SimFlex TM 30-100 30-120 32-120 40-100 40-120 40-140 50-80 50-90 50-100 50-140 65-90 65-120 80-120 A Montage og brugsvejledning............... 2 DK Installation och skötsel........................... 5 SE Installation guide...................................... 8 ENG Einbauanleitung........................................... 11 DE Montage og brugsvejledning SimFlex Overensstemmelseserklæring: T.Smedegaard A/S erklærer, at disse produkter opfylder følgende EU-direktiver 89/392/EWG (EEC), 89/336/EWG (EEC), 73/23/EWG (EEC)EN 809, EN 12100/1, EN 12100/2, EN 60 335-1, EN 60 335-2-51, EN 50 081-1, EN 50 082-1 Tommy Andersen. T.Smedegaard A/S 57-59 Sydvestvej, DK-2600 Glostrup Denmark Denne montagevejledning giver de grundlæggende instruktioner i, hvad der skal tages hensyn til med henblik på installation, betjening samt vedligeholdse af pumpen. Det er derfor nødvendigt, at vejledningen læses af den for produktet ansvarshavende, før montage og ibrugtagning. Samt at den efterfølgende er tilgængelig på det sted, hvor pumpen er installeret. Det er ikke kun afsnittet om sikkerhed, man skal være opmærksom på, men også den øvrige, i denne vejledning, beskrevne information. 2 DK Anvendelse SimFlex cirkulationspumperne anvendes i forbindelse med alle former for varmeanlæg. Pumpen har en avanceret regulering, som minimerer pumpens strømforbrug ved automatisk at tilpasse pumpens ydelse til anlæggets behov (se også afsnittet “Regulering af pumpens kapacitet”). Dette giver udover store elektriske besparelser, også store komfortmæssige fordele i form af reduceret støjniveau i installationen. Pumpemedie Rene, tyndtflydende ikke-aggressive, -brandfarlige og -eksplosive væsker uden indhold af faste bestanddele eller fibre. Kølevæsker uden indhold af mineralsk olie. Kinematisk viskositet: Max.10 mm²/s. En højere viskositet, kan forårsage en forringet automatisk reguleringsfunktion. De viste kapaciteter på databladene er målt i vand ved ν=1mm²/s ved 20ºC. Kan anvendes med vand med urenhedsgrad på op til 5mg/dm³. Bemærk: Hvor der er tale om andre pumpemedier end vand, anbefales De at kontakte T. Smedegaard A/S eller den regionale importør, da pumpens karakteristik i nogle tilfælde ændres. Tekniske data Elektriske data: Se pumpeskilt Serie nr.: Se pumpeskilt Max. arbejdstryk: 10 bar (1000 kPa) Min. tilløbstryk ved 82°C: 0,5 bar (50kPa) (0,8 bar for 65-120 og 80-120) Min. tilløbstryk ved 95°C: 1,5 bar (150 kPa) Luftbåret lydtryksniveau 30-120 op til 40-140: 50-80 op til 80-120: I henhold til EN 12639 For at undgå kondens i klemkassen, skal pumpemediet altid være højere end omgivelsestemperaturen. SimFlex type: 30-100, 30-120, 32-120, 40-100, 40-120, 40-140, 50-80, 50-90, 50-100 50-140, 65-90, 65-120, 80-120 Medie temp. maks. [°C] Omgivelses temp. maks. [°C] 110 30 90 40 90 30 70 40 Minimum vand temperatur: +15°C Minimum vand temperatur for koldvandsmodel: -5°C Max. 35 dB(A) Max. 50 dB(A) Sikkerhed - Den elektriske installation af pumpen skal foretages efter gældende regulativer. - SimFlex pumper skal altid jordforbindes - Pumpens overflade kan være varm. - I forbindelse med udluftning af pumpen (fig.3) kan der forekomme mindre udslip af varmt vand eller damp! Udannelse og træning Personale for udførelse af vedligeholdse, inspektion samt installation skal have de nødvendige kvalifikationer. Opfyldelse af ovennævnte samt at personalet har læst og forstået denne vejledning, påhviler den for produktet ansvarshavende. Installation 1) Pumpen skal altid installeres med motoraksel vandret (horisontalt) (fig. 1). Pumperetningen er vist med en pil på pumpehuset. 2) Hvis det er nødvendigt at dreje motoren, skal man være opmærksom på, at O-ringen mellem pumpehus og motor sidder korrekt ved fastspænding i ny position. 3) Vær opmærksom på, at der ikke er for stor “spænding” i rørsystemet, og at dette er fastgjort (understøttet). Endvidere bør undgås skarpe “knæk” i nærheden af pumpen. 4) Hvis pumpen monteres i et lodret system, bør pumperetningen vælges opad. Ved nedadgående pumperetning kan evt. luft i systemet have svært ved at passere pumpen. 5) Pumpen må ikke gennem længere tid køre mod lukket ventil. Max 1 min. 6) For at undgå urenheder i pumpen, bør den aldrig monteres på det laveste punkt i anlægget. 7) For at lette en evt. servicering af pumpen er det altid en fordel at montere afspærringsventiler før og efter denne. 8) Anlægget bør altid skylles grundigt igennem for at fjerne diverse slagger og fremmedlegemer m.m. Elektrisk tilslutning Elektriske data aflæses på pumpeskiltet. Pumpen behøver ikke motorværn men skal tilsluttes jord. Det fremgår af klemkassen hvordan kablerne tilsluttes. (fig. 2) Udluftning Når pumpen er installeret, og der er tryk på pumpen og anlæget skal pumpe og anlæg udluftes grundigt inden pumpen sættes i drift. Udluftning sker ved at løsne skruen som findes midt på pumpeskiltet (fig. 3). Udluftningen skal gentages indtil al luften er ude af systemet. Udluftning sker bedst når pumpen står trin 4. Regulering af pumpens kapacitet Pumpen kan reguleres på to måder. • Elektronisk reguleret kapacitet som kontinuerligt tilpasses efter anlæggets behov (auto). • Fast indstillet kapacitet som anvendes i anlæg med konstant varmebehov (1-4). 