Better Boilers www.ibcboiler.com FEATURING OUR IBC SUPREME “SUPER COIL” 316TI STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat Exchanger ever made. With more than 14 years of production excellence, utilizing the latest advances in burner, gas air mixing and control technology the “Super Coil” delivers the lowest flue gas exhaust temperature / return water temperature differential. VFC 15-150 15,000 to 150,000 BTU/H VFC 45-225 45,000 to 225,000 BTU/H New Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust VFC 15-150 became the first and industry leading 10:1 turndown ratio residential-scale modulating boiler in North America. Span the range from small cottage to sprawling mansion. Sustained high efficiency across firing range even at high temperatures Built-in 4-load priority management and switching Unmatched durability from our exclusive 316Ti stainless steel exchanger 80psi “Super Coil” heat Control 5 independent pumps directly from the boiler without additional relays Contractor friendly with easy to use controls, wiring and serviceability Go anywhere venting options up to 480 feet! Specifications VFC 15-150 VFC 45-225 CSA Input (Natural Gas or Propane *) - MBH 15 - 150 45 - 225 CSA Input (Natural Gas or Propane *) - KW 4.4 - 44 13 - 66 CSA Output - MBH 14 - 139 12 - 60 CSA Output - KW 4.1 - 41 12.7 - 70.0 A.F.U.E 95.00% 95.00% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire - Watts 57 57 Weight (empty) - lbs/Kg 150 / 68 153 / 70 Pressure vessel water content – USG/Liters 2.4 / 9 2.4 / 9 Max boiler flow rate - USgpm 4 8 Min boiler flow rate - USgpm 16 25 Max operating pressure - psig 80 80 Min water pressure - psig 8 8 Normal flue temp @ 160°F boiler return water temp - High Fire 100°F to 105°F 100°F to 105°F Normal flue temp @ 160°F boiler return water temp - High Fire 160°F to 165°F 160°F to 165°F Approved installation altitude - ASL 0 - 12,000 ft 0 - 12,000 ft Ambient temperature - Low (°F/°C) 32°F / 0°C 32°F / 0°C Ambient temperature - High (°F/°C) 122°F / 50°C 122°F / 50°C Max relative humidity (non-condensing) 90.00% 90.00% Min water Temperature (°F/°C) 34°F / 1.1°C 34°F / 1.1°C Max water Temperature (electronic-limit) (°F/°C) 190°F / 87.7°C 190°F / 87.7°C Max water Temperature (mechanical hi-limit) (°F/°C) 200°F / 93.3°C 200°F / 93.3°C Max Δ T - supply / return (electronic fence) 36°F 35°F Maximum equivalent vent length each side 2” 50' N/A Maximum equivalent vent length each side 3” 120' 240' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Ships with 30psi relief valve IBC boilers are not de-rated because of longer vent runs Better efficiency 95% AFUE Exhaust pipe size Maximum equivalent length Sched.40; Rigid PPs 2” (15-150 only) 50’ (each side) 2 1/2” (15-150 only) 70’ Venting up to 480 Feet! 3” (15-150) 120’ 240’ Exhaust + 240’ Intake 3” (45-225) 240’ 90° vent elbow Allow 8’ equivalent 45° elbow Allow 3’ equivalent PP’s 87-90° elbows Allow 8’ equivalent Flexible PPs 2” Flexible 60’ (see note 1) 3” Flexible 60’ (see note 2) www.ibcboiler.com VFC Series PREMIER CONDENSING BOILERS Automated laser welding now underway SL SERIES - BETTER INSTALLATION FLEXIBILITY Made of high grade 439 stainless steel the SL Heat Exchangers deliver 95% AFUE efficiency. The SL Heat Exchangers are easy to inspect and features a condensate draining system that cleans as it