GENERAL LEGEND NOTES: 1. 2. CONDUIT, CONCEALED IN FINISHED AREAS, EXPOSED IN UNFINISHED AREAS. 1. Work Included: Construct complete, functional, electrical systems as shown on these plans and described below. Coordinate all work with, owner, engineer and other trades. Obtain and pay for any necessary permits and fees for the electrical work. 2. Existing site conditions: Visit the site prior to bid and inform yourself as to all existing conditions and limitations that may affect the work. No allowances for extra expense will be made for neglecting to discover conditions affecting this work. CONDUIT BURIED OR EMBEDDED 4x4 FIR BLOCKING CONDUIT BEND UP CONDUIT BEND DOWN 1/4" Ø x 3" LAG BOLT - TYP. OF 4, SEE NOTE 1 CONDUIT STUBBED AND CAPPED # CONDUIT AND CONDUCTORS (OR CABLE WHERE ALLOWED), SLASHES INDICATE NUMBER OF CONDUCTORS. LONG SLASH IS NEUTRAL. # IS SIZE OF CONDUCTOR (#12 IF NO NUMBER IS SHOWN) UNMARKED RUNS INDICATE 2#12. INCLUDE ADDITIONAL EQUIPMENT GROUND AS INDICATED IN GENERAL NOTES ON THIS SHEET SIZE CONDUIT PER N.E.C. WALL STUDS SIMPSON A34 FRAMING ANGLE FILLED WITH (8) 8d x 1-1/2" NAILS - TYP. AT EA. END OF 4x4 - SEE NOTE 2. 6' - 0" 10 EXAMPLE - 4#10 CONDUCTORS IN 1/2"MIN. CONDUIT. (1 OF THE 4 IS NEUTRAL) - IF REQUIRED BY GENERAL NOTES INCLUDE ADDITIONAL #10 EQUIPMENT GND. PANEL HOUSING FEEDER # - SEE ONE LINE DIAGRAM FOR CONDUIT AND CONDUCTOR SIZES. FINISHED FLOOR 1 SCALE: 1/2"=1'-0 SURFACE PANEL MOUNTING 3. ONE LINE LEGEND CIRCUIT BREAKER TRIP AMPS / # POLES SHOWN 30/3 100/3 90 FUSIBLE SWITCH - SWITCH AND FUSE AMPS / # POLES SHOWN 2 MAGNETIC MOTOR STARTER WITH O/L RELAY - NEMA SIZE SHOWN JUNCTION BOX -- SIZE PER N.E.C. 4. TRANSFORMER - RATINGS SHOWN DELTA-WYE CONNECTION SHOWN MECHANICAL EQUIP. DESIGNATION - UNIT SUPPLIED UNDER MECH. SPEC.'S POWER LEGEND 1/4" Ø x 1-1/2" LAG BOLT - TYP. OF 4 SEE NOTE FEEDER # - THIS # IS SHOWN ON POWER PLANS TO IDENTIFY THIS FEEDER DUPLEX CONVENIENCE OUTLET MOUNTED +18" ABOVE FINISH FLOOR TO BOX CENTER UNLESS NOTED OTHERWISE. SUBSCRIPTS: GFI - GROUND FAULT CIRCUIT INTERRUPTER WP - WEATHERPROOF IG - ISOLATED GROUND CKT.# WALL STUDS x PANEL HOUSING FLOOR MOUNTED DUPLEX RECEPTACLE SUBSCRIPTS: F = FLUSH P = PEDESTAL DOUBLE DUPLEX RECEPTACLE CONNECTION POINT TO EQUIPMENT FURNISHED AND INSTALLED UNDER THE MECHANICAL OR OTHER SECTIONS OF THE SPECIFICATIONS. FIN. FLOOR SCALE: 1/2"=1'-0 EQ 2 RECESSED PANEL MOUNTING 60/2 F NOTE : 60/40/2 1. MAINTAIN 12" HORIZ & VERTICAL CLEARANCE TO GAS PIPE(S) 2. MAINTAIN 36" HORIZ & 12" VERTICAL CLEARANCE TO WATER OR SEWER 3. INSTALL ELECTRICAL SERVICE TRENCHES & JOINT SERVICE TRENCHES IN ACCORDANCE WITH ALL UTILITY CO. STD'S. INCLUDING MIN. DEPTHS, CLEARANCES, BACKFILL, GROUNDING, AND PULL CORDS OR WIRES. SPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION CODE SHOWN. "EQ" MEANS DETERMINE TERMINATION FROM EQUIPMENT SUPPLIER. FACP FLEX ,FMC FIRE ALARM CONTROL PANEL FLEXIBLE METALLIC CONDUIT # SHADING THROUGH FIXTURE