3 DK Indstillingsmuligheder ved elektronisk regulering Normalindstilling som dækker ca. 90 % af alle installationer. Fabriksindstilling Automatisk reguleret kapacitet som Reduceret pumpetryk garanterer til anlæg med lille energibesparelse trykfald. og øget komfort i anlæg med variabelt behov Forhøjet pumpetryk til anlæg med højt trykfald (f.eks. anlæg med gulvvarme). IInstallationsmuligheder med faste hastigheder 1-4 trin.1 - Til mindre anlæg 4 - Til større anlæg, eller ved udluftning. Fast hastighed til systemer med konstant behov. Kontrollamper SimFlex pumpen er udstyret med to kontrollamper på klemkassen for at indikere pumpens driftsstatus. Når pumpen er tilsluttet, lyser den grønne lampe. I tilfælde af, at pumpen er blokeret, eller hvis der er fejl i elektronik lyser den røde lampe. Pumpen prøver selv at resætte sig selv et par gange. Efterfølgende kræves det at man slukker pumpen minimum et minut. (fig.2). Kontrollamper Beskrivelse Intet lys Ingen strøm på pumpen Grøn lampe lyser Der er tilsluttet strøm Rød lampe lyser Generale fejl. (Se Fejlmeldinger) Røde lampe blinker Start-Stop frakoblet hurtigt. (Se ekstern start-stop) Generelt For at optimere energibesparelsen har alle SimFlex pumper indbygget trykfaldskompensering. Dette indebærer, at pumpen kompenserer for øget trykfald i rørsystemet når flowet øges i anlægget (fig. 4). Ved hjælp af den røde dip switch på printet, kan man enten vælge at styre pumpen manuelt eller eksternt. Det vil sige at når pumpen køres manuelt, styres hastighederne ved hjælp af drejeknappen. Og når den styres eksternt, styres den analogt via et 0-10V signal.Dip switchen har følgende betydning: ON= Eksternstyring OFF= Manuelstyring Kontakt 2 er ikke aktiv. 1 2 (fig. 2) NO Analog 0-10 Volt SimFlex pumpen kan styres trinløst analogt med et 0-10V signal. 0V = Min. hastighed 10V = Max. hastighed (fig. 2) Fejlmeldinger I tilfælde af fejl på pumpen, indikeres dette igennem et signal i den røde lampe. Hvert minut blinker lampen et antal gange for at indikere årsagen til fejlen Antal blink Fejl 1 For høj elektronik temperatur 2 For høj motor temperatur 3 Overbelastning 4 Overstrøm 5 Hastigheds problem 6 Spændingfejl (for høj /-lav) (Uanset fejl, forsøger pumpen at opretholde drift) Se oversigt over fejl på side 14 Ekstern Start-Stop SimFlex pumpen har en ekstern start-stop funktion. Der skal være tilsluttet ”lus” i RUN kontakten før den kan sættes i drift. Hvis et af stikkene er frakoblet, stopper pumpen og den røde diode vil blinke hurtigt. (fig. 2) 1 2 4 DK Alarm relæ SimFlex pumpen har et fejlrelæ. Relæet har både en NC og en NO udgang. (se også fig. 2). Det trækkes kun efter at den elektroniske styring ikke har været i stand til at rette fejlen . Dvs. at, den røde diode kan godt blinke uden fejl relæ er trukket Indstilling foretages ved at dreje på den blå knap som findes på klemkassen. NO Service / vedligeholdelse Smedegaard SimFlex er en vedligeholdelsesfri pumpe som kører i mange år i et rent system. Hvis rotoren sidder sig fast, kan dette være fordi pumpen har stået stille i en længere periode, eller fordi der har dannet sig urenheder. Rotoren kan frigøres ved at fjerne luftskruen i midten af pumpeskiltet og dreje på rotoren med en skruetrækker, indtil den kan køre fri. Bemærk: alle indgreb i pumpens interne elektronik må kun foretages af Smedegaard eller et dertil autoriseret service værksted. Installation och skötsel SimFlex KONFORMITETSDEKLARATION T. Smedegaard A / S intygar härmed att dessa produkterna är i överensstämmelse med: Tommy Andersen. T.Smedegaard A/S 57-59 Sydvestvej, DK-2600 Glostrup Denmark 89/392/EWG (EEC), 89/336/EWG (EEC), 73/23/EWG (EEC)EN 809, EN 12100/1, EN 12100/2, EN 60 335-1, EN 60 335-2-51, EN 50 081-1, EN 50 082-1 Denna instruktion ger en vägledning i vad man skall tänka på med hänsyn taget till installation och drift av pumpen. Det är därför viktigt att instruktionen läses av installatören före montage och idrifttagning. Det är inte bara avsnittet om säkerhet man skall vara uppmärksam på, utan också det övriga i denna instruktion. Användning SimFlex cirkulationspumpar används i värmecirkulerande system. Pumpen har en avancerad reglering som minimerar pumpens strömförbrukning genom att alltid hålla rätt tryck i anläggningen trots varierande flöde. (Se också avsnittet ”Reglering av pumpens kapacitet”) Detta ger stora elektriska och termiska besparingar, men också stora komfortmässiga fördelar som reducering av ljud i anläggningen. Pumpmedie Rena, tunnflytande icke aggressiva och icke explosiva vätskor utan innehåll av fasta partiklar och fibrer. Kylvätska utan innehåll av mineralolja. Kinematisk viskositet: Max. 10 mm²/s En högre viskositet påverkar den automatiska regleringen. Kapaciteten i databladen är mätt vid v=1mm²/s och 20°C. Pumpen klarar föroreningar upp till 5mg/dm³. Obs: När det gäller andra pumpmedier än vatten går det bra att kontakta VM Pumpar AB. Tekniska data Elektriska data: Se pumpskylt Serienummer: Se pumpskylt