heats. With more models and now featuring our new IBC Touch Screen Boiler Control you get all the features of our 5 button control with the following added features: Express Set Up, Easier Diagnostics & Intuitive Alert System with plain English warnings & error messages. There is an SL model for every application. SL 20-115G2 28,000 to 160,000 BTU/H Supply RESIDENTIAL CONDENSING BOILERS With Supply and Return connections on both sides of the boiler your installation can’t get any easier. Use the left side, the right side or both. The choice is yours. New Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust Built-in 4-load priority management and switching Connect your IBC Indirect Water Tank directly to the boiler without a primary loop Industry leading turndown ratio of 5.75 : 1 means you have the power to heat your home in the coldest weather yet reduce short cycling when the weather is mild Built-in outdoor reset control of water temperature Better efficiency 95% AFUE Specifications SL 20-115G2 CSA Input (Natural Gas or Propane *) - MBH 20 - 115 28 - 160 CSA Input (Natural Gas or Propane *) - KW 6 - 34 8.2 - 47 CSA Output - MBH 19 - 109 26.2 - 147 CSA Output - KW 5.5 - 32 7.7 - 43 A.F.U.E 95.0% 95.0% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire - Watts ( without pumps) 54 73 Weight (empty) - lbs/Kg 85/39 102 / 46.3 Pressure vessel water content – USG/Liters 2.9 / 11 3.2 / 12.2 Max boiler flow rate - USgpm 14 19 Min boiler flow rate - USgpm 2 4 Max operating pressure - psig 30 30 Min water pressure - psig 8 8 Approved installation altitude - ASL 0 - 12,000 ft 0 - 12,000 ft Ambient temperature - Low (°F/°C) 32°F / 0°C 32°F / 0°C Ambient temperature - High (°F/°C) 122°F / 50°C 122°F / 50°C Max relative humidity (non-condensing) 90.00% 90.00% Min water Temperature (°F/°C) 34°F / 1.1°C 34°F / 1.1°C Max water Temperature (electronic-limit) (°F/°C) 190°F / 87.8°C 190°F / 87.8°C Max water Temperature (mechanical hi-limit) (°F/°C) 200°F / 93.3°C 200°F / 93.3°C Max Δ T - supply / return (electronic fence) 40°F 40°F SL 28-160 Maximum equivalent vent length, each side 2” 100' 35' Maximum equivalent vent length, each side 3” 240' 170' Return (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Ships with 30psi relief valve Very low water side and combustion side pressure drops Venting up to 480 feet on the SL 20-115G2 Left and right clearance as low as 1” Limited lifetime residential warranty Exhaust pipe size Maximum equivalent length SL 20-115G2 SL 28-160 2” 100’ 35’ 3” 240’ 170’ 90° long sweep elbow Allow 5’ equivalent Allow 5’ equivalent 90° vent elbow Allow 8’ equivalent Allow 8’ equivalent 45° elbow Allow 3’ equivalent Allow 3’ equivalent PPs 87-90° elbows Allow 8’ equivalent Allow 8’ equivalent Sched.40; Rigid PPs Flexible PPs 2” Flexible 45’ (max) lineal x 1.4 = equivalent 3” Flexible 45’ (max) actual lineal x 1.2 = equivalent Supply 98’ (max) actual lineal x 1.2 = equivalent www.ibcboiler.com Return SL Series 20,000 to 115,000 BTU/H SL 28-160 SL 35-199 SL 45-260 35,000 to 199,000 BTU/H 45,000 to 260,000 BTU/H New to the SL Series the SL 35-199 expands the capacity of the former SL 30-175 and with the new IBC touch screen controller offers the most flexible control option on the market. New Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust Built-in 4-load priority