ELECTROSTATIC HAZARD ASSESSMENT Venue – Suba International, Andheri East, Mumbai 13th MARCH 2015 (0900 – 1700 hrs.) CHILWORTH TECHNOLOGY PVT. LTD. Muskaan Complex, Plot-3, B-2 501, Dilkalp Chambers, Veera Industrial Estate Vasant Kunj, New Delhi – 110070 Veera Desai Road, Andheri (W), Mumbai - 400053 +91 11 26136979 +91 22 66942350 +91 11 26135979 +91 22 66942351 info-in@chilworthglobal.com info-in@chilworthglobal.com www.chilworth.co.in www.chilworth.co.in ELECTROSTATIC HAZARD ASSESSMENT Introduction Course Contents: Charge is intrinsic to all materials, in that atoms Basis Theory and Definitions comprise both positively charged protons and Electrostatic hazard negatively charged electrons. When the o Understanding the flammability, positive charges exactly balance the negative ignition sensitivity and electrostatic charges, the material is said to be uncharged or properties of the gas (es), liquid(s) and neutral and, at least at a macroscopic level, it dust(s). exhibits no effect due to charge. If, for whatever o reason, the material acquires an excess of Hazard assessment, shocks, fire & explosion negatively charged electrons, it is said to be o Static Discharges negatively charged. Conversely, if it loses some Explosion Protection Techniques electrons it is said to be positively charged. Measures to eliminate and/or control the Whether an object is positively or negatively potential of the static caused fires and/or charged, is referred to as its polarity. explosions. Electrostatic frequently charging in Electrostatic therefore industrial charging occurs process can occur plant. by tribocharging, induction or corona. Who Should Attend? Top management handling HSE functions Decision Makers Process and HSE technocrats The greatest and most common hazard Plant Managers resulting from static electricity arises because Project Managers the small sparks that are simply annoying in our Process Control Specialists everyday Risk Assessors Management Representatives Line Managers world can easily ignite many flammable materials that are found in industry. Indeed, even sparks that are far too small to be felt by people can readily ignite many of the most common industrial substances. Hence From the following industries: static in many industrial environments can and Petrochemical refineries does lead to fires and explosions causing injury Oil and Gas exploration Units and even death to people, destruction of plant, Pharmaceuticals & Manufacturing (PI) and loss of business. Basic Chemicals Any process plant that handles or processes Agro Chemicals, Polymers, resins. flammable liquids, dusts, gases or vapours is at risk from electrostatic induced ignition. Course Registration: Course Fee: 12,500 INR (Twelve thousand five hundred) per participant + service tax as applicable. Please note the course does not include the cost of travel, lodging and boarding of the participant. Registration is on first cum first serve basis. For Registration, please send the filled registration form along with the course fee to our Delhi office. Please note the course does not include the cost of travel, lodging and boarding of the participant. A maximum of 25 participants are allowed per training session. Course fee can be sent through Cheque/ DD/ in favour of Chilworth Technology Pvt. Ltd., payable at Delhi / Mumbai and must be paid before the start of the course i.e. up to registration time. Course fee can also be sent through RTGS/NEFT, the Details are as follows: Beneficiary’s Name: Chilworth Technology private Limited Bank Name/Branch Name; ICICI Bank, New Delhi Swift Code ICICINBBCTS Bank Account Number: 000705018701 Account Type (SB/CA/CC): CURRENT ACCOUNT Address 9A, Phelps Building, C.P New Delhi-110001 Branch IFSC Code ( Applicable only for RTGS ICIC0000007 Payments): Cancellations: All reservations in writing are subject to cancellation conditions. Written cancellations, received up to 5 working days before the course date will be fully refundable. Cancellation within 5 working days are not allowed, however, substitutions can be made. No refunds will be made for non-attendance. Substitutions may be made at any time up to the start of the course. Chilworth Technology reserves the right to modify or cancel the course up to 4 working days prior to the commencement date. REGISTRATION FORM Please book me for: Electrostatic Hazard Assessment – 13th March 2015 Enclosed herewith Cheque / DD / NEFT Receipt in favour of “Chilworth Technology Pvt. Ltd.” for Rs. _____________________ dated _____________, drawn on ________________ Name of the Participant(s) Dr. /Mr. / Ms.: ______________________________________________________________________ Designation/ Job Title: ______________________________________________________________________ Company Name: ______________________________________________________________________ Address: _______________________________________________________________________ _______________________________________________________________________ Pin Code: ______________________ Country: ________________________ Mobile Email : _________________________ Date : _________________________ : ______________________ Signature: ______________________ FOR DETAILS CONTACT: Ms Mamta Sharma Ms Sonal Gaur Mobile: +91 98717 72345 Mobile: +91 8800796685 Landline: +91 11 26136979 Landline: +91 11 26136979 Fax: +91 11 26135979 Fax: +91 11 26135979 Email: msharma@chilworthglobal.com Email: sgaur@chilworthglobal.com
© Copyright 2024