our NEW Equipment Solutions Brochure

Volume 40 • Issue 20
techrentals
Office Locations
From the CEO
TR recently celebrated 40 years of providing you with rental solutions for electronic equipment.
Together, we’ve tackled a diverse range of complex applications and scenarios, working with you to
solve your technical issues utilising TR’s experienced sales and engineering expertise.
We’re continually looking at better ways to cater for your emerging requirements. As a direct result of
listening to your changing needs, we have partnered with industry leading manufacturers to develop TR’s
new Long Term Rental product, an innovative solution that can be tailored to your project’s time frame.
Because of you the industry has grown, as has TR. Today, we connect with over 160,000 people, and so,
we’d like to take this opportunity to thank you for your support and assistance over the past 40 years.
We look forward to serving you and the industry well for another 40.
Dave Gallagher, CEO.
TechRentals Australia
Darwin
Perth
1800 632 652
www.techrentals.com.au
rent@techrentals.com.au
Unit 6, 143 Coonawarra Road
Winnellie
Northern Territory 0820
Ph: 08 8947 2860 | Fax: 08 8947 2901
122 Kewdale Road
Kewdale
Western Australia 6105
Ph: 08 9441 3900 | Fax: 08 9441 3999
Adelaide
Melbourne
Sydney
169 South Road
Ridleyton
South Australia 5008
Ph: 08 8302 8800 | Fax: 08 8302 8899
18 Joseph Street
Blackburn North
Victoria 3130
Ph: 03 9896 3000 | Fax: 03 9896 3099
41 Enterprise Circuit
Prestons
New South Wales 2170
Ph: 02 8777 0800 | Fax: 02 8777 0877
Brisbane
Newcastle
Townsville
72 Donaldson Road
Rocklea
Queensland 4106
Ph: 07 3717 9100 | Fax: 07 3077 8872
Unit 2, 1 Hartley Drive
Thornton
New South Wales 2322
Ph: 02 4966 5910 | Fax: 02 4966 3586
Unit 2, 14 Blackhawk Boulevard
Thuringowa Central
Queensland 4817
Ph: 07 4773 7788 | Fax: 07 4723 5397
TechRentals Malaysia
TR VMS (Calibration, Repair and Sales)
TechRentals New Zealand*
603 5614 1135
www.techrentals.com.my
1300 790 480
www.trvms.com.au
0800 832 475
www.techrentals.co.nz
Selangor D.E
Brisbane
Auckland
29 Jalan Serendah 26/39,
iParc 2, Seksyen 26,
40400 Shah Alam Selangor
Malaysia
Ph: +60 3 5614 1135
Fax: +60 3 5614 4139
72 Donaldson Road
Rocklea
Queensland 4106
Ph: 07 3717 9100
Fax: 07 3717 9148
101A Station Road
Penrose Auckland
New Zealand
Ph: +64 9 589 2030
Fax: +64 9 589 2031
Penang
Sydney
2-1-40, Tingkat Mahsuri 4 (1264),
Terrace-Plus,
11950 Bayan Lepas,
Penang, Malaysia
Ph: +60 4 619 2641
Fax: +60 4 619 2643
41 Enterprise Circuit
Prestons
New South Wales 2170
Ph: 02 8777 0800
Fax: 02 8783 5171
*Distributor of TechRentals Australia
Your trusted partner in technology.
Offering innovative solutions
through our leading brands:
techrentals
hirecom
telecom
Contents
10 Reasons Why You Should Rent
1
Utilise operating expense
Test equipment is expensive often sitting on a shelf collecting
dust – not an effective use of your valuable business capital.
Rental allows you to free up cash for other parts of the business
where it can be used to generate additional profits.
3
4
It is not always clear immediately which make and model will
fulfil your requirements best. Trialling it on casual rental gives
you hands-on experience to guide purchase decisions.
Data & Telecommunications
18
Recover costs more quickly
Electrical Power
24
General Industrial
38
Physical Measurement
52
Eliminate running costs
Cost allocation is simplified
Respond to sudden demands
At peak periods, for unexpected projects, or when essential
equipment breaks down, rental can put the necessary
equipment in your hands ensuring seamless operations.
8
Preserve credit
Renting avoids the potential cost of utilising credit facilities
such as an overdraft or credit cards, which are often used for
equipment purchases.
10
Construction58
Environmental & OHS
64
NEW Long Term Rental Rates 29
Apply new technologies and avoid obsolescence
Rental allows you to update your equipment in line with other
businesses and take advantage of new technologies. It also
avoids the potential cost of owning equipment that can be 
quickly superseded.
9
Electronics8
Conduct product research before purchasing
Rental payments are easy to track and account for in your
business, making it easy to allocate appropriate costs to
departments, clients or specific projects.
7
5
12
The expense of maintaining, calibrating and warehousing your
test and measurement equipment can be high. With rental you
avoid these costs, as well as freeing up storage space within
your premises.
6
Manufacturers Index
Radio Frequency
Generally rental payments are fully tax deductable and the
expense can be recovered far more quickly than the tax
allowances for ongoing asset depreciation.†
5
2
Stretch your budget
Test equipment is often used just some of the time. Rental
allows you to pay for it only when you use it, as well as stretching
your budget by accessing more equipment than you could if you
purchased it outright.
2
General Index
Technical support
When you rent from TechRentals you’ll have the support of an
experienced team of product experts, who’ll help you get the
most from your equipment. And in the unlikely event of equipment
failure we will do our utmost to rectify the issues as soon as possible.
†
TechRentals’ Case Studies 51, 57 & 61
Save time and reduce your real costs.
Find out all about our Configuration and
Download solutions on page 37.
This resource centre provides manuals,
technical information and how-to videos.
Visit www.techrentals.com.au and
select Technical Tips and Videos.
Please ensure you obtain independent professional taxation advice.
1
www.techrentals.com.au
General Index
A
AC See Electrical Power
AC Sources/Inverters/Generators
36
Accelerometer55
Adhesion Tester
52
Air
Flow
58, 59, 66
Quality
58, 59, 66
Air Balancing Hood
58
Air Conditioner Valve Balancing
59
Air Conditioning
Coolant Flow
69
Electronic Manifold
59
Measurement
58
Valve Balancing
59
Air Conditioning & Air Flow
58
Air Quality
Monitoring
58, 64, 65, 66
Particles
65
Pressure & Humidity
58, 66
Air Quality & Heat Stress
66
Airborne Dust & Particle Meter
65
Alcohol (BAC) Breath Tester
65
Alignment
41, 55
Anemometer
58, 59
Antenna and Cable Test
14, 16
Antennas17
Appliance Tester
25
Area Heat Stress
66
B
Balances69
Balances & Scales Below 8kg
69
Balancing Machinery
59
Balometer
58, 59
Barometric Logger
68
Bath
Constant Temperature
42
Battery Management Systems
36
Blast Loggers
56
Body Vibration Measurement
55
Bore Hole Water Quality
67, 68
Borescopes41
Breath Analyser
65
Breath Tester
65
Bridge LCR
9
C
Cable
Fault Locator
24
LAN Test
18, 19
Locator
18, 19, 24, 61
Testers
18, 19
Cable & Fault Locators
61
Cable & Pipe Tracers & Fault Locators
24
Cable Analysers
18
Cable Locators
61
Calibrator
Current
10, 42, 45
Current Loop
10, 42, 44, 45
Dry Block Temperature
42, 45, 46
Electronic
10
Fitting Set
44
Hydraulic
42, 43, 45
Industrial
42, 45
Intrinscially Safe Loop
43
Laboratory
45
Loop
42, 45
Pneumatic Instruments
42, 45
Pressure
42, 43, 44, 45
Process
42, 44, 45
Resistance
10, 42, 44, 45
Temperature
42, 45, 46
Voltage
10, 42, 44, 45
Camera
Endoscope
41
High Speed
41
Pipe Inspection
41, 62
Thermal Imaging
39, 40
Video
41
Carbon Dioxide (CO2)
51, 64, 66
Carbon Monoxide & Nitrogen
Dioxide Monitors
64
2
Carbon Monoxide (CO)
51, 64, 65, 66
Cat 5, 5E, 6
18, 19
Charge Amplifier
55
Chart Recorders
46, 48
Circuit Breaker Analyser System
34, 35
Circuit Breaker Testers
34
Circuit Tracer
24
Clamp-on Sensors
31
Clean Room Monitor
65
Cleaver - Fibre Optic
21
Coating Thickness
52, 54
Combustion Gas Analysis
51
Combustion, Flue & Industrial Gas Analysers 51
Communication Test Sets
16
Compressor Output
Flow
66
Quality
66
Concrete Cover Meter
59
Concrete Hardness Tester
60
Concrete Testing
Adhesion
52
Corrosion
60
Cover Meter
59, 60
Reo Depth
60
Test Hammer
60
Concrete Testing Equipment
59
Concrete Thickness Gauge
59
Confined Space Entry
64, 65
Construction, Building Services & Survey
58
Air Conditioner Valve Balancing
59
Air Conditioning & Air Flow
58
Concrete Testing Equipment
59
Distance Measurement & Surveying
62
Ground Penetrating Radar
61
Pipeline & Cavity Inspection
62
Underground Services Location
61
Utility Leak Detection
61
Counting Scales
69
Crane Scales
54
Current
Clamp
28, 30, 31, 32, 36
DC Source
9
Injection
34, 35
Input Logger
47
Loop
42, 44, 45, 46
Meter
28, 31, 49, 69
Primary Injection
34, 35
Probe
9, 31, 32
Secondary Injection
34
Transformer (CT)
31
Current Clamps Probes & Accessories
31, 32
Current Injectors
34, 35
Current Supply Unit
34
Current Transformer Testing
34
D
Data & Telecommunications
18
DSL/POTS Test Set
20
Ethernet Analysers
19
Ethernet Loopback
19
Ethernet Test Set
19
Etherscope
19
Fibre Optic Launch Cables &
Patch Leads
22
Fibre Optics
18, 22
Fusion Splicers
21
LAN Analysers
19
LAN Cable Testers
18, 19
LAN/WAN Analysers
19
Light Source
21
Light Sources & Power Meters
20, 21
OTDR & Fibre Inspection
22
PDH/SDH Analysers
20
Permanent Link Adaptors
19
WAN Analysers
19
Data Loggers
47, 48
DC High Voltage
9, 31, 32, 33
DC Power Supplies
9, 10
DC Power Supplies & Loads
9, 10
DC Source
9
Decade Resistance Box
10, 45
Demand Analysers
27
Dewpoint66
Digital Storage Oscilloscopes
Distance Measurement
Distance Measurement & Surveying
Dry Block Calibrators
DSL/POTS
DSn/PDH Ethernet Analyser
Ductor
Dust Measurement
E
8, 9
62
62
45
20
20
25, 27
65, 66
E & H Field Strength Meters
10
E1/E3 Tester
19, 20
Earth Leakage
25, 32, 33
Earth Testers
25
Electrical Cable Test
25, 32, 33
Surge Generator
24
TDR
24
Thumper
24
Electrical Installation & Test
Appliance Tester
25
Earth Leakage (RCD)
25, 32, 33
High Voltage Test (Hipot)
32, 33
Insulation Oil Tester
33
Insulation Test
24, 25, 32, 33
Resistance Test
25, 27, 32
Soil/Ground Resistance
25
VLF Testers
33
Electrical Power
24
AC Sources/Inverters/Generators
36
Battery Management System
36
Cable & Pipe Tracers & Fault Locators
24
Circuit Breaker Testers
34
Current Clamps Probes & Accessories
31
Current Injectors
34
Electrical Testers
24
Insulation Testers & Meggers to 20kV
32
Micro-Ohm Meters & Earth Testers
25
Oil, Hipot & VLF Testers above 20kV
33
PAT Testers & RCD Testers
25
Power Analysers & Recorders
27
Power Transformers & Variacs
36
Protection Relay Testing Systems
35
Transformer Testers
34
Electrical Power Generation & Transmission
Current Injection
34
High Voltage Test (Hipot)
33
Power Quality
24, 27, 28, 30, 31
Protection Relay Test
34, 35, 36
Electrical Power Quality
Harmonics
24, 27, 30, 31
Power Factor
24, 27, 30, 31
Power Logger
28
Power Quality Analysers
27, 28, 30
Electrical Power Sources
Battery Management Systems
36
Current Injectors
34
Programmable
36
Electrical Testers
24
Electrical Transducers
24
Electrochemistry67
Electrometers8
Electronic Calibrators
10
Electronic Load
9
Electronics8
DC Power Supplies & Loads
9
Digital Storage Oscilloscopes
8
E & H Field Strength Meters
10
EMC & Power Disturbance Simulators
11
Function Generators
9
Gauss/Tesla Meters
10
Laboratory Calibrators
10
LCR Meters
9
Multimeters & Electrometers
8
Probes & Accessories
9
Spectrum Analysers - Low Frequency
10
TV Test Equipment
10
Electrostatic Charge Measurement
8
Electrostatic Meter
8
Electrochem67
EMC & Power Disturbance Simulators
11
EMC Test Equipment
11
EMC/EMI Test Equipment
11
www.techrentals.com.au
General Index
Endoscopes41
Endoscopes Borescopes Visual Inspection
41
Environment & OHS
64
Air Quality & Heat Stress
66
Airborne Dust & Particle Meters
65
Balances & Scales below 8kg
69
Enviornmental Gas & Vapour Meters
64
Environment Flow Meters
69
Light Meters, UVA/B/C Measurements
68
Moisture & Humidity Meters
66
Noise & Sound Analysers
66
Personal Gas & Vapour Monitors
65
Radiation Monitoring & Protection
67
Water Quality, pH Meters & Weather
Stations
68
Environmental Flow Meters
69
Environmental Gas & Vapour Meters
64
Environmental Noise
66
Environmental Noise Loggers
66, 67
Ethernet Loopback
19
Ethernet Test Set
19
Excavator Cable Locators
61
F
Fault Locators
24, 61
Fault Loop Impdenace Tester
25
Fibre Inspection & Test Kit
22
Fibre Inspection-Capture Probe
22
Fibre Optic Launch Cables & Patch Leads
22
Fibre Optics
22
Cleaver
21
Field Strength Meters
10
Flaw Detector
52
Flow Hood
58
Flow Meters
49, 69
Compressed Air
49
Doppler
49
Gas
49
Liquid
49, 69
Non-Intrusive
49
Open Channel
49, 69
Transit Time
49, 69
Ultrasonic
49, 69
Flow Meters for Liquids & Gases
49
Flue Inspection
41, 62
Force Gauges
54
Formaldehyde Meter
64
Frequency Counters
12
Frequency Response Analysers
34
Function Generators
9
Fusion Splicers
21, 22
G
Gamma Radiation
67
Gas64
Carbon Dioxide (CO2)
51
Carbon Monoxide (CO)
51
Flammable (LEL)
64, 65
Formaldehyde
64
Hydrogen Sulphide (H2S)
64, 65
Methane (CH4)
64
Nitric Oxide (NO)
51
Nitrogen Dioxide (NO2)
51
Oxygen (O2)
51, 64
Ozone (O3)
64
Petroleum Hydrocarbons
64
Refrigerant
64
SF6
64, 65
Sulphur Dioxide (SO2)
64
VOC
64
Gas & Vapour Meters
64
Gas Analysis & Monitoring
51, 64, 65
Gauss/Tesla Meters
10
General Industrial & Process Measurement 38
Combustion, Flue & Industrial Gas
Analysers 51
Data Loggers
47
Dry Block Calibrators
45
Endoscopes Borescopes Visual Inspection 41
Flow Meters for Liquids & Gases
49
High Speed Video Inspection Cameras
41
High Speed Waveform Recorders
46
Industrial Process Calibrators
42
Ground Penetrating Radar
61
H
Hardness Testers
52
Harmonics (Power)
27, 28, 31
Hart Communicators
43
Heat Stress
66
High Frequency Spectrum Analysers 12, 14
High Speed Video Cameras
41
High Speed Video Inspection Cameras
41
High Speed Waveform Recorders
46
High Voltage Insulation DielectricsTest Set
33
Hipot Testers
32, 33
Holiday Detectors
52, 54
Hot Wire Anemometer
58, 59
Humidity
Concrete
59
Indoor Air
66
Logging
47, 48
Natural Gas
66
Thermohygrograph
66
Weather
68
HVAC & IAQ
58, 59, 66
Hydraulic Pressure
42, 43, 52
I
Illuminance Meter
68
Inclinometers54
Indoor Air Quality
66
Industrial Process Calibrators
42, 45
Infrared Cameras
39, 40
Infrared Thermal Imaging Cameras
39
Infrared Thermometers
38
Injection Test Set
35
Instrumentation Amplifier
46
Insulation Diagnostic Analyser
34
Insulation Testers
25, 32
Insulation Testers & Meggers to 20kV
32
Intrinsically Safe
Current Loop Calibrator
42
Gas Monitor
64, 65
Moisture Analyser
66
Photo-Ionisation Detector (PID)
64
IR Thermometers
38
L
LAN
Analysers
19
Cable Certification
18, 19
Cable Testers
18, 19
LAN Analysers/Management
19
LAN Cable Testers
18
LAN/WAN Analysers
19
Landfill Gas Monitor
64
Laser
Distance & Speed
56, 62
Laser Rotational Shaft Alignment 41
LCR Meters
9
Leak Detectors
Electrical
61
Fluid
61
Gas Pipe
61, 64, 65
Mechanical
61
Microwave Oven
67
Refrigerant
64
Water
61
Light Measurement
62, 68
Light Meters, UVA/B/C Measurement
68
Light Source
21
Light Sources & Power Meters
20, 21
Linear Position Transducers
54
Liquid Flow Logger
69
Liquid Flow Meters
49
Load Cells
54
Logger
Accessories
47
Autoclave
47
Data
47, 48
Explosion
56
Flow
49
Humidity
47, 48
Multifunction Switch/Measure Unit
48
Temperature
47, 48
Low Frequency Spectrum Analysers
Luminance Meter
Lux Meter
10
68
68
M
Machinery
Balancing
55
Vibration
55
Magnetic Field Meter
10
Manometer
58, 59
Material Hardness Testers
52
Memory Recorders
46
Methane Monitors
64
Micro-Ohm Meters
25, 27
Micro-Ohm Meters & Earth Testers
25
Microwave Leakage Detectors
67
Microwave Oven Survey Meters
67
Modified Atmosphere
Packaging Test
51, 64
Moisture
65
Wood
60
Moisture & Humidity Meters
66
Moisture Analyser
66
Moisture Balance
69
Modular Power System Mainframe
9
Multimeters8
Multimeters & Electrometers
8
N
Natural Gas
66
Network Analysers
Antenna & Cable Test
14, 16
Cable Test
14
Power
27, 30
RF
14
Network Analysers
14
Network Analyserrs/Antenna & Cable Test
14
Noise & Sound
66
Noise & Sound Analysers
66
Noise Loggers
66, 67
Non-Destructive Testing (NDT)
52, 54
O
Occupational Health & Safety
64
Air Quality
58, 59, 66
Appliance Testing
25
Confined Space Entry
64, 65
Formaldehyde
64
Heat Stress
66
Lighting
68
Noise & Sound
66
Ozone
64
Radiation
11, 67
UV Exposure
68
Vibration
55
Volatile Organic Compound (VOC)
64
Oil Insulation Testers
33
Oil, Hipot & VLF Testers Above 20kV
33
Optical Power Meter
21
Oscilloscopes
Digital Storage
8, 9
Portable
8
OTDR22
OTDR & Fibre Inspection
22
OTDR, FC & Fibre Accessories
22
Oxygen & CO2 Analyser
51, 64, 65
Oxygen (O2)
51, 64, 65
Ozone (O3)
64
P
Pancake Load Cells
54, 55
Particle Counters
65
PAT25
PAT Testers & RCD Testers
25
PDH Analysers
20
PDH/SDH Analysers
20
Permanent Link Adaptors
19
Personal Gas & Vapour Monitors
65
Petrochemical Contamination
64
pH Measurement
67
pH Meters
67
pH reading for Meat Standards
68
pH, mV & Temperature Measurements
68
3
www.techrentals.com.au
General Index
Photo-Ionisation Detector (PID)
64
Physical Measurement
52
Force Gauges
54
Inclinometers
54
Load Cells
54
Material Hardness Testers
52
Non-Destructive Testing
52
Position Transducers
54
Speed Measurement
56
Vibration Analysis
55
Pinhole Detector
52
Pipe Locators
61
Pipeline & Cavity Inspection
62
Pipeline Camera Inspection System
62
Pipeline Inspection
41
Pitot Tube
58
Pobes & Accessories
9
Portable Appliance Testers
25
Position Transducers
54
POTS20
Power
See Electrical Power
Power Analysers
27
Power Analysers & Recorders
27, 28
Power Demand Analysers
27
Power Disturbance
24, 27, 30, 31
Power Loggers
28, 31
Power Meter - RF
16, 17
Power Meters
16
Power Meters & Sensors
16, 17
Power Supplies - DC
9, 10
Power Transformer Testers
34
Power Transformers
36
Pressure
Calibrators
42, 43, 44, 45, 46
Circular Chart Recorder
48
Indicator/Gauge
48
Logging Gauge
48
Pressure Calibrators
44
Pressure Recorders
46
Pressure Transducers
44
Pressure Vacuum Gauge/Recorders
48
Primary & Secondary Test Systems 34, 35
Primary Current Injection Test System
34
Probes
Current
9, 31, 32, 36
High Voltage
9
Line Logic
46
Process Calibrators
44, 45
Profibus
44
Protection Relay Test
34, 35, 36
Protection Relay Testing Systems
35
Pulse Porosity Detector
54
Pumps
42, 43, 45
R
Radar Speed Gun
56
Radiation Monitors
11, 67
Radiation Monitoring & Protection
67
Radiation Monitors
11, 67
Radio Frequency
12
Antennas
17
Communication Test Sets
16
Frequency Counters
12
Network Analysers/Antenna & Cable Test 14
Power Meters - RF
16
RF Accessories
17
RF Amplifiers
17
RF Attenuators
17
RF Signal & Sweep Generators
12
Spectrum Analysers - High Frequency
12
Radiometer68
RCD Test
25, 32
Recorders47
Chart
46, 48
Memory
46
Pressure
46, 48
Refrigerant Leak Detection
64
Relay Test
34, 35, 36
Resistance
Calibration
10, 42, 45
Decade
10, 45
Ground/Soil
25
Micro-Ohm
25, 27
4
Static
RF Accessories
RF Amplifiers
RF Attenuators
RF Power Meters
RF Signal & Sweep Generators
RF Signal Generators
RF Sweep Generators
Rotating Balancing
32
17
17
17
16
12
12
12
55
S
Safety Bolt Inspection System
54
Scales
54, 69
Scopemeter8
SDH Analysers
20
Sensors - RF
16, 17
Shaft Alignment
41, 55
Shaker Table
55
Signal Analysis Software
17
Signal Generators
12
RF
12
Smoke Generating Machine
58
Soil Resistivity
25
Sound
Dose Meter
66
Measurement
66
Signal Analysis
66
Sound Level Meter
55, 66, 67
Vibration
55
Spectrum Analyser
High Frequency
12, 14
Low Frequency
10
RF
10, 12, 14
Spectrum Analysers – Low Frequency
10
Spectrum Analysers – High Frequency
12
Speed Measurement
56
Splicer - Fibre Optic
21, 22
Startup Current
28, 30, 31, 32
Static Discharge Generator
11
STM1 ... STM64
19, 20
Strip Chart Recorders
46
Stroboscope41
Surge Generator
24
Surge Transient Generator
EMC/EMI Test
11
Sweep Generators
12
T
Tachometers41
Tachometers/Stroboscopes41
Tan Delta Measurement
33, 35
TDR24
Telecommunications
18, 20
Access Tester
19
Analysers
19
CDMA
17
Data Tester
20
PDH
20
POTS
20
SDH
19
Temperature
Humidity Loggers
47, 48
IR Thermometers
38
Logging
38
Probes
38
Thermocouples
38
Thermometers
38, 39
Temperature Bath
46
Temperature Meters
38
Temperature Meters/IR Thermometers
38
Test & Tagging
25
Thermal Imaging Cameras
39, 40
Thermocouples38
Thermohygrograph66
Thickness Gauges
52
Time Domain Reflector (TDR)
24
TDR245
TPH Monitor
64
Tracking Generator
12
Transducers
Electrical
24
Humidity
48
Position
54
Pressure
48
Temperature
48
Transformer Insulation Moisture Analyser
34
Transformer Testers
34
Transient Burst
11
Transport
Inclinometers
54
Turbidity
67, 68
TV Test Equipment
10
U
Ultrafine Particle Counters
Ultrasonic Probes
Ultraviolet Test Lamp
Underground Services Location
Utility Leak Detection
UV Exposure
UV Radiation
65
52
52
61
61
68
52
V
Valve Balancing (Air Conditioning)
59
Variacs36
Vehicle Volume & Speed Counter
56
Ventilation Meter
59
Vibration
Accelerometer
55
Analyser
55
Blast Logging
56
Table
55
Transportation
55
Whole Body
55
Vibration Analysis
55
Vibration Calibrator
55
Vibration Logger
56
Video
Endoscopes
41
High Speed
41
Pipeline Inspection
41, 62
Visual Inspection
41, 62
Visual Inspection Equipment
41
Volatile Organic Compounds (VOC)
64
Voltage Calibrator
42, 45
W
WAN Analysers
19
Water
Depth
49, 67, 68, 69
Depth Measurement
67
Flow
49, 69
pH
67, 68
Quality
67, 68
Sampling
67
Water Quality, pH Meters & Electrochem
67
Water/Oil Bath Temperature Calibrator
42
Water/Oil Temperature Bath
46
WBGT66
Weather68
Weather Stations
68
Wet & Dry Block Calibrators
45
Wind Speed & Direction
59, 68
Wind Turbine Lightning Protection Test
Lead Set
27
Winding Transformer Meter
34
Wood & Masonry Testing
Moisture Meter
60
Workplace Safety
See Envivonmental & OHS
X
X-Ray Measurement
67
Manufacturers Index
AARONIA
AAR,HF-6010512
ABACUS
ABB,CB200024
ACTERNA
ACT,MTS800020
ADVANTEST
ADV,U377112
AEROFLEX
IFR,2945B16
AEROQUAL
AER,500L64
AGILENT
(see also Hewlett-Packard
& Keysight)
AGI,DSOX3024A8
AGI,E5071C14
AGI,MSO6104A8
AGI,MSOX3024A8
AGI,N9340A12
AGI,N9344C12
AGI,N9344C-TG12
AGI,N9913A14
www.techrentals.com.au
ANT
ANT,DIRECTIONAL YAGI
ANT,OMNIDIRECTIONAL
17
17
AQUA
AQU,SNAKEEYE362
ARL
ARL,NGARA66
BEAMEX
BEA,MC5
42
BEA,MC5-IS42
BEA,MC6
42
BELL
BEL,419010
BEL,518010
BIRD
BIR,4316
BIR,ELEMENT-HF16
BIR,ELEMENT-LF16
BRUEL & KJAER
BK,2238E-NATA66
BK,4448-IS-3KIT66
AH SYSTEMS
AH,SAS-200/57117
AH,SAS-57117
BW HONEYWELL
BW,BUMP65
BW,GA-NH3-KIT65
BW,GA-SPAK65
BW,MICROCLIP65
AIC
AIC,S-7T-NATA54
CASELLA CEL
CAS,MICROTHERM66
AIRFLOW
AIR,PITOT-3658
CHAUVIN ARNOUX
CHA,PROBE-I9
ALCOLIZER
ALC,WM365
CHROMA
CHR,61501 PAC-PS
ALNOR
ALN,EBT-721-A358
ALN,EBT-73158
COM-POWER CORPORATION
COM,AH-11817
AMETEK
AME,PPCE42
A&D MERCURY
AND,MX5069
ANRITSU
ANR,ANTENNA17
ANR,MA2104A16
ANR,MS2711A12
ANR,MS2712E14
ANR,MS2721A14
ANR,MT9083A SM-MM
22
ANR,MT9083B22
ANR,S331D14
ANR,S331E14
ANR,S331L14
ANR,S332D14
ANR,S332E14
ANR,S332E-CMAP-MOD
16
ANR,S820D16
ANR,WAVEGUIDE-ADAP
16
CRYSTAL ENGINEERING
CRY,NVISION-30-NATA
CRY,XP21-100-NATA
CRY,XP21-300-NATA
CRY,XP2I CAL KIT 1
CRY,XP2I CAL KIT 345
CRY,XP2I CAL KIT 690
CRY,XP2I CAL KIT 7
CRY,XP2I-10K
CRY,XP2I-10K-NATA
CRY,XP2I-1K-NATA
CRY,XP2I-3K
CRY,XP2I-3K-NATA
36
42
48
48
42
42
42
42
48
48
48
48
48
CSCOPE INTERNATIONAL
CSC,CATXDSGA-KIT 61
CSC,CATXDSGV-KIT
24
CSC,CATXDSGV-KIT
61
CONCEPT SMOKE SYSTEMS
CSS,COLT458
DATAKER
DE,CANGATE47
DE,DT8047
DE,DT80047
DE,DT80M47
DE,DT8547
DEFELSKO CORPORATION
DEF,POS-200ADV52
DEF,POS-600052
DEF,POSITEST52
DETEC
DET,W806652
DILLION
DIL,ED2000-5K54
DIL,EDX-20T-NATA54
DIMMER DOT
DIM,D201P36
VAR,D-283-OB36
FIBREOPTIC
FIB,LAUNCH MM 50UM 22
FIB,LAUNCH MM 62.5UM 22
FIB,LAUNCH SM 9UM 22
FIB,MTFS15-100041
FIT
FIT,HP44
FIT,LP44
FITEL
FIT,S123M1221
FIT,S178_S32521
FIXTURELASER
FIX,DIRIGO41
FIX,PAT41
FLEXIM
FLE,G60849
DRANETZ-BMI
DRA-BMI,PG440028
DRA-BMI,PX528
DRA-BMI,TR251031
FLIR SYSTEMS
FLI,E6039
FLI,E60-II39
FLI,T39039
DRUCK
DRU,DPI104-35043
DRU,DPI603-2043
DRU,DPI603-2-NA43
DRU,DPI610-243
DRU,DPI610-2043
DRU,DPI610-2-NATA 43
DRU,DPI610-40043
DRU,DPI610-400-NATA 43
DRU,DPI611-20-NATA 43
DRU,DPI615-20-NATA 43
DRU,DPI620-20-NATA 43
DRU,DPI70558
DRU,DPI705-7BARA 58
DRU,DPI705-IS58
DRU,GENII43
DRU,PV411A43
DRU,UPS III-IS
43
FLUKE
FLU,1523-NATA39
FLU,158732
FLU,1625-KIT25
FLU,1630-EARTH CLAMP 25
FLU,165332
FLU,173528
FLU,199C-SCOPEMETER8
FLU,204224
FLU,289 FLUKEVIEW
8
FLU,28II-EX8
FLU,34528
FLU,37631
FLU,43528
FLU,48167
FLU,52-238
FLU,54-2B-FVF38
FLU,5500A10
FLU,5500A-NATA10
FLU,57639
FLU,700P08-70BAR 44
FLU,700P31-690BAR 44
FLU,700PD3-345 MBAR 44
FLU,700PD6-7BAR44
FLU,718-300G44
FLU,719-100G44
FLU,719-30G44
FLU,72544
FLU,725-NATA44
FLU,72644
FLU,743B44
FLU,74444
FLU,75445
FLU,77345
FLU,789 PROCESSMETER 45
FLU,80K-409
FLU,80TK38
FLU,81055
FLU,87-58
FLU,90I-610S31
FLU,9141-NATA45
FLU,9144-NATA45
FLU,9150-NATA45
FLU,917045
EASY-LASER
EAS,D52541
EA TECHNOLOGIES
EAT,ULTRATEVPLUS 32
ELECOMETER
ELC,331-B59
ELC,331-SH60
EMERSON
EME,37543
EME,47543
ENI
ENI,604L 17
ETM
ETM,990047
EXFO
EXF,FTB-860G19
EXF,PPM352_FIP400 20
EXFO,ETS-1000L19
EXFO,PPM350B20
5
Manufacturers Index
www.techrentals.com.au
FLU,9170-R-NATA45
FLU,990DSL 2/2+
20
FLU,DSX-500018
FLU,DSX-MM18
FLU,DSX-MM EF LEADS 18
FLU,DSX-MMSM18
FLU,DSX-SM18
FLU,DTX180019
FLU,DTX-MFM219
FLU,DTX-OTDR19
FLU,DTX-PLA19
FLU,DTX-SFM19
FLU,DTX-SFM219
FLU,EI-162BN25
FLU,FTK100020
FLU,I5SPQ331
FLU,OPTIFIBER-PRO Q 22
FLU,OPTIFIBER-PRO-MM 22
FLU,Ti12540
FLU,Ti2540
FLU,Ti3240
FLU,Ti32 TELEPHOTO 40
FLU,Ti32_WIDE-ANGLE 40
FLU,VR171028
FUJIKURA
FUJ,FSM60R-CT3021
FUJ,FSM60S-CT3022
FUJ,FSM70S22
FUTEK
FUT,IHH500-20T55
FUT,IHH500-2T54
GENERAL DYAMICS
GD,R8000B16
GE
GE,DYNAMIC52
GE PANAMETRICS
PAN,C-LP-40NM49
PAN,C-PT-10HB49
PAN,GC-RL30249
PAN,GC-RL31949
PAN,OKS49
PAN,PM88066
PAN,PT87849
PAN,PT878E49
PAN,PT878GC-0149
PAN,PT878T49
GENRAD
GR,1433-2010
GR,1433B-NATA10
GR,1433F-NATA10
GEOTECH
GEO,GEM500064
GLOBAL
GLO,FP11169
GLOi AB
GLO,ALISENSOR54
GRANT
GRA,GR150-S5-NATA 6
46
GRIDSENSE
CHK,CK131
CHK,CK531
CHK,CR10031
CHK,CR50031
CHK,PM2027
CHK,PM3027
CHK,PM30PLUS27
CHK,PM3527
CHK,PM40PQA28
CHK,PM4528
HIO,9660CT100A31
HIO,9661 CCT-500A 31
HIO,9661-01 CCT-500A 31
HIO,9669-CCT-1000A 32
HIO,9694CT5A32
HIO,972546
HIO,LCR 3532-50
9
HIO,LR8431-2047
GTI SPINDLE
GTI,IPAD3VAB55
HIGH VOLTAGE INC
HIV,PFT100333
HIV,PFT50333
HAGNER
HAG,EC1-X68
HEWLETT-PACKARD
(see also Agilent & Keysight)
HP,34401A8
HP,35670A10
HP,53181A12
HP,5350B12
HP,6675A9
HP,8449B17
HP,8494/5B17
HP,8494B-8495B17
HP,8495D17
HP,8648D12
HP,8648D-1E512
HP,E4418B-00116
HP,E9300A16
HP,E9300B16
HILTI
HIL,HAT28M54
HIL,PS100060
HIL,PS200 FERROSCAN 60
HIL,PS25060
HIL,PS3860
HIL,TESTER454
HIOKI
HIO,3169-21 CT500AMP 28
HIO,3169-21CLAMPONPT 30
HIO,3169-21CT1000AMP 28
HIO,3196-PQA30
HIO,3196PQA-CT1000A 30
HIO,319830
HIO,328431
HIO,328531
HIO,329031
HIO,340441
HIO,342368
HIO,3455HVIT-5KV 32
HIO,3551BATTERYTEST 36
HIO,3641-2047
HIO,3641-20-KIT47
HIO,8421-0147
HIO,8421-5147
HIO,8422-5148
HIO,884146
HIO,884246
HIO,886046
HIO,893846
HIO,930646
HIO,932046
HIO,9322-KIT48
HIO,933546
HIPOTRONICS
HIP,880PL33
HOLADAY
HOL,HI-360410
HOL,HI-362710
HPI CYPHER
HPI,CYPHER500067
JOF,CTC-650A46
JOF,DPC-1000-NATA 45
KEYSIGHT
KEY,33612A9
KEY,34980A48
KEY,66332A9
KEY,6702A9
KEY,89601B17
KEY,E4416A16
KEY,E4438C12
KEY,N5181B12
KEY,N9030A12
KIKUSUI
KIK,PLZ1003W9
KINGFISHER
KIN,KI28010_2600 KIN,KI7822B-7600A 21
21
KRAUTKRAMER
KRA,DYNAPOCKET52
HUBER & SUHNER
SUH,SUCOFLEX-104PE 17
HV DIAGNOSTICS
HVD,HVA TD60
HVD,HVA30-DC/VLF HVD,HVA60-DC/VLF HVD,HVA90_DC-VLF KYORITSU ELECTRIC
KIK,TOS-510132
33
33
33
33
MADGETECH
MAD,SHOCK10155
HYDROLAB
HYD,MS567
HYDROLOGICAL SERVICES
HYS,OSSB169
IKE
IKE,300PRO62
ILI
ILI,1400ABC68
ION SCIENCE
ION,GASCHECK3000 64
ION,GASCHECKG364
ISCO
ISCO,671267
JACOBS RADIO
JRC,NJJ-95B60
JDSU
JDSU,ANT5-STM16 20
JDSU,ANT5-STM420
JDSU,CSC-ETHERTR-P3 19
JDSU,EDT-13520
JDSU,FIBER_INSPECT 22
JDSU,MTS-4000-FCOMP 22
JDSU,OLA-5520
JDSU,OLP-5521
JDSU,OLS-5521
JDSU,SMARTCLASS 20
JDSU,SMARTCLASS-E1-D 20
JDSU,SMARTCLASS-ETH 19
JOFFRA
JOF,CTC-1200A46
MARCONI
MAR,691016
MAR,691217
MAR,691317
MAR,692317
MAR,697016
MARTINDALE
MAR,PSCI424-58524
MECMESIN
MEC,AFG-1000NALC 54
MEGGER
MEG,CAL30034
MEG,CSU600AT34
MEG,DET2/225
MEG,DET4TC225
MEG,DLRO1025
MEG,DLRO-100LEAD 27
MEG,DLRO10X25
MEG,DLRO20027
MEG,DLRO60027
MEG,DLRO-LEADSET 27
MEG,EZ-THUMP1224
MEG,IDAX30034
MEG,INGVAR34
MEG,MIT1020-10KV DIT 32
MEG,MIT102532
MEG,MIT152532
MEG,MIT52532
MEG,MOM227
MEG,MTO33034
MEG,OTS80PB33
MEG,RCDT33025
MEG,S1-1052 10KV-DIT 32
MEG,S1-552 5KVDIT 32
MEG,TDR2000/2RM 24
MEG,TM176034
MEG,TTR320-4734
Manufacturers Index
www.techrentals.com.au
MEGGER (PROGRAMMA)
PRO,SVERKER76036
PRO,TORKEL-84036
PRO,TXL87036
MEL
MEL,M5-20054
METREL
MET,IT3017INSTALTEST 25
MINOLTA
MIN,CL-20068
MONARCH
MON,PLT200-KIT41
MORITEX
MOR,PALMSCOPE41
MULTIAMP
MUL,MS-234
NARDA
NAR,821767
NAR,NBM-52011
NAR,NBM-55011
NAR,RADMAN67
NOVATECH
NOV,1637-551
NTI AUDIO
NTI,NT-DAS67
NTI,XL2+M221067
OLDHAM
OLD,MX21-SO264
OLYMPUS
OLY,27MG52
OLY,38DL52
OLY,D790-SM52
OLY,EPOCH60052
OLY,IPLEX-LT 3.5
41
OLY,IPLEX-LT 7.5
41
OLY,IPLEX-MXII41
OLY,ISPEEDLT41
PAN,26MG52
OMICRON
OMI,CMA156-6PCA 35
OMI,CMC256-635
OMI,CMC256PLUS35
OMI,CMC35635
OMI,CMC356_61850 35
OMI,CMGPS35
OMI,CPC100PTS34
OMI,CPCB235
OMI,CPCU135
OMI,C-PROBE136
OMI,CPSB135
OMI,CPSTEP35
OMI,CP-TD135
OMI,CTANALYZER34
OMI,DIRANA34
OMI,FRA34
OTT
OTT,KL010-15067
PCWI
PCW,DC3052
PCW,P40-PULSE54
PETROSENSE
PET,PHA-10064
PHANTOM
PHA,5355056
PHENIX TECHNOLOGIES
PHE,BK13033
PHYNIX GMBH & CO
PHY,SURFIX FN
54
POLYSONICS
POL,HYDRA-SX30-2 49
PPM TECHNOLOGIES
PPM,FORM40064
PROCEQ
PRO,2000-ND60
PRO,PROFOSCOPE60
PRO,RESIPOD60
PRO,SIL-UN60
PROFOUND
PRO,VIBRA55
PRO,VIBRA-PLUS55
PROTIMETER
PRO,MMS-PLUS60
PRUFTECHNIK
PRU,AL12.11641
PRU,ROT-PROEX41
PRU,ROT-ULTRA41
PUNDIT
PUN,PL-200E60
RAE SYSTEMS
RAE,MR300064
RAE,PPB300064
RF SYSTEMS LAB
RFS,VJ-ADV41
RH SYSTEMS
RH,973-SF664
RION
RIO,NL-0467
RIO,NL-3267
RIO,NL52EX-NX42RT 67
RIO,VA-1055
RIO,VA-1155
RIO,VA-1255
RISER BOND
RB,1205T-OSP24
RS,NRT17
TR,VIBLOG56
ROTOTHERM
ROT,C10546
ROT,C105-6K46
TSI
TSI,756566
TSI,832458
TSI,837358
TSI,837558
TSI,838059
TSI,8386A59
TSI,852565
TSI,853065
TSI,8530-ENC65
TSI,8530-ENC-S65
TSI,853365
TSI,855466
TSI,871059
TSI,953559
TSI,955559
TSI,9565A59
TSI,AM51065
TSI,TA465A59
ROVER
ROV,HD COMPACT
10
SCHAFFNER
SFN,43811
SFN,MODULA 6100 11
SEWARD
SEW,PAC376025
SEW,PT-30025
SEW,XE3760PKIT+
25
SI PRESSURE INSTRUMENTS
SI,PC6-20-NATA45
SI,PC6-35-NATA45
SI,PC6-700-NATA45
SOFTING
SOF,PROFIBUS-444
SORESEN
SOR,DCS150-20E9
SOR,DCS60-5010
SVANTEK
SVA,SV10055
T&R TEST EQUIPMENT
T&R,CIT35
T&R,DVS3-HP36
TEKTRONIX
TEK,MDO31048
TEK,P60159
TEK,TDS30549
TEK,THS730A9
TEK,TPS20149
TESTO
TES,175-H148
TES,177-T448
TES,33551
TES,350XL51
TES,44558
TES,635-266
TES,635-2-HPD66
TES,645-166
TES,84539
TOUR & ANDERSON
TA,CBI59
TA,SCOPE59
TMS
TMS,9110D-WOB55
RKI INSTRUMENTS
RKI,EAGLE265
TPS
TPS,90FL-T68
TPS,WP-80M68
TPS,WP-8868
ROHDE & SCHWARZ
RS,FSH3-TG14
RS,FSH3-TG-V14
TR
TR,12V-BAT-CIG10
TR,RF-CONN17
UE SYSTEMS
UES,UP300061
UNIDATA
UNI,6526B-21LCD69
USRADAR
USR,SEEK-SPR61
VAISALA
VAI,WXT520-KIT68
VAI,WAA15159
VAN ESSEN
VAN,DI50268
VEEX
VEE,TX-130+20
VEE,TX-130E+20
VEEX,TX-130M+20
VEHICLE COUNTS
VEH,PC250056
VERMASON
VER,222ES8
VIVAX
VIV,VCAM-120M62
VIV,VCAM-60M62
VIV,VLOCPRO61
WIKA
WIK,GA-1565
WOHLER
WOH,VIS34062
WOH,VIS340-PT62
WOH,VIS350-PT62
WYLER
WYL,CL4554
YOKOGAWA
YEW,51001-NATA68
7
Electronics
Multimeters & Electrometers Digital Storage Oscilloscopes
Probes & Accessories
Function Generators
LCR Meters
DC Power Supplies & Loads
Spectrum Analysers - Low Frequency
TV Test Equipment
Electronic Calibrators
Gauss/Tesla Meters
E & H Field Strength Meters
EMC & Power Disturbance Simulators
Multimeters & Electrometers
See also Electrical Testers on page 24
Fluke 28II EX Intrinsically Safe True-RMS Multimeter
FLU,28II-EX (1239) AU
Intrinsically Safe Multimeter is a completely sealed
IP67 rated case. For use inside and outside of
hazardous zones. Measures up to 1000V, 10A AC
and DC with true-RMS for accurate measurement
on nonlinear signals. Frequency measurements
to 200 kHz, resistance, conductance, diode test,
capacitance, and temperature. Results are displayed on the
bright, 4-1/2 digit LCD (20,000 counts).
www.techrentals.com.au
Multimeters & Electrometers cont’d.
