Think Inverter. Think Daikin. driving our

Think
Inverter.
Think Daikin.
Inverter ACs from World's No. 1 Air-conditioning Company
driving our
green crusade
The most balanced next-generation
refrigerant
What sets
Daikin apart?
D
aikin is committed to delivering
air-conditioning solutions that enhance
the quality of life all around the world
through application of advanced technology.
A comprehensive range of air-conditioners
with inverter technology that provide comfort
throughout the year is a testament to that. Not
only is our technology shaped by the vision of an
unheralded future but our designs are also carved
to optimise form and function.
In all this, the ability to think and act for the
environment continuously sets us apart. Use
of R-32, the next generation refrigerant, in our
product line-up is one such effort.
Spurring our endeavour to provide comfortable
yet meaningful air-conditioning solutions is a
line-up of superior technology, environmentfriendly products. Browse through our brochure
and discover comfortable yet meaningful airconditioning solutions for your daily comfort.
f txR
Series
Heat Pump
Humidification,
Dehumidification,
Purification &
Ventilation
Comfort
sleep
operation
Inverter
powerful
operation
Available in 0.75, 1.2, 1.5 ton
WALL MOUNTED TYPE (HEAT PUMP) FTXR SERIES
Model Name
Capacity
Power Supply
Running Current
(220-230-240V, 50Hz)
Power
Consumption
COP
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Indoor Unit
Outdoor Unit
Rated (Min - Max)
Rated (Min - Max)
Rated
Rated
(Min - Max)
Rated
Kw
Kw
FTXR28KVMA
RXR28KVMA
2.77 (1.55~3.60)
3.57 (1.30~5.00)
A
A
W
W
W/W
W/W
3.3-3.2-3.1
4.0-3.9-3.8
570 (250~800)
710 (220~1410)
4.86
5.03
Indoor Unit
Front Panel Colour
Airflow rate
Fan Speed
Sound Levels
(H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
(H/SL)
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
FTXR28KVMA
Cooling
Heating
Cooling
Heating
m³/min
cfm
m³/min
cfm
11.1
392
12.4
438
dB (A)
39 / 33 / 26 / 23
41 / 35 / 28 / 25
mm
kg
RXR28KVMA
Type
Cooling
Heating
Cooling
Heating
dB (A)
mm
kg
°CDB
°CWB
m
46/-46/--
FTXR42KVMA
RXR42KVMA
4.20 (1.55~4.60)
5.08 (1.30~5.60)
1 phase, 220-240V, 50Hz
5.4-5.3-5.2
5.9-5.7-5.6
1070 (260~1320)
1170 (220~1600)
3.93
4.34
FTXR42KVMA
White
12.4
438
12.9
455
5 steps, quiet and Automatic
42 / 35 / 27 / 24
42 / 36 / 29 / 26
305 x 890 x 209
14
RXR42KVMA
Ivory White
Hermetically sealed swing type
48/-48/-693 x 795 x 285
48
10°C to 43°C
-20°C to 18°C (Humidify -10 to 24)
10
8
FTXR50KVMA
RXR50KVMA
4.88 (1.55~5.50)
5.91 (1.30~6.20)
7.2-7.1-7.0
7.3-7.2-7.1
1470 (260~1800)
1490 (230~1770)
3.32
3.97
FTXR50KVMA
13.3
470
14
494
44 / 37 / 29 / 26
44 / 38 / 31 / 28
RXR50KVMA
48/-50/--
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.
