COME TO LIFE residential design guidelines Version 4 issued December 2014 COnTents Welcome home 3 1. INTRODUCTION 4 1.1 The Design and Approval Process 4 1.2 Information Required 4 1.3 Time Limits 4 4. VEHICLE ACCESS TO ALLOTMENTS and Position of Crossovers 8 4.1 Driveway Location 8 4.2 Driveway Width 8 4.2.1 East Parkway Allotments 8 4.3 Crossover Width and Materials 8 1.4 Encumbrance Manager Contact Details 4 5. STREET APPEARANCE 1.5 Design and Approval Process 4 5.1 Front Facade 9 5.2 Corner Facade 9 2. SUSTAINABILITY and THE ENVIRONMENT 5 2.1 Energy Rating of Homes 5 2.2 Energy Efficiency 5 2.3 Water Conservation – Tanks 5 2.4 Environmental Protection – Trees 3. HOME SITING and SIZING 5 6 9 13 6.1 Side and Rear Boundary Fencing 13 6.2 Front Boundary Fencing 14 6.3 East Parkway Allotments 14 6.4 Fencing Adjacent to Reserves 14 6.5 Landscaping Front Gardens 7. LIVING AT BLUESTONE 15 15 7.1 Recreational/Commercial Vehicles 15 15 5.3 Walls 10 7.2 Maintenance 5.4 East Parkway and Park Frontage Allotments 10 8. terrace home guidElines19 5.5 Roof Materials and Form 11 5.6 Garages and Carports 11 5.7 Domestic Outbuildings 12 Residential Design Guidelines – Appendix34 5.8 Clotheslines and Letterboxes 12 3.1 Building Envelope Plans 6 5.9 Air Conditioners 12 3.2 Privacy 6 5.10 Signage 12 3.3 Number, Size and Location of Vehicle Parking Spaces 6 5.11 NBN Velocity 12 3.4 Siteworks – Cut and Fill 6 5.12 Roof Attachments (including Antennae and Satellite Dishes) 13 3.5 Siteworks – Retaining Walls 6 *Where design discrepancies occur between neighbours using differing versions of the Residential Design Guidelines, the decision of the Encumbrance Manager will be final. 2 6. FENCING w h 30 MINUTES TO THE CBD welcome home The 100 hectare development includes over 16 hectares of public open space with over 4 kilometres of pathways and has been developed to ensure the character of Mount Barker is incorporated wherever possible. At Bluestone we believe good design is essential for good living. After consulting Adelaide’s best town planners and home builders we have developed these Residential Design Guidelines to ensure this is achieved. They will: Help you choose a house and lot that suits your requirements Give owners and builders greater certainty about the character and quality of homes within Bluestone with an aim to preserve property values and optimise the living fabric of Bluestone Maintain flexibility and individuality to create your own home Establish safe streetscapes and neighbourhoods that encourage community creation Help the approval process with the District Council of Mount Barker Encourage preservation of the natural environment Protect the integrity of your community’s streetscapes and function 3 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Bluestone is a prestigious and highly sought after new residential community at Mount Barker situated just 30 minutes drive from Adelaide CBD. 1. introduction 1.1 THE DESIGN and APPROVAL PROCESS As the Residential Design Guidelines form part of the Encumbrance attached to the Certificate of Title on all allotments purchased, it is very important that you comply with them. Similarly, prior to seeking Council approval for all dwellings, outbuildings, landscaping of front yards and other structures detailed in these Guidelines, you will also require an Encumbrance Approval. Please note: You will need to pay the Encumbrance Management Fee that’s set out in the Encumbrance Approval Application Form (see Appendix) before your application is considered and processed. 1.2 INFORMATION REQUIRED You’ll find details of all the information that’s required when submitting a new dwelling application for approval to the Encumbrance Manager in the Encumbrance Approval Application Checklist (see Appendix). Please note: Under the terms of the Encumbrance, the Encumbrance Manager or agent has the right to apply and enforce the Residential Design Guidelines at their discretion and to vary any requirements of these Guidelines. 1.3 TIME LIMITS You must lodge your house plans with the Encumbrance Manager no later than 18 months after settlement of the purchase of your allotment. Similarly, you will need to commence construction, or at least have laid the footings or foundations of your home – no later than 24 months after settlement. Once your submitted plans have been approved by the Encumbrance Manager, they will be stamped and returned to you. 4 Please note: You should not submit your plans to the District Council of Mount Barker for assessment against the Development Act 1993 until they have been approved and stamped by the Encumbrance Manager. 1.4 ENCUMBRANCE MANAGER CONTACT DETAILS The Encumbrance Manager’s contact details are: Amanda Price CIC Australia c/-2 City View Boulevard, Northgate SA 5085 Email: amanda.price@cicaustralia.com.au Ph: 8261 1888 1.5 DESIGN AND APPROVAL PROCESS Here is the process you should follow to ensure the plans for your new home at Bluestone meet the Design Guidelines. 1. READ THE RESIDENTIAL DESIGN GUIDELINES Please carefully read the Residential Design Guidelines and familiarise yourself with the requirements for building on your allotment. You should also obtain a copy of your Building Envelope Plan from the Encumbrance Manager to see if there are any specific provisions for your particular site. 2. PRELIMINARY DESIGN (OPTIONAL) It’s a good idea to first identify the features and opportunities of your site. You should also take into account where North is located when considering the layout of your home and courtyards. Work with your architect or builder to prepare a preliminary site and house plan. This can be a simple sketch, rough layout or copy of a builder’s house plan that you would like to build on your site. Discuss your preliminary site and house plan with the Encumbrance Manager who can help you to address any matters in the Guidelines prior to undertaking final design. This preliminary design input is highly recommended for corner allotments. 3. PREPARE DESIGN 4. APPLICATION Prepare and submit your application form to the Encumbrance Manager, including the Encumbrance Application Checklist together with your house and landscape design plans for approval (see section 1.2 for the information required). You should allow 10 working days for the Encumbrance Manager to confirm that the application is acceptable or advise you of any items that require further consideration. 5. ENCUMBRANCE APPROVAL Once approved by the Encumbrance Manager, the plans will be stamped accordingly and forwarded to the applicant, builder, owner and Council. 6. COUNCIL APPROVAL Lodge your stamped plans for Development Approval with the District Council of Mount Barker, together with the information described in the planning consent checklist provided in the Appendix of these Guidelines. Once Development Approval has been issued by the Council you may commence building your home. 7. CONSTRUCTION You need to commence the construction of your home no later than 24 months after settlement. 