Vermason 222541 Electrostatic Meter
VER,222ES (1245) AU
Electrostatic meter for periodic audits of facilities,
monitoring packaging, materials, machines and other
electrostatic generative equipment or processes.
This precision field meter is designed to measure
electrostatic voltage potentials over selected
distances from 1 to 20cm. Range at the standard distance of
2cm is 20kV. Two range 3 digit display in V or kV.
Digital Storage Oscilloscopes
Agilent DSOX3024A Oscilloscope 200MHz 4 Channels
AGI,DSOX3024A (1350) AU
4 channel 200MHz digital storage
oscilloscope. Sampling rate 2 G/s (4 G/s
half-channel interleaved mode). 2Mpts
memory depth, waveform update rate 1
million waveforms/s, sensitivity 1mV/div to
5V/div and 16 digital channels. Built-in 20 MHz function/arbitrary
waveform generator. Pass/fail masks can be automatically
created based on an input reference waveform or on a PC then
imported via USB, also store and remove waveforms via USB.
Agilent MSOX3024A 200MHz Scope 4+16Ch with Logic Analyser
AGI,MSOX3024A (1340) AU
Mixed signal oscilloscope. 4 analogue and
16 digital channels 200MHz bandwidth,
4Gsa/s, 2Mpts memory, 1M/s waveform
update rate. Search and navigate capability.
Integrated time-aligned digital and analog
signal viewing. USB storage, LAN operability.
Agilent MSO6104A 1GHz Digital Oscilloscope with Logic
Fluke 87-5 Industrial True-RMS Multimeter with Thermometer
FLU,87-5 MY
Unique function for accurate voltage and frequency
measurements on adjusatable speed motor drives
and other electrically noisy equipment.True-RMS AC
voltage and current for accurate measurements on
non linear signals. Built in thermometer. Measure up
to 1,000VAC and DC. Measure up to 10A (20A for 30
seconds). 10,000uF capacitance range. Frequency
to 200kHz and % duty cycle. Peak capture to record
transients as fast as 250μs. 4½ digit mode.
AGI,MSO6104A (1320) AU
1GHz 4 + 16 channel mixed signal oscilloscope (MSO). 4Gsa/s.
XGA Colour display updates 100,000 waveforms/s with 256
levels intensity. 4 analogue channels &
16 logic channels. Deep memory. 8 digit
frequency counter function. Triggering
includes video, HDTV, I2C, SPI, LIN, CAN, &
USB. FFT analysis included. LAN, USB, GPIB,
& XGA interfaces standard.
Fluke 199C Scopemeter 200MHz Hand-held
FLU,199C-SCOPEMETER (1360) AU
Fluke 289 True-RMS Logging Multimeter with FlukeView Software
FLU,289 FLUKEVIEW (1236) AU
Complete with a built-in data logger to record
measurements unattended. Internal memory allows
stand-alone logging for up to 180 hours. True-RMS
50,000-count ¼ VGA dot matrix display. 0.025%
Basic DC accuracy. CAT III 1000 V/CAT IV 600 V
safety rated. Supplied with FlukeView software
and download cable.
See also Data Loggers on page 47-48
Agilent/HP 34401A Digital Multimeter
HP,34401A (1242) AU
Precision 6½ digit multimeter. 100nV
sensitivity on DC 120mV range. Max DC
input 1kV. Measures AC voltage, DC &
AC current to 3A, 2 or 4 wire resistance to 120MΩ, period &
frequency. Max reading rate 1,000/s. Maths functions including
limits test. 512 point storage. RS232 & HPIB interfaces.
8
200MHz bandwidth 2 channel colour digital
oscilloscope with DMM feature. 14.4cm colour
display with persistence feature. 2.5GS/s real
time sampling. Input sensitivity 5mV/div to
100V/div. Glitch capture 3ns using pulse width
triggering. Timebase range in scope mode 5ns/
div to 2min/div. Trigger types Auto, Free Run,
Single Shot, Edge, Delay, Video, Video line,
Selectable pulse width and External. Automatic
capture and replay of last 100 screens. Measures electrical
power properties such as VA VAR, etc. Isolated inputs.
Tektronix MDO3104 1GHz Mixed Domain Oscilloscope
TEK,MDO3104 MY
1Ghz, 4 channel oscilloscope with 50MHz
arbitrary function generator, 16 logic
channels and a 3GHz spectrum analyzer.
Sampling rate 5GS/s, 10M record length.
FasAcq feature allows for intensity grading
of rarely occurring events, such as runt pulses, glitches, timing
issues, and more. USB support for transferring or saving results and
settings and PC control using OpenChoice software.
Electronics
www.techrentals.com.au
Digital Storage Oscilloscopes cont’d.
LCR Meters
Tektronix TDS3054B 500MHz 4 Channel DSO
Hioki 3532-50 5MHz LCR Meter
Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV
to 10v/div. Time base 1ns to 10s/div. Trigger functions
include video. Extensive automatic waveform measurements.
Including FFT, TV trigger, advanced analysis (TDS3AAM),
and limit testing (TDS3LIM). Battery operation.
Frequency range 42Hz to 5MHz. 5ms
high speed measurements. Basic
accuracy of ±0.08%. Memory for 30 sets
of measurement conditions, including
comparator values. Includes correlation
correction function, interactive touch panel operation and
enlarged display function. Applications include laboratory use
for evaluation of operating characteristics, production line use or
R&D. Measurement data captured by a personal computer can
be displayed graphically by using standard spreadsheet software.
TEK,TDS3054 MY
Tektronix THS730A 200MHz Battery DSO
TEK,THS730A MY
Dual channel battery portable 200MHz digital
storage oscilloscope with digital multimeter
facilities. Maximum sampling rate 1GS/s.
Maximum input 640V rms, maximum float
600V rms. Waveform processing including watts
calculations. Video trigger. RS232 interface.
HIO,LCR 3532-50 (1290) AU
DC Power Supplies & Loads
Agilent/HP 6675A DC Power Supply
Tektronix TPS2014 100MHz Channel Powerscope
TEK,TPS2014 (1370) AU
Sampling rate 1GS/s. All 4 channels isolated
for floating measurements. Sensitivity 2mV to
5V/div. Measurements for current and voltage
distortion and their spectral content, harmonics,
instantaneous power, power factor and switching
loss. Automatic waveform measurements. FFT, power analysis,
low & high voltage power probes (P5120). Battery operation.
HP,6675A MY
102VDC, 18A, 2000W, auto-parallel up to five units, output can be
connected in series, programmable over-voltage and over-current
protection, over-temperature protection, Discrete Fault Indicator/
Remote Inhibit (DFI/RI), self-test occurs at power-on from an GPIB
command, user definable power-on state and VXI plug & play drives.
Kikusui PLZ1003W Electronic Load
KIK,PLZ1003W (8110) AU
Probes and Accessories
Chauvin Arnoux Current Probe E3N 0 to 100 Amp
CHA,PROBE-I (1440) AU
Current probe for oscilloscopes which uses a Hall effect cell for
the measurement of DC or AC current. Measures currents from
50mA to 100A peak. A thumbwheel can be used to reset zero for
adaption to the measurement environment. The clamp can be
used with any measurement instrument which has a BNC input
and an impedance of 1MΩ, <100pF.
Fluke 80K-40 High Voltage Probe
FLU,80K-40 (1219) AU
1 to 40kVDC or peak AC, 28kVAC rms. Input
resistance 1GΩ, division ratio 1,000:1. Note:
input impedance of DVM must be 10MΩ or
reading will be wrong.
1000 watt electronic load. Voltage
range 1.5 to 120V. Current range 0
to 200A. Provides constant current,
resistance, voltage, and power modes
(CC/CV/CR/CP). A multiple number of setting conditions can be
stored in memory. Sequence function allows setting conditions to
be changed automatically. Applications include characteristic or
lifetime tests of a variety of DC voltage sources such as switching
power supplies, primary and secondary batteries or as burn in loads.
Keysight 66332A Dynamic Measurement DC Source
KEY,66332A MY
Programmable DC Source. 0 to 20V, 0
to 5A. Built-in advanced measurement
system to accurately measure battery
current drains. Battery emulation function.
Tektronix P6015 40kV High Voltage Probe
TEK,P6015 (1450) AU
Bandwidth 75MHz. Input rating: 40kV pulse, 20kVDC plus peak
AC. Derating with frequency applies. Input impedance 100MΩ.
Attenuation x 1000.
Function Generators
See also RF Signal & Sweep Generators on page 12
Keysight 33612A 80MHZ 2 Channel Waveform Generator
Keysight N6702A Low Profile Modular Power
System Mainframe
KEY,N6702A MY
Modular power system mainframe
comes with 2 x N6762A precision
DC power modules(100 watts),
1U high. Each modules capable of 0 to 50V, 0 to 3A.
GPIB, LAN, and USB, interfaces standard, and LXI compliance.
KEY,33612A (1612) AU/MY
Sorensen DCS 150V, 20A DC Power Supply
80MHz, 2 channel waveform generator, sine,
square, pulse, ramp, triangle, Gaussian noise,
PRBS and arbitrary waveforms. Capable of
modulation, sweep, burst, waveform summing and combining.
Maximum output into 50 ohm, 1mVpp to 10Vpp. Up to 120MHz
sine and Gaussian noise at <= 4 Vpp. Memory is 4M Samples deep.
0-150V, 20A, 3KW. Applications range
from manufacturing test and burn-in of
automotive components, avionics electronics, telecommunications
and consumer products to beam steering, process control,
laboratory R&D use. Remote control via LAN or RS232.
SOR,DCS150-20E (8130) AU
9
Electronics
www.techrentals.com.au
DC Power Supplies & Loads cont’d.
Electronic Calibrators cont’d.
Sorensen DCS60-50 60V 50A DC Power Supply
Genrad 1433B 1.1MΩ 6 Decade Resistance
0 to 60V, 0 to 50A. Maximum power on a 240V three phase supply
is 3kW. Maximum power on a one phase 240V supply is 2.5kW.
On One phase 50V@50A or 60V@42A. Remote programming.
Six decades by 1Ω to 1.1MΩ. Accuracy 0.01%. NATA calibrated.
SOR,DCS60-50 (8140) AU
GR,1433B-NATA (1670) AU
Genrad 1433F 111kΩ 7 Decade Resistance Box
GR,1433F-NATA (1680) AU
TR Built 12V Battery Supply with Cigarette Power Connector
TR,12V-BAT-CIG (8160) AU
12V 20AH battery pack with built-in charger. Has cigarette outlet
and banana plug connectors.
Seven decades by 0.01Ω to 111kΩ. Accuracy 0.01% +0.002Ω.
Useful for platinum resistance thermometer calibration.
NATA calibrated.
Genrad 1433-20 11.1111kΩ 6 Decade Resistor
GR,1433-20 MY
Spectrum Analysers - Low Frequency
See also Spectrum Analyser - High Frequency on page 12-13
See also Noise & Sound Analysers on page 66-67
Agilent/HP 35670A 100kHz Spectrum Analyser
HP,35670A (2480) AU
Quad channel 122µHz to 102.4kHz
spectrum analyser. Up to 1600 line
resolution. Displays frequency response,
power spectrum, linear spectrum,
coherence, cross spectrum, power
spectral density, and time. Signal sources: Fixed & swept
sine, arbitrary waveform, random noise, chirp. HPIB plotter
interface. Bandwidth is 102.4, 51.2 and 25.6KHz for single,
dual and quad channel measurements respectively.
TV Test Equipment
See Network Analysers/Antenna and Cable Test on page 14 & 16
Rover HD Compact Combined TV Analyser
Six decades by 0.01Ω per step to
11.1111kΩ. High accuracy 0.01% up to
10MΩ steps. Low temperature coefficient,
5ppm/˚C. Good frequency characteristics, excellent stability
(10ppm/yr, 25ppm/3yrs), low zero resistance (1MΩ per decade).
May be used for RTD stimulation. Rack mount option.
Gauss/Tesla Meters
FW Bell Gauss/Tesla Meter
BEL,4190 (1969) AU
Handheld digital ELF gauss meter. Maintains
accuracy regardless of orientation. Applications
include detecting magnetic field emissions from
overhead AC power lines, video display terminals,
office equipment and household appliances.
Analogue o/p, data logging, auto range 0.1 to
1999 mG, minimum resolution 0.1mG/.01 uT.
FW Bell 5180 Gauss/Tesla Meter
BEL,5180 (1960) AU
For the installation, maintenance and
commissioning of terrestrial, satellite and
cable TV systems DVB T/C/S/S2. The HD
Rover can perform measurements that include
power level, MER, BER, noise margin, SNR,
EVM, network and streams ID’s as well as MPEG4 HD programs
for DVB-T & C. The meter has a USB port for, software upgrades,
channel plan modifications and data logging. Foxtel approved.
Magnetic measuring equipment, portable
gaussmeter. Built-in software eliminates the
need for complex calibration procedures. Key
features include Auto Zero, Min./Max./Peak
Hold, Auto Range and Relative Mode. Allows the
user to select Gauss, Tesla or Ampere/Meter
readings. With Hall effect transverse probe
STD18-0404. Frequency bandwidth DC - 30 kHz,
range from 0 up to 30 kG with a basic accuracy of 1.1% (FS).
Analogue output (±3V FS) and USB interface. Battery operated.
Electronic Calibrators
E & H Field Strength Meters
See also Industrial Process Calibrators on page 42-45
See also Radiation Montioring & Protection on page 67
ROV,HD COMPACT (1748) AU
Fluke 5500A Multi Product Calibrator with NATA Calibration
FLU,5500A-NATA (1660) AU
FLU,5500A MY
Calibrator sources direct voltage
& current, alternating voltage and
current, with multiple waveforms and
harmonics, 2 simultaneous voltage outputs or voltage & current.
Simulates power with phase control, resistance, capacitance,
thermocouples and RTDs. Selectable ranges include the following
outputs Vdc from 0 to 1.02kV, Vac from 1mV to 1.02kV with
output from 10Hz to 500kHz. AC current from 0.01µA to 11A
with output from 10Hz to 10kHz. DC current from 0 to 11A.
Resistance values from short circuit to 330MΩ. Capacitance
values from 330pF to 1,100µF. Temperature t/c B, C, E, J, K, L, N,
R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω, Pt385
200Ω, Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω.
10
Holaday HI-3604 E & H Survey Meter ELF
HOL,HI-3604 (1945) AU
Low frequency field meter. Designed to evaluate electric and
magnetic fields associated with 50Hz power lines. Frequency
range 30 to 2,000Hz. Measures magnetic fields from 0.1
milligauss to 20 gauss. Measures electric fields from 1 volt/meter
to 200 kilovolts/meter. LCD display. 127 reading data memory.
Holaday HI-3627 Magnetic Field Meter
HOL,HI-3627 (1980) AU
Three orthogonal field sensors. Dynamic range
0.2mG~20G. True RMS detection. Frequency
range 5Hz to 2kHz with an in-built 30Hz high
pass filter. Meets requirements of the Swedish
protocol and the IEEE P-1140 protocol.
Electronics
www.techrentals.com.au
E & H Field Strength Meters cont’d.
EMC & Power Disturbance Simulators
Narda NBM-520 ‘E’ Field Strength Meter and Probe EF1891
Schaffner 438 30kV Static Discharge Generator
NAR,NBM-520 (1925) AU
SFN,438 (8375) AU
Field strength meter with EF1891 ‘E’ field probe.
Detects electric fields from 3 MHz to 18 GHz, covering
fields generated by broadcasting, telecoms, radar
and any other transmission sources within this
range. Dynamic range from 0.6V/m to 1,000V/m.
Applications include measuring field strengths to
comply with general safety regulations and actual
radiated power. Includes fibre optic cable with
optical to electrical converts for remote monitoring.
Generates an electrostatic charge in a range
from 2 to 30kV. This instrument is in a ‘gun’
form. Has a removable discharge network
which can be interchanged with other (optional)
impedance networks. Performs test to
IEC61000-4-2 (AKA, IEC 1000-4-2) standards.
Narda NBM-550 ‘E’ Field Strength Meter and Probe EF1891
NAR,NBM-550 (1930) AU
Field strength meter with EF1891 ‘E’ field probe.
Detects electric fields from 3 MHz to 18GHz,
covering fields generated by broadcasting,
telecoms, radar and any other transmission sources
within this range. Dynamic range from 0.6V/m
to 1,000V/m. Includes GPS, data logging, voice
recording annotation and fibre optic cable with
optical to electrical converts for remote monitoring.
Schaffner Modula-6100 Immunity Test System
SFN,MODULA 6100 (8380) AU
Multifunction generator to simulate electromagnetic field interference effects for immunity
testing in conformity with international,
national and in house standards including
the new IEC/EN standards. Generates Interference pulses
such as burst and surge and power quality simulations.
Training with TechRentals
TechRentals works in conjunction with industry leaders like Fluke, Megger, Omicron, Keysight, GE and Anritsu
to provide training opportunities across a wide range of sectors including:
• Electrical Power
• General Industrial Testing
• Physical Measurement
• Data and Telecommunications
• Construction
• Radio Frequency
• Electronics
• Environmental and OH&S
These partnerships allow TechRentals to offer training seminars, instrument specific tutorials, and other content
in various formats to enhance the technical experience and skills of our customers. Of particular value are our
training short courses, the latest of which have included transformer testing, power quality analysis and Australian
fibre and copper standards (with an introduction to encircled flux). These valuable seminars provide insights into
the latest equipment and protocols, with hands on demonstrations on how they benefit industries in the field.
Please email training@techrentals.com.au to be kept informed of upcoming courses.
Visit our wiki for product manuals, how-to
videos, and application notes at https://sites.
google.com/a/techrentals.com.au/wiki/
Check out our YouTube site for over 100 training,
practical demonstration and technical information
videos at http://www.youtube.com/techrentals
11
Radio Frequency
RF Signal & Sweep Generators
Frequency Counters
Spectrum Analysers - High Frequency
Network Analysers/Antenna & Cable Test
Communication Test Sets
Power Meters - RF
RF Amplifiers
RF Attenuators
Antennas
RF Accessories
www.techrentals.com.au
Spectrum Analysers - High Frequency
Aaronia Spectran HF-60105 9.4GHz Handheld
Spectrum Analyser
AAR,HF-60105 MY
Portable Spectrum Analyser, 9KHz to 9.4GHz
comes attached with directional antenna. DANL
-155dBm (1Hz) with preamp DANL -170dBm
(1Hz). RBW 200Hz to 50MHz. Demodulator
for AM/FM/PM/GSM. 1MB memory with
USB interface for trace download. Maximum
power +20dBm. Suitable for cellular walk or drive coverage testing.
Advantest 31.8GHz Portable Spectrum Analyser
ADV,U3771 (2540) AU/MY
RF Signal & Sweep Generators
See also Function Generators on page 9
Agilent/HP 8648D-1E5 4GHz Signal Generator
HP,8648D (2330) AU
HP,8648D-1E5 MY
Signal generator 9kHz to 4GHz with AM/FM/
Phase modulation output range from +10 to
-136dBm with ±1dB accuracy up to 2.5GHz. 0.001Hz resolution.
Complete with option 1E5 high stability timebase (<±0.1ppm/yr).
Portable 9kHz to 31.8GHz spectrum
analyser. 3 way power. Battery, 240V
& DC. RBW 100Hz to 3MHz, sensitivity
-117dBm@34GHz (typ). High-stability
reference. Includes a wide variety
of data analysis functions & zoom
function. With signals applied to both Input 1 and Input
2, two signals such as an IF signal and a carrier can be
measured. Support for USB for printer and memory. Storage
image formats: PNG, BMP, configuration file BIN, XML.
Agilent N9340A 3GHz Spectrum Analyser
with Tracking Generator
AGI,N9340A (2565) AU
Keysight E4438C ESG Vector Signal Generator
KEY,E4438C MY
Vector signal generator, 250kHz to 3GHz.
Built-in function generator. Wideband AM
and FM. Internal baseband generator
(8 Msa), internal bit error rate analyser,
GPS personality, waveform playback and 6GB internal storage.
Keysight N5181B MXG X-Series 6GHz RF
Analog Signal Generator
KEY,N5181B (2328 AU
MXG-X RF Analog Signal Generator, 9 k
to 6 GHz, -144 to +19 dBm. Features
fast switching, low phase noise, pulse,
and narrow pulse, AM, FM, phase modulation and sweep.
Applications include R&D, receiver and component testing.
1000BaseT LAN, LXI, USB 2.0, and GPIB interfaces.
Portable handheld spectrum analyser with a frequency range from
100kHz to 3GHz. Resolution bandwidth 30Hz to 1MHz. Includes
tracking generator. DANL -126dBm (typical). Sweep time 10ms.
USB connectivity allows for PC control and data transfer.
Agilent N9344C 20GHz Spectrum Analyser with Tracking Generator
AGI,N9344C (2538) AU
AGI,N9344C-TG MY
Spectrum analyser 9kHz to 20GHz with
5MHz to 7GHz tracking generator.
-144dBm displayed average noise level
(DANL), <0.95s sweep time for 20GHz full
span. Average continuous power, +30dBm
for 3 minutes maximum. Flexible remote control via USB/LAN.
User memory 64MB, able to store approximately 14,000 traces.
Keysight N9030A PXA Signal Analyser
KEY,N9030A MY
Frequency Counters
See also Electronics on page 8
Real-time spectrum analyser, 3Hz to
26.5G with built-in Pre-Amp (+20dB) and
electronic attenuator(24dB) both up to
3.6GHz. 8 inch XGA display. Run on Windows 7. USB storage port.
Included software: N9051A-Pulse Measurement, N9036A-Analog
Demodulation Measurement and N9064A-VXA Signal Analysis.
Agilent/HP 53181A 3GHz Frequency Counter
HP,53181A (3112) AU/MY
Option 010 high stability timebase included.
HPIB interface. PC based Benchlink meter
software available.
Agilent/HP 5350B 20GHz Frequency Counter
HP,5350B MY
Microwave frequency counter. 10Hz to 20GHz. HPIB interface.
12
Anritsu MS2711A 3GHz Portable Spectrum Analyser
ANR,MS2711A MY
Portable spectrum analyser, 9kHz to 3GHz.
Light weight battery powered spectrum
analyser with LCD. Resolution bandwidth
down to 10kHz. Suitable for cellular
telephone walk or drive tests to determine
coverage and base station positioning.
Can also be used for VHF/UHF signal surveying. N type connector.
Designed and
Manufactured
in U.S.A.
Radio Frequency
www.techrentals.com.au
Spectrum Analysers - High Frequency cont’d.
Network Analysers/Antenna & Cable Test cont’d.
Anritsu MS2712E 4GHz Spectrum Analyser/Tracking Generator
Anritsu S331D 4GHz Colour Sitemaster Antenna
Portable handheld spectrum analyser
9kHz to 4GHz, DANL -162dBm in 1Hz
RBW, RBW 1Hz to 3MHz. Tracking
generator -50dBm to 0dBm in 0.1dB
steps. Applications include, spectrum
monitoring, broadcast proofing, RF and
microwave measurements, Wi-Fi and
wireless network measurements. Store up
2,000 traces and setups on board or on USB flash drive.
One-button envelope creation, Trace Save-on-Event feature.
Antenna and cable test set. Frequency
range 25MHz to 4GHz. Measures return
loss, SWR, cable loss, and distance to
fault. Return loss range 0 to 60dB. SWR
range 1 to 65. Distance to fault range
1,197m. Insertion loss range -120 to
+100dB. Cable loss range (one port) 0 to 30dB. N(f) Type port.
Analysis software discs included containing distance to fault and
Smith chart tools. Complete with calibration standard,
AC/DC adaptor, and 12VDC car cigarette lighter adaptor.
Anritsu MS2721A 7.1 GHz Spectrum Analyser
Anritsu S331E 4GHz Sitemaster Cable & Antenna Tester
100kHz to 7.1GHz. For deploying,
maintaining and troubleshooting
wireless base stations and Wi-Fi
(802.11a, b and g) systems, and
general spectrum analysis. Smart
measurements include channel power,
adjacent channel power ratio, carrier to interference ratio
and field strength. AM/FM/SSB demodulator included and
internal speaker for monitoring. DANL -153 dBm at 1GHz.
Phase noise -100dBc/Hz at 10KHz. Store unlimited traces
and setups. Remote programming via Ethernet port.
Cable and antenna analyser, frequency
range 2MHz to 4GHz. Measures return
loss, VSWR, cable loss, and Distance
To Fault. Suitable for legacy networks in
addition to the new 3G and 4G networks
being installed. Applications include cable & antenna installation
and maintenance for wireless service providers, contractors,
military, aerospace, defence, and public safety applications.
ANR,MS2712E (2560) AU
ANR,MS2721A (2550) AU
ANR,S331D MY
ANR,S331E (2180) AU/MY
Anritsu S331L 4GHz Sitemaster Cable & Antenna Analyser
Rohde & Schwarz FSH3 3GHz Spectrum Analyser/Tracking
Generator/Vector Measurement
ANR,S331L (2178) AU
Handheld portable battery operated spectrum
analyser 100kHz to 3GHz. Resolution
bandwidth 1kHz to 1MHz. Less than -105dBm
noise level (-114dBm typical). Suitable for
RF surveying applications. Includes vector
transmission and tracking generator options.
Cable and antenna analyser, frequency
range 2Mhz to 4GHz. Built in power
meter 50MHz to 4GHz, -33dBm to
+20dBm. Measures return loss, VSWR,
cable loss, and Distance To Fault.
Suitable for legacy networks in addition
to the new 3G and 4G networks being
installed. Applications include cable & antenna installation
and maintenance for wireless service providers, contractors,
military, aerospace, defence, and public safety applications.
Network Analysers/Antenna & Cable Test
Anritsu S332D Colour Sitemaster Antenna Tester
RS,FSH3-TG-V (2575) AU
RS,FSH3-TG MY
ANR,S332D MY
Keysight E5071C-260 ENA Series Network Analyser
KEY,E5071C (2744) AU/MY
2 port 9 kHz to 6.5 GHz network analyser
with integral S-parameter test set.
Dynamic range >123dB. High stability
timebase. Applications for manufacturing
and R&D engineers evaluating RF
components and circuits for frequencies up to 6.5 GHz.
Calibration kit 85032F included. LAN/USB/GPIB connectivity.
Antenna and cable test set including
spectrum analyser. Frequency range
25 to 4,000MHz. RBW 100Hz to 1MHz.
Measures return loss, SWR, cable
loss, and distance to fault. N(f) Type
port. Analysis software containing DTF
and Smith chart tools included. Complete with calibration
standard, AC/DC adaptor, and 12VDC car adaptor.
Anritsu S332E Sitemaster including Spectrum Analyser
Agilent N9913A FieldFox 4GHz Cable & Antenna Analyser
AGI,N9913A (2145) AU
Cable and antenna analyser, frequency range
30kHz to 4GHz. Measures return loss, one-port
cable loss, distance to fault, line sweeping, and
VSWR. Applications include cable & antenna
installation and maintenance for wireless service
providers, contractors, military, aerospace,
defence, and public safety applications.
QuickCal and remote control capabilities included.
14
ANR,S332E (2175) AU
Antenna and cable analyser 2MHz to
4GHz and spectrum analyser 100KHz to
4GHz. DANL -152dBm. Measures return
loss, VSWR, cable loss, and distance to
fault. N(f) Type port. Analysis software
containing DTF and Smith chart tools
included. Complete with calibration standard, AC/DC adaptor,
and 12VDC car adaptor. Cable & antenna installation and
maintenance for wireless service providers, contractors, military,
aerospace and defence, and public safety applications.
Rental vs Purchase
Why rental is more cost effective than ownership
When weighing up whether to purchase or rent your two way radio communications, it is
clear that the benefits of rental far outweigh the cost of ownership. Not only does rental
save you money, but it’s the smarter business option, providing you with greater flexibility
and control. At the end of your rental period, simply return the equipment and upgrade to
a newer version, it’s that easy!
3 Rental costs can be 100% tax deductible#
3 Ongoing service and technical support
3 Immediate replacement of faulty equipment 3 No capex account process required
3 Battery replacement program
3 Avoid obsolescence
Please see the chart below which illustrates the benefits of rental over
ownership for 6 x Motorola DP4801-Ex two way radios with a multi-unit charger
Motorola DP4801-Ex with a multi-unit charger
$20,422
Purchase
hirecom
$4,292
Rental
$ 0
5,000
10,000
15,000
20,000
For more info call us
on 1800 222 327
25,000
Figures displayed represent costs at the end of the first year.
All rental rates quoted are based on a 3 year period.
Purchase Price ($15,660) and Cost of Money (8%)
Depreciation and Cost of Money (8%)
Service & Repair (15%) and Battery Replacement*
Net Rental (after tax deduction of $1,840 per year)#
*Battery replacement calculated on average battery life of 18 months (This cost has been spread over 3 years).
Rental vs Ownership for 6 x Motorola DP4801-Ex two way radios with a multi-unit charger
$
30,000
25,000
Total
Cost of Ownership
vs
Cost of Rental
$29,653
This graph illustrates the money saved when choosing
rental over ownership based on a 3 year period.
20,000
15,000
$12,878
$9,882
5,000
0
$4,292
Year 1
$9,789
$4,292
Year 2
$4,292
Year 3
Ownership
Cost
Rental
Cost
#Please ensure you obtain independent professional taxation advice. Prices shown are accurate as of date of publication and are subject to change. Percentages illustrated are based on purchase price.
Terms and conditions of rental apply as shown on www.techrentals.com.au. Prices exclude GST. Figures shown have been rounded to the nearest dollar.
15/10/2014
BR0367
$9,982
10,000
Radio Frequency
www.techrentals.com.au
Network Analysers/Antenna & Cable Test cont’d.
Power Meters - RF cont’d.
Anritsu S332E Sitemaster Including Spectrum Analyser
and Opt 431,31,509
Agilent/HP E9300A Power Sensor 1µW to 100mW, 10MHz to 18GHz
ANR,S332E-CMAP-MOD (2165) AU
Power sensor for HP EPM series power meters. E-series average
power sensor. 10MHz to 8GHz, 1µW to 100mW (-60dBm to +20dBm).
Antenna and cable analyser 2MHz to 4GHz
and spectrum analyser 100KHz to 4GHz.
DANL -152dBm. Options included, indoor
outdoor Coverage Mapping, GPS Receiver and
AM/FM/PM Analyser. Measures return loss,
VSWR, cable loss, and distance to fault. Analysis software containing
DTF and Smith chart tools included. Cable, antenna, installation
and maintenance spectrum analysis, coverage mapping and AM/
FM/PM demod for wireless service providers, contractors, military,
aerospace and defence, and public safety applications.
HP,E9300A (2125) AU
Agilent/HP E9300B Power Sensor 1µW to 25W, 10MHz to 8GHz
HP,E9300B (2135) AU
Power sensor for HP EPM series power meters.
E-series average power sensor. 10MHz to
18GHz, 1µW to 25W (-30dBm to 44dBm).
Keysight E4416A EPM P-Series Power Meter
Anritsu S820D Microwave Sitemaster 25MHz to 20GHz
KEY,E4416A MY
Microwave antenna and cable test set.
Portable single port analyser, providing return
loss (SWR) insertion loss and distance to
fault measurements in the frequency range
of 25MHz~20GHz. Unit comes standard
with RS232 interface, Smith chart and software management
tools, AC/DC and automotive adaptor. A comprehensive range of
precision waveguide components and adaptors are available.
Power meter, for peak, average, peak-to-average
ratio and time-gated measurements. 100µW to
25W (-70dBm to 44dBm), 9 kHz to 110GHz (power
sensor dependent ), 4 digit display - watts, dBm, dB
(rel). Analyser Software for complete pulse and statistical analysis.
8 pre-defined wireless configurations (GSM, EDGE, NADC, iDEN,
Bluetooth™, IS-95 CDMA, W-CDMA and cdma2000). Comes with
E9322A Peak & Average Power Sensor (50MHz to 6GHz, 1.5MHz
bandwidth, -45dBm to +20dBm at Normal Mode).
ANR,S820D (2150) AU/MY
Anritsu Sitemaster Waveguide Components
ANR,WAVEGUIDE-ADAP (2190) AU/MY
Calibration components and wave guide to co-ax adaptors for
Anritsu S820x Sitemaster. Set includes 1/8 and 3/8 shorts,
termination, and waveguide to co-ax adaptor.
Communication Test Sets
General Dynamics R8000B Communications Analyser
GD,R8000B (2380) AU
Portable test instrument designed to monitor
and service radio communications equipment
up to 1GHz. It generates and receives signals,
measures modulation and frequency, and
performs a variety of tests on AM, FM, PM and
optional digital standards P25, DMR, NXDN
and TETRA radio transceivers. Features include, enhanced spectrum
analyser, oscilloscope, and tracking generator. Power handling
capabilities without external attenuator is 50W for 5 min, up to a time
limited 150W (see equipment specifications to avoid damage).
Aeroflex IFR 2945B Communications Service Monitor
Anritsu MA24104A Inline Power Sensor 0.6 to 4GHz, 2mW to 150W
ANR,MA24104A (2115) AU
A dual path architecture that enables true RMS
measurements over the entire frequency and
dynamic range allowing users to measure CW,
multi-tone and digitally modulated signals such
as GSM/EDGE, CDMA/EV-DO,WCDMA/HSDPA,
WiMAX, and TD-SCDMA. Can be connected
directly to a laptop or Site Master with option 19.
Bird 43 Power Meter
BIR,43 MY
RF thruline power meter. Requires Bird element of specified
frequency and power. Measures forward and reflected power
by reversing the element.
Bird RF Element
BIR,ELEMENT-LF MY
BIR,ELEMENT-HF MY
RF elements for Bird watt meters. Available in various power and
frequency ranges.
IFR,2945B (2390) AU
Communications Service Monitor is
ideally suited to the testing of two
way radios and trunking repeaters
allowing verification of performance,
and rapid diagnosis of faults. Includes
a combination of test instruments such
as a full performance spectrum analyser, oscilloscope and
tracking generator. Frequency range 400kHz to 1.05GHz.
Power Meters - RF
Agilent/HP E4418B E Series Power Meter
HP,E4418B-001 (2120) AU
100µW to 25W (-70dBm to 44dBm), 9 kHz
to 110 GHz (power sensor dependent),
4 digit display - watts, dBm, dB (rel).
Battery or mains powered. Power sensor
required, select and specify when ordering.
16
Marconi 6970 Digital Power Meter
MAR,6970 MY
NiCd battery operated with digital display. Complete with AC
adaptor. Requires sensor. Sensors available for 10MHz to
26.5GHz frequency range.
Marconi 6910 Power Sensor
MAR,6910 MY
Frequency range 10MHz to 20GHz. Power range -30dBm to
20dBm (1μW to 100mW). Max RF i/p 25dBm (300mW) CW
42dBm (15W) peak for 2μs. Sensing element semiconductor
thermocouple. VSWR 1.25: 10MHz to 30MHz, 1.1: 30MHz
to 2GHz, 1.18: 2 to 16GHz, 1.28: 16 to 18GHz, 1.4: typical
18 to 20GHz. Linearity factor provided with sensor.
Accuracy ±0.5% at 25˚C between 10 & 20dBm. Improves by
a factor of 10 for each lower range. Calibration factor provided
with sensor. Accuracy uncertainty provided with sensor.
Resolution 0.01%. RF connector precision N-type (M) 50Ω.
Radio Frequency
www.techrentals.com.au
Power Meters - RF cont’d.
RF Attenuators cont’d.
Marconi 6912 Power Sensor
Agilent/HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB
MAR,6912 MY
Frequency range 30kHz to 4.2GHz. Power range 30dBm (1μW)
to 20dBm (100mW).
Marconi 6913 Power Sensor
HP,8494/5B MY
DC to 18GHz. 0 to 11dB in 1dB steps. 11 to 81dB in 10dB steps.
Comprises a connected set of types 8494B & 8495B.
Type N(f) connectors.
MAR,6913 MY
Agilent/HP 8495D 70dB 26.5GHz Step Attenuator
Frequency range 10MHz to 26.5GHz. Power range 30dBm (1μW) to
20dBm (100mW). Max 25dBm (300mW) CW, 42dBm (15W) peak
for 2μs. Sensing element semiconductor thermocouple. VSWR
1.40: 10MHz to 50MHz, 1.15: 50MHz to 100MHz, 1.10: 100MHz
to 2GHz, 1.15: 2 to 12.4GHz, 1.20: 12.4 to 18GHz, 1.25: 18 to
26.5GHz. Calibration factor provided at 1GHz intervals (500MHz
intervals above 20GHz) with each sensor. Accuracy uncertainty
provided with each sensor. Resolution 0.01%. Linearity factor
accuracy ±0.5% at 100mW, decreasing by 0.005% per 1mW.