f txg Series
Heat Pump
Comfortable
mode
Hot start
Intelligent
eye
Available in 0.75, 1.0, 1.4 ton
WALL MOUNTED TYPE (HEAT PUMP) FTXG SERIES
Model Name
Capacity
Power Supply
Running Current
(220-230-240V, 50Hz)
Power Consumption
COP
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Indoor Unit
Outdoor Unit
Rated (Min - Max)
Rated (Min - Max)
Rated
Rated
(Min - Max)
Rated
Kw
Kw
FTXG25JV1BA
RXG25K3V1B
2.5 (1.3~3.0)
3.4 (1.3~4.5)
A
A
W
W
W/W
W/W
3.2-3.0-2.9
4.4-4.2-4.1
560 (350 - 820)
780 (320 - 1320)
4.46
4.36
Indoor Unit
Front Panel Colour
FTXG25JV1BA
Cooling
Airflow rate
Heating
Fan Speed
Sound Levels
(H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)
Cooling
Heating
Max. Piping Length
Max. Height Difference
8.8
311
9.6
339
dB (A)
38 / 32 / 25 /22
39 / 34 / 28 / 25
mm
kg
RXG25K3V1B
Type
Cooling
Heating
Dimensions (HxWxD)
Machine Weight
Operation range
m³/min
cfm
m³/min
cfm
Cooling
Heating
dB (A)
mm
kg
°CDB
°CWB
m
46/43
47/44
FTXG35JV1BA
RXG35K3V1B
3.5 (1.4~3.8)
4.0 (1.4~5.0)
1phase, 220-240V, 50Hz
5.1-4.8-4.6
5.6-5.3-5.1
890 (360 - 1220)
990 (320 - 1500)
3.93
4.04
FTXG35JV1BA
Silver
10.1
357
10.8
389
5 steps, quiet and Automatic
42 / 34 / 26 / 23
42 / 36 / 29 / 26
295 x 915 x 155
11
RXG35K3V1B
Ivory White
Hermetically sealed swing type
48/44
48/45
550 x 765 x 285
34
-10°C to 46°C
-15°C to 20°C
20
15
FTXG50JV1BA
RXG50K3V1B
5.0 (1.7~5.3)
5.8 (1.7~6.5)
7.2-6.9-6.6
7.4-7.1-6.8
1560 (450 - 1880)
1600 (520 - 2500)
3.21
3.63
FTXG50JV1BA
10.3
364
11.4
402
44 / 40 / 35 / 32
44 / 40 / 35 / 32
RXG50K3V1B
735 x 825 x 300
48
30
20
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.
f txs
Series
Heat Pump
3D airflow
mould proof
operation
power
airflow dual
flaps
Available in 0.75, 1.0, 1.5, 1.8, 2.2 ton
WALL MOUNTED TYPE (HEAT PUMP) FTXS SERIES
Indoor Unit
Outdoor Unit
Cooling
Rated (Min.-Max)
Capacity
Heating
Rated (Min.-Max)
Power Supply
Cooling
Running Current
Rated
Heating
Cooling
Rated
Power consumption
(Min.-Max)
Heating
Cooling
COP
Rated
Heating
Model Name
Indoor Unit
Front panel Colour
Airflow rate (H)
Cooling
Heating
m3/min(cfm)
Cooling
Heating
dB (A)
Fan speed
Sound Levels (H/L/SL)
Dimensions (HxWxD)
Machine weight
mm
Kg
Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)
Max. piping length
Max. height difference
A
W
W/W
3.3
4.1
600 (300-800)
830 (290-1,340)
4.17
4.10
FTXS35EVMA
RXS35EBVMA
3.5 (1.2-3.8)
4.0 (1.2-5.0)
FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
RXS50FVMA
RXS60FVMA
RXS71FVMA
5.0 (1.7-6.0)
6.0 (1.7-6.7)
7.1 (2.3-8.5)
5.8 (1.7-7.7)
7.0 (1.7-8.0)
8.2 (2.3-10.0)
1 phase, 230 V, 50Hz
4.7
6.9
8.8
10.4
4.9
7.1
9
11.1
1,020 (300-1,200) 1,550 (440-2,080) 1,980 (440-2,390) 2,360 (570-3,200)
