Embracing Challenge Gas Sample Probe Series SP® Version SP3100V and SP3100 for sampling from zones with explosive gas SP3100V/RS/HEX4-135 resp. 180 Special Features Approval according to ATEX for sam- pling from Ex-zone 0, 1 and 2 Approval according to ATEX for mount- ing in Ex-zone 1, 2 or 21, 22 Optimum operational reliability Universal applicability Adaption to nearly all process condi- tions due to its compact and modular design Easy mounting and maintanance Small volume, fast response time Application The M&C sample probes version SP3100V and SP3100 are used for continuous extraction of explosive gases (Ex-zone 0, 1 and 2) from dust loaden, high temperature and/or humid processes. The probes can be mounted in Ex-zone 1, 2, 21 and 22. Both versions differentiate only in the sealing material of the filter housing. Version SP3100V has got a sealing out of FPM for types which are heated up to max.185°C and version SP3100 has got a sealing out of graphite for all versions heated up to more than 185 °C. Description The sample probes are designed for easy installation, reliable operation and troublefree maintenance. They are versatile in application and depending on the task to be performed, various pre-filters series V12 or V20 with integrated volume displacer, optional with extension tubes (see page 4 and data sheet 2-1.1.0.8), not included in the scale of delivery, can be simply screwed into the mounting flange of the basic probe. For error control the sample gas flow rate has to be monitored externally. This M&C stainless steel or ceramic filter element with a large surface and high capacity is located in the external housing. The design offers little or no stagnant space outside the process. The probe housing is covered with a protection shield which is part of the Ex-approval. The probes are designed in such a way that changing the filter element is possible without the use of tools. In this operation, neither the sample probe tube nor the sample line need to be removed, thus avoiding contamination of the clean gas path and maintaining the integrity of the system. The temperature control of the M&C-probes version SP3100(V) can be done by three different heater types. The first possibility is a self-regulating heater version HEX4-135 or HEX4-180 (see data sheet 2-3.2) for Ex-zone 1 and 21, for gas sampling from zone 0, 1 or 2. In dependence on the ambient temperature and the heater type, the min. temperature in the probe is 90°C resp. 120°C, the max. temperature is 120°C resp. 160°C. The second possibility is a controlled heating version HEX1-3 for Ex-zone 1, adjustable up to 180 °C and for sampling from Ex-zone 1 or 2. The controller has to be mounted outside the Ex-zone. The third possibility is a controlled heating version HEX1-1 for Ex-zone 1, adjustable up to 180 °C and for sampling from Ex-zone 1 or 2. The controller can be mounted inside the Ex-zone. For back-purging the M&C pre-filter, the option RS is available with mounted buffer vessel triggered by an explosion-proof solenoid valve. With the mounted option for back-purging type RS, gas can be sampled from zone 1 and 2. The back-purge pressure has to be monitored externally and has to be min. 1 bar higher than the process pressure. For the pressure control while back-purging, a corresponding special valve is mounted in the sample gas outlet. Thus an additional solenoid valve to shut off the sample gas outlet is not necessary. The back purge inlet is shut off by a check valve. When sampling from Ex-zones, back purging is only allowed with a gas suitable for the sampling point. The special design of the optional heating of the M&C-probes version SP3100(V) permits controlled heating of the complete filter housing, including the mounting flange. This ensures reliable operation external to the process preventing the temperature falling below the dew-point. Technical specifications and illustrations are without obligation, subject to modifications. 