Phone: +92 (0) 300 8220135 +92 (0) 305 5552343 Mail: info@espire.com.pk bfz gGmbH - International Division Training & Development Centers of the Bavarian Employers´Associations Internet: www.espire.com.pk Specifications of Available Energy Monitoring Equipment No. Equipment Model 1 3 Phase Power Analyzer Fluke 1730, Fluke Corporation USA 2 Flue Gas Analyzer Testo 320, Testo GmbH Germany 3 Flue Gas Analyzer Testo 340, Testo GmbH Germany 4 Compressed Air, Gas Thermal Mass Flow Meter OGF5400_PENTA, Omni Telemetry Co. Canada 5 Steam Flow Meter OSF/FCU 5400, Omni Telemetry Co. Canada 6 Steam Flow Meter Vortex Flow Meter TLV -EF-73, TLV Co. Japan Fluke 1730 Three-Phase Electrical Energy Logger Technical Data Energy logging is now within your reach— discover where you’re wasting energy, optimize your facility’s energy use and reduce your bill. The new Fluke 1730 Three-Phase Electrical Energy logger introduces a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed; from the service entrance to individual circuits. Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill. • Key measurements: voltage, current, power, power factor and associated values enable energy saving strategies to be implemented. • Bright, color touch screen: perform convenient in-the-field analysis and data checks with full graphical display. • Comprehensive logging: all measured values are automatically logged and can be reviewed during logging and before downloading for onthe-go analysis. More than 20 separate logging sessions can be stored on the instrument. • Optimized user interface: quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty. • Complete ‘in-the-field’ setup through the front panel: no need to return to the workshop for download and setup or to take a computer to the electrical panel. • Wide range power: power instrument directly from the measured circuit eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels. • Two USB ports: one for PC connection and another for fast, simple download to standard USB thumb drives, or other USB devices. • Compact size: designed to fit in tight spaces and panels. • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream. • Optimized measurement accessories: flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces. • Battery life: four-hour operating time (backup time) per charge on lithium-ion battery. • Security: safeguard against theft with a Kensington lock. • All new, Energy Analyze application software: download, analyze and automated reporting for a complete picture of energy saving potential. Applications Power and energy logging When a piece of equipment is operated it instantaneously consumes a specific amount of power in watts (W) or kilowatts (kW). This power is accuDiscover how much energy individual pieces of mulated over the operating time and expressed as equipment are consuming when they are operatenergy consumed in kilowatt hours (kWh). Energy ing at minimum and maximum capacity. Check is what your electric utility charges for; there will capacity of circuits prior to adding additional be a standard charge from the utility per kilowatt loads (various standards exist for this process; hour. Utilities may have other additional charges, in the US the NEC 220-87 is the recommended standard). Load studies can also identify situations such as peak demand, which is the maximum power demand over a defined period of time, where you may be exceeding the allowable load often 15 or 30 minutes. There may also be power on the circuit or when an agreed peak demand factor charges, which are based on the effects of applies from the utility. For convenience, some load studies simply measure current which makes the inductive or capacitive loads in the facility. installation of the measuring equipment quick and Optimizing peak demand and power factor often results in lower monthly electricity bills. The easy. It is often recommended that load surveys 1730 Three Phase Electrical Energy logger has be performed for 30 days so that all typical load the capability to measure and characterize these conditions are encountered during the test. effects enabling you to analyze the results and save money. Energy surveys Users often ask where measurements should be Simplified load studies taken for an energy survey. The answer is mulFor situations where it’s either difficult or impractiple points within the facility. Start at the main tical to make a voltage connection the simple load service feeders; compare the power and energy study feature allows users to perform a simplified measured here with the readings from the utilload study by measuring current only. The user ity meter to ensure you’re receiving the correct can enter the nominal expected voltage to create charges. Then move downstream to the larger loads; these should be easy to identify by the cur- a simulated power study. For accurate power rent rating of the electrical panels downstream of and energy studies it is required to monitor both voltage and current but this simplified method is the service entrances. Measuring at many points useful in certain circumstances. will allow a full picture of energy usage across the facility to be developed. The next question users typically have is how long an energy survey should last. This of course depends on the facility, but it is recommended that you measure for a period that matches a typical facility activity period. If the facility operates over a five day work week with down time on the weekend, a seven day survey will most likely capture typical conditions. If the facility operates at a constant level for 24 hours a day, 365 days a year, a single day could be reasonably representative as long as you avoid a period where there may be planned maintenance. To capture a full picture of the facilities energy usage it is not necessarily required to have measurements made simultaneously at every consumption point in the facility. To get a comprehensive picture, spot measurements can be made and then compared on a sliding time timescale. For example, you could compare the service entrance results from a typical Tuesday between 6:00 am and 12:00 pm with those of a larger load in the facility. Typically there will be some correlation between these profiles. Load studies 2 Fluke Corporation Fluke 1730 Three-Phase Electrical Energy Logger Specifications Accuracy Parameter Voltage iFlex1500-12 Current: Direct input iFlex3000-24 iFlex6000-36 i40s-EL clamp Frequency Aux input Voltage Min/Max Current Min/Max Cosϕ/DPF Power factor THD on voltage THD on current Range