data sheets of selected equipment

Phone: +92 (0) 300 8220135
+92 (0) 305 5552343
Mail: info@espire.com.pk
bfz gGmbH - International Division
Training & Development Centers of the
Bavarian Employers´Associations
Internet: www.espire.com.pk
Specifications of Available Energy Monitoring Equipment
No.
Equipment
Model
1
3 Phase Power Analyzer
Fluke 1730, Fluke Corporation USA
2
Flue Gas Analyzer
Testo 320, Testo GmbH Germany
3
Flue Gas Analyzer
Testo 340, Testo GmbH Germany
4
Compressed Air, Gas Thermal Mass Flow Meter
OGF5400_PENTA, Omni Telemetry Co. Canada
5
Steam Flow Meter
OSF/FCU 5400, Omni Telemetry Co. Canada
6
Steam Flow Meter
Vortex Flow Meter TLV -EF-73, TLV Co. Japan
Fluke 1730
Three-Phase Electrical
Energy Logger
Technical Data
Energy logging is now within your reach—
discover where you’re wasting energy, optimize
your facility’s energy use and reduce your bill.
The new Fluke 1730 Three-Phase Electrical Energy logger
introduces a new simplicity to discovering sources of
electrical energy waste. Discover when and where
energy in your facility is being consumed; from the
service entrance to individual circuits. Profiling energy
usage across your facility helps you identify opportunities
for energy savings, and provides you with the data you
need to act on them. The new Energy Analyze software
package allows you to compare multiple data points over
time to build a complete picture of energy usage, which
is the first step to reduce the cost of your energy bill.
• Key measurements: voltage, current, power,
power factor and associated values enable
energy saving strategies to be implemented.
• Bright, color touch screen: perform convenient in-the-field analysis and data checks
with full graphical display.
• Comprehensive logging: all measured values
are automatically logged and can be reviewed
during logging and before downloading for onthe-go analysis. More than 20 separate logging
sessions can be stored on the instrument.
• Optimized user interface: quick, guided,
graphical setup ensures you’re capturing the
right data every time, and the intelligent verification function indicates correct connections
have been made, reducing user uncertainty.
• Complete ‘in-the-field’ setup through the
front panel: no need to return to the workshop
for download and setup or to take a computer
to the electrical panel.
• Wide range power: power instrument directly
from the measured circuit eliminating the
need to find a power outlet while allowing the
instrument to be secured safely inside electrical panels.
• Two USB ports: one for PC connection and
another for fast, simple download to standard
USB thumb drives, or other USB devices.
• Compact size: designed to fit in tight spaces
and panels.
• Highest safety rating in the industry: 600 V
CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
• Optimized measurement accessories: flat
voltage cable and thin flexible current probes
ensure easy installation even in tight spaces.
• Battery life: four-hour operating time (backup
time) per charge on lithium-ion battery.
• Security: safeguard against theft with a
Kensington lock.
• All new, Energy Analyze application software: download, analyze and automated
reporting for a complete picture of energy
saving potential.
Applications
Power and energy logging
When a piece of equipment is operated it instantaneously consumes a specific amount of power in
watts (W) or kilowatts (kW). This power is accuDiscover how much energy individual pieces of
mulated over the operating time and expressed as
equipment are consuming when they are operatenergy consumed in kilowatt hours (kWh). Energy
ing at minimum and maximum capacity. Check
is what your electric utility charges for; there will
capacity of circuits prior to adding additional
be a standard charge from the utility per kilowatt
loads (various standards exist for this process;
hour. Utilities may have other additional charges,
in the US the NEC 220-87 is the recommended
standard). Load studies can also identify situations such as peak demand, which is the maximum
power demand over a defined period of time,
where you may be exceeding the allowable load
often 15 or 30 minutes. There may also be power
on the circuit or when an agreed peak demand
factor charges, which are based on the effects of
applies from the utility. For convenience, some
load studies simply measure current which makes the inductive or capacitive loads in the facility.
installation of the measuring equipment quick and Optimizing peak demand and power factor often
results in lower monthly electricity bills. The
easy. It is often recommended that load surveys
1730 Three Phase Electrical Energy logger has
be performed for 30 days so that all typical load
the capability to measure and characterize these
conditions are encountered during the test.
effects enabling you to analyze the results and
save money.
Energy surveys
Users often ask where measurements should be
Simplified load studies
taken for an energy survey. The answer is mulFor situations where it’s either difficult or impractiple points within the facility. Start at the main
tical to make a voltage connection the simple load
service feeders; compare the power and energy
study feature allows users to perform a simplified
measured here with the readings from the utilload study by measuring current only. The user
ity meter to ensure you’re receiving the correct
can enter the nominal expected voltage to create
charges. Then move downstream to the larger
loads; these should be easy to identify by the cur- a simulated power study. For accurate power
rent rating of the electrical panels downstream of and energy studies it is required to monitor both
voltage and current but this simplified method is
the service entrances. Measuring at many points
useful in certain circumstances.
will allow a full picture of energy usage across
the facility to be developed. The next question users typically have is how long an energy
survey should last. This of course depends on the
facility, but it is recommended that you measure
for a period that matches a typical facility activity period. If the facility operates over a five day
work week with down time on the weekend, a
seven day survey will most likely capture typical
conditions. If the facility operates at a constant
level for 24 hours a day, 365 days a year, a single
day could be reasonably representative as long as
you avoid a period where there may be planned
maintenance.
To capture a full picture of the facilities energy
usage it is not necessarily required to have
measurements made simultaneously at every
consumption point in the facility. To get a comprehensive picture, spot measurements can be made
and then compared on a sliding time timescale.
For example, you could compare the service
entrance results from a typical Tuesday between
6:00 am and 12:00 pm with those of a larger load
in the facility. Typically there will be some correlation between these profiles.
Load studies
2 Fluke Corporation
Fluke 1730 Three-Phase Electrical Energy Logger
Specifications
Accuracy
Parameter
Voltage
iFlex1500-12
Current:
Direct input
iFlex3000-24
iFlex6000-36
i40s-EL clamp
Frequency
Aux input
Voltage Min/Max
Current Min/Max
Cosϕ/DPF
Power factor
THD on voltage
THD on current
Range
Resolution
1000 V
150 A
1500 A
300 A
3000 A
600 A
6000 A
4A
40 A
42.5 Hz to 69 Hz
± 10 V dc
1000 V
defined by
accessory
0 <= Cosϕ <=1
0 <= PF <=1
1000 %
1000 %
0.1 V
0.1 A
1A
1A
10 A
1A
10 A
1 mA
10 mA
0.01 Hz
0.1 mV
0.1 V
defined by
accessory
0.01
0.01
0.1 %
0.1 %
Intrinsic Accuracy at Reference Conditions
(% of Reading + % of Full Scale)
± (0.2 % + 0.01 %)
± (1 % + 0.02 %)
± (1 % + 0.02 %)
± (1 % + 0.02 %)
± (1 % + 0.02 %)
± (1.5 % + 0.03 %)
± (1.5 % + 0.03 %)
± (0.7 % + 0.02 %)
± (0.7 % + 0.02 %)
± (0.1 %)
± (0.2 % + 0.02 %)
± (1 % + 0.1 %)
± (5 % + 0.2 %)
±
±
±
±
0.025
0.025
(2.5 % ± 0.05 %)
(2.5 % ± 0.05 %)
Intrinsic uncertainty ± (% of reading + % of range)1
Parameter
Influence
iFlex1500-12
iFlex3000-24
quantity
150A/1500A
300A/3000A
Active power P
PF ≥ 0.99
1.2 % +
1.2 % +
0.005 %
0.0075 %
0.5 <PF <0.99
1.2 % + 7 x
1.2 % + 7 x
(1-PF)
(1-PF)
+0.005 %
+ 0.0075 %
Apparent power S, S fund.
