System x3850 X5 Lenovo Press Product Guide The x3850 X5 server is the fifth generation of the Enterprise X-Architecture, delivering innovation with enhanced reliability and availability features to enable optimal performance for databases, enterprise applications, and virtualized environments. Environments that run around the clock to supply information world-wide require dependable servers with features that can tolerate a component failure without total shutdown. The x3850 X5 server packs numerous fault-tolerant and high-availability features into a high-density, rack-optimized package that helps to significantly reduce the space needed to support massive network computing operations. A single x3850 X5 supports up to four of the new Intel Xeon E7 high-performance 10-core processors and up to 3 TB of memory. Two x3850 X5 servers can be connected together to form a single-system image with up to eight processors and up to 6 TB of RAM. This processing capacity is ideal for large-scale database or virtualization requirements. Figure 1 shows the System x3850 X5. Figure 1. The System x3850 X5 Did you know The x3850 X5 is an ideal server for enterprise database and virtualization workloads. The x3850 X5 currently holds the #1 scores in five industry-standard benchmarks. This includes a four-socket TPC-C (database benchmark) result of over 2.3 million transactions per minute (27% better than the closest HP result) and world record TPC-H (business intelligence) price performance result. System x3850 X5 1 Key features The x3850 X5 is a mission-critical 4U four-socket server, capable of expanding to up to 8 processor sockets and 6 TB of memory in 10U of rack space. It offering outstanding performance, and superior reliability and fault-tolerant memory characteristics. Lenovo eX5 technology represents the fifth generation of enterprise servers based on the same design principle that began with in 1997: to offer systems that are expandable, offer “big iron” reliability, availability, and serviceability (RAS) features, with extremely competitive price/performance on an Intel Xeon processor-based system. Scalability and performance The x3850 X5 offers numerous features to boost performance, improve scalability, and reduce costs: The x3850 X5 supports up to four high-performance Intel Xeon E7 family allowing you to upgrade as business needs require. Scalable to eight processors by connecting two x3850 X5 servers together to form a single system image. Each x3850 X5 scalable to 2 TB of memory internally or 3 TB of memory with the addition of the MAX5 V2 memory expansion unit. With two x3850 X5 servers each with MAX5 units, the total available system memory is up to 6 TB. Supports the Intel Xeon E7-2800, E7-4800 and E7-8800 families of high performance processors, up to 10 cores each, offering superior system performance Intel Turbo Boost Technology dynamically turns off unused processor cores and increases the clock speed of the cores in use, by up to three model frequencies. For example, with 7-10 cores active, a 2.4 GHz E7-2870 10-core processor can run the cores at up to 2.53 GHz. With 5-6 cores active, it can run those cores at 2.67 GHz; with only 1-4 cores active, it can run those cores at 2.8 GHz Each processor includes two integrated memory controllers, to reduce memory bottlenecks and improve performance. Memory access is at up to 1066 MHz frequency, depending on the processor model and memory used. The MAX5 V2 adds an additional four memory controllers for a total of eight memory controllers to maximize memory parallelism and performance. In processors implementing Hyper-Threading technology, each core has two threads capable of running an independent process. Thus, an 8-core processor can run 16 threads concurrently. Intel’s Virtualization Technology (VT) integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads. Intel QuickPath Interconnect (QPI) technology for processor-to-processor connectivity and Intel Scalable Memory Interconnect (SMI) processor-to-memory connectivity: Intel QPI