Resolution 1000 V 150 A 1500 A 300 A 3000 A 600 A 6000 A 4A 40 A 42.5 Hz to 69 Hz ± 10 V dc 1000 V defined by accessory 0 <= Cosϕ <=1 0 <= PF <=1 1000 % 1000 % 0.1 V 0.1 A 1A 1A 10 A 1A 10 A 1 mA 10 mA 0.01 Hz 0.1 mV 0.1 V defined by accessory 0.01 0.01 0.1 % 0.1 % Intrinsic Accuracy at Reference Conditions (% of Reading + % of Full Scale) ± (0.2 % + 0.01 %) ± (1 % + 0.02 %) ± (1 % + 0.02 %) ± (1 % + 0.02 %) ± (1 % + 0.02 %) ± (1.5 % + 0.03 %) ± (1.5 % + 0.03 %) ± (0.7 % + 0.02 %) ± (0.7 % + 0.02 %) ± (0.1 %) ± (0.2 % + 0.02 %) ± (1 % + 0.1 %) ± (5 % + 0.2 %) ± ± ± ± 0.025 0.025 (2.5 % ± 0.05 %) (2.5 % ± 0.05 %) Intrinsic uncertainty ± (% of reading + % of range)1 Parameter Influence iFlex1500-12 iFlex3000-24 quantity 150A/1500A 300A/3000A Active power P PF ≥ 0.99 1.2 % + 1.2 % + 0.005 % 0.0075 % 0.5 <PF <0.99 1.2 % + 7 x 1.2 % + 7 x (1-PF) (1-PF) +0.005 % + 0.0075 % Apparent power S, S fund. 0 ≤ PF ≤ 1 1.2 % + 1.2 % + 0.005 % 0.0075 % Reactive power N, Q fund. 0 ≤ PF ≤ 1 2.5 % of measured apparent power Additional uncertainty in % U >250 V 0.015 % 0.0225 % of range1 1 iFlex6000-36 600/6000A 1.7 % + 0.0075 % 1.7 % + 7 x (1-PF) + 0.0075 % 1.7 % + 0.0075 % i40s-EL 4A/40A 1.2 % + 0.005 % 1.2 % + 10 x (1-PF) + 0.005 % 1.2 % + 0.005% 0.0225 % 0.015 % Range = 1000 V x Irange Reference conditions: Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 % Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %. Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10 % of Irange Primary conductor of clamps or Rogowski coil in center position Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C 3 Fluke Corporation Fluke 1730 Three-Phase Electrical Energy Logger Electrical specifications Power supply Voltage range Power consumption Efficiency Maximum no-load consumption Mains power frequency Battery On-battery runtime Charging time Data acquisition Resolution Sampling frequency Input signal frequency Circuit types THD Averaging period Demand interval Data storage Memory size Logging period 100 V to 500 V using safety plug input when powering from the measurement circuit 100 V to 240 V using standard power cord (IEC 60320 C7) Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) ≥ 68.2 % (in accordance with energy efficiency regulations) < 0.3 W only when powered using IEC 60320 input 50/60 Hz ± 15 % Li-ion 3.7 V, 9.25 Wh, customer-replaceable Four hours in standard operating mode, up to 5.5 hours in power saving mode < 6 hours 16-bit synchronous sampling 5120 Hz 50/60 Hz (42.5 to 69 Hz) 1-ϕ, 1-ϕ IT, Split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, Currents only (load studies) THD for voltage and current is calculated using 25 harmonics User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min User selectable: 5 min, 10 min, 15 min, 20 min, 30 min Internal flash memory (not user replaceable) Typical 20 logging sessions of 10 weeks with 10-minute intervals1 Averaging period 1 second 5 seconds 10 seconds 30 seconds 1 minute 5 minutes 10 minutes 15 minutes 30 minutes Interfaces USB-A USB-mini Extension port Voltage inputs Number of inputs Maximum input voltage Input impedance Bandwidth (-3 dB) Scaling Measurement category Current inputs Number of inputs Input voltage Rogowski coil input Range Bandwidth (-3 dB) Scaling Recommended for 20 sessions 3 hours 15 hours 28 hours 3.5 days 7 days 5 weeks 10 weeks 3.5 months 7 months File transfer via USB flash drive, firmware updates Max. current: 120 mA Data download device to PC Accessories 4 (3 phases and neutral) 1000 Vrms, CF 1.7 10 MΩ 2.5 kHz 1:1, 10:1, 100:1, 1000:1 and variable 1000 V CAT III/600 V CAT IV 3, mode selected automatically for attached sensor Clamp input: 500 mVrms/50 mVrms; CF 2.8 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range 1 A to 150 A/10 A to 1500 A with thin iFlex flexible current probe, 12 inches 3 A to 300 A/30 A to 3000 A with thin Flex flexible current probe, 24 inches 6 A to 600 A/60 A to 6000 A with thin iFlex flexible current probe, 36 inches 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL 1.5 kHz 1:1 and variable 1 The number of possible logging sessions and logging period depends on user requirements. 4 Fluke Corporation Logging Period for 1 session 2.5 days 12 days 24 days 10 weeks 20 weeks 2 years > 2 years > 2 years > 2 years1 Fluke 1730 Three-Phase Electrical Energy Logger Auxiliary inputs Number of inputs Input range Scale factor (available 2014) Displayed units (available 2014) Environmental specifications Operating temperature Storage temperature Operating humidity Operating altitude Storage altitude Enclosure Vibration Safety EMI, RFI, EMC Electromagnetic compatibility Radio frequency emissions Temperature coefficient General specifications Color LCD display Warranty Dimensions Weight External protection 5 Fluke Corporation 2 0 to ± 10 V dc, 1 reading/s Format: kx + d user configurable User configurable (7 characters, for example, °C, psi, or m/s) -10 °C to +50 °C (14 °F to 122 °F) -20 °C to +60 °C (−4 °F to 140 °F) 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH 40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) 12,000 m IP50 in accordance with EN60529 MIL 28800E, Type 3, Class III, Style B IEC 61010-1: Overvoltage CAT IV, Measurement 1000 V CAT III/600 V CAT IV, Pollution Degree 2 EN 61326-1: Industrial Applies to use in Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment) IEC CISPR 11: Group 1, Class A 0.1 x accuracy specification/°C 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel 1730 and power supply: Two-years (battery not included) Accessories: One-year Calibration cycle: Two-years 1730: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) 1730 with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) 1730: 1.1 kg (2.5 lb) Power supply: 400 g (0.9 lb) Holster, Kensington lock slot Fluke 1730 Three-Phase Electrical Energy Logger 1500-12 iFlex Flexible Current Probe specifications Measuring range Nondestructive current Intrinsic error at reference condition* Accuracy 1730 + iFlex Temperature coefficient over operating temperature range Working voltage Probe cable length Probe cable diameter Minimum bending radius Output cable length Weight Transducer cable material Coupling material Output cable Operating temperature Temperature, non-operating Relative humidity, operating IP rating Warranty 1 to 150 A ac / 10 to 1500 A ac 100 kA (50/60 Hz) ± 0.7 % of reading ± (1 % of reading + 0.02 % of range) 0.05 % of reading/°C 0.09 % of reading/°F 1000 V CAT III, 600 V CAT IV 305 mm (12 in) 7.5 mm (0.3 in) 38 mm (1.5 in) 2 m (6.6 ft) 115 g TPR POM + ABS/PC TPR/PVC -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176°F) -40 °C to +80 °C (-40 °F to 176 °F) 15 % to 85 % non-condensing IEC 60529:IP50 One-year *Reference condition: • Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 % • Primary conductor in center position Ordering information 1730/BASIC Three-Phase Electrical Energy logger (excludes current probes). 