Max. arbetstryck: 10 bar (1000 kPa) Min. tilloppstryck vid 80°C: 0,5 bar (50 kPa) (0,8 bar för 65-120 och 80-120) Min. tilloppstryck vid 95°C: 1,5 Bar (150 kPa) Luftburen Ljudnivå 30-120 upp till 40-140: 50-80 upp till 80-120: I enlighet med EN 12639. För att undgå kondens i kopplingsboxen, skall pumpmediet alltid ha en högre temperatur än omgivningen. SimFlex typ: 30-100, 30-120, 32-120, 40-100, 40-120, 40-140, 50-80, 50-90, 50-100 50-140, 65-90 65-120, 80-120 Mediatemp. max.: [°C] Omgivningstemp temp. max.: [°C] 110 30 90 40 90 30 70 40 Minsta vattentemperatur: 15°C Minsta vattentemperatur för kallvatten modell: -5°C Max. 35 dB(A) Max. 50 dB(A) 5 SE Säkerhet - Den elektriska installationen skall göras enligt gällande lokala föreskrifter. - SimFlex pumpar skall alltid anslutas till jord. - Pumpens överdel kan vara varm! - När man luftar pumpen (fig.3) kan det förekomma mindre spill av varmt vatten! Behörighet Personal för underhåll, kontroll och installation måste ha nödvändig behörighet för att utföra arbetet. Ovan nämnda måste följas och personalen ska ansvara för att ha läst och förstått denna instruktion. 6 SE Installation 1) Pumpen ska alltid installeras med pumpaxeln horisontellt (se fig. 1). Flödesriktningen visas med en pil på pumphuset. 2) Om det är nödvändigt att lossa drivsidan ska man noga kontrollera att O-ringen mellan pumphus och motor sitter ordentligt efter montering i ny position. 3) Se till att inga spänningar finns i rörsystemet, samt att det är ordentligt fastsatt. Skarpa böjar bör undvikas i pumpens närhet. 4) Då pumpen monteras i ett lodrätt system bör man välja uppåtgående flödesriktning. Vid nedåtgående flödesriktning kan eventuell luft i systemet ha svårt att passera pumpen. 5) Pumpen får inte köras mot stängd ventil. Max 1 min. 6) Undvik att montera pumpen på den lägsta punkten i rörsystemet, för att minska ansamling av föroreningar i pumpen. 7) Avstängningsventiler bör alltid monteras på båda sidor om pumpen. 8) Spola ur systemet noggrant före igångkörning, så att inga föroreningar kan skada eller blockera pumpen. Elektriskt montage El-data avläses på pumpskylten. Pumpen kräver inget externt motorskydd men skall anslutas till jord. Hur man ansluter kablarna visas i kopplingsboxen på pumpen. (fig 2) Luftning När pumpen är installerad och anläggningen trycksatt, skall pump och anläggning luftas grundligt före pumpen startas. Pumpen luftas genom att lossa skruven i mitten av märkskylten (se fig. 3). Det är nödvändigt att upprepa avluftning för att få ur all luft. Avluftningen görs bäst med pumpen inställd på varvtal 4. Reglering av pumpens kapacitet Pumpen kan justeras på två sätt. • Elektroniskt reglerad kapacitet som kontinuerligt anpassar sig efter anläggningens behov (Auto). • Fast inställd kapacitet, som används i anläggningar med konstant belastning eller vid service (1-4). Inställningsmöjligheter vid elektronisk reglering Normal inställning som täcker ca 90% av alla installationer. Fabriksinställning Automatisk reglerad kapacitet som garanterar Reducerat pumptryck, energibesparing till anläggningar och ökad komfort med litet tryckfall. används i anläggningar med variabelt behov. Ökat pumptryck, till anläggningar med stort tryckfall. (t.ex. vid anläggningar med golvvärme) Inställningsmöjligheter för fasta hastigheter 1-4 hastigheter. 1 används till små anläggningar och 4 till stora anläggningar och vid avluftning. Pumpen går med fast hastighet, används vid konstantbehov. Generellt: För att optimera energibesparingen har alla SimFlex-pumpar inbyggd tryckfallskompensering. Detta innebär att pumpen kompenserar för ökat tryckfall i rörsystemet när flödet ökar i anläggningen. (fig. 4.) Alarmrelä SimFlex-pumparna har ett inbyggt larmrelä. Reläet har både NC och NO utgång. (fig. 2) Reläet växlar till larm först efter att pumpens elektronik misslyckats att lösa problemet. Detta betyder att den röda dioden kan blinka trots att det inte är ett larm. Inställningen görs genom att man vrider på den blå ratten som är placerad på kopplingsboxen. Kontrollampor SimFlex-pumpen är utrustad med två kontrollampor i kopplingsboxen för att visa driftstatus för pumpen. När pumpen är ansluten lyser den gröna lampan. Vid fel i pumpens elektronik eller om pumpen är blockerad lyser den röda lampan. Pumpen försöker själv att göra några återstarter, om inte detta lyckas måste man bryta strömmen till pumpen under minst en minut för att den skall återställa sig helt. (fig. 2) Kontrollampor Beskrivning Inget sken: Ingen ström till pumpen Grönt sken: Normal drift Rött sken: Elektronikfel/Blockerad motor Röda dioden blinkar snabbt: Extern start - stopp frånkopplad Felkoder Om elektroniken i pumpen upptäcker ett fel visas detta genom en röd lampa på Med hjälp av dip-switcharna på kretskortet kan man välja om kopplingsboxens baksida. Varje minut pumpen skall styras externt eller internt. I Internt läge används blinkar lampan ett antal gånger och indikerar den blå knappen på pumpen för att antingen ställa in ett önskat ett fel enligt listan nedan. tryck som pumpen skall jobba proportionerligt efter eller 4 Antal blinkningar Felorsaker fasta kurvor. I Externt läge styrs pumpen via en extern 0-10 1 För hög temperatur i elektroniken Volts signal. Dip-switcharna har följande 2 För hög temperatur i motorn funktion: 3 Överlast ON = Extern styrning 4 Överström 1 2 OFF = Intern styrning 5 Hastighet problem Kontakt två används inte. (fig. 2) NO 6 Se felöversikten på sidan 14 1 2 Extern analog 0-10 Volt SimFlexpumpen kan regleras med en extern 0-10 Volts signal. 