ASTRAL FLOWGUARD CPVC PIPES AND FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS Corrosion Resistant For Hot & Cold water No electrical tools required Easy cold welding process Lower bacterial growth Fire safety PRODUCT CATALOGUE Safe for drinking water IS 15778 Cost effective CM/L-3673470 st to introduce in india Only those products bearing the NSF mark are certified ABOUT US Astral Poly Technik Ltd is very proud to introduce CHLORINATED POLY VINYL CHLORIDE [CPVC] for the first time into this part of the globe, under license from Lubrizol, [formerly Noveon, USA] under brand name Astral FlowGuard CPVC. It is also manufacturing Industrial Piping System under brand name Astral Corzan CPVC. It has a techno commercial joint venture with Specialty Process LLC, USA, the world leaders of manufacturing FlowGuard CPVC Pipes and Fittings in USA since last 32 Years. Astral FlowGuard pipes and fittings, manufactured by Astral Poly Technik Ltd, are made from the specialty plastic, chemically known as Chlorinated Poly Vinyl Chloride [CPVC]. This CPVC compound meets cell class 23447 B as defined by ASTM D1784 and have a design stress of 2000 PSI and a maximum service temperature upto 93°C. Pipes are produced in copper tube size (CTS) from 15 mm (½") to 50 mm (2") with two different standard dimensional ratios - SDR-11 and SDR-13.5. The fittings are produced as per SDR 11. All Astral CPVC SDR 11 and SDR 13.5 pipes are made from identical CPVC compound material having same physical properties. The CPVC fittings are manufactured from compound material which meets all the requirement as per ASTM standard. CPVC pipes of Copper Tube Size (CTS) dimensions can also be applied to CPVC (IPS) dimensions by using IPS x CTS fittings. The CPVC pipes from 15 mm (½") to 50 mm (2") are also produced as per IS 15778 standard in both class that is Class 1 (SDR 11) and Class 2 (SDR 13.5). Apart from having the same physical properties, SDR 11 and SDR 13.5 which are having different wall thickness and therefore, at any given temperature, they have different pressure ratings. For e.g. Astral also produces FlowGuard pipes in iron pipe size (IPS), available sizes are 65 mm (2½") to 100 mm (4") in SCH 40 and 65mm (2½") to 300 mm (12") in SCH 80 which meets the requirements of ASTM F 441. The pressure ratings varies with schedule pipe size and temperature. Astral is the only pipe manufacturing company in India having most prestigious quality certification from National Sanitation Foundations (NSF) and Bureau of Indian Standards(BIS). Astral products are regularly tested at CIPET, CBRI - Roorkee and Shriram Institute and also received state approvals from BMC, CPWD, PWD, DGMAP etc. for domestic and public sanitation. MARKETING NETWORK : Astral has marketing network of more than 300 distributors and 9,500 dealers spread all over India with branch offices at Mumbai, Delhi, Bengaluru, Chennai and Hyderabad apart from that Astral has it's own warehouses at Bengaluru, Coimbatore, Vijaywada, Goa and Delhi to deliver the material as quick as possible. More than 150 techno marketing professionals and administrative personals are on the board to coordinate with architects, plumbing contractors and plumbers to utilize the best plumbing techniques and to get the best from the product. FIELDS OF APPLICATIONS : Hot and Cold water applications in homes, apartments, hotels, resorts, hospitals, high and low rise buildings, corporate and commercial houses, academic institutes etc. for pure and Pipe SDR 11 SDR 13.5 1 Temperature (°C) 23 Pressure Rating (PSI) 400 (Kg/Cm2) 28.10 82 100 7.00 23 82 320 80 22.50 5.60 hygienic water supply. Factory - Santej, Ahmedabad STANDARDS & SPECIFICATIONS ASTM D1784 – Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds. ASTM D2846 – Specification for Chlorinated Poly ASTM F493 Pipes and fittings made from CPVC compounds shall be clearly marked with the manufacturers trademark, material designation, applicable ASTM standard. (Vinyl Chloride) (CPVC) Plastic Hot & SDR 11 Pipe : Tan coloured with red stripe Cold water distribution systems. SDR 11 fittings : Tan Colour – Standard Specification for Solvent SDR 13.5 Pipe : Tan coloured with brown stripe Cements for Chlorinated Poly (Vinyl SDR 11 fittings : Tan Colour SCH 40 Pipe : Tan coloure SCH 40 fittings : Tan Colour Poly (Vinyl Chloride) (CPVC) Plastic SCH 80 Pipe : Tan colour Pipe, SCH 40 & 80. SCH 80 fittings : Grey Colour Chloride) (CPVC) Plastic Pipe & Fittings. ASTM F441 MARKING AND UNIFORMITY : – Standard Specification for Chlorinated ASTM F438 – Socket-Type Chlorinated Polyvinyl ASTM F439 – Socket-Type Chlorinated Polyvinyl Chloride Plastic Pipe Fittings. SCH 40. Chloride Plastic Pipe Fittings. SCH 80. ASTM D2774 – U n d e r g r o u n d i n s t a l l a t i o n o f Thermoplastic pipes. NSF CERTIFIED : NSF International, a not-for-profit, non-governmental ASTRAL FLOWGUARD CPVC LIMITED WARRANTY Astral poly technik limited - Ahmedabad warrants to the original owner that the product will be free from manufacturing defect and confirm to current applicable ASTM standards under normal use. Buyer’s remedy for breach of this warranty is limited to replacement of or credit for the defective product. This warranty excludes any expense for removal or reinstallation of any organization, is the world leader in standards development, defective product and any offer incidental, consequential or product certification, education, and risk management for public punitive damages health and safety (www.nsf.org). For 65 years, NSF has been committed to public health, safety and environmental protection. The NSF Mark is recognized for its value in international trade and is respected by regulatory agencies at the local, state, and national levels. Astral is the first Indian company to obtain certification from NSF for its CPVC products. 2 WHY PIPE AND FITTINGS ARE THE BEST CHOICE FOR HOT AND COLD POTABLE WATER DISTRIBUTION ? THE RAW MATERIAL FlowGuard™ is a Hot and Cold Potable Water Distribution System made of chlorinated polyvinyl chloride (CPVC) for use in single and multi-family homes, apartments, high-rises, hotel/motels and commercial installations. FlowGuard™ CPVC has been used for hot and cold water distribution in the United States since 1960. It has a history of superior performance and Astral FlowGuard CPVC piping system has winning edge over any other piping systems. Here are few parameters which make Astral FlowGuard hot and cold water plumbing system stands as best in comparison to any other outdated plumbing system… competitive prices compared to metal and other alternative piping systems. CPVC pipe and fittings are jointed by solvent cementing which, through chemical bonding, essentially makes the pipe and fitting become one continuous piece. Flowguard™ CPVC meets requirements of both ANSI/NSF standard 14-plastic piping system components and related materials-and standard APPROVALS ACROSS THE WORLD BY PROMINENT HEALTH AND STANDARDS ASSOCIATIONS 61- Drinking Water System, components-health affects. Included in these tests are strict standards and strict toxicological review • USA relating to chemical extraction products, taste and odour • Germany : Deutscher Verein des Gas-und Wasserfaches : NSF International (DVGW) produced in the water by the piping system. These tests ensure that all Environmental Protection Agency (EPA) standards for • UK : Water Research Council (WRC) safe drinking water are met by the CPVC piping system. • Canada : Canadian Standards Association (CSA) • Holland : Keurings instituut voor Water leiding artikelen (KIWA) • France : Center Scientifique et technique du batiment (CSTB) • Turkey : Turkish Standard Institution (TSE) 3 Factory - Baddi, Himachal Pradesh • NSF APPROVED SOLVENT CEMENT : All Weld-On solvent cements, primers All Weld-On Low VOC solvent cements provide the following benefits : • High Quality Performance with excellent installation properties. for Low VOC (volatile organic • User Friendly. Reduced fumes and odour for the comfort and well being of pipe installers. compound) emission limits • NSF, UPC and/or CSA Listed.* established by the California South • Meet ASTM Standards for solvent cements used for plastic pipe installation.* • Environmentally Responsible. LEED® Compliant (Leadership in Energy and Environmental Design).** * Refer to individual solvent cement for specific ASTM Standards, NSF, UPC and/or CSA Listings. and cleaners meet the requirements Coast Air Quality Management District (SCAQMD), one of the USA's strictest air quality regulatory bodies. Low VOC emissions contribute to cleaner air. ** LEED Green Building Rating System For New Construction & Major Renovations Version 2.2 (Indoor Environmental Air Quality: EQ Credit 4.1 Low-Emitting Materials - Adhesives & Sealants) Astral recommends NSF approved IPS weld on solvent cement for reliable and leak proof joints between CPVC pipes and fittings. 