management and switching LWCO options available Bottom piping connections for easy network piping Better installation flexibility Connect your IBC Indirect Water Tank directly to the boiler without a primary loop means you have the power to heat your home in the coldest weather yet reduce short cycling when the weather is mild outdoor temperature reset control SL 35 -199 SL 45 - 260 CSA Input (Natural Gas or Propane *) - MBH 35 - 199 45 - 260 CSA Input (Natural Gas or Propane *) - KW 10.3 - 58.3 13.2 - 76.2 CSA Output - MBH 32.7 - 181.3 43.2 - 239 CSA Output - KW 7.7 - 43 12.7 - 70.0 A.F.U.E 95.00% 95.00% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire - Watts 92 127 Weight (empty) - lbs/Kg 151 / 69 162 / 74 Pressure vessel water content – USG/Liters 5 / 19 5 / 19 Max boiler flow rate - USgpm 25 25 Min boiler flow rate - USgpm 6 6 Max operating pressure - psig 30 30 Min water pressure - psig 8 8 Approved installation altitude - ASL 0 - 12,000 ft 0 - 12,000 ft Ambient temperature - Low (°F/°C) 32°F / 0°C 32°F / 0°C Ambient temperature - High (°F/°C) 122°F / 50°C 122°F / 50°C Max relative humidity (non-condensing) 90.00% 90.00% Min water Temperature (°F/°C) 34°F / 1.1°C 34°F / 1.1°C Max water Temperature (electronic-limit) (°F/°C) 190°F / 88°C 190°F / 88°C Max water Temperature (mechanical hi-limit) (°F/°C) 200°F / 93.°C 200°F / 93.°C Max Δ T - supply / return (electronic fence) 40°F 40°F Maximum equivalent vent length each side 3” 200' 200' Maximum equivalent vent length each side 4” 200' 200' (Natural Gas or Propane) Industry leading turndown ratio of 5.75 : 1 Built-in Specifications of water Air intake options: either direct vent or indoor supply Ships with 30psi relief valve Exhaust pipe size Maximum equivalent length Sched.40; Rigid PPs Better efficiency 95% AFUE 3” 200’ Very low water side and combustion side 4” 200’ 90° long sweep elbow Allow 5’ equivalent 90° vent elbow Allow 8’ equivalent 45° elbow Allow 3’ equivalent PP’s 87-90° elbows Allow 8’ equivalent pressure drops Venting up to 400 feet Flexible PPs 3” Flexible (SL 35-199) 160’ (max) lineal x 1.2 = equivalent 3” Flexible (SL 45-260) 60’ (max) lineal x 3.33 = equivalent 4” Flexible 160’ (max) lineal x 1.2 = equivalent www.ibcboiler.com SL Series CONDENSING BOILERS SL 80-399 80,000 to 399,000 BTU/H COMMERCIAL CONDENSING BOILER In today’s energy conscious world choosing the right heating system is crucial to maximizing a buildings energy savings and environmental impact. The cost effective solution to any application. Whether the application is a retrofit or new construction combining the SL 80-399 boiler with the flexibility of the Multiplex Racking Systems and IBC’s new touchscreen controller the options available are endless. New Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust Multi boiler communication up to 9.5 million Btuh (24 boilers) without additional controls With 24 boilers turndown ratio is 120:1 = min. firing rate range is 80,000 Btu/h all the way up to 9.5 million Btu/h in 1000 Btu/h increments DDC Control 0-10 VDC or 4-20 mA without additional controls 95.7% Efficiency - CSA 4.9 - 2010 Optional 316 Ti titanium heat exchanger Built-in 4-load priority management and switching 23.4 - 117 CSA Output - MBH 77 - 382 CSA Output - KW 22.6 - 112 Combustion Efficiency (CSA 4.9—2010) 