1730/US Portable Energy Logger US version 1730/EU Portable Energy Logger EU version 1730/INTL Portable Energy Logger INTL version Accessories i1730-flex1500 iFlex flexible current probe 1500A 12 inch i1730-flex3000 iFlex flexible current probe 3000A 24 inch i1730-flex6000 iFlex flexible current probe 6000A 36 inch i40s-EL i40s-EL Clamp-on Current Transformer i1730-flex1500/3pk iFlex flexible current probe 1500A 12 inch, 3 pack i1730-flex3000/3pk iFlex flexible current probe 3000A 24 inch, 3 pack i1730-flex6000/3pk iFlex flexible current probe 6000A 36 inch, 3 pack i40s-EL/3pk i40s-EL Clamp-on Current Transformer, 3 pack 1730-TL0.1M Test Lead Set; 1000 V CAT III, straight plug; 0.1 m; silicone; red/black 1730-TL2M Test Lead Set, 1000 V CAT III; straight plug; 2 m; PVC red/black 3PHVL-1730 Cable Assembly, Voltage Test Lead 3-Phase+N C1730 1730 Soft Case WC100 Color Localization Set 1730-Hanger Hanging strap 1730-Cable AUX input cable Fluke. The Most Trusted Tools in the World. Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2013 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 8/2013 4314073B_EN Pub ID: 12028-eng Rev. 01 Modification of this document is not permitted without written permission from Fluke Corporation. 6 Fluke Corporation Fluke 1730 Three-Phase Electrical Energy Logger testo-340-P01 15.02.2013 10:09 Seite 1 We measure it. Flue gas analyzer for industry testo 340 – Portable measuring instrument for industrial emission measurement O2 Measuring range extension for unrestricted measurement at CO high gas concentrations Flue gas analysis with up to 4 gas sensors – freely CO l o w configurable Large selection of probes NO Bluetooth interface Convenient measurement data management NO l o w TÜV-tested /EN norm NO 2 SO 2 The handy, easy-to-operate emission measuring instrument The unique measuring range extension allows unrestricted testo 340 is the right tool for many different emission measurements to be carried out even at high gas measurements. The compact design and the reliable concentrations. The testo 340 is equipped with an O2 technology make it the ideal measuring instrument for sensor as standard. Three further gas sensors can be commissioning, service and maintenance work and in test configured individually, in order to be able to adapt the measurements on industrial burners, stationary industrial instrument optimally to the respective measurement task. engines, gas turbines and thermal processes. www.testo.com testo-340-P02-03 15.02.2013 10:11 Seite 2 testo 340 We measure it. Product properties Automatic sensor protection at high gas concentrations Thanks to the automatic measuring range extension, the measuring range of your CO, COlow, NO, NOlow or SO2 sensor is extended 5-fold. The sensor is placed under no greater strain at high gas concentrations than at low concentrations. The automatic sensor protection protects the sensor from overload without terminating the measurement. Optionally, the measuring range of all sensors in the instrument can be simultaneously extended by a factor of 2. Measurement up to e.g. max. 50,000 ppm (CO), or max. 20,000 ppm (NO), or max. 25,000 ppm (SO2), without overloading the sensor. Space for 4 gas sensors testo 340 is fitted with an O2 sensor as standard. Three additional toxic gas sensors such as CO, COlow, NO, NOlow, NO2 oder SO2 can be selected by the user. This guarantees highest flexibility when adapting to changing applications and measurement jobs. Simply select, change and add the gas sensors required at any time! For this purpose, select from these seven pre-calibrated gas sensors: 1) NO2 sensor The sensor can be changed or upgraded in an additional gas parameter by the user directly on-site without time-consuming test gas adjustment. 2) SO2 sensor 3) COlow sensor 4) NOlow sensor 5) NO sensor 6) CO sensor 7) O2 sensor (standard) Convenient measurement data management with "easyEmission" Data can be read out, easily processed, filed and managed using the "easyEmission" software: Advantages of easyEmission · Readings are shown in table or graph form · User-defined measurement spacing (from one measurement / second to one measurement / hour) · Online measurements via BLUETOOTH® wireless transmission or USB connection · Customer and application-specific measurement protocols · Data structure and measurement information can be transmitted from computer to analyzer · All instrument configurations and settings can be easily carried out with easyEmission · Direct transmission to Excel and pdf formats · Easy implementation of individual formulae for your own calculations · Calculation of fuel factors when using customer-specific fuels testo-340-P02-03 15.02.2013 10:11 Seite 3 testo 340 We measure it. Large selection of flue gas sampling probes Different probe shaft lengths, diameters and temperature ranges ensure high flexibility for all applications. To change, the probe shaft is simply attached to the probe handle and engages. Special flue gas probes for industrial engines are designed for positive pressure at the measurement site, making measurements possible even in the toughest conditions. In addition, modular industrial probes are available for rugged process conditions. Wireless transmission* * Country permits BLUETOOTH® wireless transmission, see Technical Data on page 8. Ready to operate immediately The highly robust fast-action probe coupling for all gas paths eliminates any confusion. The indestructible gas sampling hose cannot be bent, can be extended up to 7.8 m and saves space. The probe can remain positioned in the flue gas during the zeroing phase of the gas sensors. The calibration phase of testo 340 is finished after only 30 seconds. Wireless readout, transmission and printing of readings Wireless connection via Bluetooth® 2.0 to Testo BLUETOOTH® printers and direct communication to notebook/PC over a distance of up to 10 m (free field) are features of the new testo 340 option. Readings and configurations are transmitted wirelessly to your notebook/PC for storage and analysis. Print data is transmitted wirelessly to the printer by infrared interface (visual contact required) or by new BLUETOOTH® wireless transmission. This saves time