4 5 Test report from Central Building Research Institute, Roorkee CBRI 5.0 Conclusions & Recommendations — Based on generated data during experimental work, “Astral” brand CPVC pipes and fittings have been found suitable for hot and cold water supply in buildings. — “Astral” brand CPVC pipes and fittings meet the requirements of ASTM D 2846 (properties of pipes and fittings) IS: 10500-91 (quality of water) and IS: 10151-82 (overall migration of leachable additives). — Works has been carried out on the samples supplied by the party and the reported results are based on thees samples. 11/25 6 WHY ASTRAL - Quality Assurance Laboratory CPVC ? STATE OF ART MANUFACTURING Astral is equipped with state of art manufacturing facilities at both Ahmedabad and Himachal Pradesh plants. High speed and accurate extruders and injection molding machines including innovative manufacturing techniques being used to manufacture the ultra modern, errorless Astral FlowGuard pipes and fittings. CERTIFICATIONS • NSF and ISI Certifications : Astral the only pipe manufacturing company in India now having most prestigious quality certifications from National sanitation Foundation (NSF) and Bureau of Indian Standards (BIS). IS 15778 Astral now have ISI mark for CPVC pipes CM/L-3673470 APPROVALS IN INDIA pw • Bureau of Indian Standards Approval - ISI marked • NSF certificate for CPVC pipe & fittings (ASTRAL - The only pipe • • • manufacturing company in India now having two most prestigious quality certifications from National Sanitation Foundation and Bureau of Indian Standards.) State Approvals of CPVC System - BMC, CPWD, PWD, DGMAP etc. Tested in India regularly by CIPET, CBRI - Roorkee, Shriram Institute Apart from manufacturing and distributing world class FlowGuard CPVC pipes and fittings, Astral takes care of its products by constantly testing and checking CPVC pipes and fittings in their orld class Quality Assurance Laboratory, where various tests are carried out at regular intervals to exceed the quality levels beyond the industry standards. Astral also takes care of its customers by training plumbers and plumbing contractors throughout the year by updating them about modern plumbing techniques and to do plumbing work more effectively and professionally. 7 ® Only those products bearing the NSF Mark are certified NSF certification for CPVC pipes and fittings. (check NSF website for listing of Astral's products) http://www.nsf.org/Certified/Plumbing/Listings.asp?Company=1S170&Standard=014 Live Safer *NSF International is a non-profit nongovernmental organization that provides standards development, product certification, auditing, education and risk management for public health and safety. NSF is a World Health Organization Collaborating Centre for Food and Water Safety and Indoor Environment. Serving companies in over 100 countries BASIC PHYSICAL PROPERTIES PROPERTY TEST CONDITION ENGLISH UNITS SI UNITS ASTM D792 73°F / 23°C 73°F / 23°C 73°F / 23°C 212°F/100°C 73°F / 23°C 1.55 g/cm3 0.645 cm3 /g +0.03% +0.55% 119 23447-B 1.55 g/cm3 0.645 cm3 /g +0.03% +0.55% 73°F / 23°C 73°F / 23°C 73°F / 23°C 73°F / 23°C 73°F / 23°C 73°F / 23°C 73°F / 23°C 1.5 ft Ibs/in o.n 8000 psi 360,000 psi 15,100 psi 415,000 psi 10,100 psi 196,000 psi 80 J/m o.n. 55 N/mm2 2500 N/mm2 104 N/mm2 2860 N/mm2 70 N/mm2 1350 N/mm2 ASTM D696 3.4x10-5 in/in/°F 6.3x10-5 m/m/°K ASTM C177 ASTM D638 DSC 0.95 BTU in/hr/ft2/°F 217°F 0.21 BTU/Ib°F 0.26 BTU/Ib°F 0.14 Wm/°K/m2 103°C 0.90 J/g°K 1.10 J/g°K GENERAL • Specific Gravity • Specific Volume • Water Absorption ASTM D570 • Rockwell Hardness • Cell class ASTM D785 ASTM D1784 MECHANICAL • Izod Impact • Tensile Strength • Tensile Modulus • Flexural Strength • Flexural Modulus • Compressive Strength • Compressive Modulus THERMAL • Coefficient of Thermal Expansion • Thermal Conductivity • Heat Distortion Temperature • Heat Capacity FLAMMABILITY • Flammability Rating • Flame Spread • Smoke Developed • Limiting Oxygen Index ELECTRICAL • Dielectric Strength • Dielectric Constant • Power Factor • Volume Resistivity ASTM D256 ASTM D638 ASTM D638 ASTM D790 ASTM D790 ASTM D695 ASTM D695 UL 94 ASTM E84 ASTM E84 ASTM D2863 ASTM D147 ASTM D150 ASTM D150 ASTM D257 73°F / 23°C 212°F / 100°C 0.062 in/0.157 cm 60 Hz, 30°F/-1°C 1000 Hz 73°F/23°C V-0, 5VB, 5VA 15 70-125 60% 1250 V/mil 3.70 0.007% 3.4x1015 ohm/cm 492,000 V/cm 3.70 0.007% 3.4x1015 ohm/cm 8 FEATURES & BENEFITS Corrosion resistance Astral CPVC Pipe gives excellent resistance even under the harshest of water conditions so there are none of the purity worries from corrosion of metal pipe or soldered joints. Astral CPVC Pipe keeps pure water pure. Lower bacterial growth Bacteria build up with CPVC is far lower than with alternative piping materials - Copper, Steel and other thermoplastics. No Scale, pit or leach formation Even after years of use in the most aggressive conditions, Astral CPVC pipe won’t corrode, standing up to low pH water, coastal salt air exposures and corrosive soils. Astral CPVC Pipe stays as solid and reliable as the day it was installed. It maintains full water carrying Capacity because its scale resistance means no build up to cause water pressure loss. Unaffected by chlorine in the water Some materials may be adversely affected by chlorine contained in the water supply, which can cause breakdown of the polymer chains and potential leaks. In this respect, Astral CPVC pipe is unaffected by the chlorine present in potable water supply. Low thermal expansion Astral CPVC pipe has a lower coefficient of thermal expansion than alternative plastics, reducing the amount that the pipe expands when hot water is running, again reducing unsightly ‘looping’ of the pipe. 9 Thermal Conductivity 0.30 0.25 Number of Legionella bacteria in the test water 175 Coefficient of Thermal expansion 2.00 0.15 1.75 0.10 125 1.50 (x10-4k-1) 150 cfu/ml 0.20 W/MK 200 0.05 100 0.00 75 CPVC PVC PP PEX PB 1.25 1.00 0.75 50 0.50 25 0.25 0 0.00 CPVC* Stainless PEX* PB* PPR* Steel CPVC PVC PP PEX PB Easy Plumbing process CPVC uses a simple, solvent cement jointing method. Tools required are very simple and inexpensive (chamfering tool and pipe cutter only) and avoid the need for an electrical source. Superior insulation : Astral CPVC pipe is more energy efficient than metal pipe. As an insulator it does not lose heat the way metal pipe do. Heat loss and thermal expansion are reduced. Hot water compatible Astral CPVC pipe is compatible with both hot and cold water. It withstand very high temperature compared to any other thermoplastic plumbing systems. Many solar and electric water heaters have CPVC piping system for heat efficiency and lower installation cost. Tough, rigid material Astral CPVC pipe has a much higher strength than other thermoplastics used in plumbing. This means that CPVC needs less hangers and supports and there is no unsightly looping of the pipe. Astral CPVC pipe Has a higher pressure bearing capability. This leads to the same flow rate with a smaller pipe size. REHTO EPIP CITSALP EPIP CVPC Fire safety CPVC has a limiting Oxygen Index (LOI) of 60. Thus in air, Astral CPVC pipe does not support combustion. No flaming drips, does not increase the fire load, low flame spread, low smoke generation. OTHER CPVC PIPE PLASTIC PIPE Approved world wide CPVC plumbing system is approved for contact with potable water in wide range of countries including USA, UK, Canada, Germany, France, The Netherlands, Middle East among others. Here in India, Astral CPVC plumbing system is approved by BMC and CPWD for potable water supply. Live Safer Astral now have NSF certification for CPVC pipes and fittings. ISI mark for CPVC pipes (check NSF website for listing of Astral's products) IS 15778 pw CM/L-3673470 Only those products bearing the NSF Mark are certified 10 CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846 TRANSITION COUPLING pw TRANSITION BUSHING (IPS x CTS) Size (mm) 15 x 15 20 x 20 25 x 25 32 x 32 40 x 40 50 x 50 Size (In.) ½ ¾ 1 1¼ 1½ 2 IPS IPS IPS IPS IPS IPS x ½ CTS x ¾ CTS x 1 CTS x 1¼ CTS x 1½ CTS x 2 CTS PartNo. M M M M M M 2902 2903 2904 2905 2906 2908 Size (mm) Size (In.) 20 x 20 25 x 25 ¾ IPS x ¾ CTS 1 IPS x 1 CTS PartNo. T 4342 M 4111 Quantity (Case) 10 / 100 50 / --- Quantity (Case) 1500 1000 200 150 80 50 COUPLING Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 PartNo. M M M M M M 4120 4340 4100 4105 4106 4200 Quantity (Case) 1200 600 600 300 200 50 REDUCER COUPLING Size (mm) 20 x 15 25 x 15 25 x 20 32 x 15 32 x 20 32 x 25 40 x 15 40 x 20 40 x 25 40 x 32 50 x 15 50 x 20 50 x 25 50 x 32 50 x40 Size (In.) ¾ 1 1 1¼ 1¼ 1¼ 1½ 1½ 1½ 1½ 2 2 2 2 2 x x x x x x x x x x x x x x x ½ ½ ¾ ½* ¾* 1 ½* ¾ 1 1¼ ½ ¾* 1 1¼ 1½ PartNo. M 4341 M 4420 M 4134 M 4520 M 4530 M 4540 M 4620 M 4630 M 4640 M 4650 M 4820 M 4830 M 4840 M 4850 M 4860 Quantity (Case) 800 500 400 200 75 75 50 40 30 30 Only Those products bearing the NSF Mark are certified. REDUCER BUSHING Size (mm) 20 x 15 25 x 15 25 x 20 32 x 15 32 x 20 32 x 25 40 x 15 40 x 20 40 x 25 40 x 32 50 x 15 50 x 20 50 x 25 50 x 32 50 x 40 Size (In.) ¾ 1 1 1¼ 1¼ 1¼ 1½ 1½ 1½ 1½ 2 2 2 2 2 11 * Reducer fittings are professionally assembled using Flowguard fittings and bushings. Quantity as per order. NOTE : Fabricated reducer fittings are not eligible for return to the manufacturer. x x x x x x x x x x x x x x x ½ ½ ¾ ½ ¾ 1 ½ ¾ 1 1¼ ½ ¾ 1 1¼ 1½ PartNo. Quantity (Case) M 2032 M 2102 M 2103 M 2112 M 2113 M 2114 M 2122 M 2123 M 2124 M 2125 M 2202 M 2203 M 2204 M 2205 M 2206 1000 600 600 300 300 300 200 200 200 200 100 150 100 100 100 CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846 pw TEE Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 Part No. M M M M M M 7120 7340 7100 7105 7106 7200 Quantity (Case) 600 500 300 150 80 40 ELBOW 45° Size (mm) Size (In.) PartNo. 