link topology at up to 6.4 Gbps with four QPI links per CPU Intel SMI link topology at up to 6.4 Gbps with four SMI links per CPU Up to 64 DIMM sockets in the server (eight per memory card), plus an additional 32 DIMMs with an optional 1U MAX5 V2 memory expansion unit, for a total of 96 DIMM sockets. With two x3850 X5 servers each with MAX5 units, the total number of DIMM sockets is 192. The use of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs) can significantly improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD. System x3850 X5 2 Up to 24 1.8-inch SSD bays, or up to 16 2.5-inch bays together with the option of an optical drive, provide a flexible and scalable all-in-one platform to meet your increasing demands. Seven PCIe 2.0 slots for maximum I/O expandability Availability and serviceability The x3850 X5 provides many features to simplify serviceability and increase system uptime: Support for machine check architecture (MCA) recovery, a feature of the Intel Xeon processor E7 family, which enables the handling of system errors that otherwise require the operating system to be halted. SAP HANA is one of the first application which leverages the MCA recovery to handle system errors in order to prevent the application from being terminated in case of a system error. Extensive memory protection with Chipkill, and, with DIMMs containing x4 DRAM modules, Redundant Bit Steering (RBS) (also known as Double Device Data Correction or DDDC) is also supported . The combination of Chipkill and RBS provides very robust memory protection that sustains to two sequential memory DRAM chip failures without affecting overall system performance. Redundant CPU-to-I/O hub interconnect links provide ability to self-recover from CPU failure. If primary CPU fails then eX5 systems can use the second CPU to boot the OS as they still have access to the integrated I/O devices because of redundant links between CPUs and I/O hubs. Single image 8-way systems consisting of two interconnected 4-way nodes provide self-healing capabilities in case of single node failure. Two independent nodes form a resilient 8-way configuration. In case of single node failure the system can be restarted in degraded mode thus eliminating unexpected downtime that requires service specialist to recover. Memory mirroring and memory rank sparing for redundancy in the event of a non-correctable memory failure. Hot-swap drives, supporting RAID redundancy for data protection and greater system uptime. Two 1975 W hot-swap power supplies and five fans (three hot-swap, two integrated into the power supplies). The power source independent light path diagnostics panel and individual light path LEDs quickly lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability. Predictive Failure Analysis (PFA) detects when system components (processors, VRMs, memory, HDDs, fans, and power supplies) operate outside of standard thresholds and generates proactive alerts in advance of a possible failure, therefore increasing uptime. Solid-state drives (SSDs) offer significantly better reliability than traditional mechanical HDDs for greater uptime. Built-in Integrated Management Module (IMM) continuously monitors system parameters, triggers alerts, and performs recovering actions in case of failures to minimize downtime. Built-in diagnostics, using Dynamic Systems Analysis (DSA) Preboot, speed up troubleshooting tasks to reduce service time. Three-year customer-replaceable unit and on-site limited warranty, 9x5 next business day. Optional service upgrades are available. System x3850 X5 3 Manageability and security Powerful systems management features simplify local and remote management of the x3850 X5: The server includes an Integrated Management Module (IMM) to monitor server availability and perform remote management. Integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling. Integrated Trusted Platform Module (TPM) 1.2 support enables advanced cryptographic functionality, such as digital signatures and remote attestation. IBM Systems