INDICATES BATTERY FOR EMERGENCY LIGHTING G, GND GFI GROUND GROUND FAULT CIRCUIT INTERRUPTER # SLASH MARK THROUGH FIXTURE INDICATES RECESSED FIXTURE IMC INTERMEDIATE METALLIC CONDUIT MIN. MSB MINIMUM MAIN SWITCHBOARD (N) N, NEUT. NC NO NIC NM NMT NEW NEUTRAL NORMALLY CLOSED NORMALLY OPEN NOT IN CONTRACT NON-METALLIC SHEATHED CABLE (ROMEX) NON-METALLIC TUBING WALL SWITCH -- MOUNT +48" AFF TO BOX CENTER SUBSCRIPTS: M = MOMENTARY CONTACT MD= MOTION DETECTOR 2 = DOUBLE POLE D = DIMMER 3 = THREE WAY K = KEY OPERATED 4 = FOUR WAY T = TIME SWITCH WP = WEATHERPROOF a, b, ETC. = SWITCH OPERATES ALL FIXTURES WITH SAME SUBSCRIPT OL OVERLOAD RELAY PNL PANEL UNO UNLESS NOTED OTHERWISE DUAL HEAD EMERGENCY LIGHT - SEE LFS WP WEATHER PROOF # OPEN STRIP FLUORESCENT - SEE SCHEDULE ILLUMINATED EXIT SIGN, QUADRANT(S) FILLED INDICATE DIRECTIONS OF FACE(S). ARROW INDICATES DIRECTIONAL ARROW ON SIGN. SEE LIGHTING FIXTURE SCHEDULE TYPE "EXIT" PRE-CAST CONCRETE VALVE BOX LL Sx FINISH GRADE 5/8" Ø x 10'-0" COPPER CLAD GROUND ROD BURNDY TYPE "GAR" GROUND CLAMP OR EQUAL (ONE PIECE WITH SINGLE BOLT UL LISTED FOR DIRECT BURIAL) GROUND ELECTRODE CONDUCTOR SEE 1-LINE SCALE: NONE 4 GROUND ROD INSTALLATION ABBREVIATIONS FIXTURE INTER TIE FOR MASTER/SLAVE WIRING OF 3-LAMP FIXTURES # CONDUIT(S) SCHD 40 PVC # LOW LEVEL EXIT SIGN - SEE TYPE 'EXIT-LL" Service continuity: Maintain continuity of all electrical systems to all functioning areas and processes in buildings being remodeled. Coordinate all unavoidable outages with the owner. Keep such outages to a minimum. Supply any necessary temporary wiring. Include any cost for overtime work in your bid. (R) RA RMC REMOVE RETURN AIR (HVAC EQUIP.) RIGID METALLIC CONDUIT SA SWBD SUPPLY AIR (HVAC EQUIP.) SWITCHBOARD XFMR TRANSFORMER +## HEIGHT IN INCHES ABOVE FIN. FLOOR, INDOOR HEIGHT IN INCHES ABOVE FIN. GRADE, OUTDOOR ALL HEIGHTS ARE TO BOX CENTER CHECK ALL SYMBOLS TO MAKE SURE YOU UNDERSTAND WHAT THEY INDICATE ON THESE PLANS. SHEET E-1 IS A STANDARD SHEET AND MAY INCLUDE SYMBOLS AND DETAILS NOT INCLUDED IN THIS PROJECT. 1. ALL CONDUCTORS SHALL BE COPPER WITH THWN/THHN INSULATION UNLESS NOTED OTHERWISE 2. PANEL AND EQUIPMENT FEEDERS: INDIVIDUAL CONDUCTORS IN CONDUIT UNLESS NOTED OTHERWISE. 3. BRANCH CIRCUIT WIRING: INDIVIDUAL CONDUCTORS IN CONDUIT UNLESS NOTED OTHERWISE. 4. USE THESE CONDUIT TYPES: EXTERIOR OR INTERIOR WET LOCATIONS: EMT WITH WATERTIGHT COMPRESSION CONNECTORS OR SCHEDULE 80 PVC UNDERGROUND: SCHEDULE 40 PVC LICENSE STAMPS EQUIPMENT CONNECTIONS AND FIXTURE WHIPS - INTERIOR DRY LOCATIONS: FLEX OR TYPE MC CABLE Wiring methods: See General Notes on this page. CABINETS AND BUILT-IN FURNITURE: TYPE MC (METAL CLAD) CABLE 11. Conduit: Interior: EMT Exterior: RMC or Schedule 80 PVC. Underground or embedded: Sched. 