NIRAPOD 4 Low Voltage Air Circuit Breaker 800A-6300A,1000V 40kA-150kA an innovative user friendly circuit breaker with microprocessor control unit for protection and measurements as standard suitable for all applications in: > Industry > Infrastructures > Constructions > Utility ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Presentation NIRAPOD 4 air circuit breakers are designed and made incorporating universal control unit NIRAPOD4.02M/H having protection, control & measurement functions. They may be installed in main LV switchboards as incoming units, main and secondary outgoings. NIRAPOD 4 acb offers a complete range with a large selection of performance level: J ratings from 800 to 6300 A AC, J breaking capacity from 40 to 100 kA rms; J operational voltages 690V AC 1000V DC NIRAPOD 4 circuit breakers are equipped with microprocessor- based electronic control units. All the protection functions are powered by the AC system and no auxiliary power supply is required. The same is true for most of the complementary functions. NIRAPOD4.02M/H control units measure the true rms value of the current Voltages cosϕ, Hz, kW, reading and are therefore not affected by harmonics that may be present on the system. Operating safety The insulating casing of NIRAPOD 4 circuit breakers provides for: NIRAPOD 4 circuit breakers comply with all the major international standards: J user safety: j double insulation on the front face (class II) J International standard IEC 947-2 They also comply with j auxiliary circuits in a compartment insulated from the the following national standards: power circuits J Germany VDE 0660 J switchboard safety when the circuit breaker is in the open J United Kingdom BS 4752 position J Italy CEI j each pole is effectively isolated in its own housing Adex circuit breakers comply with the specifications of the j limitation of external disturbances marine classification companies Positive contact indication The position indicator cannot indicate "open" unless the poles are effectively separated by the required distance. The circuit breakers automatically open during racking in and out. Tropicalisation reliability As standard, NIRAPOD 4 circuit breakers are designed J NIRAPOD 4 circuit breakers comprise ten times fewer for tropical conditions with 95% relative humidity at 45oC parts than traditional devices. They are easier to produce or 80% at 55oC, hot and humid climate conditions. They and more reliable. also comply with the following standards: J the design of Adex circuit breakers is modular with delayed I IEC 68-2-30 damp heat differentiation (highest possible number of common parts on I IEC 68-2-2 dry heat all models). The result is shorter delivery times and I IEC 68-2-11 salt spray enhanced reliability. I IEC 68-2-1 low temperatures during storage. Corrosive atmospheres: Special grease or other surface coatings available (please consult us). AB-02 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Standards Ease of installation NIRAPOD 4 is a complete and rationally designed range. J 10 ratings; J wide breaking-capacity levels; J 1 control units covers all the protection & measurement functions J a complete range of auxiliaries and accessories; J numerous versions (three and four-pole devices, fixed and drawout versions, etc.). NIRAPOD 4 circuit breakers are easy to incorporate in switchboards J a single frame size from 800 to 3200 A, thus making for standardised columns; J an upper safety clearance equal to zero due to the arc-chute cover, on both the fixed and drawout versions; J built-in measurement functions in the control units; J auxiliaries are the same for the entire range and may be easily implemented (only a screwdriver is required). NIRAPOD 4 circuit breakers are easy to connect to the main distribution system. J all types of connections are available (horizontal and vertical terminals, front and mixed connections); J connections are possible with bars of any thickness J connection to the input power source is possible on the upper or lower terminals of the circuit breakers. Due to their small size, NIRAPOD 4 circuit breakers can replace most existing circuit breakers. IEC 947-2 This standard provides the user with a better