Director is included for proactive systems management. It offers comprehensive systems management tools that help to increase uptime, reduce costs, and improve productivity through advanced server management capabilities. Energy efficiency The x3850 X5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment: Energy-efficient planar components help lower operational costs. Support for one or two or four highly efficient 675 W ac power supplies allows for efficient use and scalability to meet the power requirements of the installed components. Intel Xeon processor E5-2600 product family offers significantly better performance over the previous generation while fitting into the same thermal design power (TDP) limits. Low-voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments. Low-voltage 1.35 V DDR3 memory RDIMMs consume 15% less energy compared to 1.5 V DDR3 RDIMMs. Solid state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs. The server uses hexagonal ventilation holes, which is a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system. IBM Systems Director Active Energy Manager™ provides advanced data center power notification and management to help achieve lower heat output and reduced cooling needs. System x3850 X5 4 Locations of key components Figure 2 shows the front of the server with the front bezel removed. Figure 2. Front view of the System x3850 X5 Figure 3 shows the rear of the server. Figure 3. Rear view of the System x3850 X5 System x3850 X5 5 Figure 4 shows the locations of key components inside the server. Figure 4. Inside view of the System x3850 X5 The x3850 X5 supports the addition of the MAX5 memory expansion unit. This 1U device is cabled directly to the server and provides an additional 512 GB of memory capacity for applications that can benefit from the extra RAM. Figure 5 shows the MAX5 optional memory expansion unit. Figure 5. Inside view of the MAX5 optional memory expansion unit for the System x3850 X5 System x3850 X5 6 Standard specifications The following table lists the standard specifications. Table 1. Standard specifications (Part 1) Components Specification Form factor/height Rack/4U per chassis; MAX5 adds 1U. Scalability Machine type 7143 can scale as follows: One server (4U rack-mounted complex) One server with MAX5 memory expansion unit (5U rack-mounted complex) Two servers with two MAX5 memory expansion units (10U rack-mounted complex) Processor type Machine type 7143: Intel Xeon E7-8800 and E7-4800 families, up to 10 cores. Number of processors Most models: 2 standard (some 4 standard); 4 maximum. Cache (max) Up to 30 MB L3 cache Memory DIMM sockets Up to eight memory cards, each with eight DIMM sockets (64 DIMM sockets total). MAX5 adds 32 DIMM sockets. Memory maximums 2.0 TB using 32 GB DIMMs. Up to 3.0 TB with the addition of MAX5. With two x3850 X5 servers and two MAX5 units, total capacity up to 6.0 TB Expansion slots Eight slots total: Seven PCIe 2.0 slots (one used by 10 Gb Ethernet card, if included). One PCIe 2.0 slot for supported RAID card. Disk bays Eight 2.5" hot-swap SAS or sixteen 1.8" solid-state drives (SSD). Maximum internal storage Using NL SAS HDDs: 8 TB per chassis with eight 1 TB drives Using 2. 5-inch SSDs: 12.8 TB per chassis with eight 1.6 TB drives Using eXFlash solid-state drives: 8 TB per chassis with 16x 512 GB SSDs Network interface Two 1 Gb Ethernet ports. Broadcom 5709C controller. Emulex 10Gb Virtual Fabric Adapter standard on most models with two 10 Gb Ethernet ports Power supply (std/max) Up to two hot-swap redundant 1975 W power supplies Hot-swap components Power supplies, fans, hard disk drives, and solid-state-drives. RAID support 7143: Integrated RAID-0, RAID-1 with ServeRAID M1015 in dedicated PCIe slot Optional RAID-5, 6, 10, 50, 60 External ports Rear: Four scalability ports , one Ethernet for systems management, one serial port, four USB 2.0, one VGA, two Gb Ethernet Front: Two USB 2.0 Internal: One USB 2.0 port for Embedded Hypervisor Systems management Alert on LAN 2, Automatic Server