0 ≤ PF ≤ 1
1.2 % +
1.2 % +
0.005 %
0.0075 %
Reactive power N, Q fund.
0 ≤ PF ≤ 1
2.5 % of measured apparent power
Additional uncertainty in %
U >250 V
0.015 %
0.0225 %
of range1
1
iFlex6000-36
600/6000A
1.7 % +
0.0075 %
1.7 % + 7 x
(1-PF)
+ 0.0075 %
1.7 % +
0.0075 %
i40s-EL
4A/40A
1.2 % +
0.005 %
1.2 % + 10 x
(1-PF)
+ 0.005 %
1.2 % +
0.005%
0.0225 %
0.015 %
Range = 1000 V x Irange
Reference conditions:
Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V
Input current: I > 10 % of Irange
Primary conductor of clamps or Rogowski coil in center position
Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
3 Fluke Corporation
Fluke 1730 Three-Phase Electrical Energy Logger
Electrical specifications
Power supply
Voltage range
Power consumption
Efficiency
Maximum no-load consumption
Mains power frequency
Battery
On-battery runtime
Charging time
Data acquisition
Resolution
Sampling frequency
Input signal frequency
Circuit types
THD
Averaging period
Demand interval
Data storage
Memory size
Logging period
100 V to 500 V using safety plug input when powering from the measurement
circuit
100 V to 240 V using standard power cord (IEC 60320 C7)
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
≥ 68.2 % (in accordance with energy efficiency regulations)
< 0.3 W only when powered using IEC 60320 input
50/60 Hz ± 15 %
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
Four hours in standard operating mode, up to 5.5 hours in power saving mode
< 6 hours
16-bit synchronous sampling
5120 Hz
50/60 Hz (42.5 to 69 Hz)
1-ϕ, 1-ϕ IT, Split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ
Aron/Blondel (2-element delta), 3-ϕ delta open leg, Currents only (load studies)
THD for voltage and current is calculated using 25 harmonics
User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
User selectable: 5 min, 10 min, 15 min, 20 min, 30 min
Internal flash memory (not user replaceable)
Typical 20 logging sessions of 10 weeks with 10-minute intervals1
Averaging period
1 second
5 seconds
10 seconds
30 seconds
1 minute
5 minutes
10 minutes
15 minutes
30 minutes
Interfaces
USB-A
USB-mini
Extension port
Voltage inputs
Number of inputs
Maximum input voltage
Input impedance
Bandwidth (-3 dB)
Scaling
Measurement category
Current inputs
Number of inputs
Input voltage
Rogowski coil input
Range
Bandwidth (-3 dB)
Scaling
Recommended
for 20 sessions
3 hours
15 hours
28 hours
3.5 days
7 days
5 weeks
10 weeks
3.5 months
7 months
File transfer via USB flash drive, firmware updates
Max. current: 120 mA
Data download device to PC
Accessories
4 (3 phases and neutral)
1000 Vrms, CF 1.7
10 MΩ
2.5 kHz
1:1, 10:1, 100:1, 1000:1 and variable
1000 V CAT III/600 V CAT IV
3, mode selected automatically for attached sensor
Clamp input: 500 mVrms/50 mVrms; CF 2.8
150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal
probe range
1 A to 150 A/10 A to 1500 A with thin iFlex flexible current probe, 12 inches
3 A to 300 A/30 A to 3000 A with thin Flex flexible current probe, 24 inches
6 A to 600 A/60 A to 6000 A with thin iFlex flexible current probe, 36 inches
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
1.5 kHz
1:1 and variable
1
The number of possible logging sessions and logging period depends on user requirements.
4 Fluke Corporation
Logging Period
for 1 session
2.5 days
12 days
24 days
10 weeks
20 weeks
2 years
> 2 years
> 2 years
> 2 years1
Fluke 1730 Three-Phase Electrical Energy Logger
Auxiliary inputs
Number of inputs
Input range
Scale factor (available 2014)
Displayed units (available 2014)
Environmental specifications
Operating temperature
Storage temperature
Operating humidity
Operating altitude
Storage altitude
Enclosure
Vibration
Safety
EMI, RFI, EMC
Electromagnetic compatibility
Radio frequency emissions
Temperature coefficient
General specifications
Color LCD display
Warranty
Dimensions
Weight
External protection
5 Fluke Corporation
2
0 to ± 10 V dc, 1 reading/s
Format: kx + d user configurable
User configurable (7 characters, for example, °C, psi, or m/s)
-10 °C to +50 °C (14 °F to 122 °F)
-20 °C to +60 °C (−4 °F to 140 °F)
10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
12,000 m
IP50 in accordance with EN60529
MIL 28800E, Type 3, Class III, Style B
IEC 61010-1: Overvoltage CAT IV, Measurement 1000 V CAT III/600 V CAT IV,
Pollution Degree 2
EN 61326-1: Industrial
Applies to use in Korea only. Class A Equipment (Industrial Broadcasting and
Communication Equipment)
IEC CISPR 11: Group 1, Class A
0.1 x accuracy specification/°C
4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
1730 and power supply: Two-years (battery not included)
Accessories: One-year
Calibration cycle: Two-years
1730: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
1730 with power supply attached: 19.8 cm x 16.7 cm x 9 cm
(7.8 in x 6.6 in x 3.5 in)
1730: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
Holster, Kensington lock slot
Fluke 1730 Three-Phase Electrical Energy Logger
1500-12 iFlex Flexible Current Probe specifications
Measuring range
Nondestructive current
Intrinsic error at reference condition*
Accuracy 1730 + iFlex
Temperature coefficient over operating temperature range
Working voltage
Probe cable length
Probe cable diameter
Minimum bending radius
Output cable length
Weight
Transducer cable material
Coupling material
Output cable
Operating temperature
Temperature, non-operating
Relative humidity, operating
IP rating
Warranty
1 to 150 A ac / 10 to 1500 A ac
100 kA (50/60 Hz)
± 0.7 % of reading
± (1 % of reading + 0.02 % of range)
0.05 % of reading/°C 0.09 % of reading/°F
1000 V CAT III, 600 V CAT IV
305 mm (12 in)
7.5 mm (0.3 in)
38 mm (1.5 in)
2 m (6.6 ft)
115 g
TPR
POM + ABS/PC
TPR/PVC
-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor
under test shall not exceed 80 °C (176°F)
-40 °C to +80 °C (-40 °F to 176 °F)
15 % to 85 % non-condensing
IEC 60529:IP50
One-year
*Reference condition:
• Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 %
• Primary conductor in center position
Ordering information
1730/BASIC Three-Phase Electrical Energy logger (excludes current probes).