HP,8495D MY
Marconi 6923 RF Power Sensor
MAR,6923 MY
High sensitivity diode sensor. Frequency range 10MHz to
26.5GHz. Power range -65dBm (0.3nW) to -20dBm(10μW), max
26dBm (400mW) CW, +30dBm (1W) peak for 2μs. Sensing
element Shottky barrier diode. VSWR 1.4 10 to 40MHz, 1.15
40 to 100MHz, 1.12 0.1MHz, 1.17 2 to 8GHz, 1.30 8 to 18GHz,
1.50 typical 18 to 26.5GHz. Calibration factor provided at
1GHz intervals with each sensor. Accuracy uncertainty provided
with each sensor. Resolution 0.01%. Linearity factor provided
with each sensor. Accuracy ±1% between -30 to -20dBm. RF
connector type N (M) precision 50Ω.
Rohde & Schwarz NRT Power Reflection Meter
RS,NRT (2140) AU
Measures directional power forward and reverse under
operational conditions. NRT-Z44 sensor included, range 3 mW to
120 W, 200 MHz to 4 GHz. Measurement method is compatible
with all common analog and in particular digital modulation
standards. GSM/EDGE, 3GPP (W-/TD-CDMA), CDMA (IS-95),
CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB,
DVB-T and many more.
Frequency range DC to 26.5GHz. 70dB step attenuator in 10dB
steps. Max continuous power 1W. 3.5mm connectors.
Antennas
AH Systems SAS-200/571 Antenna
AH,SAS-200/571 (1840) AU
AH,SAS-571 MY
Double ridge guide horn antenna. Frequency range 700MHz to
18GHz. Continuous power 300W. Impedance 50Ω 200V/m max
radiated field. Type N(f) connector.
Anritsu Dipole Antenna Kit
ANR,ANTENNA (1834) AU
MP534A dipole antenna 25 to 520MHz and MP651A 470
to 1700MHz.
Directional Yagi Antenna
ANT,DIRECTIONAL YAGI (1829) AU
Various directional Yagi antennas. Frequency rangers from 824 M
(UHF) to 2.17 GHz (UHF).
Omnidirectional Antenna
ANT,OMNIDIRECTIONAL (1826) AU
Various omnidirectional antenna types such as telescopic whip, folded
dipole and monopole. Frequency rangers from 70MHz to 5.4GHz
COM Power Double Ridged Horn Antenna 1 to 18GHz
COM,AH-118 MY
RF Amplifiers
Frequency range 1 to 18GHz, VSWR 2.0:1, Polarization: Linear,
Output Impedance: 50Ω, connector types Antenna output: N (f).
ENI 604L 4W Wideband 1GHz RF Amplifier
RF Accessories
Linear wideband RF power amplifier. 4W output at an input of
0.13mW from 0.5 to 1GHz. Saturated output 7W 0dBm input.
Extended performance gives saturated output to a max of 16W
at 10MHz and 12W at 100MHz typically.
KEY,89601B MY
ENI,604L (2803) AU
Agilent/HP HP8449B Preamplifier 1GHz to 26.5GHz
HP,8449B MY
High-gain (+30dB gain), low-noise preamplifier. Frequency range
of 1 to 26.5GHz. Increases sensitivity of any microwave spectrum
analyser for detection and analysis of very low-level signals.
Improved sensitivity can reduce measurement time.
RF Attenuators
Keysight 89601B Vector Signal Analysis Software
A comprehensive set of software tools for demodulation and vector
signal analysis. Measure and analyse signals in the time, frequency
and modulation domains. Analyse data from over 40 supported
hardware instruments, or use in simulation tools to verify design.
Included license: 200-Basic Vector Signal Analysis, 300-Hardware
Connectivity, AYA-Vector Modulation Analysis and TEDS-Modulation
Analysis. For you with N9030A PXA Signal Analyser.
Huber & Suhner Sucoflex 104PE 26.5GHz RF Cable
SUH,SUCOFLEX-104PE MY
Fexible high performance microwave cable with frequency range up
to 26.5GHz. Length 1.0 meter and comes with 3.5mm connectors.
Agilent/HP 8494B/8495B Attenuator Set 81dB, 1 & 10dB steps 18GHz
HP,8494B-8495B MY
Coaxial step attenuator set. DC to 18GHz. 0-11dB in 1dB steps
and 10-70dB in 10dB steps. Type N(f) connectors.
Comprises a connected set of types 8494B and 8495B with
11716A rigid interconnect kit.
RF Connector Kit N, BNC, TNC, SMA, APC7
TR,RF-CONN (2816) AU
RF connection adaptors. Comprises couplers with
interchangeable connectors; DIN 7/16, N Type, BNC, SMA,
TNC, APC-7 and UHF
17
Data & Telecommunications
LAN Cable Testers
LAN/WAN Analysers
PDH/SDH Analysers
DSL/POTS Test Set
Light Sources & Power Meters
Fusion Splicers
OTDR & Fibre Inspection
Fibre Optic Launch Cables & Patch Leads
LAN Cable Testers
Fluke DSX-5000 Cable Analyser 1GHz Class FA
FLU,DSX-5000 (3278) AU/MY
1 1GHZ cable analyser copper test solution
enables testing and certification of twisted pair
cabling for up to 10 GigE deployments and
will certify shielded and unshielded structured
cabling systems from Cat 3, to 7A and Class C,
to FA at Level V accuracy. 9 second Cat 6 autotest. Built in Alien
Crosstalk testing capability. PLA004 (Cat 6A/Class EA), CHA004 (Cat
6A/Class EA) adapters and LinkWare PC reporting software included.
Cabling
Certification –
Versiv™
Faster systems acceptance
for all copper and fiber
certification jobs.
Fluke CertiFiber Pro MM Optical Loss Test Set
FLU,DSX-MM (3269) AU/MY
Multimode (CFP-MM-ADD) optical loss test set
modules for the Versiv DSX-5000. Provides Tier 1
certification at 850 and 1300 nm in 3 seconds.
A set reference wizard ensures correct reference
setting. Encircled Flux compliant as required
by ANSI/TIA and ISO/IEC. Measures fibre optic
attenuation, length, and propagation delay.
Includes built in VFL and Linkware software.
DSX-5000
CableAnalyzer™
CertiFiber®
Pro
OptiFiber®
Pro OTDR
OneTouch™ AT
Network Assistant
Kit of Encircled Flux MM Test Reference Leads for the DSX-MM
FLU,DSX-MM EF LEADS (3385) AU/MY
Kit consists of Encircled Flux (EF) compliant test reference leads
for the following fibre networks: SC, ST 62.5um (OM1 & 2), SC
50µm (OM3 & 4) Suitable for the Fluke CertiFiber Pro Optical
Loss Test Set, (CFP-100-M).
Fluke CertiFiber Pro MM-SM Optical Loss Test Set
FLU,DSX-MMSM (3263) AU
Multi and singlemode (CFP-Q-ADD) optical loss test
set modules for the Versiv DSX-5000. Provides Tier
1 certification at 850, 1300, 1310 and 1550 nm
in 3 seconds (for 2 wavelengths). A set reference
wizard ensures correct reference setting. Encircled
Flux compliant as required by ANSI/TIA and ISO/
IEC. Measures fibre optic attenuation, length, and
propagation delay. Includes built in VFL and Linkware software.
Fluke CertiFiber Pro SM Optical Loss Test Set
FLU,DSX-SM (3264) AU/MY
Multi and singlemode (CFP-Q-ADD) optical
loss test set modules for the Versiv DSX5000. Provides Tier 1 certification at 850,
1300, 1310 and 1550 nm in 3 seconds
(for 2 wavelengths). A set reference wizard ensures correct
reference setting. Encircled Flux compliant as required by ANSI/
TIA and ISO/IEC. Measures fibre optic attenuation, length, and
propagation delay. Includes built in VFL and Linkware software.
18
Email: sales.au@flukenetworks.com
Phone: 02 88503333
or call Jeff Hardman: 0419 183 284
Data & Telecommunications
www.techrentals.com.au
LAN Cable Testers cont’d.
LAN/WAN Analysers
Fluke DTX1800 Cable Analyser 900MHz Cat 7
EXFO ETS-1000L 10/100/1000 Ethernet Loopback
Category 7 cable certification tester up to
900MHz. Tests to Category 3, 4, 5, 5E, 6, 6a
and 7. Cable analyser for use with shielded and
unshielded twisted pair Cat 6 Autotest time of
12 seconds. Linkware PC software, and USB
cable included. Internal memory stores results.
Optional multimode & single mode OTDR module.
Ethernet/Gigabit ethernet loopback unit ETS1000L is intended for performing loopback at
the physical, data link, network and transport
layers of the OSI model. It allows carrying
out loopback control via OAM protocol and
remote control via TELNET protocol.
FLU,DTX1800 (3260) AU/MY
EXFO,ETS-1000L MY
EXFO FTB-860G NetBlazer 10G Ethernet Tester
Fluke DTX-MFM2 Multimode Fibre Adaptor for DTX Cable Analyser
FLU,DTX-MFM2 (3270) AU/MY
DTX1200/1800 multimode fibre
interface. Tests fibre installations in
local area networks. Fits in the slot on
the back of DTX cable analyser (standard
copper cable adaptors can be connected
but not used simultaneously). Provides
fibre testing and certification. Bi-directional testing at
850nm and 1300nm at the same time. Measures optical
power loss, length, and propagation delay for multimode
fibres. Pass/fail results based on common fibre
standards. Includes in built visual fault locator. (VFL).
EXF,FTB-860G (3223) AU
Performs 10 Gbps RFC 2544
measurements and EtherSAM (ITU-T
Y.156sam), for turnkey deployment,
validation, and troubleshooting of access
and metro ethernet services. IPv6
testing capabilities BERT, RFC, traffic
gen and through mode. NetBlazer offers
GUI navigation, dedicated quick-action
buttons, and clear notifications for
accurate interpretation of test results.
JDSU SmartClass 10M-1G Ethernet Tester
Fluke DTX Compact OTDR SM-MM
FLU,DTX-OTDR (3280) AU
Full featured multimode & single mode OTDR
module that snaps onto a DTX Cable Analyser.
Shoots and analyses traces on single mode 9nm
and multimode 62.5 & 50nm fibre.
Fluke DTX Permanent Link Adaptor
FLU,DTX-PLA (3295) AU
JDSU,CSC-ETHTR-P3 (3249) AU
SmartClass Ethernet for comprehensive
installation, turn up and maintenance
of Ethernet IP services up to 1 Gbit.
Performs Bidirectional RFC 2544,
Asymmetric RFC and multiple streams
testing. Applications include performance
assessment of Carrier Ethernet services,
activation and maintenance of metro
Ethernet networks, deployment of active
Ethernet (point-to-point) access services,
traffic generation and QoS verification.
Fluke PLA001 Permanent Link Adaptor.
Fluke DTX Fibre for DTX Cable Analyser
FLU,DTX-SFM MY
DTX1200/1800 singlemode fibre interface. Tests fibre
installations in local area networks. Fits in the slot on the back
of DTX cable analyser (standard copper cable adaptors can
be connected but not used simultaneously). Provides fibre
testing and certification. Bi-directional testing at 1310nm
& 1550nm at the same time. Measures optical power loss,
length, and propagation delay for singlemode fibres. Pass/
fail results based on common fibre standards. SC optical
connectors. Includes in built visual fault locator (VFL).
JDSU SmartClassEthernet 10M-1G Ethernet Tester
JDSU,SMARTCLASS-ETH (3220) AU
Two SmartClass Ethernet(s) provided for
comprehensive installation, turn up and
maintenance of Ethernet IP services up to
1 Gbit. Performs Bidirectional RFC 2544,
Asymmetric RFC and multiple streams
testing. Applications include performance
assessment of Carrier Ethernet services,
activation and maintenance of metro
Ethernet networks, deployment of active
Ethernet (point-to-point) access services,
traffic generation and QoS verification.
Fluke DTX-SFM2 Single Mode Fibre Adaptor for DTX Cable Analyser
FLU,DTX-SFM2 (3265) AU/MY
DTX1200/1800 single mode fibre
interface. Use for testing fibre installations
in local area networks. Fits in the slot
on the back of DTX cable analyser
(standard copper cable adaptors can be
connected but not used simultaneously).
Provides fibre testing and certification. Bi-directional testing
at 1310nm and 1550nm at the same time. Measures optical
power loss, length, and propagation delay for single mode
fibres. Pass/fail results based on common fibre standards.
SC optical connectors. Includes in built visual fault locator. (VFL)
Learning to operate unfamiliar equipment
costs you time and can lead to errors.
Save time and reduce your real costs.
Find out all about our Configuration
and Download solution on page 37
19
Data & Telecommunications
PDH/SDH Analysers
JDSU ANT 5 SDH/PDH Access Tester
www.techrentals.com.au
PDH/SDH Analysers cont’d.
VeEx VePal TX130M+ DSn/PDH/Ethernet Analyser
JDSU,ANT5-STM4 (3445) AU/MY
VEEX,TX-130M+ MY
Field tester for the installation, commissioning
and fault finding of fibre and copper SDH/
PDH networks. Electrical interfaces for
PDH/SDH: E1, E3, DS3, E4, STM-0e/1e;
Optical interfaces for SDH/SONET: STM-1/
OC-3, STM-4/OC-12. BERT, round trip delay
measurement, error performance analysis: G.821, G.826, G.828,
G.829, M.2100,M.2101 and ANSI. Autoconfig functionality for
automatic traffic detection, line rate, structure and mapping.
Offline Viewer SW provides result analysis and report generation.
Full-featured Mobile Backhaul test solution
supporting legacy PDH/DSn, Carrier Ethernet
technologies, and Synchronized Packet networks.
The unit is capable of emulating both Master and
Slave clocks according to ITU-T G.8261 SyncE and
IEEE 1588v2 standards. At the same time able to
provide E1 and 1G Ethernet Testing according to
RFC2544 standards. It has options of Pulse Mask,
E1 Wander and MTIE&TDEV.
VeEx VePal TX130+ E1/Datacom Tester
JDSU ANT 5 SDH/PDH Access Tester
JDSU,ANT5-STM16 (3446) AU/MY
SField tester for the installation, commissioning and fault finding
of fibre and copper SDH/PDH networks from 1.5Mb/s to 2.5
Gb/s. Optical testing at dual wave lengths at STM-1, STM-4, and
STM-16. Electrical testing at DS1/E1/E3/DS3/E4 and STM-1
interfaces. Full analysis of concatenated mappings. ATM analysis
for service verification of ATM and 3G/UMTS networks.
VEEX,TX-130+ MY
Handheld field tester for installation and commissioning of E1
and Datacom services. It is a small and compact unit.
DSL/POTS Test Set
Line and DSL Test Set
FLU,990DSL 2/2+ (3470) AU
JDSU EDT-135 E1 and Data Tester
JDSU,EDT-135 (3450) AU/MY
Field service tester for commissioning,
maintenance and troubleshooting of E1
PCM2Mbps and V.11/RS-442, V.24/RS-232,
V.35,V.36/RS-449, EIA-530 data circuits operating
at 50bps to 2Mbps. Provides framed & unframed
monitoring, end-to-end testing, drop & insert,
channel associated signalling; error & alarm analysis, S bit, NFAS &
NMFAS monitoring & generation. Round trip delay measurement,
G.821, G.826 & M.2100 quality of service measurements.
Signal level measurement & primary multiplexer testing.
Acterna MTS 8000/T-BERD Transport Module
JDSU,MTS8000 MY
Multirate interface for PDH-DS1/DS3/E1/E3/E4,STS-1 OC3/12/48/48, STM-1e/1/4/16 and interface for OC-192 STM-64 with
the ability to monitor down to the STS-1 level inside of any supported
optical rate. Used for verifying and qualifying the performance of
SDH and Gigabit ethernet, telecommunications networks. Electrical
and optical interfaces at rates 1310/1550nm). Also supports the
NewGen (ethernet over Sonet/SDH) and able to perform RFC2544.
Ethernet IP testing with 10/100/100Mbps electrical RJ-45 Interfaces.
Supports VLAN, Q-in-Q,VPLS,MPLS Tunnelling application. Comes with
touch screen GUI operation. Measures optical power and frequency.
Floppy drive installed.
JDSU SmartClass E1/Datacom Tester
JDSU,SMARTCLASS-E1-D (3440) AU
JDSU,SMARTCLASS MY
Handheld field tester for the installation and
commissioning of E1 and Datacom services.
Applications include (not limited to), G.703 2Mb/s testing, 2 M (Bulk), n x 64kb/s BERT, audio
monitoring (VF drop & insert),ABCD/Sa monitoring,
alarms (defects) and errors (anomalies) insertion,
round-trip delay, DTE / DTE emulation and monitor
mode. Interfaces with X.21, V.24 (RS-232), V.35,
V.36 (RS-449), and EIA-530.
CopperPro broad range Plain Old Telephone
Services (POTS) troubleshooting, fault location and
line qualification capabilities. Includes Wideband/
TDR option which adds high frequency transmission
testing and qualification functions for services like
ADSL 2/2+, VDSL, HDSL, HDSL2 & 4, ISDN, T1, E1
and DDS. TDR feature adds precise fault location
and analysis. Includes TN2100 remote terminator.
Light Sources & Power Meters
EXFO PPM-350B-EG PON Power Meter
EXFO,PPM350B MY
OptimiSed for FTTx E & GPON. PPM350B has 10 user-definable
threshold sets, each set consisting of three wavelengths (1310,
1490 and 1550 nm) having their own pass/warning/fail analysis
features. Simultaneous measurement and display of all PON
signals voice, data and video.
EXFO PON/FTTx Power Meter & Inspection Probe
EXF,PPM352_FIP400 (3370) AU
Kit includes PPM-352B-EG-ER optimized for FTTx E
& GPON & FIP-400 inspection probe with handheld
display. PPM352 has 10 user-definable threshold
sets, as well as pass/warning/fail analysis features.
Simultaneous measurement and display of all PON
signals voice, data and video.
Fluke FTK1000 Multimode Fibre Optic Light Source & Meter
FLU,FTK1000 (3365) AU/MY
Light source is multimode 850nm and 1300nm.
Power meter has 850/1300nm multimode and
1310/1550nm single mode. Manage results
and print reports via Power meter memory, PC
and supplied software.
JDSU/Acterna OLA-55 Single Mode Optical Attenuator
VeEx VePal TX130E+ DSn/PDH/Ethernet Analyser
JDSU,OLA-55 MY
Full-featured Mobile test solution supporting legacy PDH/
DSn and Carrier Ethernet technologies. Provides E1 and
1G Ethernet Testing according to RFC2544 standards.
Adjustable wavelength from 1260 to 1650nm
(1nm increments). Calibrated wavelengths
1310nm, 1550nm & 1625nm. Maximum permitted
level =23dBm. Optical Interface: FC-PC.
VEEX,TX-130E+ MY
20
www.techrentals.com.au
Light Sources & Power Meters cont’d.
Little-Known Facts
about the Leaning
Tower of Pisa
Although designed to
be perfectly vertical, the
56-meter tower tilts at an
angle of roughly 10 degrees.
The tower started to lean
during its construction
phase (1173 to 1379).
Today, the tilt is more than
five meters off vertical center.
So, what caused the tower
to lean? It was built on soft,
marshy land.
This imperfection made
the Tower of Pisa a piece
of art—and an example of
engineering-gone-wrong.
JDSU OLP-55 Optical Power Meter
JDSU,OLP-55 MY
Optical Power Meter BN 2277/01 Power & Loss Measurement
for installation, maintenance and repair of fiber optics networks.
Display Range: -70 to +20dBm, calibrated wavelengths: 850,
1310, 1550 & 1650nm. Optical connection: FC.
JDSU OLSP-55 Optical Laser Source
JDSU,OLS-55 MY
Operates on dual wavelength of 1310nm and 1550nm.
Output power is from -7 to 0 dBm. Optical Interface: FC-PC.
Kingfisher KI-28010 Single Mode APC Light Source
and KI-7600 Power Meter
KIN,KI28010-2600 (3361) AU
Singlemode light source KI-28010 and power meter
KI-2600. Compatible with APC and PC singlemode
networks. Wavelengths 1310, 1550 and 1625nm.
Memory with text, timestamp and USB dump, realtime PC reporting software. Autotest provides fast,
easy and automatic multi wavelength loss testing.
Kingfisher KI7822B- KI7600A Single Mode Light
Source & Power Meter
KIN,KI7822B-7600A (3362) AU
Light source (KI7822B) and power meter (KI7600A)
optical fibre test set for single mode applications
(1310nm and 1550nm). Power meter has large
user memory and flexible real-time PC reporting
software. Autotest provides automatic multi
wavelength loss testing. The meter displays
mW, µW, nW, dB, dBm to 0.01dB resolution, with no range
changing delays. Power meter can be used for multiple single
and multimode wavelengths. Laser output power 0dBm.
Fusion Splicers
BUILD ON STRONG FOUNDATIONS
WHEN DEPLOYING FTTA, DAS OR
SMALL CELLS
Stronger Wireless Also
Means Stronger Wireline.
To Ensure Reliable
Fiber Networks,
Get the Test Expert.
EXFO.com/FTTA
Fitel S123M12 Ribbon Fusion Splicer
FIT,S123M12 (3312) AU
Hand-held ribbon fusion splicer can splice from
1 to 12-core ribbon fibre (12-core ribbon fibre
holders supplied). Protection sleeve shrink time
is 35 seconds, while splicing requires only 15
seconds for 8 or 12 ribbon fibre allowing up
to 160 splicing cycles (splicing/heating) using
the 2 battery packs installed in the main body.
Includes, S325 cleaver and thermal jacket stripper.
Fitel S178 Fusion Splicer and S325 Cleaver
FIT,S178_S325 (3314) AU
S178 hand-held, core-alignment fusion splicer
and S325 cleaver. Splicer provides typical losses
of 0.02dB and 0.01dB on single and multimode
fibre respectively. 7 second splice time, built in
heater and tension test. Can be operated from
battery or AC source. Precision fibre cleaver can
be used with single & multimode fibres and features a built in
sharps collection bin that automatically stores fibre off-cuts.
Fujikura FSM60R Ribbon Fusion Splicer, Cleaver, Stripper
FUJ,FSM60R-CT30 (3310) AU
Ribbon fibre fusion splicer, will splice from 1 to
12-core ribbon fibre (12-core and 900µm single
fibre holders supplied). Splice time 20 sec, sleeve
shrink time 40 sec, typically. Detachable work
table and arc-free calibration system. Includes
CT-30 fibre cleaver and thermal jacket stripper..
21
Data & Telecommunications
Fusion Splicers cont’d.
Fujikura FSM60S Splicer & CT30 Cleaver
www.techrentals.com.au
OTDR & Fibre Inspection cont’d.
Fluke Optifiber Pro Multimode OTDR
FUJ,FSM60S-CT30 (3320) AU/MY
FLU,OPTIFIBER-PRO-MM (3343) AU
Typical splice losses of 0.02dB and 0.01dB
on single and multimode fibre respectively.
Features splice protection heater, detachable
work table and arc-free calibration system.
Multimode OTDR, wavelengths 850 and 1300nm.
Designed for testing, troubleshooting and
certifying multimode 50 and 62.5um fibre optic
networks. Smartphone user interface, shortest
event and attenuation deadzones, LinkWare
download and reporting software included.
Fujikura FSM70S Core Alignment Fusion Splicer
FUJ,FSM70S (3318) AU/MY
Single fibre core alignment fusion splicer and
CT30A cleaver. Typical splice losses of 0.02dB
and 0.01dB on single and multimode fibre
respectively. Automated tension test, wind
and heater cover, 7 second splice time and
14 second heat time.
OTDR & Fibre Inspection
Fluke Optifiber Pro Quad OTDR
FLU,OPTIFIBER-PRO Q (3344) AU/MY
Multi and singlemode OTDR, wavelengths 850,
1300, 1310 and 1550nm, dynamic range 28,
30, 32 and 30 dB respectively. Designed for
testing, troubleshooting and certifying multi
and singlemode 62.5, 50 and 9um fibre optic
networks. Smartphone user interface, shortest
event and attenuation deadzones, LinkWare
download and reporting software included.
See also LAN Cable Testers on page 18-19
Anritsu MT9083B Access Master Singlemode OTDR
JDSU Fibre Inspection-Capture Probe
ANR,MT9083B SM (3336) AU
JDSU,FibeR_INSPECT (3340) AU
Complete testing of PON-based FTTx
networks featuring up to 1x64 splits or
single fibre runs. 1310, 1550 and 1625
wavelengths, dynamic range 40, 39 and
38 respectively. Intelligent analysis software
identifies problem splices, connectors and
even macrobends. 400x Video Inspection Probe (VIP) and 8
tips included. Active fibre verification. Store up to 1,000 traces
in internal memory and up to 30,000 via your USB device.
Handheld display, dual magnification (200/400x)
probe and USB adaptor for fibre end-face image
analysis and capture. Includes software and
various probe tips.
Anritsu MT9083A Access Master SM and MM OTDR
ANR,MT9083A SM-MM (3337) AU
850/1300 nm (29/28dB) and 1310/1550
(39/37.5dB). Singlemode port is SC/APC.
Intelligent analysis software identifies
problem splices, connectors and even
macrobends. Full 1×64 PON support.
Store up to 1,000 traces internally (much
more using USB), drop and drag results to PC.
JDSU MTS-4000 OTDR with E4136FCOMP-MA
JDSU MTS-4000-FCOMP (3334) AU
Maintain metro and PON-based FTTx
networks. 1310, 1550 and 1625nm
wavelengths at 42, 40 and 40 dB dynamic
range (respectively), includes power meter,
VFL, NBN auto test sequences and fibre inspection probe.
Performs insertion loss (IL), optical return loss (ORL) and
OTDR from one optical port. Applications include bidirectional
testing, trouble shooting and acceptance testing.
Fibre Optic Launch Cables & Patch Leads
Launch Fibre Multimode 50µm 100m
FIB,LAUNCH MM 50UM (3380) AU
Fibre optic consumables are available for sale.
Please ask for delivery when placing your rental order.
100 metres of 50µm fibre terminated with SC
connectors. A launch fibre enables an OTDR
to measure the loss of the first connector and
adapts a 62.5µm OTDR to a 50µm network.
Launch Fibre Multimode 62.5µm 300m
FIB,LAUNCH MM 62.5UM (3382) AU
SC to SC multimode 62.5µm launch fibre.
Launch Fibre Single Mode 9µm
FIB,LAUNCH SM 9UM (3378) AU
Single mode 9µm SC launch fibre.
22
Calibration and Repair
Australia’s leading calibration laboratory. Established 1989.
•Defence • Aviation • Biomedical • Communications • Electrical
•Construction • Mechanical • Mining • Other
Have all your calibration and repair needs covered, including
major manufacturers:
3 Fluke
3 Tektronix
3 Megger
3 Barfield
3 Stahlwille
3 Agilent
3 Anritsu
3 GE Measurement & Control
3 Plus many more…
Authorised Service Agent for Barfield Aviation, Megger Electrical,
and Stahlwille Torque products
Prestons
41 Enterprise Cct
Prestons NSW 2170
Rocklea
72 Donaldsons Road
Rocklea QLD 4160
1300 790 480
www.trvms.com.au
VM0141
Your calibration can be provided with a NATA endorsed report to
ISO/IEC 17025 requirements or a non-NATA endorsed calibration report.
Electrical Power
www.techrentals.com.au
Cable & Pipe Tracers & Fault Locators
Electrical Testers
PAT Testers & RCD Testers
Micro-Ohm Meters & Earth Testers
Power Analysers, Loggers & Recorders
Current Clamps Probes & Accessories
Insulation Testers & Meggers to 20kV
Oil, Hipot & VLF Testers above 20kV
Transformer Testers
Circuit Breaker Testers
Current Injectors
Protection Relay Testing Systems
AC Sources/Inverters/Generators
Power Transformers & Variacs
Battery Management Systems
Cable & Pipe Tracers and Fault Locators cont’d.
Megger EZ-Thump 12kV Thumper & TDR Power
Cable Fault Locator
MEG,EZ-THUMP12 (3610) AU
Designed as a portable cable fault finder. It operates
off either AC supply or internal batteries. The kit
includes the Megger pinpointer to locate faults when
used in thump mode. Internal battery provide 30mins
of thumping with a 3hr recharge time. Generates a
500J 0~12kV @12mA pulse for thumping.
Megger TDR20002RM Dual Channel TDR Cable Fault Locator
MEG,TDR2000/2RM (3605) AU
Time Domain Reflectometer cable fault locator. User selectable
ranges from 0 to 50m up to 20km, minimum resolution 0.1m.
Dual cursor measurement. Internal memory for 15 traces.
Megger “Tracemaster” software supplied. RS232 interface for PC
communications. High resolution LCD display. Battery powered.
Dust and shower proof to IP54.
Riser Bond 1205T-OSP Metallic TDR Cable Fault Locator
RB,1205T-OSP MY
Cable & Pipe Tracers and Fault Locators
See also Ground Penetrating Radar on page 61
See also Underground Services Location on page 61
CScope CATXDSGV-KIT Cable and Pipe Locator
CSC,CATXDSGV-KIT (3730) AU/MY
Industry standard locator used to determine
the exact location of buried pipes and cables.
Functions include: Power mode for detecting live
imbalanced cables to a depth of 3m. Radio mode
for detecting re-radiated radio signals to a depth
of 2m. Generator mode for detecting conductors
carrying the signal generated by the C.Scope
signal generator.
Fluke Cable Locator
FLU,2042 (3602) AU
Ideal for tracing cables in walls and
underground, locating fuses/breakers on final
circuits as well as locating interruptions and
short-circuits in cables and electrical floor
heating systems. Can be used for tracing
metallic water and heating pipes. Supplied
as a kit comprising a transmitter and receiver
in a carry case. Voltage measurement range 12 to 400 volts.
Frequency range 0 to 60Hz. Transmitter output signal 125kHz.
Transmitter voltage 0 to 400V ac/dc. Depth location 0 to
2.5m. Receiver voltage detection range 0 to 0.4m. The receiver
incorporates a torch for working in dimly lit locations.
Dual input metallic time domain reflectometer cable fault locator
for coaxial cables. Maximum Range: 63,700ft (19,400meters)
at .990 VOP. Distance Accuracy: ±0.1ft (0.03m) plus ±.01% of
reading. Can store, recall and download waveform, via RS232
cable. (Viewable with Software.)
Electrical Testers
See also Current Clamps Probes & Accessories on page 31-32
ABB CB-2000 Portable Capacitance Meter
ABB,CB2000 (3500) AU
Portable (2.4kg) capacitance meter (0-1000µF)
which allows individual capacitors in a capacitor
bank to be measured without disconnection. Battery
powered with an ac adapter. Approximately 8 hours
operating time between charges. Supplied software
and drivers allow measured values to be exchanged to and from a
PC via supplied USB cable. Data stored as tab delimited text files.
Martindale Phase Sequence & Continuity Indicator
100 to 600V, 50/60Hz
MAR,PSCI424-585 (3502) AU
Check the presence and sequence of the phases on
3ph circuits. Provides a visual indication of loss of
phase or incorrect sequence. Supplied in 2 forms.
Probe style; the connection to the tester is via 3
insulated cables to 3 fused test probes, 1 with an
insulated crocodile clip. Plug style; a 16A, 4 pin (3ph
& earth, BS4343) plug is fitted to the tester. Use as a
socket tester prior to plugging in 3ph equipment.
Watch equipment how-to videos using QR codes
To complement our highly qualified technical support team, we are creating a range of informative
how-to videos for equipment in our rental inventory. If you see a QR code on your equipment,
simply scan the code with a QR mobile phone app to watch the relevant video. As we are
constantly adding videos and QR codes to our fleet, be sure to check our YouTube channel for all
the available videos, and do not hesitate to contact our team if you have any questions.
24
Electrical Power
PAT Testers & RCD Testers
www.techrentals.com.au
Micro-Ohm Meters & Earth Testers
Megger RCDT330 Residual Current Device Tester
Fluke 1625 KIT GEO Earth Ground Tester
MEG,RCDT330 (2618) AU
FLU,1625-KIT (2650) AU
Tests standard, DC, selection and programmable RCDs. Ramp
testing. Auto (remote) testing. Auto sequence test feature. 3ph safe.
Enables testing on 110V centre tapped supplies. Performs 1/2I,
1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA, 300mA,
500mA & 1,000mA on general and selective (time delayed) RCDs.
Weatherproof to IP54. USB interface for test results download.
Metrel IT3017- Installation Tester for Testing to AS/NZS3000
MET,IT3017INSTALTEST (2610) AU
Multifunction installation tester with measurement
functions and Pass/Fail limits set to AS/
NZS3000 Wiring Rules. Capable of storing test
results for printing compliance test reports.
In-built Australian measurements and Pass/
Fail limits, and guarantees accountability and traceability with
storing of test results. Simply conduct the test, press the Memory
button to save the result and assign the result to a location, then
download results to PC software and print-out compliance test
reports with actual test results. Earth Continuity & Resistance,
Insulation Resistance, Polarity, Correct Circuit Connections,
Fault Loop Impedance and RCD Testing. “Auto-Sequence Test”
mode further speeds up compliance testing and reporting.
Measure total earthing resistance (RA) with 3 or 4-pole Fall of
potential method, selective earth resistance measurement and
4-pole soil resistivity testing (0.001Ω to 19.99kΩ). Stakeless ground
loop measurements (0.001Ω to 199.9Ω). Includes automatic
frequency control to minimise interference effects. Battery powered.
Fluke 1630 Earth Ground Clamp
FLU,1630-EARTH CLAMP (2651) AU/MY
Earth ground loop testing and continuity testing
without breaking the circuit. Ground loop resistance
range 0.025Ω to 1.5KΩ. Ground leakage current
measurement range 0.2mA to 1000mA. Current
measurement range 0.2A to 30A. Logs and stores
measurements for on screen recall. LCD display.
Battery powered.
Fluke Clamp for Ground Loop Resistance around Power Pylons
FLU,EI-162BN (2652) AU
Split core transformer designed to work with the
Fluke 1623 and Fluke 1625 earth ground testers
to make selective earth ground loop resistance
measurements on power pylons. Inner diameter
of the clamp is 310mm.
Seaward PAC 3760 Appliance Checker
SEW,PAC3760 (2605) AU
Performs the following tests in conformance to
AS/NZS 3760:2000; earth bond, insulation &
polarity tests, leakage current tests for Class I &
Class II appliances and leads (leakage current
testing of appliances, which requires power to
“switch” them on, is the method required by AS/
NZS3760:2003). Simple pass/fail indication. Unique 3 button
operation. Class I, class II and leakage current. Automatic test
sequence senses an IEC or or extension lead then performs a
polarity test. Detects that the appliance under test is switched “On”.
Earth bond test is set at 10A and is capable of fusing a poor earth.
Megger High Accuracy Configurable Diagnostic Earth Tester
MEG,DET2/2 (2653) AU
Provides a wide resistance range from 0.01Ω
to 19.99kΩ for testing larger or more complex
grounding systems and for difficult testing
environments, with ±0.5% accuracy and 0.001Ω
resolution. Microprocessor control and advanced filtering simplify
testing in environments with high levels of interference.
Megger DET4TC2 Digital Earth Tester With Kit
MEG,DET4TC2 MY
Comprises the Seaward PrimeTest 300 appliance and
RCD tester, ProTag Optima test tag printer and the
BCS-Blue bar code scanner. Battery powered, weighs
around 2kg. Carries out all of the tests required under
AS/NZS3760 for appliances and leads, and 30mA RCD
tests. Operates as a handheld data logging device by
recording any type of test, inspection or risk assessment
with user defined inspection routines and an in-built library of
measurement and engineering units for recording actual results.
Measurement range of 0.010Ω to 200kΩ,
ground noise voltage measurement from 1V
to 100V and ground current from 1mA to 20A.
Accurate results can be obtained in electrically
noisy environments since it is capable of
rejecting noise voltages of 40V peak to peak and
the user can select different test frequencies to
minimise the effect of interference. Powered from 8 AA batteries.
Supplied with ICLAMP. Auguments the traditional fall-of potential
measurement method with ART (Attached Rod Technique) which
allows electrode testing without disconnection and also leakage
current measurements down to 1mA. The VCLAMP enables true
stakeless measurements to be made in situations where driving
stakes is not practical.
Seaward Supernova XE3760+ PAT System with Printer and Scanner
Megger DLRO10 Micro-Ohm Meter
Seaward ProTag OPTIMA-300 Testing and Tagging System
SEW,PT-300 (2603) AU
SEW,XE3760PKIT+ MY
Includes results label/tag printer and barcode
scanner. Performs all AS/NZS3760: 2001/2003
compliant tests, including class 1 & class 2
leakage current 5mA/1mA, an earth conductor
bond test up to 25A at 3V (approx. 100W) and
250VDC MOV insulation resistance tests. Stores 5,000 tests
in internal memory by appliance ID, including test type, detailed
results, test time & date, next test due date, site & location.
Calibrated resolution better than the required 5% of FS across all
ranges as specified by the Standard. Full QWERTY keyboard, and
bar code reader for input. Durable plastic adhesive test label/
tags printed to attach to appliances and leads includes user ID
(logo optional on request) and test barcode ID, saves transcription.
Compatible with Seaward PATGuard plus software package.
MEG,DLRO10 (2661) AU
Self contained fully automatic micro-ohm meter,
selecting the most suitable test current up to 10Adc.
Range 0.1µΩ to 2kΩ, resolution 0.1µΩ. LED display.
Rechargeable battery.
Megger DLRO10X Digital Low Resistance Ohm Meter 10A/0.1µΩ-2KΩ
MEG,DLRO10X (2633) AU/MY
Self contained fully automatic (with manual option)
micro-ohm meter, selecting the most suitable test
current up to 10Adc. Range 0.1µΩ to 2kΩ, resolution
0.1µΩ. Internal memory for 700 tests. Download
software supplied. RS232 communications to PC.
LCD display. Rechargeable battery.
25
Offices Sydney – Melbourne – Brisbane – Perth
26
26
Electrical Power
www.techrentals.com.au
Micro-Ohm Meters & Earth Testers cont’d.
Power Analysers, Loggers & Recorders cont’d.
Megger DLRO200 200A Micro-Ohm Meter
CHK Gridsense Powermonic PM30 Power Quality Analyser
MEG,DLRO200 (2664) AU
CHK,PM30 (8705) AU
Test current range 10A to 200Adc. Measurement
range 0.1mΩ to 1Ω, resolution 0.1mΩ.
Current cables 2 x 5m. Internal memory for
300tests. Download software supplied. RS232
communications to PC. LCD display.
Weatherproof IP65 field unit. Channels 3 voltage,
63V to 440V (isolated), 4 current 0 to 3kA (3ph
& neutral) RMS. Supplied with 3 x 1kA clampon CTs (cable capacity 50mm). Clamp-on CTs of
3kA, 1kA for large conductors and 500A & 100A
for neutral conductor current measurement are
available. Memory 4Mb. In-built 2 line LCD display.
Records V, A, pF, f(Hz), kVA, kVAr, kW, harmonics,
(THD and individual to 48th). Total energy, tariffs, max demands,
transient and sub-cycle disturbances. Software provides graphs and
summaries to PC. Download files while logging via RS232 interface.
PC using Win 95, 98, NT4, 2000, XP, O/S, is required with the CHK
POWERview software to configure this unit before operating.
Megger DLRO600 Digital Micro-Ohm Meter - High current
MEG,DLRO600 (2665) AU/MY
Test current range 10A to 600Adc. Measurement
range 0.1µΩ to 1Ω, resolution 0.1µΩ.
Current cables 2x5m. Internal memory for 300
tests. Download software.
Megger DLRO Wind Turbine Lightning Protection Test Lead Set
CHK GridSense PowerMonic PM30 Plus Power Quality Analyser
MEG,DLRO-100LEAD (2662) AU
CHK,PM30PLUS (8706) AU/MY
For Megger DLRO 10 series digital micro-ohm
meters. Specially designed for measuring resistance
of lightning protection circuit between wind turbine
blade tip and ground. Kelvin clip and hook ends on
100m cable reel. 5m DH2 lead with duplex hand
spikes and hook end.