8. INSPECTION During construction, and once construction is completed, the Encumbrance Manager may inspect the works to check that it complies with the approved plans 2. sustainability and the environment In accordance with State Government requirements, all dwellings must achieve a 6-Star Energy Rating. This rating is important in order to reduce the energy consumption, greenhouse gas emissions, and ongoing costs of your home. 2.2 ENERGY EFFICIENCY REQUIREMENTS: Gas water heating (or solar hot water system with gas backup) and a gas cook top are to be installed If a solar hot water system is to be used; – It should be a split system with the tank located within the roof space or on the ground – The solar collector panels should be located so that they are not highly visible from any public street or thoroughfare. Where visible from public areas, solar panels will be assessed on their merits with regard to scale, form and colour: and – In addition, solar collector panels should be supported on the roof and not on a separate frame 2.3 Water Conservation – Tanks REQUIREMENTS: A minimum of a 1,000 litre capacity rainwater tanks required to be installed and be plumbed to a toilet, water heater and/or to all cold water outlets in the laundry of the dwelling The maximum height of any tank is 2.4 metres All tanks must be hidden from public view either by a screen or a side fence return Please note: This rainwater tank is in addition to a State Government requirement for a 2,000 litre tank for fire-fighting purposes. The minimum total storage capacity is 3,000 litres. 2.4 Environmental Protection – Trees The Building Envelope Plan for your property identifies Tree Protection Zones (TPZ) that may contain significant trees that must be protected during construction, and Built Form Setbacks (BFS) that must be adhered to in the design and construction of your home. Any development, including buildings, earthworks (excavation, trenching, fill and compaction) and hard surfacing (paving or concreting) within the Tree Protection Zone (TPZ) can impact on the long-term stability and health of the tree and should generally not occur. Some encroachment into a TPZ may be permitted subject to assessment by an appropriately qualified Arborist and approval from the Encumbrance Manager and the Council. Any development adjacent to a TPZ will generally not be permitted if it encroaches more than 10% of the zone. No encroachment into the BFS is permitted. REQUIREMENTS: You may not remove or prune a significant tree without prior approval of the Encumbrance Manager and Council A fence or barrier must be erected around the Tree Protection Zone prior to, and during, construction the Tree Protection Zone must be mulched Non-complying example of rainwater tank – neither screened from public nor set back Complying example of rainwater tank size and location 5 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES 2.1 ENERGY RATING OF HOMES 3. home siting 3.1 BUILDING ENVELOPE PLANS 3.2 PRIVACY When you purchase your lot, you will be provided with a Building Envelope Plan. If you require a replacement Building Envelope Plan, please contact the Encumbrance Manager. It is important that your home is constructed in a way that respects your neighbours’ privacy. REQUIREMENTS: To minimise the opportunity to directly overlook another property’s room windows and private open spaces the following should be provided to all upper level habitable room windows, external balconies, terraces and decks; The dwelling and associated garage must be contained within the ‘Building Envelope’ depicted on this plan. Please note: The following may encroach beyond the setbacks referred to in these guidelines; Fascias, gutters, downpipes and eaves up to 45 centimetres (450 millimetres); Masonry chimneys, flues and pipes; Unroofed balconies, landings, steps or ramps not more than 1 metre in floor level height. If you have purchased a corner allotment, the ‘primary street frontage’ is defined as the frontage having the lesser length, and the ‘secondary street frontage’ is the frontage having the greater length, but not including a rear lane. 6 REQUIREMENTS: Permanently fixed translucent glazing in that part of the window below 1.7 metres above floor level Window sill heights of a minimum of 1.7 metres above floor level; or Permanently fixed external screens, including wing walls, solid or translucent panels and planter boxes to restrict site lines 3.3 N umber, Size and Location of Vehicle Parking Spaces REQUIREMENTS: Each detached dwelling should provide two on-site parking spaces, one of which is undercover (the second parking space can be tandem) Uncovered car parking spaces should measure at least 5.5 metres by 3 metres Garages and carports must be set back at least 1 metre from the main façade/building line of the associated dwelling REQUIREMENTS: The maximum cut or fill allowed on a site is 1.5 metres relative to the existing natural ground level (see sketch below) Any exposed areas below the finished floor level should be screened by landscaping or appropriate physical screening Embankments should have a maximum grade of 1-in-4 and be suitably landscaped to protect the embankment from erosion (see sketch below) 3.5 Siteworks – Retaining Walls REQUIREMENTS: If your retaining wall is visible from public areas; It should have a maximum height of 1 metre Where retaining of land greater than 1 metre in height is necessary, the retaining wall should be tiered, with a minimum distance of 1 metre between the tiered retaining walls to be used for landscaping (see Sketch 1) Sketch 1 A combined retaining wall and fence located on the boundary of a public road or reserve must not exceed2.5 metres in height, comprised of a maximum 1 metre retaining wall, and fence (see Sketch 2) The maximum height for any retaining wall and fencing that is not combined and is located on the boundary of a public road or reserve is 2.8 metres, comprised of a maximum 1 metre retaining wall, and 1.8 metres fence that is offset by 1 metre and landscaped (see Sketch 3) Sketch 2 Sketch 3 7 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES 3.4 Siteworks – Cut and Fill If your retaining walls are not visible from public areas; Retaining walls on boundaries shared with neighbouring properties require the written approval of the relevant neighbouring owner(s). Where approval is not given, no retaining wall may be constructed on the relevant boundary In rear private yards (other than those visible from public areas such as reserves) combined retaining walls may be increased to a maximum height of 1.5 metres subject to the agreement of both neighbours 8 All retaining walls, whether visible from public areas or not, (other than those constructed by the Developer) should be constructed of the following approved materials: Stone Quarry/moss rock ‘Allen Block’ or similar block walling ‘Kensington’ concrete sleepers; or Rendered masonry 4. VEHICLE ACCESS TO ALLOTMENTS and position of crossovers 4.1 Driveway Location 4.2 Driveway Width REQUIREMENTS: REQUIREMENTS: Where included on Building Envelope Plans, driveways are required to be located in the positions shown Driveways should; Only one crossover is allowed per street frontage Have a maximum width of 4 metres for single driveways and 5 metres for double driveways as measured at the front property boundary (see figure below), and Be set back 1 metre from the side boundary 4.3 C rossover Width and Materials REQUIREMENTS: Crossovers should be a maximum width of 6 metres Crossover materials are required to be the same as those of the footpath located within the street, and conform to the existing paving layout within stretcher bond pattern plus header courses (see photos below) Please note: The owner is responsible for ensuring that the footpath alignment is not altered The owner of the property is responsible for ensuring that footpaths and crossovers damaged during building construction are reinstated to their original condition Please note: For the purpose of these guidelines; An ‘invert’ is the point where the ‘crossover’ adjoins the kerb line of the roadway A ‘crossover’ is that part of the driveway constructed between the kerb line and the private property boundary; and 4.2.1 EAST PARKWAY ALLOTMENTS The owner of the property is responsible for ensuring that an equivalent tree replaces any street tree damaged during building construction. REQUIREMENTS: There will be no vehicle access from East Parkway where alternative access is provided Complying – continuous footpath and matching crossover Non-complying – driveway disrupts footpath 9 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES A ‘driveway’ is that part of the vehicle access located within the private property (see sketch above). 