Current Probe The F-10 is used to measure currents on 50Hz, 60Hz, and 400 Hz power lines. The F-10 current probe has a transfer impedance of .25Ω from 2kHz to 2MHz. The F10 has a usable frequency range overlapping the fundamental powerline frequencies. It can handle 350 amperes of primary power line currents from DC to 400 Hz without saturation. -1 3 -2 3 -2 8 F-10 Tranfer Impedance (dB ohms) -1 8 -3 3 -3 8 -4 3 10H z 100H z 1kH z 10kH z F re q u e n c y 100kH z 1M H z 10M H z F-10 Specifications Frequency: Internal diameter: External diameter: Height: ZtΩ1: dBΩ1: 100 Hz – 3 MHz 32mm 94mm 64mm 0.25 −12 Connector: Type-N DC to 60 Hz: 350 amperes 400 MHz: 350 amperes RF(CW): 100 amperes Pulse2: 100 amperes 1: Probe calibrated with 50Ω+j0Ω Load Impedance 2: Depends upon the pulse width and pulse rep. Rate. Fischer Custom Communications, Inc. 20603 Earl St., Torrance, CA 90503 · Phone: 310-303-3300 Fax 310-371-6268 · email: Sales@fischercc.com © Fischer Custom Communications, Inc. 072803DS-F-10 All rights reserved • Printed in USA