Weatherproof IP65 field unit. Channels: 3 Voltage,
63V to 440V (isolated). 3 current 0 to 3,000A
(3ph) rms. Supplied with 3 flexible 3,000A
clamp-on CTs (flexible CT length 600mm and
190mmØ). In addition, clamp-on CTs of 3,000A,
1,000A for large conductors and 500A and 100A
for neutral conductor current measurement are
available. Memory: 4Mb. Inbuilt two line LCD
display. Records: V, A, pF, f(Hz), kVA, kVAr, kW, harmonics, (THD
and individual to 48th). Total energy, tariffs, maximum demands,
transient and sub-cycle disturbances. Included software provides
graphs and summaries to PC. Download files while logging RS232 interface. A PC using Windows 95, 98, NT4, WIN2000 or XP
O/S, is required with the CHK POWERview software to configure
this unit before operating.
Megger DLRO Lead Set Current & Voltage Leads
MEG,DLRO-LEADSET (2666) AU
For Megger DLRO digital micro-ohm meters. Potential spike lead
set x2 and current clip lead set x2. Leads are used to separate
the C & P connections. This avoids the erroneously high readings
taken due to a high resistance contact. Current clip lead set 2m
(242041-7) and potential spike set 2m (242021-7).
Megger MOM2 Micro-Ohm Meter
MEG,MOM2 (2638) AU/MY
Lightweight (1kg), handheld micro-ohm meter.
Up to 220A test current, autoranging from
999µΩ to 1000mΩ FS. Rechargable batteries
provide 2200 measurements for Imin = 50A, or
800 for Imin = 100A. Memory for 190 recorded
measurements, downloadable via Bluetooth
with provided software. Kelvin probes included.
Power Analysers, Loggers & Recorders
See also Current Clamps Probes & Accessories on page 31-32
CHK GridSense PowerMonic PM35 Power Quality Analyser
CHK,PM35 MY
Power logger and disturbance analyser.
Weatherproof IP65 field unit. 3 Voltage (55VAC to
520VAC) and 4 current (0 to 3,000A) channels.
Supplied with 4 flexible 3,000A clamp-on CTs
(flexible CT length 600mm and 190mmØ).
Memory: 15Mb. Inbuilt two line LCD display.
Records: V, A, pF, f(Hz), kVA, kVAr, kW, harmonics,
(THD and individual to 48th). Flicker (Pst & Plt),
Total energy, tariffs, maximum demands, transient
and sub-cycle disturbances. Included software provides graphs
and summaries to PC. Downloads files while logging. High speed
USB interface. A PC using Windows 95, 98, NT4, WIN2000 or XP
(Vista in compatability mode)O/S, is required with the software to
configure this unit before operating.
CHK GridSense PowerMonic PM20 Power Quality Analyser
CHK,PM20 MY
Three phase, weatherproof IP65 field unit. Three
voltage channels 63V to 440V (isolated). Four
current channels 0 to 3kA RMS (3ph & neutral).
Supplied with 3 x 1kA clamp-on CTs (cable
capacity 50mm), 3kA for large conductors and
500A for neutrals clamp-on CTs are available.
Memory 4Mb. In-built 2 line LCD display. Records
V, A, pF, f(Hz), kW, kVA, kVAr, THD, total energy
and tariffs, high speed RMS waveform capture events outside
preset limits (10ms intervals). Software provides graphs and
summaries to PC. Download files while logging. RS232 interface.
PC using Win 95, 98 or NT4 O/S, is required with the CHK
POWERview software to configure this unit before operating.
Stay informed on T&M news,
application notes and case studies
with @TechRentals on Twitter
27
Electrical Power
www.techrentals.com.au
Power Analysers, Loggers & Recorders cont’d.
Power Analysers, Loggers & Recorders cont’d.
CHK GridSense PowerMonic PM40 Power Quality Analyser
Fluke 345 Power Quality Clamp Meter
CHK,PM40PQA (8708) AU
FLU,345 (8739) AU
Weatherproof IP65 field unit. Channels: 3 Voltage,
63 to 440V (isolated). 4 current 0 to 3,000A (3ph
and neutral) RMS. Supplied with 4 flexible 3,000A
clamp-on CTs (flexible CT length 600mm and
Diameter 190mm). Memory: 15Mb. Inbuilt Graphic
128x64 bits LCD display, 7 rows x 20 characters.
Records: V, A, pF, f(Hz), kVA, kVAr, kW, harmonics,
Inter harmonics, voltage and current imbalance
(THD and individual to 48th ) and Flicker. Total energy, tariffs,
maximum demands, and transient and sub-cycle disturbances.
Included software provides graphs and summaries to PC.
Download files while logging USB interface. A PC using Windows
95, 98, NT4, WIN2000 or XP O/S, is required with the CHK
PowerView software to configure this unit before operating.
For measurements on switching loads such as
variable frequency drives, electronic lighting and
UPS systems. Low-pass filter and high EMC immunity
design make unit ideal for noisy environments. 600V
CAT IV rated, 1400A AC, 2000A DC. Measure and
log harmonics, inrush current and ripple current on
battery systems. Analyse data and generate reports
with included Power Log software.
CHK GridSense PowerMonic PM45 Power Quality Analyser
CHK,PM45 (8709) AU
Suitable for low voltage investigations, power
profiling and load studies, harmonic analysis,
power factor studies & flicker and imbalance
monitoring. Features IEC61010 Cat IV 600V safety
certificate, weatherproof IP65 case, 4 channel
voltage and 4 channels current. Supplied with
4 x Flexi F3000-6 clamps. VA, B & C, 0 to 600VAC
Vgnd 0 to 60VAC, Current input 0 to 3,000A.
Dranetz-BMI Power Guide 4400
DRA-BMI,PG4400 (8715) AU
Provides the full range of measurements
including V, I, W, VA, VAR, TPF, DPF,
demand, energy, harmonics & interharmonics, THD, harmonics spectrum
(V, I, W) to the 63rd, flicker (Pst, Plt), crest
factor, K factor, transformer de-rating etc. Asset comes with AC
flexible current clamp DRA-BMI,RR3035A/24, current range
30/300/3,000A AC only. Can be extended to different ranges of
measurement AC/DC by selecting appropriate current clamps.
Has the full range of arithmetic, vector and sequence parameters
to evaluate distorted and un-balanced loads as defined in IEEE
1459. Exceeding high/low limits of any active parameter can
trigger logging. Voltage & current disturbances. DRA-BMI,PG4400
analysers can be used for power quality measurements, current
inrush fault recording long term monitoring and continuous
logging at 1s intervals. DRA-BMI,PG4400 is Class A compliant
with IEC Standard 61000-4-30, AS61000-4-7 and AS61000-4-15.
Fluke 435 3-Phase Power Quality & Energy Analyser
FLU,435 (8738) AU/MY
Power Quality Analyser to suit a broad range of
AC mains studies. Includes 4 x 600/6000A AC
CTs. A unique energy loss calculator provides
the ability to monetarily quantify energy losses.
Supplied with Fluke Power Log Software for
detailed data analysis and report generation.
Optional accessory: FLU,I5SPQ3 (3 x i5s 5A AC current clamps).
Fluke 1735 3-Phase Power Logger
FLU,1735 (8737) AU/MY
Measures single-phase to 3-phase 4-wire
circuits, 50/60Hz. 3 voltage inputs with
common neutral rated 600Vac (CAT III 600V).
4 current inputs, 4 flexible current probes
(15A to 3000A) are included. Records voltage,
current, power (P, Q & S), power factor,
frequency, energy consumption, averaged demand, harmonics
(odd up to 25th order), THD (voltage & current). Includes built-in
batteries for up to 12 hours of recording, and includes Fluke
Power Log software.
Fluke VR1710 Single-Phase Voltage Quality Recorder
FLU,VR1710 (8720) AU
Single phase power quality analyser. Records
RMS, transients, flicker & harmonics up to
the 32nd. Selectable logging periods from
1s to 20min. Provides continuous recording
with no gaps. Includes software for download,
analysis and automatic reporting.
Hioki 3169-21 Clamp-On Power HiTester with 4 x 500A CTs
HIO,3169-21 CT500AMP (8726) AU
Dranetz-BMI Power Xplorer PX5
DRA-BMI,PX5 (8716) AU
Provides the full range of measurements
include V, I, W, VA, VAR, TPF, DPF,
Demand, Energy, Harmonics & Interharmonics, THD, Harmonics spectrum
(V, I, W) to the 63rd, Flicker (Pst, Plt), Crest
factor, K factor, Transformer de-rating etc. Min/Max/Avg values
are determined in 1/2 cycle RMS steps. Complete with A/C
Flexible Current Clamp DRA-BMI,RR3035A/24, Current Range:
30/300/3,000A AC only. Can be extended to mentioned different
ranges of measurement both AC/DC by selecting appropriate
current clamps. High-speed transient capture (1MHz sampling
rate). Pre-event and post-event waveform capture cycles are
user adjustable. Can be used for power quality measurements,
current inrush (cycle-by-cycle current logging), fault recording
(cycle-by-cycle voltage logging), long term monitoring and
continuous logging at 1s intervals. Compliant with IEC Standard
61000-4-30 (Class A), AS61000-4-7 and AS61000-4-15.
28
Measures voltage, current, power, power
factor, harmonics and integrated values.
Simultaneously performs demand
measurements required for power
management and energy-saving. Range
0.05A to 500A. Includes 4 x clamp-on CTs. Supplied software
provides graphs and summaries to PC. Flash card data storage.
RS232 interface for PC communications.
Hioki 3169-21 Clamp-On Power HiTester with 4 x 1,000A CTs
HIO,3169-21CT1000AMP (8727) AU
Measures voltage, current, power, power factor, harmonics
and integrated values. Simultaneously performs demand
measurements required for power management and
energy-saving. Range 5A to 1000A. Includes 4 x clamp-on CTs.
Supplied software provides graphs and summaries to PC.
Flash card data storage. RS232 interface for PC communications.
Rental vs Purchase
Why rental is more cost effective than ownership
When weighing up whether to purchase or rent, it is clear that the benefits of rental far
outweigh the cost of ownership. Not only does rental save you money, but it’s the smarter
business option, providing you with greater flexibility and control. At the end of your rental
period, simply return the equipment and upgrade to a newer version, it’s that easy!
3 Rental costs can be 100% tax deductible#
3 Immediate replacement of faulty equipment
3 No capex account process required
3 Avoid obsolescence
3 No depreciating assets
3 Ongoing service and technical support
Please see the chart below which illustrates the benefits of rental
over ownership for the Megger MOM2 Micro-ohmeter
Megger MOM2 Micro-ohmeter
$15,920
Purchase
$3,520
Rental
$ 0
5,000
techrentals
10,000
15,000
For more info call us
on 1800 632 652
20,000
Figures displayed represent costs at the end of the first year.
All rental rates quoted are based on a 3 year period.
Purchase Price
Service, Repair and Calibration (12%)
Cost of money (8%)
Depreciation
Net Rental (after tax deduction of $724 per year)#
Rental vs Ownership for the Megger MOM2 Micro-ohmeter
$
25,000
Cost of Ownership
15,000
Cost of Rental
vs
This graph illustrates the money saved when choosing
rental over ownership based on a 3 year period.
20,000
Total
$20,979
$13,267
$10,559
10,000
5,000
0
$6,991
$3,520
Capital
Year 1
$6,913
$3,520
Year 2
$3,520
Year 3
Cost of
Ownership
#Please ensure you obtain independent professional taxation advice. Prices shown are accurate as of date of publication and are subject to change.
Terms and conditions of rental apply as shown on www.techrentals.com.au. Prices exclude GST. Figures shown have been rounded to the nearest dollar.
Cost of
Rental
5/11/2014
TR1258
$7,076
Electrical Power
www.techrentals.com.au
Power Analysers, Loggers & Recorders cont’d.
Power Analysers, Loggers & Recorders cont’d.
Hioki 3169-21 Clamp-On Power HiTester with 4 x 5,000A FlexCTs
Hioki 3196 Power Quality Analyser with 4 x 1,000A CTs
HIO,3169-21CLAMPONPT (8728) AU
HIO,3196PQA-CT1000A (8730) AU
Measures voltage, current, power, power factor, harmonics and
integrated values. Simultaneously performs demand measurements
required for power management and energy-saving. Range 5A to
5000A. Includes 4 x flexible CTs, 500/5000A switchable. Supplied
software provides graphs and summaries to PC. Flash card data
storage. RS232 interface for PC communications.
Hioki 3196 Power Quality Analyser with 4 x 5,000A Flex CTs
High speed field unit, measuring transient
and sub-cycle disturbances, total energy,
tariffs and max demand. Four voltage
(150~600V RMS), and 4 current (0 to 1kA),
channels. Supplied with 4 clamp-on CTs.
Memory 512MB flash card. Colour display.
Records V, A, pF, f(Hz), kVA, kVAr, kW, harmonics, and
flicker. Supplied software provides graphs and summaries
to PC. RS232 or LAN interface for PC communications.
HIO,3196-PQA (8729) AU/MY
High speed field unit, measuring transient and
sub-cycle disturbances, total energy, tariffs
and max demand. Voltage (150~600V RMS),
and 4 current (0 to 5kA), channels. Includes 4
x flexible CTs, 500/5000A switchable. Records
V, A, pF, f(Hz), kVA, kVAr, kW, harmonics, and
flicker. Memory 512MB flash card. Colour display.
Supplied software provides graphs and summaries to PC.
RS232 or LAN interface for PC communications.
Hioki PW3198 Power Quality Analyser including 3 x 1000A,
1 x 200A AC/DC & 4 x 5000A Flex CTs
HIO,3198 (8732) AU
Premium Power Quality Analyser for
demanding applications. Includes 3 x
1000A ac CTs, 1 x 200A ac/dc CT and
4 x 9667 5000A flexible CTs. Ideal
for AC mains studies as well as solar
inverter evaluations. Supplied with Hioki 9624 PQA-HiVIEW
Software for detailed data analysis and report generation.
QUALITY PRODUCTS
QUALITY RESULTS
PW3198 Power Quality Analyser
00V
Cat IV 6
A
s
s
la
C
3554
Battery HiTester
PW3365-20 Power Analyser
Power Analysis
Load Profiling
Event Monitoring
Harmonics Analysis
Multiple Chemistry Battery Testing
16 Channel Measurement
High Speed Recording
CAN signal recording
Power Parameters Pty Ltd
83 Northern Road, Heidelberg West, Vic 3081
www.parameters.com.au power@parameters.com.au
Freecall: 1800 623 350 Freefax: 1800 067 263
MR8875
Memory HiCorder
Electrical Power
www.techrentals.com.au
Current Clamp Probes & Accessories
Current Clamp Probes & Accessories cont’d.
See also Electrical Testers on page 24
See also Power Analysers & Recorders on page 27-30
Hioki 3285 AC/DC Clamp-on Meter with Analog Output
CHK 3 Phase Converter for CTs 1A Input to 200mA Output
CHK,CR100 (8753) AU/MY
Ranges 200A/2kA AC/DC. Measure volts, ranges
30V, 300V & 600V AC/DC. Frequency ranges 10Hz,
100Hz & 1kHz. Display LCD, counts max 2,500
current, 3,750 voltage and 1,250 frequency. Output
voltage 1V for 2,000 count FS for each current range,
can select Rec RMS output, response time about
250ms rise time, fall about 500ms. Waveform output.
1V is produced for 1,000 count on FS frequency
range. Output not available for voltage measurements.
Supplied with signal output cord, 4mm to BNC convertor, carry
case and AC adaptor. Powered with internal 9V battery or AC
adaptor. (AC adaptor not supplied) adaptor.
Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as
fourth CT to measure neutral current. Accuracy Class 1.
Hioki 3290 Clamp-On AC/DC HiTester
CHK,CK1 (8751) AU
Adaptor for CTs with 1A secondary outputs, this unit suits
CHK,PM30/20.
CHK 3 Phase Converter for CTs 5A Input to 200mA Output
CHK,CK5 (8752) AU
Adaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.
CHK CR100 Clamp-on CT
CHK CR500 Clamp-on 500 CT
CHK,CR500 (8754) AU
Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as
fourth CT to measure neutral current. Accuracy Class 1.
HIO,3285 (8781) AU
HIO,3290 MY
Current Measurement at DC and from 1Hz
AC to 1,000Hz. Current Clamp Hioki 9693
Clamp-on AC/DC sensor ranges: 20A, 200A
& 2,000A, jaw opening 55mm.
Dranetz TR2510 Current Clamp Probe 0 to 10A RMS
DRA-BMI,TR2510 (8766) AU
Hioki 9660 Clamp-on 100A AC CT
Set of 4 current clamp/probes, range 0 to 10A RMS. Max
conductor size 12mmØ. Suitable for power quality analysers
DRA-BMI,PG4400, DRA-BMI,PX5 and DRA-BMI,PX5-400.
For current measurement through CT current transformer.
CT ratio can be selected on the above mentioned models.
HIO,9660CT100A (8783) AU
Rated primary current 100A AC. Amplitude accuracy: ±0.5% rdg.
±0.2%FS (at 45 to 66Hz). 66Hz-5kHz ±1% or less. Max circuit
voltage 300V RMS/insulated wire. Core jaw: 15mmØ.
Size: 46w x 21d x 135hmm, cord length 3m.
Fluke 376 True-rms AC/DC Clamp Meter with iFlex
FLU,376 (8770) AU/MY
Hioki 9661 CCT-500A Clamp-On Sensors 500A, 500mVAC Output
1,000A AC and DC current measurement with
fixed jaw. 2500A AC current measurement with
the 45cm iFlex flexible current probe. 1000V AC
and DC voltage measurement. Voltage and current
measurements are true rms. Includes ability to
measure frequency, resistance and capacitance.
Rated CAT IV 600V and CAT III 1000V.
HIO,9661 CCT-500A (8784) AU
Fluke 90I-610S 1A to 600A AC/DC Current Probe
FLU,90I-610S MY
Compatible with any Fluke scopemeter test tool,
power harmonics analyser, oscilloscope, multimeter
or other voltage measurement device that has the
following feactures: BNC input connectors or if using
a meter a BNC to banana plug adaptor PM9081/001
(included) lets you use this probe with your DMM.
Fluke i5sPQ3 AC Current Clamps, 5A (3 x i5S per set)
FLU,I5SPQ3 (8790) AU
A pack of 3 pieces of the i5s 5A AC current clamps,
specially configured to provide low current accuracy while
taking measurements on secondary current transformers.
CAT III 600 V (For insulated conductors only). Suits the
Fluke 435 and other instruments with BNC inputs.
Hioki AC/DC Clamp on Meter with Analog Output 20/200A
HIO,3284 (8780) AU
Can also measure volts, ranges 30V, 300V, 600V AC/DC. Frequency
ranges 10Hz, 100Hz, 1,000Hz. Display LCD, counts max 2,500
current, 3,750 voltage, 1,250 frequency. Output voltage 1V for 2,000
count on FS for each current range, can select Rec rms output,
response time about 250ms rise time, fall about 500ms. Select Mon
for waveform output. 1V is produced for 1,000 count on FS frequency
range. Output not available for voltage measurements. Supplied with
signal output cord, 4mm to BNC convertor, carry case and AC adaptor.
Note: Can be powered with internal 9V battery or AC adaptor.
(AC adaptor not supplied.)
500A rated, 500mVAC FS output, core jaw
46mmØ. Designed with a safety barrier to
protect the user from being in direct contact
with live conductors and completely meets all
CE marking requirements. Basic specifications:
Rated input current 500A AC, rated output current 0.5VAC,
accuracy (at 45 to 66Hz), amplitude: ±0.5% rdg ±0.2% FS is the
3196 range value, phase: ±0.5° or less, frequency characteristics
66Hz to 5kHz (±1% or less from accuracy), max allowable
input continuous 550A RMS (45 to 66Hz), max circuit voltage
600VAC RMS (insulated wire), core jaw Ø46mm, dimensions,
mass 77mm W x 151mm H x 42mm D, 360g, cord length 3m.
Hioki 9661-01 CCT-500A Clamp-on Sensors
HIO,9661-01 CCT-500A (8785) AU
500A rated, 500mVAC FS output, jaw
46mmØ. Rated input current 500A AC, rated
output 0.5VAC, accuracy (at 45 to 66Hz).
Amplitude ±0.5%rdg, ±0.2%FS. FS is the
3196 range value, phase ±0.5° or less,
frequency characteristics 66Hz to 5 kHz (±1%), max. Allowable
input continuous 550A RMS (45 to 66Hz), max circuit voltage
600VAC RMS (insulated wire). Dimensions 77mm W x 151mm
H x 42mm D, cord 3m. Suitable for Hioki models: 3196PQA,
3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01,
any data logger/scope which takes up to 1.7mVAC input.
New items are being added to the inventory
constantly, so if you cant see what you’re
looking for, please call us on 1800 632 652.
31
Electrical Power
www.techrentals.com.au
Current Clamp Probes & Accessories cont’d.
Insulation Testers & Meggers to 20kV cont’d.
Hioki 9669-CCT-1000A Clamp-on Sensors
Kikusui TOS-5101 10kV AC/DC Hipot Tester
HIO,9669-CCT-1000A (8787) AU
KIK,TOS-5101 (8430) AU
Jaw 55mmØ, 80mm x 20mm busbar.
Rated input current 1,000A AC, rated
output current 0.5VAC, accuracy (at 45
to 66Hz) amplitude ±1% rdg, ±0.01% FS,
FS is the 3196 range value, phase ±1° or less, frequency
characteristics 66Hz to 5kHz (±1%), max. Allowable input
continuous 1,000A RMS (45 to 66Hz), max circuit voltage
600VAC RMS (insulated wire). Dimensions 99.5mm W x 188mm
H x 42mm D, cord 3m. Suitable for Hioki models 3196PQA,
3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01,
any data logger/scope which takes up to 1.7mVAC input.
Hipot testing up to 10kV in either DC or AC. Digital
voltmeter and ammeter, digital timer. Window
comparator for more reliable pass/fail judgement.
Automatic discharge of device under test in DC test mode.
Equipped with Key Lock and Interlock functions for greater safety.
Hioki 9694 Clamp-on CT 5A
HIO,9694CT5A (8789) AU
Rated primary current 5A AC. Amplitude accuracy ±0.5% rdg.
±0.2% FS (at 45 to 66Hz), 66Hz to 5kHz ±1% or less.
\Max circuit voltage 300V RMS/insulated wire.
Core jaw 15mmØ. Size mm: 46w × 21d × 135h, cord length 3m.
Megger MIT525 5KV DC Insulation Resistance Tester
MEG,MIT525 (8426) AU/MY
Measures to 20TΩ at 5kV. Tests include PI, DAR, DD, SV
and ramp test. Li-ion battery with rapid charge, mains
operation possible while battery is charging. Advanced
memory with date/time stamp. Noise filter rejects up to
3mA noise. PowerDB Lite asset management software
supplied with unit for download of test data to a PC.
Megger MIT1020 Diagnostic 10kV Insulation
Resistance Tester
MEG,MIT1020-10KV DIT (8423) AU
Insulation Testers & Meggers to 20kV
EA Technologies UltraTev Plus Partial Discharge Detector
EAT,ULTRATEVPLUS (8410) AU
Multi-function Partial Discharge (PD) Instrument. It
measures accurate PD activity using the UltraTEV
detector and an ultrasonic detector. It gives you
an objective measure of the level of activity. Will
display PD severity level. The kit includes the
Ultradish for measurement of overhead assets.
Fluke 1587 Insulation Multimeter
FLU,1587 MY
Insulation: measurement range: 0.01M to 2GΩ. Test Voltages:
50V, 100V, 250V, 500V, 1,000V Multimeter: Voltage 1mV to
1,000VAC/DC, current 0.01mA to 400mA AC/DC, resistance
0.1Ω to 50.0MΩ, capacitance 1nF to 9999μF, frequency
0.01Hz to 99.99kHz.
Fluke 1653 Electrical Installation Tester
FLU,1653 MY
Tester verifies the safety of electrical
installations, according to IEC 60364, HD
384 standards. Functions available: voltage and frequency
measurement, insulation resistance testing, continuity testing,
loop impedance, RCD tripping time, RCD tripping current, earth
resistance and phase sequence.
Hioki 3455 High Voltage Insulation Tester
HIO,3455HVIT-5kV (8411) AU/MY
PI (Polarisation Index) and DAR (Dielectric
Absorption Ratio) function to check insulation
quality and step voltage test to detect for signs
of deterioration. Generates test voltages from
250V to 5kV in commonly used presets of
250V, 500V, 1kV, 2.5kV & 5kV, or set to desired
level by increments or decrements of 25V
or 100V. Insulation diagnoses for automatic calculation and
indication of PI and DAR, step voltage testing and temperature
correction. Large memory stores up to 100 manual records and
a logging function for 10 data (360 times). Stored data with
date and time may be displayed on the LCD or down-loaded.
32
Backlit display, variable test voltage from 50V to 10,000V,
Automatic IR, PI, DAR, SV and DD tests, measures to
35T, RS232 and USB download of results. IEEE 43-2000
recommends the use of 10kV for motor windings rated above
12kV. Protection rating of IP54. Mains or battery powered.
Megger MIT1025 10 kV DC Insulation Resistance Tester
MEG,MIT1025 (8427) AU
10kV DC Insulation Resistance Tester. Measures
to 20TΩ at 10kV. Tests include PI, DAR, DD, SV
and ramp test. Li-ion battery with rapid charge,
mains operation possible while battery is charging.
Advanced memory with date/time stamp.
Noise filter rejects up to 3 mA noise.
PowerDB Lite asset management software supplied
with unit for download of test data to a PC.
Megger MIT1525 15 kV DC Insulation Resistance Tester
MEG,MIT1525 (8428) AU
Measures to 30TΩ at 15kV. Tests include PI, DAR,
DD, SV and ramp test. Li-ion battery with rapid
charge, mains operation possible while battery is
charging. Advanced memory with date/time stamp.
Noise filter rejects up to 6mA noise. PowerDB Lite
asset management software supplied with unit for
download of test data to a PC.
Megger S1-1052 High Current Insulation Resistance Tester 10kV
MEG,S1-1052 10KV-DIT (8424) AU/MY
High output current 5mA for fast charging of
capacitive loads. Testing up to 10kV, mains or
battery powered, digital/analogue backlit
display, variable test voltage from 50V to
10,000V, automatic IR, PI, DAR, SV and DD tests.
Measures to 35TΩ. RS232 and USB download of results.
Megger S1-552 High Current Insulation Resistance Tester 5kV
MEG,S1-552 5KVDIT (8425) AU
High output current 5mA for fast charging of
capacitive loads. Testing up to 5kV, mains
or battery powered, digital/analogue backlit
display, variable test voltage from 50 to 5,000V,
automatic IR, PI, DAR, SV and DD tests.
Measures to 15TΩ. RS232 and USB download of results.
Electrical Power
www.techrentals.com.au
Oil, Hipot & VLF Testers above 20kV
Oil, Hipot & VLF Testers above 20kV cont’d.
Hipotronics 880PL-10MA-B 80kV DC Hipot Tester
HV Diagnostics HVA60 60kV VLF/DC Test Set
HIP,880PL (8491) AU
HVD,HVA60-DC/VLF (8462) AU
Compact, portable unit (41kg) for DC field
testing of cables, terminations, motors,
generators and other electrical apparatus.
80kV 10mA output capability with
multirange voltmeter and ammeter.
For operator safety the power supply
and test object are automatically grounded when high
voltage is turned off, and there is no exposed high voltage.
Guard circuit for accurate leakage current measurement.
Includes overload relay and surge limiting resistors in HV output.
VLF and DC test capabilities combined in
one unit (60kg). Suitable for testing cables,
capacitors, switchgear, transformers, machines,
insulators and bushings. VLF (0.1Hz to 0.02Hz),
DC (±), cable fault conditioning (burning) and
sheath/jacket testing modes all included.
Fully automatic or manual cable test sequences.
True symmetrical sinusoidal, load independent, output waveform
across the full load range. Real-time display of actual output
wave form. Large output load capability (up to 5µF). Automatic
and integrated load capacitance measurement with optimum
frequency selection. Storage of test results for later retrieval
or download to a PC/Laptop. For a more comprehensive
understanding of insulation condition perform tan delta testing
at the same time with optional accessory HVD,HVA TD60.
High Voltage Inc PFT503, 50kV AC Test Set
HIV,PFT503 (8453) AU
Single, portable (34kg) unit suited for testing overhead
apparatus, vacuum bottles and interrupters, switch gear, bus
duct, motorized vacuum switches, reclosers, bushings, fuses and
arrestors, linemans safety products, small transformers, electrical
components and motors. This 3kVA model features capacitive
load compensation enabling full load testing with a power draw
of 1.5kVA while operating from a conventional line input. 60mA
output current capability.
High Voltage Inc PFT-1003CMF 100kV AC Hipot Test Set
HIV,PFT1003 (8456) AU
Portable (16kg control unit, 39kg HV tank)
hipot tester, 100kV, 50Hz, rated 3kVA into
capacitive loads. Features continuously
adjustable output voltage, external safety
interlock, zero start safety interlock, self
resetting over current protection, guard/
ground return mode, HV on/off and main
power push button ruggedized meters and
with glass windows that eliminate static buildup.
HV Diagnostics HVA TD60 Portable TanDelta Measurement System
HVD,HVA TD60 (8460) AU
Optional Accessory for HVD,HVA60-DC/VLF and
HVD,HVA90_DC-VLF. Tan Delta or Power Factor
tester used to determine the power factor of cables,
transformers, capacitors, rotating machines and
other switchgear. This test allows the detection of
insulation defects before they fail inservice.
HV Diagnostics HVA30 30kV-15mA DC/VLF High Voltage
Insulation Dielectrics Test Set
HVD,HVA30-DC/VLF (8461) AU/MY
VLF and DC test capabilities combined in one
unit (20kg). Suitable for testing cables (XLPE,
PE, EPR, PILC etc), capacitors, switchgear,
transformers, machines (IEEE 433), insulators
and bushings. VLF (0.1Hz to 0.02Hz), DC (±),
cable fault conditioning (burning) and sheath/
jacket testing modes all included. Fully automatic or manual
cable test sequences complying with International Standards/
Guides such as IEEE 400.2, VDE 0276 and CENELEC.
True symmetrical sinusoidal, load independent, output waveform
across the full load range. Real-time display of actual output
wave form. Easy to use, ergonomic, menu guided, large backlit
user interface. Large output load capability (up to 5uF).
Automatic and integrated load capacitance measurement
with optimum frequency selection. Storage of test results
for later retrieval or download to a PC/Laptop.
HV Diagnostics HVA90 90kV VLF/DC Test Set
HVD,HVA90_DC-VLF (8463) AU
VLF and DC test capabilities combined in one
unit (127 kg). Suitable for testing cables (XLPE,
PE, EPR, PILC etc), capacitors, switchgear,
transformers, machines (IEEE 433), insulators
and bushings. VLF (0.1Hz to 0.01Hz), DC
(±), cable fault conditioning (burning) and
sheath/jacket testing modes all included.
Fully automatic or manual cable test sequences complying with
International Standards/Guides such as IEEE 400.2, VDE 0276,
CENELEC HD620 S1, NEN 3620, SANS 10198 and IEC 60060-3.
True symmetrical sinusoidal, load independent, output waveform
across the full load range. Real-time display of actual output wave
form. Easy to use, ergonomic, menu guided, large backlit user
interface. Large output load capability (up to 10uF). Automatic
and integrated load capacitance measurement with optimum
frequency selection. Storage of test results for later retrieval or
download to a PC/Laptop. Optional Accessories: HVD,HVA TD60.
Megger OTS80PB Transformer Oil Tester Insulation
Dielectrics Test Set
MEG,OTS80PB (8450) AU/MY
Test voltage 80kV max at 61.8Hz.
Fully automatic operation.
Rechargeable batteries. RS232C interface.
Phenix BK130 130kVAC Hipot Aerial Lift Test Set
PHE,BK130 (8480) AU
Tests elevating boom as well as the work platform
and linings to ANSI A92.2 draft standard. Can also
be used in many other Hipot applications that require
the sort of voltage and current this instrument is
capable of. Can supply 0 to 130kVAC @ 50mA and
0 to 35kVAC at 171mA. The whole system is built
into a trolley cart for ease of use. Measurement
accuracy 1% FS for 10 to 100% of range.
Learning to operate unfamiliar equipment
costs you time and can lead to errors.
Save time and reduce your real costs.
Find out all about our Configuration
and Download solution on page 37
33
Electrical Power
Transformer Testers
Megger CAL 300 IDAX Calibration Box
www.techrentals.com.au
Transformer Testers cont’d.
Omicron Dirana Transformer Insulation Moisture Analyser
MEG,CAL300 (8551) AU
OMI,DIRANA (8557) AU
Exclusively used for calibration of Megger IDAX
Insulation Diagnostic Analysers.
Provides an accurate and reliable condition
assessment of insulation in transformers,
bushings, generators and cables. It utilises Dielectric Frequency
Response in combination with analysis in software to determine
the percent of moisture in paper insulation, oil conductivity and an
individually corrected tan delta value at 20°C reference temperature.
The unit is provided with a laptop pre-loaded with all software.
Megger IDAX 300 Insulation Diagnostic Analyser
MEG,IDAX300 (8552) AU
Provides an accurate and reliable condition
assessment of insulation in transformers,
bushings, generators and cables. It utilises Dielectric Frequency
Response in combination with analysis in software to determine
the percent of moisture in paper insulation, oil conductivity and an
individually corrected tan delta value at 20°C reference temperature.
Circuit Breaker Testers
Megger TM1760 Circuit Breaker Analyser System
MEG,TM1760 (4670) AU
Megger MTO330 Automated Six Winding Transformer Ohmmeter
MEG,MTO330 (8553) AU
Delivers full eight-terminal/six-winding resistance
measurement capability. It is designed to save
time by testing all six windings without having
to disconnect and reconnect leads. Also, the
simultaneous winding magnetization method
gives fast and reliable measurements even on large transformers
with delta configuration on the low voltage side. The leads are
interchangeable with the Megger TTR320 three-phase turns ratio
instrument which eliminates additional connecting time for turns
ratio measurements (However, TTR320 leads must NOT be used
with the MTO330. The leads have a higher current rating). Includes
an on-board computer with QWERTY keyboard, USB and ethernet.
Megger TTR320 3-Phase Transformer Turns Ratio Test Set
Advanced Circuit Breaker Analyzer with built-in
PC and utilising DualGround method for safer
testing. Galvanically isolated inputs and outputs
makes it possible to perform all relevant
measurements in one test, eliminating the need
for new setup and re-connections. Includes 3 static & dynamic
resistance modules with up to 220A test current, a 3-channel
dynamic capacitance module and a full set of required cables.
Current Injectors
Megger CSU600AT Current Supply Unit with Timer Option
MEG,CSU600AT (4602) AU
600A current supply unit, including timer option.
Current supply, 100A @ 9.0V 1hr, 600A @ 6.5V 30s.
MEG,TTR320-47 (8554) AU
Accurately measures ratio, phase
deviation and exciting current on 3-phase
transformers in the presence of high noise.
Can test phase-PowerDB. Test results can
be stored and downloaded at a later time.
Handles ratios up to 45,000:1 with 0.3% accuracy, 0.1% up to
2,000:1. Compatible with the Megger MTO330 transformer
ohmmeter leads which eliminates additional connecting time for
turns ratio measurements (However, TTR320 leads must NOT be
used with the MTO330. The MTO330 leads have a higher current
rating). Includes an on-board computer with QWERTY keyboard,
RS232 and ethernet.
Omicron CT Analyser Current Transformer Analyser
Megger INGVAR Primary Current Injection Test System
MEG,INGVAR MY
Advanced primary current injection test system
to simplify all types of switchgear and CT
commissioning, ground grid, circuit breaker
testing and more. Up to 5,000A output current.
Two units, each of about 20kg, making it easier to carry.
(Supplied current cable supports up to 2,000A only).
Multi-Amp MS-2 High Current Test Set
MUL,MS-2 (4600) AU
Portable (8 kg) and automated unit for testing
protection and metering CTs on-site. CTs can be
verified up to the 0.1 accuracy class. The included
CT SB2 switchbox allows automated testing of CTs
with up to six taps. Remanence can be measured
and cores can be demagnetised.
Designed to test overload relays, circuit
breakers and earth fault trip devices. Input
240V 50/60Hz. Output continuously adjustable
in 4 ranges 120V/5A, 24V/25A, 6V/120A &
3V/240A. Short term over current of several times the rated
current ranges is possible. Digital current meter has read and
hold facilities for short duration currents. Digital timer measures
elapsed time between energisation and the test device operating.
Omicron FRA Frequency Response Analyser
Omicron CPC 100 Multi-functional Primary Test System
OMI,FRA (8556) AU
OMI,CPC100PTS (4620) AU
Uses swept frequency response analysis to
detect mechanical and electrical changes
of the core and winding assembly of power
transformers. By finding winding or core defects
after faults, mechanical shocks or transportation,
it offers a valuable opportunity to improve the
reliability of transformers, to reduce maintenance costs and to
avoid expensive, unexpected outages. Laptop included, preloaded
with the FRAnalyzer software.
Portable (29 kg) primary test system suited
for testing of current transformers, voltage
transformers, power transformers, power lines,
HV cables, grounding systems, switchgear and
circuit breakers, protection relays and more.
Tests to 800A (extended to 2000A with CP CB2) over frequency
range 15Hz to 400Hz, or to 400A DC. Laptop included, preloaded
with CPC 100 Toolset. Optional accessories: OMI,CPCU1 (with or
without OMI,CPSTEP) OMI,CPSB1 OMI,CP-TD1 OMI,CPCB2.
OMI,CTANALYZER (8555) AU
34
Electrical Power
Current Injectors cont’d.
www.techrentals.com.au
Protection Relay Testing Systems cont’d.
Omicron CP CB2 Current Booster
Omicron CMC256-6 Universal Relay Test Set
OMI,CPCB2 (4605) AU
OMI,CMC256-6 (4660) AU/MY
Combined with the CPC 100, the CP CB2 boosts the
output current of a CPC 100 from 800A to 2000A.
Omicron CP CU1 Multi-Purpose Coupling Unit for PC 100
OMI,CPCU1 (4623) AU
Combined with the CPC 100, the CP CU1 is a
measurement system for line impedances &
k-factors of overhead lines or power cables,
mutual coupling of parallel lines, ground impedances of large
substations and coupling of power lines into signal cables. This
test system overcomes the problem of power system frequency
interference that has previously made it necessary to use extremely
large, high-power equipment to carry out these measurements.
OMICRON Step & Touch Voltage Accessory Set
OMI,CPSTEP (4624) AU
Combined with the CPC 100 and CP CU1, this
kit is a measurement system for Step & Touch
voltages. The battery powered FFT Voltmeter
(CP AL1) operates with short leads and requires
no connections back to the CPC 100.
Omicron CPSB1 Switch Box
OMI,CPSB1 (4621) AU
Switch Box to allow fully automated 3 phase
transformer testing, accessory for the CPC100.
Omicron CP TD1 Capacitance and Tan Delta Add-on
OMI,CP-TD1 (4622) AU
Combined with the CPC 100, the CP TD1 measures
the capacitance and dissipation factor (power factor)
with laboratory precision. This allows the insulation
condition of transformers, generators and other parts
of high-voltage systems to be tested according to IEEE
62 (C57.152), IEC 60076-1 and -3, as well as the
CIGRE “Guide for Transformer Maintenance”. As recommended
in the CIGRE Guide, testing is performed at variable frequencies
to better diagnose signs of ageing in insulation. The portable test
system (max. 29 kg per component) can also generate output
voltages of up to 12kV. Trolley included.
T&R CIT/LU2000 Primary Current Injection Test Set
T&R,CIT (4603) AU
Comprises control unit and 2kA loading unit (LU).
Control unit includes timer, current and voltage
meters, and variable output transformer. External
loading unit output 0 to 2kA, duty 5min on 15min
off at 6VAC, continuous 0 to 1kA at 3VAC. Two
units weight 35 & 45kg plus 2 quad 70mm2 cable sets each 3m
long. Control unit connects to LU with supplied interface cable.
Protection Relay Testing Systems
Omicron CMA 156 Six Phase Current Amplifier (6 x 25A)
OMI,CMA156-6PCA (4655) AU
Can be used in combination with any CMC test set. The outputs
are galvanically separated from the inputs as well as from ground
and are used independently or in addition to those of the CMC
test sets. The six independent current channels are arranged
in two isolated groups (A, B). The outputs can be connected in
parallel or in series. The connection to a CMC test set is made by
a control cable at the back of the units. Used for tests requiring
more current channels than provided by the CMC test sets.
Protection relay test set and universal calibrator (energy meters,
measuring transducers, power quality measurement devices,
phasor measurement units etc) with six current sources (6 x 12.5A,
3 x 25A or 1 x 75A), four voltage outputs (4 x 300V or 1 x 600V),
4 x binary outputs, 10 x multifunctional binary inputs (dry/wet)
and Generator Combination Cable for wiring convenience. The six
current and four voltage output channels are continuously and
independently adjustable in amplitude, phase and frequency.
