Neolith Slip Resistance Test

Johnson España
División Antideslizantes
Avda. M-40, nº 5 - 7
28925 Madrid
Madrid – España
Tlf. (00 34) 913 57 13 22
Fax (00 34) 913 57 18 20
Alamb. Comb. Grande Guerra, 107. 2º
2750 Cascais
Lisboa – Portugal
Tlf. (00 351) 21 482 21 02
Fax (00 351) 21 482 21 02
johnson@johnsonesp.com
56 Gloucester Road
Kensington. Box No 332
SW 7 4 UB
London – U.K.
Fax 020 75819213
REF:. 2011001615/
DETERMINATION OS SLIP RESISTANCE.
TREATMENT EFFECTIVENESS:. SIZE OF SINTERED CERAMICS, SA
C / Del IBERSID - Cami Pol Fund - Almazora
Castellón
The treated areasSLIP:.
EXAMPLE MODEL TILE ARANCIO held
With out implementation of the Johnson landslide tunnel
TESTS:.
Determination of slip resistance to the following standards:
- DB Technical Building Code. UNE ENV 12633
- European Directive 89/654. European Committee for
Standardization. ENV ISO 10545-17
- American Standard C-1.028/85
- Standard DIN 51130
- Standard DIN 51097
MEASUREMENT DATE:. 03/06/2011
UNE 12633:2003 ENV DETERMINING SLIDING RESISTANCE DESIGNATION OF
STANDARD UNE-EN 12633:2003:
•
USRV measuring coefficient of friction of the pendulum is made in both directions.
At each point of measurement is carried out 5 shots with the pendulum, as
indicated by the average of the last three readings UNE-EN 112633:2003.
For each tile tested was chosen an area of its front. This area has been tested
using the sliding shoe width of 76.2 mm, a length of 25.4 mm and a thickness of 6.4
mm rubber. Tested clean length is 126 mm and the reading is done on the scale of
C the device, according to the temperature calibration procedures and included in
the UNE-ENV 12633:2003, approved by the European Committee for
Standardization.
TEST CONDUCTED:
DB tested by the Technical Building Code, the application of VNS 12.633:2003 UNE
Measuring the specific area is classified internally as a general reference that details the
area where the measurement is made:
TEST TUBE ADDRESS:
SAMPLES OF ADDRESS A:
Testtube1: Rd 19 – Testtube 2: Rd: 18 – Testtube 3: Rd 17 –Testtube 4: Rd 17 – Testube
5: Rd 17
SAMPLES OF ADDRESS B:
Testtube1: Rd 19 – Testtube 2: Rd: 17 – Testtube 3: Rd 17 –Testtube 4: Rd 17 – Testube
5: Rd 17
RESULTS: RD: 17 Category: 1
Classification slippery AS INDICATED IN THE NEW BUILDING CODE TECHNICAL.
SOIL CLASS OBLIGATIONS ACCORDING TO YOUR LOCATION
DETERMINATION OF ISO STANDARD SLIDING RESISTANCE ENV 10545-17
European Committee for Standardization. ENV ISO 10545-17
APPOINTMENT OF ENV ISO 10545-17:
Results wet: 0.23
Results dry: 0.34
The measurement of dynamic coefficient of friction, self-propelled by a device called
Friction FLOOR, advancing 17 mm with a rubber foot and a constant mass of 200 grams,
with a constant vertical force, which is a meter to test dry wet.
EUROPEAN DIRECTIVE 89/654/EEC of the Council of 30.11.1989 on the minimum
safety and health in the workplace indicates that soils should be slip resistant.
Sample Results
DETERMINATION OF SLIP RESISTANCE STANDARD C-1028/85
COEFFICIENT OF STATIC FRICTION C-1028/85 STANDARD
DESIGNATION OF STANDARD C-1028-85.
Was measured by an apparatus of ASM, measuring the force of friction. The measurement
is made in four different directions, measuring wet and dry, averaged over the same.
Sample Results:
Readind wet: 40
Reading dry: 47
DIN 51130 STANDARD DESIGNATION
DETERMINATION OF SLIP RESISTANCE DIN 51130 STANDARD
The test method of DIN 51130 standard defines five types of parameters to determine the
slip of a pavement in f unction of the maximum slope of each of which can travel safely.
Sample Results
Angle:. 16 º
Category according to EN: R10
DETERMINATION OF SLIP RESISTANCE DIN 51130 STANDARD
DIN 51097 STANDARD DESIGNATION
The test method of DIN 51097 standard, this test is performed on a device in which the
person performing the test, walking barefoot on a plane sloping at different angles. The
surface to be covered with tile to be tested and continuously impregnated with a soap
solution.
The tilt angle can still stand safely without slipping, is the measure of the trial.
SAMPLE RESULT: 24ª CLASS A
The results to which this report relates only to the objects under test. The report must be