Restart, IBM Systems Director, ServerGuide, Integrated Management Module (IMM), light path diagnostics (independently powered), Predictive Failure Analysis on hard disk drives, processors, VRMs, fans and memory, Wake on LAN, Dynamic System Analysis, QPI Faildown. Operating systems supported Microsoft® Windows Server® 2008 (Standard, Enterprise and Data Center Editions 64-bit), 64-bit Red Hat Enterprise Linux®, 64-bit SUSE Enterprise Linux, (Server and Advanced Server), VMware vSphere Hypervisor System x3850 X5 7 Table 1. Standard specifications (Part 2) Components Specification Limited warranty Three-year customer-replaceable unit and onsite limited warranty. Dimensions Width: 440 mm (17.3 inches), depth: 712 mm (28.0 inches), height: 173 mm (6.8 inches) or 4 rack units (4U) Weight Minimum configuration: 35.4 kg (78 lb), maximum configuration: 49.9 kg (110 lb) The x3850 X5 servers are shipped with the following items: Rack rails and hardware Cable management hardware Country kit carton Two 2.8 m 220 V intra-rack cables On/off switch cover Documentation CD System x3850 X5 8 Standard models The following table lists the standard models. Table 2. Standard models - Machine type 7143 (Intel Xeon E7-4800 and E7-8800 series processors) Model 7143- Intel Xeon CPUs (4 max) (quantity, model, core speed, cores, L3 cache, memory speed) Scale without MAX5‡ Scale with MAX5‡ MAX5 Memory (cards)* RAID Bays (std/max) (No disks) 10G Std Std PS B1x 2x E7-4807 6C 1.86GHz 18MB 800 No Yes Opt 2x4GB (1) Opt 0 / 8 (2.5") Opt 1 B2x 2x E7-4820 8C 2.00GHz 18MB 1066 No Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 B3x 2x E7-4830 8C 2.13GHz 24MB 1066 No Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 B5x 2x E7-4850 10C 2.00GHz 24MB 1066 No Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 B6x 2x E7-4860 10C 2.26GHz 24MB 1066 No Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 B7x 2x E7-4870 10C 2.40GHz 30MB 1066 No Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 C1x 2x E7-8850 10C 2.00GHz 24MB 1066 Yes Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 C2x 2x E7-8860 10C 2.26GHz 24MB 1066 Yes Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 C3x 2x E7-8870 10C 2.40GHz 30MB 1066 Yes Yes Opt 4x4GB (2) M1015 4 / 8 (2.5") Std 2 ‡ Columns indicate whether the server can scale to two nodes without a MAX5 attached and with a MAX5 attached. * The number in brackets is the number of memory cards standard in each model. Up to eight cards are supported. Each holds up to eight DIMMs for a total of 64 DIMMs. The MAX5 adds 32 DIMM sockets for a total of 96 DIMMs. System x3850 X5 9 Workload-optimized models The following table lists the announced workload-optimized models. These are all named System x3950 X5 to distinguish them from base x3850 X5 models, even though the base hardware is the same. These are systems that are specially configured to meet the requirements of a particular software stack. Table 3. Workload-optimized models - Machine type 7143 (Intel Xeon E7-4800 and E7-8800 series processors) Model Intel Xeon CPUs (4 max)** MAX5 Memory= (cards)* Standard RAID Disk bays (std/max) Disks======= Network† DVD PS Database workload-optimized models 7143-D3x 4x E7-4860 10C 2.26GHz 24MB Opt 32x4GB (8 cards) 2x 6 Gb SSD HBA 16 / 16 (1.8" SSD) 16x 200GB 2x 1Gb + 2x 10Gb Opt 2 7143-D4x 4x E7-4860 10C 2.26GHz 24MB Opt 32x4GB (8 cards) 4x M5015 + perf keys 16 / 16 (1.8" SSD) 16x 200GB 2x 1Gb + 2x 10Gb Opt 2 SAP HANA workload-optimized models 7143-HAx 2x E7-8870 10C 2.40GHz 30MB NS§ 16x16GB (4 cards) 1x M5015 + battery 8/8 (2.5" HDD) 8x 900GB SAS 1x 1.2TB PCIe 6x 1Gb + 4x 10Gb Multi 2 7143-HBx 4x E7-8870 10C 2.40GHz 30MB NS§ 32x16GB (8 cards) 1x M5015 + battery 8/8 (2.5" HDD) 8x 900GB SAS 1x 1.2TB PCIe 6x 1Gb + 4x 10Gb Multi 2 7143-HCx‡ 4x E7-8870 10C 2.40GHz 30MB NS§ 32x16GB (8 cards) 1x M5015 + battery 8/8 (2.5" HDD) 8x 900GB SAS 1x 1.2TB PCIe 6x 1Gb + 4x 10Gb Opt 2 7143-HDx 4x E7-8870 10C 2.40GHz 30MB NS§ 32x32GB (8 cards) 1x M5015 + battery 8/8 (2.5" HDD) 8x 900GB SAS 1x 1.2TB PCIe 6x 1Gb + 4x 10Gb Multi 