All outputs overload and short-circuit proof. LLO-2 option not
included. Laptop included, preloaded with Test Universe software
(Universal). Optional accessories: OMI,CMA156-6PCA OMI,CMGPS.
Omicron CMC 256plus Universal Relay Test Set
OMI,CMC256PLUS (4661) AU
Improved accuracy specifications. Protection
relay test set and universal calibrator (energy
meters of class 0.2, measuring transducers,
power quality measurement devices, phasor measurement
units) with 6 current sources (6 x 12.5A, 3 x 25A or 1 x 75A),
4 voltage outputs (4 x 300V or 1 x 600V), 4 x binary outputs,
10 x multifunctional binary inputs (dry/wet) and Generator
Combination Cable for wiring convenience. The 6 current and
4 voltage output channels are continuously and independently
adjustable in amplitude, phase and frequency. All outputs
overload and short-circuit proof. LLO-2 option not included.
Laptop included, preloaded with Test Universe software
(Universal). Optional accessories: OMI,CMA156-6PCA
Omicron CMC 356 Advanced Protection Relay Test Set
OMI,CMC356 (4656) AU
Protection relay test set with 6 current
sources (6 x 32A/430VA, 3 x 64A/860VA
or 1 x 128A/1000VA), 4 voltage outputs (4
x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional
binary inputs (dry/wet) and Generator Combination Cable for
wiring convenience. The 6 current and 4 voltage output channels
are continuously and independently adjustable in amplitude,
phase and frequency. All outputs overload and short-circuit
proof. Laptop included, preloaded with Test Universe software
(Advanced Protection + Transducer). Optional accessories:
OMI,CMA156-6PCA OMI,C-PROBE1 OMI,CMGPS
Omicron CMC 356 Advanced Protection Relay Test Set +61850
OMI,CMC356_61850 (4657) AU
Protection relay test set with 6 current
sources (6 x 32A/430VA, 3 x 64A/860VA
or 1 x 128A/1000VA), 4 voltage outputs (4
x 300V or 1 x 600V), 4 x binary outputs, 10 x multifunctional
binary inputs (dry/wet) and Generator Combination Cable for
wiring convenience. The 6 current and 4 voltage output channels
are continuously and independently adjustable in amplitude,
phase and frequency. All outputs overload and short-circuit proof.
Includes IEC61850 software package (GOOSE, Sampled Values,
IEDScout, SVScout). ELT-1 and LLO-2 options not included.
Laptop included, preloaded with Test Universe software (Advanced
Protection + Transducer) and IEC61850 package. Optional
accessories: OMI,CMA156-6PCA OMI,C-PROBE1 OMI,CMGPS
Omicron CMGPS Syncronisation Control Unit
OMI,CMGPS (4662) AU
Optional accessory for use with any OMICRON CMC test
set. Included are two GPS unit which provide a start
signal pulse based on the GPS clock time base. Software
is integrated in the testing modules (State Sequencer).
Can also be used as a stand-alone application.
35
Electrical Power
Protection Relay Testing Systems cont’d.
www.techrentals.com.au
Battery Management Systems
Omicron C-Probe-1 Clamp-on CT AC/DC
Hioki Battery HiTester
OMI,C-PROBE1 (4664) AU
HIO,3551BATTERYTEST (8275) AU
Optional accessory for OMI,CMC356 & OMI,CMC356_61850.
An active AC and DC current probe with voltage output.
Recommended accessory for measuring currents with the
CMC356. It has 10A and 80A measuring ranges, frequency range
DC to 10kHz. Accuracy error < 2% for currents up to 40A and
frequencies up to 1kHz. Phase error <0.50 @ 50/60Hz. Length
230mm. Output: 0-10A range 100mV/A, 0-80A range 10mV/A.
Megger (Programma) Sverker760 Relay Test Set
PRO,SVERKER760 (4672) AU
Relay test set for 1ph protective relay equipment. Three phase
relays can be tested 1 phase at a time or by synchronising more
than one unit. Current ranges to 100A with full load current
to 250A. AC outputs to 250V & DC outputs to 300V. In-built
capacitor and resistors for current output phase shifting. In-built
timer, ammeter, and voltmeter. Measures phase angle, PF, and
impedance. RS232 communications and control interface.
T&R DVS3-HP Static Relay Test System
T&R,DVS3-HP (4675) AU
Test system for testing voltage and frequency protection relays
and transducers. Tests Automatic Voltage Regulating (AVR) relays
with line drop compensation, under and over voltage relays,
directional over-current relays, df/dt (ROCOF) relays, vector surge
(step change of phase) relays and check synchronising relay.
Generates a 3ph voltage output from a 1ph supply, and may
be used in conjunction with a current source to test directional
protection. Requires 1ph 50/60Hz supply of 115V or 230V
(±15%). We only supply the DVS-T260 VT box (Ratio 1:2) which
has a maximum output voltage of 266V for a maximum load of
10VA per phase. Accuracy, Class 2 (±0.2% for 2.5 to 10VA load).
Takes on-the-spot measurements of
the internal resistance, voltage and
temperature of lead-acid batteries,
principally for UPS and similar applications, without needing
to shut off the battery. Instantaneous results, on a three-rank
scale of Pass, Warning, or Fail, using a composite decision
based on the internal resistance and the voltage. Resolution
of 1µΩ, necessary for high capacity batteries (of at least
500Ah). Includes Hioki 9460 clip type temperature leads.
Megger Torkel 840 Battery Load Unit
PRO,TORKEL-840 (8276) AU
Portable (22 kg, 38 kg with accessories and transport case)
battery discharge load unit. Works with 12V to 250V battery
systems and can discharge at up to 110A (15kW maximum
power). Can be programmed for constant current, constant
power, constant resistance or user defined load profiles.
The included DC current clamp allows on-load testing. Tests can
be PC controlled and results reviewed using the included TORKEL
Win software. The load current can be extended with the optional
accessory PRO,TXL870 extra load unit.
Megger (Programma) TXL870 Extra Load Unit
PRO,TXL870 (8277) AU
Optional accessory for the PRO,TORKEL-840
battery load unit. Adds up to an extra 112A
load capacity to a discharge test (15.8kW
maximum). Operates as a slave in combination
with a PRO,TORKEL-840 battery load unit.
AC Sources/Inverters/Generators
Chroma 61501 Programmable AC Power Source
CHR,61501 PAC-PS (6400) AU
PPower: 500VA. Voltage: 0-150V/0 to 300V/AUTO. Compact
size and weight attributable to advance PWM technology.
AC, DC, AC+DC output mode. Programmable output impedance
for IEC 61000-3-3. IEC 61000-4-11 voltage dips and variation
simulation. Harmonics, inter-harmonics waveform synthesizer
for IEC 61000-4-13 testing. Power line disturbance simulation
capability. Programmable voltage, current limit. Comprehensive
measurement capability, including current harmonics. High output
current crest factor, ideal for inrush current testing. Turn on,
turn off phase angle control. TTL signal which indicates output
transient. Software for IEC regulation test. Analog programmable
interface. Optional GPIB and RS232 interface fitted.
Power Transformers & Variacs
Get the job done right the first time.
Our technical team has the expertise to
find the perfect solution for your test and
measurement requirements.
And to give you peace of mind,
TechRentals also provides a 24 hour “NO
RISK GUARANTEE”. Should the rental item
be unsuitable for your application, simply
return it to us complete within 24 hours.
Dimmer Dot 0-270V AC, 17A Variac
DIM,D201P (8230) AU
Single phase variac. 240 V AC input, 0-270V AC
output at 17A. Input and output connections must
be wired up under a protective cover.
Dimmer Dot Variable AC Voltage Auto Transformer 3 Phase 23-28A
VAR,D-283-OB (8229) AU
Manual operated air cooled; Input 400/415V, 50Hz. Output 0 to
415/470V. 23 to 28A. Total Weight 95kgs.
36
techrentals
Setup and Download
Save time and reduce your costs by using our data management services. Learning to operate
unfamiliar equipment costs you time and can lead to fundamental errors in the data capturing
processing. Use a better solution - our setup and download service.
Our technical staff are equipped and trained to deliver you the downloaded data in a range of suitable output formats
including USB drive, CD-ROM, printout, chart and DVD according to your need and the product’s functionality.
When you nominate your output preferences and appropriate technical information, the rest is taken care of.
The completed files or printouts will be forwarded to you quickly or may be collected at an arranged time.
Equipment marked with the
symbol is available to rent with this service. Fees vary depending on the complexity
of operation and the level of detail involved.
Data management services are available for many products. Below are some examples of what you can expect.
Seward ProTag Optima 300
Testing and Tagging System
CHK PM30/PM30PLUS - 3 CT Power Quality Analyser
CHK PM40/PM45 - 4 CT Power Quality Analyser
Model: SEW,PT-300
Model:
CHK,PM30
CHK,PM30PLUS
CHK,PM40PQA
CHK,PM45
Setup:
• Load logo file in printer
• Load test settings
Results Downloaded:
• Provide database in PATGuard format
• Provide CD with PATViewer software including database for end customer
Results Downloaded:
• Raw Data
• PowerView Software
• PDF report of V and I Trend Graph
• Total kWh Calculation
• Exported Data as CSV or
Excel files
Fluke DSX-5000 Cable Analyser
Model: FLU,DSX-5000
Setup:
• Company name
• Site
• Tester
• Setup of certification test limit
• Cable type/fibre type
Results Downloaded:
• Raw Fluke Linkware files
• Linkware software
• PDF report results
Flir E60-II Thermal Camera
Model: FLI,E60-II
Hioki LR8431-20 10 ch Memory Logger
Model: HIO,LR8431-20
Setup:
• How many channels to be
measured (out of 10 channels)
• Each channels measurement.
e.g. voltage, current, etc.
• Channel scaling
• Period of logging to determine
logging interval
• Logging Interval
Results Downloaded:
• Data results
• Logger Utility Software
TR1148
Results Downloaded:
• Raw image files
• Relevant editing software
• Adjust isotherm and emissivity
• Standard report of images
Setup:
• 3P4W(star) or 3P3W(delta)
• Max. Current (<1000 A or <3000 A)
• 3 Phase Current only or 3 Phase and Neutral
• Log Period and Log Interval
• Log Profiling (V, I, pF, kWh, THD)
• Event Capture
(Sag, Swell, Transient)
• Start Log Next Power up
For more information call us on 1800 632 652 or email us at rent@techrentals.com.au
General Industrial
www.techrentals.com.au
Temperature Meters/IR Thermometers
Infrared Thermal Imaging Cameras
Endoscopes Borescopes Visual Inspection
High Speed Video Inspection Cameras
Tachometers/Stroboscopes
Laser Rotational Shaft Alignment
Industrial Process Calibrators
Wet & Dry Block & Calibrators
Strip Chart Recorders
High Speed Waveform Recorders
Data Loggers
Pressure Vacuum Gauges/Recorders
Flow Meters for Liquids & Gases
Combustion, Flue & Industrial Gas Analysers
Temperature Meters/IR Thermometers
Fluke 52-2 Digital Thermometer
FLU,52-2 MY
Dual input thermocouple thermometer supplied
with two K type thermocouples for differential
measurements. Sampling rate of 1Hz (1 probe) or
1.7Hz (2 probes). Will continuously record max and
min measurements. It also can take K,J,T and E type
Thermocouple inputs. Temperature range: K type:
-200°C to 1,372°C.
Fluke 54-2B 2 Channel Data Logging Temperature Meter
with FlukeView
FLU,54-2B-FVF (4507) AU/MY
Dual input digital thermometer with data logging.
Will take most TC inputs. Accuracy ±0.05% of reading
+0.3ºC. 500 point logging with date & time stamp.
Also records min, max or avg. Logged data can be
reviewed on meter or downloaded to PC using software
included. Supplied with 2x 1m K type thermocouple
leads -200 to 800°C.
Fluke 80TK Thermocouple Module
FLU,80TK (4531) AU
Use with DVM’s and recorders. Accepts K
thermocouples. Temperature range -50 to 1,000ºC.
Output 1mV/ºC. Type 80KP-1 probe included.
More Detail and More Choices
for Faster Troubleshooting and Reporting
Experience the Power of FLIR Thermal Imaging
From the handy E4 to the well-connected E60
and the incredibly ergonomic T-Series, all FLIR
handheld infrared cameras come standard with
our patented MSX® technology. MSX adds key
visible details to your images without diluting
their thermal integrity – details such as numbers,
labels, and other recognizable features help
you instantly identify where potential problems
are heating up.
Along with MSX, FLIR cameras from the E40 up
feature the speed of user-friendly touchscreens
and built-in wireless communication. Send
readings from compatible FLIR METERLiNK®
test instruments right to the camera and embed
extra measurement data into thermal images
automatically. Connect cameras via Wi-Fi to
smartphones and tablets with FLIR Tools Mobile
for quick processing and fast image sharing from
the job site to get repair decisions sooner.
FLIR Systems Pty Ltd.
VIC: 03 9550 2800 NSW: 02 8853 7870 WA: 08 6263 4438
Tel AU: 1300 729 987 NZ: 0800 785 492 Email: info@flir.com.au
www.flir.com.au/techrental
38
FLIR cameras set a new benchmark in
affordable, feature-packed thermal imaging
technology – perfect for electrical/mechanical
inspections, HVAC and plumbing applications,
building diagnostics, and more.
*See warranty and registration details at flir.com
FLIR MSX® Embosses Thermal images with Visible Detail
ISO No. FLIR20850 Disclaimer: Images for illustrative purposes only.
Specifications subject to change without notice.
General Industrial
www.techrentals.com.au
Temperature Meters/IR Thermometers cont’d.
Infrared Thermal Imaging Cameras cont’d.
Fluke 576 Photographic Temperature Infrared Thermometer
with Built in Camera
FLI,E60-II (4549) AU/MY
Range -30 to 900ºC. Minimum measurement 19mmØ,
laser class II, 3 point spot. Includes adjustable emissivity
from 0.1 to 1 by 0.01. Target size 1/60 of distance.
Max, min, diff and av displayed on backlit lcd with bar
graph. Data output USB or 1mV/ºC, Windows software
and cable included. Accuracy ±0.75% of reading or
±1ºC whichever is greater. Response time 250ms.
Display resolution 0.1ºC. Continuous measure mode.
Digital camera and flash built in.
-20°C to 650˚C, IR and MSX resolution 320 x 240,
60Hz. NETD 50 mK. 2 and 4x digital zoom. Visual
image 3.1mpix, built in LED lamps, laser locator,
scalable IR picture in picture. Video recording, touch
screen, composite video out, Wi-Fi, and USB. Infrared
camera applications include electrical distribution,
mechanical (belts, rollers, couplings, gaskets/seals,
compressors etc), product development, HVAC/R, automotive.
Bluetooth support for voice annotations and selected Extech
equipment. PC software provided. Mobile app available.
Fluke 1523 NATA Precision Handheld Thermometer
Flir E60 Infrared Thermal Image Camera
FLU,576 (4519) AU/MY
Flir E60 MK-II Infrared Thermal Image Camera
FLU,1523-NATA (4514) AU
FLI,E60 MY
Precision, portable, electronic thermometer with
trending and 25 memory positions for NATA-traceable
calibration and high accuracy. Includes 5616 probe
298mm x 6.35mm 100Ω platinum resistance
thermometer probe (PRT) -200 to 420°C, stability
±10mK, accuracy ±0.012°C at -200°C, ±0.011°C
at 0°C, ±0.028°C at 420°C.
-20°C to 650˚C, IR resolution 320 x 240,
60Hz, visual image 3mpix, built in LED lamps,
laser locator, scalable picture in picture. Video
recording, touch screen, composite video out,
Wi-Fi, and USB. Infrared camera applications
include electrical distribution, mechanical (belts,
rollers, couplings, gaskets/seals, compressors
etc), product development, HVAC/R, automotive.
Bluetooth support for voice annotations and selected
Extech equipment. PC software provided. Mobile app available.
Testo 845 IR Thermometer with Humidity Probe and T/C Probe
TES,845 (4527) AU
Temperature measurement -35 to 950°C. Relative
humidity probe 0 to 100%RH. Fast-action surface
probe with sprung thermocouple strip, also for uneven
surfaces. Switchable optical resolution: far field: 75:1
(16mm at a distance of 1200mm). Close focus: 1mm
at a distance of 70mm. Adjustable emissivity from 0.1
to 1, max, min, displayed on backlit LCD. Continuous
measure mode. Data output software and cable
included. Accuracy ±0.75% of reading 100 to 950°C.
Display resolution 0.1°C.
Flir T390 Infrared Thermal Image Camera
FLI,T390 (4556) AU
Infrared thermal imaging camera. -20°C to
1,200°C. MPEG 4 video recording and composite
out, is suitable for almost any application such
as electrical surveys, building diagnostics and
mechanical inspections. With a 3.5 inch touch
screen, Fusion functionality, auto and manual focus, target
illuminator, laser locator and voice text annotation. 50Hz refresh
rate, IR Resolution 320 x 240, visible light camera 3.1 MP.
TR VMS
Australia’s Leading Calibration Laboratory. Established 1989
TR VMS has calibrated and/or repaired equipment from over 2,400
manufacturers - impressive by any measure. All our laboratories,
including our Mobile Calibration Laboratory are NATA accredited and
ISO certified. Your calibration can be provided with, and NATA reporting
and specification.
To minimise downtime, TR VMS provide a Booking Service to assist
you in effectively and efficiently managing your equipment utilisation.
Just call your nearest TR VMS office and arrange a date for the next
available time slot. A quote will be provided stating that the equipment
is to arrive at the TR VMS office the day before the work is due to be
done. Simply sign the acceptance of the quote and return.
You have the choice of a Hypercal Calibration Service, for when the
calibration is urgent, and your job will be “next on the bench” and in
most cases with a one day turnaround. There is a surcharge for this
service. Otherwise utilise the Standard Calibration Service with up to
10 business days for calibration.
39
General Industrial
www.techrentals.com.au
Infrared Thermal Imaging Cameras cont’d.
Infrared Thermal Imaging Cameras cont’d.
Fluke Ti25 Infrared Thermal Image Camera
Fluke Ti32 Infrared Thermal Image Camera
Temperature range -20 to 350°C, accuracy
+/-2°C or 2% (whichever is greater).
Manual focus. SD memory card (2GB
memory card will store at least 1200 fully
radiometric (.is2) IR and linked visual images
each with 60s voice annotations or 3,000
basic (.bmp) IR images). Infrared camera export file formats
JPEG, BMP, GIF, P, TIFF, WMF, EXIF, and EMF. IP54 rating.
20 to 600°C, resolution 320x240. Infrared camera
applications include inside and outside electrical
distribution, motors, pumps, generators, mechanical
(belts, rollers, couplings, gaskets/seals, compressors
etc). Process industry tanks/vessels, pipes, valves,
traps, reactors, and process insulation, HVAC/R.
FLU,TI25 (4567) AU/MY
FLU,TI32 MY
Fluke Ti32 Infrared Thermal Image Camera
FLU,TI32_WIDE-ANGLE MY
Fluke Ti125 Infrared Thermal Image Camera
FLU,TI125 (4566) AU
Temperature range -20 to 350°C, resolution
160 x 120, 9Hz refresh. Video recording up
to 5 mins, video USB streaming, electronic
compass, voice annotation, laser pointer and
torch. Auto focus for distances greater than
1.2m, manual focus for shorter distances.
Accuracy +/-2°C or 2%, NETD 100 mK.
Field swappable, wide angle thermal lens allows the user to have
a wider field of view for working in tight spaces, small rooms, etc.
Field-of-View (FOV) is 46° x 34°. For use with the Ti32 and TiR32.
Fluke Ti32 Infrared Thermal Image Camera with Telephoto Lens
FLU,TI32 TELEPHOTO (4560) AU
-20 to 600°C, resolution 320x240. Applications
include inside and outside electrical distribution and
transmission infrastructure, motors, pumps, generators,
mechanical (belts, rollers, couplings, gaskets/seals,
compressors etc). Process industry; tanks/vessels, pipes,
valves, traps, reactors, HVAC/R. Includes detachable
telephoto lens, field-of-View (FOV) 11.5° x 8.7°.
ShareLive™
video call
Learn More
www.fluke.com/au/connect
TrendIt™
graphs
™
AutoRecord™ EquipmentLog Fluke Cloud™
storage
history
measurements
General Industrial
www.techrentals.com.au
Endoscopes, Borescopes & Visual Inspection
Tachometers/Stroboscopes
See also Pipeline & Cavity Inspection on page 62
Hioki 3404 Optical/Contact Tachometer
Fibrescope MTFS15-1000 1.5mm x 1m Endoscope
FIB,MTFS15-1000 (5168) AU
Working length 1,000mm x 1.5mmØ. Includes light source.
Operating temperature -20 to 60ºC at atmospheric pressure.
Moritex PalmScope Video Capture Device for JPEG
& Movie Clip Recorder Inspection
MOR,PALMSCOPE (5186) AU
Digital Video Recorder, image capture and
storage. Used in conjunction with an endoscope,
borescope or videoscope the PalmScope is
an alternative to a VCR for onsite inspection applications. Unit
records, store video sequences and full frame resolution jpeg
images on supplied 512Mb Compact Flash Card. View images
on built in 6.4” TFT LCD screen. Stores jpeg still images and or
mjpeg movie clips. Signal input video NTSC or PAL, auto-selecting.
Olympus IPLEX-LT 7.5 Portable Industrial Videoscope
OLY,IPLEX-LT 7.5 (5168) AU/MY
Battery powered videoscope. 7.5
meter insertion tube, 6mm diameter.
4 way, 120° articulation. Applications
include inspection of heat exchangers, turbines, gearboxes,
automotive parts and aircraft. Still and video recording to
USB flash, approx 3,400 images and 30 mins per 1 GB.
Olympus IPLEX LT 3.5m Portable Industrial Videoscope
OLY,IPLEX-LT 3.5 (5198) AU
Lightweight, 2.7kg out of transit case.
8.5mm diameter, 3.5m length tungsten
insertion tube. 4 way, 140° articulation.
Still and movie recording to USB flash.
IP55 compliant. Applications include inspection of, heat
exchangers, turbines, gearboxes, automotive parts and aircraft.
Olympus IPLEX- MX II Portable Industrial Videoscope
OLY,IPLEX-MXII (5179) AU
Battery powered industrial vidoscope,
lightweight, just 2.5kg out of transit case.
6mmØ, 3m length tungsten insertion
tube, articulation 4 way UP/DOWN/LEFT/
RIGHT 120º. Field of view 120º, depth of field 18 to 1000mm,
illumination method LED. Brightness adjustment and digital
zoom, built in 6.5” TFT colour display, record JPEG images to USB
flash device. RCA composite video output. Battery or AC powered.
RF Systems VJ-ADV Articulating 3.9mm Video Borescope
RFS,VJ-ADV (5184) AU
Video borescope is 3.9mm in diameter and
1.5 meters long with a flexible stainless steel
braided insertion tube with adjustable brightness
and 90 degree 4 way articulation. Images and
video can be captured and saved to a micro SD
card. Applications include turbine inspection,
heat exchangers, gearboxes in automotive or electrical power
generation, chemical, oil and gas vessel inspection.
High Speed Video Inspection Cameras
Olympus High Speed Camera
OLY,ISPEEDLT (5217) AU
High speed video camera including stand and
lighting accessories. 800x600 color resolution
at 1,000fps. Maximum frame rate 2,000fps.
2.24sec recording time color camera. 4 x lens kit
supplied. Maximum shutter speed 5us.
HIO,3404 (5211) MY
Autoranging 4 digit display. Ranges in RPM mode 30 to 99.9,
1,000 to 9,999 & 1,000 to 9,999 x 10. Ranges in RPS mode
0.5 to 99.99, 100 to 999.9 & 1,000 to 1,600. Analogue output
1mV/10RPM or 1mV/100RPM, accuracy 4%. Tripod mounting.
Internal battery or external AC operation. Contact adaptor
included with cone and peripheral ring.
Monarch PLT200-KIT Digital Contact/Non Contact Tacho
MON,PLT200-KIT (5214) AU
Hand held digital contact/non-contact tacho kit.
Ranges optical/non-contact 5 to 200,000 RPM,
contact 0.5 to 20,000 RPM. Display 5 digits, 5
alpha numeric LCD. Non contact operating range
90cm, tripod mounting. Direct contact tips and
contact wheel supplied. Programmable for IPM,
FT/M, YPM, cm/M, m/M, RPM, RPS, RPH and
Totaliser up to 200,000. Output TTL pulse.
Laser Rotational Shaft Alignment
Easy-Laser D525 Shaft Alignment System
EAS,D525 (4944) AU
Mea Shaft Alignment System. Includes 14
programs for all types of rotating machines. 13
programs for geometric applications. ‘EasyTurn’
function. Thermal Growth Compensation.
Fixturlaser Dirigo Laser Bases Shaft Alignment System
FIX,DIRIGO (4940) AU
Measurement resolution to 0.01mm Shaft diameter
range 40 to 150mm using an extension chain 150 to
500mm. Maximum distance between measurement
units 0.85m. Very simple to use and operate as shims
are applied the alignment can be monitored in real time.
20h of operation from alkaline batteries.
Fixturlaser PAT Pulley Alignment System
FIX,PAT (4941) AU
Laser based alignment system for pulley systems. Measurement
accuracy 0.5mm (0.2º). 20hrs of operation on AAA batteries.
Mechanically self centres on pulley, will operate successfully even
on worn pulley systems.
Pruftechnik Rotalign Pro Laser Shaft Alignment Ex
PRU,ROT-PROEX MY
Laser based rotating shaft alignment system.
Maximum separation between emitter and
receiver 10m. Aligns horizontal and vertical
machines, aligns coupled and uncoupled shafts
equally well. Intrinsically safe system.
Pruftechnik Rotalign Ultra Laser Shaft Alignment
PRU,ROT-ULTRA (4945) AU
Laser based rotating shaft alignment system.
Maximum separation between emitter and
receiver 10m. Aligns horizontal and vertical
machines, aligns coupled and uncoupled shafts
equally well. Ultra modern computer design,
backlit colour display, Intel XScale 400MHz CPU, USB for peripheral
devices, PC, printer, also Bluetooth communication. Backlit
keyboard, rechargeable Li-Ion battery pack. Machine train alignment
- 14 machines. Alignment results in 3 quick steps, thermal growth
computation. Rotalign Ultra Reader software included.
Pruftechnik 1500mm Length Tension Chains
PRU,AL12.116 (4946) AU
1500mm length tension chains for PRU,ROT-ULTRA.
41
General Industrial
www.techrentals.com.au
Industrial Process Calibrators
Industrial Process Calibrators cont’d.
Ametek PPCE 700 Bar Pressure Calibrator
Crystal nVision Pressure Calibrator 30 Bar IS NATA
High pressure calibrator with pump 700 bar (10,000 psi). Digital
display with 5 digit resolution. Accuracy over 70 bar ±0.07.
Accuracy below 70 bar ±0.35. Current and voltage measurement
ranges 4 to 20mA, 0 to 50mA & 0 to 30V.
Intrinsically safe pressure calibrator. Displays realtime recorded data graphically on a high res screen
with ability to zoom into specific events. 500,000
data point memory records all data from all
enabled screens from two modules simultaneously.
Fastest logging interval 10 readings/sec.
Configured with MA20 current, voltage and switch test module
and 30 bar pressure module, accuracy to 0.025% of reading.
Includes hand pump and CPF (finger tight to 700 bar) fittings.
AME,PPCE MY
Beamex MC5 Multifunction Calibrator NATA Certified
BEA,MC5 (4731) AU
NATA certified MC5 provides calibration capability
for pressure, temperature, electrical and
frequency signals. HART communication and
CMX light software provided. Calibration results
can be stored or printed. Performs as a field-entry
device (FED) allowing for the recording of noncalibration related maintenance results. Pressure
modules included, -1 to 20 bar and 600 bar (up to 1,000 bar with
optional external transducers). DC voltage & current, frequency,
and pulse measurement. RTD, thermocouple, and resistance
simulation & measurement. Pressure accuracy EXT-600 bar
0.007% FS +0.01% Rdg, INT-20 bar 0.005% FS +0.01% Rdg,
temperature coefficient ±0.001 % Rdg/°C outside 15 to 35°C.
Beamex MC5-IS Multifunction Calibrator NATA Certified
BEA,MC5-IS (4732) AU/MY
NATA certified MC5-IS provides calibration
capability for pressure, temperature, electrical
and frequency signals. HART communication and
CMX light software provided. Calibration results
can be stored or printed. Performs as a FieldEntry Device (FED) allowing for the recording
of non-calibration related maintenance results.
Pressure measurement range, -1 to 20bar and
600bar (up to 1,000bar with optional external transducers).
DC voltage and current, frequency, and pulse measurement.
RTD, thermocouple, and resistance simulation and
measurement. Pressure accuracy EXT-600 bar 0.007% FS
+0.01% Rdg, INT-20 bar 0.005% FS +0.01% Rdg, temperature
coefficient ±0.001 % Rdg/°C outside 15 to 35°C.
CRY,NVISION-30-NATA (4757) AU
Crystal XP2i 1 Bar (15 psi) NATA with Druck PV411 Hand Pump
CRY,XP2I CAL KIT 1 (4735) AU
Range 1 bar (15 psi) pressure gauge and
Druck PV411 hand pump calibration kit. Nata
certified accuracy, ±0.1% of reading between
20 to 100% of full scale, ±0.02% of full scale
between 0 to 20% of full scale. Generation 3
gauges have 32,000 point logging capacity at
intervals down to 125 msec (in PSV mode). Generation 2 gauges
have 6,000 point logging capability at intervals from 1 sec. Logs
actual pressure, average pressure, average pressure with max
and min and on demand. Intrinsic and safety ratings registered
under IECEx, ATEX and DNV standards.
Crystal XP2i 7 Bar (100 psi) NATA with Druck PV411 Hand Pump
CRY,XP2I CAL KIT 7 (4743) AU
Range 7 bar (100 psi) pressure gauge and
Druck PV411 hand pump calibration kit. Nata
certified accuracy, ±0.1% of reading between
20 to 100% of full scale, ±0.02% of full scale
between 0 to 20% of full scale. Generation 3
gauges have 32,000 point logging capacity
at intervals down to 125 msec (in PSV mode). Generation 2
gauges have 6,000 point logging capability at intervals from 1
sec. Logs actual pressure, average pressure, average pressure
with max and min and on demand. Intrinsic and safety
ratings registered under IECEx, ATEX and DNV standards.
Crystal XP2i 345 Bar (5,000 psi) NATA with Druck PV411 Hand Pump
CRY,XP2I CAL KIT 345 (4765) AU
Beamex MC6 Advanced Field Calibrator
BEA,MC6 (4727) AU
NATA certified MC6 provides calibration
capability for pressure, temperature,
electrical and frequency signals. HART
communication and CMX light software
provided. Calibration results can be stored
or printed. Performs as a field-entry device
(FED) allowing for the recording of noncalibration related maintenance results. Pressure modules
included, -1 to 20 bar and 600 bar (up to 1,000 bar with optional
external transducers). DC voltage & current, frequency, and pulse
measurement. RTD, thermocouple, and resistance simulation &
measurement. Colour touch screen. Pressure accuracy EXT-600
bar 0.007% FS +0.01% Rdg, INT-20 bar 0.005% FS +0.01% Rdg,
temperature coefficient ±0.001 % Rdg/°C outside 15 to 35°C.
New items are being added to the inventory
constantly, so if you can’t see what you’re
looking for, please call us on 1800 632 652.
42
Range 345 bar (5K psi) pressure gauge and
Druck PV411 hand pump calibration kit.
Nata certified accuracy, ±0.1% of reading
between 20 to 100% of full scale, + ±0.02%
of full scale between 0 to 20% of full scale.
Generation 3 gauges have 32,000 point
logging capacity at intervals down to 125 msec (in PSV mode).
Generation 2 gauges have 6,000 point logging capability at
intervals from 1 sec. Logs actual pressure, average pressure,
average pressure with max and min and on demand. Intrinsic and
safety ratings registered under IECEx, ATEX and DNV standards.
Crystal XP2i 690 Bar (10,000 psi) NATA
with PV411 Hand Pump
CRY,XP2I CAL KIT 690 (4770) AU
Range 690 bar (10K psi) pressure gauge
and Druck PV411 hand pump calibration kit.
Nata certified accuracy, ±0.1% of reading
between 20 to 100% of full scale, ±0.02%
of full scale between 0 to 20% of full scale.
Generation 3 gauges have 32,000 point
logging capacity at intervals down to 125 msec (in PSV mode).
Generation 2 gauges have 6,000 point logging capability at
intervals from 1 sec. Logs actual pressure, average pressure,
average pressure with max and min and on demand. Intrinsic and
safety ratings registered under IECEx, ATEX and DNV standards.
General Industrial
www.techrentals.com.au
Industrial Process Calibrators cont’d.
Industrial Process Calibrators cont’d.
Druck DPI603 2-NA 2 Bar Pressure Calibrator
Druck DPI615-20-NATA 20 Bar Pressure Calibrator
DRU,DPI603-2-NA MY
0.075% FS accuracy includes pump pressure. Unit will
pump up to 20 bar pressure. Measurements can be
made to 2 bar positive pressure. The unit has a 24V
energising voltage. Monitors loop current to 55mA DC
loop voltage to 50V. Sealed to IP65. Rechargeable battery operated.
Unit can display in 24 different units. BSP 1/8 interface.
Druck DPI603 20 Bar Pressure Calibrator
DRU,DPI603-20 MY
Accuracy 0.075%FS. Pumps up to 20 bar pressure & -850mbar
vacuum. Measures up to 20 Bar pressure and -1 bar vacuum.
In-built 24V energising voltage. Monitors loop current to 55mA.
Loop voltage to 50V. Interface 1/8” bsp. Battery operated.
Druck DPI104 350 Bar Pressure Calibrator & HTP1 Hydraulic Pump
DRU,DPI104-350 MY
Range 0 to 350 bar. Measures 0 to 100mV (1µV resolution), 0
to 5V (0.1mV resolution), 0 to 50V (1mV resolution) & current 0
to 50mA (1µA resolution) all @ 0.025% accuracy. Sources 0 to
10V (0.2mV resolution) & 0 to 50mA (1µA resolution) @ 0.025%
accuracy. Voltage output regulated 10V ±0.1% current 30mA &
unregulated supply 24V ±10% current 50mA. Pressure switch
status. Pressure media oil, water & non corrosive gases. Battery
operation 10h or mains operation via charger. Complete with a
full range of pressure connection adaptors.
Druck DPI610-2-NATA 2 Bar Pressure Calibrator
DRU,DPI610-2-NATA (4737) AU
DRU,DPI610-2 MY
Pneumatic pressure calibrator including pump and
current voltage standard. Pressure range -1 to 2
bar, ±0.025%FS. Voltage input ±50VDC, ±0.05%rdg,
±0.004%FS. Current input ±55mA, ±0.05%rdg,
±0.004%FS. Temperature -10~40°C, ±1 (ambient) switch open/
closed. Voltage output 10VDC, ±0.1% or 24V ±5%. Current output
0 to 24mA ±0.05% rdg ±0.01%FS. Data logger stores up to
10,000 values. mA ramp configurable. Pressure port G 1/8” (f),
includes flexible hose kit. Pump includes screw adjustment.
Druck DPI610 20 Bar Pressure Calibrator
DRU,DPI610-20 MY
Pneumatic pressure calibrator including pump and current
voltage standard. Pressure range -1~20 bar +/- 0.025% FS.
Voltage input +/- 50 VDC +/-0.05% rdg +/- 0.004% FS. Current
input +/-55mA +/-0.05% rdg +/- 0.004% FS. Temperature
-10~40°C +/-1°C (ambient) switch open/closed. Voltage output
10 VDC +/-0.1% or 24 V +/-5%. Current output 0~24 mA.
Druck DPI610-400-NATA 400 Bar Pressure Calibrator
DRU,DPI610-400-NATA (4768) AU
DRU,DPI610-400 MY
0.075% FS Accuracy includes pump for vacuum and pressure.
Unit will pump up to 2 bar pressure and -850mBar vacuum.
Measurements can be made to 2 bar positive pressure and -1 bar
vacuum. Unit has a 24V energising voltage. Monitors loop current to
55mA DC loop voltage to 50V. Sealed to IP65. Rechargeable battery
operated. Unit can display in 24 different units. BSP 1/8 interface.
Druck DPI 611-20-NATA 20 bar Pressure Calibrator
DRU,DPI611-20-NATA (4748) AU
Fully self-contained pressure test and calibration
system combines pressure generation, signal
measurement and loop power. Generates from
95% vacuum to 20 bar/300 psi pneumatic
pressure with 0.0185% FS accuracy. Calculates
PASS/FAIL errors and documents results. User Guide stored in
the memory of the instrument, 3-touch set-up for any application.
DRU,DPI615-20-NATA (4750) AU
Pneumatic pressure calibrator including pump
and current voltage standard. Pressure range 0
to 20 bar ±0.025% FS. Voltage input ±50VDC
±0.05% rdg ± 0.004% FS. Current input ±55mA
±0.05%rdg ±0.004%FS. Temperature -10 to 40ºC
±1ºC (ambient) switch open/closed. Voltage output
10VDC ±0.1% or 24V ±-5%. Current output 0 to
24mA ±0.05%rdg ±0.01%FS. Data logger stores upto 10,000
values. mA ramp configurable. Pressure port G 1/8 female,
includes flexible hose. Pump includes screw adjustment.
Druck DPI620 GENII 20 Bar Pressure Calibrator
DRU,DPI620-20-NATA (4749) AU
Advanced modular pressure calibrator with
HART, includes pneumatic pressure station with
1/8 BSP(G) or 1/8 NPT test port, -1 to 20 bar
pressure module and an accuracy of ±0.005%
FS. Compact electrical, frequency, temperature calibrator and
HART communicator provides simultaneous measurement and
source capabilities for the setup, testing and calibration of most
types of process instruments including transmitters, transducers,
gauges/indicators, switches, proximity detectors, counters, RTDs,
thermocouples and valve positioners. Accuracy 0.020% FS
(0°C to 50°C), 0.005% FS (at 20°C ±2°C).
Druck DPI 620 Genii Process Calibrator with HART
DRU,GENII (4778) AU
An electrical, frequency and temperature calibrator
with HART communicator. Provides simultaneous
measurement and source capabilities for the setup,
testing and calibration of most types of process
instruments including transmitters, transducers,
gauges/indicators, switches, proximity detectors,
counters, RTDs, thermocouples and valve positioners.
Druck PV411A Multifunction Hand Pump Kit
DRU,PV411A (4789) AU/MY
Provides up to 700 bar hydraulic, 40 bar pneumatic
pressures and vacuum to -950mbar. Built-in stroke
adjuster, lower pressure fine control and tamper proof
overpressure protection.
Druck UPS III-IS Intrinsically Safe Loop Calibrator
DRU,UPS III-IS (4777) AU
Measure or source 0 to 24mA and provide 24V loop
power. 50 VDC measurement and continuity. Accuracy
0.015% of reading, Hart compatible. Dual mA and %
readout, linear or flow. It is an essential tool for loop
testing, instrument maintenance and valve set-up, with
an easy-to-read display and simple-to-use time saving features.
Emerson Process Management 375 Field Communicator
EME,375 MY
Will configure, test, and diagnose your HART® and
Foundation FieldBus devices. Able to communicate
with any device, by any manufacturer. Intrinsically
safe. Easy upgrade over the Internet. Interfaces with
AMS PC Suite Software.
Emerson 475 Hart Communicator
EME,475 (4794) AU/MY
Will configure, test, and diagnose your HART® and
Foundation FieldBus devices. Able to communicate
with any device, by any manufacturer. Intrinsically
safe. Easy upgrade over the Internet. Interfaces
with AMS PC Suite Software.
43
General Industrial
www.techrentals.com.au
Industrial Process Calibrators cont’d.
Industrial Process Calibrators cont’d.
Softing BC-600-PB Profibus Tester 4
Fluke 719 2 Bar-30G Pressure Calibrator including Electric Pump
Allows full testing of live PROFIBUS segments with
minimum influence on their operation. Detects
transient faults that occur sporadically. Test
for non operation PLCs or suspicious devices.
Simultaneous analysis of both bus physics and bus
communication. Master simulator and Topology
scan. Expert tests: frame, oscillogram analysis and
trigger input/output. Long term trend measuring,
preventive maintenance and detailed test reporting.
2 bar, includes pump and precision 4 to 20mA measurement and
source capability. The pump in this instrument is electric.
Uncertainty 0.025%. Precision pressure adjustment vernier.