1,080 (290-1,550) 1,600 (400-2,530) 2,040 (400-2,810) 2,520 (520-3,730)
3.43
3.23
3.03
3.01
3.70
3.63
3.43
3.25
FTXS25EVMA
FTXS35EVMA
FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
White
8.7 (307)
8.9 (314)
14.7(519)
16.2(572)
17.4(614)
9.4 (332)
9.7 (342)
16.2 (572)
17.4 (614)
21.5 (759)
5 steps, quiet and automatic
37 / 25 / 22
38 / 26 / 23
44 / 35 / 32
45 / 36 / 33
46 / 37 / 34
37 / 28 / 25
38 / 29 / 26
42 / 33 / 30
44 / 35 / 32
46 / 37 / 34
283 x 800 x 195
290 x 1,050 x 238
9
12
RXS25EBVMA
RXS35EBVMA
Type
Cooling
Heating
dB (A)
Cooling
Heating
mm
Kg
ºCDB
ºCWB
m
m
Dimensions (HxWxD)
Machine weight
Operation Range
Kw
Kw
FTXS25EVMA
RXS25EBVMA
2.5 (1.2-3.0)
3.4 (1.2-4.5)
46 / 43
47 / 44
550 x 765 x 285
34
-15 to 20
20
15
RXS50FVMA
RXS60FVMA
Ivory White
Hermetically sealed swing type
47 / 44
49 / 46
48 / 45
49 / 46
735 x 825 x 300
48
10 to 46
-15 to 18
30
20
RXS71FVMA
52 / 49
52 / 49
770 x 900 x 320
71
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35º CDB; piping length 7.5m.
2. Heating capacity is based on: indoor temp. 20º CDB; outdoor temp.7º CDB, 6º CWB; piping length 7.5m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.
ftKm Series
ˇ
Coanda
airflow
Silver partical
anti-bacterial
filter
Stabilizer free
Available in 0.75, 1.0, 1.5, 1.8, 2.2 ton
WALL MOUNTED TYPE (COOLING ONLY) FTKM SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Rated (Min - Max)
Kw
Power Supply
Running Current
Rated
A
Power Consumption
Rated (Min - Max)
W
COP
Rated (Min - Max)
W/W
Indoor Unit
Front Panel Colour
m³/min
cfm
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
dB (A)
mm
kg
FTKM25PRV16
RKM25PRV16
2.5 (1.0~3.2)
FTKM35PRV16
RKM35PRV16
3.5 (1.0~4.0)
3.07
650 (220~900)
3.85(4.55~3.55)
4.55
964 (220~1300)
3.63 (4.55~3.08)
FTKM25PRV16
FTKM35PRV16
FTKM60PRV16
RKM60PRV16
6.0 (1.0~7.0)
FTKM71PRV16
RKM71PV16
7.1 (2.1~8.0)
7.40
1666(230~2250)
3.60(4.35~3.11)
9.60
2220 (530~3300)
3.20 (3.96~2.42)
FTKM50PRV16
FTKM60PRV16
White
9.6
9.7
17.4
18.1
338
342
614
639
5 steps, quiet and Automatic
37 / 33 / 28 / 25
39 / 34 / 29 / 26
42 / 38 / 35 / 29
45 / 41 / 35 / 31
283 x 800 x 198
310 x 1100 x 239
8
13
RKM25PRV16
RKM35PRV16
Type
dB (A)
mm
kg
°CDB
m
m
FTKM50PRV16
RKM50PRV16
5.0 (1.0~6.0)
1 phase, 230V, 50Hz
5.80
1315(230~1700)
3.80(4.35~3.52)
47 / 43
48 / 44
550 x 765 x 285
33
20
15
RKM50PRV16
RKM60PRV16
Ivory White
Hermetically sealed swing type
47 / 44
49 / 46
595 x 845 x 300
39
10°C to 46°C
30
20
FTKM71PRV16
20.4
720
46 / 42 / 36 /32
RKM71PV16
52 / 49
735 x 825 x 300
49
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35º CDB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a
result of ambient conditions.