since the analyzer is ready for use again immediately following data transmission. Measurement gas pump The automatically controlled measurement gas pump built into testo 340 is the ideal solution for typical situations which arise when measuring flue gas such as negative or positive pressure (from -200 to +50 mbar). Pump flow is automatically kept constant. Integrated condensate trap The Testo design eliminates the possibility of condensation accumulating in the actual gas sensor. The testo 340 warns if the condensation trap needs to be emptied. Large selection of probes 18 standard fuels and 10 additional user-defined fuels can be adapted specifically to each application. testo-340-P06-07 15.02.2013 10:14 Seite 6 testo 340 Ordering data Analyzer / Options testo 340 flue gas analyzer, incl. rechargeable battery, calibration protocol and carrying strap, equipped with O2 sensor, integrated flow/differential pressure measurement Part no. 0632 3340 testo 340 must be equipped with a second gas sensor otherwise the analyzer cannot function. Max. 3 additional sensors can be fitted. Option CO sensor, 0 to 10000 ppm, resolution 1 ppm Option COlow sensor, 0 to 500 ppm, resolution 0.1 ppm Option NO sensor, 0 to 4000 ppm, resolution 0.1 ppm Option NOlow sensor, 0 to 300 ppm, resolution 0.1 ppm Option NO2 sensor, 0 to 500 ppm, resolution 0.1 ppm Option: SO2 measurement module, 0 to 5,000 ppm Option: BLUETOOTH® module Option: dilution of all sensors Accessories Part no. Transport case for flue gas analyzer and probes 0516 3400 Mains unit international 100-240 V AC / 6.3 V DC for mains operation or battery charging in instrument, for mains operation or battery charging in instrument 0554 1096 Software "easyEmission", incl. USB connection cable instrument-PC 0554 3334 Multiple license/"easyEmission" software 0554 3338 Testo fast printer IRDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries 0554 0549 BLUETOOTH printer set with wireless BLUETOOTH interface; incl. 1 roll thermal paper, rechargeable battery and mains unit 0554 0553 Spare thermal paper for printer, permanent ink 0554 0568 Spare rechargeable battery with charger 0554 1087 Exchangeable filter NO sensor (1 off), blocks cross-gas SO2 0554 4150 Replacement filter CO sensor (1 pcs.) 0554 4100 Calibration Certificates Part no. ISO calibration certificate/flue gas 0520 0003 ISO calibration certificate velocity, hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s 0520 0004 ISO calibration certificate velocity, hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s 0520 0034 Probes Standard gas sampling probes: Modular flue gas probes, available in 2 lengths, incl. probe stop, NiCr-Ni thermocouple, 2.2 m hose and particle filter Part no. Modular flue gas probe 335 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 500 °C and NO2/SO2 special hose 2.2 m 0600 9766 Modular flue gas probe 700 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 500 °C and NO2/SO2 special hose 2.2 m 0600 9767 Modular flue gas probe 335 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 1000 °C and NO2/SO2 special hose 2.2 m 0600 8764 Modular flue gas probe, 700 mm immersion depth, incl. cone, thermocouple NiCr-Ni Tmax 1000 °C and NO2/SO2 special hose 2.2 m 0600 8765 Modular flue gas probe with pre-filter Ø 14 mm 335 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 1000°C and NO2/SO2 special hose 2.2 m 0600 8766 Modular flue gas probe with pre-filter Ø 14 mm 700 mm immersion depth, incl. cone, thermocouple NiCr-Ni (TI) Tmax 1000°C and NO2/SO2 special hose 2.2 m 0600 8767 testo-340-P06-07 15.02.2013 10:14 Seite 7 testo 340 We measure it. Probes Probe accesories/standard gas sampling probes Part no. Hose extension; 2.8 m; extension cable for probe and analyzer 0554 1202 Probe shaft with pre-filter, length 335 mm, incl. cone, Ø 8 mm, Tmax 1000 °C 0554 8766 Probe shaft with pre-filter, length 700 mm, incl. cone, Ø 8 mm, Tmax 1000 °C 0554 8767 Spare sintered filter, 2 off 0554 3372 Spare dirt filter, modular probe; 10 off 0554 3385 Probe shaft, length probe shaft 700 mm, Tmax probe shaft 500 °C, Ø probe shaft 8 mm 0554 9767 Probe shaft with probe stop, length probe shaft 335 mm, Tmax probe shaft 1000 °C, Ø probe shaft 8 mm 0554 8764 Probe shaft length 700 mm, incl cone, Ø 8 m, Tmax. 1000 °C 0554 8765 Engine probes Part no. Flue gas probe for industrial engines, 335 mm immersion probe incl. cone, integrated condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2/SO2 measurements, length 2.2 m 0600 7560 Flue gas probe for industrial engines with probe shaft prefilter, immersion depth 335 mm, incl. cone, integrated condensate trap and heat protection plate, Tmax 1000 °C, special hose for NO2-/SO2 measurements, length 2.2 m 0600 7561 Thermocouple for exhaust gas temperature measurement, NiCr-Ni, length 400 mm, Tmax. +1000 °C with 2.4 m connection cable and additional temperature protection 0600 8894 Spare particle filter (10 off) for condensate trap in gas sampling hose 0554 3371 Industrial probes Part no. Adapter, non-heated, IP54, gas input G1/4", gas exit M10x1 external thread 0600 7911 Extension pipe to +600 °C, stainless steel 1.4571, 1 m 0600 7802 Extension pipe to +1200 °C, Inconel 625, 1 m 0600 7804 Non-heated sampling pipe to +600 °C, stainless steel 1.4571, 1 m 0600 7801 Non-heated sampling pipe to +1200 °C, Inconel 625, 1 m 0600 7803 Non-heated sampling pipe to +1800 °C, Al-Oxide, 1 m 0600 7805 Pre-filter for dusty flue gases, ceramic, dust load max. 20 g/m³, filter pore size 20 μm, temperature max. 1000 °C pre-filter can only be mounted on extension pipe 0600 7802 or 0600 7804. 