0V = Min hastighet 10V = Max hastighet (fig. 2) Över/under-spänning (Oavsett fel försöker pumpen att köra) Extern start - stopp SimFlexpumpen har en extern start - stopp funktion. Det skall vara en slutning i RUN kontakt innan pumpen startar. Om det inte är kontakt kommer pumpen att stanna och den röda dioden på pumpen blinka snabbt. (fig. 2) NO Service / underhåll SimFlex pumpen är en underhållsfri pump som i ett rent system fungerar i många år. Om rotorn fastnat kan detta bero på att pumpen varit stoppad under en längre tid och det då samlats föroreningar eller uppbyggnad av magnetit i pumpen. Axeln kan frigöras genom att man tar bort luftskruven i mitten av märkskyllten och sticker in en skruvmejsel och vrider runtaxeln tills den går lätt igen. Notera: Alla ingrepp i pumpens interna elektronik skall göras av en av VM Pumpar auktoriserad verkstad. 7 SE Installation Guide SimFlex DECLARATION OF CONFORMITY T.Smedegaard A/S hereby declare that these products are in conformity with: 89/392/EWG (EEC), 89/336/EWG (EEC), 73/23/EWG (EEC)EN 809, EN 12100/1, EN 12100/2, EN 60 335-1, EN 60 335-2-51, EN 50 081-1, EN 50 082-1 Tommy Andersen. T.Smedegaard A/S 57-59 Sydvestvej, DK-2600 Glostrup Denmark This installation guide gives the basic instructions which are to be observed during installation, operation and maintenance of the pump. It is therefore imperative that this manual is read by the responsible operator prior to the installation and should always be kept available at the site. It is not only the general safety instructions under the ”Safety” section that are to be observed but also the specific information provided throughout this guide. Application The SimFlex circulating pumps are used in all types of heating systems. By use of the advanced internal speed control, the electric automatic regulator adjusts the pump performance according to system needs. This feature gives both great electrical, and thermal savings together with reduced noise level in the installation. 8 GB Pump medium Clean, none aggressive and none explosive fluids without any solids or fibres. Kinematic viscosity: Max. 10mm²/s. Higher viscosity will cause pump to regulate improperly. Capacities shown on the data sheets, are measured with water v =1mm²/s at 20ºC. Suitable for water impurity up to 5mg/dm³. Please note: If any liquid other than water is being pumped, we recommend that you contact T. Smedegaard A/S or one of our representatives, as the pump characteristics may change. Technical data Electrical data: See nameplate Serial No.: See nameplate Max. working pressure:: 10 bar (1000 kPa) Min. static head at 80°C: 0,5 bar (50kPa) (0,8 bar for 65-120 and 80-120) Min. static head at 95°C: 1,5 bar (150 kPa) SimFlex type: 30-100, 30-120, 32-120, 40-100, 40-120, 40-140, 50-80, 50-90, 50-100 50-140, 65-90 65-120, 80-120 Water temp. max. [°C] Ambient temp. max. [°C] 110 30 90 40 90 30 70 40 Minimum water temp.: +15°C Minimum water temp. for cold water model: -5°C Sound pressure level 30-120 up to 40-140: 50-80 up to 80-120 According to EN 12639 Max. 35 dB(A) Max. 50 dB(A) Safety - Pump should be wired according to the existing regulations. - The pump must always be earthed - All the wires must be disconnected before any work is carried out on the pump. - The surface temperature might be hot. - When venting the pump (fig. 3), it could result in a slight escape of hot water or steam! Personnel qualification and training Personnel responsible for operation, maintenance, inspection and installation of the pump must be adequately qualified. The person responsible for the complete installation must ensure that the contents of this manual are fully understood by any personnel working on the system. Installation 1) The pump should always be installed with the pump shaft horizontal (See fig. 1). Direction of flow through the pump casing is indicated by an arrow located on the casing. 2) If terminal box is to be repositioned by rotating the motor, care must be taken to ensure the casing 0-ring is correctly positioned. 3) Ensure pipe work alignment and adequately supported to both the pump and pipe work. Sharp bends should be avoided nearby the pump. 4) If the pump is mounted in vertical pipe work, flow should be upwards. If flow is downwards, an air-vent must be fitted at the highest point before pump suction. 5) Pump should never be allowed to operate against a closed valve for more then a few minutes at the time. 6) To avoid accumulation of impurities in the pump, make sure that it is not mounted at the lowest point in a system. 