40 PVC with 4" sand bedding and rock free backfill . Minimum burial depth per NEC /CEC Table 300-5 Wiring devices: Furnish general duty commercial grade switches and receptacles as manufactured by Hubbell , Eagle, Pass and Seymour or Bryant. Furnish plates of high impact thermoplastic or nylon. Supply gasketed weatherproof plates outdoors with vertical cover mounted with hinge up. At interior unfinished areas furnish cast metal plates that do not extend past edges of a surface mounted box. 14. Lighting fixtures: supply lighting fixtures as shown on the lighting fixture schedule. 15. Grounding: Provide green insulated grounding conductors on all receptacle branch circuits and panel feeder circuits. Ground all exposed non-current carrying metallic parts of electrical equipment and raceway systems. Ground metal sheathing and any exposed metal vertical structural elements of buildings. Bond all metallic piping systems to ground. 16. HAZARDOUS AREAS: RMC E. WIRING METHODS FOR LOW VOLTAGE, CLASS 2 POWER LIMITED CONTROL: USE SAME METHODS AS SHOWN FOR NON-POWER LIMITED SHOWN ABOVE EXCEPT LISTED CABLES TYPE CL2P MAY BE SUBSTITUTED IN CONCEALED, INTERIOR, DRY LOCATIONS NOT SUBJECT TO PHYSICAL DAMAGE. PROJECT NAME YIHA STORAGE GARAGE KLAMATH, CA 95548 SHEET TITLE ELECTRICAL LEGENDS, DETAILS Ground rods: Provide copper clad steel ground rods not less than 3/4 inch diameter, 10 feet long driven full length into the earth. Provide exothermic welded connection or ground clamps UL listed for direct burial. 17. Notching: don't notch any building structural member without the permission of the engineer or architect. 18. Support: Support lighting fixtures securely from building structure. Support fixtures independently of the suspended ceiling. Secure all electrical equipment including conduits and boxes securely from building structure or floor slab. Meet all seismic support and bracing requirements for CBC seismic zone 4. 19. CONSULTANTS INTERIOR OR EXTERIOR EXPOSED TO VEHICULAR TRAFFIC: RMC 19. 13. All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by, and the property of David PierceArchitect and were created, evolved and developed for use on, and in conjunction with, the specified project. None of such ideas, designs, arrangements or plans shall be used by, or disclosed to any peson, firm or corporation for any purpose whatsoever without the written permission of David Pierce Architect. INTERIOR CONCEALED AND EXPOSED: EMT EQUIPMENT CONNECTIONS AND FIXTURE WHIPS - EXTERIOR OR INTERIOR WET LOCATIONS: LIQUID TIGHT FLEX OR PVC JACKETED TYPE MC CABLE Circuit breaker panelboards: Supply panelboards with bolt on breakers. Use only full, 1" frame breakers. Tandem or double breakers are not acceptable. Panels and breakers shall be rated to interrupt the maximum fault current available at the panel location. For every house is builded by some man; but he that built all things is God. Hebrews 3:4 WIRING METHODS FOR POWER, LIGHTING AND NON-POWER LIMITED CONTROL WIRING--USE THE FOLLOWING: Conductors: Unless noted otherwise, supply copper conductors with THWN / THHN insulation. 12. 