Range -850mbar to 2 bar. Resolution 0.1mbar. 4 to 20mA
resolution .001mA .015%rdg + 2 counts.
SOF,PROFIBUS-4 (4723) AU
Fitting Set with 700 Bar Hose
FIT,HP MY
Fitting set (max pressure = 10,000 psi) for pressure calibrators.
Female connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP &
NPT; 3/8 inch BSP & NPT; 1/2 inch BSP & NPT.
FLU,719-30G (4740) AU
Fluke Pressure Calibrator 8 Bar includes Electric Pump
FLU,719-100G MY
8 bar, includes pump and precision 4 to 20mA
measurement and source capability. The pump in
this instrument is electric. Uncertainty 0.025%.
Precision pressure adjustment vernier. Range
-850mbar to 8 bar. Resolution 1mBar. 4 to 20mA
resolution 0.001mA 0.015%rdg + 2 counts.
Fluke 725 Process Calibrator
Fitting Set With 20 Bar Hose
FLU,725-NATA (4784) AU
FLU,725 MY
Fitting set (max pressure = 10,000 psi) for pressure calibrators.
Female connector sizes: 1/4 inch BSP & NPT; 1/8 inch BSP &
NPT; 3/8 inc BSP & NPT; 1/2 inch BSP & NPT.
Dual measure/source multifunction process calibrator.
Measure DC 30 V, resistance 3200Ω, 24mA and more.
Source/simulate DC 10V, 24mA, 3200Ω, 12 types
of TCs and 7 types of RTDs. Power transmitters with
internal loop supply. Split display allows view of input
and output values. (Includes NATA calibration - AU).
FIT,LP MY
Fluke 70 Bar Pressure Transducer & Pump suits FLU Calibrator
FLU,700P08-70BAR (4762) AU
Pneumatic system range 0 to 70 bar, resolution 7
mbar, reference uncertainty 0.025%. Connection
1/4 NPT and 1/4 ISO. Includes 700PTP-1
pressure pump (Note the pump will operate to
41 bar). Suitable for use with Fluke Pressure,
Documenting and Process Calibrators such as
the 725, 744, 754 etc.
Fluke 690 Bar Pressure Transducer & Pump
FLU,700P31-690BAR (4771) AU
Range 0 to 690 bar, reference uncertainty
0.025%. Connection 1/4 NPT and 1/4 ISO.
Includes 700HTP-1 pressure pump. Suitable for
use with Fluke Pressure, Documenting and
Process Calibrators such as the 725, 744, 754 etc
Fluke 345mbar Pressure Transducer & Pump
FLU,700PD3-345 MBAR (4734) AU
Dual pressure module, range ±350mbar differential
or gauge, reference uncertainty 0.04%, connection
1/4 NPT. Hand pump included. Suitable for use with
Fluke Pressure, Documenting and Process Calibrators
such as the 725, 744, 754 etc.
Fluke 7 bar Pressure Transducer & Pump
FLU,700PD6-7BAR (4745) AU
Range 1 to 7 bar, reference uncertainty .025%. Connection
1/4NPT and 1/4 ISO Includes 700LTP-1 pressure pump.
Suitable for use with Fluke Pressure, Documenting and Process
Calibrators such as the 725, 744, 754 etc.
Fluke 718 300G Pressure Calibrator
FLU,718-300G (4755) AU
Pressure source and milliamp measurement. Pressure
specs -83 to 2068kPa ±0.05% of range. Max pressure
2.6MPa. Current specs: 0.0001mA resolution, accuracy
0.015%. Calibrate P/I (pressure to current) transmitters,
measures pressure via a 1/8 inch NPT pressure
fitting and an internal pressure sensor, source pressure, measure
current up to 24mA, simultaneously display pressure and current
measurements, supplies loop voltage, calculates percentage in
percent mode, calculates mA error in percent error mode.
44
Fluke 726 Process Calibrator
FLU,726 MY
Precision multifunction process calibrator. DC voltage
measurement. 0.010% 30V max, source 0.010% 20V
max. DC current measurement. 0.010% 24mA max,
source 0.01% 24mA max. Resistance measurement
0.015% 4kΩ max, source 0.01% 4kΩ max. Frequency
measurement 5 counts 1Hz to 15kHz, source 1
count 20Hz to 15kHz. Will measure and simulate 4 to
20mA, TC E N J K T B R S and C, 2, 3 and 4 wire RTDs
and frequency. Loop power supply at: 24V, 22mA. Pulse Source
10k and read 100k. The unit operates from drycell batteries.
Fluke 743 Calibrator
FLU,743B MY
Includes RS232 interface. DC voltage measurement 0.025%,
300V max, source 0.01%, 15V max. DC current measurement
0.025%, 110mA max, source 0.01%, 22mA max. Resistance
measurement 0.05%, 11kΩ max, source 0.01%, 11kΩ max.
Frequency measurement 0.5%, +5, 40 to 500Hz, source 1 count
20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC, source
0.3ºC Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures
and simulates 4 to 20mA, t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4
wire RTDs, frequency, test limit switches. Can use scaling factors
for measurement & source. Built in calculator. Autostep function.
Allows user entered values. Operates as an 8k point data logger.
Note PC software only supports 15 tags.
Fluke 744 Documenting Calibrator with HART
FLU,744 (4782) AU/MY
Documenting process calibrator which includes HART
communication protocols for communicating with and setting up
smart transmitters. RS232 interface. DC voltage measurement
0.025%, 300V max, source 0.01%, 15V max. DC current
measurement 0.025%, 110mA max, source 0.01% 22mA max.
Resistance measurement 0.05%, 11kOhm max, source 0.01%
11kOhm max. Frequency measurement 0.5%, +5, 40~500Hz,
source 1 count 20~5kHz. ‘K’ thermocouple measurement 0.3ºC,
source 0.3ºC Pt100. RTDs measurement 0.3ºC, source 0.1ºC.
Measures and simulates 4~20mA, t/c E, N, J, K, T, B, R, S & C,
2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling
factors for measurement & source. Built in calculator. Autostep
function. Allows user entered values. Operates as an 8k point
data logger. Note PC software only supports 15 tags.
General Industrial
Industrial Process Calibrators cont’d.
Fluke 754 Documenting Process Calibrator with HART
FLU,754 (4781) AU/MY
Offers simultaneous source and measure
capabilities for all common process parameters.
Measure/source volts, mA, RTDs, thermocouples,
frequency, and ohms for the calibration,
maintenance, and troubleshooting of test sensors,
transmitters and other instruments. Compatible
with all Fluke 700Pxx pressure modules. Create
and run automated as-found/as-left procedures to
satisfy quality programs or regulations. Features
include autostep, custom units, user entered
values during test, one-point and two-point switch
testing, square root DP flow testing, programmable
measurement delay etc.
Fluke 773 Milliamp Process Clamp Meter
FLU,773 (4779) AU
Measure 4 to 20mA control lines, PLC loops,
transmitters or any 4 to 20mA line without
breaking the loop. Capable of 0 to 20.99mA
and 24 to 100mA with clamp. Source and
simulate mA and voltage signals in circuit.
4 to 20mA scaled o/p.
www.techrentals.com.au
Industrial Process Calibrators cont’d.
SI PC6 35 Bar NATA Pressure Calibrator & Pump
SI,PC6-35-NATA (4759) AU
Basic accuracy 0.025%. Range is 35 bar. Measures voltage
0~100mV (1µV resolution), 0~5V (0.1mV resolution) & 0~50V
(1mV resolution) & current 0~50mA (1µA resolution) all at
0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA
(1µA resolution) also at 0.025% accuracy. Voltage output
regulated 10V ±0.1% current 30mA and unregulated supply 24V
±10% current 50mA. Pressure switch status. Complete with a full
range of pressure connection adaptors. Record logging capability
444 and RS232 interface download to spread sheet files.
Battery operation 10h or mains operation via charger.
SI PC6 700 Bar NATA Pressure Calibrator & Pump
SI,PC6-700-NATA (4773) AU/MY
Range 0~700 bar. Measures 0~100mV (1μV resolution),
0~5V (0.1mV resolution), 0~50V (1mV resolution) & current
0~50mA (1μA resolution) all @ 0.025% accuracy. Sources
0~10V (0.2mV resolution) & 0~50mA (1μA resolution) @ 0.025%
accuracy. Voltage output regulated 10V +/-0.1% current 30mA
& unregulated supply 24V +/-10% current 50mA. Pressure
switch status. Pressure media oil, water & non corrosive gases.
Battery operation 10h or mains operation via charger.
Wet & Dry Block Calibrators
Fluke 789 Process Meter
Fluke 9141 Dry Block Temperature Calibrator 50 to 650ºC
FLU,789 PROCESSMETER (4786) AU/MY
FLU,9141-NATA (4835) AU
Standard multimeter functions with 2 to 20mA
sink and source capability, including a 24V
supply. HART 250Ω resistor, 20mA drive into
1,200Ω. Simultaneous mA and % of scale
readout on mA output. 25% manual step plus
auto step and auto ramp on mA output. Min/
max/average/hold/relative modes. Double size
dual display. Accuracy, VDC 0.1% +1, VAC 0.7%
+2, mA DC 0.05% +2, frequency 0.005% +1.
Range 50 to 650ºC, basic accuracy 0.5%. Insert hole sizes
1.6mm(1/16”), 3.2mm(1/8”), 4.8mm(3/16”), 6.4mm(1/4”),
9.5mm(3/8”) and 12.7mm(1/2”). Includes PC software and
interface cable. Heating time 1min to 650 deg C. Cooling 25min
from 650 to 100 deg C. Well depth 4.875”. Stabilization time 7min.
Fluke 9144 Dry Block Temperature Calibrator 50 to 660°C
NATA Certification
FLU,9144-NATA (4833) AU
Jofra DPC-500 Documenting Pressure Calibrator 1000 Bar NATA
JOF,DPC-1000-NATA (4775) AU
Documenting pressure calibrator is
used for high precision calibration of
pressure gauges, pressure transmitters,
digital manometers, pressure switches,
overpressure protection valves etc.
Measure pressure at 1,000 bar or 14,500
psi, voltage 0 to 10V, current 0 to 20mA and 4 to 20mA, and
supplies 24VDC as source for transmitters. Accuracy ±0.025% F.S.
Supplied with Druck PV212 1,000 bar hand pump and calibration
software. 15 user selectable engineering units including user
defined. Nata Calibrated.
Field metrology well, NATA certified. Range
50 to 660°C, display accuracy ranges from
± 0.35°C and stability from ±0.03°C. Insert
hole sizes 9.52mm(3/8”) 2x 6.4mm(1/4”),
4.75mm(3/16”) and 3.17mm(1/8”). Well
depth 150mm (5.9”). Includes PC software and
interface cable to 6GHz, 1.5MHz bandwidth,
-45dBm to +20dBm at Normal Mode.
Fluke 9150 Thermocouple Furnace 150 to 1,200°C NATA Certification
FLU,9150-NATA (4840) AU
Temperature range 150 to 1,200°C. Stability ±0.5°C, display
accuracy of ±5°C across entire range. Display resolution 0.1 to
999.9°C, 1° above 1,000°C. Well diameter 32mm, well depth
140mm, insert type 9150 A, 0.4, 6.4, 9.5, 3.2, 12.7mm.
Heating time 35min to 1,200°C, cooling time 140min.
SI PC6 20 Bar NATA Pressure Calibrator & Pump
SI,PC6-20-NATA (4753) AU
Basic accuracy 0.025%. Range output pressure to 20 bar, output
vacuum to -1 b. NATA certified Instrument. Measures voltage
0~100mV (1µV resolution), 0~5V (0.1mV resolution) & 0~50V
(1mV resolution) and current 0~50mA (1µA resolution) all at
0.025% accuracy. Sources 0~10V (0.2mV resolution) & 0~50mA
(1µA resolution) also at 0.025% accuracy. Voltage output
regulated 10V ±0.1% current 30mA and unregulated supply 24V
±10% current 50mA. Pressure switch status. Battery operation
10h or mains operation via charger.
Fluke 9170-R Dry Block Temperature Calibrator -45 to 140°C
FLU,9170-R-NATA (4825) AU
FLU,9170-R MY
Temperature range 150 to 1,200°C. Stability
±0.5°C, display accuracy of ±5°C across entire
range. Display resolution 0.1 to 999.9°C, 1°
above 1,000°C. Well diameter 32mm, well
depth 140mm, insert type 9150 A, 0.4, 6.4, 9.5,
3.2, 12.7mm. Heating time 35min to 1,200°C,
cooling time 140min.
45
General Industrial
www.techrentals.com.au
Wet & Dry Block Calibrators cont’d.
High Speed Waveform Recorders cont’d.
Grant GR150-S5 Temperature Bath NATA Certification
Hioki 8842 16 Analogue, 16 Logic Channel Waveform Recorder
Water/oil bath and circulator for calibrating
temperature probes and analytical procedures.
Temperature ranges from ambient to 100ºC with
water and 150ºC with silicon oil. Requires 3L oil
(not supplied). Stability 0.005ºC, uniformity 0.02ºC
and display resolution 0.1ºC. Tank size 300mm W
x 150mm D x 150mm H. Features include digital
temperature controller and display, pump, timer,
alarms, offset adjustment and more.
Memory 12bits x 16 megawords/ch for 2
analogue ch, to 2 megawords/ch for 16 ch.
Analogue input channel ranges 10mV to 50V
per div, 10X div, 400VDC, 240Vac rms max.
In-built FDD, type III PCMCIA card slot (for
flashcard & HDD up to 520Mb). Sampling
rate of 1MHz max. Functions memory, real time record, RMS, real
time/memory, X-Y memory. Trigger functions level, window in,
window out, voltage drop, RMS level, cycle, logic pattern trigger
1,0 or X (disregard). When using logic channels, logic probes must
be rented separately. Measurement range 400VDC, 240V rms,
low pass filters 5Hz, 500Hz, 5kHz, or 100kHz, input coupling DC,
GND, ac. Large 10.4” colour TFT display for settings and waveform
display, wide thermal printer fitted. On screen help function.
All settings and waveforms can be saved to media, waveforms can
be saved as binary, text or bmp files.
GRA,GR150-S5-NATA (4820) AU
Jofra CTC-650A Temperature Calibrator
JOF,CTC-650A MY
Exceptionally fast and has deep immersion depths
of 110mm (4.3 inch). Heats up to the maximum
temperature in just 20 minutes. Temperature range:
33 to 650°C. Accuracy: 0.9°C. Stability: 0.1°C.
Multi-Hole insertion tube: 1/4”, 1/8”, 3/8” and 3/16”.
HIO,8842 (4150) AU
Hioki 8860 8 Channel High Speed Memory Recorder
HIO,8860 (4129) AU
Jofra CTC-1200A Temperature Calibrator
JOF,CTC-1200A MY
Compact temperature calibrator. Lightweight,
portable for lab and general use. Temperature
range: 572 to 2200ºF (300 to 1205ºC). Excellent
Performance Characteristics. Accuracy: ±4.0ºF
(±2.0ºC). Stability: +1.0ºF (+0.5ºC). Stability Time:
20 minutes. Display in F or C to 0.1 resolution.
Fast cooling and heating. User-selectable Slope Rates for
controlled. Thermo switch testing. Self Diagnostics includes SemiAuto Switch Test and Hysteresis Test. Size of thermowell/insert:
6.5mm & 10mm. 1/4” probe. 1/2” probe.
Strip Chart Recorders
High speed memory recorder, 20MS/s sampling
rate, 8 analogue channels, 16 logic channels,
built in printer. 512MW or direct access
memory, 60GB hard drive built-in, PC card type
II slot up to 4GB ATA flash card (optional) USB,
LAN interface and large colour screen.
Hioki 8938 FFT Input Signal Module
HIO,8938 (4138) AU
FFT Module with anti-aliasing filter. Frequency
range DC to 400kHz, sampling rate 1MS/s.
Maximum input voltage 400VDC, 240V rms.
Hioki 9306 4 Channel Contact & Digital Logic Probe
HIO,9306 (4123) AU
Rototherm C105 10,000 psi Pressure Recorder
ROT,C105 MY
Single pen recording. (±)1% span maximum.
1/2”(M) BSP connection. 255 mm diameter,
circular chart paper.
Rototherm C105 16,000 psi Pressure Recorder
ROT,C105-6K MY
Single pen recording. (±)1% span maximum.
1/2”(M) BSP connection. 255 mm diameter,
circular chart paper.
High Speed Waveform Recorders
Hioki 8841 8 Analogue, 16 Channel Memory Recorder
HIO,8841 (4117) AU
Memory 12bits x 4 megawords/ch for 2
analogue ch, to 1 megawords/ch for 8ch.
In-built FDD, type III PCMCIA card slot (for
flashcard & HDD up to 520Mb). Sampling rate
of 1MHz max. Functions memory, real time
record, RMS, real time/memory, X-Y memory, FFT. Trigger functions
level, window in, window out, voltage drop, RMS level, cycle, logic
pattern trigger 1,0 or X (disregard). When using logic channels,
logic probes must be rented separately. Measurement range
400VDC, 240V rms, low pass filters 5Hz, 500Hz, 5kHz or 100kHz,
input coupling DC, GND, AC. Large 10.4” colour TFT display for
settings and waveform display, wide thermal printer fitted. On
screen help function. All settings and waveforms can be saved to
media, waveforms can be saved as binary, text or bmp files.
46
Contact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842
memory recorders. Threshold digital >1.4V maximum input 50V.
Contact closure input, 2k input resistance 30V allowable input.
Response time 2µs.
Hioki 9320 4 Channel Contact & Digital Logic Probe
HIO,9320 (4140) AU
For HIO, 8811, 8835, 8835-01, 8841 & 8842
memory recorders, 4 channels per probe, max
of 4 probes per recorder. Threshold digital
selectable 1.4V, 2.5V & 4V. Response time
500ns max. Relay dry contact detection.
Max allowable input 50VDC.
Hioki 9335 Wave Processor Software for Hioki 8835,
8835-01, 8841, 8842
HIO,9335 (4155) AU
Waveform Processor software, displays, converts to CSV, calculates
and prints waveforms with a PC. Review stored binary files from
Hioki 8835, 8835-01, 8841 and 8842 memory recorders. Only way
stored binary files can be viewed on a PC without having to re save
them with memory recorder as text files.
Hioki 9725 Memory Viewer Software
HIO,9725 (4157) AU
Data processing software for Hioki 8860 High Speed Memory
Recorder. Functions: file loading, maximum loadable data size 2GW
file saving, measurement of data binary, partial saving between
A/B cursors is possible. Screen images BMP and PNG, calculation
results. Display of saved binary files, displayable channels per
sheet analogue 32, logic 16 channels. Displayable sheets 16.
General Industrial
www.techrentals.com.au
Data Loggers
Data Loggers cont’d.
Datataker CANGATE Gateway & Garmin 5Hz GPS
Hioki 3641-20-Kit Temperature & Humidity Logger
Interface to allow dataTaker loggers and PC
(via RS232) to access CANBUS networks
including J1939 & OBD2. The device also
includes a Garmin 5Hz GPS system.
Temperature and humidity logger includes: 1 x RS232C and
1 x USB communication base, utility software, RS232C and USB
interface cables. Environment conditions for operation -20 to
70ºC, 80%RH (no condensation). Accuracy: temperature -40
to -0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity
typical between ±5 to ±10% depends on temperature and
humidity range. 8000 data points x 2 channels, recording interval
2,5,10,15,20,30s and 1, 2, 5, 10, 15, 20, 30, 60min.
DE,CANGATE (4236) AU
DataTaker DT80 5 to 15 Channel Logger with USB
Memory Stick Download
DE,DT80 MY
Measures voltage, current, resistance and frequency. Up to 15
analogue (±30V) sensor inputs. Each channel is independent
and supports: one isolated 3-wire or 4-wire input, or two isolated
2-wire inputs, or three common referenced 2-wire inputs.
12 flexible digital channels. Expandable to 300 analogue inputs.
Store up to 10 million data points in user defined memory.
DataTaker DT80M 5 to 15 Channel Logger with Built in Modem
DE,DT80M (4234) AU
Includes a built in GSM modem for internet
access to the device supports 2G and 3G
networks (GSM/GPRS/EDGE/WCDMA).
Measures voltage, current, resistance and
frequency. Up to 5 analogue (±30V) sensor
inputs. Each channel is independent and supports: one isolated
3-wire or 4-wire input, or two isolated 2-wire inputs, or three
common referenced 2-wire inputs. Store up to 10 million data
points in user defined memory. Generally used at sample rates
of 1Hz and slower.
DataTaker DT800 Data Logger
HIO,3641-20 MY
Hioki 3641-20-Kit of 8 Temperature & Humidity Loggers
HIO,3641-20-KIT (4256) AU
Kit of 8 x temperature and humidity loggers.
Includes 1 x RS232C and 1 x USB communication
base, utility software, RS232C and USB interface
cables. Environment conditions for operation -20
to 70ºC, 80%RH (no condensation) Accuracy:
Temperature -40 to -0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC,
35.1 to 70ºC ±1ºC. Humidity typical between ±5 to
±10% depends on temperature and humidity range.
8000 data points x 2 channels, recording interval
2,5,10,15,20,30s and 1, 2, 5, 10, 15, 20, 30, 60min.
Hioki LR8431-20 10 Channel Memory Logger
HIO,LR8431-20 (4280) AU
10 Channel Memory Logger with isolated
channel to 60VDC which will take
thermocouples. 10ms sampling USB
interface and USB memory stick. Logging
software included. Log directly to memory
stick. Includes battery for 2.5hrs continuous operation.
DE,DT800 MY
Universal input channels 12 balanced or
42 unbalanced analogue channels. Eight
bi-directional digital channels and 8 digital
input channels. Solid state multiplexer protected to ±40V.
Max in/out voltage ±12V. Serial sensor channel can be used
with GPS systems. Measures V, 4 to 20mA, strain, TC, RTD etc.
Sampling rate 200Hz up to 100kHz in burst mode. Instrument
has RS232, RS422, USB, Ethernet (10baseT) & PC card modem
communications. Pluggable 64Mb memory card stores up to
300,000 (compressed) readings per Mb. Instrument stores
600,000 (compressed) readings in internal memory.
Total memory capacity 10.2Mb (compressed).
Datataker DT85 48 Channel Logger with USB Memory Stick Download
DE,DT85 (4233) AU
Analogue inputs 32 isolated and 48 single
ended inputs. 2 x 4 digital input types. 2 x
serial sensor ports, Modbus capability, 4 x
SDI12 channels, USB memory stick interface
for easy data and programming etc. Operating
time on the internal battery is 1s sample 2.4h.
5s sample 3 days, 1min sample 1 month.
ETM 9900 Intelligent Modem and IO. Sends SMS Messages
ETM,9900 (4290) AU
Can send a user defined alarm message
via SMS. Has 7 IO channels. Will provide
alarm messages for instruments such as
the ARL,NGARA, PRO,VIBRA & the TSI,8520
& 30. Will operate for around 4 months
on 2xD cell batteries when the alarm status
is checked once per hour. Can be put on
site and remotely programmed.
Hioki 8421-01 16 Channel Data Logger with Colour Display
HIO,8421-01 (4270) AU
16 analogue, 4 pulse input channels data logger with colour
display, PCMCIA card slot, LAN interface built in, TCP/IP
communication supports real time PC logging, FTP, SMTP and
HTTP. Signal inputs 100mVDC, 1VDC, 10VDC, 60VDC, 1 to 5VDC
FS. Thermocouples K,E, J, T, N, W (WRe5 to 26) R, S, B, -100 to
100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200 to 800ºC.
Pulse input, accumulation 50,000 counts FS, 500,000 counts
FS, 5M counts FS, 100M counts FS, 2,500M counts FS. Rotation
5,000/n (r/s) FS. Recording interval is selectable from 100, 200,
500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate
is dependent upon type of input signal. Internal Memory 8Mb,
256Mb Flashcard, 9334 logger communicator software, 9642 LAN
cable, 9641 pulse signal input cable all supplied.
Hioki 8421-51 16 Channel Data Logger with Colour Display
HIO,8421-51 (4271) AU
16 analogue, 4 pulse input channels data logger with colour
display, PCMCIA card slot, LAN interface built in, TCP/IP
communication supports real time PC logging, FTP, SMTP and
HTTP. Signal inputs- 100 mVDC, 1VDC, 10 VDC, 60VDC, 1-5VDC FS.
Thermocouples K, E, J, T, N, W (WRe5-26), R, S, B, -100 to 100ºC,
-200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200 to 800ºC. Pulse
input, accumulation 50,000C FS, 500,000C FS, 5MC FS, 100MC
FS, 2,500MC FS. Rotation 5,000/n (r/s) FS. Recording interval
selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s,
1min, 2min, 5min. Max sampling rate is dependent upon type of
input signal. Internal Memory 16MB, 512MB PCMCIA FLASH card,
9334 Logger Communicator software, 9642 LAN cable, 9641 pulse
signal input cable all supplied. Improved common mode rejection
-100dB or better when 50/60Hz, 140dB or better when 50Hz, using
ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling
when using Pt100, improved temperature characteristics.
47
General Industrial
Data Loggers cont’d.
Hioki 8422-51 32 Channel Data Logger
HIO,8422-51 (4273) AU
32 analogue, 4 pulse input channels data logger with
colour display, PCMCIA card slot, LAN interface built in, TCP/
IP communication supports real time PC logging, FTP, SMTP
and HTTP. Signal inputs- 100 mVDC, 1 VDC, 10 VDC, 60 VDC,
1-5V DC FS. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B,
-100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, Pulse input,
accumulation 50,000C FS, 500,000C FS, 5MC FS, 100MC FS,
2,500MC FS. Rotation 5,000/n (r/s) FS. Recording interval is
selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s,
30s, 1min, 2min, 5min. Max sampling rate is dependent upon
type of input signal. Internal Memory 8MB, 512MB PCMCIA
FLASH card, 9334 Logger Communicator software, 9642 LAN
cable, 9641 pulse signal input cable all supplied.
Hioki Kit of Three 9322 Differential Probe High Voltage
True RMS Interface
HIO,9322-KIT (4119) AU
Used with many memory recorders, eg. Hioki 8835. Operating
modes 3. DC mode for waveform monitor output DC to 3MHz, AC
mode detection of power surge noise 1kHz to 10MHz. Rectified
true RMS output of dc & ac voltages. 40Hz to 100kHz response
speed 200ms or less. Max voltage DC 2kV, ac 1kV CATII, AC/DC
600V CATIII, balanced differential input 1/1,000 divider.
Keysight 34980A Multifunction Switch/Measure Unit
www.techrentals.com.au
Pressure Vacuum Gauges/Recorders
Crystal XP2i Digital Logging Pressure Gauge 7 Bar NATA calibrated
CRY,XP2I-100-NATA (4341) AU
Range 7 bar (100 psi) resolution 0.1m bar.
Accuracy is 0.1% of reading, down to 20% of
the range. Vacuum accuracy 0.25% of -1 bar
(-14.5 psi). Generation 3 gauges have 32,000
point logging capacity at intervals down to 125
msec (in PSV mode). Generation 2 gauges have
6,000 point logging capability at intervals from
1 sec. Logs actual pressure, average pressure, average pressure
with max and min and on demand. 1/4 NPT connector. Intrinsic and
safety ratings registered under IECEx, ATEX and DNV standards.
Crystal XP2i Digital Logging Pressure Gauge 20 Bar NATA calibrated
CRY,XP2I-300-NATA (4341) AU
Range 20 bar (300 psi) resolution 0.1m bar.
Accuracy is 0.1% of reading, down to 20%
of the range. Vacuum accuracy 0.25% of -1
bar (-14.5 psi). Generation 3 gauges have
32,000 point logging capacity at intervals
down to 125 msec (in PSV mode). Generation
2 gauges have 6,000 point logging capability
at intervals from 1 sec. Logs actual pressure,
average pressure, average pressure with max
and min and on demand. 1/4 NPT connector. Intrinsic and safety
ratings registered under IECEx, ATEX and DNV standards.
Crystal XP2i Digital Logging Pressure Gauge
70 Bar NATA calibrated
KEY,34980A MY
CRY,XP2I-1K-NATA (4342) AU
34980A multifunction switch/
measure unit is a flexible, reliable
switching and data acquisition
platform. Suitable in design
verification, automated test and
data acquisition. 8-slot mainframe with 21 mix-and-match plug-in
modules. Scans up to 1000 ch/sec. Built-in 6½ digit DMM.LAN,
USB 2.0, and GPIB connectivity, BenchLink data logger software
for easy data collection and analysis. Includes 34934A Quad
4x32 Reed Matrix, 34937A, 32 channel form C/Form A general
purpose switch and 34952A multifunction module with 32-bit
DIO, 2-ch D/A and totalizer.
Range 70 bar (1K psi) resolution 0.1m bar.
Accuracy is 0.1% of reading, down to 20% of the
range. Vacuum accuracy 0.25% of -1 bar (-14.5
psi). Generation 3 gauges have 32,000 point
logging capacity at intervals down to 125 msec
(in PSV mode). Generation 2 gauges have 6,000
point logging capability at intervals from 1 sec.
Logs actual pressure, average pressure, average pressure with max
and min and on demand. 1/4 NPT connector. Intrinsic and safety
ratings registered under IECEx, ATEX and DNV standards.
Testo 175-H1 Temperature & Humidity Logger
TES,175-H1 (4251) AU/MY
Large Display. 3 year battery life, 1 million sample
memory. RH 0~100% +/- 2%, temp -20~50ºC +/0.4ºC. Includes USB interface to download data.
Testo 177-T4 Logger with Display
TES,177-T4 MY
Parameters: temperature (C/F). Sensors: thermocouple type-K.
Number of channels: 4 (external). Measuring range: -100 to
1,000 ºC (external). Memory: 48,000 readings.
See also Air Conditioning & Air Flow on page 58
Watch how-to videos on any piece of
equipment displaying this symbol.
See page 1 for more information
48
Crystal XP2i Digital Logging Pressure Gauge
210 Bar NATA calibrated
CRY,XP2I-3K-NATA (4343) AU
CRY,XP2I-3K MY
Range 200 bar (3K psi) resolution 0.1m bar.
Accuracy is 0.1% of reading, down to 20% of
the range. Vacuum accuracy 0.25% of -1 bar
(-14.5 psi). Generation 3 gauges have 32,000
point logging capacity at intervals down to 125
msec (in PSV mode). Generation 2 gauges have
6,000 point logging capability at intervals from 1 sec. Logs actual
pressure, average pressure, average pressure with max and min
and on demand. 1/4 NPT connector. Intrinsic and safety ratings
registered under IECEx, ATEX and DNV standards.
Crystal XP2i Digital Logging Pressure Gauge
700 Bar NATA calibrated
CRY,XP2I-10K-NATA (4344) AU
CRY,XP2I-10K MY
Range 700 bar (10K psi) resolution 0.1m bar. Accuracy is 0.1%
of reading, down to 20% of the range. Vacuum accuracy 0.25% of
-1 bar (-14.5 psi). Generation 3 gauges have 32,000 point logging
capacity at intervals down to 125 msec (in PSV mode). Generation
2 gauges have 6,000 point logging capability at intervals from 1
sec. Logs actual pressure, average pressure, average pressure with
max and min and on demand. 1/4 NPT connector. Intrinsic and
safety ratings registered under IECEx, ATEX and DNV standards.
General Industrial
www.techrentals.com.au
Flow Meters for Liquids & Gases
Flow Meters for Liquids & Gases cont’d.
See also Environmental Flow Meters on page 69
See Also GLO,FP111 Global FP111 Digital Water Velocity
Meter on page 69
Flexim Ultrasonic Gas Flow Meter
FLE,G608 (6156) AU
Ultrasonic flow meter is a clamp-on transit
time gas and liquid flow meter, 2-channel, with
Zone 2 Ex-certification for use in hazardous
areas. Supplied with three transducer pairs
and a pipe wall thickness gauge; includes an
integral data-logger with more than 100,000
measured values, easy-to-use software for trending the data and
an integral Lithium-ion rechargeable battery with AC adapter.
The GLK transducers are suitable for 4 to 9mm wall thickness,
the GLM 2 to 5mm and the GSM 2.5mm and greater. Utilises
either Shear wave (standard) transducers, or Lamb wave
(specialist gas) transducers. The Lamb wave transducers
resonate the pipe wall to amplify the signal strength, thereby
allowing it to measure applications at significantly lower
pressures than the standard Shear wave transducers.
GE Panametrics PT878GC Ultrasonic
Gas Flow Meter
PAN,PT878GC-01 (6151) AU
Portable non-contact gas flowmeter using transit-time principle.
For operation with ultrasonic transducer-kits (PAN,GC-RL302
& PAN,GC-RL319) - available separately. Compatible with
metal or plastic pipes in the range 20 to 300mm. Suitable
for use with compressed air, natural gas and other gases.
Readout for flow velocity, actual or standard volumetric flow
or mass-flow in numerical or graphic format. Internal logging
for 100K flow data points. Infrared communications port for
download to PC or printer interface. Rechargeable battery for
8h continuous operation.
See page 51 for a case study on the PT878GC
Gas-flow Small Pipe Transducer Kit for PT878GC
PAN,GC-RL302 (6153) AU
Advanced clamp-on ultrasonic transducer pair for use with
Panametrics gas flowmeters. Operation at 1MHz for pipes in
the range 20 to 55mm typical. General purpose use for process
temperatures -40 to 176°C. Supplied with two precision gauged
clamping fixtures for pipe range.
Gas-flow Medium Pipe Transducer Kit for PT878GC
PAN,GC-RL319 (6155) AU
Advanced clamp-on ultrasonic transducer pair for use with
Panametrics gas flowmeters. Operation at 500kHz for pipes in
the range 75-300mm typical. General purpose use for process
temperatures -40 to 176°C. Supplied with set of three precision
gauged clamping fixtures for pipe range.
GE Panametrics PT878 Ultrasonic Flowmeter
PAN,PT878 (6101) AU/MY
Portable non-contact liquid flowmeter using
transit-time principle. Includes transducers
for pipe 50mm to 2mØ & temperatures -40
to 130°C (various alternative transducers
available) with clamping fixture. Flow velocity
range 0.03 to 12.2m/s. Accuracy typically
1%. Data logging for over 100K data points. Analogue inputs
compatible with temperature transmitters for energy-flow
calculations. Outputs analogue 4 to 20mA, digital (pulse or
frequency) and printer/computer (Infrared port). Large LCD
display for velocity, volumetric and energy flow rate, totalised
flow and trend data in alphanumeric and graphical formats.
Rechargeable NiMH batteries and AC power supply/charger.
Panametrics PT878E Ultrasonic Liquid Flow
Energy Meter
PAN,PT878E (6102) AU
Portable non-contact liquid flowmeter using transit-time principle.
Includes transducers to measure energy and transducers for pipe
50mm to 2mØ & temperatures -10 to 130°C (various alternative
transducers available) with clamping fixture. Flow velocity range
0.03 to 12.2m/s. Accuracy typically 1%. Data logging for over
100K data points. Outputs analogue 4 to 20mA, digital (pulse
or frequency) and printer/computer (Infrared port). Large LCD
display for velocity, volumetric and energy flow rate, totalised
flow and trend data in alphanumeric and graphical formats.
Rechargeable NiMH batteries and AC power supply/charger.
GE Panametrics PT878 Ultrasonic
Liquid Flow Meter
PAN,PT878T (6103) AU
Portable non-contact liquid flowmeter using transit-time principle.
Includes thickness gauge and transducers for pipe 50mm to 2mØ
& temperatures -40 to 130 degC (various alternative transducers
available) with clamping fixture. Flow velocity range 0.03 to
12.2m/s. Accuracy typically 1%. Data logging for over 100K data
points. Analog inputs compatible with temperature transmitters
for energy-flow calculations. Outputs analog 4 to 20mA, digital
(pulse or frequency) and printer/computer (Infrared port). Large
LCD display for velocity, volumetric and energy flow rate, totalised
flow and trend data in alphanumeric and graphical formats.
Rechargeable NiMH batteries and AC power supply/charger.
GE Panametrics 12 to 50mm Transducers
PAN,C-LP-40NM (6108) AU/MY
Transducer pair for PAN,PT868/878 transit-time flowmeter to suit
pipe 12 to 50mmØ. Complete with CF-LP-50M mounting bracket.
Temperature range -40 to 120°C.
GE Panametrics -20 to 210°C Transducers
PAN,C-PT-10HB (6110) AU
High temperature transducer pair for PAN,PT868/878 transit-time
flowmeter. Operates on pipe sizes 50mm~2m diameter.
Working temperature range -40~230°C.
GE Panametrics -200 to 400°C Transducers
PAN,OKS (6112) AU
Very high temperature, wide range transducer pair for
PAN,PT868/878 transit-time flowmeter. Temperature range -200
to 400°C, for pipe 80mm to 600mmØ. Uses special clamp system
supplied. Appropriate protection and safe-handling equipment is
required for fitting and operation at very high or low temperatures.
Polysonics Hydra SX30 Dual Frequency Doppler Liquid Flowmeter
POL,HYDRA-SX30-2 (6132) AU
Dual frequency doppler ultrasonic non-contact
flowmeter. Velocity range 0.06 to 10m/s, accuracy
±1%. Pipe size range 12 to 5,000mm diameter.
Data logging for 90,000 points, with PC software
and interface cable for download via RS232C
interface. Transducer temperature range -40
to 122°C. Analogue output 4 to 20mA. Battery
operated, 12h continuous use (8h recharge).
49
GE
Measurement & Control
Unplugged.
Our easy-to-use ADTS500
Series pitot static testers with
innovative wireless technology
and swipe-screen commands
make air data testing simpler,
faster and more accurate.
www.ge-mcs.com
General Industrial
www.techrentals.com.au
Combustion, Flue & Industrial Gas Analysers
Combustion, Flue & Industrial Gas Analysers con’td
See also Environmental Gas & Vapour Meters on page 64-65
Testo 350XL Portable Flue Gas Analyser
Novatech O2 and CO2 Analyser/Transmitter
NOV,1637-5 (5954) AU
Oxygen and carbon dioxide analyser for packaging
atmosphere, general industrial and research use.
Oxygen sensor reading 1ppm to 100% with 1%
accuracy. NDIR carbon dioxide analysis 0 to 100%
±3% of full scale. 2 x 4 to 20mA outputs, 1 common & 3 selectable
alarm relays. Gas connection 1/8 Swagelok. Flow rate with internal
pump 100 to 500cc/min. AC operation.
Testo 335 Combustion Gas Analyser
TES,335 (5913) AU/MY
TES,350XL (5917) AU
Measures O2, CO, CO2 (measured by NDIR),
NO, NO2 and SO2 concentrations plus
draught, temperature, excess air, and gross/
net efficiency values. Ranges: O2 0~25% vol,
CO2 0~50%vol, CO with H2 compensation
0~10,000ppm with measuring-range
extension and selectable dilution factor, NO 0~3,000ppm, NO2
0~500ppm, SO2 0~5,000ppm, draught 50hPa, temperature
-40~1,000°C. Includes switch-off and rinse function for CO
cell and fresh air rinse for longer term measurements. Internal
memory for 250,000 readings, with RS232C interface and
software provided. Operation from mains or rechargeable battery.
Portable industrial flue gas analyser.
Determines temperature (to to 1,000°C),
draught/pressure (±40hPa), oxygen (21%),
carbon monoxide (10,000ppm) and nitric oxide
NO (3,000ppm) concentrations. Calculates
carbon dioxide concentration, efficiency
and flue gas loss. Threshold-protection of sensors, with 5X
autodilution of CO to 50,000ppm. Separate sensor-socket with
mini-probe for ambient temperature, and connection points for
compatible differential-pressure devices. Built-in condensate-trap
with warning and auto-switch-off. Internal memory (100 folders X
10 locations X 200 datasets each) for storage of measurementprotocols and data for printout. Supplied as kit with 335mm
probe, cone and shield-plate, cordless printer and power supply.
Rechargeable or AC operation (alkaline batteries used by printer).
Visit http://www.youtube.com/techrentals for a variety of
useful videos on the Panametrics range and much more!
Gas Flow Troubleshooting
In the Field with the GE Panametrics TransPort PT878GC Ultrasonic Gas Flow Meter
TechRentals rented out a Panametrics PT878GC to a customer
intending to audit compressed air flow at their facility. The set up
involved 50 mm metal pipe with a known pressure of 7 bar.
The customer reported intermittent results and errors when
implementing tests, and requested assistance.
The PT878GC employs the transit-time principle for data collection.
This unobtrusive method of measurement means there is no obstruction
to internal flow, and no need to physically alter pipes to gain access.