7) It is recommended that on/off service valves are fitted on either side of the pump. 8) Before installing a new pump the system should be thoroughly flushed to clear any foreign objects that may be in the pipe work. Electrical connection Electrical data is shown on the nameplate. The pump needs no external protection but must be earthed. How to connect the wires can be seen on the terminals of the pump. (See fig. 2) Venting Before start up of the pump, fill the system and vent the pump thoroughly. Venting can be achieved by loosening the plug positioned in centre of nameplate (See fig. 3). This process should be repeated periodically until all air within the system has been removed. Venting is best done in manual speed 4. Duty Control There are two modes for controlling the pumps. • Controlled to follow a specific defined differential pressure at different flows (auto). • Controlled to follow constant speed for systems with constant demand (1-4). 9 GB Electronic controlled settings Normal setting, to cover app. 90 % of all installations. Factory-setting Auto controlled performance for power savings Reduced differential and extra pressure. For systems comfort where with little resistance. flow demands are changing. Increased differential pressure. For systems with high resistance as radiant floor heating systems. Fixed speed settings 1-4 speeds. 1. for small systems and 4. for large systems or venting General In all SimFlex pumps, PLC is included in the control, meaning that the pump does not follow a constant differential pressure but takes into account the decreasing pressure needs at decreasing flow. This setting is in the auto controlling mode. (fig. 4) By using the red dip switch on the print board, you can either choose to control the pump manually or remotely. In the manual mode you control the speeds by the rotating button. When the pump is controlled remotely, its controlled analogical via a 0-10V signal. The dip switch has the following functions: ON = Remote Control 1 2 OFF = Manual Steering Contact 2 is without function. (fig. 2) Analogue 0-10 Volt The SimFlex can be controlled infinitely variable by analogue signal from 0-10V. 0V= Min. speed 10V= Max. speed (fig. 2) Description No light Main supply switched off Green light Normal operation – power on Red light Error. (See Error Signals) Red light flashes rapidly Remote Start-Stop has been disconnected. (see remote start-stop) Error signals The red light on the back of the terminal box will in case of an error, indicate the type of error detected by the electronics. Approximately, every minute the light will flash a number of times Number of Error flashes 1 Electronics temp too high 2 Motor temp too high 3 Over load 4 Over current 5 Speed Error 6 Voltage error (under or over) (Regardless of fault, the pump will try to maintain operation) See fault list at page 14 Remote Start-Stop SimFlex pump has a remote start-stop function. A cable must be connected to the RUN contact. If a cable should be disconnected, the pump will shut down and the red light will flash rapidly. (see fig. 2) 1 2 GB Signals The SimFlex pumps have two LED’s on the terminal box for status indication. Power to the pump is indicated with a green LED. The red LED will be on if the pump has detected a fault. The pump will try to reset it self a couple of times. Subsequently, it is recommended to switch off the pump for minimum a minute. (fig 2) Signal LED Fixed speed for systems with constant resistance and radiant floor heating systems. NO 10 Error Relay The SimFlex has a fault relay. The relay has both a NC and a NO connecting. (Also See fig. 2.) The relay kicks in after the electronics has failed to solve the problem. This means that the red light could flash, even though the relay hasn’t kicked in. Setting is done via the rotating button on the top of the terminal box. NO Service/Maintenance Smedegaard’s SimFlex range of glandless pumps is virtually maintenance free, and in a well designed system should give many years of trouble free operation. If motor shaft is seized as a result of a long period without use or due to accumulation of impurities, it should be freed. Insert a screwdriver through the venting plughole and into the slot in the end of the shaft and rotate. Note: Any repairs required to the internal electrical parts of the pump, are to be carried out by a Service department approved by T. Smedegaard A/S. Einbauanleitung SimFlex Übereinstimmungserklärung T. Smedegaard A/S erklärt hiermit die Übereinstimmung der 89/392/EWG (EEC), 89/336/EWG (EEC), 73/23/EWG (EEC)EN 809, EN 12100/1, EN 12100/2, EN 60 335-1, EN 60 335-2-51, EN 50 081-1, EN 50 082-1 Tommy Andersen. T.Smedegaard A/S 57-59 Sydvestvej, DK-2600 Glostrup Denmark Diese Anleitung gibt Ihnen wertvolle Hinweise für den Einbau, Betrieb und die Fehlersuche für dieses Produkt. Vor dem Einbau empfehlen wir, diese Anleitung sorgfältig durchzulesen und diese dann nach dem Einbau in der Nähe der Pumpe zu platzieren. Es sind alle Sicherheitshinweise in dieser Anleitung besonders zu beachten. Einsatzgebiet Die SimFlex Umwälzpumpen finden in allen Arten von Heizungsanlagen