2 7143-HEx‡ 4x E7-8870 10C 2.40GHz 30MB NS§ 32x32GB (8 cards) 1x M5015 + battery 8/8 (2.5" HDD) 8x 900GB SAS 1x 1.2TB PCIe 6x 1Gb + 4x 10Gb Opt 2 Virtualization workload-optimized models 7143-F1x (ESX) 4x E7-4860 10C 2.26GHz 24MB Std (V2) 96x4GB (8 cards) 1x M1015 4/8 (2.5" HDD) Open 2x 1Gb + 2x 10Gb Opt 2 7143-F2x (RH) 4x E7-4860 10C 2.26GHz 24MB Std (V2) 96x4GB (8 cards) 1x M1015 4/8 (2.5" HDD) Open 2x 1Gb + 2x 10Gb Opt 2 7143-B9x (ESX) 4x E7-4807 6C 1.86GHz 18MB Std (V2) 96x4GB (8 cards) 1x M1015 4/8 (2.5" HDD) Open 2x 1Gb + 2x 10Gb Opt 2 ** Processor detail: Quantity, model, cores, core speed, memory speed, L3 cache. * The number in brackets is the number of memory cards standard in each model. Up to eight cards are supported. Each holds up to eight DIMMs for a total of 64 DIMMs. The MAX5 adds 32 DIMM sockets for a total of 96 DIMMs. † The H models include one Emulex 10GbE Integrated Virtual Fabric Adapter (with two 10GbE SW SFP+ Transceivers), one Emulex 10GbE Virtual Fabric Adapter II (with two 10GbE SW SFP+ Transceivers), and one Intel Ethernet Quad Port Server Adapter I340-T4 for a total of four 10Gb ports and six 1Gb ports. All F models include one Emulex 10GbE Integrated Virtual Fabric Adapter. D3x and D4x models include one Emulex 10GbE Integrated Virtual Fabric Adapter II. ‡ Models HCx and HEx include the QPI Scalability Kit (four cables), part number 46M0072. Use model HBx plus HCx or HDx plus HEx to form a 2-node scaled complex. § NS=Not supported. MAX5 is not currently certified for use with SAP HANA and is therefore not supported System x3850 X5 10 About these models: Models 7143-D3x, D4x: These models are designed for database applications and use solid state drives for the best I/O performance. Backplane connections for sixteen 1.8-inch solid state drives (SSD) are standard, as are sixteen 200 GB high-performance solid-state drives. Model D3x includes two SSD host bus adapters. Model D4x includes four ServeRAID M5015 RAID controllers with four ServeRAID M5000 Series Performance Accelerator Keys. Models 7143-HAx, HBx, HCx: These models are optimized to run the SAP High-Performance Analytic Appliance (HANA) solution. The x3950 X5 Workload Optimized Solution for SAP HANA is an integrated, ready-to-run, hardware-software offering, featuring the new SAP HANA software. Models HDx and HEx are specifically designed for SAP Business Suite, powered by SAP HANA (OLTP) workloads. Models HAx, HBx, HDx include a preload comprising SLES for SAP, IBM GPFS, and the SAP HANA software stack. HCx, HEx are add-on models designed to be connected to model HBx or HDx system respectively to form an eight-processor system. HCx and HEx include the four QPI cables necessary to join two systems together to form a two-node complex. HCx and HEx also include the additional GPFS software and SLES licenses to cover the extra four sockets, but do not include any preload because the are designed as an add-on to the HBx and HDx offerings respectively. All H models include either 256 GB, 512 GB or 1024 GB of RAM, SAS disk drives, and a high IOPS solid-state storage PCIe adapter. Model 7143-F1x, B9x: These models are designed for virtualization applications and include VMware ESXi 4.1 Update 1 on an integrated bootable USB memory key. The model comes standard with the MAX5 memory expansion unit and 384 GB of memory implemented using 4GB memory DIMMs (256 GB in the server and 128 GB in the MAX5). F1x is available world-wide and includes a MAX5 V2, 88Y6529. Model B9x is for China only and includes a MAX5 V2, 88Y6529. Model 7143-F2x: This model is designed for Open Virtualization and includes Red Hat Enterprise Linux with the Red Hat Enterprise Virtualization Hypervisor (Kernel-Based Virtual Machine, KVM). The software is not preloaded. The model comes standard with the MAX5 memory expansion unit and 384 GB of memory implemented using cost-effective 4GB memory DIMMs (256 GB in the server and 128 GB in the MAX5). Refer to the Standard Specifications section for information about standard features of the