95536 (707) 786-4266 FAX (707) 786-4966 9. CONC. PULL BOX 24"x36"x30" DEEP (MIN.) EXISTING ELECTRICAL METALLIC TUBING ELECTRICAL NONMETALLIC TUBING # 8. CONC. PULL BOX 17"x30"x12" DEEP (MIN.) (E) EMT ENT DIRECTIONAL FIXTURE, AIMING DIRECTION SHOWN # Substitutions and Submittals : Follow procedures described in the General Conditions. CONC. OR FIBERGLASS PULL BOX 10"x17"x12" DEEP (MIN.) LUMINAIRE, SEE LIGHTING FIXTURE SCHEDULE POLE MOUNTED FIXTURE 24" MIN. 18" MIN. 7. CONC. OR FIBERGLASS PULL BOX 13"x24"x12" DEEP (MIN.) CONDUIT CIRCUIT BREAKER CURRENT LIMITING FUSE CONDUIT ONLY, (WITH PULL ROPE) COPPER CEILING MOUNTED FIXTURE (600V AND LOWER) CABLE TV SERVICE CONDUIT C CB, BKR CLF CO CU, Cu LIGHTING LEGEND WALL MOUNTED FIXTURE TYPICAL CONDUIT TRENCH TELEPHONE SERVICE CONDUIT(S) TV AMPERE C.B. FRAME AMPERE RATING ABOVE FINISH FLOOR ABOVE FINISH GRADE AMPS INTERRUPTING CAPACITY ALUMINUM C.B. TRIP AMPERE RATING ARMORED CABLE (BX) CROSSING PIPE 3 SECONDARY ELECT. SERVICE CONDUIT(S) T A, AMP. AF AFF AFG AIC Al AT AC DUAL CHANNEL SURFACE RACEWAY OUTLETS WHERE SHOWN PLASTIC WARNING TAPE SCALE: NONE S 12" MULTI-OUTLET STRIP, LENGTH DRAWN TO SCALE, RECEPTACLE SPACING IN INCHES SHOWN WIDTH AS REQ'D 12" MIN. PRIMARY (HIGH VOLTAGE) ELECT. SERVICE CONDUIT(S) DISCONNECT SWITCH, NON-FUSED, AMP RATING/NUMBER OF POLES INDICATED FUSIBLE DISCONNECT SWITCH SWITCH AMPS/FUSE AMPS/NUMBER OF POLES INDICATED FINISH GRADE 4" SAND BEDDING AND COVER P D. Intent of drawings: Drawings show approximate locations only. Contractor is responsible for correct positioning of equipment, adequate clearances and routing of conduits. Report any conflicting conditions to the architect or engineer prior to proceeding with the work. SITE PLAN LEGEND WIRE RECEPT. TO CKT # SHOWN USING #12 CONDUCTORS. 6' - 0" CLOSE COORDINATION BETWEEN THE ELECTRICAL AND MECHANICAL TRADES IS A PART OF THE WORK THAT IS REQUIRED BY THIS CONTRACT. NO ALLOWANCE WILL BE MADE FOR OMISSIONS BASED ON INCORRECTLY ASSUMING ANOTHER TRADE WILL BE PERFORMING YOUR WORK. REFER TO THE SPECIFICATIONS AND CONFIRM YOUR SCOPE OF WORK WITH THE GENERAL CONTRACTOR. Comply with the National Electrical Installation Standards published by the National Electrical Contractors Association. (NECA) including the following: NECA 1, Standard Practice of Good Workmanship in Electrical Contracting 6. CURRENT TRANSFORMER B. THE MECHANICAL / ELECTRICAL INTERFACE: C. STANDARD LEGENDS AND DETAILS: Products: Supply all new equipment. Only supply equipment listed by UL or other nationally recognized testing laboratory. Like items of equipment shall be the products of a single manufacturer. GROUND FOR METAL STUDS USE #12 SELF TAPPING SHEET METAL SCREWS, SIX SCREWS ON EACH SIDE. A. ANY DEVIATION FROM THE APPROVED ELECTRICAL PLANS WILL REQUIRE APPROVAL FROM THE ELECTRICAL DESIGNER OF RECORD, PER CALIFORNIA BUSINESS & PROFESSIONS CODE. Comply with applicable codes and standards including the following: The