0554 0710 Gas sampling hose for precise NO2-/SO2-measurements with built-in condensate trap, length 2.2 m 0554 3352 Thermocouple, NiCr-Ni, -200 to +1200 °C, Inconel 625, length 1.2 m 0430 0065 Thermocouple, NiCr-Ni, -200 to +1200 °C, Inconel 625, length 2.2 m 0430 0066 Mounting flange, stainless steel 1.4571 adjustable quick-action fitting suitable for all sampling/extension pipes 0554 0760 Temperature probes Part no. Mini ambient air probe; for separate ambient air temperature measurement; 0 to +80 °C 0600 3692 Combustion air temperature probe, immersion depth 60 mm 0600 9797 Pitot tubes Part no. Pitot tube, 350 mm long, stainless steel, measures flow velocity 0635 2145 Pitot tube, 1000 mm long, stainless steel, measures flow velocity 0635 2345 Connection hose; silicone; 5 m long; max. load 700 hPa (mbar) 0554 0440 Pitot tube, stainless steel, 750 mm long, measures flow velocity with temperature, 3x hoses (5 m long) and heat protection plate 0635 2042 testo-340-P08-09 15.02.2013 10:16 Seite 8 testo 340 We measure it. Technical data O2 measurement 0 to 25 Vol. % ±0.2 Vol. % 0.01 Vol. % Adjustment time t90 〈 20 sec CO measurement (H2 compensated) 0 to 10.000 ppm ±10 ppm or ±10% of mv (0 to 200 ppm) ±20 ppm or ±5% of mv (201 to 2.000 ppm) ±10% of mv (2.001 to 10.000 ppm) 1 ppm 〈 40 sec COlow measurement (H2 compensated) 0 to 500 ppm ±2 ppm (0 to 39.9 ppm) ±5% of mv (remaining range)X 0.1 ppm 〈 40 sec Meas. range Accuracy ±1 digit Resolution X data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K. NO measurement 0 to 4.000 ppm ±5 ppm (0 to 99 ppm) ±5% of mv (100 to 1.999 ppm) ±10% of mv (2.000 to 4.000 ppm) 1 ppm 〈 30 sec NOlow measurement 0 to 300 ppm ±2 ppm (0 to 39.9 ppm) ±5% of mv (remaining range) 0.1 ppm 〈 30 sec NO2 measurement* 0 to 500 ppm ±10 ppm (0 to 199 ppm) ±5% of mv (remaining range) 0.1 ppm 〈 40 sec SO2 measurement* 0 to 5.000 ppm ±10 ppm (0 to 99 ppm) ±10% of mv (remaining range) 1 ppm 〈 40 sec Temperature meas. -40 to +1.200 °C ±0.5 °C (0 to +99 °C) ±0.5 % of mv (remaining range) 0.1 °C Draught measurement -40 to +40 hPa ±0.03 hPa (-2.99 to +2.99 hPa) ±1.5 % of mv (remaining range) 0.01 hPa Differential pressure measurement -200 to 200 hPa ±0.5 hPa (-49.9 to 49.9 hPa) ±1.5 % of mv (remaining range) 0.1 hPa Absolute pressure measurement 600 to +1.150 hPa ±10 hPa 1 hPa Probe type Type K (NiCr-Ni) Derived parameters Efficiency 0 to 120 % 0.1 % Flue gas loss 0 to 99.9 % 0.1 % Exhaust gas dewpoint 0 to 99.9 °C CO2 measurement 0 to CO2 max. 0.1 °C ±0.2 Vol. % 0.1 Vol. % 〈 40 sec (Calculated from O2) *To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded. Country permits BLUETOOTH® wireless transmission for testo 340 The BLUETOOTH® radio module used by Testo is permitted for the following countries and may only be used in those countries, i.e. the BLUETOOTH® wireless transmission may not be used in any other country! Europe including all EU member states Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden and Turkey European countries (EFTA) Iceland, Liechtenstein, Norway, Switzerland Non-European countries Canada, USA, Japan, Ukraine, Australia, Columbia, El Salvador, Mexico, Venezuela testo-340-P08-09 15.02.2013 10:16 Seite 9 testo 340 We measure it. Technical data Measuring range extension Single dilution, factor 5 (standard) Meas. range Accuracy Resolution CO measurement (H2 compensated) 700 ppm to 50.000 ppm ±10 % of mv (additional error) 1 ppm COlow measurement (H2 compensated) 300 ppm to 2.500 ppm ±10 % of mv (additional error) 0.1 ppm NO measurement 500 ppm to 20.000 ppm ±10 % of mv (additional error) 1 ppm NOlow measurement 150 ppm to 1.500 ppm ±10 % of mv (additional error) 0,1 ppm SO2 measurement 500 ppm to 25.000 ppm ±10 % of mv (additional error) 1 ppm Dilution of all sensors, factor 2 (option, Part no. 0440 3350) O2 measurement When measuring range extension switched on, over all sensors: ±1 Vol.% additional error 0 to 25 Vol.% (0 to 4.99 Vol.%) ±0.5 Vol.% additional error (5 to 25 Vol.%) 0.01 Vol.% CO measurement (H2 compensated) 700 ppm to 20.000 ppm ±10 % of mv (additional error) 1 ppm COlow measurement (H2 compensated) 300 ppm to 1.000 ppm ±10 % of mv (additional error) 0.1 ppm NO measurement 500 ppm to 8.000 ppm ±10 % of mv (additional error) 1 ppm NOlow measurement 150 ppm to 600 ppm ±10 % of mv (additional error) 0.1 ppm NO2 measurement 200 ppm to 1.000 ppm ±10 % of mv (additional error) 0.1 ppm SO2 measurement 500 ppm to 10.000 ppm ±10 % of mv (additional error) 1 ppm General technical data Memory Maximum Per folder Per site User-defined fuels Regulated diaphragm pump Pump flow Hose length 100 folders Max. 10 sites Max. 200 logs The max. number of logs is determined by the number of folders or sites 10 user-defined fuels incl. test gas as fuel Display Graphic display 160 x 240 pixels Power supply Battery block 3.7 V / 2.4 Ah Mains unit 6.3 V / 2 A Housing material TPE PC Protection class IP40 Warranty Analyzer Rech. batt. Sensors Max. pos. press./flue gas Max. neg. press./flue gas 0.6 l/min (regulated) max. 7.8 m (corresponds to two probe hose extensions) +50 mbar -200 mbar Weight 960 g Dimensions 283 x 103 x 65 mm Storage temp. -20 to +50 °C Oper. temp. -5 to +50 °C 2 years (excluding working parts, e.g. sensors, sensor replacement filter) 1 year CO, NO, COlow, NOlow, NO2, SO2: 1 year O2: 1.5 years OMNI Novel Concept Emergent PENTA Thermal Mass Gas Flow Meter OMNI Telemetry Co. 5 Ellen Street Mississauga-L5m 1R8 Ontario, Canada Telephone: +1 416 855 1942 Fax: +1 416 907 9712 Email: info@omnitm.ca, Website: www.omnitm.ca Datasheet OGF5400_PENTA Applications Characteristics For application in industrial and commercial air/gas flow metering Compact water proof and explosion proof both types are available Preferred areas of use are: Universal 90-260 V AC or 24 V DC input power, solar power (optional) Compressed air Combustion air Natural gas Aeration air Large graphic TFT LCD touch screen Menu driven parameter display, setup and configuration with win8 launcher Digester/Bio-gas Programmable parameters with password protection Vent line/flare headers Modbus RS485 communication Other specific gases Data logging Preferred customers: Industrial sector, gas distribution and supply organizations Bulk customers, housing societies Sub metering Control line losses and leakage in supply system 0 to 70 C ambient operating temperature range 0 to 180 C process temperature range Process pressure up to 16 Bar 2-10 V DC and pulse output for flow On site setup as per line size and other parameters From 1” to 16” line sizes measurement Stainless steel probe and shaft and fittings Direct mass flow measurement of air and gases Accuracy: 1% High turndown: 100:1 Excellent low flow sensitivity On site setup as per line size and type of gas Temperature pressure compensation TFT color touch screen Win8 launcher Very low pressure drop Line size from 1” to 16” OGF5400_PENTA Page 2 of 9 Datasheet OGF5400_PENTA Features Specifications OGF5400_PENTA is an intelligent solution for accurate consumption measurement for compressed air and gases. An affordable flow meter OGF5400_PENTA is work according to the approved calorimetric measuring principle. In this process a heated sensor is cooled down by the gas circulating around it. The flow-dependent cooling-down is used as a measuring effect while the degree of cooling-down is directly depending on the passing air resp. gas mass. Therefore, an additional pressure and temperature compensation is not necessary. Range: 0~63m/s Accuracy: ±1% of reading ±0.5% of F.S Turndown: 