5. Street appearance 5.1 Front Facade 5.2 corner facade To maintain the character of this residential community, the front façade of your home should be enhanced through architectural detailing and the articulation of walls. Bulky, bland façades are to be avoided. Dwellings constructed on corner/ reserve lots, as defined in the Building Envelope Plan, must be designed to address the primary frontage and any secondary frontages including roads, reserves or public open space. The use of verandahs, porticos, feature windows and other design features that complement the front elevation will be required. Window treatment to the secondary street/reserve frontage must correspond with the windows of the main facade. REQUIREMENTS: Dwellings are to include a verandah or porch/portico element plus one of the following architectural design elements; Architectural features for windows such as bay or box windows Single storey front facade with verandah, bay window and gable The corner/reserve treatment must return around the corner by a minimum of two rooms, or at least 8 metres. Additionally, two storey homes on corner lots must have all upstairs windows which face the secondary frontage to match the primary frontage windows. Head and sill heights must match with consideration to the vertical alignment of windows over both levels. You are not permitted to have blank walls facing the corner/reserve frontage. Fixed window shade treatments Window mouldings (e.g. Unitex or rendered banding) Gable or Dutch gable Blade wall Balcony form projecting from the façade. Architectural features for roof forms, such as skillion roof form or eave, overhang 900 millimetres or greater Raised portico roof Varied floor levels (visible to street elevation) House that does not have a minimum of two of the design elements prescribed in the guidelines Please note: Other architectural design elements will be assessed on their individual design merit. Example of elements for a dwelling on a corner allotment 10 Dwellings and outbuildings should be clad in materials that minimise glare and reflection, blend with the natural environment and minimise the visual obtrusiveness of buildings and structures. 5.4 EAST PARKWAY AND park frontage ALLOTMENTS Dwellings located on East Parkway (i.e. having a boundary on East Parkway); – Must be orientated so that the front of the dwelling addresses East Parkway (i.e. front door with portico/verandah feature and associated windows must face East Parkway) and the vehicle access is from an alternative road (rear access) – The rear elevation (i.e. the elevation facing the ‘rear’ access road) of the dwelling, including garages and carports, must also present an attractive and varied building elevation to achieve an attractive streetscape (i.e. second front door with portico/verandah feature and associated windows that match the East Parkway primary frontage) REQUIREMENTS: Example of single storey corner dwelling with face brickwork, stained timber windows and verandah extending to secondary elevation Dwelling elevations visible to the public (including the secondary frontages of all dwellings on corner allotments) must include windows and at least two of the following elements (in colours consistent with those contained in Appendix); Face brickwork Render Stone or veneer stone Feature panels including; – Selected Hardies products such as Linea or Scyon Corner house that does not address the corner frontage as prescribed in the guidelines – Mini-orb – Panels with expressed joints – Timber panelling Stained timber windows or commercial section aluminium windows On allotments that share a boundary with a public reserve; – Dwellings must present an attractive and varied building elevation to the public reserve – Internal living areas should be located on the side of the house facing the public reserve – Utility rooms such as bathrooms and laundries must be located so that they are not visible from public areas – Service items such as clotheslines, garden sheds, external heating and cooling units, hot water systems etc. must be located and screened from public view (i.e. not visible from the public reserve) Metal, timber or glass balustrades Metal or timber louvres/privacy screens Two different but complementary colours of rendered walling Vertical articulation (two storey buildings) Other architectural elements at the discretion of the Encumbrance Manager Example of elements for two storey dwelling on corner allotment 11 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES 5.3 Walls 5.5 Roof Materials and Form 5.6 garages and carports REQUIREMENTS: REQUIREMENTS: Roof materials are required to be selected from pre-coated corrugated steel, tiles, slate or cement shingles (flat) Roof form and pitch, building materials and detailing for garages and carports are required to conform to the same predominant materials used in the construction of the walls and roofs of the associated dwelling A roof form providing articulated shapes is required and, where appropriate, the use of dormers, verandahs, porticos, balconies or other decorative architectural elements are also encouraged All roofs must include eaves of a minimum width of 450 millimetres Pitched roofs are required to be constructed with a minimum pitch of 25 degrees. Flat, contemporary roof forms will be considered subject to design merit All supports to carports should be of substantial size (90 millimetres x 90 millimetres or a minimum 90 millimetres diameter) Double garage or carport doors should; – Consist of two separate doors with a distance of not less than 300 millimetres between them; or Garage roofs (associated with two storey dwellings) which incorporate parapet walls and a roof not visible from adjacent public streets may be approved subject to design merit – Consist of a double tilt-up or panel-lift door with a maximum width of 5 metres Hipped roof with eaves Other roof styles are subject to merit 12 REQUIREMENTS: When considering domestic outbuildings such as garden sheds, workshops, free standing garages, aviaries and other similar buildings you need to ensure they; Don’t overshadow or block light from the windows of an adjoining dwelling Have no impact to the visual amenity of the streetscape Have no wall located closer than 0.6 metres to a non-street frontage property boundary (primary and secondary) if located on an allotment 500 sqm or less in area Have no wall located closer than 1 metre to a non-street frontage property boundary (primary and secondary if located on an allotment greater than 500 sqm in area Not impinge on the required minimum area of private outdoor open space for the dwelling; and Be finished in materials and colours to match with fencing materials or materials or colours of the associated dwelling or be finished in Bluestone, Grey Ridge or Hedge Colorbond® or