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 M M M M M M 5123 N 5343 N 5103 N 5153 N 5163 N 5203 N ELBOW 90° Size (mm) Size (In.) PartNo. 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 M M M M M M 5120 N 5340 N 5100 N 5105 N 5106 N 5200 N Quantity (Case) 1000 800 400 200 120 50 Quantity (Case) 500 200 250 60 40 15 REDUCER TEE REDUCER ELBOW 90° Size (mm) Size (In.) Part No. Quantity (Case) 20 x 15 25 x 15 25 x 20 32 x 15 32 x 25 50 x 25 ¾ x½ 1 x ½* 1 x ¾* 1¼ x ½ * 1¼ x 1 * 2 x1 * M 5341 N M 5151 M 5102 M 5141 M 5143 M 5241 500 As required As required As required As required As required Size (mm) Size (In.) Part No. Quantity (Case) 15 x 15 x 20 20 x 15 20 x 15 x 20 20 x 15 x 15 25 x 25 x 20 40 x 40 x 25 50 x 50 x 25 32 x 15 32 x 20 32 x 25 50 x 15 25 x 15 40 x 15 40 x 20 40 x 32 50 x 20 50 x 32 50 x 40 ½x½x¾ * ¾x½ ¾x½x¾ * ¾x½x½ * 1x1x¾ 1½ x 1½ x 1 2x2x1 1¼ x ½ 1¼ x ¾ 1¼ x 1 2x½ 1x½ 1½ x ½ 1½ x ¾ 1½ x 1¼ 2x¾ 2 x 1¼ 2 x 1½ M 7223 M 7341 M 7343 M 7342 M 7134 M 7161 M 7201 M 7552 M 7553 M 7554 M 7882 M 7442 M 7159 M 7123 M 7162 M 7883 M 7885 M 7886 As required 300 As required As required 75 30 15 100 100 80 30 300 70 60 60 35 30 25 Only those products bearing the NSF Mark are certified. 12 * Reducer fittings are professionally assembled using Flowguard fittings and bushings. Quantity as per order. NOTE : Fabricated reducer fittings are not eligible for return to the manufacturer. Application In Hospitals CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846 FEMALE ADAPTER (CPVC Threads) pw MALE ADAPTER (CPVC Threads) Size (mm) Size (In.) 15 20 25 32 40 50 20 x 15 ½ ¾ 1 1¼ 1½ 2 ¾ Soc x ½ MIP PartNo. M M M M M M M 6120 6340 6100 6105 B 6106 B 6200 B 6320 Quantity (Case) 600 600 300 150 100 50 500 Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 PartNo. M M M M M M 6122 6342 6101 6205 6206 6201 Quantity (Case) 800 400 200 150 100 50 TANK ADAPTER CROSS Size (mm) Size (In.) PartNo. Quantity (Case) 15 20 ½ ¾ M 8120 M 8340 200 100 PartNo. Quantity (Case) Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 PartNo. M M M M M M 9502 9503 9504 9505 9506 9508 Quantity (Case) 80 60 40 30 20 15 UNION Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 M M M M M M 2502 2503 2504 2505 2506 2508 200 150 100 80 50 30 Only Those products bearing the NSF Mark are certified. 13 CAP Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 PartNo. M M M M M M 3120 3340 3100 3105 3106 3200 Quantity (Case) 1000 500 200 100 80 40 FEMALE ADAPTER (Brass Threads) Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 PartNo. M M M M M M CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846 Quantity (Case) 6123 6343 6103 6113 6153 6203 200 150 50 25 25 15 BRASS FPT TEE Size (mm) Size (In.) 15 x 15 x 15 20 x 20 x 15 20 x 20 x 20 25 x 25 x 15 32 x 32 x 32 32 x 32 x 15 ½ x ½ x½ ¾ x ¾ x½ ¾ x ¾ x¾ 1 x 1 x½ 1¼ x 1¼ x 1¼ 1¼ x 1¼ x ½ PartNo. M M M M M M 7722 7732 7733 7742 7755 7752 Quantity (Case) 200 100 125 75 30 40 BRASS COUPLING Size (mm) Size (In.) PartNo. Quantity (Case) 20 x 15 25 x 15 ¾ X½ 1X½ M 4732 M 4742 200 100 MALE ADAPTER (Brass Threads) BRASS FPT 90° ELBOW Size (mm) Size (In.) PartNo. 15 x 15 20 x 15 20 x 20 25 x 15 25 x 25 32 x 32 ½ x ¾ x ¾ x 1 x 1 x 1¼x M M M M M M ½ ½ ¾ ½ 1 1¼ 5702 N 5730 N 5703 N 5740 N 5704 N 5705 N Quantity (Case) Size (mm) Size (In.) 15 20 25 32 40 50 20 x 15 ½ ¾ 1 1¼ 1½ 2 ¾ Soc x ½ MIP PartNo. M M M M M M M 6023 6033 6043 6053 6063 6083 6323 Quantity (Case) 200 100 50 25 25 15 150 200 150 100 100 50 30 14 Application In Corporates CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE AS PER ASTM D-2846 CONCEALED VALVE (CHROME PLATED) Size (mm) Size (In.) PartNo. Quantity (Case) 15 20 ½ ¾ M 1822-005 M 1822-007 01 01 CONCEALED VALVE (WHEEL TYPE) Size (mm) Size (In.) PartNo. Quantity (Case) 15 20 ½ ¾ M 1822-005W M 1822-007W 01 01 STEP OVER BEND FABRICATED BAND Size (mm) Size (In.) PartNo. Quantity (case) 20 25 32 40 50 ¾ 1 1¼ 1½ 2 M 5340 FB M 5100 FB M 5105 FB M 5106 FB M 5340 FB 130 75 45 25 14 Size (mm) Size (In.) PartNo. Quantity (Case) 15 20 25 ½ ¾ 1 F12 - SOB F34 - SOB F1 - SOB 150 200 150 SSR ELBOW BALL VALVES (CTS Sockets) 15 Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 PartNo. M M M M M M 1922 - 005 1922 - 007 1922 - 010 1922 - 012 1922 - 015 1922 - 020 Quantity (Case) 80 120 50 40 30 15 Size (mm) Size (In.) PartNo. Quantity (Case) 15 x 15 20 x 15 ½x½ ¾x½ M 5120 SR N M 5341 SR N 200 50 CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 40 FITTINGS AS PER ASTM F- 438 TEE - Soc Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 2½ 3 4 M 401 - 025C M 401 - 030C M 401 - 040C 12 08 04 90° ELBOW- Soc CAP - Soc Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 2½ 3 4 M 447 - 025C M 447 - 030C M 447 - 040C 10 10 10 Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 2½ 3 4 M 406 - 025C M 406 - 030C M 406 - 040C 15 10 06 REDUCER BUSHING (Flush Style) COUPLING - Soc Size (mm) 65 x 32 65 x 40 65 x 50 80 x 40 80 x 50 80 x 65 100 x 50 100 x 65 100 x 80 Size (In.) 2½ 2½ 2½ 3 3 3 4 4 4 x 1¼ x 1½ x2 x 1½ x2 x 2½ x2 x 2½ x3 PartNo. M M M M M M M M M 437 - 290C 437 - 291C 437 - 292C 437 - 337C 437 - 338C 437 - 339C 437 - 420C 437 - 421C 437 - 422C Quantity (Case) 25 25 25 20 20 20 10 10 10 Size (mm) Size (In.) 65 80 100 2½ 3 4 PartNo. M 429 - 025C M 429 - 030C M 429 - 040C Quantity (Case) 20 15 08 16 Application In Hotels CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 80 FITTINGS AS PER ASTM - 439 REDUCING TEE - Soc TEE - Soc Size (mm) Size (In.) PartNo. Quantity (Case) 100 x 50 100 x 80 150 x 100 200 x 150 250 x 200 300 x 250 * 4x 2 * 4x 3 * 6x 4 * 8x 6 *10 x 8 *12 x 10 801 - 420C 801 - 422C 801 - 532C 801 - 585C 801 - 628C 801 - 670C As required As required As required As required As required As required Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 150 200 250 300 2½ 3 4 6 8 * 10 * 12 M 801 - 025C M 801 - 030C M 801 - 040C M 801 - 060C M 801 - 080C 801 - 100C 801 - 120C 12 07 04 02 01 01 01 MALE ADAPTER Soc x MBSP REDUCER BUSHING (Flush Style) Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 2½ 3 4 M 836 - 025C M 836 - 030C M 836 - 040C 30 20 15 UNION Soc With EPDM O-Ring Seal Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 150 *2½ *3 *4 *6 897 - 025C 897 - 030C 897 - 040C 897 - 060C 05 05 05 03 17 *Trading Item Size (mm) 100 x 50 65 x 50 80 x 50 100 x 80 150 x 100 200 x 150 250 x 200 300 x 250 100 x 65 80 x 65 Size (In.) 4 2½ 3 4 6 8 * 10 * 12 4 3 x 2 x 2 x 2 x 3 x 4 x 6 x 8 x 10 x 2½ x 2½ PartNo. Quantity (Case) M 837 - 420C M 837 - 292C M 837 - 338C M 837 - 422C M 837 - 532C M 837 - 585C 837 - 628C 837 - 670C M 837 - 421C M 837 - 339C 20 50 35 20 06 03 01 01 10 35 FEMALE ADAPTER Soc x FBSP Size (mm) Size (In.) 65 80 100 2½ 3 4 PartNo. M 835 - 025C M 835 - 030C M 835 - 040C Quantity (Case) 30 20 15 CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 80 FITTINGS AS PER ASTM F-439 CAP Soc Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 150 200 250 300 * 2½ * 3 * 4 * 6 * 8 *10 *12 847 - 025C 847 - 030C 847 - 040C 847 - 060C 847 - 080C 847 - 100CF 847 - 120CF 10 10 06 03 01 01 01 COUPLING - Soc Size (mm) Size (In.) 65 80 100 150 200 250 300 2½ 3 4 6 8 * 10 * 12 PartNo. M M M M M 829 - 025C 829 - 030C 829 - 040C 829 - 060C 829 - 080C 829 - 100C 829 - 120C Quantity (Case) 20 15 12 02 01 01 01 REDUCER COUPLING - Soc Size (mm) 80 x 100 x 100 x 150 x 200 x 250 x 300 x 62 x 80 x 100 x 50 50 80 100 150 200 250 50 65 65 Size (In.) PartNo. Quantity (Case) 3 x 2 * 4 x 2 4 x 3 * 6 x 4 * 8 x 6 *10 x 8 *12 x 10 2½ x 2 3 x 2½ 4 x 2½ M 829 - 338 C 829 - 420 C M 829 - 422 C 829 - 532C 829 - 585C 829 - 628CF 829 - 670CF M 849 - 292 C M 829 - 339 C 829 - 421 25 As required 15 As required As required As required As required 40 25 As required 90° ELBOW Soc Size (mm) Size (In.) 65 80 100 150 200 250 300 2½ 3 4 6 8 * 10 * 12 PartNo. M M M M M 806 - 025C 806 - 030C 806 - 040C 806 - 060C 806 - 080C 806 - 100C 806 - 120C Quantity (Case) 15 10 05 02 01 01 01 45° ELBOW Soc Size (mm) 65 80 100 150 200 250 300 Size (In.) * 2½ * 3 4 * 6 * 8 *10 *12 PartNo. Quantity (Case) 817 - 025C 817 - 030C M 817 - 040C 817 - 060C 817 - 080C 817 - 100C 817 - 120C 05 05 05 02 01 01 01 18 *Trading Item Application In Residential Projects CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS SCH - 80 FITTINGS AS PER ASTM F-439 VANSTONE FLANGE Spig BLIND FLANGE Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 150 200 250 300 * 2½ 3 4 * 6 * 8 *10 *12 853 - 025C M 853 - 030C M 853 - 040C 853 - 060C 853 - 080C 853 - 100C 853 - 120C 05 20 12 03 01 01 01 Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 150 200 250 300 * 2½ 3 4 * 6 * 8 * 10 * 12 856 - 025C M 856 - 030C M 856 - 040C 856 - 060C 856 - 080C 856 - 100C 856 - 120C 05 10 06 03 01 01 01 FLANGE Soc FLANGE HUB Spig Size (mm) Size (In.) PartNo. Quantity (Case) 80 100 3 4 M 856 - 030-2C M 856 - 040-2C 05 05 Size (mm) Size (In.) PartNo. 