server. System x3850 X5 11 QPI wrap card In the x3850 X5, QPI links are used for interprocessor communication both in a single-node system and in a two-node system. They are also used to connect the system to a MAX5 memory expansion unit. In a single-node x3850 X5, the QPI links connect in a full mesh between all CPUs. To complete this mesh, the QPI wrap card is used. QPI wrap cards are installed in sockets where the scalability cables are installed. The QPI wrap cards are only for single-node configurations with three or four processors installed and only when a MAX5 unit is not installed. Two QPI wrap cards are needed. Table 4. QPI wrap card Part number Feature code Description Maximum supported 49Y4379 5104 x3850 X5 and x3950 X5 QPI wrap card kit (quantity 2) 1 pair QPI wrap cards are not necessary for any of the following configurations: Single-node configurations with two processors Any configurations with MAX5 memory expansion units Two-node configurations System x3850 X5 12 MAX5 The MAX5 memory expansion unit is a 1U device and has 32 DDR3 DIMM sockets, two 675-watt power supplies, and five 40 mm hot-swap speed-controlled fans. It provides added memory and multinode scaling support for the x3850 X5 server. Some models include the MAX5 standard, as listed in Tables 2 and 3. MAX5 options are listed in the following table. There are two MAX5 options available. MAX5 for System x®, part number 59Y6265 (also known as MAX5 V1) MAX5 V2 for System x, part number 88Y6529 Both x3850 X5 machine types (7143 and 7145) support both MAX5 options, provided the firmware is at least UEFI level G0E171T/A. When used with the x3850 X5 machine type 7143 (Intel Xeon E7-4800 and E7-8800 series processors), MAX5 V2 supports low-voltage (operating at 1.35V DIMMs). Note that some models and some processors do not support the MAX5. See the model table and the processor options table for details. The MAX5 V1 includes one power supply. The second power supply is optional (part 60Y0332) and provides redundancy. The MAX5 V2 includes two power supplies; no additional power supplies are needed or available. Table 5. MAX5 Part number Feature code Description Maximum supported 59Y6265 4199 MAX5 for System x 1 88Y6529 A19H MAX5 V2 for System x 1 60Y0332 4782 High Efficiency 675W Power Supply (MAX5 V1 only, 59Y6265) 1 59Y6267 4192 MAX5 to x3850 X5 Cable Kit (quantity of four cables) (Used to connect one server to one MAX5) 1 System x3850 X5 13 Two-node and MAX5 scaling The x3850 X5 supports the following scalable configurations: A single x3850 X5 server with four processor sockets. This configuration is sometimes referred to as a single-node server. A single x3850 X5 server with a single MAX5 memory expansion unit attached. This configuration is sometimes referred to as a memory-expanded server. Two x3850 X5 servers connected together to form a single-image eight-socket server. This configuration is sometimes referred to as a two-node server. Two x3850 X5 servers connected together to form a single-image eight-socket server with two MAX5 memory expansion units attached. This configuration is sometimes referred to as a two-node memory-expanded server. Only machine type 7143 supports this configuration. The following table lists the cable options needed when scaling. Note that not all processors and models support all of these configurations - see the Processor options section below for details. Table 6. Cables for two-node and MAX5 scaling Part number Feature code Description Maximum supported 59Y6267 4192 MAX5 to x3850 X5 Cable Kit (quantity of four cables) Used to connect one server to one MAX5 1 46M0072 5103 x3850 X5 and x3950 X5 QPI Scalability Kit (Quantity 4 cables) Used to connect two servers together without MAX5 units 1 59Y6271 4198 eX5 MAX5 2-Node EXA Scalability Kit (for machine type 7143 only) Used to connect two servers together when MAX5 units are also used 1 System x3850 X5 14 Processor options The x3850 X5 supports the processor options listed in the following table. The server supports up to four