ICM In-line Contamination Monitor

LPA View Software
When connected to LPA View, the ICM can transfer results
in realtime, or alternatively historical results can be
downloaded from the ICM’s inbuilt memory.
● Runs on Windows 2000, XP, Vista and Windows 7.
● F ull adjustment & control of product settings,
test times and alarms
● Easy test report generation
● Trend analysis
● Graphical display options
● Universal format across our contamination monitoring product range
How to Order
Example: ICM - W - M - K - R - G1
ICM
W
M
K
R
G1
ICM Can be used as a standalone product or can be
controlled by an external PC, PLC or the ICM-RDU
Remote Display Unit. 3m control cable supplied as standard.
Warranty and
Recalibration
W Water and Temperature Sensing
* For high frequency pressure pulse applications contact MP Filtri.
Enter W if required, or 0 if not.
Warranty The ICM is
guaranteed for 12 months
from date of receipt.
M Mineral Oil Fluid Compatibility.
N Offshore and selected water based fluids*.
S Phosphate Ester and aggressive fluids*.
* Consult MP Filtri. Note: N and S models are supplied with anodised outer case
and are not available with water sensing option.
K Keypad – Adds 6 key keypad and 128 x 64 pixel back-lit graphical display.
Enter K if required, or 0 if not.
R Relays. Enter R if required, or 0 if not.
Re-calibration The ICM
is recommended to be
recalibrated every 12
months.
Return to MP Filtri for
recalibration.
As a policy of continual
improvement, MP Filtri
reserve the right to alter the
specification without prior
notice.
Port Options
G1 ICM complete with minimess connections M16 x 2.
G3 1/4” BSP Ports.
G4 7/16" UNF.
Caution
Hydraulic systems contain dangerous fluids at high pressures and temperatures. Installation, servicing and adjustment
are only to be performed by qualified personnel. Do not tamper with this device. Do not use this
product outside the parameters specified in this document & other related literature.
ITALY (Head Quar ters)
MP FILTRI S.p. A .
CANADA
MP FILTRI CANADA Inc.
FR ANCE
MP FILTRI FR ANCE
Russian Federation
MP Filtri Russia Inc
Tel. +39.02/95703.1
Fa x +39.02/9 5741497
9574018 8
email: sales@mpf iltri.com
ht tp://w w w.mpf iltri.com
Tel: +1.905 -303 -1369
Fa x: +1.905 -303 -7256
email:mail@mpf iltricanada.com
ht tp://w w w.mpf iltricanada.com
Tel: +33.40 - 86 - 47- 0 0
Fa x: +33.40 - 86 - 47- 09
email: contact@mpfiltrifrance.com
ht tp://w w w.mpf iltri.com
Phone mobile: +7.095 - 502- 5411
Fa x: +7.095 -205 - 9410
email: m pfiltrirussia@yahoo.com
ht tp://w w w.mpf iltri.ru
UNITED KINGDOM
MP FILTRI UK Ltd.
GERMANY
China
MP Filtri (Shanghai) Co Ltd MP FILTRI D GmbH
Tel: +4 4.01451- 822522
Fa x: +4 4.01451- 822282
email: sales@mpf iltri.co.uk
ht tp://w w w.mpf iltri.com
ht tp://www.hydraulicparticlecounter.com
Tel: +86.21- 58919916
Fa x: +86.21- 58919667
sales@mpf iltrishanghai.com
ht tp://w w w.mpf iltrichina.com
Tel: +1.215 - 529 -130 0
Fa x: +1.215 - 529 -1902
email: sales@mpf iltriusa.com
ht tp://w w w.mpf iltriusa.com
www.hydraulicparticlecounter.com
Doc No: 20 0.0 02 Rev: 1 01/10 D CR:
www.mpfiltri.com
Tel: +49.06806 - 85022.0
Fa x: +49.06806 - 85022.18
email: ser vice@mpf iltri.de
ht tp:// w w w.mpf iltri.com
USA
MP FILTRI USA Inc.
ICM
In-line Contamination Monitor
The ICM automatically measures and
displays particulate contamination,
moisture and temperature levels in
various hydraulic fluids. It is designed
specifically to be mounted directly to
systems, where ongoing measurement
or analysis is required, and where
space and costs are limited.
● 8 channel contamination
measurement & display
● Measures and displays the
following international standard
formats; ISO 4406:1999,
NAS 1638, AS 4059E and
ISO 11218
● Moisture and temperature sensing
● Data logging and 4000 test result
memory
● Manual, automatic and remote
control flexibility
● Multicolour LED and remote alarm
signals
● Robust die cast aluminium
construction
Doc No: 20 0.0 02 Rev: 1 01/10 D CR:
● LPA View software (included)
www.mpfiltri.com
www.hydraulicparticlecounter.com
Installation
The ICM must be in a vertical orientation, with the oil flowing upwards through it.
84 ±1
57 ±1
2x Ø7
MOUNTING
232 ±2
259 ±2
169 ±2
G1 Option
115 ±2
G3 & G4 Options
126.00
141 ±2
27 ±0.5
65 ±1
ICM with Flow Control Valve and Minimess fitting
M N S Fluid Compatability
K Keypad Option
The ICM can operate across a number of fluid types.