f tKP
Series
ˇ
Coanda
airflow
indoor
unit quiet
operation
Stabilizer free
Available in 0.75, 1.0, 1.5, 1.8 ton
WALL MOUNTED TYPE (COOLING ONLY) FTKP SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Rated (Min - Max)
Power Supply
Running Current
Rated
Power Consumption
Rated (Min - Max)
COP
Rated (Min-Max)
Kw
FTKP25PRV16
RKP25PRV16
2.5 (2.0~3.2)
A
W
W/W
3.49
723(480~900)
3.46(4.17~3.55)
Indoor Unit
Front Panel Colour
FTKP25PRV16
FTKP35PRV16
FTKP50PRV16
FTKP60PRV16
RKP60PRV16
6.0 (2.5~6.7)
7.80
1765 (720~2220)
3.40(3.47~3.02)
FTKP60PRV16
White
m³/min
cfm
Airflow rate (Power Chill)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
FTKP35PRV16
FTKP50PRV16
RKP35PRV16
RKP50PRV16
3.4 (2.0~4.0)
5.0 (2.5~5.7)
1 phase, 230V, 50Hz
4.74
6.50
982(480~1310)
1445(710~1750)
3.46(4.17~3.05)
3.46(3.52~3.26)
dB (A)
mm
kg
9.6
338
9.9
17.4
18.1
349
614
639
5 steps, quiet and Automatic
37 / 33 / 28
40 / 36 / 31
45 / 40 / 35
47 / 43 / 38
283 x 800 x 198
310 x 1100 x 239
8
13
RKP25PRV16
Type
dB (A)
mm
kg
°CDB
m
RKP35PRV16
RKP50PRV16
RKP60PRV16
Ivory White
Hermetically sealed swing type
49
50
54
550 x 765 x 285
595 x 845 x 300
33
41
40
19.4°C to 46°C
15
15
15
20
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35º CDB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a
result of ambient conditions.
ftF-P Series
power chill
operation
Titanium appatite econo mode
photocatalytic
aiR purifying
filter
Available in 1.0, 1.5, 1.8* ton
WALL MOUNTED TYPE (COOLING ONLY) FTF - P SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Kw
Power Supply
Running Current
A
Power Consumption
W
COP
W/W
Indoor Unit
Front Panel Colour
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
FTF35PRV16
RF35PRV16
3.35
4.30
931
3.60
FTF35PRV16
m³/min
cfm
9.7
342
dB (A)
mm
kg
39 / 35 / 29
283 x 800 x 205
8
RF35PRV16
Type
dB (A)
mm
kg
°CDB
m
FTF50PRV16
RF50PRV16
5.2
1 phase, 230V, 50Hz
6.60
1,444
49
550 x 765 x 285
37
15
FTF60PRV16*
RF60PRV16*
6.4
8.60
1,882
3.40
FTF50PRV16
FTF60PRV16
White
18.1
20.4
639
720
3 steps and Automatic
44 / 41 / 35
47 / 41 / 35
310 x 1100 x 258
13
RF50PRV16
Ivory White
Hermetically Sealed Rotary Type
50
595 x 845 x 300
41
19.4°C to 46°C
20
10
RF60PRV16
56
43
*Available in 4 star
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35º CDB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as
a result of ambient conditions.
ftC-P Series
programme
dry function
good sleep
off timer
self diagnosis
digital display
remote
Available in 1.0, 1.5, 1.8 ton
WALL MOUNTED TYPE (COOLING ONLY) FTC-P SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Kw
Power Supply
Running Current
A
Power Consumption
W
COP
W/W
Indoor Unit
Front Panel Colour
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
FTC35PRV16
RC35PRV16
3.35
4.60
1,030
FTC35PRV16
m³/min
cfm
9.7
342
dB (A)
mm
kg
39 / 35 / 29
283 x 800 x 205
8
RC35PRV16
Type
dB (A)
mm
kg
°CDB
m
51
550 x 765 x 285
33
15
FTC50PRV16
RC50PRV16
5.22
1 phase, 230V, 50Hz
7.31
1,605
3.25
FTC60PRV16
RC60PRV16
6.40
8.97
1,970
FTC50PRV16
FTC60PRV16
White
18.1
20.4
639
720
3 steps and Automatic
44 / 41 / 35
47 / 41 / 35
310 x 1100 x 258
13
RC50PRV16
RC60PRV16
Ivory White
Hermetically Sealed Rotary Type
54
56
595 x 845 x 300
39
40
19.4°C to 46°C
20
10
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35º CDB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result
of ambient conditions.