equivalent. Domestic outbuildings must also comply with the following maximum heights and dimensions; Where more than one outbuilding is proposed, the total area of all outbuildings should not exceed the area specified in the previous table Where outbuildings are accessed from secondary frontages or visible from the street, the elevation of the outbuilding in public view must have a hip roof REQUIREMENTS: Clotheslines, bin receptacles and service metres should be sited unobtrusively and away from public view Letterboxes should be integrated with the fence, gate or retaining wall located along the front property boundary All letterboxes, including stand alone letterboxes, must be located within the property boundary and not on the verge 5.9 Air Conditioners As air conditioners can cause discomfort to neighbours it’s important that their location is chosen with care. REQUIREMENTS: Evaporative air conditioners should be low profile, located below the ridgeline and be of neutral colour or painted to match the roof Have no wall located closer than 6 metres to a primary or secondary street frontage property boundary They should be located so as not to be visible from the street Where the side or rear property boundary is adjacent to open space it must be demonstrated how the outbuilding will be treated as not to detrimentally impact of the amenity of open space (e.g. setback, materials, design, landscaping, levels, etc) otherwise the street frontage setback of 6 metres will apply Size of allotment 5.8 C LOTHESLINES and LETTERBOXES Dropper boxes’ (the interface material between the cooling unit and roof of the dwelling) should be painted to match the roof colour of the dwelling Winter covers for evaporative air conditioners should be coloured to match the roof Maximum dimensions of Outbuilding (m) Maximum wall height (m) Maximum ridge height (m) Length Width Total area (m2) 950 sqm + 10 6 60 2.4 3.2 500 – 950 sqm 7 6 42 2.4 3.2 Less than 500 sqm 5 3 15 2.4 3.2 13 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES 5.7 DOMESTIC OUTBUILDINGS 5.10 Signage REQUIREMENTS: No signage should be erected on any part of an allotment other than for the temporary purposes of selling or leasing the subject property 5.11 NBN REQUIREMENTS: Bluestone is a NBN (Fibre to the Home) estate, which means that every home requires specific wiring guidelines. Please consult www.nbnco.com.au and view the ‘My Builder’ page to access these guidelines in order to understand the minimum wiring requirements to make sure you can utilise your telecommunications services. 14 5.12 ROOF ATTACHMENTS (INCLUDING ANTENNAE AND SATELLITE DISHES) REQUIREMENTS: Attachments located on the roof of dwellings above the eaves line should generally be located so as to be unobtrusive when viewed from any public area Antennae are not permitted unless located within the roofspace Satellite dish/antennae protruding from the roof are not permitted 6. fencing Fencing and retaining walls are an integral part of your design as they provide privacy and enclosure, delineate between public and private spaces, and control level differences. The appearance of fencing and retaining walls can detract from the appearance of your property and the neighbourhood if designed inappropriately 6.1 SIDE AND REAR BOUNDARY FENCING REQUIREMENTS: Side fences along common property boundaries must be located 1 metre behind any building line of the home that faces the street Complying side fence and return – ends 1 metre behind front building line Any fencing forward of this point must comply with the Front Fencing requirements (Section 6.2) Side, return and rear boundary fences behind the building alignment are required to be 1.8 metres in height and constructed from Grey Ridge® coloured Colorbond® or equivalent Non-complying fence – projects past building line obstructing view of neighbouring house 15 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES For corner allotments, a maximum of 50% of the length of the secondary frontage can be constructed to 1.8 metres in height. If the remainder of the secondary frontage is fenced, it must have a maximum height of 1.2 metres and conform to Section 6.2 6.2 FRONT BOUNDARY FENCING REQUIREMENTS: For allotments having a primary frontage to a public road the following conditions apply; Fencing must be of open style in nature to enable views into front gardens The maximum fence height permitted is 1.2 metres and the minimum height permitted is 0.9 metres (excepting hedges where the minimum height is 0.6 metres) Masonry piers may extend above the fence to a maximum height of 1.5 metres Materials should conform to the following table and sketches Materials Picket (timber, steel, aluminium) – minimum 50 millimetres separation between uprights) Piered brick or masonry piers with steel, timber or aluminium uprights – minimum 50 millimetres separation Please note: Brush fences are not permitted for any fencing. 16 6.3 East Parkway Allotments 6.4 F encing Adjacent to Reserves REQUIREMENTS: REQUIREMENTS: For allotments that abut East Parkway, the ‘rear’ privacy fencing along the minor street property boundaries should; If your house has a boundary adjacent to a public reserve, special fencing is required that creates a reasonable level of privacy whilst retaining some outlook to the reserve. Reserve fencing is indicated on the Building Envelope Plan. Suitable fencing should be semi-permeable and may be landscaped with shrubs. Examples of suitable fencing are horizontal slatted timber or metal fencing or black metal post and railing (level plug) type fencing, to a maximum height of 1.8 metres above ground level. If you are uncertain whether a particular fence complies, contact the Encumbrance Manager Be set back a minimum of 1 metre from the ‘rear’ property boundary and this setback area should be landscaped with appropriate species Extend for a maximum of 50% along the property boundary Be consistent with the fencing described in Section 6.4 below Lockable gates that match the design and appearance of the fence will be allowed along the reserve frontage Please note: Gates and fences built by the Developer cannot be removed, relocated or replaced without prior written consent from the Encumbrance Manager. 6.5 LANDSCAPING FRONT GARDENS Within three months of moving into your home, you need to have landscaped your front garden. Landscaping of front gardens should; Screen or soften the appearance of storage, service and parking areas Generally be in scale with the buildings on the site Horizontal slatted timber fence Allow surveillance of entry points to dwellings Provide protection from sun and wind, while ensuring reasonable solar access to dwellings and private open space Minimise impermeable paved surfaces Use plant species suited to the site which minimise the need for maintenance Black metal post and rail fence Avoid interference with utility services and not unreasonably affect adjacent properties through overshadowing or intrusive root systems Examples of good landscape outcomes Landscaping of private gardens should involve the selection of; Species that are indigenous or suited to the geographic area Horizontal slatted metal fence Water efficient plants that will require minimal irrigation once established Plants that provide shade for dwellings and outdoor private open space during summer and allow solar access during winter (e.g. deciduous trees or vines) A suggested species list is available from The District Council of Mount Barker. 