WSW Sample cooler WSW Sample cooler For High Viscosity/low

WSW sample cooler
WSW Sample cooler
For High Viscosity/Low
Pressure Drop Service
Efficient sample cooling for
high viscosity liquids and slurries
Features
Description
 Fully drainable helical coil
The WSW series sample cooler is designed for use in
applications where drainability is critical but efficiency
cannot be compromised. Its larger diameter sample
tube makes it especially useful for high viscosity liquids
and slurries. Optimal service for flows below 3000 cc/
minute for single phase heat transfer. Standard tube
side material is 316/316L stainless steel.
 Low pressure drop
Performance Curve - Water
Model WSW-8222
Surface Area 2.5 Ft.2 [0.23 m2]
12 GPM [45 L/min] Cooling Water at 95oF [35oC]
7 PSI [0.48 Bar] Pressure Drop
su
re
(P
SI
)
0o
F
15
20
0.4
10
10
0.2
40
30
Dr
op
50
20
oF
0
30
o )
9C
(14
0.6
o C)
3
o F (9
200
5
Tem
Inlet
1 PSI = 0.069 Bar
Approach Temperature (oC)
Approach Temperature (oF)
es
Pressure Drop (PSI)
Pr
)
e
40
60 o
C)
pl
(2
25
0
(2
04 o
C
Sa
m
0o
F
50
NOTE: Not recommended for
steam condensing service. See
TLR, FLR, FXR series sample
coolers for steam applications.
o C)
o F (66
p. 150
0
0.8
400
800
0.1
40
0.2
80
1200
0.3
120
160
1600
CCM
0.4
200
2000
0.5
0.6
GPM
240
Lbm/Hr
Flow Rate
www.sentry-equip.com
2400
280
2800
0.7
320
360
3200
0.8
400
4.7 Rev. 7 09/13
Specifications – WSW Series
Tube
ShellPart
Model No.
Shell Design
Tube DesignMaterialMaterialArea
Weight
Number
WSW-8222
400 psi @ 350ºF
27 bar @ 177ºC
1200 psi @ 650ºF 82 bar @ 343ºC
304 SS
316/316L SS
1/2" O.D. x 0.035"AW
2.5 ft2
0.23 m2
25 lbs
11.5 kg
7-00712A
WSW-8222U
400 psi @ 350ºF
27 bar @ 177ºC
1200 psi @ 650ºF 82 bar @ 343ºC
304 SS
316/316L SS
1/2" O.D. x 0.035"AW
2.5 ft2
0.23 m2
25 lbs
11.5 kg
7-00712G
NOTE:
•
U in model number denotes ASME stamped model.
•
Canadian Registration Number available for ASME models only. Consult factory for CRN and other options and information.
•
Vessels are exempt from CE marking per PED 97/23/EC, TÜV. Vessels are below or equal to the limits set forth in Article 3, Sections 1.1, 1.2, 1.3 and Section 2 as
applicable, and are designed and manufactured in accordance with sound engineering practice (meets the general requirements of the ASME Section VIII, Division 1,
Boiler And Pressure Vessel Code). Nameplate will bear the name of Sentry Equipment Corp and safety instructions will be included per Article 3, Section 2.
It is solely the responsibility of the end-user, through its own analysis and testing, to select products and materials suitable for their specific application
requirements, ensure they are properly installed, safely applied, properly maintained, and limit their use to their intended purpose. Improper selection,
installation, or use may result in personal injury or property damage.
SENTRY EQUIPMENT CORP
For further information, contact:
966 Blue Ribbon Circle North
Oconomowoc, WI 53066 USA
Tel: 262-567-7256 • Fax: 262-567-4523
E-mail:
sales@sentry-equip.com
Website:
www.sentry-equip.com
© Sentry Equipment Corp 2010
4.7 Rev. 7 09/13