10.04/11.12 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 2.10 Technical Data Gas sample probe type Part No. Weather protection shield Filter housing material Sealing materials Probe flange sealing material Pre-filter / sample tubes Sample pressure max. Ambient temperature Permissible process gas temperature Filter chamber volume Filter element, porosity Sample gas outlet connection Connection gas outlet at option RS Mounting flange Weight Marking Marking with option RS Option back purge unit type RS Part No. Power supply Electrical connection Marking Connection Max. back purge pressure Volume buffer vessel Ambient temperature Option heating type HEX4 Part No. Mounting controller Control Power supply Electrical connection Marking Case protection Power Max. temperature Min. temperature Ambient temperature Low temperature alarm contact Option heating type HEX1 Part No. Mounting controller Control Power supply Electrical connection Marking Power Case protection Temperature Ambient temperature Low temperature alarm contact SP3100V (up to 185 °C) SP3100 (more than 185 °C) 20S5605 20S5600 yes Stainless steel 316 / 316Ti Graphite, FPM Graphite Graphite optional, see data sheet 2-1.1.0.6 and 2-1.1.0.8 0,5-6 bar abs -20 °C to +60 °C depending on the temperature class, however max. 200°C at the probe entry 120 cm3 F-3SS150= stainless steel*, 3 micron S-2K150= ceramic**, 2 micron 1x 1/4“ NPTi for max. 8mm-tube connectors 6 mm Swagelok connector DN65 PN6, FormB, SS316Ti* >DN or ANSI possible** 7 kg II 1G/2GD -20°C ≤ Ta ≤ +60°C EXAM BVS 04 ATEX H 045X II 2G/2GD -20°C ≤ Ta ≤ +60°C EXAM BVS 04 ATEX H 045X RS 20S5560 (a) 230V 50/60Hz 9W or 115V 50/60Hz 9W (a) cable 3x1mm2 II 2GD EEx m II 135°C G1/2” at the buffer vessel 6 bar abs 2 liters -20°C to 60°C HEX4-135 HEX4-180 20S5510 20S5520 in the Ex-zone 1, 2, 21, and 22 self-regulating 115V - 230V 50/60Hz cable gland, terminal range 7 - 12mm, terminals max. 4mm2 II 2 G EEx em T3..T4 / II 2 D IP66 135°C...180°C EXAM BVS 04 ATEX E 253 IP66; EN60529 400W 120 °C 160 °C 90 °C 120 °C -20 °C to +60 °C <60°C, 1 contact MC-NO, 230V 1,5A AC, 0,5ADC <100°C, 1 contact MC-NO, 230V 1,5A AC, 0,5ADC HEX1-3 20S9037 (a) outside the Ex-zone electronic 230V 50/60Hz or 115V 50/60Hz (a) 3 x 1,5mm2 II 2 G EEx d ib IIC T3*, other temperature classes on request 400W IP54; EN60529 0 - 180 °C T3 or 0 - 135 °C T4 -20 °C to +40 °C <120°C, 1 change-over contact, 230V 1,5AAC, 0,5ADC * Standard, ** optional 2.10 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 Technical specifications and illustrations are without obligation, subject to modifications. 10.04/11.12 Technical Data Gas sample probe type Option heating type HEX1 Part No. Mounting controller Control Power supply Electrical connection Marking Power Case protection Temperature Ambient temperature Low temperature alarm contact Option 2-way-ball valve in the probe entrance Part No. Operating temperature Option 2/3-way-ball valve in the probe entrance Part No. Backflush / Test gas connection Operating temperature Option pneum. drive for ball valve /VA o. /3VA Part No. Connection control air Pressure control air SP3100V (up to 185 °C) HEX1-1 20S9038 (a) inside the Ex-zone 1, 2 electronic 230V 50/60Hz or 115V 50/60Hz (a) 3 x 1,5mm2 SP3100 (more than 185 °C) II 2 G EEx d e ib IIC T3*, other temperature classes on request 400W IP54; EN60529 0 - 180 °C T3 or 0 - 135 °C T4 -20 °C to +40 °C <120°C, 1 change-over contact, 230V 1,5AAC, 0,5ADC /VA 20S9050 -20°C up to +185°C /3VA 20S9325 6mm tube -20°C up to +185°C MS1 20S9055 G1/4” i 5-10 bar Temperature class Option second sample gas outlet Part No. Connection T4 /2X 20S9015 1/4” NPT i Option spun glass cartridge Part No. Material /FW 20S9047 SS316Ti, Novapress 20S9046 SS316Ti, Graphite * Standard, ** optional Differential pressure and T90-time ∆P and T90 at flow of: ∆P with new filter element F-3SS150 ∆P with new filter element S-2K150 T90-time for SP3100 without tube Technical specifications and illustrations are without obligation, subject to modifications. 10.04/11.12 100 0,006 0,003 6 200 0,012 0,005 3,5 500 0,040 0,02 1 1000 0,110 0,058 <0,5 1500 0,215 0,135 <0,5 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 Nl/hr bar bar s 2.10 HEX4 140 440 RS 270 40 Dimensions SP3110(V) basic version with option back purging type RS and heating type HEX4 360 340 207 200 133 407 540 Dimensions in mm Option heating HEX1-1 Controller Scale 1 4 2 3 N N 1 X1.1 6 3 4 2 5 3 PA/PE X2 1 2 470 2 4 190 X1 L1 1 Limiter Reset 210 Dimensions in mm 2.10 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 Technical specifications and illustrations are without obligation, subject to modifications. 