65 80 100 150 200 250 300 * 2½ 3 4 * 6 * 8 *10 *12 851- 025C M 851 - 030C M 851 - 040C 851 - 060C 851 - 080C 851 - 100C 851 - 120C Quantity (Case) 05 15 12 03 01 01 01 VANSTONE FLANGE - Soc Size (mm) Size (In.) PartNo. Quantity (Case) 65 80 100 150 200 250 300 2½ 3 4 6 8 *10 *12 M 854 - 025 C M 854 - 030 C M 854 - 040 C M 854 - 060 C M 854 - 080 C 854 - 100C 854 - 120C 15 12 08 03 01 As required As required 19 *Trading Item FLANGE HUB Soc Size (mm) Size (In.) 65 80 100 150 200 2½ 3 4 6 8 M M M M M PartNo. Quantity (Case) 854 - 025 - 2C 854 - 030 - 2C 854 - 040 - 2C 854 - 060 - 2C 854 - 080 - 2C As Required As Required As Required As Required As Required CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS COPPER - TUBE SIZE Class 1 - PIPE SDR-11 ® pw IS 15778 CM/L-3673470 Class 2 - PIPE SDR -13.5 IS 15778 CM/L-3673470 IPS - IRON PIPE SIZE AS PER ASTM F-441 PIPE SCHEDULE 40 PIPE SCHEDULE 80 Only Those products bearing the NSF Mark are certified. 20 Application In Educational Institutes CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS FLOWGUARD 1-STEP ADHESIVE SOLUTION (YELLOW) Reduced VOC Emissions, NSF Listed ASTM F-493 N.B. For sizes 15 mm (½") to 50 mm (2") Size PartNo. Quantity (case) 50 ml 118 ml 237 ml 473 ml 946 ml MTINS - 50 MTINS - 118 MTINS - 237 MTINS - 473 MTINS - 946 48 24 24 12 12 CPVC 724 N.B. For sizes 65 mm (2½") and above Size PartNo. Quantity (case) 473 ml 946 ml IPS - 473 IPS - 946 12 12 PRIMER P70 N.B. Must use primer for 65 mm (2½") & above 21 Size PartNo. Quantity (case) 118 ML 237 ML 473 ML 946 ML EZ - 223 EZ - 222 EZ - 221 EZ - 220 24 24 12 12 CPVC PIPE & FITTINGS FOR HOT & COLD WATER DISTRIBUTION SYSTEMS PLASTIC STRAP Size (mm) Size (In.) Part No. Quantity (case) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 M 9120 M 9340 M 9100 M 9105 M 9106 M 9200 2500 2000 1200 600 500 300 METAL STRAP Size (mm) Size (In.) 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 Part No. 9120 9340 9100 9105 9106 9200 M M M M M M Quantity (case) 100 100 100 50 50 50 END PLUG Size (mm) Size (In.) Part No. Quantity (case) 15 ½ M PLUG -12 I 300 ELBOW HOLDER METAL STRAP (N) Size (mm) Size (In.) Part No. Quantity (case) Size (mm) Size (In.) 15 x 15 20 x 15 ½x½ ¾x½ MH 12I MH - 12-34 N 200 200 15 20 25 32 40 50 ½ ¾ 1 1¼ 1½ 2 Size(mm) (case) Size (In.) PartNo. 15 20 ½ ¾ F12-PPK F34-PPK PUNCHARE KIT Part No. 9120 9340 9100 9105 9106 9200 MN MN MN MN MN MN Quantity (case) 100 100 100 50 50 50 TEE HOLDER Quantity Size (mm) Size (In.) Part No. Quantity (case) As required As required 20 x 15 ¾x½ M-T-H -34-12N 200 22 TECHNICAL DETAILS Outside Diameters and Wall Thicknesses For CPVC 4120, SDR 11 Plastic Pipe As Per ASTM D-2846 Nominal Size Outside Diameter, in. (mm) (in.) ½* ¾ 1 1¼ 1½ 2 Average 0.625 (15.9) 0.875 (22.2) 1.125 (28.6) 1.375 (34.9) 1.625 (41.3) 2.125 (54.0) (mm) (15) (20) (25) (32) (40) (50) Tolerance ± 0.003 (0.08) ± 0.003 (0.08) ± 0.003 (0.08) ± 0.003 (0.08) ± 0.004 (0.10) ± 0.004 (0.10) Pressure Rating.PSI (Kg/Cm2) Wall Thickness, in. (mm) Minimum 0.068 (1.73) 0.080 (2.03) 0.102 (2.59) 0.125 (3.18) 0.148 (3.76) 0.193 (4.90) Tolerance + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.023 (0.58) 73.4°F 400 400 400 400 400 400 (23°C) (28.1) (28.1) (28.1) (28.1) (28.1) (28.1) 180°F 100 100 100 100 100 100 (82°C) (7.0) (7.0) (7.0) (7.0) (7.0) (7.0) * For ½" wall thickness minimum is not a function of SDR. Nominal Size (in.) ½* ¾ 1 1¼ 1½ 2 (mm) (15) (20) (25) (32) (40) (50) Outside Diameters and Wall Thicknesses For CPVC 4120, SDR 13.5 Plastic Pipe Pressure Rating.PSI (Kg/Cm2) Wall Thickness, in. (mm) Outside Diameter, in.(mm) Average 0.625 (15.9) 0.875 (22.2) 1.125 (28.6) 1.375 (34.9) 1.625 (41.3) 2.125 (54.0) Tolerance ± 0.003 (0.08) ± 0.003 (0.08) ± 0.003 (0.08) ± 0.003 (0.08) ± 0.004 (0.10) ± 0.004 (0.10) Minimum 0.055 (1.40) 0.065 (1.65) 0.083 (2.12) 0.102 (2.59) 0.120 (3.06) 0.157 (4.00) Tolerance + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.020 (0.51) + 0.023 (0.58) 73.4°F 320 320 320 320 320 320 (23°C) (22.5) (22.5) (22.5) (22.5) (22.5) (22.5) 180°F 80 80 80 80 80 80 (82°C) (5.6) (5.6) (5.6) (5.6) (5.6) (5.6) * For ½" wall thickness minimum is not a function of SDR. Outside Diameters, Wall Thickness & Pressure Rating For CPVC 4120, Schedule 40 Piping System As per ASTM F 441 Nominal Size (in.) (mm) 2½ (65) 3 (80) 4 (100) Outside Diameter, in. (mm) Average Tolerance 2.875 (73.0) ± 0.007 (0.18) 3.500 (88.9) ± 0.008 (0.20) 4.500 (114.3) ± 0.009 (0.23) I.D. Average 2.444 (62.07) 3.041 (77.26) 3.998 (101.55) Wall Thickness, in. (mm) Minimum Tolerance 0.203 (5.16) + 0.024 (0.61) 0.216 (5.49) + 0.026 (0.66) 0.237 (6.02) + 0.028 (0.71) Pipe - Pr. R. PSI (Kg/Cm2) Fitting - Pr. R. PSI (Kg/Cm2) 73.4°F (23°C) 73.4°F (23°C) 300 (21.10) 180 (12.65) 280 (18.28) 156 (10.96) 220 (15.47) 132 (09.28) Pr. R. = Pressure Rating Outside Diameters, Wall Thickness & Pressure Rating For CPVC 4120, Schedul 80 Piping System As per ASTM F 441 Pipe-Pr. R. Fitting-Pr. R. I.D. Nominal Size Wall Thickness, in. (mm) Outside Diameter, in. (mm) PSI (Kg/Cm2) PSI (Kg/Cm2) (in.) (mm) Average Tolerance Average Minimum Tolerance 73.4°F (23°C) 73.4°F (23°C) 2½ (65) 2.875 (73.0) ± 0.007 (0.18) 2.288 (58.14) 0.276 (7.01) + 0.033 (0.84) 420 (29.53) 252 (17.71) 3 (80) 3.500 (88.9) ± 0.008 (0.20) 2.864 (72.75) 0.300 (7.62) + 0.036 (0.91) 370 (26.01) 222 (15.60) 4 (100) 4.500 (114.3) ± 0.009 (0.23) 3.778 (95.97) 0.337 (8.56) + 0.040 (1.02) 320 (22.50) 192 (13.49) 6 (150) 6.625 (168.3) ±0.011 (0.28) 5.710 (145.04) 0.432 (10.97) + 0.052 (1.32) 280 (19.69) 168 (11.81) 8 (200) 8.625 (219.1) ±0.015 (0.38) 7.565 (192.15) 0.500 (12.70) + 0.060 (1.52) 250 (17.57) 150 (10.54) 10 (250) 10.750 (273.1) ±0.015 (0.38) 9.493 (241.12) 0.593 (15.06) + 0.071 (1.80) 230 (16.17) 138 (09.70) 12 (300) 12.750 (323.90) ±0.015 (0.38) 11.294 (286.87) 0.687 (17.45) + 0.082 (2.08) 230 (16.17) 138 (09.70) Pr. R. = Pressure Rating Temperature Derating Factors 90 100 120 140 Working Temperature (°F) 73-80 Working Temperature (°C) 23-25 32 38 49 60 Pipe Derating Factor 1.00 0.91 0.82 0.65 0.50 Valve Derating Factor 1.00 0.95 0.90 0.80 0.70 160 71 0.40 0.61 180 82 0.25 0.53 200 93 0.20 0.45 N.B. : For obtaining working pressure in system, multiply the maximum pressure with derating factor at the working temperature of system. * Valves, Unions & Speciality Products have different elevates temperature rating than pipe. 23 J 0 45 J Tapered Socket Dimensions For CPVC 4120, SDR 11, Plastic Pipe Fittings AS PER ASTM D2846 Nominal Size (in.) (mm) ½ ¾ 1 1¼ 1½ 2 (15) (20) (25) (32) (40) (50) Socket Entrance Diameter in.(mm) Socket Bottom Diameter in.