100:1 Response time: 3 sec., adjustable through damping coefficient Operating temperatures (Ambient): -10~70°C Media temperature: 0~180°C, 0~250°C (optional) Operating pressure: up to 16 Bar Analog output: 2-10 V DC output for flow rate Communication: Modbus protocol RS485 Pulse output: 1 pulse of unit value, Width 50 ms Material: Sensor: 316L and Alloy C-276 Sensor support: 304 and 316L Ø19mm IP protection: IP67 Humidity: 0~100% RH Display: Graphic TFT color touch screen LCD for parameters local monitoring, data logging, setup and configuration Power supply: SMPS 110-250 V AC/ 24 V DC Due to its compact design it is possible to monitor all compressed air systems from the compressor to the smallest compressed air line (25mm to 50mm) with the new affordable flow meter OGF5400-50. New flow meters OGF5400_PENTA are available or larger pipe diameters from DN 50 to DN 400. Apart from compressed air also other gases like e. g. nitrogen, oxygen and CO2 can be measured. The built-in gas conversion coefficient list can be used to correct when the flow meters used to measure the non-air gases. The mounting for the meters with the DN15-DN50 is pipe type, and it is insertion type for the upstream pipe when the DN is above 50mm. The correction feature allows OGF5400_PENTA accuracy to installer no effect when suppress the range, this can help customers to reduce the stock amount and change the range in field. Volumetric flow ranges Line DN m3/h 1” 25 90 2” 50 315 3” 75 765 4” 100 1,125 5” 125 1,935 6” 150 2,925 8” 200 4,410 10” 250 6,750 12” 300 9,900 16” 400 16,137 The intelligent OGF5400_PENTA use advanced ARM MCU and TFT color touch screen display multiple parameters and menu driven setup based on Win8 launcher. Including mass flow rate and totalized mass in your choice of engineering units, and features an intuitive and easy-to-use menu for configuration and diagnostics. Changing ranges, fluids, alarms, outputs, totalizes and engineering units can be done from local touch screen, or PC, or remotely with telemetry unit option. The unit of flow rate can set to any engineering unit. Mentioned flow rates are standard flows at 20 °C and 1 Bar. Power saving mode: For reducing power consumption and enhancing touch screen life, backlit of LCD will turned off after 10-minutes. For large diameter pipes applications customized OGF5400_PENTA gas flow meters are available on customer request. OGF5400_PENTA The table above shows flow ranges up to 400 mm pipe diameter at standard conditions in air. At other standard conditions and in other gases flow ranges are different. Page 3 of 9 Datasheet OGF5400_PENTA Ordering information OGF5400_50F OGF5400_50F: Low cost general purpose gas flow metering unit complete with mounting flanges for line size up to 2”. OGF5400_PENTA_XXIEXL2AR XX: Insertion type from 2” to 12” with DN suffix 50 to 300 I: Insertion type F: Flange type EX: IP67 Explosion Proof housing L2: High temperature version up to 250 C. A: Power supply (SMPS) 90-250 V AC D: Aux. power supply 24 V DC R: Remote telemetry Accessories Aux. power supply: 24 V DC Solar charging: Solar/ Aux. charging unit with backup battery Communication module: Modbus RS485 Remote telemetry: GSM/ GPRS based remote monitoring and setup Disclaimer The information contained in this document is subject to change without notice. OMNI Telemetry Co. makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. ©2008 OMNI Telemetry Co. All rights reserved. OGF5400_PENTA Page 9 of 9 OMNI Novel Concept Emergent SMART Steam Flow Computers OMNI Telemetry Co. 5 Ellen Street Mississauga-L5m 1R8 Ontario, Canada Telephone: +1 416 855 1942 Fax: +1 416 907 9712 Email: info@omnitm.ca, Website: www.omnitm.ca Datasheet FCU5400_SMART Applications Characteristics For application in the process engineering, suit for liquids, vapor, or gases Compact water proof and explosion proof both types are available Preferred areas of use are: Universal 90-260 V AC or 24 V DC input power, solar power (optional) Large graphic TFT LCD touch screen Process engineering Menu driven parameter display, setup and configuration with win8 launcher Chemical industry Textiles Power plants Programmable parameters with password protection Compressor stations Modbus RS485 communication Pharmaceuticals Data logging Food & beverage 0 to 70 C ambient operating temperature range Sugar 2-10 V DC and pulse output for flow On site setup as per line size and other parameters Remote telemetry (optional) • • • • • Flow rate indicator & totalizer Batch controller Flow rate controller Multiple inputs Computer unit for multi variable FCU5400_SMART • On site setup as per line size • • • • Temperature compensation Pressure compensation TFT color touch screen Win8 launcher Page 2 of 9 Datasheet FCU5400_SMART Features Specifications Feature Rich and Flexible General The SMART FCU5400 process indicator and controller boasts specifications and functionality that clearly makes it one of the most advanced process meters available. Its TFT touch screen, advanced math functions, function keys, and optional modules are only a few of the features you will find on the SMART FCU5400. Display: High contrast TFT color touch screen Flow rate: 12 digits, Totalizing: 12 digits Display update rate: 100 ms Panel: IP65 water proof Password: Password restrict modification of programmed settings EEPROM: Data retention up to 40 years Power options: 90-260 V AC 50/60 HZ, 12 watts or 24 V DC Environmental: Operating temperature range: -10 to 65 C. Storage temperature range: -40 to 85 C. Relative humidity: 0 to 90% non-condensing Connections: Removable screw terminal blocks accept 12 to 22 AWG wire Mounting: Four panel mounting bracket assemblies for wall mounting Warranty: 1 year parts & labor Precise, Accurate, and more informative SMART FCU5400 large TFT LCD display will provide you with a highly accurate and precise view of all parameters. It 13-bit A/D is accurate to 0.05% FS 1 count. Configurable The main display can be programmed to indicate m3/h, TPH, Kg/h, and auto decimal converter. Configuration and setup is by menu driven parameter. Environmentally tough Extra bright graphic LCD, readable in open environment also. Water proof IP65 housing. Easy to use The user friendly manue based on win-8 launcher makes the SMART FCU5400 easy to setup & program. No jumpers to set, or potentiometer to adjust. All setup and programming is done via the front touch screen. A unique password protection is help to maintain the reliability of the programming at every level. Customized options Due to boot-rom firmware up