guarantee concerning quality and performance. Circuit breakers are subjected to tests that are more representative of real operating conditions. Definition of the terms breaking capacity: IEC947-2 also clarifies the notion of breaking capacity. J Icu: the ultimate breaking capacity, which must be greater than or equal to the 3-phase short-circuit current at the point of installation of the circuit breaker, a value unlikely to be reached under real conditions; J Ics: the service breaking capacity, generally expressed as a percentage of the ultimate breaking capacity (25,50,75 or 100% of Icu). It corresponds to a short-circuit current that is more likely to be reached under real conditions. The circuit breaker must continue to operate normally after having interrupted a current equal to Ics several times; J Icw: short-time withstand current for circuit breakers belonging to category B (category B refers to circuit breakers with time discrimination and category A to those without time discrimination). Furthermore, IEC947-2 technological advances: takes into account recent J suitability for isolation recognised for circuit breakers having passed special electrical and mechanical test: J industrial earth-fault circuit breakers covered by an appendix; maximum dependability All NIRAPOD 4 circuit breakers are also disconnectors (suitable for isolation) as specified by IEC 947-2. They bear the corresponding symbol on the front cover: J definition of tests designed to ensure coordination between two circuit breakers. This characteristic considerably increases the dependability of the circuit breaker. The conditions specified by IEC 947.2 for this function are: J positive contact indication; J impulse withstand; 8kV at sea level; J very low leakage current, checked on new circuit breakers and on circuit breakers subjected to tests representative of the end of service life. Moreover Adex circuit breakers have a double- insulation front face (i.e.a class II device) allowing control from the outside. installation NIRAPOD 4 circuit breakers may be installed on horizontal metal surfaces or on rails. They are secured by four points accessible at the bottom of the chassis (drawout versions) or on either side of the circuit breaker (fixed versions.) A single door cut-out is required for the entire range and provides access to NIRAPOD 4 controls. AB-03 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Model NIRAPOD 4 control unit NIRAPOD 4.02M/H basic protection long time protection LT adjustable current setting (Ir) in 2% steps J Ir = In x ... 0.4 to 1 tripping range between 1.05 and 1.20 x Ir time delay (tr) adjustable accuracy :+0 -20% tr at 1.5 Ir (s) 15 30 60 120 240 480 tr at 6 Ir (s) 0.94 1.88 3.75 7.50 15 30 tr at 7.2 Ir (s) 0.65 1.30 2..60 5.20 10 21 adjustable pick-up (Im) in 4% steps Im = Ir x ... 0.4 to 15 W 10% time delay (tr) tm setting with I2t OFF 0.09 0.18 0.27 0.36 tm setting with I2t ON 0.09 0.18 0.27 0.36 max. overcurrent time before tripping (ms) 60.9 140.9 230.9 350.9 max. break time (ms) 140.9 230.9 350.9 500.9 short time protection ST J Instantaneous protection I J fixed pick-up I (kA) see technical data page pick-up (I) adjustable in 8% steps from In to fixed pick-up (mini at 1.6 kA) accuracy W 15% OFF switch on front face on types N1 and H1 basic functions fault indication J for tripping on a fault button on front face fault trip alarm contact J for Ir setting overrun LED on front face J self powered J indication of fault type LEDs on front face J and value of interrupted current self-monitoring display on ammeter J internal overheating and microprocessor errors J self-powered J integrated test J The electrical operating mechanism includes: Electrical operating mechanism J the gear motor J a closing release J a shunt release or an undervoltage release for opening; J "springs charged" limit switch changeover contact The addition of the electrical operating mechanism does not alter circuit breaker dimensions. Added to the manual charging mechanism, a motor charges and automatically recharges the stored-energy spring upon breaker closing making possible fast O-C-O cycles Opening and closing operations are instantaneous. The manual mechanism remains