ftQ-P Series
smell proof
operation
good sleep
off timer
auto restart
(after power
failure)
Available in 1.0, 1.5, 1.8 ton
WALL MOUNTED TYPE (COOLING ONLY) FTQ-P SERIES
Indoor Unit
Model Name
Outdoor Unit
Capacity
Kw
Power Supply
Running Current
A
Power Consumption
W
COP
W/W
Indoor Unit
Front Panel Colour
Airflow rate (H)
Fan Speed
Sound Levels (H/M/L)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
FTQ35PRV16
RQ35PRV16
3.35
4.90
1,098
FTQ35PRV16
m³/min
cfm
9.7
342
dB (A)
mm
kg
39 / 35 / 30
283 x 800 x 205
8
RQ35PRV16
Type
dB (A)
mm
kg
°CDB
m
51
550 x 765 x 285
33
15
FTQ50PRV16
RQ50PRV16
5.20
1 phase, 230V, 50Hz
7.76
1,705
3.05
FTQ60PRV16
RQ60PRV16
6.40
9.56
2,099
FTQ50PRV16
FTQ60PRV16
White
18.5
20.4
653
720
3 steps and Automatic
45 / 41 / 35
47 / 41 / 35
310 x 1,100 x 258
13
RQ50PRV16
Ivory White
Hermetically Sealed Rotary Type
54
595 x 845 x 300
36
19.4°C to 46°C
20
10
RQ60PRV16
56
40
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27º CDB, 19º CWB; outdoor temp. 35º CDB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result
of ambient conditions.
f tyn
Series
Heat Pump
vertical auto
swing
Saranet filter
PE Anticorrosion
treatment of
outdoor heat
exchanger
Available in 1.0, 1.5, 1.8 ton
WALL MOUNTED TYPE (HEAT PUMP) FTYN SERIES
Indoor Unit
Outdoor Unit
Cooling
Kw
Capacity
Heating
Kw
Power Supply
Cooling
A
Running Current
Heating
A
Cooling
W
Power Consumption
Heating
W
Cooling
W/W
COP
Heating
W/W
Model Name
Indoor Unit
Front Panel Colour
Airflow rate (T/H/M/L/Q)
Fan Speed
Sound Levels (T/H/M/L/Q)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference
FTYN35JXV1
RYN35CJXV1
3.15
3.38
5.10
4.70
1,094
988
2.88
3.42
FTYN35JXV1
Cooling
Cooling
m³/min
cfm
10.5 / 10.1 / 8.4 / 6.9 / 6.4
372 / 355 / 298 / 242 / 225
dB (A)
mm
kg
41 / 40 / 35 / 29 / 28
288 x 800 x 206
9
RYN35CJXV1
Type
Cooling
Cooling
Heating
mm
kg
°CDB
°CWB
dB (A)