1730/US Portable Energy Logger US version
1730/EU Portable Energy Logger EU version
1730/INTL Portable Energy Logger INTL version
Accessories
i1730-flex1500 iFlex flexible current probe 1500A 12 inch
i1730-flex3000 iFlex flexible current probe 3000A 24 inch
i1730-flex6000 iFlex flexible current probe 6000A 36 inch
i40s-EL i40s-EL Clamp-on Current Transformer
i1730-flex1500/3pk iFlex flexible current probe 1500A 12 inch, 3 pack
i1730-flex3000/3pk iFlex flexible current probe 3000A 24 inch, 3 pack
i1730-flex6000/3pk iFlex flexible current probe 6000A 36 inch, 3 pack
i40s-EL/3pk i40s-EL Clamp-on Current Transformer, 3 pack
1730-TL0.1M Test Lead Set; 1000 V CAT III, straight plug; 0.1 m; silicone; red/black
1730-TL2M Test Lead Set, 1000 V CAT III; straight plug; 2 m; PVC red/black
3PHVL-1730 Cable Assembly, Voltage Test Lead 3-Phase+N
C1730 1730 Soft Case
WC100 Color Localization Set
1730-Hanger Hanging strap
1730-Cable AUX input cable
Fluke. The Most Trusted Tools
in the World.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2013 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 8/2013 4314073B_EN
Pub ID: 12028-eng Rev. 01
Modification of this document is not permitted
without written permission from Fluke Corporation.
6 Fluke Corporation
Fluke 1730 Three-Phase Electrical Energy Logger
testo-340-P01
15.02.2013
10:09
Seite 1
We measure it.
Flue gas analyzer for
industry
testo 340 – Portable measuring
instrument for industrial emission
measurement
O2
Measuring range extension for unrestricted measurement at
CO
high gas concentrations
Flue gas analysis with up to 4 gas sensors – freely
CO l o w
configurable
Large selection of probes
NO
Bluetooth interface
Convenient measurement data management
NO l o w
TÜV-tested /EN norm
NO 2
SO 2
The handy, easy-to-operate emission measuring instrument
The unique measuring range extension allows unrestricted
testo 340 is the right tool for many different emission
measurements to be carried out even at high gas
measurements. The compact design and the reliable
concentrations. The testo 340 is equipped with an O2
technology make it the ideal measuring instrument for
sensor as standard. Three further gas sensors can be
commissioning, service and maintenance work and in test
configured individually, in order to be able to adapt the
measurements on industrial burners, stationary industrial
instrument optimally to the respective measurement task.
engines, gas turbines and thermal processes.
www.testo.com
testo-340-P02-03
15.02.2013
10:11
Seite 2
testo 340
We measure it.
Product properties
Automatic sensor protection at high gas concentrations
Thanks to the automatic measuring range extension, the measuring
range of your CO, COlow, NO, NOlow or SO2 sensor is extended 5-fold. The
sensor is placed under no greater strain at high gas concentrations than
at low concentrations. The automatic sensor protection protects the
sensor from overload without terminating the measurement.
Optionally, the measuring range of all sensors in the instrument can be
simultaneously extended by a factor of 2.
Measurement up to e.g.
max. 50,000 ppm (CO), or
max. 20,000 ppm (NO), or
max. 25,000 ppm (SO2), without overloading the sensor.
Space for 4 gas sensors
testo 340 is fitted with an O2 sensor as
standard. Three additional toxic gas sensors
such as CO, COlow, NO, NOlow, NO2 oder SO2
can be selected by the user. This guarantees
highest flexibility when adapting to changing
applications and measurement jobs.
Simply select, change and add the gas sensors
required at any time! For this purpose, select
from these seven pre-calibrated gas sensors:
1) NO2 sensor
The sensor can be changed or upgraded in an
additional gas parameter by the user directly
on-site without time-consuming test gas
adjustment.
2) SO2 sensor
3) COlow sensor
4) NOlow sensor
5) NO sensor
6) CO sensor
7) O2 sensor (standard)
Convenient measurement data
management with "easyEmission"
Data can be read out, easily processed, filed
and managed using the "easyEmission"
software:
Advantages of easyEmission
· Readings are shown in table or graph form
· User-defined measurement spacing (from one measurement / second to one measurement / hour)
· Online measurements via BLUETOOTH® wireless transmission or USB connection
· Customer and application-specific measurement protocols
· Data structure and measurement information can be transmitted from computer to analyzer
· All instrument configurations and settings can be easily carried out with easyEmission
· Direct transmission to Excel and pdf formats
· Easy implementation of individual formulae for your own calculations
· Calculation of fuel factors when using customer-specific fuels
testo-340-P02-03
15.02.2013
10:11
Seite 3
testo 340
We measure it.
Large selection of flue gas
sampling probes
Different probe shaft lengths,
diameters and temperature ranges
ensure high flexibility for all
applications. To change, the
probe shaft is simply attached to
the probe handle and engages.
Special flue gas probes for
industrial engines are designed
for positive pressure at the
measurement site, making
measurements possible even in
the toughest conditions. In
addition, modular industrial
probes are available for rugged
process conditions.
Wireless transmission*
* Country permits BLUETOOTH®
wireless transmission, see
Technical Data on page 8.
Ready to operate immediately
The highly robust fast-action
probe coupling for all gas paths
eliminates any confusion. The
indestructible gas sampling hose
cannot be bent, can be extended
up to 7.8 m and saves space. The
probe can remain positioned in
the flue gas during the zeroing
phase of the gas sensors. The
calibration phase of testo 340 is
finished after only 30 seconds.
Wireless readout, transmission and printing
of readings
Wireless connection via Bluetooth® 2.0 to Testo
BLUETOOTH® printers and direct communication
to notebook/PC over a distance of up to 10 m (free
field) are features of the new testo 340 option.
Readings and configurations are transmitted
wirelessly to your notebook/PC for storage and
analysis. Print data is transmitted wirelessly to the
printer by infrared interface (visual contact
required) or by new BLUETOOTH® wireless
transmission. This saves time since the analyzer is
ready for use again immediately following data
transmission.
Measurement gas pump
The automatically controlled measurement gas pump built into
testo 340 is the ideal solution for typical situations which arise
when measuring flue gas such as negative or positive pressure
(from -200 to +50 mbar). Pump flow is automatically kept
constant.
Integrated condensate trap
The Testo design eliminates the possibility of condensation
accumulating in the actual gas sensor. The testo 340 warns if the
condensation trap needs to be emptied.
Large selection of probes
18 standard fuels and 10 additional user-defined fuels can be adapted
specifically to each application.
testo-340-P06-07
15.02.2013
10:14
Seite 6
testo 340
Ordering data
Analyzer / Options
testo 340 flue gas analyzer, incl. rechargeable battery, calibration protocol and carrying strap, equipped with O2 sensor,
integrated flow/differential pressure measurement
Part no.
0632 3340
testo 340 must be equipped with a second gas sensor otherwise the analyzer cannot function.
Max. 3 additional sensors can be fitted.
Option CO sensor, 0 to 10000 ppm, resolution 1 ppm
Option COlow sensor, 0 to 500 ppm, resolution 0.1 ppm
Option NO sensor, 0 to 4000 ppm, resolution 0.1 ppm
Option NOlow sensor, 0 to 300 ppm, resolution 0.1 ppm
Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm
Option: SO2 measurement module, 0 to 5,000 ppm
Option: BLUETOOTH® module
Option: dilution of all sensors
Accessories
Part no.
Transport case for flue gas analyzer and probes
0516 3400
Mains unit international 100-240 V AC / 6.3 V DC for mains operation or battery charging in instrument, for mains
operation or battery charging in instrument
0554 1096
Software "easyEmission", incl. USB connection cable instrument-PC
0554 3334
Multiple license/"easyEmission" software
0554 3338
Testo fast printer IRDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries
0554 0549
BLUETOOTH printer set with wireless BLUETOOTH interface; incl. 1 roll thermal paper, rechargeable battery and mains unit
0554 0553
Spare thermal paper for printer, permanent ink
0554 0568
Spare rechargeable battery with charger
0554 1087
Exchangeable filter NO sensor (1 off), blocks cross-gas SO2
0554 4150
Replacement filter CO sensor (1 pcs.)