available for emergency use. characteristics power supply 50/60 Hz (V) consumption (VA) DC (V) consumption (W) motor start-up surge charging time geared motor 100/127 - 200/240 - 250/277 - 380 - 415 - 440 - 480 180 24/30 - 48/60 - 100/125 - 200/250 180 2 to 3 In for 0.1 s 3 to 4 s AB-04 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker NIRAPOD 4 In = NIRAPOD 4.02H Controller Protection & measurement N The NIRAPOD4.02M/H control unit is used as standard for protection, measurement and supervision functions. The liquid crystal display and function keys ensure high accuracy and easy adjustment. The standard NIRAPOD4.02M/H control unit provides the following: 1 V 2 3 Hz COS kW V I L2 L1 J universal protection for overcurrent, short circuit & earth faults with different level & adjustable characteristics L3 X10 % J measurement with digital display I, V, kW, cosϕ, Hz, kA, t A/kA J setting & measurement with digital display I, kA, t S J indication of fault type Ic1 J values of interrupted currents Ic2 N δ If S L s J integrated on-load test, trip/no trip conditions. I2t ON tr LT time delay (tr) I2t OFF ST pick-up (Im) ST time delay (tm) tm Instantaneous pick-up (I) th 0 Ir Im I A overcurrent settings 1 : LT setting Ir (long time) 2 : LT time delay tr (long time) 3 : ST pick-up Im (short time) 4 : ST time delay tm (short time) 5 : INST pick-up I (instantaneous) Earth fault protection (option T) I2t ON t I2t OFF T1 T2 0 earth fault protection settings T1 : earth fault pick-up Ih T2 : earth fault time delay th I Instantaneous pick-up (I) th Ih Ir Im I A STATE SET SELECT TEST FAULT FUNCTION ALARM ENTER MEMORY RESET Tx J "earth" protection with time discrimination or zone selective interlocking. The protection is of the residual current type (or source ground return type on request). LT setting (Ir) ST time delay (tm) earth 2fault time delay (th) I t OFF 0 I2t OFF ST pick-up (Im) I2t ON tm J short-circuit protection: j delayed, with short time function ST, for which the I2t curve can be disabled by the user, j instantaneous, with the INST function that can be disabled by the user s I2t ON LT time delay (tr) earth fault pick-up (Ih) Basic functions: long time LT, short time ST, instantaneous INST T LT setting (Ir) tr The NIRAPOD4.02M/H control unit provides: J overload protection, with long time Protection LT including: j adjustable time delay and thermal memory possibility I Controller Setting Programing interface Rx indication and measurement a digital display continuously indicates the current of the phase with the greatest load (lmax), Voltages, cosϕ, Hz, kW, reading. By pressing a scroll button, it is also possible to display successively the readings of I1, I2, I3 & voltage in phases. The display unit also helps setting parameters related to protections & measurement of the programmable control unit. Factory adjustments The NIRAPOD4.02M/H control unit is factory adjusted as follows: LT setting Ir In time delay tr 480 s ST pick-up Im 4 In time delay tm 0,2 s INST pick-up I maxi T earth fault pick-up Ih 0.2 In time delay th 0,1 s load monitor Ic1 In Ic2 In earth fault protection This earth fault protection is designed to protect the installation against the risks of fire due to high earth faults (not to be confused with schemes designed for the protection of persons against electrical shock). Two types of earth protection are available: J residual current type (T): the control unit calculates the vector sum of the phase and neutral (if distributed) currents J source ground return type (W): the control unit acts directly on the signal received from an external current transformer installed on the source earthing circuit. AB-05 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker circuit breakers model number of poles AB08 AB10 3-4 3-4 800 1000 800 1000 1000 1000 8000 8000 690 690 electrical characteristics as per IEC 947-2 and EN 60947-2 rated current (A) In 40oC rating of 4th pole (A) rated insulation voltage (V) Ui rated impulse withstand voltage (V) Uimp rated operational voltage (V) Ue AC 50/60 Hz Icu AC 50/60 Hz type of circuit breaker ultimate breaking capacity (1) (kA rms) service breaking capacity Ics (% Icu) short - time withstand current Icw AC 50/60 