540 x 700 x 250
31
m
1. Cooling: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, 24° CWB
2. Heating: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB
3. All units are being tested and comply to ISO 5151 (Non-ducted unit).
12
5
FTYN50JXV1
RYN50CJXV1
5.25
5.28
1 phase, 220-240V, 50Hz
7.19
6.53
1,635
1,490
FTYN60JXV1
RYN60CJXV1
6.01
6.15
8.26
7.99
1,870
1,800
3.21
3.54
3.42
FTYN50JXV1
FTYN60JXV1
White
16.1 / 15.2 / 13.5 / 12.0 / 10.6 18.2 / 17.4 / 15.2 / 13.4 / 11.8
570 / 536 / 478 / 424 / 375
641 / 614 / 537 / 474 / 418
3 steps, Turbo and Quiet
44 / 42 / 39 / 36 / 34
48 / 46 / 43 / 40 / 37
310 x 1065 x 224
14
RYN50CJXV1
Light Grey
Rotary
49
651 x 855 x 328
47
19°C to 46°C
-9°C to 18°C
RYN60CJXV1
52
753 x 855 x 328
50
20
15
Ten Reasons to
Buy Daikin
Air-conditioning
Specialist
Daikin focuses on
air-conditioning solutions
and control systems. As
specialists, it’s all we
do. No wonder Daikin is
recognised as an expert in
air-conditioning.
Pioneer in
Air-conditioners
Daikin has been providing
air-conditioning solutions
for over 12 years in India.
As one of the industry’s
more trusted names, Daikin
air-conditioning equipment
can be found in homes,
offices, hotels and shops.
Daikin is committed to the
air-conditioning market and
has a manufacturing facility
located in Rajasthan.
The Daikin Edge
with in-house
Manufacturing
Daikin is the only company
in the world dedicated
to manufacturing both
air-conditioning systems
and refrigerants. Each
element has been designed
to work flawlessly with the
next - delivering optimal
performance - from the
time a project begins till
the moment of absolute
comfort.
Unmatched
After-sales Support
Year Warranty
on Compressors
Wise Investment –
Low Running Cost
Daikin takes pride in
providing its customers with
efficient after sales support,
including readily available
spare parts warehoused in
India.
Reliability. That’s probably
top of your list when buying
an air-conditioning system
for your home or business.
When you buy a Daikin
air-conditioning system you
need to look beyond the
initial purchase price. It pays
to consider ongoing running
costs in conjunction with the
potential life of the product.
Daikin systems offer superior
build quality and energy
efficiency.
Daikin gives you peace of
mind and reassurance with
their 5-year warranty on
compressors of Split ACs.
That’s how confident Daikin
is about the quality and
reliability of its product.
High Energy
Efficiency
Comprehensive
Range & Quiet
Operation
Daikin’s continuous drive
for improved efficiency has
seen its advanced inverter
technology being applied
to split, ducted and other
systems. These systems
provide a more comfortable
environment and are more
energy efficient when
compared to non-inverter
systems.
Daikin has a comprehensive
range of products in both
domestic and commercial
segments. Designed to
provide effective and quiet
air-conditioning, Daikin can
customise a solution to meet
every requirement.
Experienced
Dealers
Daikin distributes
its products through
experienced dealers. This
ensures that you receive
a top quality product with
expert support. Together
this means the best
air-conditioning solution for
your individual needs.
Environment
Friendly
Daikin continues to work
towards a sustainable
future and has received
Environmental Management
System certification to
ISO14001. Daikin
Air-conditioning India
Pvt. Ltd. is dedicated to
preserving and protecting
the environment through
the production of energy
efficient products.