17 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Suitable species taking into account the eventual size, spread and root system of plants when mature 7. living at bluestone 7.1 recreational/ commercial vehicles REQUIREMENTS: Recreational vehicles (e.g. caravans, boats, camper trailers) and commercial vehicles must not be parked on properties forward of any part of the dwelling, including on the street or the footpath, and should be screened from the street 7.2 MAINTENANCE IT IS YOUR RESPONSIBILITY TO ESTABLISH AND MAINTAIN THE VERGE. 18 8. terrace home guidElines Terrace housing within Bluestone refers to allotments which allow the construction of walls along both side boundaries. There are a number of different terrace options available, with varying width and garage locations. Given the relatively narrow frontage of terrace homes these guidelines have been prepared to encourage a variety of styles which are in harmony with each other and the streetscape. Avenue Terrace Terrace Section 1 to 7 of these guidelines includes general requirements that apply to all terrace designs. Section 8 of the guidelines refers to specific requirements for each type of terrace. The diagram below will assist you in identifying each type of terrace option. Park Terrace City Terrace 19 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES FOR TERRACE HOUSING, THE AFOREMENTIONED GUIDELINES APPLY EXCEPT WHERE SPECIFIC ADDITIONAL OR TERRACE-SPECIFIC GUIDELINES APPLY. 8.1 General Requirements Each home is to incorporate a minimum of three materials on the street elevation(s) of varied texture and a minimum of three colours with the most neutral colour predominating. Building work is to be commenced within 24 months of settlement of the land. Each home is to be designed to address all street frontages. Side walls must be finished as per the front elevation unless covered by adjoining properties. Terrace homes may have a rear setback of 3.0 metres for upper and lower levels provided solar access to adjoining properties is maintained. These design guidelines are to be read in conjunction with the Bluestone guidelines Version 4 (December 2014). 20 CHARACTER AND PROPORTION OPEN SPACE REQUIREMENTS Modern contemporary forms with clean lines, a diversity of materials and colours, picking up on the timeless elements of Adelaide’s best housing. For allotments greater than 250 square metres, 20% of the allotment is required. Each dwelling is to be designed as a separate visual entity from its neighbours. No two adjacent terrace homes are to be constructed with the same street frontage. Houses are required to provide a modulated street frontage with an articulated façade and use of elements such as verandahs, balconies, window shading and porches to provide visual interest to the street. Exposed blank walls are not permitted. Elevations should be detailed with window openings and recessed sections. Given the relatively smaller frontage of each terrace dwelling it is required that considerable attention to detailing is given to the individual characteristics of each dwelling. For allotments less than or equal to 250 square metres, 40 square metres is required. Private open space areas of 25 square metres will be considered for allotments less than or equal to 250 square metres where the dwelling has no more than two bedrooms and a floor area less than 110 square metres. Rear balconies and roof patios will only be considered as private open space if they have a minimum area of 8 square metres with a minimum single dimension of 2.0 metres. Ground level private open space must have a minimum dimension of 2.5 metres. Use of front balconies as contributing to private open space is subject to District Council of Mt Barker approval. 21 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Detailing is to provide visual richness and variety, interest and identity and assist in reducing the visual bulk of building mass. LANDSCAPE DESIGN An indicative landscaping plan must be submitted with plans for encumbrance approval. Terrace lots with garage access from the street must follow one of the landscaping options shown to the right. 22 HEIGHT WINDOWS The overall height of the dwelling must not be higher than 9 metres. To be contemporary in design, form and placement. Building height is defined as the finished site level to the highest point of the roof ridge or pitching point and must either match those on the adjoining properties or vary by a maximum of 300mm. Windows must be of a ‘commercial’, ‘semi-commercial’, ‘timber’, ‘awning’ or ‘casement’ grade only and the same standard on all elevations. Three-storey dwellings will be considered on merit. ROOF DESIGN All roofs, except flat roofs are to be corrugated metal deck design or flat tiled shingle design. The minimum pitch of main roofs is at least 7.5 degrees for skillion and at least 25 degrees for hipped roofs. Windows and openings should address rear lanes. The use of reflective or obscure glass is not permitted on front elevations. Rooms requiring privacy should not be situated in such locations. CEILING HEIGHTS Minimum floor to ceiling height is required to be 2.7 metres for both lower and upper floors. Roof lines must be clean and visually uninterrupted by equipment such as air conditioning units. Roof gutters and rain water heads should be appropriate in scale and simple in design 23 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES A range of roof profiles which contribute to the contemporary feel of Bluestone may also be considered. PRIVACY CAR PARKING Outlook to streets and parks front internal and external living spaces should be maximised without compromising visual privacy. In accordance with the District Council of Mt Barker requirements: Privacy screening of 1.7 metres in height is to be provided to upper level windows or balconies that overlook other dwellings. No excessive overlooking or overshadowing is to occur to neighbouring windows or private open space. FRONT ENTRY POINTS Front entrances are to be visually obvious and easily accessible from the street frontage. Front doors are to be contemporary in design, form and placement. Front doors must have a sidelight and a top fan light ( a small vertical and horizontal window running alongside and on top of the entry door), or the entry door is to be a minimum of 2.4 metres high and 1.2 metres wide with glass inserts. 24 Dwellings with three bedrooms or less should be provided with a minimum of two on-site car parking spaces, one of which is covered. Dwellings with four or more bedrooms should be provided with a minimum of three on-site car parking spaces (the additional space may be tandem). In laneways the design of garage and carports must incorporate an articulated roof form that includes at least two elements, such as gables, hips or saw-tooth forms. FRONT FENCE A front fence is required to all dwellings. Colorbond® or solid metal panel fencing is not permitted. The front fence is to be constructed in the form of low walls, with timber/metal slats, hedges or the like used as infill between masonry pillars. The minimum and maximum heights for front fences are 1.0 metres and 1.2 metres respectively. Materials, colours and detailing are to be consistent and compatible with those of the main building. The front fence is to extend the entire frontage except for the driveways and pedestrian gateways. 