TechRentals team member Graeme Murphy went out on-site to inspect
the set-up. The customer appeared to have installed the apparatus
correctly, with proper damping where the transducers were applied to
the pipe, and along the pipe itself, extending out past where the
bracket was mounted.
Damping with either mats or tape is crucial with ultrasonic signal
testing; particularly with metal piping. An echo like phenomenon
known as pipe signals can create interference and compromise
any return signal readings at the transducers.
Relocated
Apparatus
Extra Damping
Connector causing
interference
Before
After
Graeme further investigated by implementing proper test procedure and viewing the results. Errors were indeed frequent, and only
intermittent performance was attainable. A physical inspection of the unit mounting and pipes then followed, and it was discovered
that when touching a small strip of metal used for spacing of the pipe in question to an adjacent pipe, a steady reading was possible.
This implied that the pipe was not properly deadened although the damping appeared to be more than sufficient.
It was determined that the connector would be damped and the entire apparatus would be mounted
further away from the connector. Running the test protocol with the new set up yielded steady, error free
results, and the customer was able to successfully audit the compressed air flow in the pipe.
Read the
full article
51
Physical Measurement
Material Hardness Testers
Non-Destructive Testing
Position Transducers
Inclinometers
Force Gauges
Load Cells
Vibration Analysis
Speed Measurement
www.techrentals.com.au
Non-Destructive Testing cont’d.
Defelsko Positest Pull Off Adhesion Tester for Concrete & Metal
DEF,POSITEST (4895) AU
Measures the force required to pull a specified test diameter
of coating away from its substrate using hydraulic pressure.
Pressure is displayed in both MPa and PSI on a precision dial
indicator and can be related to the strength of adhesion to the
substrate. Suitable for coatings on both metal and concrete
surfaces. Conforms with standards ASTM D4541 and ISO 4624.
Det-tronics W8066 Ultraviolet Test Lamp
DET,W8066 (4860) AU
Material Hardness Testers
GE DynaMic Rebound Hardness Tester
GE,DYNAMIC (4936) AU
Rebound hardness tester tests to ASTM A956 and
DIN 50156. Will compensate for changes in testing
direction. Provides readings in HV, HB, HRC, HRB,
HS, HL & M/mm2.
Krautkramer DynaPocket Rebound Hardness Tester
KRA,DYNAPOCKET (4932) AU
Based on the Leeb’s method HL,
utilising a 3mm tungsten carbide
ball. Other hardness scales can be
selected, HS Shore, HB Brinell, HRB
Rockwell B, HRC Rockwell C, HV Vickers and N/mm2 tensile
strength. Choice of 9 material groups can be selected, they are
St Low-alloy/unalloyed steel and cast steel, ASt Tool steel, SSt
Corrosion resistant steel, GCI Gray cast iron, NCI Nodular graphite
cast iron, AL Aluminium cast alloys, brS Brass, brZ Bronze, Cu
Wrought copper alloys.
Portable, battery operated source of UV radiation.
Used to test UV flame detection systems. A fire
is simulated by the intrinsically safe device by
producing a beam of UV radiation. This beam
has the same wavelength as the response
range of Det-tronics UV Detectors. Enables the operator to
verify the proper system operation without the need for an
open flame. Comparable with a common flashlight, making
it easier to handle and operate than other test lamps.
Olympus Epoch 600 Flaw Detector
OLY,EPOCH600 (4900) AU
General purpose ultasonic flaw detector.
Includes UT angle beam transducers 45,
60 & 70º, and Atlas dual element transducer.
Stores images and data to micro SD card.
Olympus Ultrasonic Thickness Gauge
OLY,27MG (4910) AU
Range 1~500mm, fast min mode. Resolution
0.01mm. Probe operates -20~150 DegC.
Olympus 26mg Pocket Thickness Gauge
PAN,26MG MY
Non-Destructive Testing
Range 1 to 500mm, fast min mode. Resolution 0.01mm.
Probe operates -20 to 150ºC.
Defelsko 6000 Ferrous & Non Ferrous Coating Thickness Tester
Olympus Ultrasonic Thickness Gauge
DEF,POS-6000 (4870) AU/MY
Ferrous/Non Ferrous metal coating thickness tester
with storage of up to 100,000 readings. Supplied
with external probe, calibration standards and
carry pouch. Measurement range 0 to 1500µm or
0 to 60 mils (selectable). Tolerance ±1µm +1% of
reading 0-50µm, ±2µm +1% greater than 50um.
Resolution 0.1µm. Backglow display, HiLo limits
audible & visible alerts when measurements
exceed specified limits. Continually displays
updates average, standard deviation, min/max thickness and
number of readings while measuring. Built in USB, Bluetooth and
Wifi for downloading readings.
PosiTector 200 B & C Ultrasonic Coating Thickness Gauge
OLY,38DL (4905) AU
Operates with dual and single element
transducers, has colour transflective VGA screen.
Includes datalogging capability. Does echo to
echo measurements. Supplied with transducers
to measure steel, cast, corroded steel, rubber,
fibreglass and composites. Includes D7906-SM, M1036,
M2008 M109-RM (inc delay line M202-RM) transducers.
Olympus Ultrasonic Probe for OLY,38DL & OLY,27MG
OLY,D790-SM (4909) AU
Ultrasonic high temperature probe for OLY,27MG
and OLY,38DL 5MHz 7.9mm tip diameter.
Operating temperature range -20ºC~500ºC.
DEF,POS-200ADV (4880) AU
PCWI 30kVDC Porosity (Holiday) Detector
Ultrasonic coating thickness gauge with type B
& C Probes. Measures coating thickness over
wood, concrete, plastics, composites etc. Will
measure up to 3 individual layer thickness in
a multi-layer system and features a graphic
readout. Supplied with both B, 13 to 1000µm for
wood, plastic and composites and C probes 50
to 3800µm for coatings on concrete, fibreglass
etc. Accuracy is ±2µm +3% of reading.
DC Porosity (Holiday) detector. Detects pinholes in coatings
above 150μm on metal substrates such as pipes and tanks.
0-30kV, 3.5 digit LCD display with battery indicator, display
of voltage level. Alarm indicated on front panel, supplied
with rechargeable battery, 10h charger, probe handle with
neon and 2m length cable, 60mm connector for flat brushes,
7m earth cable with clamp, fan brush, 250mm flat brass
wire brush, 450mm probe extension. Dry conditions.
52
PCW,DC30 (4885) AU
Olympus
ultrasound | phased array | eddy current | eddy current array | remote visual inspection | X-ray fluorescence
Olympus designs, manufactures, and globally markets a range of innovative nondestructive
testing and remote visual inspection instruments developed with a commitment to technology,
design, and user friendliness.
These products are used for inspection and maintenance in industrial and research fields
ranging from aerospace and energy to transportation and manufacturing. Olympus instruments
contribute to product quality and add to the safety of infrastructure and facilities. Olympus has
earned industry-wide reputations for providing cost-effective solutions and
excellent support and
customer service.
Technologies
Solutions
Corrosion Testing
Weld Inspection
Security
Flaw Detection
Thickness Measurements
Ultrasound
Ultrasound Phased Array
Eddy Current
Eddy Current Array
Remote Visual Inspection
High-Speed Video
Automated Testing
Image Capture
X-Ray Fluorescence
Tel.: 1300 132 992 • Fax: (03) 9540 0924 • info@olympus.com.au
For worldwide representation visit www.olympus-ims.com
Physical Measurement
www.techrentals.com.au
Non-Destructive Testing cont’d.
Force Gauges cont’d.
PCWI 40kV Pulse Porosity (Holiday) Detector
Hilti Safety Bolt Inspection System
PCW,P40-PULSE (4890) AU
HIL,TESTER4 (4460) AU
Pulse porosity (Holiday) detector. Detects pinholes
in coatings and wrapping above 150µm on metal
substrates such as pipes and tanks. Can be used
on dry or wet surfaces. 0~40kV output, 4 digit LED
display of voltage, alarm sensitivity setting between dry and wet.
Supplied with rechargeable battery, 10h charger, red probe handle
and 2m length of rubber coated cable, 60mm connector for flat
brushes, 7m earth cable with clamp, fan brush, 250mm flat brass
wire brush, 450mm probe extension and 80mm probe extension.
Inspection system to test safety bolts (Safe Ring
Bolts) on the exterior of buildings. The
instrument will check the bolts to AS1891.4-2000
Industrial fall arrest systems and devices. Part 4: Selection,
Use & Maintenance or to AS4488.2-1997 Industrial rope access
systems Part 2: Selection, Use & Maintenance. These tests
need to be performed on a yearly basis on exterior connection
points on building. These safe ring connection points will typically
be used to suspend window cleaning harness systems.
Phynix Surfix FN Ferrous/Non Ferrous Coating Thickness Tester
Mecmesin AFG-1000NALC Digital Force Gauge
PHY,SURFIX FN (4875) AU
MEC,AFG-1000NALC (4428) AU
Thickness tester with memory and statistics. Supplied with
external probe, calibration standards and carry pouch.
Measurement range 0 to 1,500µm or 0 to 60mils (selectable),
tolerance ±1µm +3% of reading, resolution 0.1µm. Display
back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min
substrate thickness type F 0.5mm, type N 50µm. Calibration
factory, zero, foil. Data memory 80 readings max. Interface
infra-red download data to PC utilising hyper terminal.
Range 0 to 1,000N accuracy 0.1%. 5 digit back lit display.
Peak data sampling rate 5kHz. 120% overload warning,
display invert (reverse) function, dual max, max tension & max
compression plus current reading. Outputs: analogue, RS232
& Mitutoyo. Accessories: test hook, compression plate, 130mm
& 30mm extension rods, rotary coupling. Mounting tapped holes
x 2, M5 x 0.8 x 5.5mm deep max. Optional smart sensors can be
used, such as TW60 static torque wrench.
Position Transducers
Load Cells
MEL M5-200 4 to 20mA Optical Position Transducer
AIC Controller with 7T S Type Load Cell NATA Calibrated
MEL,M5-200 (5315) AU
AIC,S-7T-NATA (4404) AU
Optical distance measurement device 4 to 20mA
output. Will measure distance from 240mm to
440mm with an accuracy of 0.06mm. Does not
require a reflector on the surface of the device.
Light spot diameter is 10mm. Light sensor is IP67. 4 to 20mA
transmitter is IP40. Will operate from 10 to 30V. Relay outputs
indicate error condition. 1ms, 2ms or 20ms adjustable reaction
time. Light source infrared 890nm invisible.
AIC Controller with a 7,000kg loadcell. The controller has an
RS232 output for recording. The unit has a rechargable battery.
Inclinometers
Gloi ALiSensor Level and Flatness System
Dillon ED2000 5,000kg Crane Scale
DIL,ED2000-5K (4452) AU
Complete with shackles. Range 5,000kg.
Accuracy 0.1%.Resolution 1kg. i.e. 20kg uncertainty.
Units of measure: kg, kt, mt, & lb. Proof load 200%
of rated load. Displays gross and net force.
Continuous measurement and peak hold.
GLO,ALISENSOR (5325) AU
Precision level system including an iPad with
applications for Straighness, Squareness,
Flatness, Spindle Parallelism, Spindal
Perpendicularity, Shaft Level and Shaft Plumb.
Angle can be measured to 0.001Deg and flatness can be
determined to 0.0025mm. Includes a magnetic fixture.
Dillon EDX 20T NATA Crane Scale with Wireless Remote
DIL,EDX-20T-NATA (4450) AU
Digital crane scale. NATA calibrated 20T capacity,
includes shackles and remote radio display/controller.
Accuracy ±0.1%FS. Has peak hold. Will measure in
kgF ibF or Newton.
Wyler Clinitronic 45 Inclinometer RS-232C
WYL,CL45 (5326) AU
Resolution 0.01º. Accuracy better than 30arc sec. Display
inclination in all common measurements. Includes RS232
interface for remote display of inclination and also logging.
Settling time <5s.
Force Gauges
Hiliti Fastener Test System includes SafeRIngs Systems
HIL,HAT28M (4465) AU
A purpose-made system for testing fastenings.
It consists of a mechanical screw arrangement
acting through a hydraulic load cell which
measures the load applied to the fastener directly.
54
Futek IHH500 Pancake Load Cell 2T Capacity
FUT,IHH500-2T (4416) AU
TheIHH500 display & LCF500-FSH02968
loadcell operate at up to 20 tonnes (50,000lb)
in compression and tension. The IHH500
handheld display is a logging microcontroller
which can store up to 21000 points, it is
powered by a rechargeable battery which can
last for up to 30 hours depending on battery condition and load.
It will operate from its mains charger if needed. The system has
a simple ‘Tare’ function and can display ‘Max Hold’ using a single
front panel key. The lead that connects the loadcell to the display
is 1.6 Meters long. The load is connected via M33x2-Threads.
There are two eye bolts supplied with the system, however the
eye bolt capacity is 7 ton. The software is supplied on a USB
flash drive/dongle.
Physical Measurement
Load Cells cont’d.
www.techrentals.com.au
Vibration Analysis cont’d.
Futek IHH500 Pancake Load Cell 20T Capacity
Rion VA-10 Vibration Analyser
FUT,IHH500-20T (4418) AU
RIO,VA-10 MY
IH500 display and LCF500-FSH02968 load cell
operate at up to 20 tonnes (50,000lb) in compression
and tension. The IHH500 hand held display is a
logging microcontroller which can store up to 21,000
points, it is powered by a rechargeable battery which
can last for up to 30 hours depending on battery condition and
load. It will operate from its mains charger if needed. Has a
simple ‘Tare’ function and can display ‘Max Hold’ using a single
front panel key. The lead that connects the loadcell to the display
is 1.6 Meters long. The load is connected via M33x2-Threads.
Software is supplied on a USB flash drive/dongle.
Vibration Analysis
See also Noise & Sound Analysers on page 66-67
Fluke 810 Vibration Tester
Measures acceleration, velocity and displacement. Stores 500
readings. LCD display with waveform, spectrum and data readout.
Auto measurement function. Includes printer interface.
Rion VA-11 Vibration Analyser
RIO,VA-11 MY
Includes 2 pickup types hand held (PV55) and magnetic type
(PV57). Measures acceleration, velocity and displacement.
Displays RMS, peak and crest factor. Uses FFT to display
power and vibration spectrum. Incorporates PCMCIA card
flash memory for data storage. RS-232 interface available.
PV57 1Hz to 5kHz, PV55 3Hz to 20kHz (velocity 3kHz,
displacement 500Hz). Acceleration 0.02 to 316mm/s2 rms.
Velocity 0.1 to 1,000mm/s rms. Displacement 0.003 to
28.3 (EQ PP). High pass filter 3Hz, 10Hz & 1kHz. Low pass
1kHz, 5kHz and 20 kHz. Stores 500 measurements.
FLU,810 (5050) AU/MY
Tests rotating machinery to determine the
status of gearing wear etc. Used to: Troubleshoot
equipment and understand cause of failure.
Commission new equipment and ensure proper
installation. Includes triaxial accelerometer and
laser tacho. Store and reports FFT images to your PC. Very simple
output that reports Pass and Fail on machinery condition.
GTI Spindle Vibration Analyzer and Balancing System
GTI,IPAD3VAB (5040) AU
This system is based around an iPad. Measurement
range ±196m/s2, frequency range 1.6 to 10kHz.
Includes accelerometer on a 3m lead with a
magnetic base and an optical position sensor.
Measures Acceleration or Velocity giving a 0~20kHz FFT display.
Madgetech Shock 101-EB TR-Axial Transportation Logger
MAD,SHOCK101 (5026) AU
Battery powered, stand alone 3-axis shock recorder, extended
battery life of up to 60 days typical. Measures and records
shock as the peak acceleration levels over the user defined
interval. Designed for documenting dynamic environments
such as moving vehicles, containers, ships, etc.
Rion VA-12 Vibration Analyser
RIO,VA-12 (5040) AU
Includes magnetic pickup type. Will store
measurements. Measures acceleration,
velocity and displacement and displays it
in either time or frequency domain. It will
display rms, peak and crest factor. Uses FFT
to display power and vibration spectrum.
Incorporates SD card memory storage.
Svantek SV100 Whole Body Vibration Analysis
SVA,SV100 (5005) AU
Completely self-contained, integrated unit.
Does whole body vibration dose (exposure)
measurements, octave measurements,
time domain record measurements and
motion sickness measurements. Includes
external alarm, car power adapter or will run
from battery pack for >16hrs. USB interface
for programming and download.
TMS Portable Vibration Calibrator including Wobulator Option
Profound Vibra Ground Vibration Logger
PRO,VIBRA (5023) AU/MY
Designed for long term ground vibration logging.
Includes a Geophone and remote alarm with
flashing light. Velocity Range 0 to 100mm/s.
4 weeks operation on 3 x D cell batteries. USB
interface. Download possible while measuring. Full Windows
analysis software included. IP65 case. Meets standards for
‘Vibration in buildings’ - Effects on structures’ and ‘Effects
on persons in buildings.
TMS,9110D-WOB (5080) AU
Portable calibrator will test accelerometers,
velocity transducers and proximity probes. It
can provide 7Hz to 10kHz vibrations. Maximum
amplitude 20g (no load). Maximum payload
800gram. Includes an interface to most common
accelerometers and a report generation capability.
Profound Vibra Plus Ground Vibration Logger
PRO,VIBRA-PLUS (5023) AU
Designed for long term ground vibration logging.
Includes a Geophone and remote alarm with
flashing light. Velocity Range 0~100mm/s. 4 weeks operation on
3xD cell batteries. IP65 case. The Plus model provides dominant
frequency information and includes a Modem so alarm messages
can be emailed and sent via SMS, and a daily report can be emailed.
Learning to operate unfamiliar equipment
costs you time and can lead to errors.
Save time and reduce your real costs.
Find out all about our Configuration
and Download solution on page 37
55
Physical Measurement
www.techrentals.com.au
Vibration Analysis cont’d.
Speed Measurement cont’d.
TR Viblog Vibration and GPS Logger
Vehicle Counts PC2500 2 Channel Vehicle Volume & Speed Counter
TR,VIBLOG (5060) AU
VEH,PC2500 (5320) AU
Incorporates a 3D accelerometer, a 3D gyroscope
and a 10Hz GPS system. Logs 10 measurements
per second. Records these measurements and
also provides a Google Earth plot of the horizontal
vibration and vertical vibration by location.
A histogram of the vibration against velocity is provided also.
The loggers battery lasts around 24hrs. Has sufficient memory to
record 10 samples per second over this time.
An automatic traffic counter used to collect
vehicle traffic data on roadways. It collects
data from one or two road tubes (rubber hose)
stretched across the road. Can be used to collect data for traffic
volume, vehicle classifications, and/or vehicle speeds.
Speed Measurement
Phantom 53550 Radar Gun with Case and Tuning Fork
PHA,53550 (5324) AU
Doppler K band (24.150GHz) stationary radar
gun. Pull the trigger and the speed display
appears instantly. Invisible to all radar detectors.
Power requirements 10.5 to 16.5VDC, 13.5VDC
nominal, 1.5A max, external source, connection via 1.8m coiled
power cord with fused lighter plug. Operating environment -20
to 60ºC, 90%RH @ 37ºC (non-condensing). Accuracy ±0.17kph.
Accuracy verification tuning fork (K-Band), internal 90kph.
Speed range 17 to 332kph.
The TR Viblog Vibration and GPS Logger was the
equipment used in the Vehicle Condition Monitoring
article on the following page. You can watch a how-to
video on the TR Viblog or read the whitepaper Australian
Railways’ Weakest Link via the QR codes below.
Watch
the video
Read the
white paper
Major Projects
Is your major project?
• Telecommunication
• Construction
• Road or Rail infrastructure
• Power Generation
• National Broadband Network
• Port Infrastructure
With over 40 years experience TechRentals technical sales staff will assist you in delivering the right test and measurement
solution for your major project. Whatever the duration, the best solution will be tailored to your requirements, making this
part of your project simple and easy.
With access not only to our vast inventory but to our global partners’ inventory you can be assured we will deliver the
best solution for you.
56
Vehicle Condition Monitoring System
How to reduce track damage and derailment risk
TechRentals has developed a condition monitoring system to measure the lateral and vertical acceleration experienced by
railway vehicles. This enables not only track problems to be identified but also enables the vehicle performance itself to be
evaluated on a comparative basis. The system was developed particularly for railway use however the system has potential
for use in any analogous transport system.
The system is based on a GPS system updated at a 10Hz rate with measurements
provided by a triaxial accelerometer. The physical implementation is quite simple and
all that is required is for the measurement apparatus to be placed in the vehicle for
the duration of the journey. The data is transferred to a memory card with the output
subsequently processed to create a unique output format that utilizes Google Earth data
as a reference. This output format clearly shows track ab-normalities and also allows
the responsible staff to compare the performance of different rail vehicles across the
same section of track. The presentation is such that the concept and operation can be
understood with the briefest of training.
The image in figure 1 shows a significant problem highlighted by the magnitude of the red
and white line deviations. The red is the vertical and the white is the horizontal movement.
The location of the problem is readily identified very accurately using GPS coordinates, etc.
Figure 1
In figure 2 we have a typical log which allows the magnitude of the movements to be
easily determined together with the speed, etc. This shows a vertical acceleration
of between 1.95g and .44g. The horizontal was -.2 to .3g horizontally at a speed of
124.5kph. The log is continuous allowing further analysis.
The instrument will also provide histograms that summarize the horizontal and vertical
vibration performance of the vehicle for different speeds. This enables different vehicles
to be compared across the same piece of track.
The system allows extensive routine measurements to be taken without the use of
specialised measurement vehicles at the actual service speeds using standard vehicles.
There is no disturbance to normal track operation. Apart from passenger service
customer comfort there are savings by minimising track damage and establishing
optimum vehicle speeds.
Figure 2
There is the potential to investigate a relationship between vehicle design or adjustment, freight loads, and speed
with a view to gaining the maximum long term handling capacity from existing track. The cost savings from such an
investigation can be substantial.
Construction
Air Conditioning & Air Flow
Air Conditioner Valve Balancing
Concrete Testing Equipment
Underground Services Location
Utility Leak Detection
Ground Penetrating Radar
Pipeline & Cavity Inspection
Distance Measurement & Surveying
Air Conditioning & Air Flow
Airflow 36 Pitot Tube
AIR,PITOT-36 (5816) AU
Pitot tube (36”) for use with manometers and micro manometers.
Alnor EBT-721-A3 Electronic Micromanometer
ALN,EBT-721-A3 MY
Detachable multi-purpose digital manometer that can be used
with the following test and balance tools, such as pitot, air foil,
temperature, relative humidity probes or a 16-point velocity
matrix. Differential pressure: ±15 in. H2O, (3735 Pa) 150 in.
H2O maximum safe operating pressure. Absolute pressure: 15 to
40 in. Hg (356 to 1016 Hg). Velocity: 25 to 8,000 ft/min (0.125
to 40 m/s) pitot probes; 25 to 5,000 ft/min (0.125 to 25 m/s)
air flow probe; 25 to 2,500 ft/min (0.125 to 12.5 m/s) velocity
matrix. Volume: 25 to 2,500 ft3/m (42 to 4250 m3/h) capture
hood. RH: 0 to 95% RH (optional probe), Temperature: -40 to
250°F (-40 to 121°C) probe dependant. Standard comes
with 2ft x 2ft, upon request additional hood of 2ft x 4ft and
1ft x 4ft hood would be provided.
Alnor EBT731 Balometer Electronic Balancing Tool
ALN,EBT-731 MY
Features a detachable multi-purpose digital
manometer that can be used with the
following test and balance tools, such as
pitot, static pressure probe or a 16-point
velocity matrix. Volume Range: 25 to 2,500
ft cube/min (42 to 4250 m cube/h) with
capture hood. Velocity Range:25 to 2,500 ft/
min (0.125 to 12.5 m/s) with velocity matrix.
Unit comes with 2ft x 2ft,2ft x 4ft and 1ft x 4ft hoods.
CSS Portable Smoke Generating Machine
CSS,COLT4 (5890) AU
Portable smoke generator with variable
smoke emission rate. Suitable for air flow
visualisation, HVAC ductwork leak-testing,
fire training and general work. Pump-free
operation with smoke fluid supplied from
consumable aerosol cans. Manual or continuous operation and
off-power facility. Maximum output 31 cubic meters/min at 1.5m
visibility. Operation for 18min from one can at maximum capacity.
Druck DP1705 Manometer 0 to 20kPa
DRU,DPI705 (5808) AU
Handheld digital manometer range 0 to 20kPa, accuracy 0.2%.
Displays all common engineering units.
58
www.techrentals.com.au
Air Conditioning & Air Flow cont’d.
Druck DPI705-IS Manometer 0 to 20kPa Intrinsically Safe
DRU,DPI705-IS (5809) AU
Hand held Manometer 0 to 20kPa range. Accuracy
0.2%. Displays all common engineering units.
Intrinsically Safe.
Druck DP1705 Pressure gauge 7 Bar ABS
DRU,DPI705-7BARA (5810) AU
Handheld digital pressure gauge range 0~7bar absolute, with remote
sensor, accuracy 0.1%. Displays all common engineering units.
Testo 445 Vane Anemometer with 16mm Vane
TES,445 (5842) AU
Micro-vane probe. Simultaneous digital display of air
velocity and temperature, with continuous-update,
max, min & mean functions. Volume-flow option
with entry of duct dimensions. Telescope mounted
metal probe, vane 16mmØ. Operating range 0.4 to
60m/s, accuracy ±0.2 m/s, ±1%mv up to 40m/s.
Temperature range -30 to 140ºC for short-term measurements.
Selectable site-locations, and 3,000 point internal memory for
manual saving or automatic data logging. Battery powered.
TSI 8324 VelociCalc 100mm Vane Anemometer with Volume Display
TSI,8324 (5839) AU
Vane anemometer with 100mm head, supplied
with handle and 900 mm articulated telescopic
extension. Velocity measurement range 0.25
to 30m/s ±1%; temperature measurement
range 0 to 80ºC ±0.5 ºC. Volume display range
0 to 4.36 x 106m3/h with input for circular or rectangular duct
dimensions. Variable time-constant; sample statistics average,
max and min; and “sweep” mode for extended continuous
sampling. Internal memory for single point measurements or
time-based data logging, for up to 2849 samples and 1,000 test
IDs, with serial interface, cable and software for data download.
Direct data acquisition [polling] from PC terminal modes.
Battery powered with auto-power-off, and optional AC adaptor.
TSI 8373 Balometer With Logging
TSI,8373 (5826) MY
Flow range 15 to 1,000l/s (54 to 3,600m3/h); accuracy ±5% [to
±2.4l/s]. Operating temperature range 0 to 60°C. Includes 5 hood
kit & hard case. Hoods provided 610 x 610mm (standard), 610 x
1,220mm, 305 x 1,220mm, 305 x 1,525mm & 915 x 915mm.
TSI 8375 Accubalance Modular Air Balancing Tool
TSI,8375 (5827) AU
Balometer with detachable micromanometer
(TSI 8710) for air balancing applications.
With 610 x 610mm air capture hood for
measurements in the range 42 to 4250m3/h with
automatic compensation for barometric pressure
and air temperature, 45cm pitot probe [range 0.13
to 41m/s], 16-point velocity matrix probe [0.1313m/s] and static pressure probes [differential pressure range
±3735Pa with safe limit 37kPa, absolute pressure range 47 to
135kPa. Accuracy typically 2% for pressure, 3% for flow. Large,
multi-line backlit LCD display for single or statistical readings with
min, max and average of up to 1,000 values of each measured
parameter. Manual result storage or automatic data logging
up to 1,000 time/date stamped readings. RS232 port for data
transfer to PC or serial printer, with cable and “LogDat” download
software. Rechargeable with approx 12h operation, or AC adaptor.
Construction
Air Conditioning & Air Flow cont’d.
TSI 8380 Balometer and Hood Kits
TSI,8380 (5826) AU
Includes 8715 manometer and logging capability.
Includes 610 x 610, 305 x 1220, 610 x 1220, 305
x 1525 and 915 x 915 hoods.
TSI 8386A VelociCalc Air Conditioning Efficiency Meter
TSI,8386A (5848) MY
Portable efficiency measurement system for HVAC and related
work, with hot wire anemometer, static and differential pressure,
temperature and humidity measurement with heat flow efficiency
calculation. Velocity (hot wire) 0 to 50m/s, accuracy ±3%.
Temperature -10 to 60°C, accuracy ±0.3. Wet bulb temperature 5 to
60°C. Relative humidity 0 to 95%RH, accuracy ±3%. Dewpoint -15
to 49°C. Static/differential pressure -1,245 to 3,735Pa, accuracy
±1%. Probe length 100cm, tip diameter 7mm, base diameter
10mm. Includes data logging and printing. Battery operated.
TSI 8710 DP-CALC Differential Micro-Manometer
TSI,8710 (5813) AU
Micro-manometer for static or differential
pressure, velocity, volumetric flow, atmospheric
pressure and temperature. With statistical
analysis, density correction, K factor and
automatic actual/standard flow calculation. Differential pressure
range ±3735Pa. Velocity display to 41m/s (range depends on
probe). Supplied with static tip, pitot tube, velocity matrix and
temperature probe. Datalogging (1,000 point) with RS232C
interface and software. Rechargeable cells or AC adaptor.
www.techrentals.com.au
Air Conditioning & Air Flow cont’d.
TSI 9565A VelociCalc Air Conditioning Efficiency Meter
TSI,9565A (5849) AU
Portable efficiency measurement system for HVAC
and related work, with hot wire anemometer, static
and differential pressure, temperature and humidity
measurement with heat flow efficiency calculation.
Velocity (hot wire) 0 to 50m/s, accuracy ±3%.
Temperature -10 to 60°C, accuracy ±0.3. Wet bulb
temperature 5 to 60°C. Relative humidity 0~95%RH,
accuracy ±3%. Dewpoint -15 to 49°C. Static/
differential pressure -3,735 to 3,735Pa, accuracy ±1%.
Probe length 1m, tip diameter 7mm, base diameter 10mm.
Includes data logging and printing. Battery operated.
USB & Bluetooth download.
Vaisala WAA151 Wind Speed/Direction Transducer
VAI,WAA151 (5886) AU
Range 0.4 to 75m/s. Current output with selectable ranges
including 4 to 20mA & 0 to 20mA. Requires indicator module such
as DE,DT600 datalogger for indication of wind speed and direction.
Air Conditioner Valve Balancing
See also Data Loggers: Testo Temperature & Humidity
Loggers on page 48
Tour & Anderson Scope Balancing Meter 1000kpa
TA,CBI MY
Includes data captured download software and USB cable. Logs
velocity and temperature. Will calculate flow rates. 0 to 30m/s
Accuracy 3% of reading or ±015m/sec whichever is greater.
Temperature range -18 to 93°C ±0.3°C. Runs 4 x AA batteries.
Digital pressure balancing instrument with LCD display. For
cooling water valve balancing in air conditioning plants and
similar applications. Firmware revision 3A. Includes facility for
entry of Kv value to allow balancing of all hydronic valve types.
Differential pressure range -0.5 to 20.5m water gauge at a total
pressure of less than 200m. Resolution 0.001m. Flow resolution
0.001l/s. Battery operated.
TSI 9555 Multi-Function Ventilation Meter
Tour & Anderson Scope Balancing Meter 1000kpa
TSI,9555 MY
TA,SCOPE (5801) AU
Portable, hand held, multi-function ventilation meter. Comes with
differential pressure and 966 articulate probe which measures
air velocity, temperature and humidity. Calculations include air
flow, heat flow, turbulence, wet bulb and dew point temperature.
Velocity measurement: Range: 0 to 9,999 ft/min (0 to 50 m/s),
Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s), Resolution:
1 ft/min (0.01 m/s). Temperature measurement: Range: 14 to
140°F (-10 to 60°C), Accuracy: ±0.5°F (±0.3°C), Resolution:
0.1°F (0.1°C). Humidity measurement: Range: 0 to 95% RH,
Accuracy: ±3% RH, Resolution: 0.1% RH.
Digital flow balancing instrument with color
display. For cooling water valve balancing
in air conditioning plants and similar
applications. Includes facility for entry of
Kv value to allow balancing of all hydronic
valve types. Differential pressure range -0.5
to 20.5m water gauge at a total pressure of
less than 200m. Resolution 0.001m.
Flow resolution 0.001l/s. Battery operated.
TSI 9535 Anemometer with Logging Capability
TSI,9535 (5845) AU
TSI TA465A Multi-Function Ventilation Meter
TSI,TA465A MY
Portable, hand held, Multi-Function Ventilation
Test Instruments. It comes with differential
pressure. It also comes with the 966 articulate
probe which measures air velocity, temperature
and humidity. Calculations include air flow,
heat flow, turbulence, wet bulb and dew point
temperature. Velocity Measurement Range: 0 to 9,999 ft/min
(0 to 50 m/s) Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s)
Resolution: 1 ft/min (0.01 m/s) Temperature Measurement
Range: 14 to 140°F (-10 to 60°C) Accuracy: ±0.5°F (±0.3°C)
Resolution: 0.1°F (0.1°C) Humidity Measurement Range:
0 to 95% RH Accuracy: ±3% RH Resolution: 0.1% RH.
Concrete Testing Equipment
See also Endoscopes, Borescopes & Visual Inspection on page 41
See also Ground Penetrating Radars on page 61
See also Pipeline & Cavity Inspection on page 62
Elcometer 331-B Basic Cover Meter
ELC,331-B (4924) AU/MY
Displays depth and orientation of the reo bars.
Deep search head supplied. 40mm diameter bar
depth 35 to 180mm depth, 8mm diameter bar
depth 25 to 160mm depth. Rechargeable battery
allows 32h of continuous operation (20h with backlight).
59
Construction
www.techrentals.com.au
Concrete Testing Equipment cont’d.
Concrete Testing Equipment cont’d.
Elcometer 331-SH Cover Meter with Half Cell Measurement
Handy Search NJJ-95B Reinforced Concrete Radar
ELC,331-SH (4919) AU
JRC,NJJ-95B (4923) AU
Displays the depth and orientation of the reo bars. Standard
search head. 40mm diameter bar depth 15 to 95mm. 8mm
diameter bard depth 8 to 70mm. Rechargeable battery allows
32h of continuous operation (20h with backlight). Autosizing of
bars or orthogonal measuring of bar sizes. Internal storage of
readings of depth of cover in batches which can be downloaded
to PC with supplied software. XP and Vista supported.
Ground Penetrating Radar (GPR) technology
applied to the location of reinforcement in
concrete. Unit will search to a depth of 300mm.
Display is very easy to interpret (scanned
images). Scan information can be saved to
a memory card for transfer to a PC. A 3D image of the slab can
be generated using PC software. Can be used to detect voids in
concrete and the concrete depth is easy to determine from the
image. The location of non-metallic objects can also be determined.
Hilti PS200 Ferroscan System
HIL,PS200 FERROSCAN (4920) AU
Proceq 2000-ND Digi Schmidt Test Hammer
Portable, quick and easy to use for detecting
rebar and other ferrous objects in concrete
structures. Provides accurate on-site rebar
location, depth and diameter with the
PS 200M monitor. Scans can be evaluated on the monitor or
transferred to a PC or laptop for further evaluation and report
generation. Portable wireless operation, easy integrated
LCD display makes setting up the scan easy while providing
information over the scan process. Fast data download via
infra red beam from scanner to monitor. Convenient Scanner
stores up to 9 image scans and 30m of Quickscans.
PRO,2000-ND (4930) AU
Hilti PS250 Ferroscan System
HIL,PS250 (4921) AU
Portable, quick and easy to use for detecting
rebar and other ferrous objects in concrete
structures. Provides accurate on-site rebar
location, depth and diameter with the
PSA100 monitor. Scans can be evaluated on the monitor or
transferred to a PC or laptop for further evaluation and report
generation. Portable wireless operation, easy integrated
LCD display makes setting up the scan easy while providing
information over the scan process. Fast data download via
infra red beam from scanner to monitor. Convenient Scanner
stores up to 9 image scans and 30m of Quickscans.
Concrete hardness tester (Schmidt hammer).
Supplied complete with inbuilt graphical LCD
for setting up and graphical display of results,
up to 500 results can be stored. RS232 interface and software
supplied for down loading. Impact energy 2.207Nm. Engineering
units of results in N/mm2, MPa, psi, kg/cm2. For concrete
thickness greater than 100mm.
Proceq Profoscope Rebar Locator & Cover Meter
PRO,PROFOSCOPE (4926) AU
Rebar locator and covermeter. Short range
measurements to 95mm ±3mm accuracy. Long range
185cm accuracy ± 4mm. The unit will determine the
position of the rebars, the mid point between rebars,
Concrete cover, estimation of bar diameter & the
orientation of the rebar. Powered by 2 x AA batteries.
Battery life 15h with backlight 55h without.
Proceq Resistivity Meter
PRO,RESIPOD (4925) AU
Can determine the likelihood of corrosion and
the corrosion rate in concrete. 0 to 1,000kΩ
measurement range. USB interface, USB charging. Waterproof.
Proceq SilverSchmidt UN Concrete Test Hammer
Hilti PS1000 X-scan Concrete GPR System
HIL,PS1000 (4922) AU
A GPR system with 3 transmitters and
5 receivers that has been designed
to provide a 3D image of the location of reinforcement
bars and other metallic and non-metallic objects in concrete.
Accuracy ±10mm. It will measure to a depth of 300mm.
PRO,SIL-UN (4928) AU
Requires no corrections for angle of test,
simple one button operation, datalogging
capability with USB download and detailed
reporting capability. Impact energy 2.207Nm.
Compressive strength range 10 to 170MPa.
Battery Life >1,000 Impacts before recharging is required.
Pundit PL-200PE Ultrasonic Concrete Test System
Hilti PS38 Multidetector
PUN,PL-200E (4927) AU
HIL,PS38 (4918) AU
Can determine depth of perpendicular cracks,
slab thickness from a single side and it can
also locate and measure voids, pipes, cracks
parallel to the surface. It will estimate the
‘internal’ compressive strength of the concrete.
Designed to detect objects such as ferrous
metals (rebars), non-ferrous metals (copper
and aluminium), wood beams, plastic
pipes, electric cables in dry materials. Detects at depth
up 120mm. Location accuracy ±15mm. Depth accuracy
±5mm. Minimum distance between two objects 40mm.
Protimeter Moisture Measurement System
PRO,MMS-PLUS (4955) AU
Oversee your site with confidence
and rent a site monitoring kit from
TechRentals. View the kit on page 69
60
Moisture meter for detection of moisture in non conductive
solid materials such as wood and masonry. Two measurement
modes, search for qualitative measurements and measure mode
for precise and localised moisture content. Supplied with pin
type probes, deep wall probes, hygrometer probe and extension
cord for RH, ambient temperature or dew point temperature.
Hygrostick probe supplied for surface temperature measurement.
Logging software and RS232 computer interface supplied.
Construction
Underground Services Location
CScope CATXDSGV-KIT Cable and Pipe Locator
CSC,CATXDSGV-KIT (3730) AU
CSC,CATXDSGA-KIT MY
Industry standard locator used to determine
the exact location of buried pipes and cables.
Functions include; Power mode for detecting
live imbalanced cables to a depth of 3m, Radio
mode for detecting re-radiated radio signals to a
depth of 2m and Generator mode for detecting
conductors carrying the signal generated by the
C.Scope signal generator.
Vivax VLOCPRO Pipe and Cable Location System
www.techrentals.com.au
Utility Leak Detection
UE Systems UP3000 Digital Ultrasonic Leak Detector
UES,UP3000 (3810) AU
Displays dB levels. Readings can be stored
and downloaded. A tone generator is supplied
together with a stethoscope probe and a rubber
focusing probe. Interface software to download
readings is also supplied.
Ground Penetrating Radar
See also Concrete Testing Equipment on page 59-60
VIV,VLOCPRO (3740) AU
USRadar Ground Penetrating Radar System
Pipe and Cable locator with intuitive
menu system, colour display, peak,
null, left/right and orientation (compass)
response to support your preference.
Configured with 6 location frequencies,
power and radio modes. 10 watt transmitter can apply the
location signal by connection, induction or signal clamp.
Depth detection up to 6 to 9 meters in broad-peak mode.
USR,SEEK-SPR (3601) AU
Designed to locate buried objects. Typically used
for the location of cables and pipe, detection of
pipe and the detection of underground storage
tanks. For targets as small as 5cm diameter and
up to 4m depth.
Remote Concrete Pour Temperature
Sensing and Sample Control Using Modbus
TechRentals have developed a simple solution for the monitoring of the concrete curing
process that also provides ‘matched temperature’ control of the concrete pour samples.
The benefits include a more accurate estimation of concrete strength and potential
shortening of the period before additional construction can commence.