Verwendung. Mittels einer eingebauten Drehzahlregelung hält die Pumpe die vorbestimmte Förderhöhe bei schwankenden Förderströmen ein (siehe Einzelheiten in der Rubrik "Regelung"). Die wesentlichen Vorteile der elektronischen Regelung sind: Energieeinsparung und Reduzierung von Fliessgeräuschen in der Anlage Fördermedium Reine, dünnflüssige, nicht aggressive und nicht explosive Flüssigkeiten ohne feste oder faserige Fremdkörper. Viskosität: Max. 10 mm²/s. Höhere Viskositäten verursachen, dass die Pumpe nicht mehr richtig regelt. Einsatz der Pumpe ist für Wasserverunreinigungen bis zu 5mg/dm ³ geeignet. Die Kapazitäten (siehe Datenblätter) werden mit Wasser v = 1 mm ² / s bei 20°C gemessen Bitte beachten: Wird ein anderes Fördergut als Wasser gepumpt, empfehlen wir Rücksprache mit T.Smedegaard A/S oder einem Vertreter zu nehmen, da sich die Förderleistungen ändern können. Technische Daten Elektrische Daten: siehe Typenschild Serien-Nr: siehe Typenschild Max. Betriebsdruck: 10 bar (1000 kPa) Min. Anlagendruck bei 80°C: 0,5 bar (50kPa) (0,8 bar für 65-120 und 80-120) Min. Anlagendruck bei 95°C: 1,5 bar (150 kPa) SimFlex Typ: 30-100, 30-120, 32-120, 40-100, 40-120, 40-140, 50-80, 50-90, 50-100 50-140, 65-90 65-120, 80-120 Wassertemp. max. (°C) UmgebungsTemp max. (°C) 110 30 90 40 90 30 70 40 Minimum Wasser Temp.: +15°C Minimum Wasser Temp. für Kaltwasser-Modell: -5°C Luft-Schalldruckpegel 30-100 bis zu 40-140: 50-88 bis zu 80-120: Nach EN 12639 Max. 35 dB(A) Max. 50 dB(A) 11 DE 12 DE Sicherheitshinweise - Die Pumpe muss durch eine Fachperson, entsprechend den örtlichen Vorschriften, angeschlossen werden! - Die Versorgungsspannung muss vor jeder Arbeit an der Pumpe abgeschaltet sein! - Die Erdklemme der Pumpe muss mit dem Erdleiter verbunden werden. - Die Gehäusetemperatur kann sehr hoch sein! -Beim Entlüften der Pumpe (fig. 3) kann etwas heisser Dampf oder Wasser austreten! Personalqualifikation und Schulung Das für Betrieb, Wartung, Inspektion und Einbau verantwortliche Personal muss ausreichend qualifiziert sein. Der für die gesamte Anlage Verantwortliche muss sicherstellen, dass der Inhalt dieser Anleitung von dem an der Anlage arbeitenden Personal verstanden wird. Installation 1) Die Pumpe sollte stets mit waagerechter Lage der Welle eingebaut werden (fig. 1). Die Durchflussrichtung ist auf dem Pumpengehäuse durch einen Pfeil angegeben. 2) Der Steuerungskasten kann durch Drehen des Motorkopfes anders angeordnet werden. Es ist darauf zu achten, dass sich beim Zusammenbau der O-Ring des Gehäuses in der richtigen Lage befindet 3) Stellen Sie Sicher, dass die Rohrleitungen spannungsfrei verlegt sind. Die Rohre sind so zu befestigen, dass die Pumpe nicht das Gewicht der Rohre trägt. Enge Rohrbogen nahe der Pumpe sollten vermieden werden 4) Wird die Pumpe in einen senkrechten Rohrstrang eingebaut, sollte die Flussrichtung nach oben sein. Ist die Flussrichtung nach unten gerichtet, ist ein Entlüftungsventil an der höchsten Stelle vor dem Saugstutzen der Pumpe einzubauen 5) Die Pumpe sollte nie längere Zeit gegen geschlossene Absperrschieber betrieben werden. Max 1 Min. 6) Um Ansammlungen von Verunreinigungen in der Pumpe zu vermeiden, stellen Sie sicher, dass sie nicht an der tiefsten Stelle einer Anlage eingebaut wird. 7) Es wird empfohlen, Absperrschieber beidseitig der Pumpe einzubauen 8) Nach längeren Stillstandzeiten empfehlen wir, bei einer neu installierten oder revidierten Heizungsanlage nach dem ersten Aufheizen diese zu entleeren, gründlich durchzuspülen und wieder neu zu füllen. Elektrischer Anschluss Die elektrischen Daten entnehmen Sie bitte dem Typenschild. Anschluss der Pumpe (fig. 2). Wenn die Pumpe richtig angeschlossen ist, leuchtet die Grüne LED (fig. 2). Für die Pumpe ist kein zusätzlicher Motorschutz erforderlich, sie muss aber geerdet sein. Entlüftung Die Pumpe ist vor Inbetriebnahme der Anlage zu entlüften. Lösen Sie während dem Lauf der Pumpe die Verschlussschraube (fig. 3). Schliessen Sie die Verschlussschraube wieder. Diesen Vorgang sollten Sie mehrmals wiederholen, bis die im Wasser der Anlage gelöste Luft entwichen ist. Entlüften Sie auf der Manuellen Stufe 4. Regelung Es gibt 2 Regelarten für die Regelung der Pumpe. • Automatische elektronische Regelung • Manuelle Regelung mit 4 Drehzahlstufen Einstellungen mit dem Blauen Drehknopf. Automatische Einstellung Reduzierter Betrieb Sollwertpunkt wird kleiner. Reduzierte Leistung. Normalbetrieb Deckt 90% aller Anwendungen ab.