Straps & Ties Z Clips Z clips secure 2x4 flat blocking between joists or trusses to support sheathing. MATERIAL: See table FINISH: Galvanized INSTALLATION: • Use all specified fasteners; see General Notes. • Z clips do not provide lateral stability. Do not walk on stiffeners or apply load until diaphragm is installed and nailed to stiffeners. CODES: See page 12 for Code Reference Key Chart. Model No. Ga Z2 Z4 Z28 Z38 Z44 20 12 28 28 12 Dimensions W 2 5⁄16 1 1⁄2 2 5⁄16 2 5⁄16 2 1⁄2 H 1 1⁄2 3 1⁄2 1 1⁄2 2 1⁄2 3 1⁄2 B 1 3⁄8 2 1⁄8 1 3⁄8 1 3⁄8 2 TF 1 3⁄8 1 3⁄4 1 3⁄8 1 3⁄8 1 3⁄8 1.Z28 and Z38 do not have nail holes. Fastener quantity and type shall be per Designer. 2.Allowable loads may not be increased. Fasteners1 (Total) 4-10dx1 1⁄2 2-16d 10dx1 1⁄21 10dx1 1⁄21 4-16d Allowable Download (100) 470 465 — — 865 170 I14, L18, F13 Typical Z2 Installation 3.Z4 loads apply with a nail into the top and a nail into the seat. 4.NAILS: 16d = 0.162" dia. x 3 1⁄2" long, 10dx1 1⁄2 = 0.148" dia. x 1 1⁄2" long. See pages 22-23 for other nail sizes and information. These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details. Versatile angle gussets and heavy angles promote standardization and construction economy, and are compatible with Simpson Strong-Tie® structural hardware. FINISH: 7 ga Models–Galvanized; 3 ga Models–Simpson Strong-Tie® gray paint. May be ordered HDG. Contact Simpson Strong-Tie. OPTIONS: Gussets may be added to HL models when L ≥ 5" (specify G after model number, as in HL46G). CODES: See page 12 for Code Reference Key Chart. Uplift Optional Gusset HL55 (Others similar) L18 I14, L18, F13 HL Heavy Angles and Gussets HL53 Z4 Code Ref. Typical HL55 Installation Model Ga No. W1 &W2 HL33 7 3 1⁄4 HL35 7 3 1⁄4 HL37 7 3 1⁄4 HL53 7 5 3⁄4 HL55 7 5 3⁄4 HL57 7 5 3⁄4 HL43 3 4 1⁄4 HL46 3 4 1⁄4 HL49 3 4 1⁄4 HL73 3 7 1⁄4 HL76 3 7 1⁄4 HL79 3 7 1⁄4 1. Allowable loads have been Allowable 60% for wind or Loads Code increased earthquake loading with no Ref. further increase allowed; reduce L D1 D2 D3 D4 Qty Dia Uplift F1 where other loads govern. Bolts (Total) Dimensions 2 1⁄2 5 7 1⁄2 2 1⁄2 5 7 1⁄2 3 6 9 3 6 9 1 1⁄4 1 1⁄4 1 1⁄4 1 1⁄4 1 1⁄4 1 1⁄4 1 1⁄2 1 1⁄2 1 1⁄2 1 1⁄2 1 1⁄2 1 1⁄2 — 2 1⁄2 2 1⁄2 — 2 1⁄2 2 1⁄2 — 3 3 — 3 3 2 2 2 2 2 2 2 3⁄4 2 3⁄4 2 3⁄4 2 3⁄4 2 3⁄4 2 3⁄4 — — — 2 1⁄2 2 1⁄2 2 1⁄2 — — — 3 3 3 2 4 6 4 8 12 2 4 6 4 8 12 ⁄2 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 1 ⁄2 910 910 910 910 910 910 1555 1555 1555 1555 2115 2115 1 1 ⁄4 ⁄4 3 ⁄4 3 ⁄4 3 ⁄4 3 ⁄4 3 3 2. Use 0.85 times table load 1580 for Hem Fir. 3. Parts should be centered on 1580 the face of the member to 1580 which they are attached. 4. Wood members for the ‘3’ 1580 and ‘5’ series must have a 1580 minimum width and thickness of 3 1⁄2" for table loads to apply. 1580 5. Wood members for the ‘4’ and 170 ‘7’ series must have a minimum 1580 width and thickness of 5 1⁄8" 2025 for table loads to apply. 