25 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Letterboxes must be incorporated into the front fence design, or when required in the rear lane, be integrated into the portico. ENERGY EFFICIENCY WATER CONSERVATION LANEWAY FENCING In accordance with State Government requirements, all dwellings must achieve a 6-Star Energy Rating. This rating is important in order to reduce the energy consumption, greenhouse gas emissions, and ongoing costs of your home. All dwellings are to be fitted with WELS four star water-efficient taps and dual flush toilets as well as three star rated shower roses. Is to comply with the Bluestone Design Guidelines 02 (page 48) but as a secondary option to the portico requirement, terrace dwellings can have a 1.8 metre timber slat fence with a landscaping strip in front (irrigation points to be noted on plans). An external clothes line must be provided and shown on the plans. A minimum of one window must be provided to all main living areas. Gas water heating (or solar hot water system with gas backup) and a gas cook top are to be installed If a solar hot water system is to be used; – It should be a split system with the tank located within the roof space or on the ground – The solar collector panels should be located so that they are not highly visible from any public street or thoroughfare. Where visible from public areas, solar panels will be assessed on their merits with regard to scale, form and colour: and – In addition, solar collector panels should be supported on the roof and not on a separate frame The installation of energy-efficient light fixtures and lamps to every room and lighted outdoor area. As a minimum standard light bulbs must achieve 30 lumens/watt. 26 DIVIDING FENCES The dividing fence is required to be a 1.8 metre pre-painted metal friendly-neighbour type fence in Colorbond® ‘Grey Ridge’ in colour or similar. The dividing fence forward of the building line is required to be square metal black tubular fencing and 1.2 metres in height. Reserve fronted lots will be required to incorporate a letterbox into the portico area. Freestanding letter boxes will not be approved. WASTE MANAGEMENT Provision made for internal separate and conveniently accessible waste and recycling facilities. Identify placement of external storage of bins for general, recycling and green waste. These areas must be accessible, have convenient egress to the appropriate kerbside collection, but be discreetly located and not readily visible from the street. SERVICES AND ANCILLARY STRUCTURES Roof-mounted structures such as solar hot water systems, air conditioning systems, rooftop evaporative coolers, antennae, satellite dishes and the like shall be mounted such that they are not visible from the street or parks and shall be mounted sufficiently low to avoid breaking the line of the roof ridge. Service meters are to be accessible for service authority reading. Confirmation of connection of dwelling to Fibre Optic cable and location of outlet points through the home are required to be noted on the plans. Clothes drying areas must not be visible from streets, laneways or parks. A separate gas meter box may be located in the front garden directly behind a fencing pillar and in accordance with the requirements of the relevant authorities. The meterbox(s) for electricity and fibre must then be located in a discreet location on the dwelling. 27 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Solar hot water tanks may be located on the roof of terrace homes if it can be demonstrated that they will not be visible from the streets or parks. 8.2 Specific Requirements In addition to the standard terrace design guidelines the following additional requirements apply to each terrace type. Avenue Terrace An Avenue Terrace refers to a lot with a separate garage accessible from the rear lane. BUILDING SETBACKS Setbacks will be determined by the Building Envelope Plan (BEP) provided for each lot, there is to be no variation from the front and garage/carport setbacks as specified. The front setback requirements as indicated on the BEP are both a minimum and a maximum, meaning a solid full height wall is required up to, and not past the setback line. Balconies and other protrusions forward of the setback must be open in design and not located on the side boundaries. The main roof is required up to, and not past the setback line. PORCHES A portico or porch may be provided to the main street frontage. The porch may project beyond the main face of the dwelling to provide interest and articulation. Porch areas may be recessed behind the main setback line, provided a suitable level of articulation is provided to the home. A porch forward of the setback line must be open in design. Enclosed side walls will not be permitted. 28 Balconies forward of the main setback line are required to present as a secondary structure to the main dwelling so as not to confuse the main setback line of the streetscape. This is to be achieved by: – The use of open-style balconies that do not result in a bulky, dominating structure. Solid balustrade walling is not permitted. – If a roof is provided to the balcony it is required to be a separate or minor element of the main roof and must complement the dwelling. – Suitably proportioned balcony piers which complement the main face of the dwelling. Bulky, dominant piers which detract from the main dwelling will not be supported. – Ensuring a minimum setback of 500mm from both side boundaries. – Rear balconies must be designed to ensure overlooking into the private open space and windows of adjoining properties is not possible. The front balcony may protrude into the front setback by 1 metre, but a larger balcony can be provided within the upper floor level area. If this option is adopted the upper level wall will be required to continue to the front of the house for 500mm from each side boundary. Refer to diagram below: Cantilevering the balcony is possible. Innovation and variety in balcony designs is encouraged. Shadecloth or profiled clear acrylic roof sheeting is not permitted to front elevations. House designs without a balcony will be carefully assessed on merit. It is crucial that these designs have an interesting and articulated frontage. Main roof to extend to setback line Full-height solid boundary walls Min 0.5m setback Min 0.5m setback 29 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES BALCONIES Terrace BALCONIES AND PORCHES A Terrace refers to a lot with garage access from the street front. Balconies are not permitted forward of the main setback line. BUILDING SETBACKS Setbacks will be determined by the BEP provided for each lot, there is to be no variation from the front and garage/carport setbacks as specified. The front setback requirements as indicated on the BEP are both a minimum and a maximum, meaning a solid full height wall is required up to, and not past the setback requirement. The main roof is required to be located over the balcony and constructed up to the main setback line. Rear balconies must be designed to ensuring overlooking into the private open space and windows of adjoining properties is not possible. Innovation and variety in balcony designs is encouraged. A porch or portico may be provided forward of the main setback line provide it is of an open design. The diagram below illustrates two options for balconies and porches. Variations to these options will be considered on merit. 