(mm) Socket Length "A" Average "A" Tolerance "B" Average "B" Tolerance 0.633 (16.08) 0.884 (22.45) 1.135 (28.83) 1.386 (35.20) 1.640 (41.66) 2.141 (54.38) 0.619 0.870 1.121 1.372 1.622 2.123 ± 0.003 ± 0.003 ± 0.003 ± 0.003 ± 0.004 ± 0.004 (0.08) (0.08) (0.08) (0.08) (0.10) (0.10) (15.72) (22.10) (28.47) (34.85) (41.20) (53.92) ± 0.003 ± 0.003 ± 0.003 ± 0.003 ± 0.004 ± 0.004 (0.08) (0.08) (0.08) (0.08) (0.10) (0.10) Inside Diameter in (mm) "D" min "C" min. 0.500 0.700 0.900 1.100 1.300 1.700 (12.70) (17.78) (22.86) (27.94) (33.02) (43.18) 0.489 0.715 0.921 1.125 1.329 1.739 (12.42) (18.16) (23.39) (28.58) (33.76) (44.17) Wall Thickness in. (mm) Socket Socket Enterance Bottom "EA" min. "EB" min. "F" 0.068 0.080 0.102 0.125 0.148 0.193 (1.73) (2.03) (2.59) (3.18) (3.76) (4.90) 0.102 0.102 0.102 0.125 0.148 0.193 (2.59) (2.59) (2.59) (3.18) (3.76) (4.90) 0.128 0.128 0.128 0.156 0.185 0.241 J 450 J G G (3.25) (3.25) (3.25) (3.96) (4.70) (6.12) N AMERICAN NATIONAL STANDARD TAPER PIPE THREADS (NPT) ANSI STANDARD B1.20.1 ASTM STANDARD F 1498 Effective Thread Pitch of Nominal Size Threads Length Thread (mm) (in.) Per in. P L 15 20 25 32 40 50 65 80 100 ½ ¾ 1 1¼ 1½ 2 2½ 3 4 14 14 11½ 11½ 11½ 11½ 8 8 8 0.5337 0.5457 0.6828 0.7068 0.7235 0.7565 1.1375 1.2000 1.3000 ½ ¾ 1 1¼ 1½ 2 2½ 3 4 14 14 11 11 11 11 11 11 11 13.152 14.514 16.714 19.050 19.050 23.378 26.698 29.873 35.791 G Minimum Dimensions from Center to End of Socket (Laying Length) for CPVC 4120, SDR 11 Plastic Tubing Fittings* per ASTM D 2846 Nominal (G) Min. (J) Min. Size ½ 0.382 0.183 ¾ 0.507 0.235 1 0.633 0.287 1¼ 0.758 0.339 1½ 0.884 0.391 2 1.134 0.495 0.07143 0.07143 0.08696 0.08696 0.08696 0.08696 0.12500 0.12500 0.12500 BSP ISO 7/1 PARALLEL THREADS Effective Thread Pitch of Nominal Size Threads Length Thread (mm) (in.) Per in. P L 15 20 25 32 40 50 65 80 100 G 1.8143 1.8143 2.3091 2.3091 2.3091 2.3091 2.3091 2.3091 2.3091 NPT (N) Min. 0.102 0.102 0.102 0.102 0.102 0.102 BSPT BASIC SOCKET DIMENSIONS SCHEDULE 40 CPVC FITTINGS AS PER ASTM F 438 SCHEDULE 80 CPVC FITTINGS AS PER ASTM F 439 Socket Length Diameter (in.) Nominal Size Socket Socket Minimum C (in.) Bottom (mm) (in.) Entrance Tolerance SCH 40 SCH 80 A B 65 80 100 150 200 250 300 2½ 3 4 6 8 10 12 2.889 3.516 4.518 6.647 8.655 10.780 12.780 2.868 3.492 4.491 6.614 8.610 10.735 12.735 ±0.007 ±0.008 ±0.009 ±0.011 ±0.015 ±0.015 ±0.015 1.750 1.875 2.000 3.000 4.000 5.000 6.000 1.750 1.875 2.250 3.000 4.000 5.000 6.000 24 FLUID HANDLING CHARACTERISTIC OF ASTRAL FLOWGUARD PIPE Linear Fluid Flow Velocity The linear velocity of a flowing fluid in a pipe is calculated from : 0.4085g d2 Where V = Linear fluid flow velocity in feet per second g = Flow rate in gallons per minute d = Inside diameter of pipe in inches V = The values in the following tables are based on this formula. These values are accurate for all fluids. Linear fluids flows velocity in a system should generally be limited to 5 ft/s, particularly for pipe size 6” and grater. Following this guideline will minimize risk of hydraulic shock damage due to water hammer surge pressures. Friction Loss in Pipes A great advantage that Flowguard Pipe enjoys over its metallic competitors is a smooth inner surface which is resistant to scaling and fouling. This means that friction pressure losses in the fluid flow are minimized from the beginning and do not significantly increase as the system ages, as can be the case with metal pipes subject to scaling. The Hazen-Willims formula is the generally accepted method of calculating friction head losses in piping systems. The values in the following fluid tables are based on this formula and a surface roughness constants for other piping materials are given beside : 1.852 ( ) 100 f =0.2083 X C where f d g c = = = = Friction head in feet of water per 100 feet of pipe Inside diameter of pipe in inches Flow rate in gallons per minute pipe surface roughness constant Constant (C) 150 130-140 125 120 60 - 80 g1.852 d4.8655 Type of Pipe - CPVC pipe, new-40 years old steel / cast iron pipe, new steel pipe, old cast iron, 4 - 12 years old galvanized steel cast iron, 13 - 20 years old cast iron, worn / pitted Friction Loss in Fittings Friction losses through fittings are calculated from the equivalent length of straigth pipe which would produce the same friction loss in the fluid. The equivalent lengths of pipe for common fittings are given here. 25 Nominal Size(mm) ½ ¾ 1 1¼ 1½ 2 2½ 3 4 6 8 10 12 900 Standard Elbow 1.55 2.06 2.62 3.45 4.03 5.17 6.10 7.60 10.00 15.10 19.90 24.90 29.70 450 Standard Elbow 0.83 1.10 1.40 1.84 2.15 2.76 3.30 4.10 5.30 8.00 10.60 13.30 15.90 Standard Standard TEE TEE Run Flow Branch Flow 1.04 3.11 1.37 4.12 1.75 5.25 2.30 6.90 2.68 8.05 3.45 10.30 4.10 12.20 5.10 15.20 6.70 20.00 10.10 30.20 13.20 39.70 16.60 49.90 19.80 59.40 Water Hammer Surge Pressure Whenever the flow rate of fluid in a pipe is change, there is a surge in pressure known as water hammer, The longer the line and the faster the fluid is moving, the greater the hydraulic shock will be. Water hammer may be caused by opening or closing a valve, starting or stopping a pump, or the movement of entrapped air through the pipe. The maximum water hammer surge pressure may be calculated from : ½ p∆V P 1 + d Pwh = gc K bE gc where Pwh = Maximum surge pressure, psi p = Fluid density ∆V = Change in fluid velocity gc = Gravitational constant K = Bulk modulus of elasticity of fluid b = Pipe wall thickness E = Pipe material bulk modulus of elasticity d = Pipe inside diameter [ ] The value in the following tables are based on this formula at 730F and the assumption that water flowing at a given rate of gallons per minute is suddenly completely stopped. At 180°F, the surge pressure is approximately 15% less. The value for fluids other then water may be by multiplying by the square root of the fluid’s specific gravity. THE WATER HAMMER SURGE PRESSURE PLUS THE SYSTEM OPERATING PRESSURE SHOULD NOT EXCEED 1.5 TIMES THE RECOMMENDED WORKING SEPARATE RATING OF THE SYSTEM. In order to minimize hydraulic shock due to water hammer, linear fluid flow velocity should generally be limited to 5ft/s, particularly for pipe size of 6” or longer. Velocity at system start-up should be limited to 1 ft/s during filling until it is certain that all air has been brought up to operating conditions. Air should not be allowed to draw in air. Where necessary, extra protective equipment may be used to prevent water hammer damage, shock absorbers, surge arrestors and vacuum air relief valves. 3.19 11.53 24.43 41.62 62.91 88.18 1.71 3.42 5.16 6.83 8.54 10.25 Gallons Per Minut 2 3 4 5 6 Pressure Loss PSI Per 100 Ft. Head Loss Feet of Water Per 100 Ft. 5.00 35.76 75.78 129.11 7.99 11.99 15.98 98.45 15 20 40.11 51.37 63.89 77.66 92.65 9.68 11.30 12.91 14.52 16.14 17.75 34.60 46.03 79.82 106.19 14.45 16.86 30 35 40 45 50 55 17.89 22.91 28.50 34.64 52.37 9.46 10.61 12.16 13.51 16.89 80 90 100 125 64.37 16.19 70 13.45 8.10 48.38 13.88 60 11.45 7.43 41.18 12.72 9.60 6.75 34.52 11.56 40.16 33.66 27.70 27.90 20.97 17.85 14.96 12.31 7.89 4.96 3.73 2.66 1.76 1.03 0.49 0.13 6.08 28.40 10.41 4.73 4.05 3.38 2.70 2.03 1.35 0.68 6.35 22.27 9.90 7.73 5.81 4.15 2.74 1.61 0.76 0.21 2 in. 5.40 22.83 13.40 9.56 6.33 3.71 1.75 0.49 9.25 6.94 5.78 4.63 3.47 2.31 1.16 17.83 17.39 13.07 9.33 6.17 3.62 1.71 0.47 8.09 30.15 21.51 8.07 24.69 56.94 14.23 8.35 3.94 1.09 12.04 4.84 3.23 1.61 25 9.58 4.52 3.72 2.99 2.34 1.76 1.25 6.46 22.11 10.43 8.59 6.90 5.39 4.05 16.33 7.22 4.82 4.33 3.85 3.37 2.89 37.67 55.97 32.85 15.50 12.76 10.26 8.01 6.02 0.83 0.49 9.63 227.11 17.08 10 29.42 7.19 81.00 186.85 15.38 23.66 6.39 9 18.47 5.59 65.13 8 50.86 117.32 150.23 11.96 13.67 7 13.89 4.79 38.23 2.89 1.91 0.23 Velocity Feet Per Second 2.41 1.93 1.12 0.53 Pressure Loss PSI Per 100 Ft. 4.29 2.84 1.44 0.96 0.06 Velocity Feet Per Second 9.91 6.55 1.67 0.79 0.15 Pressure Loss PSI Per 100 Ft. 4.00 3.20 3.85 1.82 0.48 1 1 /2 in. Velocity Feet Per Second 27.27 18.04 2.40 1.60 Pressure Loss PSI Per 100 Ft. 0.22 Velocity Feet Per Second 0.50 Pressure Loss PSI Per 100 Ft. 10.59 Velocity Feet Per Second 0.80 Head Loss Feet of Water Per 100 Ft. 1.38 Head Loss Feet of Water Per 100 Ft. 1 1 /4 in. Head Loss Feet of Water Per 100 Ft. 1 in. Head Loss Feet of Water Per 100 Ft. 3 /4 in. Head Loss Feet of Water Per 100 Ft. 1 /2 in. Velocity Feet Per Second 1 (Friction head and Friction Loss are per 100 feet of pipe) NOTICE : Flow velocity should not exceed 5 feet per second. Velocities in excess of 5 feet per second may result in system failure and property damage. Friction Loss and Flow velocity for SDR 11 CTC CPVC Thermoplastic Pipe 22.70 15.02 12.35 9.93 7.76 5.83 4.96 4.16 3.42 2.75 2.15 1.62 1.15 0.76 0.45 0.21 0.06 Pressure Loss PSI Per 100 Ft. 26 27 4" CAUTION : Flow velocity should not exceed 5 feed per second. • CPVC pipe can not be used for compressed air service. 3" (Independent variables : Gallons per minute and nominal pipe size O.D. Dependent variables : Velocity, Friction head and pressure drop per 100 feet of pipe, interior smooth.) Carrying Capacity and Friction Loss for Schedule 40 Thermoplastic Pipe 2.5" 28 4 in. 6 in. 8 in. CAUTION : Flow velocity should not exceed 5 feed per second. • CPVC pipe can not be used for compressed air service. 