TM VPAP IV and VPAP TM IV ST Product Training VPAP is a trademark of ResMed Ltd and registered in U.S. Patent and Trademark Office. 1 VPAP IV/ST June 08 © ResMed Global leaders in sleep and respiratory medicine What treatment does it provide? • Type of therapy CPAP and bilevel pressure support. Product Therapy mode Pressure VPAP IV CPAP, S 2 – 25 cmH2O* ** VPAP IV ST CPAP, S, ST, T 2 – 25 cmH2O* * 4 – 20 cmH2O in CPAP mode ** 4 – 25 cmH2O in German VPAP IV 26013 • Type of patients – Respiratory Insufficiency and Obstructive Sleep Apnea – Patients in the hospital and home 2 VPAP IV/ST June 08 © ResMed VPAP IV and VPAP IV ST Trusted VPAP performance now in Easy-Breath Technology platform • Half the size, light and compact • Whisper-quiet performance • Faster rise time, enhanced new Vsync • ResScan data card, Reminders, Review menu 3 VPAP IV/ST June 08 © ResMed Features Compact, powerful and comfortable – Popular S8 design – Powerful: More than 140 L/min flow at 25 cmH2O – Easy-Breath Technology Whisper-quiet High performance motor – ResScan data card – New Vsync algorithm – Safer with supplemental oxygen – Fine tuning with TiControl and 5 levels of trigger and cycling sensitivities 4 VPAP IV/ST June 08 © ResMed S8 design - half the size of VPAP III series • From 2.3 kg to 1.3 kg • Popular and compact S8 form – common look and feel • Pressure range 2 – 25 cm H2O • Better pneumatic performance (more flow, faster rise time) 5 VPAP IV/ST June 08 © ResMed Compatible with leading ResMed masks Nasal Masks – – – – Mirage Micro™ Ultra Mirage™, Ultra Mirage™ II Mirage Activa™ Mirage Vista™ Nasal Pillows – Mirage Swift™, Mirage Swift™ II Full Face Masks – Mirage Liberty™ – Mirage Quattro™ – Ultra Mirage 6 VPAP IV/ST June 08 © ResMed Using humidifiers • The heated humidifier H4i™ attaches to the front of the VPAP device. • VPAP automatically detects the H4i, and no menu changes are required. • The H4i seamlessly integrates with the VPAP for superior humidity • 30% more humidification (compared with H3i) • Choices of cleanable water chambers (standard) and disposable (accessory) water chambers 7 VPAP IV/ST June 08 © ResMed Adding oxygen • Oxygen can be added at the ResMed oxygen connector port (26960) • Validated up to 15 L/min O2 • FiO2 will vary, depending on the pressures, patient breathing pattern, mask (exhaust vent flow) and the leak 8 VPAP IV/ST June 08 © ResMed Safer supplemental oxygen Oxygen VPAP • Safer therapy with oxygen up to 15 L/min • Proprietary design (patent pending) maximises oxygen flow to the patient and enhances safety by reducing the chance of oxygen flowing back to the device. • VPAP IV and VPAP IV ST have improved sealing air path. 9 VPAP IV/ST June 08 © ResMed AB filter and battery • Antibacterial filters can be used • Low impedance filters (e.g. less than 2 cmH2O at 60 L/min) are recommended • Triggering and cycling may be affected due to the increased resistance in the air circuit • The VPAP can be powered by a battery using an inverter or ResMed DC 24V converter (26932) • DC 24V converter should not be connected to the VPAP when the it is connected to AC power supply. This may generate electrical interference • If, by accident, AC and DC are connected simultaneously, VPAP runs from AC power and automatically switches to DC when AC power is lost 10 VPAP IV/ST June 08 © ResMed VPAP keypad and LCD 11 VPAP IV/ST June 08 © ResMed Delivering therapy • Without Smart Start/Stop • With Smart Start/Stop* 1.Connect the power cord (no power switch on the device) 1.Turn the power on (No power switch on the device) 2.Fit the mask 2.Fit the mask 3.Press Start/Stop key 3.Breathe into the mask to start 4.Remove the mask to stop NOTE Selecting Full Face Mask and Leak Alert automatically disables the Smart Start/Stop (see Notes) 12 VPAP IV/ST June 08 © ResMed Ramp and H4i Warm-up • Ramp or Settling time allows VPAP to slowly increase the pressure over the selected time • Warm-up feature allows the water in the humidifier to warm up prior to starting treatment • When selected, Ramp or Settling appears after the Welcome screen • When the H4i is attached and the VPAP is powered, a display of warm up will appear 13 VPAP IV/ST