0554 4100
Calibration Certificates
Part no.
ISO calibration certificate/flue gas
0520 0003
ISO calibration certificate velocity, hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s
0520 0004
ISO calibration certificate velocity, hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s
0520 0034
Probes
Standard gas sampling probes: Modular flue gas probes, available in 2 lengths, incl. probe stop, NiCr-Ni
thermocouple, 2.2 m hose and particle filter
Part no.
Modular flue gas probe 335 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 500 °C
and NO2/SO2 special hose 2.2 m
0600 9766
Modular flue gas probe 700 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 500 °C
and NO2/SO2 special hose 2.2 m
0600 9767
Modular flue gas probe 335 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 1000 °C
and NO2/SO2 special hose 2.2 m
0600 8764
Modular flue gas probe, 700 mm immersion depth, incl. cone, thermocouple NiCr-Ni Tmax 1000 °C
and NO2/SO2 special hose 2.2 m
0600 8765
Modular flue gas probe with pre-filter Ø 14 mm 335 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI)
Tmax 1000°C and NO2/SO2 special hose 2.2 m
0600 8766
Modular flue gas probe with pre-filter Ø 14 mm 700 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI)
Tmax 1000°C and NO2/SO2 special hose 2.2 m
0600 8767
testo-340-P06-07
15.02.2013
10:14
Seite 7
testo 340
We measure it.
Probes
Probe accesories/standard gas sampling probes
Part no.
Hose extension; 2.8 m; extension cable for probe and analyzer
0554 1202
Probe shaft with pre-filter, length 335 mm, incl. cone, Ø 8 mm, Tmax 1000 °C
0554 8766
Probe shaft with pre-filter, length 700 mm, incl. cone, Ø 8 mm, Tmax 1000 °C
0554 8767
Spare sintered filter, 2 off
0554 3372
Spare dirt filter, modular probe; 10 off
0554 3385
Probe shaft, length probe shaft 700 mm, Tmax probe shaft 500 °C, Ø probe shaft 8 mm
0554 9767
Probe shaft with probe stop, length probe shaft 335 mm, Tmax probe shaft 1000 °C, Ø probe shaft 8 mm
0554 8764
Probe shaft length 700 mm, incl cone, Ø 8 m, Tmax. 1000 °C
0554 8765
Engine probes
Part no.
Flue gas probe for industrial engines, 335 mm immersion probe incl. cone, integrated condensate trap and heat
protection plate, Tmax 1000 °C, special hose for NO2/SO2 measurements, length 2.2 m
0600 7560
Flue gas probe for industrial engines with probe shaft prefilter, immersion depth 335 mm, incl. cone, integrated
condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2-/SO2 measurements, length 2.2 m
0600 7561
Thermocouple for exhaust gas temperature measurement, NiCr-Ni, length 400 mm, Tmax. +1000 °C with 2.4 m
connection cable and additional temperature protection
0600 8894
Spare particle filter (10 off) for condensate trap in gas sampling hose
0554 3371
Industrial probes
Part no.
Adapter, non-heated, IP54, gas input G1/4", gas exit M10x1 external thread
0600 7911
Extension pipe to +600 °C, stainless steel 1.4571, 1 m
0600 7802
Extension pipe to +1200 °C, Inconel 625, 1 m
0600 7804
Non-heated sampling pipe to +600 °C, stainless steel 1.4571, 1 m
0600 7801
Non-heated sampling pipe to +1200 °C, Inconel 625, 1 m
0600 7803
Non-heated sampling pipe to +1800 °C, Al-Oxide, 1 m
0600 7805
Pre-filter for dusty flue gases, ceramic, dust load max. 20 g/m³, filter pore size 20 μm, temperature max. 1000 °C
pre-filter can only be mounted on extension pipe 0600 7802 or 0600 7804.
0554 0710
Gas sampling hose for precise NO2-/SO2-measurements with built-in condensate trap, length 2.2 m
0554 3352
Thermocouple, NiCr-Ni, -200 to +1200 °C, Inconel 625, length 1.2 m
0430 0065
Thermocouple, NiCr-Ni, -200 to +1200 °C, Inconel 625, length 2.2 m
0430 0066
Mounting flange, stainless steel 1.4571 adjustable quick-action fitting suitable for all sampling/extension pipes
0554 0760
Temperature probes
Part no.
Mini ambient air probe; for separate ambient air temperature measurement; 0 to +80 °C
0600 3692
Combustion air temperature probe, immersion depth 60 mm
0600 9797
Pitot tubes
Part no.
Pitot tube, 350 mm long, stainless steel, measures flow velocity
0635 2145
Pitot tube, 1000 mm long, stainless steel, measures flow velocity
0635 2345
Connection hose; silicone; 5 m long; max. load 700 hPa (mbar)
0554 0440
Pitot tube, stainless steel, 750 mm long, measures flow velocity with temperature,
3x hoses (5 m long) and heat protection plate
0635 2042
testo-340-P08-09
15.02.2013
10:16
Seite 8
testo 340
We measure it.
Technical data
O2 measurement
0 to 25 Vol. %
±0.2 Vol. %
0.01 Vol. %
Adjustment
time t90
〈 20 sec
CO measurement (H2
compensated)
0 to 10.000 ppm
±10 ppm or ±10% of mv (0 to 200 ppm)
±20 ppm or ±5% of mv (201 to 2.000 ppm)
±10% of mv (2.001 to 10.000 ppm)
1 ppm
〈 40
sec
COlow measurement
(H2 compensated)
0 to 500 ppm
±2 ppm (0 to 39.9 ppm)
±5% of mv (remaining range)X
0.1 ppm
〈 40
sec
Meas. range
Accuracy ±1 digit
Resolution
X
data corresponds to 20°C ambient temperature. Additional
temperature coefficient 0.25% of reading/K.
NO measurement
0 to 4.000 ppm
±5 ppm (0 to 99 ppm)
±5% of mv (100 to 1.999 ppm)
±10% of mv (2.000 to 4.000 ppm)
1 ppm
〈 30
sec
NOlow measurement
0 to 300 ppm
±2 ppm (0 to 39.9 ppm)
±5% of mv (remaining range)
0.1 ppm
〈 30
sec
NO2 measurement*
0 to 500 ppm
±10 ppm (0 to 199 ppm)
±5% of mv (remaining range)
0.1 ppm
〈 40
sec
SO2 measurement*
0 to 5.000 ppm
±10 ppm (0 to 99 ppm)
±10% of mv (remaining range)
1 ppm
〈 40
sec
Temperature meas.
-40 to +1.200 °C
±0.5 °C (0 to +99 °C)
±0.5 % of mv (remaining range)
0.1 °C
Draught
measurement
-40 to +40 hPa
±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of mv (remaining range)
0.01 hPa
Differential pressure
measurement
-200 to 200 hPa
±0.5 hPa (-49.9 to 49.9 hPa)
±1.5 % of mv (remaining range)
0.1 hPa
Absolute pressure
measurement
600 to +1.150 hPa
±10 hPa
1 hPa
Probe type Type K (NiCr-Ni)
Derived parameters
Efficiency
0 to 120 %
0.1 %
Flue gas loss
0 to 99.9 %
0.1 %
Exhaust gas dewpoint
0 to 99.9 °C
CO2 measurement
0 to CO2 max.
0.1 °C
±0.2 Vol. %
0.1 Vol. %
〈
40 sec
(Calculated from O2)
*To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
Country permits BLUETOOTH® wireless transmission for testo
340
The BLUETOOTH® radio module used by Testo is permitted for the
following countries and may only be used in those countries, i.e. the
BLUETOOTH® wireless transmission may not be used in any other
country!