1.0m high open style balustrade 2.7m high wing wall 2.0 x 5.5m balcony Garage on ground floor level (shown dashed) 5.5m Porch 3.5m 2.0m 1.0m high open style balustrade 2.7m high wing wall 2.7m high wing wall 3.0 x 1.0m balcony Building footprint Garage on ground floor level (shown dashed) 3.0m 5.5m Building footprint Porch 1.0m high open style balustrade 2.7m high wing wall 3.0 x 5.5m balcony Garage on ground floor level (shown dashed) 5.5m Porch (below balcony) 30 2.5m 1.0m 2.0m 2.7m high wing wall Building footprint City Terraces A City Terrace refers to a corner lot with two dwellings addressing all street frontages. City Terrace sites must be designed to accommodate two two-storey community-titled dwellings. Each home must be designed to address all street frontages through the use of three materials of varied texture, appropriate window treatments, wrap around balconies and articulation. Car parking and private open space requirements are to be in accordance with the District Council of Mt Barker requirements. Balconies forward of the main setback are required to present as a secondary structure to the main dwelling so as not to confuse the main setback line of the streetscape. Setbacks will be determined by the BEP provided for each lot, there is to be no variation from the setbacks as specified. 31 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Each city terrace house must be designed as a separate dwelling to minimise the appearance as a single dwelling or duplex. Design variations between the two dwellings are required to extend beyond colours and materials. Variations should include but are not limited to the following: bulk and scale; detail and styling; porch design; balcony and balustrades; window type and proportion; roof colour, material, pitch and design; front door size and style; front fencing differentiation and plant selection. Park Terraces A Park Terrace refers to a lot with two frontages of equal quality and detail to a street/reserve and a laneway. Park Terrace sites must be designed to have a street/reserve and laneway frontage of equal quality. Both frontages are required to include three materials of varied texture and three colours. Development above the garage which fronts onto the laneway is required and must be built to the boundary. Balconies forward of the main setback line are required to present as a secondary structure to the main dwelling so as not to confuse the main setback line of the streetscape. This is to be achieved by: –T he use of open-style balconies that do not result in a bulky, dominating structure. Solid balustrade walling is not permitted. – I f a roof is provided to the balcony it is required to be a separate or minor element of the main roof and must complement the dwelling. –S uitably proportioned balcony piers which complement the main face of the dwelling. Bulky, dominant piers which detract from the main dwelling will not be supported. –E nsuring a minimum setback of 650mm from both side boundaries. –C antilevering the balcony is possible. – I nnovation and variety in balcony designs is encouraged. –S hadecloth or profiled clear acrylic roof sheeting is not permitted to front elevations. A minimum of 40 square metres for private open space is required. A minimum amount of the required private open space is to be provided within an internal courtyard area in accordance with the BEP. Entrances are to be visually obvious and easily accessible from the lane frontage. A covered entrance area with minimum dimension of 1.5 metres x 1.5 metres must be provided to the lane frontage to provide access and visual articulation. The entrance must be more visually dominant (ie. different material and height) than the garage component. Front doors on both frontages are to be 2.4 metres in height with glass inserts and contemporary in design, form and placement. 32 Corner Terraces A Corner Terrace lot is a lot located on a corner with equal quality to both street frontages. Corner dwellings are to be designed to have equal quality to both streets through the use of external materials and detailing common to each elevation, wrap-around verandahs and balconies, front fencing and feature window materials. Large singular hip, gable or skillion roofs without articulation will not be approved. Roofs are to be designed to address both the primary street frontage and the secondary street frontage. Setbacks on secondary street frontages are to be not less than 1.5 metres for single-storey components and 2.0 metres for two-storey components from the closest part of the building to the allotment boundary. Articulation is required to each street frontage of the home and on the secondary frontage of a corner block. Articulation can be created by entries, verandahs, porches, blade walls and the physical stepping of the walls. 33 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Consideration to the floor plan should be given to ensure that larger, feature windows are possible along the secondary street elevation. i.e avoid locating ensuites, laundries, and storage areas. Residential Design Guidelines – Appendix external building colours 34 ENCUMBRANCE APPROVAL APPLICATION FORM Stage 3, The outlook In order to avoid delays in the Encumbrance Approval process it is important to provide all the plan design details and specifications detailed below in order to assess your application. It is critical that your builder completes the Residential Design Guidelines Checklist to submit with this application. Lot Number:........................................................................................................................................................................................................ Address:�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� Owners Contact Details Builder / Architect / Designer Contact Details Name: Name: Address: Address: Phone: (work) Phone: (work) Phone: (home) Phone: (home) Mobile: Mobile: Fax: Fax: Email: Email: Supplied (tick as appropriate) Items SITE PLAN (2 copies drawn to scale of not less than 1:200) Allotment boundaries, dimensions, easements, and road name(s) Location and dimensions of all existing and proposed building(s), structures, driveways and existing trees Site contour levels, proposed bench levels and finished floor levels, location of retaining walls, (indicating height and materials used) Written consent of adjoining neighbour for retaining wall(s) on common alignment Distance between proposed building(s) and any other buildings on the site, including distance from boundaries Minimum 3,000 rainwater storage and fire fighting capacity By Builder Minimum 3,000 rainwater storage and fire fighting capacity Note: Owner acknowledgement must be signed By Owner North point Longitudinal section of driveway or design levels 35 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES Method and direction of disposal of roof and storm water Architectural drawings (2 copies drawn to scale of not less than 1:100) Floor Plan of proposed building(s) showing dimensions, intended use of rooms, existing floor areas (if applicable), window and access arrangements Elevations of all sides of the proposed dwelling Schedule of external materials and colours Landscaping plan and fencing details Plan showing species, number and location of plants for front gardens Side and rear fencing location, materials used and colour NOTE: Side fencing must terminate 1.0 metres behind the adjacent front building line Energy efficiency information Insulation specifications for walls and ceilings Minimum requirement of GAS water heating and cook top GAS boosted Solar Hot Water Service (applicable where Solar supplied) Other NBN pre-wiring By Builder NBN pre-wiring Note: OWNER and BUILDER ACKNOWLEDGEMENT MUST BE SIGNED By Builder Encumbrance Manager application fee: $385.00 (inc GST) (As of July 1. 