gradation, the SMART FCU5400 can be programed as: • Flow rate indicator & totalizer • Batch controller • Flow rate controller • Multiple inputs • Computer unit for multi variable Process input Input: 0-20 mA, 4-20mA, 0-10 V DC, 2-10 V DC Math function: Linear, square root, or programmable exponent, multipoint linearization for gas flow Programmable exponent: 0.01 to 1.99 Low range cutoff: Programmable low range Decimal point: Auto decimal up to 3 digits Calibration range: Minimum span: 0.15 mA or 0.10 V Input Impedance: Voltage: 1 M , Current: 5 Analog output Output source: Process variable Scaling range: 4.0 to 20.0 mA for any display range Calibration: Factory calibrated Accuracy: 0.1% FS 0.004 mA Serial Communication Address: 1-32 Baud rate: 9600 Data: 8 bit (1 start bit, 1 stop bit), parity none Power saving mode: For reducing power consumption and enhancing touch screen life, backlit of LCD will turned off after 10minutes. FCU5400_SMART Page 3 of 9 Datasheet FCU5400_SMART Ordering information FCU5400_SMART_XXXTPF XXX: Line size, DN suffix 50 to 300 T: With temperature sensor P: Pressure transmitter F: DP type flow transmitter, refer to our OSF5400 transmitter range, otherwise please specify Accessories Aux. power supply: 24 V DC Solar charging: Solar/ Aux. charging unit with backup battery Communication module: Modbus RS485 Remote telemetry: GSM/ GPRS based remote monitoring and setup Disclaimer The information contained in this document is subject to change without notice. OMNI Telemetry Co. makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. ©2008 OMNI Telemetry Co. All rights reserved. FCU5400_SMART Page 9 of 9 SDS M1200-08 VORTEX FLOWMETER MODEL EF73 RELIABLE FLOW MEASURING SYSTEM FOR STEAM, AIR AND WATER Features High-performance vortex flowmeter with robust sensor for highly accurate volume or mass flow measurements of saturated and superheated steam, air and water. 1. DSC (Differential Switched Capacitance) sensor offers a wide measuring range, with a high resistance to thermal shock, vibration and water hammer. 2. Integrated flow computer calculates mass flow from measured volume flow and temperature variables. 3. Capable of simultaneous pulse (interval) and analog (instantaneous) output. 4. Requires no maintenance, has no moving parts, and experiences no zero point drift. 5. Low pressure drop through body. Specifications Meter Body / Sensor Model 5.5 Between Flanges (Flangeless) Flanged 15, 25, 40, 50, 80, 15, 25, 40, 50, 80, 100, 100, 150 150, 200, 250, 300 Connection Compatibilities See details in the Dimensions section Operating Pressure Range (MPaG) 0 – 4.96 (See the table to the right for details) -2001) – +400 (See the table to the right for details) Steam, Air, Water Temperature Range (°C) Applicable Fluids2) 3) Volume Flow Mass Flow Repeatability Gas/Steam: ± 1% of reading (Re > 20 000), ± 1% of full scale (Re: 4 000 – 20 000) Liquid: ± 0.75% of reading (Re > 20 000) ± 0.75% of full scale (Re: 4 000 – 20 000) Saturated ± 2% of reading4) (Re > 20 000) Steam: ± 2% of full scale4) (Re: 4 000 – 20 000) ASME 300 4.5 4.0 DIN PN 40 3.5 3.0 DIN PN 25 2.5 JIS 20K 2.0 1.6 1.5 ASME 150 DIN PN 16 1.0 DIN PN 10, JIS 10K 0.5 0 -200 Mounting Position At least 1G in all directions (10 – 500 Hz) No restriction with regards to meter accuracy 1) Subject to the limitations of fluid freezing point 2) For superheated steam and air, an external pressure sensor and flow computer may be required if inlet pressure fluctuates 3) Do not use for toxic, flammable or otherwise hazardous fluids 4) ±2.3% for remote version Transmitter Explosion Class Non-explosion proof Ambient Temperature Ingress Resistance Compact Type: -40 – +70 °C Remote Type: -40 – +80 °C Power Source 12 – 36 V DC (24 V DC recommended) Power Consumption Power Line Connection 1.2 W DC (including sensor) G(PF)a/B 2-wire System (2-conductor, shielded, at least 1.25 mm2) Field Wiring Load Line Resistance 100 Maximum 550Ω at 24 V To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. 200 300 400 Temperature (°C) 1 MPa = 10.197 kg/cm2 Reynolds Number (Re) Calculation: dxV d = pipe diameter V = velocity Re= ——— ν ν = viscosity Transmitter Terminals A + 1 2 A: Power supply/ current output B: Optional frequency output C: Ground terminal (for remote version) B + 3 4 C IP 67 (NEMA 4X) Frequency (pulse) output: Open collector pulse (passive) Analog output: 4 – 20 mA DC Output 0 -100 Within 0.25% of reading Vibration Resistance CAUTION Maximum Operating Pressure 5.0 4.96 Pressure (MPaG) Size (mm) Accuracy Pressure/Temperature Operating Range EF73 Connection Display I 48.25 kg/h 3702.6 t Esc - + E Sample display Specifications No. Description q Meter Body w Bluff Body DSC Sensor (wetted parts) e DSC Sensor (non-wetted parts) r Pipe Stand t Transmitter Housing y Gasket u Nameplate i Mounting Kit** o Remote Transmitter Mount*** !0 Connecting Cable (30 m)*** Material* Cast Stainless Steel Cast Stainless Steel Stainless Steel (DIN 1.4435) Stainless Steel (DIN 1.4301) Cast Stainless Steel Die-cast Aluminum Graphite — — Die-cast Aluminum — JIS* SCS16A SCS16A SUS316L SUS304 SCS13A — — — — — — ASTM/AISI A351 Gr. CF3M A351 Gr. CF3M AISI316L* AISI304* A351 Gr. CF8 — — — — — — * Equivalent ** Flangeless model only, to ensure concentric installation; includes centering rings, threaded bolts, nuts, washers and flange gaskets *** Remote version only, see next page Piping Installation Required Length of Straight Piping Element No Flow Conditioner Mounting Position A With Flow Conditioner (Rectifier) - Esc + E Flow Conditioner B Control Valve 50D A - Esc + E 5D 5D B 8D A + 1. High-temperature Fluids For high-temperature fluids (steam, condensate), positions A, B or C should be selected to protect the transmitter from heat. 5D B Esc - E C - Esc + E Flow Conditioner Concentric Reducer (Convergent-Pipe) 15D A Esc - + E 2D 5D B 8D A 5D B Esc - + E Flow Conditioner Concentric Diffuser (Expansion-Pipe) 5D B Esc - + E 2D+5h 8D A 5D B Esc - + E Flow Conditioner Eccentric Reducer (Convergent-Pipe) 25D A 5D B Esc - + E 5D 8D A 5D B Esc - + E Flow Conditioner One 90 Elbow or T-piece 20D A 5D B Esc - + E 2D 8D A 5D B Esc - + E Flow Conditioner Two 90 Elbows (2-Dimensional) 25D A 5D B Esc - + E 5D 8D A 5D B Esc - + E Flow Conditioner Two 90 Elbows (3-Dimensional) 40D A 5D B Esc - + E 5D 8D A 5D B Esc - + - D Esc + E 2. Water To make sure the pipes are completely flooded with Water, position C is recommended. Pressure Measurement Points h 18D A There is no restriction for mounting position (A – D) in regards to meter accuracy. However, special care