(Werkseinstellung) Automatischer Betrieb für Energieeinsparung und veränderliche Leistungsanforderungen Erhöhter Betrieb Sollwertpunkt wird grösser. Erhöhte Leistung Manuelle Einstellung Manueller Betrieb Leistung in 4 fixen Stufen einstellbar Alarm Relais Die SimFlex hat ein Alarm Relais. Das Relais hat sowohl einen Schliesser wie Öffner Kontakt. (fig. 2). Das Relais schaltet wenn die Elektronik den Fehler nicht beheben kann. Dies bedeutet, dass die rote Kontrollanzeige weiter blinkt, obwohl das Relais nicht geschaltet hat. Betrieb für 4 feste Leistungsbereiche Signale Die SimFlex Pumpen haben zwei LED's am Steuerungskasten für die Betriebsanzeige. Bei Normalbetrieb leuchted die grüne LED. Wenn die Steuerung der Pumpe einen Fehler erkennt leuchted die rote LED. Bei einem Fehler wird die Steuerung mehrmals einen Reset der Pumpe versuchen. Wenn die Pumpe auf Störung bleibt, empfehlen wir diese für mindestens 1 Minute vom Netz zu schalten. (fig. 2) LED-Signal Beschreibung Keine Anzeige Aus - Stromzufuhr ausgeschaltet Grün Ein - Normaler Betrieb Allgemeines Rot Störung - Elektronik Bei allen SimFlex Pumpen ist PLC Regelung einbezogen, was Rot blinkend Start Stop Funktion unterbrochen bedeutet, dass die Pumpenregelung nicht einem konstanten Differenzdruck folgen, sondern bei abnehmendem Druck wird Fehler Signale auch der Durchfluss kleiner. Im Automatik Modus wird die Die rote LED auf der Seite des SteuerungskaPumpe automatisch gesteuert. (fig. 4) sten zeigt bei einem Fehler der Elektronik durch Anzahl blinken die Art des Fehlers. Im Der Steuerungsmodus kann mit dem DIP-Schalter auf der Intervall von ungefähr einer Minute wird der Leiterplatte eingestellt werden. Bei Einstellung Modus auf Fehlercode repetiert Manuell, können Sie mit dem Blauen Drehknopf die Drehzahl Anzahl Fehlerursache der Pumpe manuell regeln. Im Modus Extern gesteuert blinken (Remote Control) kann die Pumpe mit einem externen 1 Elektronik Temperatur zu hoch analogen Signal gesteuert werden. Die 2 Motor Temperatur zu hoch Dip-Schalter hat folgende Funktionen: 3 Motor überlasted ON = Extern gesteuert 1 2 4 Pumpe überlasted OFF = Manuell gesteuert 5 Interner Fehler Steuerung Schalter 2 ist zur Zeit ohne Funktion. (fig. 2) NO 6 Siehe Fehlerliste Seite 14 Wartung / Unterhalt 1 2 Analog 0-10 Volt Die SimFlex kann stufenlos durch ein analoges Signal von 0-10V geregelt werden. 0V = Min. Geschwindigkeit. 10V = Max. Geschwindigkeit. (fig 2) Über- oder Unterspannung Netz (Unabhängig von den Fehlermeldungen wird Pumpenbetrieb versucht) Extern Start-Stop SimFlex Pumpen haben eine Start-Stop Funktion. Ein externes Kabel muss an Klemmen RUN angeschlossen werden. Wenn ein Kabel getrennt wird schaltet die Pumpe ab und die rote LED blinkt schnell. (fig. 2). NO Die Smedegaard SimFlex Umwälzpumpen sind nahezu wartungsfrei. In einem guten System eingebaut, werden diese über Jahre störungsfrei ihren Dienst tun. Wenn die Pumpe längere Zeit nicht im Betrieb war oder das System stark verschmutzt ist, kann der Rotor blockieren. Durch Herausdrehen der Verschlussschraube kann der Rotor mit einem Schraubenzieher deblockiert werden. Achtung: Reparaturen an der Elektronik dürfen nur von einem autorisierten Servicepartner der T.Smedegaard A/S ausgeführt werden. 13 DE 14 Fejl / Problem / Fault / Fehler DK Fejl Pumpen kører ikke og der er ikke lys i pumpen. Årsag Der er muligvis ikke spænding på pumpen, løs jordforbindelse eller en sikring er gået. Løsning Check spændingen på motoren, check jordforbindelsen og check sikringer. Pumpen kører i kort tid når den starter, men stopper næsten umiddelbart efter. Der er ikke noget start signal. Sæt eksternt start-stop lus stik i. Se under overskriften ”Generelt”. Pumpen kører ikke, og pumpen blinker ca. én gang per sekund. Der har været for høj temperatur i elektronikken i Sørg for at medie- og omgivelsestemperaturen flere minutter. overholder de forskrevne temperaturgrænser. Pumpen kører ikke, og pumpen blinker 2 gange per sekund efterfulgt af en kort pause. Pumpen kører ikke og pumpen blinker 3 gange per sekund efterfulgt af en kort pause. Der har været for høj temperatur i motoren i flere Sørg for at medie- og omgivelsestemperaturen minutter. overholder de forskrevne temperaturgrænser. Pumpen har været overbelastet gennem flere Check for urenheder ved pumpens løbehjul. minutter. Pumpen kører op og ned i hastighed, og pumpen blinker 4 gange per sekund efterfulgt af en kort pause. Pumpen kører ikke, og pumpen blinker 5 gange, efterfulgt af en kort pause. Pumpen kører ikke, og pumpen blinker 6 gange, efterfulgt af en kort pause. Pumpen er overbelastet. Check for urenheder ved pumpens løbehjul. Intern fejl i pumpe. Pumpen er udsat for spændinger udenfor de normerede rammer. Kontakt Smedegaard Pumper for information. Se www.smedegaard.dk Sørg for at pumpen er forbundet korrekt og check at spændingen er indenfor de tilladte grænser. SE Problem Pumpen går inte och ingen kontrollampa lyser. Orsak Det är ingen spännig fram till pumpen. Pumpen är fel jordad eller en säkring har gått sönder. Åtgärd Kontrollera spänningen och kontrollera jorden och säkringen. Pumpen startar men går bara en liten stund och stoppar sedan. Pumpen får ingen startsignal. Montera en bygel i de externa start - stop plintarna. Se under avsnittet ”Generellt”. Pumpen går inte och blinkar en gång per sekund. Det har varit för hög temperatur i elektroniken i flera minuter. Kontrollera att vatten och omgivningstemperatur ligger inom föreskrivna temperaturintervall. Pumpen går inte och blinkar 2 gånger och efterföljs av en kort paus. Pumpen går inte och blinkar 3 gånger och efterföljs av en kort paus. Det har varit för hög temperatur i motorn i flera minuter. Pumpen har varit överbelastad