2011) Other notes: ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� SIGNED............................................................................................ DATE�������������������������������������������������������������������������������������������������������� PRINT NAME....................................................................................................................................................................................................... Owner/Builder/Architect/Designer (strike out whichever is not applicable) 36 Owner acknowledgement : NBN I/we ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� the owners of Lot....................Street................................................................................................................................................................ acknowledge the responsibility/intent to install NBN to the above mentioned premises in accordance with the minimum requirements as defined within www.nbnco.com.au SIGNED............................................................................................ DATE�������������������������������������������������������������������������������������������������������� PRINT NAME....................................................................................................................................................................................................... BUILDER ACKNOWLEDGEMENT: NBN I/we ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� the contracted builder for premises at Lot....................Street.................................................................................................................... acknowledge access will be afforded to an accredited contractor for the purpose of pre-wiring NBN SIGNED............................................................................................ DATE�������������������������������������������������������������������������������������������������������� PRINT NAME....................................................................................................................................................................................................... OWNER ACKNOWLEDGEMENT: Rainwater tank(s) I/we ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� the owners of Lot....................Street................................................................................................................................................................ acknowledge the responsibility/intent to install a minimum 3,000 litre capacity Rainwater tank(s) to the above mentioned premises prior to occupation of the dwelling SIGNED............................................................................................ DATE�������������������������������������������������������������������������������������������������������� 37 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES PRINT NAME....................................................................................................................................................................................................... EXPLANATORY NOTES As described in Clause 5.11 of the Bluestone Residential Design Guidelines, Bluestone at Mount Barker is a NBN (Fibre to the Home) estate, which means that every dwelling requires specific wiring guidelines, compliance is mandatory. (Refer www.nbnco.com.au). Wiring must be installed during construction can not be retro fitted, therefore it is essential to determine who bears responsibility. All applicants at Bluestone are required to complete a general Application Form, within which are certain acknowledgements to be made regarding NBN wiring. If the task is to be undertaken by the BUILDER – Complete pages 1 and 2 of the application form and tick – NBN pre-wiring.................................................................BY BUILDER � OR If the task is to be undertaken by the OWNER – Complete pages 1 and 2 of the application form and tick – NBN pre-wiring.................................................................BY OWNER � then Page 3 of the application must be completed OWNER ACKNOWLEDGEMENT must be signed by the owner. and BUILDER ACKNOWLEDGEMENT must be signed by the owner. ENCUMBRANCE APPROVAL CAN NOT BE ISSUED WITHOUT COMPLETED FORMS 38 Residential Design Guidelines Summary Checklist Stage 3, The outlook In order to avoid delays in the Encumbrance Approval process it is important to provide all the plan design details and specifications detailed below in order to assess your application. It is critical that your builder completes the Residential Design Guidelines Checklist to submit with this application, this checklist has also been supplied in the Encumbrance Approvals and Residential Design Guidelines section of the “Building Your New Home” kit. Name of Applicant:.......................................................................................................................................................................................... Address of Property:���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� RDG Requirement Compliant Non Compliant Not Applicable Comment Reason for Non Compliance TICK AS APPROPRIATE 2.2 Energy Efficiency – Gas Water heating/Cook top – Gas Boosted Solar HWS (if Solar HWS is used) 2.3 Water Conservation/ min 3000L RWT – Unexposed to public view 2.4 Environmental protection/ Existing trees 3.1 Building Envelope – Setback from Street – Setback from side boundaries – Setback from rear boundary – Upper Level setbacks – Site Coverage – % 3.2 Privacy issues addressed (Upper Level) 3.3 Garage/Carport setback (relative to main façade) – Max cut 1.50 metres – Max fill 1.50 metres 3.5 Retaining Walls – Single wall max 1.0 metres – Combined wall max 1.50 metres – Adjacent to Public Road/ Reserve – Material used – Written consent of neighbour 39 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES 3.4 Site works RDG Requirement Compliant Non Compliant Not Applicable TICK AS APPROPRIATE 4.1 Driveway Location 4.2 Driveway Width 4.2.1 East Parkway vehicle access 4.3 Crossover width and materials 5.1 Front Façade – Verandah or Porch/Portico – Additional Design Element (min of 1) 5.2 Corner facade detail addressed (second ary street frontage/ return detail/Min 8.0 metres) – Windows corresponding with Main Facade 5.3 walls /main facade (min 2 Elements Required) – Element 1 – Element 2 Walls/Secondary Frontage (min 2 Elements Required) – Element 1 – Element 2 5.4 East Parkway Allotments – Front appearance – Rear access appearance Park Frontage Allotments – Reserve appearance 5.5 Roof Materials and Form – Min 25˚ pitch – Min 450 millimetres wide eaves 5.6 Garages and Carports – 2 Sep Doors/350 millimetres pier – Double Tilt up/Panel Lift/5.0 metres – Garage max 50% of building frontage width 40 Comment Reason for Non Compliance RDG Requirement Compliant Non Compliant Not Applicable Comment Reason for Non Compliance TICK AS APPROPRIATE 5.7 Domestic Outbuildings 5.8 Clothes line/Letterbox 5.9 Air Conditioner 5.11 NBN Requirements (Application Form) 5.12 Roof Attachments 6.1 Fencing – Side and Rear – Secondary frontage 6.2 Front Boundary fencing 6.3 East Parkway Allotments / Rear Fencing 6.4 Fencing adjacent Reserves 6.5 Front garden landscape plan COMPLETED APPLICATION FORM NBN ACKNOWLEDGEMENT including owner/builder acknowledgements as required Application Fee 41 BLUESTONE MT BARKER RESIDENTIAL DESIGN GUIDELINES OTHER
© Copyright 2024