95.7% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 Power (120Vac/60Hz) - Watts @ full fire - Watts ( without pumps) 345 Weight (empty) - lbs/Kg 240 / 110 Pressure vessel water content – USG/Liters 7 / 26 Max boiler flow rate - USgpm 45 Min boiler flow rate - USgpm 20 Max operating pressure - psig 80 Min water pressure - psig 8 Approved installation altitude - ASL 0 - 12,000 ft Ambient temperature - Low (°F/°C) 32°F / 0°C Ambient temperature - High (°F/°C) 122°F / 50°C Max relative humidity (non-condensing) 90.00% Min water Temperature (°F/°C) 34°F / 1°C Max water Temperature (electronic-limit) (°F/°C) 190°F / 87.7°C Max water Temperature (mechanical hi-limit) (°F/°C) 200°F / 93.3°C Max Δ T - supply / return (electronic fence) 40°F reset control 4” 200' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Industry leading turndown ratio of 5:1 outdoor temperature 80 - 399 CSA Input (Natural Gas or Propane *) - KW Maximum equivalent vent length, each side DHW opt out priority for multi boiler systems Built-in SL 80-399 CSA Input (Natural Gas or Propane *) - MBH Ships with 30psi relief valve of water Exhaust pipe size Maximum equivalent length Venting up to 400 feet Sched.40; Rigid PPs 4” 200’ Various Multiplex Racking & rack only options 90° long sweep elbow Allow 8’ equivalent 90° vent elbow Allow 5’ equivalent 45° elbow Allow 3’ equivalent PPs 87-90° elbows Allow 8’ equivalent available Flexible PPs 4” Flexible 160’ (max) actual lineal x 1.2 = equivalent www.ibcboiler.com SL Series Specifications Menu Express Setup Load Status User Setup Installer Setup Diagnostics Back IBC 04:30 ADVANCED CONTROL TECHNOLOGY At IBC we are dedicated to finding new and better ways to provide superior comfort and fuel savings to our customers. We are pleased to announce that all IBC boilers in the SL & VFC Series will be equipped with our new Touch Screen Boiler Controller featuring the latest in advanced touch screen technology and software features. V-10 TOUCH SCREEN CONTROLLER Available in all VFC & SL Series Boilers IBC CONTROL AT YOUR FINGERTIPS Building on the success of our 5 button boiler control launched in 2003, the new touch screen control makes it even easier to setup and monitor your IBC Boiler. With intuitive features like Express Setup, Easier Diagnostics & Intuitive Alert System with plain English Warnings & Error Messages your VFC or SL Series boiler has never been easier to use interface than ever before. EXPRESS SETUP Program your boiler in seconds with an interview style quick start menu User friendly interface for contractor and home owner COMPLETE REMOTE ACCESS Built in internet connectivity. Monitor your boilers operation in real time from your PC/ Mac Remote monitoring & diagnostics TRUE NATIVE BACnet Seamlessly integrate IBC BACnet enabled boilers into your current building automation system MORE FLEXIBILITY Intuitive alert system with warnings & error messages plain Home Page Screen Main Menu Express Setup Load combining features Immediate input feedback Color coded error notifications English Ability to manage up to 4 different loads and 5 pumps Build in alarm notification relay Automatic altitude adjustment Pre programmed values for all load types www.ibcboiler.com Controls EASY USB PROGRAMMABILITY USB Port for emailing of software updates and multi boiler setup HC 13-50 13,500 to 51,000 BTU/H