i flera minuter. Kontrollera att vatten och omgivningstemperatur ligger inom föreskrivna temperaturintervall. Kontrollera så pumphjulet inte sitter fast. Pumpen går upp och ner i hastighet och blinkar 4 gånger och efterföljs av en kort paus. Pumpen går inte och blinkar 5 gånger och efterföljs av en kort paus. Pumpen går inte och blinkar 6 gånger och efterföljs av en kort paus. Pumpen är överbelastad. Pumpen har utsatts för spänningar utanför det normala området. Kontrollera så pumphjulet inte sitter fast eller är igensatt Kontakta VM Pumpar för mer information. Se www.vmpumpar.se Kontrollera att pumpen är rätt ansluten och att spänningen är inom det rätta gränserna. ENG Fault The pump is not running, and there is no light in the LED. Cause The main supply has been switched off, earthed incorrectly or a fuse has blown. Action Check the main supply, check if the pump has been earthed correctly and check if a fuse has blown. The pump starts up to begin with, but then shuts down almost straight afterwards. Remote Start-Stop has been disconnected. Install the remote Start-Stop plug into inverter. See the heading “General”. The pump is not running, and the LED is flashing approximately once per second. The temperature in the electronics has been too high for several minutes. Check that water and ambient temperatures are within the stated temperature ranges. The pump is not running, and the LED flashes 2 per second followed by a brief pause. The pump is not running, and the LED flashes 3 times per second followed by a brief pause. The temperature in the motor has been too high for several minutes. The pump has been subjected to overloaded for several minutes. Check that water and ambient temperatures are within the stated temperature ranges. Check that there are no impurities at the impeller. The pump performance is fluctuating, and the LED flashes 4 times per second followed by a brief pause The pump is not running, and the LED flashes 5 times per second followed by a brief pause. The pump has been overloaded. Check that there are no impurities at the impeller. Internal error. Contact Smedegaard Pumps for details. See www.smedegaard.co.uk The pump is not running, and the LED flashes 6 times per second followed by a brief pause. The pump has been subjected to voltages outside the normal range. Make sure the pump is connected correctly, and check whether the voltage is within the limits. DE Fehler Pumpe läuft nicht – Keine LED Anzeige. Ursache Hauptschalter ausgeschaltet, Sicherung defekt, Erdleiter falsch oder nicht angeschlossen. Abhilfe Hauptschalter und Sicherung prüfen, Anschluss der Pumpe kontrollieren. Pumpe läuft an und stellt sofort wieder ab. Remote Start-Stop Kontakt wurde entfernt. Verbindungsbrücke der Start-Stop Funktion einsetzen, siehe auch Kapitel “Allgemeines”. Pumpe läuft nicht – LED Anzeige blinkt 1x/sec. Temperatur in der Elektronik für kurze Zeit zu hoch. Prüfen Sie, ob die Wasser-und Umgebungstemperatur innerhalb der angegebenen Temperaturbereiche liegen. Pumpe läuft nicht – LED Anzeige blinkt 2x/sec. (Intervall mit Pause). Pumpe läuft nicht – LED Anzeige blinkt 3x/sec. (Intervall mit Pause). Temperatur im Motor für kurze Zeit zu hoch. Prüfen Sie, ob die Wasser-und Umgebungstemperatur innerhalb der angegebenen Temperaturbereiche liegen. Überlast der Pumpe für kurze Zeit. Prüfen Sie, ob das Laufrad verschmutzt ist. Pumpe läuft unregelmässig – LED Anzeige blinkt 4x/sec. (Intervall mit Pause). Pumpe läuft nicht – LED Anzeige blinkt 5x/sec. (Intervall mit Pause). Pumpe läuft nicht – LED Anzeige blinkt 6x/sec. (Intervall mit Pause). Überlast der Pumpe. Prüfen Sie, ob das Laufrad verschmutzt ist. Interner Fehler Steuerung Kontaktieren Sie eine Smedegaard Gesellschaft. www.smedegaard.dk / www.smedegaard.ch Sicherstellen dass Pumpe richtig angeschlossen ist und die Betriebsspannung stimmt. Internt fel i pumpen Überspannung im Netz (ausserhalb Toleranz). Fig 2. Fig 1. 30-100, 30-120, 32-120, 40-100, 50-80, 50-90 Power L N 40-120, 40-140, 50-100, 50-140, 65-90, 65-120, 80-120 4 2 3 Fig 4. 1 1 2 NO ax oM to M in . 15 Au Aut Red/Rot= Alarm Green/Grün= Power On 55 50 60 12 15 3 5 10 6 9 45 15 40 20 35 30 25 30s. Fig 3. Schweiz Smedegaard AG Industriestrasse 15 CH-5712 Beinwil am See Schweiz Tel: (+41) 62 765 05 00 Fax: (+41) 62 765 05 01 info@smedegaard.ch www.smedegaard.ch Sverige VM Pumpar AB August Barks Gata 25 SE-421 32, Västra Frölunda Sverige Tel. (+46) 31 49 35 80 Fax. (+46) 31 49 35 81 info@vmpumpar.se www.vmpumpar.se Smedegaard reser ve the right to change the product without prior notice and tak e no responsibility f or inaccuracies or mispr ints. United Kingdom Smedegaard Pumps Ltd. 10 Beech Business Park, Bristol Road, Bridgwater, Somerset TA6 4FF, England Tel. (+44) 1278 458 686 Fax (+44) 1278 452 454 info@smedegaard.co.uk www.smedegaard.co.uk 9999999822 • Grafisk tilrettelæggelse og produktion: Grafia.dk. November 2011. Danmark T. Smedegaard A/S Sydvestvej 57-59 DK-2600 Glostrup Denmark Tel: (+45) 43961028 Fax: (+45) 43631766 info@smedegaard.dk www.smedegaard.dk
© Copyright 2024