6. Parts must be used in pairs. 2025 7. Lag bolts of equal diameter 2025 (minimum 5" long) may be substituted for machine bolts 3800 into beam with no reduction 3800 in load. L–Staggered nail pattern reduces the possibility for splitting. LS–Field-adjustable 0° to 135° angles.The GA Gusset Angles’ embossed bend section provides added strength. MATERIAL: L–16 gauge; GA and LS–18 gauge FINISH: Galvanized. Some products available in stainless steel or ZMAX® coating; see Corrosion Information, pages 13-15. INSTALLATION: • Use all specified fasteners; see General Notes. • LS–field skewable; bend one time only. • Joist must be constrained against rotation (for example, with solid blocking) when using a single LS per connection. • Nail the L angle’s wider leg into the joist to ensure table loads and allow correct nailing. CODES: See page 12 for Code Reference Key Chart. L Model Fasteners No. GA1 GA2 L30 L50 L70 L90 LS30 LS50 LS70 LS90 208 4-10dx1 1⁄2 6-10dx1 1⁄2 4-10dx1 1⁄2 6-10dx1 1⁄2 8-10dx1 1⁄2 10-10dx1 1⁄2 6-10dx1 1⁄2 6-10d 8-10dx1 1⁄2 8-10d 10-10dx1 1⁄2 10-10d 12-10dx1 1⁄2 12-10d Df/SP Allowable Loads Wind/ Floor Snow Roof Seismic (100) (115) (125) (160) 235 270 290 330 355 405 435 550 245 250 250 250 365 415 445 555 485 550 595 740 610 690 740 925 325 325 325 325 355 395 395 395 475 540 565 565 475 540 585 730 595 640 640 640 595 675 730 915 715 810 845 845 715 810 875 1040 SPF/HF Allowable Loads Wind/ Floor Snow Roof Seismic (100) (115) (125) (160) 200 230 250 285 305 350 375 475 210 215 215 215 315 355 385 475 415 475 510 635 525 595 635 795 280 280 280 280 305 340 340 340 410 465 485 485 410 465 505 630 510 550 550 550 510 580 630 785 615 695 725 725 615 695 755 895 Code Ref. These products are approved for installation with the Strong-Drive ® SD Connector screw. See page 27 for more information. Adjustable from 0° to 135° Bend one time only. IP1, L5, L18, F13 IP1, L5, F13 Shipped at 45° LS Top View IP1, L5, L18, F13 GA1 LS L90 These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details. Typical GA Installation Load Direction See Installation Notes 1. L angles–loads are for condition F1 or F2; LS angles–loads are for condition F1 only. 2.GA1 and GA2 angles table loads are F1 – loads for F2 are 235 lbs. and 355 lbs. (100) and 290 lbs. and 435 lbs. (125), respectively. 3.Roof loads are 125% of floor loads unless limited by other criteria. Typical L50 Installation 4.Connectors are required on both sides to achieve F 2 loads in both directions. 5.GA angles may be installed with 10d nails. 6.NAILS: 10d = 0.148" dia. x 3" long, 10dx1 1⁄2 = 0.148" dia. x 1 1⁄2" long. See pages 22-23 for other nail sizes and information. Load Direction Typical S70 Installation C-C-2015 © 2015 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/14 Straps & Ties L/LS/GA Reinforcing and Skewable Angles
© Copyright 2024