Terms & Conditions Apply
Humidity control Technology
Function
FTXR
FTXG
FTXR28/42/50KVMA
FTXG25/35/50JV1BA
FTXS25/35EVMA
FTXS
FTXS50/60/71FVMA
FTKM25/35PRV16
FTKM
RXR28/42/50KVMA
RXG25/35/50K3V1B
RXS25/35EBVMA
RXS50/60/71FVMA
RKM25/35PRV16
Swing Compressor & Reluctance DC Motor
Rotary Compressor
PAM Control
Humidifying Operation
Drying Operation
Dry Cooling Operation
Moisturising Operation
Cooling Breeze Operation
Comfortable Mode
Comfortable Airflow
Power-airflow Flap
Power-airflow Dual Flaps
Wide-angle Louvers
Vertical Auto-swing (up and down)
Horizontal Auto-swing (left and right)
3-D Airflow
Comfort Sleep Operation
Hot Start
Coandaˇ Airflow Mode
Comfort Control
Indoor Unit Quiet Operation
Outdoor Unit Quiet Operation
Intelligent Eye
Automatic Operation (Heating and Cooling)
Programme Dry Function
Auto Fan Speed
Temperature & Humidity Level Information Display
ECONO Mode
Lifestyle Convenience
Home Leave Operation
Inverter Powerful Operation
New Powerful Operation (Non-Inverter)
POWER CHILL Operation
Indoor Unit ON/OFF Switch
Child Lock
Multi-coloured Indicator
Monitor Brightness Setting
Fan Only
Filter Cleaning Indicator
Mould Shock Operation
Home Leave Ventilation
Streamer Discharge Air Purifier
Mould-Proof Operation
Cleanliness
Mould Proof Stick
Smell-Proof Operation
Titanium Apatite Photocatalytic Air-Purifying Filter
Option
Air Purifying Operation
Air Supply Filter
Silver Particle Anti-Bacterial Filter
Saranet Filter
Air-purify Filter with Photocatalytic Deodorising Function
Fresh Air Supply Ventilation
Wipe-clean Flat Panel
Timers
24-Hour ON/OFF Timer
Count Up-down ON/OFF Timer
Night Set Mode
Worry Free
Good Sleep Off Timer
Auto-restart (after power failure)
Stabilizer Free
Self-diagnosis (R/C, LED) Display
PE Anti-corrosion Treatment of Outdoor Heat Exchanger
R/C with Back Light
Control
*1
Weekly Timer
Luminescent R/C Button
Indoor temp. Display on R/C
R/C LCD Back Light OFF
*1-Off only, *2-Special Button on remote control
*2
FTKM
RKM50
FTKM
PRV16
FTKM50/60/71PRV16
PRV16
RKM50/60PRV16, RKM71PV16
n
FTKP
5 star
FTKP25/35PRV16 FTKP50/60PRV16
FTF35/50/60PRV16
FTC35PRV16
FTC50/60PRV16
FTQ35PRV16
FTQ50/60PRV16
FTYN35/50/60JXV1
RKP25/35PRV16
RF35/50/60PRV16
RC35PRV16
RC50/60PRV16
RQ35PRV16
RQ50/60PRV16
RYN35/50/60CJXV1
Option
Option
Option
Option
Option
Option
Option
Option
RKP50/60PRV16
Option
Option
*2
*2
Option
*2
Option
Option
3 star
2 star
FTYN
12th Floor, Building No. 9, Tower A, DLF Cyber City, DLF Phase III, Gurgaon - 122 002, Haryana, India.
Tel.: 0124-4555444, Fax.: 0124-4555333, e-mail: ho@daikinindia.com
Follow us on:
www.facebook.com/daikinindia
Jaipur: 0141-2223215, 2225569
Kolkata: 033-22894259/60
Lucknow: 0522-2787307/340/291
Mumbai: 022-30926666
Pune: 020-25560300
www.twitter.com/daikinindia
Service toll free
1800-102-9300, 1800-22-9300
cs@daikinindia.com
Visit us at www.daikinindia.com
www.daikinindiablog.com
As a continuing policy of product innovation at Daikin, the design and specifications are subject to change without prior notice. The visuals of the products in the catalogue are representative only, actual
products might differ from the ones shown.
Sales revenue includes revenue through sales of all Daikin Air-conditioning Systems. World’s no.1 position based on internal assessment of total sales revenue for 2012/13.
World’s no.1 position based on internal assessment of total company sales revenue for 2012/13.
“Products mentioned in this catalogue comply with RoHS regulations as per E-waste (Management & Handling) Rules, 2011 and should not be mixed with general household waste at the end of their
useful life. For more details kindly visit our website www.daikinindia.com or contact our customer care centre at 1800 102 9300 / 1800 22 9300.”
DAIPL-2014/14-RA20-2A
Ahmedabad: 079-26583013/14, 36583364
Bengaluru: 080-25590452-54
Chandigarh: 0172-5089862-64
Chennai: 044-24314210-15
Delhi-NCR: 011-26385924-27
Hyderabad: 040-39134289/93