The fluid compatability option meets the needs of
most major hydraulic markets.
M = Synthetic, petroleum & mineral based fluids.
N*= Offshore and selected water based fluids.
S*= P hosphate Ester & Aggressive fluid
applications**.
K version
Non K version
R Relays
The ICM “R” option displays & operates over
8 channels comprehensively covering all of
the applied standard formats. It allows fully
customisable alarm settings and indicates these
via a multicolour LED and/or remote devices.
Alarm Types
● Contamination codes and/or individual particle sizes
● Water content ● Temperature
* Note; When purchasing an “R” model, the alarms are factory set to off,
and must be activated via LPA View
LED indicator colours
● - Test OK
● - Lower cleanliness level exceeded. Upper limit ok
● - Upper cleanliness level exceeded
● - Upper water content limite exceeded
●●- R ed/Blue alternating indicates cleanliness and
water limit have been exceeded
● - Upper temperature limit exceeded
*Please note, the N & S versions are supplied with an anodised aluminium
outer casing and are not available with water sensing option. The M version
can be supplied with either a polyester vinyl paint or anodised finish. See
specification table for more details. ** Consult MP Filtri.
W Water and Temperature
Sensing
The ICM “W” option
indicates water content as
a percentage of saturation
and oil temperature in
degrees centigrade. 100% RH
corresponds to the point at
which free water can exist in the
fluid. i.e. the fluid is no longer
able to hold the water in a dissolved solution.
The sensor provides early indication of costly
failure due to free water, including but not
exclusive to;
● Corrosion
● Metal surface fatigue e.g. bearing failure
● R
educed lubrication & load carrying
characteristics
* Note; Alarm limits shall be defined and enabled by the user
www.hydraulicparticlecounter.com
Specification
Technology
L ED Based Light Extinction
Automatic Optical Particle
Counter
Particle Sizing
4,6,14,21,25,38,50,70 µm(c)
>
to ISO 4406 1999 Standard
Analysis Range\
Formats
ISO 4406: 1999 Code 0 to 25
NAS 1638 Class 00 to 12
AS4059 Rev.E. Table 1&2 Sizes
A-F: 000 to 12 ISO 11218 00-12
Test Time
djustable 10 - 3600 seconds.
A
Factory set to 120 seconds
Outer Casing
Finishes
Anodised Aluminium (dark grey)
Polyester Vinyl Paint (light grey)
Moisture Sensing
% RH (Relative Humidity) ±3%
Wetted parts
Temperature
Measurement
±3°C
Flow rate
measurement
Indication only
M-C
46400 Cu alloy, 316
stainless steel, viton, FR4,
sapphire.
N-3
16 stainless steel, viton,
sapphire.
S-3
16 stainless steel, perfluoro
elastomer, sapphire.
Data Storage
4000 tests.
(Lower Limits are Test Time dependent)
Comms Port
RS485, RS232, MODBUS
Accuracy
½ code for 4, 6 14um(c).
±
± 1 code for larger sizes.
-25°C to 80°C non K version
-25°C to 55°C K version
Calibration
ach unit individually calibrated
E
with ISO Medium Test Dust (MTD)
based on ISO 11171 (1999), on
equipment certified by IFTS.
Ambient
Temperature min/
max
IP Rating
IP 65/67 versatile
Weight
1.15kg
Electrical Supply
Voltage 9-36V DC
Supply Current
12V 24V 36V
Basic Unit
70mA 40mA 30mA
80mA 60mA
Operating Flow Rate
20 - 400 ml/minute
Viscosity Range
≤ 1000 cSt
Fluid Temperature
–25 to +80 °C
With -K (Keypad)
150mA Pressure Max
400 barg.
Power
Consumption
<2.2W
* For high frequency pressure pulse
Differential Pressure vs Fluid
Viscosity, for various flow rates.
applications contact MP Filtri Ltd
Optional Related Products
y
.
um
ion
e
ICM “USBi” Connector
ICM-RDU
The USBi transmits power and allows the ICM to
communicate with a PC or laptop. Where customers wish
to wire to external devices the USBi has an extra terminal
block inside for this purpose. An external DC adaptor can
be used to power the complete system, or if a computer
is always connected during use, the ICM can be powered
directly from the USB cable.
The ICM RDU (Remote Display Unit) is
advantageous when the ICM is out of reach
or in a location unsuitable for viewing. The
ICM can also be controlled via the RDU.
How to order
Order 1 x ICM-USBi
*Note; Installation dimensions are the same as the ICM.
How to order
Order 1 x ICM-RDU
ICM-FC1
Offline Filtration Units
A pressure compensated flow control valve
specifically designed to fit the ICM. This may be
needed if the application produces an oil flow greater
than 400ml/min through the ICM.
Offline filtration units with integrated ICM
are available – please consult
MP Filtri for further information
ICM-FC1 - is supplied with adaptors which enable the
valve to be fitted to the ICM. The valve outlet port
has a minimess fitting installed as a standard option.
Max Pressure - 400barg
Usable Flow Range -4barg to 400barg ΔP
How to order Order 1 x ICM-FC1
For alternative connection types contact MP Filtri
www.hydraulicparticlecounter.com