Operation and Maintenance Schedule Overview of O&M projects and new installations 1 January – 31 December 2017 Sag 15/18069 Introduction According to the Rules for Gas Transport version 16.0, section 10.1 c, Energinet.dk shall provide information on scheduled repair and maintenance activities in relation to the gas transmission system. This document describes all scheduled activities from 1 January - 31 December 2017. Shippers who will be affected by activities with an effect on Energinet.dk’s transport capacity will be contacted directly. For further information please contact: Helle Øgaard (HOG@energinet.dk) på tlf. 23 33 89 40. Henrik Bay (hby@energinet.dk) på tlf. 30 92 30 62 Updated: 2. january 2017 Version 1 Sag 15/18069 Color code: Ll. Torup Gas storage Stenlille Gasstorage Transmission systemet Egtved Compressor station Nybro Gastreatment plant 2017 Periode Start Week Date 1 1 5 6-20 10 10 02-jan 02-jan 01-feb 06-feb 07-mar 07-mar End Activities Consequences Compressor Station: Service on help equipment No consequences M/R stationer: Exterior tank inspection number: 61 No consequences Frøslev - Egtved I: Tie-in at Bevtoft. Reduced pressure RTU replacement on MR & LV stations stations No signal from the communication from station to KCG in the replacement period for each station (typically 1-2 hours). There will be technicians at the station during this time M/R Middelfart: Inspection of inner surface of tanks on filter and preheater Supply of cold gas for approx. 8 hours. M/R Billesbølle: Inspection of inner surface of tanks on filter and preheater Supply of cold gas for approx. 8 hours. M/R Koelbjerg: Inspection of inner surface of tanks on preheater No consequences. The grid can be supplied from M/R Højby Compressorstation conversion of Main Terminal Box 3 Compressorstation - IS 3 checking the condition of Noreva valve Compressor 3 is not available for 14 days IS 3 will not be available during this period Flow velocity between 1.5 to 2 m / s from Egtved against Nyborg v / pigging with "MFL" Date 22-dec 22-dec 28-feb 15-maj 04-aug 04-aug 10 07-mar 04-aug 13 27-mar 07-apr 13 29-mar 29-mar 14 03-apr 07-apr Lillebælt S: Data Logger inspection Sag 15/18069 14 03-apr 01-sep 14 03-apr 01-sep 14 03-apr 01-sep 14-15 15 03-apr 09-apr 12-apr 17-jun 18 01-maj 02-okt 18 01-maj 02-okt 18-22 01-maj 02-jun 19 08-maj 19-maj 20 16-maj 20-maj 22 30-maj 03-jun 24 12-jun 10-nov 25 20-jun 20-okt 25 21-jun 21-okt 25 21-jun 21-okt 25 23-jun 23-okt 32 08-aug 08-nov 33 17-aug 17-nov 33 18-aug 18-nov 33 14-aug 18-aug Sag 15/18069 M/R Ullerslev: Inspection of inner surface of tanks on filter and preheater M/R Dragør: Inspection of inner surface of tanks on filter and preheater M/R Dragør Border: Inspection of inner surface of tanks on filter and preheater Condenser E2203 renovering M/R Måløv "1": Pipe work Supply of cold gas for approx. 8 hours. Supply of cold gas for approx. 8 hours. Supply of cold gas for approx. 8 hours. Reduced H2S treatment (225.000Nm3/h) No consequences M/R Sorø:Inspection of inner surface Supply of cold gas for approx. 8 hours. of tanks on filter and preheater M/R Lynge: Inspection of inner surface of tanks on filter and preheater Process train 1 - container inspection Compressorstation conversion of Main Terminal Box 1 Supply of cold gas for approx. 8 hours. 50% treatment capacity (225.000Nm3/h) Compressor 1 is not available for 14 days M/R Sorø: Change of boiler No consequences. The grid can be supplied from other M/R stations and can be closed down in the summertime. M/R Li. Selskær: Change of boiler Supply of cold gas for approx. 4 hours. Monday and Tuesday. M/R Brande: Inspection of inner surface of tanks on filter and preheater M/R Nyborg: Inspection of inner surface of tanks on filter and preheater Supply of cold gas for approx. 8 hours. Supply of cold gas for approx. 8 hours. M/R Torslunde: Inspection of inner surface of tanks on filter and preheater No consequences. The grid can be supplied from other M/R stations and can be closed down in the summertime. M Skærbækværket: Inspection of inner surface of tanks on filter No consequences M/R Vallensbæk: Inspection of inner No consequences. The grid can be surface of tanks on filter and supplied from other M/R stations and preheater can be closed down in the summertime. M/R Brøndby: Inspection of inner surface of tanks on filter and preheater M/R Ringsted: Inspection of inner surface of tanks on filter and preheater M/R Slagelse: Inspection of inner surface of tanks on filter and preheater Supply of cold gas for approx. 8 hours. Supply of cold gas for approx. 8 hours. Supply of cold gas for approx. 8 hours. Supply of cold gas for approx. 4 hours Monday and Tuesday Nybro total ESD testing (Tyra and Syd Arne terminal) 34 35 28-aug 01-sep 35 28-aug 01-sep 35 28-aug 01-sep 36 04-sep 29-sep M/R Brande: Change of boiler and possible NewTech Supply of cold gas for approx. 4 hours Monday and Tuesday Compressor 1,2,3,4 will periodically be Compressor Station - Boroscopic unavailable - Coordinated with KCG for inspection of compressor 1,2,3,4 smooth running Compressor station - MAN Motor Compressor 1,2,3,4 will periodically be Winding High Voltage Test of unavailable - Coordinated with KCG for kompressor 1,2,3,4 smooth running Compressor train 1,2,3,4 will periodically be unavailable Compressor station - MAN Level 2 Coordinated with KCG for smooth Service of kompressor train 1,2,3,4 running so that two compressors always available M/R Karlslunde: Inspection of inner surface preheater 39 26-sep 22-dec 39 28-sep 28-dec 40 02-okt 31-dec 44 30-okt 45 06-nov 45 06-nov Sag 15/18069 Flow Stop 6 hours start-up time 2 hours M/R Køge: Inspection of inner surface of tanks on filter and preheater M/R Højby: Inspection of inner surface of tanks on preheater No consequences. The grid can be supplied from other M/R stations and can be closed down in the summertime. Supply of cold gas for approx. 8 hours. No consequences. The grid can be supplied from other M/R stations Flow velocity between 1.5 to 2 m / s Li. Torup - Ålborg: Intelligent pigging, from Li. Torup to Ålborg v/pigging med (MFL og calliper) 03-nov "MFL" Flow velocity between 1.5 to 2 m / s Taulov - Skærbækværket: Intelligent from Taulov to Skærbækværket pigging, (MFL og calliper) 10-nov v/pigging med "MFL" Flow velocity between 1.5 to 2 m / s Torslunde - Lynge: Intelligent pigging, from fra Torslunde to Lynge v/pigging (MFL og calliper) 10-nov med "MFL"
© Copyright 2025