An application of the Modbus protocol has enabled the efficient implementation of concrete
pour temperature remote monitoring and also control of the storage environment of concrete
test. The system is sufficiently undemanding in installation for it to be supplied as a rental
system however many users would find it practical to have it as a standard tool.
A dataTaker model DT80M logger is used to gather 30 channels of thermocouple data at the concrete pour and the data is
linked to a second DT80M at a remote office location. The site data is monitored for obvious errors and faulty thermocouple
data is automatically rejected. The office logger controls a thermal bath and maintains this as an accurate analogue of the site
concrete pour temperature. Site samples are placed in the bath and thereby are maintained in closely matched conditions to
those in the construction. The samples can therefore be subjected to mechanical testing with a high degree of confidence.
This together with the precise monitoring of the site curing process considerably increases the confidence in the state of
the concrete. This allows for earlier formwork striking times with an earlier start to prestressing and consequently significant
savings. This system is simple to implement with the baths currently in use.
The first implementation of the system was in a remote location in Queensland.
The dataTaker data loggers and associated hardware are available from TechRentals who also wrote the associated software.
TechRentals sales engineers are always ready to offer advice on any aspect of test and measurement instrumentation
selection and use.
61
Construction
www.techrentals.com.au
Pipeline & Cavity Inspection
Pipeline & Cavity Inspection cont’d.
See also Endoscopes Borescopes Visual Inspection on page 41
Wohler VIS340 Service Camera Visual Inspection System 30m
Aqua Snakeeye Video Inspection System
AQU,SNAKEEYE3 (5166) AU
Handheld video system for remote
inspection work. Very light and
compact. Includes a 12.7cm TFT-LCD
display and 3cm diameter camera including illumination.
Various adapters are supplied for mounting the camera to: a)
your hand, b) a 45.7cm arm with 90 degree articulation, c) a 30m
extension cable or d) an arm which extends from 1.6 to 3.6m.
Includes memory card and will save images to card.
WOH,VIS340-PT (5160) AU
WOH,VIS340 MY
Compact colour video inspection system
with 26mm forward facing and 40mm Pan
Tilt colour cameras. Viewing angle 120°,
waterproof according to IP68(3 bar-30m) and
IP67(2 bar-20m) respectively. Bright white LEDs on 30m of
flexible push rod with metric markings. Battery powered 7” high
resolution colour screen with removable monitor and SD video
recording. Applications incl damage analysis in water/drainage/
sewer pipes, inspection of hollow spaces, ventilation, machines,
control panels, exhaust systems and production surveillance.
Vivax Pipeline Camera Inspection System
VIV,VCAM-60M (5155) AU
60 meter pipeline inspection system with self
leveling camera (D33/SL, 41mm diameter)
will record MPEG4 videos and provides a
keyboard, titler and sound system to add up
to 16 pages of text and an audio commentary.
Can be uploaded via a USB interface to a
computer allowing copies to be made or images to be captured
for inclusion in reports. Camera includes a sonde with 512Hz,
640Hz and 33kHz modes. Submersion depth up to 1 bar (10m).
Vivax Pipeline Camera Inspection System
Wohler VIS-350 Service Camera Visual Inspection
System 30m
WOH,VIS350-PT (5159) AU
30 meter compact colour video inspection system
with 26mm forward facing and 40mm Pan Tilt
colour cameras. Waterproof according to IP68
(3 bar-30m) and IP67(2 bar-20m) respectively.
Adjustable illumination, camera orientation/gravity and degree of
inclination display, 8.9kHz sonde in each camera, memory 1 hr/Gb.
Applications include damage analysis in water/drainage/sewer
pipes, inspection of hollow spaces, ventilation, machines,
control panels, exhaust systems and production surveillance.
VIV,VCAM-120M (5196) AU
120 meter pipeline inspection system with self
leveling camera. Will record MPEG4 videos
and provides a keyboard, titler and sound
system to add up to 16 pages of text and an
audio commentary. Can be uploaded via a USB
interface to a computer allowing copies to be
made or images to be captured for inclusion in reports.
Camera includes a sonde with 512Hz, 640Hz and 33kHz modes.
Distance Measurement & Surveying
See also Light Meters, UVA/B/C Measurement on page 68
ikeGPS Precision GPS and Laser Distance and Camera System
IKE,300PRO (5301) AU
Intergrated precision GPS (1.5m), laser based
range finder (300m), Precision compass,
precision inclinometer and camera system.
Used to geolocate and document. It can be used
to remotely dimension cable and buildings, etc.
TechRentals Social Media
Have greater access to news, product tips and information via a range of social media channels. With over
100 videos on our YouTube channel and regular industry related updates on twitter, LinkedIn and Google+
you will always be informed. So subscribe and follow to stay up-to-date and in-touch with our friendly team
and make the most of your test and measurement equipment.
Google+
Twitter
YouTube
LinkedIn
http://www.google.com/+TechRentals
http://www.youtube.com/techrentals
62
http://www.twitter.com/techrentals
http://www.linkedin.com/company/techrentals
Communicate - Anywhere, Anytime!
Stay connected with the ones you love with 24/7 access to voice, email and data
Need a Satellite Phone?
Need a Call Plan?
Don’t get caught without reception in remote
areas - take a Satellite Phone. The perfect
device to maintain a critical lifeline no matter
where you are, it is better to be safe than sorry.
TR Telecom have developed a range of satellite
phone call plans to suit our customers’ needs.
Whether it’s for short or long term requirements,
low or heavy usage, business or personal use, we
have a call plan for you.
Save money when you rent
 Only pay for the calls you make
 No monthly access fees
 No capital outlay
 Short, medium and long term rental options
 Ongoing service and full technical support
 Phone comes in a ‘Grab n Go’ pelican case
Satellite Phone Rental 1800 222 327





Iridium/Inmarsat pre-paid and postpaid options
Quick and easy setup
Low call, SMS and data rates
SIM cards express posted to you
24/7 technical support from our friendly staff
here in Australia
Call Plans 1300 550 014
Your friends and family
can text you for FREE
from our website.
Ask us how!
Save Money – Think Rental
TR Telecom is the only iridium partner in Australia who
offers air time, repairs, parts and sales. Call us today!
telecom
www.trtelecom.com
Melbourne | Sydney | Newcastle | Brisbane | Townsville | Adelaide | Darwin | Perth
TS0181
Did you know you can rent a SIM card?
Environmental & OHS
Environmental Gas & Vapour Meters
Personal Gas & Vapour Monitors
Airborne Dust & Particle Meters
Air Quality & Heat Stress
Moisture & Humidity Meters
Noise & Sound Analysers
Radiation Monitoring & Protection
Water Quality, pH Meters & Eletrochem
Light Meters, UVA/B/C Measurement
Weather Stations
Environmental Flow Meters
Balances & Scales below 8kg
www.techrentals.com.au
Environmental Gas & Vapour Meters cont’d.
Oldham MX21 Plus Gas Monitor for Sulphur Dioxide SO2
OLD,MX21-SO2 (5927) AU
Portable gas detector for personal, workplace or space monitoring
of sulphur dioxide (SO2) in the range 0 to 30ppm. Operation in
passive or pumped modes, with sampling tube and flexible probe.
Data logging, with software included for download to serial printer
or computer. Rolling storage of up to 48h data (at 1min intervals)
in multiple groups. Rechargeable battery.
PetroSense PHA-100 Petroleum Hydrocarbons in Water Detector
PET,PHA-100 (5945) AU
Portable hydrocarbon analyser for insitu realtime
petrochemical contamination. Measures Total
Petroleum Hydrocarbons (TPH) in water and water
vapour. Uses a fibre optic chemical sensor (FOCS).
Measures 0.1ppm xylene in water ad < 10ppm in
vapour. Accuracy ±15% of readings. Response time
<5sec. Certified to EPA Method 8020.
Environmental Gas & Vapour Meters
See also Combustion, Flue & Industrial Gas Analysers on page 51
Aeroqual 500L Portable Logging Ozone Monitor
AER,500L (5958) AU/MY
Portable ozone monitor fitted with low
concentration-range detection head. Operating
range 0 to 0.5ppm ozone with display in ppm
or mg/m3. Gas sensitive semiconductor [GSS]
sensor for accurate low-level measurements,
T90 response approximately 100s. Operation
from mains power supply or battery pack (4h operation).
Internal data logging for 8,000 points with software and
cable for download to PC, or data logging direct to PC.
Application for indoor air quality measurements.
Geotech Landfill Gas ExMonitor
GEO,GEM5000 (5940) AU
Measures CH4, CO2, O2, CO & H2S. Designed
for spot measurements. Intrinsically safe and has
a built in GPS system. It can also measure flow
rates from bore holes and perform landfill gas
energy calculations.
GasCheck 3000 Portable General-Purpose Leak Detector
ION,GASCHECK3000 (5906) AU
Micro thermal-conductivity sensor for high-sensitivity detection of
gases with a thermal conductivity different to that of air, including
helium, carbon dioxide, refrigerants, sulphur hexafluoride, natural
gas, etc in 5 groups. Direct reading of leak rate in ml/sec with
audio and visible signals. Detection limit for helium 2E-5ml/s.
Battery Powered.
Ion Science Gascheck Helium, Butane & SF6 Detector
ION,GASCHECKG3 (5907) AU/MY
Microthermal conductivity gas detector. Reading
in cc/s, g/yr, mg/m3 or ppm. Detects most gases
however particularly suited to ammonia, argon,
butane, helium, hydrogen & SF6. Calibrated
against Helium. Battery Life 40h. Sensitivity
(cc/s) He 1x10-5, CH4 5x10-5, R12 5x10-5,
Ar 1x10-4. Accuracy 5% of displayed reading
+ 1 digit. Response 1s. Flow rate 2cc/min.
Operating -20 to 60°C. Data logging, stores 10 readings.
64
PPM 400 Portable Formaldehyde Meter
PPM,FORM400 (5962) AU
Portable Formaldehyde meter for measuring airborne
formaldehyde in the workplace. Electrochemical
sensor, with internal pump for rapid response.
Operating range 0.05 to 10ppm with readout on
4 digit LCD display. Kit includes field calibration
standard. Operates from 9V alkaline battery.
Minirae 3000 Advance Handheld VOC Monitor
RAE,MR3000 MY
Handheld volatile organic compound (VOC) detector.
Photoionisation detector’s (PID) extended range of 0
to 15,000 ppm, ideal for applications from industrial
hygiene, to leak and HazMat detection. RF modem
allows real-time data transmissions with a base
controller located up to 500 feet (or two-miles with
optional RAELink3 portable modem) away from the
MiniRAE 3000 detector. A personal computer can
be used as the base station for a Mini-RAE 3000 system.
RAE Systems PPB Photoionization (PID)
Volatile Organic Compound (VOC)
RAE,PPB3000 (5928) AU
Handheld volatile organic compound (VOC) gas monitor.
Its photoionisation detector’s (PID) extended range of
1 ppb to 10,000 ppm makes it an ideal instrument for
applications from HazMat/Homeland Security, industrial
hygiene, to Indoor Air Quality and military applications.
See also RKI,EAGLE2 Gas Detector Confined Space Plus
PID on page 65
RH Systems 973-SF6 Analyser
RH,973-SF6 (5910) AU
Measures the purity of SF6 gas. Uses a fast
acting mirror system to measure humidity.
Displays direct % purity. Includes a gas
recovery system. Includes built in test for
instant verification of the system accuracy. Dew Point
measurement -55 to 20°C, pressure 0.1~30 Bar. Accuracy ±0.5°
dew point. Gas coupling is done via a quick connect fitting.
Environmental & OHS
Environmental Gas & Vapour Meters cont’d.
www.techrentals.com.au
Airborne Dust & Particle Meters
Wika GA-15 SF6 Leak Detector
TSI 8525 P-Trak Ultrafine Particle Counter
WIK,GA-15 (5909) AU
TSI,8525 (5877) AU
A fast response SF6 leak detector which will detect
concentrations of SF6 down to 3ppmv. Only detects
SF6 and is unaffected by moisture and wind.
Range 0.01 to 5 x 105 particles/cm3. Particle size range 0.02 to
greater than 1micron. Includes PC software and cable. Suitable
for detection of ultrafine particles associated with pollutants.
Battery powered (8h operation using alkaline batteries).
Personal Gas & Vapour Monitors
Alcolizer Wall Mount Alcohol (BAC) Breath Tester
ALC,WM3 (5980) AU
Wall mount Alcohol Breath Tester (BAC or
breathalyzer). Automatic recalibration every 24hrs.
Very simple to use. Australian Standards Certified
- AS 3547 Type III Low cost maintenance and
consumables (standard drinking straws).
TSI 8530 Aerosol Monitor and Logger
TSI,8530 (5873) AU/MY
Portable dust and particle monitor, light
scatter photometer. Measure concentrations
corresponding to PM1, PM2.5 & PM10. Aerosol
concentrations 0.001 to 150mg/m3. Used for
industrial/occupational hygiene surveys, indoor
air quality monitoring, outdoor environmental
monitoring, baseline trending and screening, etc.
BW Bump & Logging Download for BW,MICROCLIP
BW,BUMP (5938) AU/MY
Automatic calibration testing and data
management system for the BW microclip gas
detection equipment. Carries out fully automatic
“hands-free” calibration and functional bump
test. It also enables data collected during
operation of the BW microclip to be downloaded.
TSI Environmental Enclosure for the TSI,8530
TSI,8530-ENC (5875) AU/MY
Enclosure to suit the TSI,8530. Includes two
additional batteries and charger. Includes
waterproof enclosure and heat shield and
enclosure stand.
BW Gas Alert Micro Clip Confined Space 4 Gas Detector
BW,MICROCLIP (5937) AU/MY
Continuous LCD shows real time gas concentrations.
Simple 1 button operation. Measures:- H2S 0 to
100ppm (1ppm resolution), CO 0 to 500ppm
(1ppm resolution), O2 0 to 30% (0.1% resolution)
and Combustible gases 0 to 100% LEL (1%
resolution), 0 to 5% v/v (0.1% resolution). Alarms: visual, vibrating
and audible (95dB), Low, High, STEL, TWA and OL (over limit).
Lithium polymer battery life 12hrs (typical) recharge time <3hrs.
TSI Environmental Enclosure for the TSI,8530 Dusttrak II
TSI,8530-ENC-S (5876) AU
Enclosure to suit the TSI,8530. Includes two additional batteries
and charger. Includes waterproof enclosure.
TSI 8533 Aerosol Monitor and Logger
TSI,8533 (5870) AU
BW Sampling Pump for BW,MICROCLIP
BW,GA-SPAK (5939) AU/MY
Motorised sampling pump that provides 300ml/min for remote
sampling up to 18m away. Runs continuously for 30hrs on
batteries. Includes 3m sampling hose. Includes built in water
traps and particulate filter.
BW GasAlertExtreme Single Gas Ammonia NH3 Detector
Portable dust and particle monitor, light scatter photometer.
Measure concentrations corresponding to PM1, PM2.5 and PM10.
Aerosol concentrations .001 to 150mg/m3. Used for industrial/
occupational hygiene surveys, indoor air quality monitoring, outdoor
environmental monitoring, baseline trending and screening etc.
Will size particles in three sizes PM1, PM2.5 and PM10.
BW,GA-NH3-KIT (5935) AU/MY
TSI AM510 Personal Aerosol Monitor; CSA & ATEX IS approvals
Single gas sensor for NH3 (Ammonia). There are two in the kit
including a bump station with 50ppm gas.
TSI,AM510 (5871) AU
RKI Eagle2 Gas Detector, Confined Space plus
Photoionisation (PID)
RKI,EAGLE2 (5930) AU
Measures 4 confined space gasses CH4, O2, H2S
and CO plus a PID. Alkaline 18 hours or Ni-MH 20
hours capability. Powerful long-life pump up to 38m
range. Low flow pump shut off and alarm. Datalogging
standard. IrDA communications port. Autocalibration/ single
gas calibration. Internal hydrophobic dust filter. External probe
with hydrophobic filter. Ergonomic RFI/EMI/chemical/weather
resistant enclosure. Intrinsically safe design, CSA approval.
See also RAE,PPB3000 PPB Photoionisation (PID) Volatile
Organic Compound (VOC) on page 64
Wearable dust monitor. Built in Impator allows you
to chose either ‘none’, 1, 2.5 or 10µm particle
sizes. Datalogs TWA in the range of particle
concentrations from .001 to 20mg/m3 Runs
9.2hrs on rechargeable NiMH batteries. USB
download capability. CSA & ATEX IS approvals.
New items are being added to the inventory
constantly, so if you cant see what you’re
looking for, please call us on 1800 632 652.
65
Environmental & OHS
www.techrentals.com.au
Air Quality & Heat Stress
Air Quality & Heat Stress cont’d.
Casella Microtherm WBGT Area Heat Stress Monitor
TSI Q-Trak plus Indoor Air Quality Monitor with Logging
CAS,MICROTHERM (5868) AU
TSI,8554 (5860) AU/MY
Portable area heat stress WBGT monitor
with real-time graphical display. Measures
heat stress potential [WBGT index] according
to ISO7243. PRTD sensors with internal
calibration-reference for wet-bulb, dry-bulb
and globe temperatures. Large LCD display
for numerical or graphical indication of temperatures and
processed values for WBGT [indoor/outdoor plus TWA], relative
humidity and dewpoint. Simple keypad/menu setup. Data logging
for up to 32 separate runs and 49,100 records, with interval
30s to 1h. RS232C port with included PC software for download
and reporting or realtime display. Low water-level warning, and
settable audible/visible WBGT alarm. Handheld, free-standing or
tripod-mount. Battery operated.
Indoor air quality (IAQ) monitor for temperature
and humidity measurements, CO and CO2
concentrations. Humidity range 0 to 95%,
temperature range 0 to 50°C. Electrochemical
cell for CO 0 to 500ppm. NDIR cell for CO2 0 to
5,000ppm. Data logging for 48,671 data points
with interval adjustable 1s to 1h. Fitted with
RS232 interface, and software included for download, storage
and reporting. Battery or mains operation with AC adaptor.
Moisture & Humidity Meters
GE Panametrics PM880 Industrial Moisture Analyser
PAN,PM880 (5911) AU
Testo 635-2 Humidity, Temperature & Dewpoint Meter
TES,635-2 (5859) AU
Portable humidity meter fitted with robust
stainless probe with sintered filter-cap for general
or duct measurements to 120ºC, and fast-action
K-type surface temperature probe. Displays
relative humidity, absolute humidity, dew point,
degree of humidity, enthalpy, temperature, and
differential temperature (dewpoint~surface).
Operating range 2~98%RH (±2%). Air temperature
-20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1).
Internal memory for 10,000 values with USB interface, cable
and software for download and presentation. Battery operated.
Intrinsically safe moisture analyser for
compressed air systems, non-corrosive
gases & hydrocarbons such as natural gas
(IS certification to ATEX and CSA). Displays
dew point, moisture concentration, pressure
& temperature. Dew point calibrated
measurement range -80 to 20°C with data to -110°C. Pressure
range 7 to 69 Bar limited by sensor, gauge and safety-valve
(operating range from 5µHg). Temperature range -30 to 70°C.
Gas flow operating range from static to 10,000cm/s velocity.
Supplied with compact sample system with gauge, safety-valve,
sampling valves and fittings (¼” Swagelok). Data logging of
up to 100K moisture points, with infrared port and software
for download. Battery powered only (15-24h operation) with
second battery and charger (note charger is not IS).
Testo 635-2 Temperature & Dewpoint Meter for
Compressed Air Systems
Noise & Sound Analysers
TES,635-2-HPD (5912) AU
See also Vibration Analysis on page 55-56
Portable humidity meter fitted with 0636 9836
HPD pressure dewpoint probe for measurements
in compressed air systems, -60 to +50ºC tpd,
0~100%RH. Internal memory for 10,000 values
with USB interface, cable and software for
download and presentation. Battery operated.
Testo 645 Humidity & Dewpoint Meter
TES,645-1 (5858) AU
Portable humidity meter fitted with robust
stainless probe for ambient work or duct
measurements to 120°C. Displays relative
humidity, absolute humidity, dew point,
degree of humidity, enthalpy and temperature.
Operating range 2 to 98%RH [±2%], -20
to 120°C [±0.4/0.5]. Battery operated.
TSI Q-TRAK IAQ Monitor CO2, CO Temperature & Humidity Logger
TSI,7565 (5861) AU
Measures CO2 0 to 5,000ppm ±3%,
temperature 0 to 60ºC ±0.6ºC, humidity
0 to 95% ±3%, CO 0 to 500ppm ±3% and
barometric pressure 517.15 to 930.87mmHg
±2%. Calculates dew point, wet bulb and
percent outside air. Displays 5 measurements
simultaneously. User selectable logging interval
and start stop times. Stores 39 days data at
1min intervals 56,035 data points. This unit
also has external thermocouple measurements.
66
ARL NGARA Environmental Noise Logger
ARL,NGARA (5690) AU
Can be configured to record all sound
continuously so noise data can be post
processed. It can provide logged data,
WAV data & alarm/triggered details.
Type 1 microphone provided.
B&K 2238E Type 1 Integrating SLM Enhanced
Software & Logging
BK,2238E-NATA (5678) AU
Type 1 (class 1) Integrating sound level meter with additional
functions including enhanced software, frequency analysis and
data logging. Standard routines include functions for workplace
measurements and general sound-level checks; enhanced software
(firmware) offers additional measurements and statistics for
assessment of environmental noise problems; frequency analysis
automates measurements in the 9 single octave bands and 29
1/3 octave bands. Supplied with field calibrator. Compatible with
BK,7815 Noise Explorer Environmental software for download,
data analysis and display.
B&K 4448 Badge Dose Meter IS Kit of 3
BK,4448-IS-3KIT (5680) AU
Kit of 3 Intrinsically safe noise dose meters. The kit includes a
NATA calibrated 4231 Type 1 calibrator. These are badge type Dose
Meters, shoulder mounted, cable free and simultaneously measure
all parameters required by noise at work standards. Simple two
button operation. Rechargeable battery provides several working
days of measurement.
Environmental & OHS
www.techrentals.com.au
Noise & Sound Analysers cont’d.
Radiation Monitoring & Protection
Digital Audio Test Set comprising of NTI Digirator & NTI Digilyser
See also E & H Field Strength Meters on page 10-11
NTI,NT-DAS (5684) AU
Audio Excel Line for digital audio signals.
System including the Digilyzer and Digirator for
producing digital audio signals and analysing
those digital audio signals up to and including 5.1
surround sound. Up to 192kHz 24bit, AES3,S/PDIF,
TOSLINK & ADAT. ync input (AES3, Word Clock,
Video). Supports Dolby Digial, E, PL II, DTS.
Channel transparency check. Channel delay measurement.
NTI XL2+M2210 Sound Level Meter
NTI,XL2+M2210 MY
Sound Level Meter comes with Class 1 microphone,
acoustical analyser options and audio analyser
options. Applications in sound installations, live
sound, studio, broadcast and environmental
noise measurements. Logging all data or subsets
in selectable intervals. Recording of wav-files
(ADPCM), a new wav-file starts every 12 hours
(max. wav-file size 512 MB). Real time analyzer with frequency
resolution: 1/3 octave, 1/1 octave, wide band and frequency
range: 6.3Hz to 20kHz. Frequency weighting: A, C, Z. USB
interface with PC analysis tool.
Rion NL-04 Sound Level Meter
RIO,NL-04 MY
Meets IEC type 2. Five measurement functions: Lp(SPL), Leq, LAE,
Lmax & Lx(L5,L10,L50,L90,L95). 6 automatic measurements &
data store. Built-in RS232C interface for computer communication.
70dB dynamic range (digital display), 27 to 130dB (A) measuring
range. Wide range of time settings for Leq, LAE, Lmax & Lx; 10s,
1, 5, 10, 15, 30min, 1, 8, 24h & manual time setting (up to 99h
59min 59s). RMS: fast, slow,10ms. 4 digit LCD display, 0.1dB
resolution, updated every second, plus 60dB analogue display
display 1dB resolution showing the instantaneous value. Memory
battery back-up. AC & DC signal o/p for level expanding system by
optional filters, memory card & others.
Fluke 481 Radiation Survey Meter
FLU,481 (5580) AU
Provides exposure measurements in mR/hr to
50R/h (0.55v/hr). Detects skin-dose, deep-dose
and X-ray radiation. Measures dose & dose rate.
HPI Cypher 5000 Digital Radiation Alert Monitor
HPI,CYPHER5000 (5583) AU
Alpha, Beta, Gamma and X-ray radiation monitor.
Meter, LED, audible indication and detachable probe.
Range 0.1 to 1,000,000 CPM; Accuracy 1% or 2 digits.
Narda 8217 Microwave Oven Survey Meter
NAR,8217 (5553) AU
For oven power measurement complete with beaker and
thermometer. Calibration frequency 2.45GHz. Measurement range
0.5 to 10mW/cm2. Battery operated.
Narda RadMan Personal RF Field Radiation Monitor
NAR,RADMAN (5557) AU
Personal monitor and leakage detector for high
frequency electromagnetic fields. Simultaneous E
and H field measurements with audible and visual
alarms. Frequency range H field 27MHz to 1GHz; E
field 1MHz to 40GHz. Operation as personal monitor
with compensation for human body absorption, or
with isotropic detection for RF leakage sensing and
simple four-level measurement using LED indicators.
Water Quality, pH Meters & Electrochem
Hydrolab Minisonde 5 Multiprobe Water Logger
HYD,MS5 (6020) AU
Rion NL-32 SLM with RTA
RIO,NL-32 MY
Precision integrating sound level meter to IEC type 1 (class 1)
specification, with NATA calibration. Fitted with internal Compact
Flash Card reader and supplied with NC-74 field calibrator.
Frequency range 20 to 20,000Hz with weightings A, C, and flat.
Time weightings fast, slow and impulse. Measurement range (A) 28
to 138dB. Broadband measurement functions Lp (SPL), Leq, Lmax/
min, Lae, Lx, and selectable auxiliary functions with manual or auto
storage [logging]. Measurement time (Leq) from 10s to 200h. Inbuilt
memory for up to 100 data sets, or to limit of fitted CF card using
manual or auto storage. AC or dc outputs, RS232C interface and
cable CC-93 for serial printer. Supplied with NX-22RT card for real
time 1/1 and 1/3 octave analysis and display, for measurement
functions Lp, Leq, LE, Lmax and display of AP (all-pass) AP(A) and
1/1 or 1/3 octave values as selected, with manual data storage
only to NX-22RT card. Download of card-data to PC requires
flashcard reader. Alkaline batteries (24h operation) or AC adaptor.
Rion NL52EX SLM with NX42RT Octave and 1/3 Analyser
Minisonde 5 multiprobe water/borehole logger,
including ‘Surveyor’ data collection system
with GPS. Includes sensors for Dissolved
Oxygen (HACH LDO), Conductivity, pH, Redox
(ORP), Turbidity (Self-Cleaning), Temperature,
Depth (0 to 25m) and GPS position. Includes
the surveyor data aquisition system so no laptop is needed
for download or data collection. Includes a 25m cable.
ISCO 6700 Series Water Sampler
ISCO,6712 (6057) AU
Advanced water sampler for fully programmed
collection. Samples are collected in up to 24
disposable plastic containers based on time,
flow, and/or parameter set points. Fitted with
NEMA 4X,6 (IP67) sealed controller featuring
an exclusive, built-in pump.
OTT KL010-150 Ground-water Depth Measurement
Contact Gauge 150m
RIO,NL52EX-NX42RT (5670) AU
OTT,KL010-150 (6065) AU
Type 1 Sound Level Meter, including the Octave
and 1/3 Octave measuement option NX42RT. This
meter can be used to check NC levels for compliance
checking. The instrument includes a NATA calibrated
calibrator. All data is saved to an SD card.
Contact gauge for portable depth to water measurement. Used for
wells, observation pipes, bore holes and control pumping tests.
150m depth of tape. As soon as the probe touches the water
surface an acoustic signal beeps and the lamp on the instrument
lights up. The depth is read from the measuring tape in meters.
67
Environmental & OHS
Water Quality, pH Meters & Electrochem cont’d.
TPS 90FL-T Water Quality Meter
www.techrentals.com.au
Light Meters, UVA/B/C Measurement
Hagner EC1-X Lux Meter NATA Calibrated
TPS,90FL-T (6028) AU
HAG,EC1-X (5600) AU
Field meter and logger for water
quality measurements. Configured
with independent probes for pH,
conductivity/salinity [TDS] temperature,
dissolved oxygen [DO] and turbidity.
Cables 5m with probe holder and
safety harness. LCD display readout with simultaneous
display of all measurements. Manual, “notepad” storage
or automated data logging for up to 1,808 sets of readings
by time and date. RS232C interface, with WinTPS software
included. Supplied with rechargeable battery, and clip-lead
for operation from a 12V source such as a car-battery.
Digital illuminance meter with NATA
certification. measurees from 0.1~200,000
lux. Has a remote measurement head on 2m
cord. Accuracy +/- 3% of range +/- last digit.
Battery Operated.
TPS WP-80 pH and Temperature Meter for Testing Meat
TPS,WP-80M (6002) AU
Portable hand-held meter for pH, mV and
temperature. The instrument is capable
of applying Bendalls equation to the pH
reading for Meat Standards Australia grading
requirements. Supplied with combination pH
electrode and separate temperature sensor
on 1m cables. Operating ranges 0~14pH and
-10~120ºC [automatic sensor recognition
with auto pH correction 0~100ºC]. Case water resistant to
IP67, connectors to IP65. Menu driven, with alphanumeric
display. Auto storage of time and date of last calibration
for GLP. Memory for 2400 readings of data, time and date,
for Notepad results collection, or for AutoLog with logging
intervals between 1s and 90h. Fitted with RS232C interface
and supplied with download-software, charger and solutions.
Rechargeable NiMH battery gives up to 50h operation.
TPS WP-88 Turbidity & Temperature Meter with 8m Cable
TPS,WP-88 (6031) AU
Portable hand-held turbidity and
temperature meter for field or laboratory
use. Sensor probe diameter 45mm,
with 8m cable. Turbidity ranging 0.1 to
200/2,000NTU ±1NTU with autoselection.
Temperature compensation and
sensor range 0 to 60ºC ±0.1ºC. Case
water resistant to IP67, connectors to IP65, with detachable
cable and sensor. Menu driven, with alphanumeric display.
Auto storage of time, date and results of last calibration for
GLP. RS232C interface, and memory for 150 readings of data,
time and date, for Notepad results collection, or for AutoLog
results collection with logging intervals between 1min and
24h. Rechargeable NiMH battery gives up to 50h operation.
Supplied with download-software, charger and calibration solutions.
Hioki 3423 Lux HiTester Digital Illuminance Meter
HIO,3423 (5602) AU/MY
Manual switching and autoranging. LCD
display with 3½ digits (“1999”) for five
measuring ranges to 20/200/2,000lux
in 1-count steps, 20,000lux in 10-count
steps and 200,000lux in 100-count steps with accuracy ±4%.
Response time in autorange mode 5s (2s in manual range
mode). Autozero, hold and backlight function with delay for taking
readings in low light. Input for ac power adaptor, connecting-cable
to allow separation of sensor unit and meter, and 200mVdc
analogue output with cable. Battery powered.
ILI 1400ABC Radiometer for UV Measurements
ILI,1400ABC (5614) AU/MY
International Light model 1400 radiometer
with backlit LCD display, autozero and
autoranging. Continuous reading with hold
function, or integrated “dose” measurement
up to 24h. Smart detectors with storage of
units and detector-calibration data. Analogue recorder output.
Mains adaptor or battery power. Supplied with three sensors: UV
actinic hazard (UVC with B & A components matched to OSHA
requirements), range 2.50e-7 to 2.50e-3 W/cm2 eff. UVB + A
(total “solar” radiation), range 1.16e-7 to 4.07e-1 W/cm2.
UVB, range 1.54e-6 to 1.54e-2 W/cm2.
Minolta CL-200 Chroma Meter for Illuminance & Colour Measurement
MIN,CL-200 (5610) AU
Konica Minolta model CL-200 portable colour
meter. LCD display for illuminance, tristimulus
values, chromaticity, correlated colour temperature
and colour difference. Illuminance range 0.1 to
99,990lx ±2%. Colour accuracy ±0.002 [xy]
or ±20°K [Tcp]. Fitted with RS232C interface.
Battery powered, or AC adaptor.
Yokogawa 51001 Lux Meter NATA Calibrated
YEW,51001-NATA (5607) AU
Digital illuminance meter with NATA certification. Measuring
range from 0 to 99.9/999/9,990/99,900/999,000lux.
Accuracy <3,000lx 4% ±1 digit >3,000lx 6% ±1 digit.
Autoranging with silicon sensor. Battery operated.
Weather Stations
Van Essen DI502 Mini-Diver Borehole Level Logger
& Barometer 20m
VAN,DI502 (6061) AU
Mini-diver borehole level logger 20m, 1cm
accuracy. Kit includes barometric logger for
atmospheric pressure compensation. Will
also log temperature. Temperature range
-20 to 80ºC. Accuracy 0.1ºC. Size 22 x
90mm. Stores 24,000 measurements per
parameter. Stainless steel housing barometric (l/c)
logger for compensation. 10 year battery life.
68
Vaisala WXT520 Weather Station
VAI,WXT520-KIT (5885) AU
Completely solid state measurement of rainfall to
0.1mm, rain intensity 0.1mm/hr, rainfall duration,
hail duration and intensity, barometric pressure 600
to 1100hPa, relative humidity 0 to 100%, wind speed 0 to 60m/s,
wind direction and temperature -52 to 60°C. The instrument is
logged using a Datataker DT80M and at the a press of a button the
data can be downloaded to a memory stick. Daily summary reports
are email once per day. The system includes a stand and will run
continuously, it includes a solar panel to keep the battery charged.
Environmental & OHS
Environmental Flow Meters
See also Flow Meters for Liquids & Gases on page 49
www.techrentals.com.au
Environmental Flow Meters
Unidata 6526B-21LCD Open Channel Liquid Flow
Logger with LCD Module
Global FP111 Digital Water Velocity Meter
UNI,6526B-21LCD (6141) AU
GLO,FP111 (6147) AU
Open channel flow logger with field LCD display module and 10m
cable (2m depth rating). Measurement and logging of flow-velocity
(by Doppler), depth (by pressure) and temperature. Programmable
for flow-channel profile (laptop PC required for in-situ programming
via RS232C). Operating temperature range 0 to 60°C. Velocity
21 to 5,000mm/s ±2%; depth 0 to 2,000mm ±2%; temperature:
-17 to 60°C ±0.1°C; log-interval 5s to 1 week; memory 120,000
samples. Programmable output to control devices such as water
samplers. Detects and measures reverse flows. Charger and
batteries supplied. Workhead dimensions 290 x 70 x 25mm.
Portable flow probe - current meter for water
velocity measurements in streams, channels and
partially filled pipes. Propeller sensor in 50mmØ
housing, fitted to telescopic handle [1.8m] with
gauging marks to 900mm depth. Digital LCD flow
meter display for instantaneous liquid velocity and
average, maximum, stopwatch or clock. Minimum
depth about 50mm. Range 0.1 to 4.5m/s ±0.05.
Hydrological Services Universal Current Meter OSS-B1
HYS,OSSB1 (6145) AU
Water current meter for measurement of
flow velocity in rivers, streams, channels and
open water. Robust streamlined stainless
body fitted with high precision 100mmØ fan
[flow range 0.025 to 5m/s]. Set of stainless
wading rods for depths to 3m. Rechargeable
“Hydromate” ruggedised field computer with IP65 case.
Storage of fan calibration formulae for direct readout of
volume-flow. Touch screen entry for set up, input, storage and
download. Supplied with PC download software and cable.
Balances & Scales below 8kg
A&D Mercury MX50 Moisture Balance
AND,MX50 (4440) AU
Maximum sample weight capacity 51g, weight resolution 0.001g,
moisture content accuracy over 1g 0.10%, over 5g 0.02%.
Halogen lamp used for heating, 400watt max. Drying temperature
50 to 200ºC. Measurement programs 20 sets, measurement
mode moisture content, wet or dry, dry content, ratio, weight.
Heating mode standard, automatic, quick, timer, manual.
Display large VFD, interface RS-232C, CD-ROM S/W supplied.
Pan sample size diameter 85mm.
Oversee Your Site With Confidence
A TechRentals site monitoring kit can warn you of potential problems
View the
benefits of Long
Term Rental!
Being informed that your work site doesn’t meet the required standards could lead to costly liabilities. Consequences
can be exacerbated if a construction site is found to be particularly hazardous or environmentally detrimental.
Excess ground vibration, noise, dust, and runoff pollution, are all common, but serious considerations for those
in construction.
Monitoring work sites is an inexpensive way to be sure that all state and council regulations are adhered to, while
simultaneously satisfying Corporate Social Responsibilities (CSR). You can do this simply with a work site monitoring
kit from TechRentals.
Kit Includes:
3 Ground vibration logging
Profound Vibra Ground Vibration Logger
3 Water run off analysis
TPS 90FL-T Multi-function Water Quality Meter and Logger
3 Noise logging
ARL NGARA Environmental Noise Logger
3 Dust monitoring
TSI 8533 Aerosol Monitor and Logger
69
Notes
70
TechRentals Business Partners
• Acoustic Research
Laboratories
• Anritsu
• EXFO
• Flir
• Fluke
• Fluke Networks
• GridSense
• JDSU
• Keysight Technologies
• Megger
• Testo
TechRentals are distributors and resellers for:
3 Anritsu
3 JDSU
3 Megger
3 Gridsense
3 Acoustic Research Laboratories
3 Kingfisher
3 Flir
TechRentals - The perfect solution!
TechRentals vast fleet of equipment offers a range of solutions to many markets. These include
the Aviation, HVACR, Defence, Electrical, Mining, Mechanical and Telco markets. If you can’t find
the equipment you’re looking for, our international partner network gives you access to an even
larger and diverse inventory to help satisfy your requirements.
It’s important to remember that renting is much more cost effective than to purchase outright
(see page 29). This enables you to preserve capital for other parts of your business. Should you
need to eventually own the assets, TechRentals offer a Rental Purchase Option. No matter your
need, we will find you the assets you require when you want them.
71
Environmental & OHS
www.techrentals.com.au
Our strength lies in our strong technical capacity and the synergies
between our different business units.
Test and Measurement
TechRentals offers specialised test and measurement equipment for a wide range
of industries. Products offered encompass electrical power measurement and
analysis, general industrial applications, physical measurement, radio frequency,
environmental and OH&S, data and telecommunications, electronics and more.
The leader in the industrial rental arena for more than 40 years, TechRentals also
offers Long Term Rental (LTR) solutions and flexible purchasing options that can be
tailored to your specifications.
1800 632 652
1800 88 7368
rent@techrentals.com.au
sales@techrentals.com.my
techrentals
www.techrentals.com.au
www.techrentals.com.my
Radio Communications
TR Hirecom is Australia’s largest two way radio communications rental company,
and has been providing radios and systems to suit the Security, Events, Hospitality,
Construction, Manufacturing, and Petrochemical industries for the past 15 years.
Offering the latest in digital technology and a choice of IS/FM/ATEX rated radios,
we have a solution for just about any application.
1800 222 327
rent@trhirecom.com.au
hirecom
www.trhirecom.com.au
Satellite Communications
TR Telecom offers a range of satellite telephony products (for rent or purchase)
from Iridium and Inmarsat, as well as prepaid and postpaid call plans.
Global satellite data solutions are also available through Iridium’s Short Burst
Data (SBD) and Inmarsat’s Broadband Global Area Network (BGAN). Please
contact our customer support team for more information, or view our full
range of satellite communications equipment at our online shop.
1300 550 014
satellite@trtelecom.com.au
telecom
www.trtelecom.com.au
Calibration
TR VMS are an Authorised Service Agent for Barfield Aviation, Megger Electrical,
and Stahlwille Torque products, with customers in the defence, manufacturing,
aviation and other high tech sectors. Our state-of-the-art labs give you the benefit
of the most efficient and current instrument calibration and repair services. As
a NATA accredited ISO/IEC 17025 provider of calibration services, we offer NATA
endorsed reports or non-NATA endorsed calibration documentation depending
on your equipment requirements. Ask about our range of booking options, or
whether our Mobile Calibration Lab (MCL) can be of benefit to you.
1300 790 480
info@trvms.com.au
www.trvms.com.au
TC0256
Agilent’s Electronic Measurement Group,
including its 9,500 employees and 12,000
products, is now Keysight Technologies.
Learn more at www.keysight.com
Australia
Malaysia
TechRentals New Zealand*
1800 632 652
www.techrentals.com.au
603 5614 1135
www.techrentals.com.my
0800 832 473
www.techrentals.co.nz
*Distributor of TechRentals Australia
TR1216