Hz (kA rms) making capacity (kA peak) Icm AC 50/60 Hz N1 H1 H2 N1 H1 H2 220/415 V 40 65 100 40 65 100 500/690 V 40 65 85 40 65 85 100% 100% 100% 100% 100% 100% 0.5 s 40 65 65 40 65 65 1s 30 50 50 30 50 50 3s 22 32 32 22 32 32 220/415 V 84 143 220 84 143 220 440 V 84 143 220 84 143 220 500/690 V 84 143 187 84 143 187 84 143 143 84 143 143 electrodynamic withstand (kA peak) utilization category B B suitability for isolation J J break time 25 to 35 ms closing time endurance (C-O cycles) x 1000 70 ms mechanical with maintenance 20 no maintenance electrical no maintenance motor control (AC3-947-4) (2) 20 20 20 20 10 10 10 10 10 10 440 V - In 10 10 10 10 10 10 690 V - In 10 10 10 10 10 10 690 V 10 10 10 10 10 10 installation and connections connection front and rear connections drawout J J fixed J J auxiliary switches J J electronic trip unit related functions J J auxiliary releases J J motor mechanism J J operation counter J J interphase barriers J J terminal - block cover J J door frame J J 3P 290x400x312 290x400x312 4P 550x439x367 550x439x367 3P 290x400x312 290x400x312 4P 537x356x290 537x356x290 version indication and measurement auxiliaries control auxiliaries installation and connection accessories dimensions and weights dimensions W x H x D (mm) drawout fixed 20 AB-06 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker AB12 AB16 AB20 AB25 3-4 3-4 3-4 3-4 1250 1600 2000 2500 1250 1600 2000 2500 1000 1000 1000 1000 8000 8000 8000 8000 690 690 690 690 N1 H1 H2 N1 H1 H2 N1 H1 H2 N1 H1 H2 40 65 100 40 65 100 55 75 100 55 75 75 40 65 85 40 65 85 55 75 85 75 75 85 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 40 65 65 40 65 65 55 75 75 55 75 75 30 50 50 40 50 50 55 75 75 55 75 75 22 32 32 22 32 32 50 57 57 50 75 75 84 143 220 84 143 220 121 165 220 121 165 220 84 143 220 84 143 220 121 165 220 121 165 220 84 143 187 84 143 187 121 165 187 121 165 187 84 143 143 84 143 143 121 165 165 121 165 165 B B B J J J B 25 to 35 ms 70 ms 20 20 20 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 15 15 15 15 15 15 10 10 10 10 10 10 10 10 10 10 10 10 9 9 9 8 8 8 10 10 10 7 7 7 6 6 6 10 10 10 7 7 7 6 6 6 front and rear connections J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J 290x400x312 290x400x312 290x400x312 290x400x356 550x439x367 550x439x367 550x439x367 550x439x367 290x400x312 290x400x312 290x400x312 290x400x356 550x439x367 550x439x367 550x439x367 537x356x290 AB-07 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker AB32 AB40 AB50 AB63 3-4 3-4 3-4 3-4 3200 4000 5000 6300 3200 4000 5000 6300 1000 1000 1000 1000 8000 8000 8000 8000 690 690 690 690 H1 H2 H1 H2 H1 H2 H1 H2 75 100 75 100 100 150 100 150 75 85 75 85 85 85 85 85 100% 100% 100% 100% 100% 100% 100% 100% 75 75 75 75 100 100 100 100 75 75 75 75 100 100 100 100 75 75 75 75 100 100 100 100 165 220 165 220 220 330 220 330 165 220 165 220 220 330 220 330 165 187 165 187 187 187 187 187 165 165 165 165 220 220 220 220 B B B J J J J 25 to 35 ms 70 ms 15 15 10 10 10 10 5 5 4 4 3 3 2.6 2.6 2.5 2.5 2.6 2.6 2.5 2.5 front and rear connections 10 10 10 10 5 5 5 5 3 3 2 2 2.5 2.5 1.5 1.5 2.5 2.5 1.5 1.5 rear connections J J J (3P only) J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J 290x400x370 290x400x370 290x400x370 290x400x370 550x439x367 550x439x367 550x439x367 550x439x367 290x400x370 290x400x370 290x400x370 290x400x370 537x356x290 537x356x290 537x356x290 537x356x290 AB-08 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Communication Network: Nirapod4.02H Controller Through Modbus-Rtu, Profibus-DP or Device-Net. The RS485 connection, address and baud rate can be set through the programmer. The “four remote” function, remote measuring, remote communication, remote control, and remote modifying can be realized through the communication interface. ST-DP is the communication module. The master station card is SIEMENS’s CP5X11,RTis the resistance of the network terminal,usually 150 ohm. Rt RS232 RS485 Converter Monitoring PC NIRAPOD 4.02H Modbus Communication Module To be used with the H type controller for converting from Modbus-Rtu to Profibus -DP. Auxiliary power is AC/DC 220V Dimension diagram: Communication Interface T04 To be used in switchboard for communication connection with the