is recommended for the following flow mediums: E If a pressure measuring point is installed after the device, ensure that there is a large enough distance between the device and the measuring point so that there are no negative effects on vortex formation in the sensor. PT Downstream 3 – 5D c + E D = Nominal Diameter Pipeline Insulation The pipe stand serves as a radiator and protects the electronics from overheating. Therefore, ensure that sufficient surface area remains exposed. Be sure not to insulate passed the level marked “max.” on the pipe stand. - Esc + E Ensuring Steam Quality Wet steam has a higher density than saturated steam. Since the flowmeter mass flow calculations are based on saturated steam density, the actual mass flow of wet steam will be higher than shown by the flowmeter. The upstream installation of a separator (DC3S) is suggested to ensure steam quality and flowmeter accuracy. The proper separation and drainage of condensate is a recommended practice for all steam applications. 50D Combination Pipe (Elbows & Eccentric Reducer, etc.) Flow Conditioner 50D A Esc - + E 5D B 5D 8D A Esc - + E 5D B Wet Steam Saturated Steam c + E A = Upstream, B = Downstream, D = Nominal Diameter DC3S separator with built-in steam trap SDS M1200-08 Dimensions EF73 ¡EF73 Remote Version Weight** (kg) 17 276 246 3.0 28 286 256 3.2 82 42 294 264 3.8 92 54 301 271 4.1 80 127 80 315 285 5.5 100 157 105 328 298 6.5 150 216 157 354 324 9.0 15 45 25 64 40 65 EF73 Size 115 φ85 Remote 15 277 247 5.5 25 284 254 7.5 292 262 11 50 299 269 13 80 312 282 21 324 294 28 348 318 52 377 347 65 (77) 40 L 250 300 300 250 380 380 404 374 93 (110) 300 450 450 427 397 144 (163) TEMP 2 TEMP 3 5 6 7 8 RD TEMP 1 4 BU – 5 VA 3 PK + 5 VA 2 GY 1 WT GROUND Remote Transmitter to Sensor Wiring YL 211 DIFF – Pipe Mounted* 6 7 TEMP 2 RD BU 5 TEMP 1 8 TEMP 3 PK 4 – 5 VA GY 3 + 5 VA YL 2 GROUND GN 1 DIFF – * Requires optional parts DIFF + Remote transmitter weight: 3.5 kg WT 100 123 BN 100 133 348 221 250 200 Other standards available, but weight may vary * Weight is for compact version ( ) ASME Class 300 RF 20 – 80 mm pipe Remote Transmitter Wall Mounted 200 300RF Weight* (kg) Compact 200 L H1 ASME Class 150RF H1 H1 149 (mm) L 150 154 141 Flanged Remote Version 100 ¡EF73 65 GN Flanged Compact Version L * Compatible with ASME Class 150, 300, JIS 10K/20K, and DIN 2501 PN10/16, 25/40 flange standards ** Weight is for compact version ¡EF73 154 141 Remote φd 50 H1 d D L Compact φD Size 115 φ85 H1 149 (mm) H1 DIFF + 154 141 Flangeless* BN Flangeless Compact Version Options q Pipe Mounting Kit w Sunshade for Transmitter e Flow Conditioner Suitable for 20 – 80 mm pipe. (Includes bracket, threaded bolts and nuts.) SDS M1200-08 Flow Rate for Saturated Steam ¡EF73 Flangeless (Unit: kg/h) Size (mm) Pressure (MPaG) Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. 0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.2 1.5 2.0 2.5 3.0 4.4 5.0 6.0 6.9 7.6 8.3 8.9 9.5 10 11 11 12 14 15 17 19 30 40 58 76 94 112 130 147 165 182 199 234 286 373 460 549 13 14 17 20 22 24 25 27 28 30 31 34 37 42 47 51 140 183 267 350 432 512 593 673 752 832 911 1069 1306 1702 2101 2505 33 38 45 52 58 63 67 72 76 80 83 90 100 114 126 137 325 424 620 811 1000 1187 1373 1558 1743 1927 2110 2476 3025 3942 4866 5801 53 61 73 84 93 101 109 116 123 129 135 146 162 184 205 224 527 689 1006 1316 1623 1927 2229 2529 2828 3127 3424 4018 4909 6397 7897 9413 119 136 165 188 209 228 245 261 276 290 303 328 363 414 460 502 1187 1551 2263 2962 3652 4336 5015 5691 6364 7035 7705 9042 11046 14394 17768 21180 203 232 280 320 356 387 417 444 469 493 516 559 618 706 784 856 2023 2643 3856 5047 6223 7388 8545 9697 10843 11987 13128 15406 18820 24525 30274 36087 ¡EF73 15 25 40 50 80 100 150 Min. 454 4531 111.6 519 5919 120.4 627 8636 133.7 717 11303 143.7 796 13936 151.9 867 16545 158.9 932 19136 165.0 993 21714 170.5 1050 24282 175.4 1104 26843 179.9 1156 29398 184.1 1252 34499 191.6 1384 42143 201.4 1579 54918 214.9 1755 67791 226.1 1916 80810 235.7 1 MPa = 10.197 kg/cm2 Flanged 15 Size (mm) Pressure Min. Max. (MPaG) 21 3.1 0.05 28 3.5 0.1 41 4.3 0.2 54 4.9 0.3 66 5.4 0.4 79 5.9 0.5 91 6.3 0.6 103 6.7 0.7 116 7.1 0.8 128 7.5 0.9 140 7.8 1.0 164 8.5 1.2 201 9.4 1.5 262 11 2.0 323 12 2.5 386 13 3.0 Temp (°C) Max. (Unit: kg/h) 25 40 50 80 100 150 200 250 300 Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Temp (°C) 9.4 11 13 15 17 18 20 21 22 23 24 26 29 33 37 40 108 142 207 271 334 397 459 521 583 645 706 829 1012 1319 1629 1942 27 31 37 43 47 52 56 59 63 66 69 74 82 94 104 114 267 349 510 667 823 977 1130 1282 1434 1585 1736 2038 2489 3244 4005 4774 45 52 62 71 79 86 92 98 104 109 114 124 137 156 173 189 446 583 850 1113 1372 1629 1885 2139 2392 2644 2896 3398 4151 5410 6678 7961 101 115 139 159 176 192 207 220 233 245 256 277 306 350 388 424 1001 1308 1909 2498 3080 3657 4230 4800 5368 5934 6499 7626 9316 12140 14986 17864 174 199 240 275 305 332 357 381 403 423 443 480 530 605 672 734 1735 2266 3307 4328 5336 6335 7328 8315 9298 10279 11257 13211 16138 21030 25960 30945 396 452 546 624 693 755 812 865 915 962 1007 1091 1205 1376 1529 1669 3947 5156 7523 9846 12140 14412 16669 18915 21152 23383 25609 30053 36712 47839 59054 70394 759 867 1047 1198 1330 1450 1559 1661 1756 1846 1932 2093 2313 2641 2934 3203 7577 9897 14442 18901 23304 27667 32000 36311 40605 44887 49160 57690 70473 91835 113363 135132 1196 1367 1651 1889 2097 2285 2457 2618 2768 2910 3046 3299 3646 4162 4625 5049 11945 15603 22767 29796 36737 43614 50445 57241 64010 70761 77497 90944 111095 144769 178705 213023 1715 1960 2368 2709 3008 3277 3524 3754 3970 4174 4368 4732 5230 5970 6633 7242 17133 22380 32655 42738 52694 62558 72356 82103 91813 101496 111158 130446 159349 207649 256326 305549 111.6 120.4 133.7 143.7 151.9 158.9 165.0 170.5 175.4 179.9 184.1 191.6 201.4 214.9 226.1 235.7 1 MPa = 10.197 kg/cm2 Flow Rate for Air and Water (Unit: m3/h) Model Fluid Size (mm) 15 25 40 50 80 100 150 200 250 300 EF73 Flangeless Air (0 °C, atmospheric pressure) Water (20 °C) Min. Max. Min. Max. 6.9 0.19 35 4.1 19 0.41 161 12 44 1.11 374 31 72 1.80 606 50 163 4.04 1365 113 279 6.88 2326 191 625 15.4 5210 428 – – – – – – – – – – – – EF73 Flanged Air (0 °C, atmospheric pressure) Water (20 °C) Min. Max. Min. Max. 4.9 0.16 24 2.9 15 0.32 125 8.9 36 0.91 307 26 61 1.52 513 43 138 3.41 1151 95 239 5.90 1995 164 544 13.5 4538 373 1045 25.8 8712 715 40.6 1648 13735 1127 2364 58.3 19700 1617 SDS M1200-08 Rev. 5/2012 Products for intended use only. Specifications subject to change without notice.
© Copyright 2024