3 in. (Independent variables : Gallons per minute and nominal pipe size O.D. Dependent variables : Velocity, Friction head and pressure drop per 100 feet of pipe, interior smooth.) Carrying Capacity and Friction Loss for Schedule 80 Thermoplastic Pipe 10 in. 12 in. 2 1/2 in. Fixed Point op Lo Guidehanger THERMAL EXPANSION AND CONTRACTION Like all piping material, Flowguard CPVC expand when heated and contract when cooled. CPVC piping (regardless of pipe diameter) will expand about 1 inch per 50 feet of length when subjected to a 50° F temperature increase, therefore, allowances must be made for this resulting movement. However, laboratory testing and installation experience have demonstrated that the practical issues are much smaller than the coefficient of thermal expansion would suggest. The stresses developed in CPVC pipe are generally much smaller than those developed in metal pipe for equal temperature changes because of the difference in elastic modulus. Required loops are smaller than those recommended by the Copper Development Association for copper systems. Expansion is mainly a concern in hot water lines, Generally, thermal expansion can be accommodated with changes in direction. However, a long straight run may require an offset or loop. Only one expansion loop, properly sized is required in any single straight run, regardless of its total length. If more convenient, two or more smaller expansion loops, properly sized, can be utilized in a single run of pipe to accommodate the thermal movement. Be sure to hang pipe with smooth straps that will not restrict movement. For convenience, loop (or offset) length have been calculated for different pipe sizes and different run length with a temperature increase (DT) of about 80°F. The results, shown in Tables A and B, are presented simply as a handy guide for quick and easy determinations of acceptable loop length for the approximate conditions. Loop length for other temperatures and run length can be calculated utilizing the following equations : Expansion Loop Formula L= Where: L = E = S = D = ∆L = 3 ED (∆ L ) 2S Loop Length (in.) Modululs of elasticity at maximum temperature (psi) Working stress at maximum temperature (psi) Outside diameter of pipe (in.) Change in length due to change in temperature (in.) Thermal Expansion Formula ∆L = Lp C ∆T Where: ∆L = Lp = C = = ∆T = 29 Change in length due to change temperature (in.) Length of pipe (in.) Coefficient of thermal expansion (in. / in. /°F) 3.4 x 10-5in. / in. /°F for CPVC Change in temperature (°F) OFFSET LOOP Modulus of Elasticity and Working Stress for CPVC Temperature Modulus,E(psi) Stress, S(psi) °F (°C) 73 (27) 423,000 2000 90 (32) 403,000 1800 110 (43) 371,000 1500 120 (49) 355,000 1300 140 (60) 323,000 1000 160 (71) 291,000 750 180 (82) 269,000 500 4 X = 2L/5 Y = L/5 2 =X 5 2 6' MIN Y= 6' MIN 5 4 TABLE A Flowguard CPVC pipe CTS PIPES (ASTM D 2846) Calculated Loop (Offset) Length with Change of Direction ∆ T of approx. 80°F in inches Long Run of Pipe Nominal Pipe size mm in. 15 ½ 20 ¾ 25 1 32 1¼ 40 1½ 50 2 = Hanger or Guide = Restraint Length of Run in feet 40 22 26 29 32 35 40 60 27 32 36 40 43 49 80 31 36 41 46 50 57 100 34 41 46 51 56 64 Do not butt-up against fixed structure (joist, stud or wall) CPVC pipeline for Hot Water TABLE B 6' MIN 2 5 3rd Floor Flowguard CPVC IPS PIPES (ASTM F 441) Calculated Loop (Offset) Length with 5 Fixed Point 6' MIN 2nd Floor Loop ∆ T of approx. 80°F in inches 1st Floor Guide/ hanger Ground Floor 30 HORIZONTAL & VERTICAL SUPPORTS Horizontal & Vertical runs of Astral FlowGuard Pipe should be supported by pipe clamps or by hangers located on the horizontal connection close to the Riser, Hangers should not have rough or sharp edges, which come in contact with the pipe. Band Hanger Anchor Strap Pipe Clamp U-Bolt 21°C (70°F) Nominal Pipe Size mm 15 20 25 32 40 50 65 75 100 150 200 250 300 in. Ft. ½ ¾ 1 1¼ 1½ 2 2½ 3 4 6 8 10 12 (cm) 5.5 5.5 6.0 6.5 7.0 7.0 8.0 8.0 9.0 10.0 11.0 11.5 12.5 Ft. (167.70) (167.70) (182.88) (198.12) (213.36) (213.36) (244.00) (244.00) (274.32) (304.80) (335.28) (350.52) (381.00) SPACING 49°C (120°F) (cm) 4.5 5.0 5.5 6.0 6.0 6.5 7.5 7.5 8.5 9.0 10.0 10.5 11.0 Ft. (137.16) (152.40) (167.70) (182.88) (182.88) (198.12) (228.60) (228.60) (259.08) (274.32) (304.80) (320.04) (335.28) 71°C (160°F) (cm) 3.0 3.0 3.5 3.5 3.5 4.0 4.5 4.5 5.0 5.5 6.0 6.5 7.5 82°C (180°F) Ft. (cm) (91.44) 2.5 (76.20) (91.44) 2.5 (76.20) (106.68) 3.5 (91.44) (106.68) 3.5 (106.68) (106.68) 3.5 (106.68) (121.92) 3.5 (106.68) (137.16) 4.0 (121.92) (137.16) 4.0 (121.92) (152.40) 4.5 (137.16) (167.07) 5.0 (152.40) (182.88) 5.5 (167.07) (198.12) 6.0 (182.88) (228.60) 6.5 (198.12) TRANSITION FITTINGS & JOINTS Special transition fittings or joints are used whenever CPVC piping is connected to a metal valve, fittings, or other appurtenance such as a filter, or to parts made of another plastic. These special transition fittings can have many forms. One common form is the true union with a metal end and a CPVC end held together with a plastic or metal gland nut and having an elastomeric seal between them. Other forms are the flanged joint, the grooved joint, insert molded metal in CPVC fittings, patented push-on type fittings and finally the CPVC female threaded adapter with an elastomeric seal at the bottom of the thread. The later fittings are designed so that they have no thread interference and rely entirely on the elastomeric seal for water tightness. They require only minimal torque to attain an adequate seal. Standard compression fittings which utilize brass of plastic ferrules can be used to assemble CPVC. However, Teflon® tape should be applied over the brass ferrule to compensate for the dissimilar thermal expansion rates of the brass and CPVC that could possibly otherwise result in a leak. Care should be taken not to over-torque the compression connection. Metal fittings with CPVC socket inserts are also available. The tubing is cemented directly into the socket in the same way as an all-CPVC fittings. Plastic O.H.T. The standard practice is to thread a male thread adapter into the female threaded part, such as a valve of stop, and then solvent cement to the CPVC pipe. However, when using the male thread adapter, there are two limitations that the installer must consider when deciding where and how to use it. First, the male thread adapter may develop a drip leak if the joint is subjected to too broad temperature range. And second, some thread sealants intended to minimize leak problems may chemically attack the CPVC and cause stress cracking of the adapter (see Thread Sealants section). The preferred method of transitioning between metal and CPVC plumbing component is to use an insert molded metal-in-CPVC fitting or true union with a metal and a CPVC end. A typical Hot and Cold Water Distribution system operating at 60-700C requires support for horizontal lines every 90cm for diameters of 32mm and below, and every 120cm on larger size. However, the following spacings are based on conservative engineering assumptions and can be used at water temperatures indicated. Vertical CPVC piping should be supported at each floor and should have a mid-story guide, unless thermal expansion design call for other provisions. Piping should not be anchored tightly by the supports, but secured in a manner to allow for a degree of movement caused by thermal expansion. Hangers of strapping with rough edges should not be used. Ball valve Tank connector Tap Female Transition Nipple or F.T.A. 31 Male Transition Nipple or M.T.A. Elbow Female Threaded UNDERGROUND INSTALLATION CPVC pipes and fittings can be installed underground. Since these piping systems are flexible systems, proper attention should be given to burial conditions. The stiffness of the piping system is affected by sidewall support, soil compaction, and the condition of the trench. Trench bottoms should be smooth and regular in either undisturbed soil or a layer of compacted backfill. Pipe must lie evenly on this surface throughout the entire length of its barrel. Excavation, bedding and backfill should be in accordance with the provision of the local Plumbing Code having jurisdiction. TRENCHING The following trenching and burial procedures should be used to protect the piping system. 1. The trench should be excavated to ensure the sides will be stable under all working conditions. 2. The trench should be wide enough to provide adequate room for the following : A. Joining the pipe in the trench. B. Snaking the pipe from side or side to compensate for expansion and contraction. C. Filling and compacting the side fills. The space between the pipe and trench wall must be wider than the compaction equipment used in the compaction of the back fill. Minimum width shall not be less than the greater of either the pipe outside diameter plus 16.inches or the pipe outside diameter times 1.25 plus 12 inches. Trench width may be different if approved by the design engineer. 3. The trench bottom should be smooth, free of rocks and debris, continuous, and provide uniform support. If ledge rock, hardpan or large boulders are encountered, the trench bottom should be padded with bedding of compacted granular material to a thickness of at least 4 inches. Foundation bedding should be installed as required by the engineer. 4. Trench depth is determined by the pipe’s service requirements. Plastic pipe should always be installed at least below the frost level. The minimum cover for lines subject to heavy overhead traffic is 24 inches. 