J Jones Trading As Specialist in all types of locks , safes & vaults opening, repairing, supply & fitting. Domestic, commercial, Emergency service Private Address 35 Nursery Road Hoddesdon Hertfordshire EN11 9LB La Gard Basic Series Instructions Factory set combination 1-2-3-4-5-6 Wrong Try Penalty & Signals Four consecutive invalid combinations initiates a five minute delay period. * Double signal - two LED flashes and two beeps - indicates entry is valid or accepted. * Triple signal - three LED flashes and three beeps - indicates invalid or not accepted. Opening the lock Enter valid six digit combination, two LED flashes and two beeps, Then turn the dial right untill it stops Changing The Combination Always perform this operation with th door open & the lock locked. 1) Enter "zero" six times. 2) Enter your existing six digit combination one time 3) Enter your new six digit combination two times 4) If a mistake is made wait thirty seconds and repeat steps 1 - 3 5) Test lock operation several times before closing the door