HC 23-84 23,000 to 84,000 BTU/H 29,000 to 106,000 BTU/H HC 33-160 HC 33-124 33,000 to 124,000 BTU/H HC 29-106 33,000 to 160,000 BTU/H CONDENSING BOILERS Introducing IBC’s smallest ever boiler, the HC series begins with the HC13-50 offering the solution for todays better insulated buildings. With onboard full outdoor reset and a slim boiler room footprint the HC Series offers great value for money without sacrificing reliability. Unique and innovative single pass copper heat exchanger, ensuring greater efficiency and eliminating water side corrosion Up to 95% AFUE, with full ASME rated vessel Built in boiler pump 2” & 3” venting options available Contractor friendly, easy to install, maintain Specification HC 13-50 HC 23-84 HC 29-106 HC 33-124 HC 33-160 Fewer parts ensuring greater reliability CSA Input (Natural Gas or Propane) – MBH 13.5 – 51 23 – 84 28.5 – 106 33 – 124 33 – 160 CSA Input (Natural Gas or Propane) – KW 3.95 – 14.94 6.7 – 24.9 8.4 – 31.0 9.7 – 36.3 9.7 – 46.9 Outdoor reset technology increases efficiency CSA Output – MBH 12.4 – 45.4 21 – 79 26 – 99 31 – 115 30 – 149 CSA Output - KW 3.64 – 13.3 6.3 – 23.0 7.8 – 28.9 9.0 – 33.8 9.0 – 43.6 A.F.U.E 95.00% 94.00% 94.00% 94.00% 94.00% Min Gas Pressure (Nat. Gas or Propane) – inch w.c. 5 5 5 5 5 Max Gas Pressure (Nat. Gas or Propane) – inch w.c. 14 14 14 14 14 Power (120Vac/60Hz) - Watts @ full fire with internal pump 126 126 128 130 164 Weight (empty) – lbs/Kg 85 / 39 85 / 39 85 / 39 85 / 39 85 / 39 Pressure Vessel water content – USG/Liters 0.37/1.4 0.37/1.4 0.37/1.4 0.5/1.9 0.5/1.9 Max boiler flow rate - USgpm 9 9 10 11 11 Min boiler flow rate - USgpm 2 2 3 3 3 Max Operating Pressure – Space Heating Coil - psig 43.5 43.5 43.5 43.5 43.5 Approved installation altitude - ASL 12,000 ft 12,000 ft 12,000 ft 12,000 ft 12,000 ft Ambient Temperature – Low (°F/°C) 32/0 32/0 32/0 32/0 32/0 Ambient Temperature – High (°F/°C) 122/50 122/50 122/50 122/50 122/50 Max relative humidity (non-condensing) 90.00% 90.00% 90.00% 90.00% 90.00% Min water Temperature - Space Heating (°F/°C) 50/20 50/20 50/20 50/20 50/20 Max water Temperature – Space Heating (°F/°C) 194/90 194/90 194/90 194/90 194/90 Max equivalent vent length 3" (each side) 120' 120' 120' 120' 120' Max equivalent vent length 2" (each side) 35' 35' 35' 35' 35' by lowering the water temp automatically 10 year limited warranty Reset heating - Set point - DHW Includes Air Vent, Outdoor Sensor & Relief Valve Exceptional value Better reliability and durability www.ibcboiler.com HC Series and service DC 23-84 23,000 to 84,000 BTU/H DC 29-106 33,000 to 124,000 BTU/H DC 33-160 DC 33-124 33,000 to 124,000 BTU/H 33,000 to 160,000 BTU/H DUAL CONDENSING COMBI BOILERS At long last on demand DHW joins the IBC boiler lineup. Combining Domestic Hot Water & Space Heating in a single compact design, the DC Series offers a tried and true heat exchanger design. With the DHW comfort mode, the “cold water sandwich” is eliminated with no moving parts. ASSE 1070 Certified high performance DHW Thermostatic Mixing Valve included Built in Boiler Pump Specification DC 23-84 DC 29-106 DC 33-124 DC 33-160 CSA Input (Natural Gas or Propane) – MBH 23 – 84 28.5 – 106 33 – 124 33 – 160 CSA Input (Natural Gas or Propane) – KW 6.7 – 24.9 8.4 – 31.0 9.7 – 36.3 9.7 – 46.9 CSA Output – MBH 21 – 79 26 – 99 31 – 115 30 – 149 