5. A smooth trench bottom is necessary to support the pipe over its entire length on firm stable material. Blocking should not be used to change pipe grade or to intermittently support pipe over low sections in the trench. BEDDING AND BACKFILLING 1. Even though sub-soil conditions vary widely from place to place, the pipe backfill should be stable and provide protection for the pipe. 2. The pipe should be surrounded with a granular material which is easily worked around the sides of the pipe Backfilling should be performed in layer of 6 inch with each layer being sufficiently compacted to 85% to 95% compaction. 3. A mechanical tamper is recommended for compacting sand and gravel backfill which contain a significant proportion of fine grained material, such as silt and clay. If a tamper is not available, compacting should be done by hand. 4. The trench should be completely filled. The backfill should be placed and spread in fairly uniform layers to prevent any unfilled spaces or voids. 32 REQUIRMENT OF THARMALLY INSULATING CPVC PIPE CPVC has much lower thermal conductivity then metals used in piping systems (0.14W / mk for CPVC verus > 400 W / mk for copper). For this reason in most cases it is not necessary to thermally insulate CPVC piping. However the equation below can be used to calculat the approximate heat loss from CPVC pipes 1 meter length of pipe. Q= λ di + do II. e 2 [ ] . ∆Τ Where Q = Heat loss per meter of pipe, W/m λ = Thermal conductivity. [W/mk] for CPVC, λ = 0.14 w/mk e = Thickness of pipe, mm .068 II = 3, 1416 di = Inside diameter, mm ∆Τ = Temperature differential between inner and outer surface of pipe. This can be approximated to : T water. T ambient (K) Example : What is the heat loss/meter from a 20mm outside diameter CPVC pipe. wall thickness 2,3mm, with water flowing inside at 800C and an ambient air temperature of 250C? Q = 0.14 . 3,1416 2.3 [ ] 20 + 15.4 . (80-25) 2 = 186 W/m Equation (1) can be simplified for standard pipe dimensions to : Q =K ∆Τ Where K is a conductivity of CPVC and the pipe geometry in the previus example. do = 20mm, and e = 2.3mm K 33 = 0.14 . 3,1416 2.3 [ ] 20 + 15.4 . = 3.38 (W/mks) 2 HANDLING : The pipe should be handled with reasonable care. Because thermoplastic pipe is much lighter in weight than metal pipe, there is sometimes a tendency to throw it around. This should be avoided. The pipe should never be dragged or pushed from a truck bed. Pallets for pipe should be removed with a fork lift. Loose pipe can be rolled down timbers as long as the pieces do not fall on each other or on any hard or uneven surface. In all cases, severe contact with any sharp objects (rocks, angle irons, forks on forklifts, etc.) should be avoided. STORING : If possible, pipe should be stored inside. When this is not possible, the pipe should be stored on level ground which is dry and free from sharp objects. If different schedules of pipes are stacked together, the pipes with the thickest walls should be at the bottom. The pipes should be protected from the sun and be in an area with proper ventilation. This will lessen the effects of ultraviolet rays and help prevent heat built-up. If the pipes are stored in racks, it should be continuously supported along its length. If this is not possible, the spacing of the supports should not exceed three feet (3’). When storage temperatures are below 0°C (32°F), extra care should be taken when handling the pipe. This will help prevent any problems which could be caused by the slightly lower impact strength of PVC pipes at temperature below freezing. JOINING ASTRAL CPVC PIPES & FITTINGS Solvent cement set and cure times are a function of pipe size, temperature and relative humidity. Curing time is shorter for drier environments, smaller sizes and higher temperatures. It requires 10 to 20 minutes for perfect joint. SET AND CURE In order to make a proper and neat joint, measure the pipe length accurately and make a small mark. Ensure that the pipe and fittings are size compatible. You can easily cut with a wheel type plastic pipe cutter or hacksaw blade. Cutting tubing as squarely as possible provides optimal bonding area within a joint. 1 6 Burrs and filings can prevent proper contact between tube and fitting during assembly and should be removed from the outside and inside of the pipe. Debarking tool, pocket knife or file are suitable for this. A slight bevel on the end of the tubing will ease entry of the tubing into the fitting socket. CUTTING 2 DEBURRING / BEVELING 3 FITTING PREPARATION 5 Using a clean, dry rag, wipe dirt and moisture from the fitting sockets and tubing end. The tubing should make contact with the socket wall 1/3 to 2/3 of the way into the fitting socket. ASSEMBLY Immediately insert the tubing into the fitting socket, rotate the tube ¼ to ½ turn while inserting. This motion ensures and even distribution of cement within the joint. Properly align the fittings. Hold the assembly for approximately 10 seconds, allowing the joint to set-up. 4 SOLVENT CEMENT APPLICATION use only CPVC cement or an all - purpose cement conforming to ASTM F 493 or joint failure may result. When making a joint, apply a heavy, even coat of cement to the pipe end. Use the same applicator without additional cement to apply a thin coat inside the fitting socket. Too much cement can cause clogged water ways. Note : For sizes above 65 mm (2½") use IPS 70 primer before applying solvent cement. The purpose of a primer is to penetrate and soften the surfaces so they can stick together. The proper use of a primer ensures that the surfaces are prepared for fusion in a wide variety of weather conditions. 34 HOW TO USE SOLVENT CEMENT, PRIMER & CLEANER JOINT CURING : BEFORE BEGINNING : Recommended initial set times. 1. Temperature Range 15.5OC - 37.7OC 4.4OC - 15.5OC Pipe Size Pipe Size Pipe Size Pipe Size 1 1/4” 1 1/2” to 3” 4”to 8” 10” to 12” 15 mm 40 mm 100 mm 250 mm to to to to 32 mm 80 mm 200 mm 300 mm 15 min 30 min 1 hrs. 2 hrs. 1 hrs. 2 hrs. 4 hrs. 8 hrs. 1/2” to Recommended initial cure times. Temperature Range 15.5OC - 37.7OC 4.4OC - 15.5OC Pipe Size Pipe Size 1 1/4” 1 1/2” to 3” 15 mm 40 mm to to 32 mm 80 mm 6 hrs. 12 hrs. 12 hrs. 24 hrs. 1/2” to Pipe Size 4”to 8” 100 mm to 200 mm 24 hrs. 48 hrs. Pipe Size 10” to 12” 250 mm to 300 mm 48 hrs. 96 hrs. CHOOSING CEMENTS & PRIMERS : Solvent cements for Flowguard CPVC systems must conform to the requirements of ASTM F-493 or equivalent and should carry this identification on the can label. A primer or cleaner must be used on CPVC Primers for PVC pipe are acceptable for CPVC. The National Sanitation Foundation mark (NSF) or other potable water approval should also be located on the container. Certain code bodies require orange CPVC solvent cement and purple primer to facilitate identification by plumbing inspectors. However, unpigmented (clear) CPVC solvent cement and primer are available and accepted by various jurisdictions. If you decide to use clear products, we strongly recommend contracting the local plumbing inspector prior to beginning a job to determine if these clear cements and primers are acceptable. CPVC CEMENT’S SHELF LIFE : CPVC solvent cement are formulated to have a Shelf life of two years. Cans are usually marked with manufacturing dates. Good CPVC cement should have the consistency of syrup or honey with no undissolved materials. Ages cement will often change colour or begin to thicken and become gelatinous or jellylike. When this occurs, the cement must be thrown away. SOLVENT CEMENT FREEZING : Use the same precautions to protect CPVC solvent cement from freezing as you would with PVC cement. Once cement gels, it can not be recovered and should be discarded. 35 2. Verify the cement is the same as the pipes and fittings being used. Check the temperature where the cementing will take place. • • Cement take longer time to set up in cold weather. Be sure to allow extra time for curing. Do not try to speed up the cure by artificial means this could cause porosity and blisters in the cement film. Solvents evaporate faster in warm weather. Work quickly to avoid the cement setting up before the joint is assembled. Keep the cement as cool as possible. Try to stay out of direct sunlight.3. Keep the lid on cements, cleaner, and primers when not is use Evaporation of the solvent will effect the cement.4. Stir or shake cement before using. 5. Use 20 mm (¾") dauber on small diameter pipes,40 mm (1½") dauber up through 80 mm (3") pipe, and a natural bristle brush, swab, or roller ½ the pipe diameter on pipes 4" and up. 6. Do not mix cleaner or primer with cement. 7. Do not use thickened or lumpy cement. It should be like the consistency of syrup or honey. 8. Do not handle joints immediately after assembly. 9. Do not allow daubers to dry out. 10. Maximum temperature allowable for CPVC pipe is 180°F. 11. All coloured cements, primers, and cleaners will have a permanent stain. There is no known cleaning agent. 