Europe including all EU member states
Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Great Britain, Greece, Hungary, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden and Turkey
European countries (EFTA)
Iceland, Liechtenstein, Norway, Switzerland
Non-European countries
Canada, USA, Japan, Ukraine, Australia, Columbia, El Salvador, Mexico,
Venezuela
testo-340-P08-09
15.02.2013
10:16
Seite 9
testo 340
We measure it.
Technical data
Measuring range extension
Single dilution, factor 5 (standard)
Meas. range
Accuracy
Resolution
CO measurement (H2 compensated)
700 ppm to 50.000 ppm
±10 % of mv (additional error)
1 ppm
COlow measurement (H2 compensated)
300 ppm to 2.500 ppm
±10 % of mv (additional error)
0.1 ppm
NO measurement
500 ppm to 20.000 ppm
±10 % of mv (additional error)
1 ppm
NOlow measurement
150 ppm to 1.500 ppm
±10 % of mv (additional error)
0,1 ppm
SO2 measurement
500 ppm to 25.000 ppm
±10 % of mv (additional error)
1 ppm
Dilution of all sensors, factor 2 (option, Part no. 0440 3350)
O2 measurement
When measuring range extension switched on, over all sensors:
±1 Vol.% additional error
0 to 25 Vol.%
(0 to 4.99 Vol.%)
±0.5 Vol.% additional error
(5 to 25 Vol.%)
0.01 Vol.%
CO measurement (H2 compensated)
700 ppm to 20.000 ppm
±10 % of mv (additional error)
1 ppm
COlow measurement (H2 compensated)
300 ppm to 1.000 ppm
±10 % of mv (additional error)
0.1 ppm
NO measurement
500 ppm to 8.000 ppm
±10 % of mv (additional error)
1 ppm
NOlow measurement
150 ppm to 600 ppm
±10 % of mv (additional error)
0.1 ppm
NO2 measurement
200 ppm to 1.000 ppm
±10 % of mv (additional error)
0.1 ppm
SO2 measurement
500 ppm to 10.000 ppm
±10 % of mv (additional error)
1 ppm
General technical data
Memory
Maximum
Per folder
Per site
User-defined
fuels
Regulated diaphragm
pump
Pump flow
Hose length
100 folders
Max. 10 sites
Max. 200 logs
The max. number of logs is determined by
the number of folders or sites
10 user-defined fuels incl. test gas as fuel
Display
Graphic display 160 x 240 pixels
Power supply
Battery block 3.7 V / 2.4 Ah
Mains unit 6.3 V / 2 A
Housing material
TPE PC
Protection class
IP40
Warranty
Analyzer
Rech. batt.
Sensors
Max. pos. press./flue gas
Max. neg. press./flue gas
0.6 l/min (regulated)
max. 7.8 m (corresponds to two probe
hose extensions)
+50 mbar
-200 mbar
Weight
960 g
Dimensions
283 x 103 x 65 mm
Storage temp.
-20 to +50 °C
Oper. temp.
-5 to +50 °C
2 years (excluding working parts, e.g.
sensors, sensor replacement filter)
1 year
CO, NO, COlow, NOlow, NO2, SO2: 1 year
O2: 1.5 years
OMNI
Novel Concept Emergent
PENTA
Thermal Mass
Gas Flow Meter
OMNI Telemetry Co.
5 Ellen Street Mississauga-L5m 1R8
Ontario, Canada
Telephone: +1 416 855 1942
Fax:
+1 416 907 9712
Email: info@omnitm.ca, Website: www.omnitm.ca
Datasheet OGF5400_PENTA
Applications
Characteristics
For application in industrial and commercial air/gas
flow metering
Compact water proof and explosion proof both
types are available
Preferred areas of use are:
Universal 90-260 V AC or 24 V DC input power,
solar power (optional)
Compressed air
Combustion air
Natural gas
Aeration air
Large graphic TFT LCD touch screen
Menu driven parameter display, setup and
configuration with win8 launcher
Digester/Bio-gas
Programmable parameters with password
protection
Vent line/flare headers
Modbus RS485 communication
Other specific gases
Data logging
Preferred customers:
Industrial sector, gas distribution and
supply organizations
Bulk customers, housing societies
Sub metering
Control line losses and leakage in supply
system
0 to 70 C ambient operating temperature range
0 to 180 C process temperature range
Process pressure up to 16 Bar
2-10 V DC and pulse output for flow
On site setup as per line size and other parameters
From 1” to 16” line sizes measurement
Stainless steel probe and shaft and fittings
Direct mass flow measurement of air and gases
Accuracy: 1%
High turndown: 100:1
Excellent low flow sensitivity
On site setup as per line size and type of gas
Temperature pressure compensation
TFT color touch screen
Win8 launcher
Very low pressure drop
Line size from 1” to 16”
OGF5400_PENTA
Page 2 of 9
Datasheet OGF5400_PENTA
Features
Specifications
OGF5400_PENTA is an intelligent solution for
accurate consumption measurement for compressed
air and gases. An affordable flow meter
OGF5400_PENTA is work according to the approved
calorimetric measuring principle.
In this process a heated sensor is cooled down by
the gas circulating around it. The flow-dependent
cooling-down is used as a measuring effect while
the degree of cooling-down is directly depending on
the passing air resp. gas mass. Therefore, an
additional pressure and temperature compensation
is not necessary.
Range: 0~63m/s
Accuracy: ±1% of reading ±0.5% of F.S
Turndown: 100:1
Response time: 3 sec., adjustable through damping
coefficient
Operating temperatures (Ambient): -10~70°C
Media temperature: 0~180°C, 0~250°C (optional)
Operating pressure: up to 16 Bar
Analog output: 2-10 V DC output for flow rate
Communication: Modbus protocol RS485
Pulse output: 1 pulse of unit value, Width 50 ms
Material: Sensor: 316L and Alloy C-276
Sensor support: 304 and 316L Ø19mm
IP protection: IP67
Humidity: 0~100% RH
Display: Graphic TFT color touch screen LCD for
parameters local monitoring, data logging, setup
and configuration
Power supply: SMPS 110-250 V AC/ 24 V DC
Due to its compact design it is possible to monitor
all compressed air systems from the compressor to
the smallest compressed air line (25mm to 50mm)
with the new affordable flow meter OGF5400-50.
New flow meters OGF5400_PENTA are available or
larger pipe diameters from DN 50 to DN 400. Apart
from compressed air also other gases like e. g.
nitrogen, oxygen and CO2 can be measured.
The built-in gas conversion coefficient list can be
used to correct when the flow meters used to
measure the non-air gases. The mounting for the
meters with the DN15-DN50 is pipe type, and it is
insertion type for the upstream pipe when the DN is
above 50mm.
The correction feature allows OGF5400_PENTA
accuracy to installer no effect when suppress the
range, this can help customers to reduce the stock
amount and change the range in field.
Volumetric flow ranges
Line
DN
m3/h
1”
25
90
2”
50
315
3”
75
765
4”
100
1,125
5”
125
1,935
6”
150
2,925
8”
200
4,410
10”
250
6,750
12”
300
9,900
16”
400
16,137
The intelligent OGF5400_PENTA use advanced ARM
MCU and TFT color touch screen display multiple
parameters and menu driven setup based on Win8
launcher. Including mass flow rate and totalized
mass in your choice of engineering units, and
features an intuitive and easy-to-use menu for
configuration and diagnostics. Changing ranges,
fluids, alarms, outputs, totalizes and engineering
units can be done from local touch screen, or PC, or
remotely with telemetry unit option. The unit of flow
rate can set to any engineering unit.
