DIVISION OF MIRO - Rooftop Sleeper Support

SLEEPER SUPPORT
DIVISION OF MIRO
RSS4
Providing contractors with a superior and economic product for rooftop conduit support. Rooftop Sleeper Support's
new RSS4 product will withstand extreme temperature swings, rain, ultraviolet light and wind while providing a safe
and reliable support for conduit while protecting the membrane on commercial rooftops. Made in the U.S.A. of 100%
recycled PVC, the RSS4 conduit support comes in a white color to match the trend in commercial roofing to energy
efficient white reflective roofs that reduce building energy consumption and decrease the effects of urban heat
islands and air pollution.
• The RSS4 is made out of 100% recycled PVC and will support a variety
of small conduit and condensate piping.
• RSS4 comes in a reflective white color to match the trend in commercial roofing to energy
efficient white reflective roofs that reduce building energy consumption.
• Superior alternative to wood blocks. The RSS4 has smooth, rounded edges that will
not crack, warp, blister and damage the rooftop membrane.
• Lightweight design makes for easy transport to the job site.
• Quick, easy installation.
• Backed by a 2 year limited warranty.
SLEEPER SUPPORT
DIVISION OF MIRO
RSS4
The RSS4 product
is designed for easy
rooftop conduit and
condensate pipe support
and helps protect against
roof penetrations and
damage to other rooftop
material.
Rooftop Sleeper Support Inc.
2700 South 900 West, Ste. 101
Salt Lake City, UT 84119
Geon Vinyl Dry Blend E1344
3 ½” High x 4’ Long, designed to be cut down to a length of 6” or longer
NOTE: Individual support pieces cannot be less than 6”
NOTE: Do not cut RSS4 product directly on roof membrane surface
3 ½” off roof membrane
Not to exceed 50 lbs per 6” or a maximum of 2.5 PSI
Should not exceed 10’ on center, closer depending on weight of pipe
Each support should be spaced evenly
2 Year
Installation Procedures:
1. Cut support to desired length.
2. Clear area around rooftop support.
3. Place support under pipe at 10’ on center or closer depending
on weight of pipe.
4. Pipe should be clamped loosely by a pipe clamp, pipe guide,
or other suitable fastener.
Manufacturer
Material Specifications
and Composition
Size
Max Pipe Clearance
Max Load Weight
Spacing
Warranty
Rooftop Sleeper Support, Inc.
2700 South 900 West, Ste. 101
Salt Lake City, Utah 84119
Phone: 801-975-8885
Fax: 801-975-6351
sales@rooftopsleepersupport.com