12. Use according to the step outline in ASTM D-2846, joining of pipe and fittings. Number of joints per liter of cement by pipe size IMPORTANT NOTES Dia of Pipe Appx. Nos (mm) (In.) of joints* 15 20 25 32 40 50 65 75 100 150 200 250 300 ½ ¾ 1 1¼ 1½ 2 2½ 3 4 6 8 10 12 1200 750 500 450 325 225 50 40 30 10 5 2-4 1-2 WATER HEATER CONNECTIONS L *Approximate numbers of joints which can be made per ltr. of solvent cement * For primer, number of joints are approximate double than solvent cement K Some plumbing codes contain detailed requirements for connections to gas or electric storage type water heaters. Determine whether your code has such requirements and satisfy SAFE HANDLING OF SOLVENT CEMENT When using solvent cements, primers and cleaners there are some basic safety measures. them. If no detailed requirements exist, use the following information. On electric water heaters CPVC can be piped directly to the heater with special metal- to- CPVC transition fittings (photo L). On gas water heaters there should be at least 6 inches All users should keep in mind. • Avoid prolonged breathing of solvent vapors. When pipe and K). Twelve inch long metal nipples or appliance connector should • Keep cements, primers and cleaners away from all sources of ignition, heat, sparks and open flame. cannot be damaged by the build-up of excessive radiant heat from • Keep containers of cements, primers and cleaners tightly closed except when the product is being used. fittings are being joined in enclosed areas, the use of ventilating devices are advised • • Dispose of all rags used with solvents in a proper outdoor waste receptacle. Avoid eye and skin contact. In case of eye contact, flush with plenty of water for 15 minutes and call a physician. of clearance between the exhaust flue and any CPVC piping (photo be connected directly to the heater so that the CPVC tubing the flue. An approved temperature/pressure (T/P) relief valve should be installed so that the probe or sensing element is in the water at the top of the heater. CPVC is approved by all the model codes for use as relief valve drain line piping. Use a metal-toCPVC transition fitting to connect to the relief valve and continue the pipe full size to the outlet. For horizontal runs, slope the pipe towards the outlet and support it at three-feet centers or closer. The pipe must discharge to the atmosphere at an approved THREAD SEALANTS location. Threaded CPVC fittings with tapered pipe threads (e.g. male thread adapters) must be used with a suitable thread sealant to Do not use CPVC pipe and fittings with commercial-type, non-storage water heaters. insure leak-proof joints. Over the years, PTFE (Teflon® or equivalent) tape has been the preferred thread sealant, it is still the most widely accepted and approved sealant. Some paste sealant can affect CPVC fittings; therefore only sealants recommended for use with CPVC by the thread sealant manufacturer should be used. 36 GENERAL GUIDELINE FOR ALL INSTALLATIONS DO's 1. 2. 3. 4. 4A. 4B. 4C. 5. 6. 7. 8. 8A. 9. 10. 11. 37 Install product according to ASTRAL's Installation instructions and manual and follow recommended safe work practices. Keep Pipe and Fittings in original packaging until needed and store pipes in covered areas. Use tools designed for use with plastic pipe and fittings. Cut-off minimum 25 mm beyond the edge of the crack in case any crack is discovered on the pipe. Pipe may be cut quickly and efficiently by several methods. Wheel-type plastic tubing cutters are preferred. Ratchet type cutters or fine tooth saws are another option. However, when using the ratchet cutter, be certain to score the exterior wall by rotating the cutter blade in a circular motion around the pipe. Do this before applying significant downward pressure to finalise the cut. This step leads to a square cut. In addition, make sure ratchet cutter blades are sharp. Cutting tubing as squarely as possible provides optimal bonding area within a joint. Burrs and filings can prevent proper contact between the tube and fittings during assembly, and should be removed from the outside and inside of the tube. A chamfering tool is preferred, but a pocket knife or file is also suitable for this purpose. Use CPVC Cement only. Use only CPVC Cement or an all purpose cement conforming to ASTM F-493 or joint failure may result. Always conduct hydraulic pressure testing after installation to detect any leaks and faults. Wait for appropriate cure time before pressure testing. Fill lines slowly and bleed air from the system prior to pressure testing. Rotate the pipe 90° to 180° to spread the CPVC Solvent Cement evenly in the joint while pushing the Pipe into Fitting. Use Teflon tapes with threaded fittings. Ensure that there are no sharp edges in contact with the pipe while embedding the pipes on the walls or in the floors. When making a transition connection to metal threads, use a special transition fitting or CPVC male threaded adapter whenever possible. Do not over-torque plastic threaded connections. Head tight plus one-half turn should be adequate. Provide Vertical & Horizontal Supports as recommended using the Plastic Straps only. Apply a water- based paint only on exposed pipes & fittings. Visually inspect all joints for proper cementing at the end of shift or day. A Visual inspection of the complete system is also recommended during pressure testing. 12. When connecting to a gas water heater, CPVC tubing should not be locat ed within 50cm of the flue. For water heaters lacking reliable temperature control, this distance may be increased up to 1m. A metal nipple or flexible appliance connector should be utilized. This measure eliminates the potential for damage to plastic piping that might result from excessive radiant heat from the flue. 13. Use of a brass/CPVC transition adapter when connecting CPVC to a water heater will help facilitate water heater replacement in the future. 14. Pressure test CPVC systems in accordance with local code requirements. DON'T's 1. Do not use Metal Hooks or Nails to support / hold or put pressure on the pipes. Do not use straps & hangers with rough or sharp edges. Do not tighten the straps over the pipes. 2. Never expose the pipe to Open Flame while trying to bend it. 3. Do not drop pipes on edges from heights. Do not drop heavy objects on pipes or walk on pipes. 4. Do not dilute Solvent Cement with Thinners /MTO or any other liquid etc. 5. Do not use air or gases for pressure testings. 6. Do not use any other petroleum or solvent- based sealant, adhesive, lubricant or fire stop material on CPVC pipes and fittings. 7. Do not use CPVC Pipes & Fittings for pneumatic applications. NOTES 38 OTHER PIPING SYSTEMS CPVC PIPING SYSTEM FOR INDUSTRIES • CPVC PIPING SYSTEM FOR FIRE SPRINKLERS • ULTRADRAIN CONVENTIONAL SYSTEM ASTM uPVC PIPING SYSTEM • DRAINAGE SYSTEMS • LIGHT WEIGHT FOAMCORE uPVC PIPES LEAD FREE & HEAVY METAL FREE COLUMN PIPES FOR SUBMERSIBLE PUMPS • MULTI-LAYER COMPOSITE PIPE LEAK PROOF uPVC DRAIN WASTE & VENT SYSTEM • uPVC PIPES FOR DRAINAGE & SEWERAGE APPLICATIONS THE LEADING SOUNDPROOF SOIL & WASTE SYSTEM • BATHROOM WITHOUT COMPROMISE Authorised Distributor : ASTRAL POLY TECHNIK LIMITED Registered & Corporate Office : 207/1, Astral House, B/h. Rajpath Club, Off. S.G. Highway, Ahmedabad-380 059, India. Phone : 91-79-6621 2000, Fax : 91-79-6621 2121, E-mail : info@astralcpvc.com Website : www.astralcpvc.com Mumbai : Unit No.138, Udyog Bhavan, Sonawala Road, Goregaon (E), Mumbai-400063. Phone : 022 - 2686 2227 Telefax : 022 - 2686 2397 E-mail : mumbai@astralcpvc.com New Delhi : 414, Ansal Chamber - II, 6, Bikaji Cama Place, New Delhi - 110 066. Phone : 011 - 2616 9461 Telefax : 011 - 2616 8156 E-mail : delhi@astralcpvc.com Bengaluru : No. 102, 1st floor, Bull Temple Road, Next To Ram Krishna Ashram, Bengaluru - 560019. Telefax : 080-26617236 E-mail : bgloffice@astralcpvc.com Hyderabad : Plot No. 67, 1st Floor, Paigah Colony, B/h. Anand Theatre, S.P. Road, Secunderabad-500 003. Telefax : 040 - 2790 0023 E-mail : hyderabad@astralcpvc.com Chennai : Flat No. AK6, 2nd Floor, “Natraj Palace”, No. 54 (22), Saravanan Street, T. Nagar, Chennai-600 017. Phone : 044 - 4350 6384 E-mail : chennai@astralcpvc.com All information contained in this manual is given in good faith and believed to be accurate and reliable. But because of many factors which are outside our knowledge and control and affect use of product, no warranty is given or is to be implied with respect to such information, nor we offer any warranty of immunity against patent infringement. No responsibility can be accepted for any error, omissions or incorrect assumptions. Any specification can change without prior notice. Spectrum : 09824097300 • • • • •
© Copyright 2024