June 08 © ResMed Mask-fitting feature • The mask-fitting feature helps the patient adjust the mask to effectively minimise leak • While checking mask fit, VPAP delivers pressure similar to therapy pressure (IPAP) for three minutes Hold down for 3 seconds 14 VPAP IV/ST June 08 © ResMed The mask fit has a star rating up to five stars. Achieving a rating of three stars is effective. Note: VPAP copes well with leak so please DO NOT tighten the mask headgear straps. VPAP S & ST benefits for patient • Enhanced comfort, compliance and convenience: – Compact and convenient S8 form – Easy-Breathe Technology: Whisper-quiet motor Fast rise time and quick response – – – – – Reminders (eg., to change mask, air filter) Better adherence with ResScan data card Comfort and effective humidification with H4i Selection of simplified and advanced Patient menu Synchronization with TiControl and 5 sensitivities 15 VPAP IV/ST June 08 © ResMed VPAP S & ST benefits for clinicians – Data Card for simple efficacy data & settings transfer – Patient reminders (e.g. change mask) to ensure long term management – Easy set-up by two layers of Clinical settings menus – Treatment screens for real time therapy information – SpO2 and HR on LCD by Reslink and oximeter – High resolution Flow data on ResScan – Adequate humidification by H4i – Reliable Vsync technology – Fine tuning by TiControl and 5 sensitivities 16 VPAP IV/ST June 08 © ResMed Leak management - Vsync Essential for successful NPPV therapy Vsync monitors and compensates for leak by continuously and automatically adjusting the baseline flow therapy maintaining reliable triggering and cycling. 17 VPAP IV/ST June 08 © ResMed Ti Control Inspiratory time control (S and ST mode) • Ti Control provides minimum and maximum inspiratory time limits. • The minimum and maximum time limits are set at either side of the patient’s ideal spontaneous inspiratory time, providing a ‘window of opportunity’ for the patient to spontaneously cycle to EPAP. 18 VPAP IV/ST June 08 © ResMed Wide Trigger sensitivity Breath detection sensitivity to initiate IPAP is broadened from 3 to 5 levels. More fine tuning to suite individuals. 5 Trigger sensitivities Very High Very Low Very High Quick to trigger 2.4L/min High Sensitive 4 L/min Med Default 6 L/min Low Less sensitive 10 L/min Very Low Slow to trigger 15 L/min (Design specification) 19 VPAP IV/ST June 08 © ResMed Wide Cycle sensitivity Breath detection sensitivity to cycle down to EPAP is broadened from 3 to 5 levels. More effective cycling for restrictive lungs. 5 Cycle sensitivities Very High Very Low 50 % of Very High Quick to cycle High Sensitive 35% Med Default 25% Low Less sensitive 15% Very Low Slow to cycle 8% peak flow (Design specification) 20 VPAP IV/ST June 08 © ResMed Patient menu simplified Standard menu or Advanced menu Standard Menu 21 VPAP IV/ST June 08 © ResMed Advanced Menu Clinical menu Settings and Advanced Settings Therapy Set-Up Fine-tuning Therapy 22 VPAP IV/ST June 08 © ResMed ResScan Data Card Standard accessory for easy two-way data transfer The ResScan Data Card enables to (1)gain remote access to the data stored in the VPAP device (2)update therapy settings. The S8 Data Card stores: – Device settings – 180 Summary Sessions of patient’s data – 2 Detailed Sessions of patient’s data 23 VPAP IV/ST June 08 © ResMed Patient Reminder • Recurring reminders allow the clinician to set reminders to alert the patient to specific event at set time intervals. • Reminders are; – Replace mask – Replace filter – Service Due – Call provider – Insert Card – Customized message (up to 16 characters) • In 7-day increments for a recurrence period of 1 - 24 months 24 VPAP IV/ST June 08 © ResMed S8 ResLink Optional detailed monitoring VPAP on-board data storage: – 5 detailed sessions – 365 summary sessions Increase data storage and get SpO2 with S8 ResLink: – 30 detailed sessions – 365 summary session – High resolution (25Hz) Flow data SpO2 and HR on VPAP LCD via ResLink and oximetry 25 VPAP IV/ST June 08 © ResMed High res FLOW data 26 VPAP IV/ST June 08 © ResMed New carry bag More premium, professional look and feel 27 VPAP IV/ST June 08 © ResMed
© Copyright 2024