Mentioned flow rates are standard flows at 20 °C
and 1 Bar.
Power saving mode: For reducing power
consumption and enhancing touch screen life,
backlit of LCD will turned off after 10-minutes.
For large diameter pipes applications customized
OGF5400_PENTA gas flow meters are available on
customer request.
OGF5400_PENTA
The table above shows flow ranges up to 400 mm
pipe diameter at standard conditions in air. At other
standard conditions and in other gases flow ranges
are different.
Page 3 of 9
Datasheet OGF5400_PENTA
Ordering information
OGF5400_50F
OGF5400_50F: Low cost general purpose gas flow
metering unit complete with mounting flanges for
line size up to 2”.
OGF5400_PENTA_XXIEXL2AR
XX:
Insertion type from 2” to 12” with DN
suffix 50 to 300
I:
Insertion type
F:
Flange type
EX:
IP67 Explosion Proof housing
L2:
High temperature version up to 250 C.
A:
Power supply (SMPS) 90-250 V AC
D:
Aux. power supply 24 V DC
R:
Remote telemetry
Accessories
Aux. power supply: 24 V DC
Solar charging: Solar/ Aux. charging unit with
backup battery
Communication module: Modbus RS485
Remote telemetry: GSM/ GPRS based remote
monitoring and setup
Disclaimer
The information contained in this document is
subject to change without notice.
OMNI Telemetry Co. makes no representations or
warranties with respect to the contents hereof, and
specifically disclaims any implied warranties of
merchantability or fitness for a particular purpose.
©2008 OMNI Telemetry Co.
All rights reserved.
OGF5400_PENTA
Page 9 of 9
OMNI
Novel Concept Emergent
SMART
Steam Flow
Computers
OMNI Telemetry Co.
5 Ellen Street Mississauga-L5m 1R8
Ontario, Canada
Telephone: +1 416 855 1942
Fax:
+1 416 907 9712
Email: info@omnitm.ca, Website: www.omnitm.ca
Datasheet FCU5400_SMART
Applications
Characteristics
For application in the process engineering,
suit for liquids, vapor, or gases
Compact water proof and explosion proof
both types are available
Preferred areas of use are:
Universal 90-260 V AC or 24 V DC
input power, solar power (optional)
Large graphic TFT LCD touch screen
Process engineering
Menu driven parameter display, setup and
configuration with win8 launcher
Chemical industry
Textiles
Power plants
Programmable parameters with password
protection
Compressor stations
Modbus RS485 communication
Pharmaceuticals
Data logging
Food & beverage
0 to 70 C ambient operating temperature
range
Sugar
2-10 V DC and pulse output for flow
On site setup as per line size and other
parameters
Remote telemetry (optional)
•
•
•
•
•
Flow rate indicator & totalizer
Batch controller
Flow rate controller
Multiple inputs
Computer unit for multi variable
FCU5400_SMART
•
On site setup as per line size
•
•
•
•
Temperature compensation
Pressure compensation
TFT color touch screen
Win8 launcher
Page 2 of 9
Datasheet FCU5400_SMART
Features
Specifications
Feature Rich and Flexible
General
The SMART FCU5400 process indicator
and controller boasts specifications and
functionality that clearly makes it one of the
most advanced process meters available.
Its TFT touch screen, advanced math
functions, function keys, and optional
modules are only a few of the features you
will find on the SMART FCU5400.
Display: High contrast TFT color
touch screen
Flow rate: 12 digits, Totalizing: 12 digits
Display update rate: 100 ms
Panel: IP65 water proof
Password: Password restrict modification of
programmed settings
EEPROM: Data retention up to 40 years
Power options: 90-260 V AC 50/60 HZ,
12 watts or 24 V DC
Environmental: Operating temperature
range: -10 to 65 C. Storage temperature
range: -40 to 85 C. Relative humidity: 0 to
90% non-condensing
Connections: Removable screw
terminal blocks accept 12 to 22 AWG
wire Mounting: Four panel mounting
bracket assemblies for wall mounting
Warranty: 1 year parts & labor
Precise, Accurate, and
more informative
SMART FCU5400 large TFT LCD display
will provide you with a highly accurate and
precise view of all parameters. It 13-bit A/D
is accurate to 0.05% FS 1 count.
Configurable
The main display can be programmed to
indicate m3/h, TPH, Kg/h, and auto decimal
converter. Configuration and setup is by
menu driven parameter.
Environmentally tough
Extra bright graphic LCD, readable in open
environment also. Water proof IP65
housing.
Easy to use
The user friendly manue based on win-8
launcher makes the SMART FCU5400
easy to setup & program. No jumpers to
set, or potentiometer to adjust. All setup
and programming is done via the front
touch screen. A unique password
protection is help to maintain the reliability
of the programming at every level.
Customized options
Due to boot-rom firmware up gradation, the
SMART FCU5400 can be programed as:
• Flow rate indicator & totalizer
• Batch controller
• Flow rate controller
• Multiple inputs
• Computer unit for multi variable
Process input
Input: 0-20 mA, 4-20mA, 0-10 V DC, 2-10
V DC
Math function: Linear, square root,
or
programmable
exponent,
multipoint linearization for gas flow
Programmable exponent: 0.01 to 1.99
Low range cutoff: Programmable low
range Decimal point: Auto decimal up to 3
digits Calibration range: Minimum span:
0.15 mA or 0.10 V
Input Impedance: Voltage: 1
M , Current: 5
Analog output
Output source: Process variable
Scaling range: 4.0 to 20.0 mA for
any display range
Calibration: Factory calibrated
Accuracy: 0.1% FS 0.004 mA
Serial Communication
Address: 1-32
Baud rate: 9600
Data: 8 bit (1 start bit, 1 stop bit), parity
none
Power saving mode: For reducing power
consumption and enhancing touch screen
life, backlit of LCD will turned off after 10minutes.
FCU5400_SMART
Page 3 of 9
Datasheet FCU5400_SMART
Ordering information
FCU5400_SMART_XXXTPF
XXX: Line size, DN suffix 50 to 300
T:
With temperature sensor
P:
Pressure transmitter
F:
DP type flow transmitter, refer to
our OSF5400 transmitter range,
otherwise please specify
Accessories
Aux. power supply: 24 V DC
Solar charging: Solar/ Aux. charging
unit with backup battery
Communication module: Modbus
RS485 Remote telemetry: GSM/ GPRS
based remote monitoring and setup
Disclaimer
The information contained in this document is
subject to change without notice.
OMNI Telemetry Co. makes no representations
or warranties with respect to the contents hereof,
and specifically disclaims any implied warranties
of merchantability or fitness for a particular
purpose.
©2008 OMNI Telemetry Co.
All rights reserved.
FCU5400_SMART
Page 9 of 9
SDS M1200-08
VORTEX
FLOWMETER
MODEL
EF73
RELIABLE FLOW MEASURING SYSTEM FOR STEAM, AIR AND WATER
Features
High-performance vortex flowmeter with robust
sensor for highly accurate volume or mass flow
measurements of saturated and superheated
steam, air and water.
1. DSC (Differential Switched Capacitance) sensor
offers a wide measuring range, with a high
resistance to thermal shock, vibration and water
hammer.
2. Integrated flow computer calculates mass flow from
measured volume flow and temperature variables.
3. Capable of simultaneous pulse (interval) and
analog (instantaneous) output.
4. Requires no maintenance, has no moving parts,
and experiences no zero point drift.