breaker. (Encoded as 2 in the Switchboard diagram) Communication Line For the connection with various communication terminals, A shielding twisted-pair is OK for this purpose. When ST-DP is used, T215-01 is needed;when ST-DN is used, T415-01 is used. AB-09 NIRAPOD 4.02H NIRAPOD 4.02H ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker drawout wiring diagrams CHASSIS AUXILIARIES CONTROL UNIT - CN + CN 1 BREAKER AUXILIARIES Fu N P1 S1 P2 S2 AT (4) (2) (4) LR alarm fault closed BPF open springs charged Ic1 Ic2 (5) 372 374 352 354 362 364 disconnected 334 332 344 342 324 322 314 312 connected ready to close BPO Z11 Z12 LR2 T2 T1 V2 R1 R2 e+ e- 82 84 212 222 234 244 12 14 22 24 32 34 42 44 D4 C12 C2 A4 252 254 262 B4 CE or T F V F XF SR OF F M URV SR or UVR-T O O CH SDE ammeter processing unit CD 311 321 331 341 351 361 AT BPO BPF LR CR T CE : : : : : : : M : R XF T : : : SR : UVR : UVR-T: OF : O : F : FTIC : CMS : F : FV : PF : PF C R CT 371 Z21 Z22 LR1 (3) CN 1 ALR F21 F1 V1 C 81 211 221 11 21 31 41 D1 C11 C1 A1 251 B1 power supply (1) Fu - CN - emergency off "open" push button "close" push button long time trip (LT) indicating lamp short time trip (ST) indicating lamp earth fault trip indicating lamp "connected" position contact (10A/240V AC) spring charging motor (180V A/240V AC) load monitoring and control closing release (20V A/240V AC) earth fault protection (EZ and SZ: input and output for zone selective interlocking) shunt release (20V A/ 240V AC) undervoltage release (20V A/240V AC) time delayed undervoltage release (20V A/240V AC) auxiliary changeover contacts (10A/240V AC) 2 auxiliary NC contacts (10A/ 240V AC) 2 auxiliary NC contacts 10A/ 240V AC) fault trip indication contact (10A/ 240V AC) charging motor limit switch contact fault trip local indicator segregated fault trip indication contact (5A/ 240V AC) "ready to close" contact (10A/ 240V AC) (closing possible if breaker is open, not locked and operating mechanism charged) 231 241 CD : "disconnected" position contact (10A/ 240V AC) CT : test position contact (10A/ 240V AC) C : communication. J Ic1: load shedding command according to Ic1 setting Ic2: load shedding command according to Ic2 setting J diagram shown with circuits deenergised, breaker open and in "connected" position, springs charged and relays in released position J accessories such as pushbuttons, lamps and fuses are not supplied with the circuit breaker. Wiring of the UVR-T (modified diagram). Instantaneous tripping with UVR-T when contact 254-262 opens. D4 254 262 UVR-T D1 Note: the wiring of the external contact replaces the spring charged indication and the contact PF. V contact wiring: for breaker locking, depending on the selected fault. (1) Power supply terminals for I or T or F options (AD module with BAT battery module for backup power). (2) Zone selective interlocking with line side breaker. (3) Zone selective interlocking with load side breaker (remove jumper) (4) DC power supply R contacts reset request wiring of an external contact (5) With Z and/ or C options, terminal 84 is not available. AB-10 CN1/CN + BPO V C2 V CN2/CN- V SR C1 Selective locking needs: * external power supply (F1, F2) * an additional terminal (BS) ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Wiring: NIRAPOD 4.02M L1 1 N PE 2 Breaker line side UN U1 U2 U3 SB3 SB2 SB1 external mutual inductor 2 4 6 8 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 QT SHT CC 7 9 13 15 17 19 21 23 25 27 29 31 33 Closed wire 35 37 39 41 43 45 Under voltage release Intelligent controller Energy Main power 47 Auxiliary switch Energy External terminals of NIRAPOD 4.02M Breaker line side External power supply UN U1 U2 U3 External mutual inductor 1 2 4 6 8 10 12 14 16 18 20 22 24 3 5 7 9 11 13 15 17 19 21 23 25 AB-11 26 Together/close 5 Separate 3 Energy Storage 1 Shunt off and control M ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Wiring: NIRAPOD 4.02H L1 1 N PE 2 hub T03 1 Profibus-DP + Connecting wire 1 4 Red Green 8 10 12 14 6 4 N 16 18 20 22 24 5 - PE ST Model IV + - 14 15 - + - 2 3 4 5 + - 16 17 6 7 8 26 28 30 D01 12 13 D02 14 15 34 36 32 D03 16 17 + 18 19 9 DI1 DI2 DI3 D024V DC24V COM Breaker line side UN U1 U2 U3 2 3 L - 12 13 ST-DP Device 2 