10.04/11.12 Dimensions Option heating HEX1-3 160 130 Übertemperatur H2 X2: EExi TA- Betrieb N1 (N2) Heizkreis AUS EIN V1 S1 230 230 H1 Netz AUS EIN X1: EExe Q1 X2 450 X1 Ex-area Zone 1 Non-hazardous area Dimensions in mm Options pre-filter and extension tubes Optionen Stainless steel pre-filter with volume displacer, length 220mm, 46mm o.d., filter porosity 2µm,temperature max. 600°C, material SS316 Hastelloy pre-filter with volume displacer, length 220mm, 46mm o.d., filter porosity 2µm, temperature max. 900°C, material Hastelloy-C Stainless steel pre-filter with volume displacer, length 520mm, 60mm o.d., filter porosity 2µm, temperature max. 600°C, material SS316 Hastelloy pre-filter with volume displacer, length 520mm, 60mm o.d., filter porosity 2µm, temperature max. 900°C, material Hastelloy-C Hastelloy pre-filter with volume displacer, length 520mm, 60mm o.d., filter porosity 0,5µm,temperature max. 900°C, material Hastelloy-C Stainless steel pre-filter with volume displacer, length 300mm, 31mm o.d., filter porosity 2µm, temperature max. 600°C, material SS316 Extra charge for extension of insitu stainless steel filter V20-3 or V20-4 for each 100 mm further length (from standard length 300mm to .... mm), max. 1000 mm total filter length, material: SS316.········· Backflushable hose pre-filter with internal support tube, length: 400mm, 40mm o.D., filter porosity 15µm,temperature max. 200°C, material PTFE, SS316 Insitu ceramic filter tube in double-layer version for high blow back efficiency, with volume displacer, length 500mm, 40mm o.d., filter porosity 1µm, temperature max. 1000°C, material ceramic, SS316, connection G3/4" Extension tube for V20.. with internal volume displacer , length 500mm, temperature max. 600°C, material SS316 Extension tube for V20.. with internal volume displacer , length 1000mm, temperature max. 600°C, material SS316 Extension tube for V20.. with internal volume displacer , length 1500mm, temperature max. 600°C, material SS316 Version V20-0 Part No. 20 S 9105 V20-0/HC 20 S 9115 V20-1 20 S 9145 V20-1/HC 20 S 9155 V20-1/HC 20 S 9156 V20-3 20 S 9300 V20-3 20 S 9310 V20-T 20 S 9315 V12-1A-1 20 S 9559 Vm500 Vm1000 Vm1500 20 S 9165 20 S 9170 20 S 9175 For choosing the adequate pre-filter see data sheet 2-1.1.0.8 as well Technical specifications and illustrations are without obligation, subject to modifications. 10.04/11.12 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 2.10 Options sample tubes Options Version Part No. Length 1m, material SS316Ti, temperature max. 600 °C SP2000/SS 20 S 9065 Length 1m, with volume displacer, material SS316Ti, Temperatur max. 600 °C SP2000/SS-Vm 20 S 9067 Length 1m, material Hastelloy-C, temperature max. 900 °C SP2000/HC 20 S 9090 Length 1m, material Kanthal, temperature max. 1300 °C SP2000/KA 20 S 9080 Length 1m, material Incoloy 956, temperature max. 1200 °C SP2000/IC 20 S 9072 For choosing the adequate sample tube see data sheet 2-1.1.0.6 as well Temperature classes for sampling from Ex-zone 0 Type SP3100V II 1 G / 2 GD T6 Max. process gas temp. (°C) at the probe entry ≤ 68 SP3100V II 1 G / 2 GD T5 ≤ 80 80 SP3100V II 1 G / 2 GD T4 ≤ 108 108 II 1 G / 2 GD T3 ≤ 160 160 II 1 G / 2 GD T2 ≤ 200 200 SP3100V Possible Options /HEX4.. SP3100 Marking Temperature class Max. surface temperature (°C) 68 Temperature classes for sampling from Ex-zone 1 or 2 Type Possible Options Marking Temperature class SP3100V II 1 G / 2 GD T6 Max. process gas temp. (°C) at the probe entry ≤ 80 Max. surface temperature (°C) SP3100V II 1 G / 2 GD T5 ≤ 95 95 80 SP3100V /RS, /HEX4-135 II 1 G / 2 GD T4 ≤ 130 135 SP3100 /HEX4-180 II 1 G / 2 GD T3 ≤ 195 195 SP3100 /RS, HEX1.. II 2 G / 2 GD T3 ≤ 195 195 SP3100 /RS II 2 G / 2 GD T2 ≤ 200 200 2.10 M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111 Technical specifications and illustrations are without obligation, subject to modifications. 10.04/11.12
© Copyright 2024