5. Low pressure drop through body.
Specifications
Meter Body / Sensor
Model
5.5
Between Flanges (Flangeless)
Flanged
15, 25, 40, 50, 80,
15, 25, 40, 50, 80, 100,
100, 150
150, 200, 250, 300
Connection Compatibilities
See details in the Dimensions section
Operating Pressure Range
(MPaG)
0 – 4.96 (See the table to the right for details)
-2001) – +400 (See the table to the right for details)
Steam, Air, Water
Temperature Range (°C)
Applicable Fluids2) 3)
Volume Flow
Mass Flow
Repeatability
Gas/Steam: ± 1% of reading (Re > 20 000),
± 1% of full scale (Re: 4 000 – 20 000)
Liquid: ± 0.75% of reading (Re > 20 000)
± 0.75% of full scale (Re: 4 000 – 20 000)
Saturated ± 2% of reading4) (Re > 20 000)
Steam: ± 2% of full scale4) (Re: 4 000 – 20 000)
ASME 300
4.5
4.0
DIN PN 40
3.5
3.0
DIN PN 25
2.5
JIS 20K
2.0
1.6
1.5
ASME 150
DIN PN 16
1.0
DIN PN 10, JIS 10K
0.5
0
-200
Mounting Position
At least 1G in all directions (10 – 500 Hz)
No restriction with regards to meter accuracy
1) Subject to the limitations of fluid freezing point 2) For superheated steam and air, an external
pressure sensor and flow computer may be required if inlet pressure fluctuates
3) Do not use for toxic, flammable or otherwise hazardous fluids 4) ±2.3% for remote version
Transmitter
Explosion Class
Non-explosion proof
Ambient Temperature
Ingress Resistance
Compact Type: -40 – +70 °C
Remote Type: -40 – +80 °C
Power Source
12 – 36 V DC (24 V DC recommended)
Power Consumption
Power Line Connection
1.2 W DC (including sensor)
G(PF)a/B
2-wire System (2-conductor, shielded, at least 1.25 mm2)
Field Wiring
Load Line Resistance
100
Maximum 550Ω at 24 V
To avoid abnormal operation, accidents or serious injury, DO NOT use
this product outside of the specification range. Local regulations may
restrict the use of this product to below the conditions quoted.
200
300
400
Temperature (°C)
1 MPa = 10.197 kg/cm2
Reynolds Number (Re) Calculation:
dxV
d = pipe diameter V = velocity
Re= ———
ν
ν = viscosity
Transmitter Terminals
A
+ 1 2
A: Power supply/
current output
B: Optional frequency
output
C: Ground terminal
(for remote version)
B
+ 3 4
C
IP 67 (NEMA 4X)
Frequency (pulse) output: Open collector pulse (passive)
Analog output: 4 – 20 mA DC
Output
0
-100
Within 0.25% of reading
Vibration Resistance
CAUTION
Maximum Operating Pressure
5.0
4.96
Pressure (MPaG)
Size (mm)
Accuracy
Pressure/Temperature Operating Range
EF73
Connection
Display
I
48.25 kg/h
3702.6 t
Esc
-
+
E
Sample
display
Specifications
No.
Description
q Meter Body
w Bluff Body
DSC Sensor (wetted parts)
e
DSC Sensor (non-wetted parts)
r Pipe Stand
t Transmitter Housing
y Gasket
u Nameplate
i Mounting Kit**
o Remote Transmitter Mount***
!0 Connecting Cable (30 m)***
Material*
Cast Stainless Steel
Cast Stainless Steel
Stainless Steel (DIN 1.4435)
Stainless Steel (DIN 1.4301)
Cast Stainless Steel
Die-cast Aluminum
Graphite
—
—
Die-cast Aluminum
—
JIS*
SCS16A
SCS16A
SUS316L
SUS304
SCS13A
—
—
—
—
—
—
ASTM/AISI
A351 Gr. CF3M
A351 Gr. CF3M
AISI316L*
AISI304*
A351 Gr. CF8
—
—
—
—
—
—
* Equivalent
** Flangeless model only, to ensure concentric installation; includes centering rings, threaded
bolts, nuts, washers and flange gaskets
*** Remote version only, see next page
Piping Installation
Required Length of Straight Piping
Element
No Flow Conditioner
Mounting Position
A
With Flow Conditioner
(Rectifier)
-
Esc
+
E
Flow Conditioner
B
Control Valve
50D
A
-
Esc
+
E
5D
5D
B
8D
A
+
1. High-temperature Fluids
For high-temperature fluids (steam,
condensate), positions A, B or C
should be selected to protect the
transmitter from heat.
5D
B
Esc
-
E
C
-
Esc
+
E
Flow Conditioner
Concentric
Reducer
(Convergent-Pipe)
15D
A
Esc
-
+
E
2D
5D
B
8D
A
5D
B
Esc
-
+
E
Flow Conditioner
Concentric
Diffuser
(Expansion-Pipe)
5D
B
Esc
-
+
E
2D+5h
8D
A
5D
B
Esc
-
+
E
Flow Conditioner
Eccentric
Reducer
(Convergent-Pipe)
25D
A
5D
B
Esc
-
+
E
5D
8D
A
5D
B
Esc
-
+
E
Flow Conditioner
One 90 Elbow
or T-piece
20D
A
5D
B
Esc
-
+
E
2D
8D
A
5D
B
Esc
-
+
E
Flow Conditioner
Two 90 Elbows
(2-Dimensional)
25D
A
5D
B
Esc
-
+
E
5D
8D
A
5D
B
Esc
-
+
E
Flow Conditioner
Two 90 Elbows
(3-Dimensional)
40D
A
5D
B
Esc
-
+
E
5D
8D
A
5D
B
Esc
-
+
-
D
Esc
+
E
2. Water
To make sure the pipes are
completely flooded with Water,
position C is recommended.
Pressure Measurement Points
h
18D
A
There is no restriction for mounting
position (A – D) in regards to meter
accuracy. However, special care is
recommended for the following flow
mediums:
E
If a pressure measuring point is
installed after the device, ensure
that there is a large enough
distance between the device and
the measuring point so that there
are no negative effects on vortex
formation in the sensor.
PT
Downstream
3 – 5D
c
+
E
D = Nominal Diameter
Pipeline Insulation
The pipe stand serves
as a radiator and
protects the electronics
from overheating.
Therefore, ensure that
sufficient surface area
remains exposed.
Be sure not to insulate
passed the level marked
“max.” on the pipe stand.
-
Esc
+
E
Ensuring Steam Quality
Wet steam has a higher density than saturated steam.
Since the flowmeter mass flow calculations are based on
saturated steam density, the actual mass flow of wet
steam will be higher than shown by the flowmeter. The
upstream installation of a separator (DC3S) is suggested
to ensure steam quality and flowmeter accuracy.
The proper separation and drainage of condensate is a
recommended practice for all steam applications.
50D
Combination Pipe
(Elbows &
Eccentric
Reducer, etc.)