currently applicable California Electrical Code. The currently applicable California Building Code Requirements of state and local fire marshals. Americans with Disabilities Act 5. KEYNOTE NOTE: GENERAL NOTES ELECTRICAL SPECIFICATIONS HOME RUN, DESTINATION SHOWN ON C.M.U. WALLS USE (4) 3/8"x 3-1/2" EMBED HILTI HIT ANCHORS. ON METAL STUD WALLS USE #12 SHEET METAL SCREWS. DRAWING STATUS PLAN CHECK REVISIONS Sym. Description Date 1 2 3 4 Penetrations: Flash, counterflash, seal and make watertight any roof penetrations. Grout and seal penetrations through floor slabs and CMU walls. Provide paintable metal escutcheons in finished areas. Install UL listed fire sealant at conduit penetrations through fire rated partitions in accordance with an approved UL System. 5 6 7 8 20. Construction observation: Work is subject to observation by the engineer. Correct work to comply with the plans and these specifications to satisfaction of the engineer. 21. Warranty: As a minimum, guarantee all work for one full year from the date of the owner's first beneficial use. Checked By 22. Final test: Upon completion, perform a complete test and demonstration of all systems in the presence of the engineer and owner. Remove panel covers as requested by the engineer. Check for proper motor rotation and panelboard load balance. Job No. H.MAURO Drawn By Scale PRELIMINARY NOT FOR CONSTRUCTION ELECTRICAL ENGINEER 317 Third Street, Suite 11 Eureka, CA 95501 (707)445-2163 tel (707)445-2426 fax AS NOTED DPA11YIHA1 SHEET No. E-1 NOTE: INFORMATION PERTAINING TO EXISTING UNDERGROUND FACILITIES AS SHOWN HEREIN IS FOR INFORMATION PURPOSES ONLY. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL AGENCIES INVOLVED AND SHALL LOCATE ALL FACILITIES PRIOR TO EXCAVATION IN ANY AREA. KEY NOTES NEW STORAGE GARAGE SUPPLY GFCI TYPE CIRCUIT BREAKERS (E) ADMIN. OFFICE 95536 (707) 786-4266 FAX (707) 786-4966 NEW PANEL B For every house is builded by some man; but he that built all things is God. Hebrews 3:4 RUN A SPARE 1-1/4" EMPTY CONDUIT IN TRENCH WITH PANEL B FEEDER P2 Copyright C 2011 All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by, and the property of David PierceArchitect and were created, evolved and developed for use on, and in conjunction with, the specified project. None of such ideas, designs, arrangements or plans shall be used by, or disclosed to any peson, firm or corporation for any purpose whatsoever without the written permission of David Pierce Architect. CONSULTANTS (E) SHOP LICENSE STAMPS (E) SHOP PANEL (E) METER / MAIN BKR SERVICE PANEL PROJECT NAME SCALE: 1"=20' 1 ELECTRICAL POWER PLAN YIHA STORAGE GARAGE KLAMATH, CA 95548 (E) PG&E SERVICE DROP 120/240V, 1 PH, 3W SHEET TITLE ELECTRICAL SITE PLAN KWH (E) COMBINATION METER/ MAIN BKR SERVICE PANEL DRAWING STATUS 200A/2P MAIN BKR PLAN CHECK NEW PANEL (E) SHOP PANEL NEW 70/2 BKR REPLACES (2)SPARE 20/1 BKRS B DO NOT BOND FEEDER NEUTRAL TO GROUND REVISIONS GND Sym. Description