L N + 10 11 ST201 18 19 38 40 42 44 46 QT SHT CC 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 Separate 3 Under voltage release Intelligent controller Closed wire Energy Main power Shunt off and control Energy Storage 1 Auxiliary switch Energy External terminals of NIRAPOD 4.02H External power supply Breaker line side UN U1 U2 U3 External mutual inductor 1 2 4 6 8 10 12 14 16 18 20 22 24 3 5 7 9 11 13 15 17 19 21 23 25 AB-12 26 47 Together/close M ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker Installation: Fixed circuit breakers AB08 to AB32 dimensions 553 necessary space for removing the arc chutes (with or without arc chute cover 3 or 4 poles 438 493 378 90 130 45 311 (*) (*) 30 mini 60 maxi 400 11 68 150 11 422 (3p) 290 515 11 11 537 (4p) mounting on a base plate Panel cut-outs mounting detail holes for escutcheon X14 155 B 268 A X11 150 3 poles 150 400 A B 30 mini 60 maxi 155 (*) 2 X11 x 6 4 poles 150 515 80 mini 27 37.5 80 mini 302 (*) 11 X5 172.5 172.5 22 Drawout circuit breakers AB08 to AB32 dimensions "disconnected" position 3 or 4 poles 45 311 800 mini 128 60 (*) 55 101 175 325 55 435 (3p) 85 425 70 367 55 550 (4p) (*) mounting Panel cut-outs on a base plate mounting detail holes for escutcheon ACB's side X14 B 155 270 X11 101 175 A B A 3 poles 175 325 2 X11 x 6 155 75 4 poles 175 425 100 mini ACB's basis AB-13 268 55 302 65 100 mini 19 75 20 7 X3 172.5 172.5 17.5 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker installation: Fixed circuit breaker AB40 dimensions 819 necessary space for removing the arc chutes (with or without arc chute cover) 3 or 4 poles 90 45 553 759 493 130 311 (*) (*) 30 mini 60 maxi 150 290 11 515 11 68 537 (3p) 11 780 11 802 (4p) mounting Panel cut-outs on a base plate mounting detail holes for escutcheon X14 B 155 268 A X11 150 30 mini 60 maxi 50 maxi 3 poles 150 515 A B Drawout circuit breaker AB40 dimensions 3 or 4 poles (*) 2 X11 x 6 4 poles 150 780 27 37.5 80 mini 155 80 mini 361 (*) 11 X5 202 22 202 "disconnected" position 45 439 484 (*) 800 mini 128 60 70 (1) 101 175 425 55 550 (3p) 85 60 367 350 350 55 815 (4p) (*) mounting on a base plate panel cut-outs mounting detail 40 holes for escutcheon 40 ACB's side 30 155 350 270 150 (1) 101 175 175 155 75 350 2 X11 x 6 (3p) 6 X11 x 22 (4p) 100 mini ACB's basis AB-14 268 55 302 65 100 mini 75 19 20 7 X3 172.5 172.5 17.5 ISO 9001 : 2008 Certified NIRAPOD 4 Air Circuit Breaker installation Fixed circuit breaker AB50-63 Dimension necessary space for removing the arc chutes (with or without arc chute cover) 3 poles 90 45 819 759 130 311 (*) (*) 30 mini 60 maxi mounting on a base plate 150 11 780 11 68 802 290 mounting detail panel cut-outs holes for escutcheon X14 155 B A X11 150 30 mini 60 maxi 50 maxi 268 155 2 X11 x 6 3 poles 150 780 A B 27 37.5 80 mini 11 X5 80 mini 361 202 202 22 Drawout circuit breaker AB50-63 dimensions "disconnected" position 3 or 4 poles 70 45 484 (*) 800 mini 128 60 60 350 350 101 175 40 85 475 475 1045 (4p) 367 mounting 55 (*) panel cut-outs on a base plate mounting detail 40 40 panel cut-outs 30 holes for escutcheon ACB's side 350 152.5 150 350 (1) 101 55 815 (3p) 175 47 6 X11 x 22 (3p) 6 X11 x 33 (4p) 270 148.5 71.5 19 55 175 325 ACB's basis AB-15 69 45 (1) 100 mini 18.5 11 X5 180 180 17.5 ISO 9001 : 2008 Certified Bitoron-600 Compartmented LV Switchgear incorporating NIRAPOD 4 circuit breakers made in conformity to IEC60439.1 a complete low voltage fully Type Tested Assemblies (TTA) for - industry - infrastructures - construction - utilities Corporate Office : Baitul Abed 53 Purana Paltan (3rd Floor) Dhaka-1000, Bangladesh. Phones : 02-9559868, 9559826 Fax : 02-956 2705 e-mail : info@adexbd.com Web : www.adexbd.com Sales Office : Shakh Centre 56 Purana Paltan (3rd Floor) Dhaka-1000, Bangladesh. Phone : 02- 956 0626 Fax : 02- 956 2705 e-mail : sales@adexbd.com, web : www.adexbd.com Chittagong Office : Bank Asia Bhaban (4th Floor) 69 Agrabad Commercial Area Chittagong, Bangladesh. Phone : 031-2523993 e-mail : adex_ctg@adexbd.com web : www.adexbd.com Factory : West Dogri, Bhawal Mirzapur Gazipur, Bangladesh. e-mail : ael_works@adexbd.com web : www.adexbd.com Q3000-January’14-gd:pulin ADEX ENGINEERING LIMITED.
© Copyright 2024