GC2/GH2/GM2/GS2 Series Dimensions Address: Contact : E-mail : Web : 37-7 Chuo-cho, 2-Chome Meguro-ku, Tokyo 152-0001 Japan Tel: +81-3-37165151 Fax: +81-3-37104552 webtrade@line.co.jp http://www.lineseiki.com 2 0: Terminal Block Input 0: Switch/Open Collector Input 1: Wide Range Voltage Input Reset 0: Remote 1: Remote & Front INPUT GC2 TOTALIZER GH2 HOURMETER 6/8 Digits, 7-Segment LCD 10.6mm (H) 0 - 999999 / 0 - 99999999 Switch / Open Collector Wide Range Voltage GM2 MINUTEMETER WEIGHT WIRING COMPLIANCE 10.6 24.8 29 Terminal No. 1 2 3 4 5 Input 1 2 3 4 5 Wide Range Voltage Input Type Reset Input Vcc 2 3 4 5 Reset GND GND GND 1 GND Vcc GS2 SECONDMETER 6 Digits, 7-Segment LCD 10.6mm (H) 1. Please install the device in the correct panel cut-out size. 2. A gasket is included with the device. Insert the gasket in the device before inserting it in the panel. 3. Insert the mounting clip to the back of the device. 4. Push the mounting clip until it locks the device tightly against the panel. 0.0 - 99999.9 L: < 0.8V H: < 2 - 30V Sink Current: 8 A L:DC / AC 0 - 5V Input Impedance: 300kW H:DC / AC 20 - 250V Gasket Battery Replacement 1 count per 1/10 hour Front Reset Remote Reset Mounting Clip Panel 20Hz (Wide Range Voltage Input Only) 1 count per 1/10 minute 1 count per 1/10 second L: < 0.8V H: < 2 - 30V Sink Current: 8 A L:DC/AC 0 - 5V Input Impedance: 300kW H:DC/AC 20 - 250V 6ms minimum RESET PULSEWIDTH 3.6V 1/2AA Lithium Battery (replaceable), 7 years min. with continuous input at 25°C *The battery life is not a guaranteed value. POWER Electrostatic Discharge: IEC-61000-4-2 8kV NOISE IMMUNITY Electromagnetic Field: IEC-61000-4-3 10V/m EFT/BI/O Leads: IEC-61000-4-4 1.0kV EMI: EN50081-2 EMS: EN50082-2 EMC STANDARD -10 - +55°C (Should not be Frozen) AMBIENT TEMP. : OPERATING )-20 - 65°C (Should not be Frozen) AMBIENT TEMP. : STORAGE -- 85% RH (Non-Condensing) 25 AMBIENT HUMID. : OPERATING Operation : Single Amplitude 0.35mm, Frequency: 10 - 55Hz, X, Y, Z Axis (3 Axis) / 100m/s2 VIBRATION / SHOCK RESISTANCE Storage : Single Amplitude 0.75mm, Frequency: 10 - 55Hz, X, Y, Z Axis (3 Axis) / 300m/s2 ALTITUDE INSTALLATION ENVIRONMENT PROTECTION 49.8 11 Mounting RESOLUTION RESET 38.3 Panel Cut Dimension 30 Hz COUNT SPEED 3.5 6: 6 Digits Display 8: 8 Digits (GC2 only) Specifications DISPLAY DIGIT Terminal No. Wide Range Voltage Input Type 50 +0.7 +0 3.8 Switch/Open Collector Input Wiring C: Totalizer H: Hourmeter M: Minutemeter S: Secondmeter DISPLAY 49.8 6.5 Wiring G TYPE 6 Digit 8 Digit Models Type 10.2 12.6 LINE SEIKI CO., LTD. 38.3 24.8 Panel mount(50.0 x 25.0mm) 6 / 8 digits LCD display Lithium battery included Battery life 7 years IP54 Front Panel protection level In conformance to CE (EMC), RoHS and UL 863 3.5 1 2 3 4 5 25 +0.7 +0 Customer Service Main Features 4.8 10.6 WARNING Thank you for purchasing this Line Seiki product. Please read this instruction manual carefully before using to ensure correct usage of this product. Please keep this instruction manual for future reference. Please note that misuse of this device may lead to injury to the user or damage to the device. Switch/Open Collector Input Type 54 43.2 Digit Dimension Instruction Manual ATTENTION!!! Precautions when replacing the battery: - Disconnect the wiring before changing the battery. Do not touch areas subject to high voltages, this could result to an electric shock. - Make sure that your body is free from static electricity before changing the battery. - Make sure to follow carefully the procedures described below. Switch/Open Collector Wide Range Voltage 1) Remove the terminal block from the main device. (except wide range voltage input type) 2) Use a flat screwdriver or any appropriate tool to lift the groove in order to disconnect the 'front and back' case hooks. 3) Pull out the back case from the main body. 4) Replace with a new battery making sure that the positive and negative terminals of the battery are positioned correctly. 5) Replace the back case to the main body. Make sure that the case hooks click properly in place. *Please use 3.6V 1/2AA Lithium Battery only for this device. WARNING! 2,000m max. Over-voltage category II , Pollution degree 2 (IEC61010-1) IP54 60g (Battery included) 14-22 AWG Leadwires by Terminal Screw RoHS, UL863, CE EXPLOSIVE! This device uses Lithium battery, it must be disposed properly after use. Do not short the positive and negative terminals, recharge, disassemble, deform by the application of excessive pressure, or dispose the battery to fire as this may seriously damage it or may cause explosion. Do not attempt to disassemble or modify this device. Mount to the front panel when using this device. (Indoor use) Do not use organic solvents such as thinners etc. to clean the front panel. Internal circuit may be destroyed if a voltage outside the rated voltage is applied. This manual was last revised May. 23, 2014. 4GX2001E *Subject to change without prior notice. All Rights Reserved,Copyright © 2014,LINE SEIKI CO.,LTD.
© Copyright 2024