CSA Output - KW 6.3 – 23.0 7.8 – 28.9 9.0 – 33.8 9.0 – 43.6 DHW - CSA Input (Natural Gas or Propane) - MBH 23 - 84 28.5 - 106 33 - 124 33 - 124 DHW - CSA Input (Natural Gas or Propane) - KW 6.7 - 24.9 8.4 - 31.0 9.7 - 36.3 9.7 - 36.3 A.F.U.E 94.00% 94.00% 94.00% 94.00% Min Gas Pressure (Nat. Gas or Propane) – inch w.c. 5 5 5 5 Max Gas Pressure (Nat. Gas or Propane) – inch w.c. 14 14 14 14 Power (120Vac/60Hz) - Watts @ full fire with internal pump 126 128 130 164 Weight (empty) – lbs/Kg 85 / 39 85 / 39 85 / 39 85 / 39 Pressure Vessel water content – USG/Liters 0.37/1.4 0.37/1.4 0.5/1.9 0.5/1.9 Max boiler flow rate - USgpm 9 10 11 11 Min boiler flow rate - USgpm 2 3 3 3 Max Operating Pressure – Space Heating Coil - psig 43.5 43.5 43.5 43.5 Max Operating Pressure – Domestic Hot Water Coil - psig 150 150 150 150 Left and right clearance as low as 1” Approved installation altitude - ASL 12,000 ft 12,000 ft 12,000 ft 12,000 ft Ambient Temperature – Low (°F/°C) 32/0 32/0 32/0 32/0 10 year limited warranty Ambient Temperature – High (°F/°C) 122/50 122/50 122/50 122/50 Max relative humidity (non-condensing) 90.00% 90.00% 90.00% 90.00% Min water Temperature - Space Heating (°F/°C) 50/20 50/20 50/20 50/20 Max water Temperature – Space Heating (°F/°C) 194/90 194/90 194/90 194/90 Min water Temperature – Domestic Hot Water (°F/°C) 104/40 104/40 104/40 104/40 Max water Temperature – Domestic Hot Water (°F/°C) 149/65 149/65 149/65 149/65 Min flow rate to activate DHW heating - USgpm 0.5 0.5 0.5 0.5 Max flow rate DHW heating - USgpm 2.6 3.3 4 4 Max equivalent vent length 3" (each side) 120' 120' 120' 120' 2.7 GPM 3.2 GPM 3.2 GPM Includes Air Vent, Outdoor Sensor & Relief Valve The dual two in one, back to back heat exchanger eliminates the need for a diverter valve and secondary domestic hot water plate heat exchanger Contractor friendly, fewer internal parts, easy to install, maintain and service Reset heating - Set point - DHW Outdoor Reset Technology increases efficiency by lowering the water temp automatically Unique “self learning” ECO-mode for greater DHW efficiencies Domestic Hot Water Delivery: @70° / 39°C temperature rise 2.1 GPM www.ibcboiler.com DC Series 94% AFUE with full ASME rated vessel MULTI-PLEX Racking Designed for the SL 80-399 ENGINEERED ● EASY TO INSTALL ● TURNKEY A Modular system for commercial and multi family installation the Multiplex racking system components fit through standard doorways reducing the need for heavy transport equipment. Our easy to set up boiler networks also provide for precise load matching through wide turndown ratios. SPECIFICATIONS SYSTEM INCLUDES Freestanding inline or back to back options Header sizes include: 3”, 4” or 6” Left or right header connections includes I set of blind flanges Combination from 2 to 12 boilers on one Multiplex racking system Part No. Width "/ mm IN LINE RACK Height " / mm Depth "/ mm 3" Header 2 Boiler In-line 3 Boiler In-line 90-151 70" / 1778 mm 76.25" / 1937 mm 35.5" / 902 mm 90-149 102" / 2590 mm 76.25" / 1937 mm 35.5" / 902 mm 4" Header 2 Boiler In-line 90-159 70" / 1778 mm 76.25" / 1937 mm 35.75" / 908 mm 3 Boiler In-line 90-160 102" / 2590 mm 76.25" / 1937 mm 35.75" / 908 mm 4 Boiler In-Line 90-161 134" / 3404 mm 76.25" / 1937 mm 35.75" / 908 mm 5 Boiler In-Line 90-162 166" / 4217 mm 76.25" / 1937 mm 35.75" / 908 mm 6 