Date 1 2 3 #8 Cu - IN CONDUIT WHERE EXPOSED 4 5 6 (E) FEEDER - NO CHANGE 7 1-1/4"C - 3#4, 1#8G BUILDING STEEL FRAME (N) GND ROD 8 H.MAURO Drawn By Checked By SCALE: NONE 2 SINGLE LINE DIAGRAM Scale AS NOTED DPA11YIHA1 Job No. SHEET No. E-2 LIGHTING FIXTURE SCHEDULE TYPE NO: DESCRIPTION: A 96" INDUSTRIAL FLUORESCENT WITH WHITE POWDER COAT REFLECTORS, AND WIRE GUARD MOUNTING: 24" CHAIN SUSPENDED (#LAMPS)TYPE: (2) FO32/750/ECO BALLAST/VOLTS: ELECTRONIC LOW TEMP. START / 120 INPUT WATTS: 60 MFR CAT.#: WILLIAMS 80-8-232-VBY-2-WG-8014-EBLO-120 KEY NOTES BOND ALSO TO BUILDING STEEL FRAME - SEE 1-LINE DIAGRAM TYPE NO: DESCRIPTION: B 48" GASKETED INDUSTRIAL FLUORESCENT - UL LISTED FOR WET LOCATIONS - FIBERGLASS HOUSING AND HIGH IMPACT ACRYLIC DIFFUSER MOUNTING: 12" CHAIN OR CABLE SUSPENDED (#LAMPS)TYPE: (1) FO32/750/ECO BALLAST/VOLTS: ELECTRONIC LOW TEMP. START / 120 INPUT WATTS: 30 MFR CAT.#: WILLIAMS 96-4-132-PC-WET/1-EBLO2-120 BRING BOTH EVENING USE AND SECURITY CIRCUITS TO ALL FIXTURES SO THEY CAN BE EASITLY CHANGED IN FUTURE IF DESIRED. 10 10 CONNECT EXIT SIGNS TO THE UNSWITCHED LEG OF LIGHTING CIRCUIT B2 B3 B5 MOUNT THESE SWITCHES NEXT TO DOOR. LABEL THE ON POSITION OF THE SWITCHES AS "AUTO" AND THE OFF POSITION AS "OFF". TYPE NO: DESCRIPTION: C WALL LIGHT - 13"W x 12"H - DIE CAST ALUMINUM HOUSING - DARK BRONZE FINISH POLYCARBONATE LENS MOUNTING: WALL CENTERED ABOVE GARAGE DOORS (#LAMPS)TYPE: (1) 70W METAL HALIDE BALLAST/VOLTS: HPF / 120 INPUT WATTS: 95 MFR CAT.#: DAYBRITE WLI070MDT 10 SHEET LEGEND SEE ALSO SHEET E-1 CEILING MOUNTED, LOW VOLTAGE OCCUPANCY SENSOR - EXTENDED RANGE, PASSIVE DUAL TECH. - SENSOR SWITCH CM-PDT-10 CLASS II LOW VOLTAGE WIRING TO MOTION SENSORS INSTALL IN CONDUIT GROUND ROD WP WP PANEL"B" +48 +48 +48 For every house is builded by some man; but he that built all things is God. Hebrews 3:4 Copyright C 2011 All ideas, designs, arrangements and plans indicated or represented by this drawing are owned by, and the property of David PierceArchitect and were created, evolved and developed for use on, and in conjunction with, the specified project. None of such ideas, designs, arrangements or plans shall be used by, or disclosed to any peson, firm or corporation for any purpose whatsoever without the written permission of David Pierce Architect. CONSULTANTS D FLOOD LIGHT APPROX. 10" SQ x 7"D- DARK BRONZE FINISH- DIE CAST ALUMINUM HOUSING MOUNTING: WALL MOUNT - ADJUSTABLE (#LAMPS)TYPE: (1) 70W METAL HALIDE BALLAST/VOLTS: HPF / 120 INPUT WATTS: 95 MFR CAT.#: WILLIAMS FL2-PSMH-70-120 RELAY - POWER PACK B1 FAX (707) 786-4966 TYPE NO: DESCRIPTION: 10 PP 95536 (707) 786-4266 TYPE NO: DESCRIPTION: E SMALL WALL LIGHT - POLYCARBONATE HOUSING AND LENS - DARK BRONZE FINISH MOUNTING: WALL MOUNT AT HEIGHT SHOWN (#LAMPS)TYPE: (1) 26W COMPACT FLUORESCENT BALLAST/VOLTS: LO TEMP START / 120 INPUT WATTS: 26 MFR CAT.