above show the horizontal directivity characteristics of the loudspeaker. The lower curve shows the loudspeaker’s power response. Horizontal and vertical directivity plot 4040A Dispersion angle (degrees) Frequency of > 150 deg dispersion (Hz) Horizontal Vertical 110 100 4000 Series active loudspeakers for AV install 800 9 Accessories Genelec offers a wide range of accessories for the 4000 series active loudspeakers. Below are only a few samples of the full Genelec Accessories range. Please visit Genelec WebShop to see the current selection and to place your order at www.genelec.com/webshop/loudspeaker-accessories.html. You can also purchase these accessories through your local Genelec dealer. Fixed wall mount for 4020B and 4030B. A keyhole type wall mount bracket is included with each loudspeaker. 8000-410B Black 8000-410W White Adjustable wall mount with T-plate for 4010, 4020 and 4030. Available in black or white. 8000-422B Black (K&M 24160-000-56) 8000-422W White (K&M 24160-000-66) With this small VESA adapter one can mount 4020B or 4030B loudspeakers into any kind of VESA 75/100 based accessories. Adjustable wall mount for 4030 and 4040. Available in black or white. Security wire available - part no. 8000-418B. 8000-437B VESA adapter 75/100 mm 8000-402B Black (K&M 24475-000-55) 8000-402W White (K&M 24475-000-57) Short ceiling mount for 4020B and 4030B. Available in black or white. Additional security wire, 420 mm. Also suitable for wall mount - part no. 8000-402. 8000-435B Black (K&M 24485-000-55) 8000-435W White (K&M 24485-000-57) 8000-418B (K&M 24521-901-55) Technical specifications 4010A 4020B 4030B 4040A Lower cut-off frequency, -6 dB < 67 Hz < 59 Hz < 50 Hz < 50 Hz Upper cut-off frequency, -6 dB > 25 kHz > 25 kHz > 25 kHz > 25 kHz Free field frequency response 74 Hz - 18 kHz (± 2.5 dB) 66 Hz - 20 kHz (± 2.5 dB) 58 Hz - 20 kHz (± 2.5 dB) 55 Hz - 20 kHz (± 3.0 dB) Maximum short term sine wave acoustic output on axis in half space, averaged from 100 Hz to 3 kHz @ 1 m > 96 dB SPL @ 1 m > 96 dB SPL @ 1 m > 100 dB SPL @ 1 m > 109 dB SPL Maximum long term RMS acoustic output in same conditions with IEC weighted noise (limited by driver unit protection circuit) @ 1 m > 91 dB SPL @ 1 m > 95 dB SPL @ 1 m > 97 dB SPL @ 1 m > 101 dB SPL Maximum peak acoustic output per pair with music material @ 1 m > 102 dB @ 1 m > 105 dB @ 1 m > 108 dB @ 1 m > 114 dB Self generated noise level in half space at 1 m on axis (A-weighted) < 5 dB < 10 dB < 10 dB < 10 dB Harmonic distortion at given SPL at 1 m on axis 85 dB SPL 70...400 Hz < 3 % > 400 Hz < 0.5 % 85 dB SPL 50…100 Hz < 3 % > 100 Hz < 0.5 % 85 dB SPL 50…100 Hz < 2 % > 100 Hz < 0.5 % 90 dB SPL 50…100 Hz < 3 % > 100 Hz < 0.5 % 76 mm (3 in) cone 19 mm (3/4 in) metal dome 105 mm (4 in) cone 19 mm (3/4 in) metal dome 130 mm (5 in) cone 19 mm (3/4 in) metal dome 165 mm (61/2 in) cone 19 mm (3/4 in) metal dome Weight 1.5 kg (3.3 lb) 3.6 kg (7.9 lb) 5.5 kg (12.1 lb) 9.9 kg (22 lb) Dimensions Height Width Depth 181 mm (71/8 in) 121 mm (43/4 in) 114 mm (41/2 in) 226 mm (87/8 in) 151 mm (6 in) 142 mm (55/8 in) 285 mm (111/4 in) 189 mm (77/16 in) 178 mm ( 71/16 in) 350 mm (133/16 in) 237 mm (93/8 in) 223 mm ( 813/16 in) Amplifier section 4010A 4020B 4030B 4040A Bass amplifier short term output power Treble amplifier short term output power 25 W 25 W 20 W 20 W 40 W 40 W 120 W 120 W Amplifier system THD at nominal output < 0.08 % < 0.08 % < 0.08 % < 0.05 % Mains voltage Voltage operating range 100 - 240 V Drivers Bass Treble Long term output power is limited by driver unit protection circuitry Power consumption (average) Standby Idle Full output Crossover section 100, 120, 220 or 230 V AC according to region ±10 % <0.5 W 5W 30 W <0.5 W 5W 50 W <0.5 W 10 W 80 W <0.5 W 15 W 170 W 4010A 4020B 4030B 4040A Signal input connector Balanced 10 kOhm Phoenix connector Input level for 100 dB SPL output at 1 m -6 dBu (Sensitivity -10 dB OFF) -6 dBu at volume control max Sensitivity control range -10 dB (Sensitivity -10 dB ON) -40 dB relative to max output -12 dB Output signal level is 0 dB relative to input signal level but adjustable by sensitivity control Crossover frequency, Bass/Treble 3.0 kHz 3.0 kHz 3.0 kHz 2.5 kHz Treble Tilt control operating range 0 to -2 dB @ 5 kHz 0 to -2 dB @ 15 kHz 0 to -2 dB @ 15 kHz +2 to -4 dB @ 15 kHz + Mute Bass Tilt control operating range in 2 dB steps From 0 to -6 dB @ 100 Hz From 0 to -6 dB @ 100 Hz From 0 to -6 dB @ 100 Hz From 0 to -6 dB @ 100 Hz + Mute Bass Roll-Off control N/A -6 dB step @ 85 Hz -6 dB step @ 85 Hz From 0 to -6 dB @ 55 Hz The ‘CAL’ position is with all tone controls set to ‘off’ and the input sensitivity control to maximum (fully clockwise). 4000 Series active loudspeakers for AV install 11 www.genelec.com Genelec Oy Olvitie 5 · 74100 Iisalmi · Finland T +358 17 83 881 · F +358 17 81 2267 Email: genelec@genelec.com Genelec Document BBAGE069d. Copyright Genelec Oy 2015. All data subject to change without prior notice.
© Copyright 2024