Boiler In-Line 90-163 198" / 5030 mm 76.25" / 1937 mm 35.75" / 908 mm 4 Boiler In-line 90-171 134" / 3404 mm 76.25" / 1937 mm 38" / 965 mm 5 Boiler In-line 90-178 166” / 4217 mm 76.25” / 1937 mm 38” / 965 mm 6 Boiler In-line 90-164 198" / 5030 mm 76.25" / 1937 mm 38" / 965 mm 6" Header 8 Boiler In-line 90-165 262" / 6656 mm 76.25" / 1937 mm 38" / 965 mm 10 Boiler In-line 90-166 326" / 8280 mm 76.25" / 1937 mm 38" / 965 mm 12 Boiler In-line 90-176 390" / 9906 mm 76.25" / 1937 mm 38" / 965 mm Flow switches, external sensors optional Low Loss Header options: 3”, 4” or 6” Compact Design: Easy to get into small spaces around existing equipment Low Head Loss—Better flow rates Seismic ratable BACK TO BACK RACK 4" Header 2 + 2 Boiler Back to Back 90-167 70" / 1778 mm 76.25" / 1937 mm 58.5" / 1486 mm 3 + 3 Boiler Back to Back 90-168 102" / 2590 mm 76.25" / 1937 mm 58.5" / 1486 mm 3 + 3 Boiler Back to Back 90-169 102" / 2590 mm 76.25" / 1937 mm 60.5” / 1537 mm 4 + 4 Boiler Back to Back 90-170 134" / 3404 mm 76.25" / 1937 mm 60.5” / 1537 mm 5 + 5 Boiler Back to Back 90-172 166" / 4217 mm 76.25" / 1937 mm 60.5” / 1537 mm 6 + 6 Boiler Back to Back 90-177 198” / 5030 mm 76.25” / 1937 mm 60.5” / 1537 mm 6" Header Rack only options also available SPECIFICATIONS - Racking only Easy 1 day installation Racking Only Part No. Width " / mm Height " / mm Depth” / mm 1 Boiler Rack R-137 38" / 965 mm 76.25" / 1937mm 26.5" / 673 mm Approximate assembly time for 4 x SL 80-399 2 Boiler Rack R-138 70" / 1778 mm 76.25" / 1937mm 26.5" / 673 mm 3 Boiler Rack R-136 102" / 2590 mm 76.25" / 1937mm 26.5" / 673 mm 4 Boiler Rack R-139 134" / 3404mm 76.25" / 1937mm 26.5" / 673 mm 5 Boiler Rack R-140 166" / 4217 mm 76.25" / 1937mm 26.5" / 673 mm 6 Boiler Rack R-134 198" / 5030 mm 76.25" / 1937mm 26.5" / 673 mm 7 Boiler Rack R-141 230" / 5843 mm 76.25" / 1937mm 26.5" / 673 mm 8 Boiler Rack R-142 262" / 6656 mm 76.25" / 1937mm 26.5" / 673 mm x 2 men = 8 Hours www.ibcboiler.com RACKING Pumps: Model - UPS 43-44F Isolation ball valves - Check valves Welded steel headers - Connecting piping Flexible stainless steel connectors Boiler drains - Optional accessories available Multiplex Racking System 30 TO 115 GALLON 30, 40, 50, 60, 80, 115 Gallon INDIRECT WATER HEATERS High performance domestic hot water made of 316L stainless steel. Ships with a domestic hot water sensor ready to communicate with any VFC or SL Series boiler. Durable stainless steel Top connections for easy installation on selected models High out put options & large pipe connections available on selected models High capacity smooth wall coils which are resistant to airlocks Durable high grade 316L stainless steel loss A thermoplastic jacket that will not corrode Optional Honeywell control for additional flexibility and easy service Quality brass ball valve style drain and T+P DOMESTIC WATER BOILER WATER IN/OUT IN/OUT MAXIMUM WORKING PRESSURE (PSI) APPROX. SHIPPING WEIGHT IBC 30 34 23.5 3/4 1 150 85 IBC 40 44 23.5 3/4 1 150 100 IBC 40L 36 28.0 3/4 1 150 100 IBC 50 54 23.5 3/4 1 150 110 IBC 60 62 23.5 3/4 1 150 125 IBC 60L 46 28.0 3/4 1 150 120 IBC 80 56 28.0 1 1 150 140 IBC 115 74 28.0 1 1 150 175 MODEL Fail proof, welded stainless steel dip tube A full 2” of insulation for an extremely low heat PIPING CONNECTIONS NPT DISMETER INCHES HIGH OUTOUT UNITS IBC 80-HO 56 28.0 