Flow Conditioner
50D
A
Esc
-
+
E
5D
B
5D
8D
A
Esc
-
+
E
5D
B
Wet
Steam
Saturated
Steam
c
+
E
A = Upstream, B = Downstream, D = Nominal Diameter
DC3S separator with
built-in steam trap
SDS M1200-08
Dimensions
EF73
¡EF73
Remote Version
Weight**
(kg)
17
276
246
3.0
28
286
256
3.2
82
42
294
264
3.8
92
54
301
271
4.1
80
127
80
315
285
5.5
100
157
105
328
298
6.5
150
216
157
354
324
9.0
15
45
25
64
40
65
EF73
Size
115
φ85
Remote
15
277
247
5.5
25
284
254
7.5
292
262
11
50
299
269
13
80
312
282
21
324
294
28
348
318
52
377
347
65 (77)
40
L
250
300
300
250
380
380
404
374
93 (110)
300
450
450
427
397
144 (163)
TEMP 2
TEMP 3
5
6
7
8
RD
TEMP 1
4
BU
– 5 VA
3
PK
+ 5 VA
2
GY
1
WT
GROUND
Remote Transmitter to Sensor
Wiring
YL
211
DIFF –
Pipe Mounted*
6
7
TEMP 2
RD
BU
5
TEMP 1
8
TEMP 3
PK
4
– 5 VA
GY
3
+ 5 VA
YL
2
GROUND
GN
1
DIFF –
* Requires optional parts
DIFF +
Remote transmitter weight: 3.5 kg
WT
100
123
BN
100
133
348
221
250
200
Other standards available, but weight may vary
* Weight is for compact version
( ) ASME Class 300 RF
20 – 80 mm pipe
Remote Transmitter
Wall Mounted
200
300RF
Weight*
(kg)
Compact
200
L
H1
ASME Class
150RF
H1
H1
149
(mm)
L
150
154
141
Flanged
Remote Version
100
¡EF73
65
GN
Flanged
Compact Version
L
* Compatible with ASME Class 150, 300, JIS 10K/20K, and DIN 2501
PN10/16, 25/40 flange standards
** Weight is for compact version
¡EF73
154
141
Remote
φd
50
H1
d
D
L
Compact
φD
Size
115
φ85
H1
149
(mm)
H1
DIFF +
154
141
Flangeless*
BN
Flangeless
Compact Version
Options
q Pipe Mounting Kit
w Sunshade for
Transmitter
e Flow Conditioner
Suitable for
20 – 80 mm pipe.
(Includes bracket,
threaded bolts and
nuts.)
SDS M1200-08
Flow Rate for Saturated Steam
¡EF73
Flangeless
(Unit: kg/h)
Size (mm)
Pressure
(MPaG)
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
0.05
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.2
1.5
2.0
2.5
3.0
4.4
5.0
6.0
6.9
7.6
8.3
8.9
9.5
10
11
11
12
14
15
17
19
30
40
58
76
94
112
130
147
165
182
199
234
286
373
460
549
13
14
17
20
22
24
25
27
28
30
31
34
37
42
47
51
140
183
267
350
432
512
593
673
752
832
911
1069
1306
1702
2101
2505
33
38
45
52
58
63
67
72
76
80
83
90
100
114
126
137
325
424
620
811
1000
1187
1373
1558
1743
1927
2110
2476
3025
3942
4866
5801
53
61
73
84
93
101
109
116
123
129
135
146
162
184
205
224
527
689
1006
1316
1623
1927
2229
2529
2828
3127
3424
4018
4909
6397
7897
9413
119
136
165
188
209
228
245
261
276
290
303
328
363
414
460
502
1187
1551
2263
2962
3652
4336
5015
5691
6364
7035
7705
9042
11046
14394
17768
21180
203
232
280
320
356
387
417
444
469
493
516
559
618
706
784
856
2023
2643
3856
5047
6223
7388
8545
9697
10843
11987
13128
15406
18820
24525
30274
36087
¡EF73
15
25
40
50
80
100
150
Min.
454
4531
111.6
519
5919
120.4
627
8636
133.7
717
11303 143.7
796
13936 151.9
867
16545 158.9
932
19136 165.0
993
21714 170.5
1050
24282 175.4
1104
26843 179.9
1156
29398 184.1
1252
34499 191.6
1384
42143 201.4
1579
54918 214.9
1755
67791 226.1
1916
80810 235.7
1 MPa = 10.197 kg/cm2
Flanged
15
Size (mm)
Pressure
Min. Max.
(MPaG)
21
3.1
0.05
28
3.5
0.1
41
4.3
0.2
54
4.9
0.3
66
5.4
0.4
79
5.9
0.5
91
6.3
0.6
103
6.7
0.7
116
7.1
0.8
128
7.5
0.9
140
7.8
1.0
164
8.5
1.2
201
9.4
1.5
262
11
2.0
323
12
2.5
386
13
3.0
Temp
(°C)
Max.
(Unit: kg/h)
25
40
50
80
100
150
200
250
300
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Temp
(°C)
9.4
11
13
15
17
18
20
21
22
23
24
26
29
33
37
40
108
142
207
271
334
397
459
521
583
645
706
829
1012
1319
1629
1942
27
31
37
43
47
52
56
59
63
66
69
74
82
94
104
114
267
349
510
667
823
977
1130
1282
1434
1585
1736
2038
2489
3244
4005
4774
45
52
62
71
79
86
92
98
104
109
114
124
137
156
173
189
446
583
850
1113
1372
1629
1885
2139
2392
2644
2896
3398
4151
5410
6678
7961
101
115
139
159
176
192
207
220
233
245
256
277
306
350
388
424
1001
1308
1909
2498
3080
3657
4230
4800
5368
5934
6499
7626
9316
12140
14986
17864
174
199
240
275
305
332
357
381
403
423
443
480
530
605
672
734
1735
2266
3307
4328
5336
6335
7328
8315
9298
10279
11257
13211
16138
21030
25960
30945
396
452
546
624
693
755
812
865
915
962
1007
1091
1205
1376
1529
1669
3947
5156
7523
9846
12140
14412
16669
18915
21152
23383
25609
30053
36712
47839
59054
70394
759
867
1047
1198
1330
1450
1559
1661
1756
1846
1932
2093
2313
2641
2934
3203
7577
9897
14442
18901
23304
27667
32000
36311
40605
44887
49160
57690
70473
91835
113363
135132
1196
1367
1651
1889
2097
2285
2457
2618
2768
2910
3046
3299
3646
4162
4625
5049
11945
15603
22767
29796
36737
43614
50445
57241
64010
70761
77497
90944
111095
144769
178705
213023
1715
1960
2368
2709
3008
3277
3524
3754
3970
4174
4368
4732
5230
5970
6633
7242
17133
22380
32655
42738
52694
62558
72356
82103
91813
101496
111158
130446
159349
207649
256326
305549
111.6
120.4
133.7
143.7
151.9
158.9
165.0
170.5
175.4
179.9
184.1
191.6
201.4
214.9
226.1
235.7
1 MPa = 10.197 kg/cm2
Flow Rate for Air and Water
(Unit: m3/h)
Model
Fluid
Size (mm)
15
25
40
50
80
100
150
200
250
300
EF73 Flangeless
Air (0 °C, atmospheric pressure)
Water (20 °C)
Min.
Max.
Min.
Max.
6.9
0.19
35
4.1
19
0.41
161
12
44
1.11
374
31
72
1.80
606
50
163
4.04
1365
113
279
6.88
2326
191
625
15.4
5210
428
–
–
–
–
–
–
–
–
–
–
–
–
EF73 Flanged
Air (0 °C, atmospheric pressure)
Water (20 °C)
Min.
Max.
Min.
Max.
4.9
0.16
24
2.9
15
0.32
125
8.9
36
0.91
307
26
61
1.52
513
43
138
3.41
1151
95
239
5.90
1995
164
544
13.5
4538
373
1045
25.8
8712
715
40.6
1648
13735
1127
2364
58.3
19700
1617
SDS M1200-08 Rev. 5/2012
Products for intended use only.
Specifications subject to change without notice.