Flyer ibaPDA-S7

Hardware
Software
Training
Applications
ibaPDA-S7-Analyzer
In brief
■■ Data acquisition system for SIMATIC S7 with interfaces
for measurement:
- Ethernet TCP/IP
- Profibus
- MPI
■■ Works also with WinAC and PLCSIM
■■ Sampling time based on S7 system services
■■ 64 signals to be measured, more on request
■■ Signal selection by address book browser or
drag and drop (with CFC-plans)
■■ Range of functions like ibaPDA-V6
■■ Can be installed on Siemens programming device
(PG), no additional PC required
ibaPDA-V6
■■ Data acquisition and data analysis can be performed
independently or at the same time
■■ ibaAnalyzer included
■■ Also available as plugin for ibaPDA-V6
■■ Group licenses for departments and companies
Measurement from the beginning
The software product ibaPDA-S7-Analyzer has been de­
signed especially for automation suppliers, PLC engineers,
service technicians and commissioning engineers. It enables the user to measure and record signals of a SIMATIC
S7 PLC for a fair price if a scan cycle synchronous sampling
is not absolutely required. Potential error sources can be
located easier and eliminated already during engineering.
iba AG offers more communication solutions for measurements made synchronous with the PLC scan cycle.
Low-cost ibaPDA-System for SIMATIC S7
For measuring and recording of global S7 operands
(I, Q, M, PI, DB) and CFC-connectors from supported
SIMATIC S7-3001), S7-4001), S7-12001) and S7-15001) and
in conjunction with the Soft-PLC WinAC (WinLC RTX) and
the simulation tool PLCSIM2). All standard functions of
ibaPDA-V6 apply.
64 signals (and more)
Up to 64 signals in total can be measured. The shares
of digital and analog signals are variable. Signals are
all measurable S7 operands and connectors of the
blocks (FC and FB) in the S7 PLC plan. If ibaPDA-S7Analyzer is used as a supplement with a standard
ibaPDA‑V6 system, more than 64 signals can be measured.
Full analysis function
ibaPDA-S7-Analyzer creates data files (*.dat) which can
be analyzed by the standard tool ibaAnalyzer. The user can
take advantage of the entire range of ibaAnalyzer’s analysis functions. Due to the separation of data acquisition and
data analysis it is possible to do the analysis in parallel to
the acquisition or later.
Use it on SIMATIC programming device (PG)
Due to the integration of the Siemens PG interfaces in the
I/O management of ibaPDA-S7-Analyzer the system can
run on a SIMATIC PG. No further PC is required.
1)
Subject to technical modifications by SIEMENS and special models
2)
Tailored interfaces
Depending on the hard- and software equipment there are
different access points available for data acquisition.
TCP/IP: The connection to the SIMATIC S7 is established
over CPU3) or CP boards in the PLC and the standard network interface of the PC. No Siemens software needs to be
installed on the PC for measurement.
PC/CP: This collective label stands for 4 different access
points which are SIMATIC-specific.
MPI, Profibus: Connection to the MPI, resp. Profibus interface of SIMATIC S7. Adapters for a serial, USB or TCP/IP
interface can be used at PC side.
TCP/IP, ISO: The connection to the SIMATIC S7 is established either over the standard network interface of the PC or
an appropriate PC card.
Please note that the appropriate hardware drivers must be
installed on the PC for all access points of the PC/CP group
(e. g. MPI-USB-adapter, SOFTNET or other).
Drag and Drop
Easy to configure
ibaPDA-S7-Analyzer can detect automatically the active
CPUs and CPs which can be reached over the interface.
They are displayed in the I/O manager and can be assigned
to a measurement module simply by mouse click.
Convenient signal selection
The selection of signals to be measured can be done conveniently in the ibaPDA I/O manager either by entering the
operand address or by browsing through the address books
(can be used in Step7 projects) and selecting the symbolic
name of the signal.
When using the Step7 CFC-editor (v 6.0 or higher) on the
same PC the signals or connectors to be measured can be
dragged directly out of the PLC plan and dropped into the
signal table of ibaPDA-S7-Analyzer.
Does not run on Windows 7
3)
ibaAnalyzer
Only CPUs with Ethernet port supporting TCP/IP
www.iba-ag.com
ibaPDA-S7-Analyzer TCP/IP
PLC type
S7-300®, S7-400®, S7-1200®1), S7-1500®1),
WinAC (WinLC RTX)
CPU or CP of SPS
S7-300: CPU2) or CP343-1
S7-400: CPU2) or CP443-1
Interface board of PC or PG
Access to S7 process data via Ethernet TCP/IP
without Siemens software on the PC
Standard network connection
Access via absolute operands only
2)
Only CPUs with Ethernet port supporting TCP/IP
1)
ibaPDA-S7-Analyzer PC/CP (Profibus, MPI, TCP/IP ISO)
PLC type
S7-300®, S7-400®
CPU or CP of SPS
all CPUs
Interface board of PC or PG
CP 5511, CP 5512 ... PCMCIA-card ... MPI
CP 5611 ... PCI-card ........... MPI/Profibus
CP 5613 ... PCI-card ........... Profibus
Access to S7 process data via Profibus/MPI,
using Siemens communication hardware
(or other brands)
PLC type
S7-300®, S7-400®
CPU or CP of SPS
all CPUs
Interface board of PC
MPI-PC Adapter USB
MPI-PC Adapter serial
Access to S7 process data via USB or serial interface
PLC type
S7-300®, S7-400®
CPU or CP of SPS
S7-300: CPU1) or CP343-1
S7-400: CPU1) or CP443-1
Interface board of PC or PG
CP 1613 ... PCI-card …….... TCP/IP/ISO
Std. network connection with SOFTNET
Access to S7 process data via TCP/IP or ISO
1)
Only CPUs with Ethernet port supporting TCP/IP
Order number
Item
Remark
30.681401
ibaPDA-S7-Analyzer
Single user license
30.681410
ibaPDA-S7-Analyzer-Enterprise-10
License for 10 users
31.001041
ibaPDA-Interface-S7-Analyzer
Add-on license for extending an ibaPDA system with S7-Analyzer
function. A license allows up to 16 connections and can be used up to
15 times per ibaPDA license (= 240 connections).
System requirements
■■ IBM-PC compatible computer or laptop computer with MS Windows XP, Server 2003, Server 2008, Vista or Windows 7
■■ For PC/CP connections SIMATIC NET/SOFTNET or the appropriate drivers must be installed on the PC
■■ For using Drag and Drop the S7 CFC editor must be installed on the PC
SIMATIC S7, S7-300, S7-400, S7-1200, S7-1500 and SIMATIC NET are registered trademarks of Siemens AG. Windows is a registered trademark of Microsoft Corporation
iba AG
Koenigswarterstr. 44 • 90762 Fuerth • Germany • Phone: +49 911 97282 0 • Fax: +49 911 97282 33 • E-Mail: sales@iba-ag.com • www.iba-ag.com
Messtechnik- und Automatisierungssysteme
Measurement and Automation Systems
Flyer_ibaPDA-S7-Analyzer_v1.6_en 01/2014 Technical changes reserved
Order information