#: DAYBRITE WL26CFU B7 SEE SITE PLAN ]TYPE NO: DESCRIPTION: SCALE: 1 1/8"=1'-0 XE COMBINATION ILLUMINATED EXIT SIGN / EMERGENCY LIGHTING WITH 90 MINUTE BATTERY BACK-UP. WHITE HOUSING, 6" RED LETTERS. SINGLE OR DOUBLE FACED AS SHOWN, WITH ARROWS AS SHOWN. LED ILLUMINATION WITH (2) 5.4 WATT HALOGEN LAMPS MOUNTING: WALL OR CEILING SURFACE AS SHOWN (CENTER ABOVE DOORS) (# LAMPS)TYPE: LED BALLAST/VOLTS: /120 INPUT WATTS: LESS THAN 5 MFR CAT.#: WILLIAMS EXIT/EM-SF-R-WHT WEIGHT: LESS THAN 20 LBS LICENSE STAMPS ELECTRICAL POWER PLAN NOTES: 1. VERIFY ALL CATALOG NUMBERS. SUPPLY ALL MOUNTING HARDWARE AND ACCESSORY ITEMS REQUIRED FOR A COMPLETE, FUNCTIONAL INSTALLATION MEETING ALL REQUIREMENTS OF THE DESCRIPTION AND THE SPECIFICATIONS. 2. BALLASTS -- GENERAL: SUPPLY U.L. LISTED BALLASTS COMPATIBLE WITH LAMPS SHOWN ON FIXTURE SCHEDULE. ALL BALLASTS INSTALLED INDOORS SHALL HAVE A CLASS A SOUND RATING UNLESS NOTED OTHERWISE. ALL H.I.D. AND COMPACT FLUORESCENT BALLASTS SHALL BE HIGH POWER FACTOR TYPE UNLESS NOTED OTHERWISE. FLUORESCENT BALLASTS SHALL HAVE A CLASS P THERMAL RATING. EXTERIOR LIGHTING CONTROLLER INTERMATIC ET8215C s E +84 +84 e E +84 E 7-DAY, 2-CIRCUIT ASTRONOMIC ELECTRONIC TIME SWITCH NEMA 1 ENCLOSURE e CKT #1: B A e A A A e B CKT #2: 14 A DUSK ON / TIME OFF / TIME ON / DAWN OFF / (EVERY DAY) LCD DISPLAY KEY PAD 3. CKT 1 L A A A e B C NO NC 120V CKT B4 e YIHA STORAGE GARAGE KLAMATH, CA 95548 SHEET TITLE ELECTRICAL PLAN BALLASTS -- ELECTRONIC: SUPPLY BALLASTS MEETING THE FOLLOWING REQUIREMENTS: BALLAST FACTOR EQUAL OR GREATER THAN 0.88 BALLAST CREST FACTOR LESS THAN 1.5. TOTAL HARMONIC CURRENT DISTORTION LESS THAN 20%. POWER FACTOR GREATER THAN 90%. 5 YEAR MINIMUM WARRANTY CERTIFIED AS COMPLYING WITH THE CALIFORNIA ENERGY COMMISSION STANDARDS CKT 2 14 14 B DUSK ON / TIME OFF / TIME ON / DAWN OFF / (SELECTED DAYS) PROJECT NAME C NO NC N DRAWING STATUS PLAN CHECK B2 4. 14 A A A e XE E +84 e D EXTERIOR LIGHTING CONTROLLER (ELR) a b c d A B PP e PANEL"B" XE B4 VIA ELR eC C s C e C e s s s e e e FIXTURE PERFORMANCE APPEARANCE CONSTRUCTION MATERIALS HOUSING DIMENSIONS INCLUDING DEPTH FINISH CORROSION AND VANDAL RESISTANCE WHERE APPLICABLE E s s B ANY SUBSTITUTIONS FOR THE FIXTURES SPECIFIED WILL BE CHECKED FOR EQUIVALENCE BASED ON THE FOLLOWING CRITERIA AS A MINIMUM: REVISIONS Sym. Description Date 1 2 3 4 +84 D SCALE: NONE 3 SUBMIT DETAILED INFORMATION REGARDING ANY PROPOSED SUBSTITUTION INCLUDING PHOTOMETRIC DATA AND SHOP DRAWINGS. THE ENGINEER RESERVES THE RIGHT TO REQUIRE THE SUBMISSION OF FIXTURE SAMPLES WHERE APPEARANCE, QUALITY, OR PERFORMANCE IS CRITICAL. EXTER. LIGHTING CONTROL (ELC) WIRING DIAGRAM 5 6 7 8 6. LAMP MODEL NOS SHOWN ARE FOR SYLVANIA. ACCEPTABLE ALTERNATE MANUFACTURERS ARE G.E. AND PHILLIPS. H.MAURO Drawn By SCALE: 1/8"=1'-0 2 ELECTRICAL LIGHTING PLAN Checked By Scale PRELIMINARY NOT FOR CONSTRUCTION ELECTRICAL ENGINEER 317 Third Street, Suite 11 Eureka, CA 95501 (707)445-2163 tel (707)445-2426 fax AS NOTED DPA11YIHA1 Job No. SHEET No. E-3
© Copyright 2024