1 1 150 155 IBC 115-HO 74 28.0 1 1 150 190 IBC 80-HOC 56 28.0 1 1/2 1 1/4 150 155 IBC 115-HOC 74 28.0 1 1/2 1 1/4 150 190 Note: All ratings are based on 180 degree F boiler cold water inlet. For 160 degree F boiler water supply multiply ratings by 0.86. In the interest of continuous improvement, specifications are subject to change without notice. valves are factory installed MAX. FIRST HOUR RATING GAL/Hr @ Conforms to UL STD 174, Certified to CAN/ CSA STD C22.2 No. 110-94 CONTINOUS RATING GAL/HR@ 140F 115F 140F 115F MODEL BOILER OUTPUT REQUIRED BTU/HR) MIN BOILER PRESSURE WATER FLOW DROP THROUGH THROUGH COIL COIL (FT. WATER)) Limited lifetime residential warranty IBC 30 168 223.0 144 200 125,600 14.0 5.3 IBC 40 185 244.0 165 213 134,200 14.0 5.7 Call IBC for special order on storage & buffer IBC 40L 168 2223.0 144 200 125,600 14.0 5.3 IBC 50 201 265.0 163 226 129,900 14.0 6.0 IBC 60 218 286.0 172 240 151,000 14.0 6.2 IBC 60L 200 260.0 154 213 134,100 14.0 5.7 IBC 80 229 293.0 1167 231 145,600 14.0 6.0 IBC 115 274 347.0 186 258 162,400 14.0 6.6 tanks. High outout units IBC 80-HO 332 436.0 270 374 235,600 14.0 9.9 IBC 115-HO 378 488.0 289 400 251,700 14.0 10.5 IBC 80-HOC 351 462.0 289 400 251,700 21.0 15.8 IBC 115-HOC 387 501.0 298 413 259,800 21.0 16.7 www.ibcboiler.com Series SL TANKS Low profile height available for small spaces DIMENTIONS HEIGHT INCHES Condensate Neutralization Tank Part# 180-048 / Refill Kit Part# 180-049 This unit is ideal for neutralizing condensate from condensing boilers. Condensate is acidic and has the potential to harm the environment and the sewer system. This neutralization tank will neutralize the condensate to a neutral pH level before it is discharged to the drain. Neutralized condensate will not corrode drain and sewer systems or harm the environment Fast and easy installation Fully removable lid allowing for ease of service 20 liter (5.3 US gallon) reservoir for large capacity neutralization Comes with initial charge of neutralizing agent Suitable for boiler packages up to 7.0 MBTU 180-048 Condensate Neutralization Tank Intake Air Filters Part# SC-100A: VFC Series, SL 20-115, SL 28-160 Part# P-172: SL 35-199, SL 45-260, SL 80-399 Combustion fan and burner blockages can occur when environmental particulates and foreign matter contaminants (leaves, dust, dandelion & cottonwood fluff, etc.) are drawn into the air intake. In areas where this problem is suspected to be an issue, our optional air intake filter should be installed. Both can be orientated in a variety of positions Easily cleaned by vacuuming or brushing Replacement elements available See our website for more detailed information on Air Filters. P-172 Air Intake Filter mounted directly onto an SL 80-399 boiler www.ibcboiler.com ACCESSORIES New design allows for greater condensate flow while providing superior neutralization APPLICATION DRAWINGS For further application drawings see our website at www.ibcboiler.com www.ibcboiler.com IBC Technologies Inc. (Head Office) 1445 Charles Street Vancouver, BC, Canada V5L 2S7 Tel: 604-877-0277 Fax: 604-877-0295 info@ibcboiler.com www.ibcboiler.com IBC USA 4203 Industrial Court Sheboygan, WI, USA 53083 Tel: 920-783-8340 Better Boilers Fax: 920-783-8339 Nov 2014 All information contained in the brochure is subject to change without notice
© Copyright 2025