processors. The E7-8000 processors support native QPI scaling to two nodes without the need for a MAX5 memory expansion unit. All Intel Xeon E7 processors support two-node scaling with MAX5. Two-node scaling with MAX5 is supported with MAX5 V2 for System x (88Y6529) or MAX5 for System x (59Y6265). Table 7. Processor options - Machine type 7143 (Intel Xeon E7-4800 and E7-8800 series processors) Part number Intel Xeon processor description Can scale to two nodes without MAX5 Can scale to two nodes with MAX5* Models where used 69Y1889 E7-4807 6C 1.86GHz 18MB 800MHz 95W No Yes 7143-B1x 69Y1890 E7-4820 8C 2.00GHz 18MB 1066MHz 105W No Yes 7143-B2x 69Y1891 E7-4830 8C 2.13GHz 24MB 1066MHz 105W No Yes 7143-B3x 88Y5358 E7-4850 10C 2.00GHz 24MB 1066MHz 130W No Yes 7143-B5x, D1x 69Y1892 E7-4860 10C 2.26GHz 24MB 1066MHz 130W No Yes 7143-B6x, D2x 69Y1893 E7-4870 10C 2.40GHz 30MB 1066MHz 130W No Yes 7143-B7x 69Y1896 E7-8830 8C 2.13GHz 24MB 1066MHz 105W Yes Yes - 69Y1894 E7-8837 8C 2.67GHz 24MB 1066MHz 130W Yes Yes - 88Y5357 E7-8850 10C 2.00GHz 24MB 1066MHz 130W Yes Yes 7143-C1x 69Y1898 E7-8860 10C 2.26GHz 24MB 1066MHz 130W Yes Yes 7143-C2x 69Y1897 E7-8867L 10C 2.13GHz 30MB 1066MHz 105W Yes Yes - 69Y1899 E7-8870 10C 2.40GHz 30MB 1066MHz 130W Yes All Hxx models Yes * Supports MAX5 V2 for System x (88Y6529) or MAX5 for System x (59Y6265). System x3850 X5 15 Memory options Lenovo DDR3 memory is compatibility tested and tuned for optimal System x performance and throughput. Lenovo memory specifications are integrated into the light path diagnostics for immediate system performance feedback and optimum system uptime. From a service and support standpoint, Lenovo memory automatically assumes the system warranty, and Lenovo provides service and support worldwide. The System x3850 X5 supports DDR3 memory. Memory is installed in memory cards. The server supports eight memory cards, and each card holds eight DIMMs. Two memory cards are connected to each processor. As a result, all eight memory cards are usable only when all four processors are installed. Adding a MAX5 memory expansion unit to the server offers an additional 32 DIMM slots for a total of 96 DIMM slots per node. The following table lists the memory options that are supported in the server and MAX5 (either MAX5 V2 or MAX5). Notes: In the MAX5 memory expansion unit, do not mix DIMMs with x4 technology (DIMMs with DRAMs that are organized with 4 data lanes, as indicated by "x4" in the description) with DIMMs with x8 technology (DIMMs with DRAMs that are organized with 8 data lanes). In the server, you can mix DIMMs with x4 and x8 technology. Table 8. Memory options - x3850 X5 machine type 7143 (Intel Xeon E7 series processors) Part number x3850 X5 feature code Description Where used 69Y1888 A14D x3850 X5 and x3950 X5 Memory Expansion Card (7143 only) All 7143 models 44T1592 1712 2GB (1x2GB, 1Rx8, 1.5V) PC3-10600 CL9 ECC DDR3 1333MHz - 49Y1407 8942 4GB (1x4GB, 2Rx8, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz - 44T1599 1713 4GB (1x4GB, Dual Rankx8) PC3-10600 CL9 ECC DDR3 1333MHz All other models 49Y1399 A14E 8GB (1x8GB, 4Rx8, 1.35V) PC3L-8500 CL7 ECC DDR3 1066MHz - 46C7482 1706 8GB (1x8GB, Quad Rankx8) PC3-8500 CL7 ECC DDR3 1066MHz - 49Y1400 8939 16GB (1x16GB, 4Rx4, 1.35V) PC3L-8500 CL7 ECC DDR3 1066MHz All Hxx models 46C7483 1707 16GB (1x16GB, 4Rx4, 1.5V) PC3-8500 CL7 ECC DDR3 1066MHz - 49Y1563 A1QT 16 GB (1x16GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333 MHz LP RDIMM - 90Y3101 A1CP 32GB (1x32GB, 4Rx4, 1.35V) PC3L-8500 CL7 ECC DDR3 1066MHz - System x3850 X5 16 Table 9. Memory options - MAX5 V2, 88Y6529 Part number MAX5 V2 feature code Description 44T1592 2429 2GB MAX5 1x2GB 1Rx8 1.5V PC3-10600 CL9 ECC DDR3 1333MHz LP RDIMM 49Y1407 A1MH 4GB MAX5 (1x4GB, 2Gb, 2Rx8, 1.35V) PC3L-10600R-999 LP ECC RDIMM 44T1599 2431 4GB MAX5 1x4GB DualRankx8 PC310600 CL9 ECC DDR3 1333MHz LP RDIMM 46C7482 2432 8GB MAX5 1x8GB QuadRankx8 PC3-8500 CL7 ECC DDR3 1066MHz LP RDIMM 49Y1399 A1N7 8GB MAX5 1x8GB, 4Rx8, 1.35V PC3L-8500 CL7 ECC DDR3 1066MHz LP RDIMM 46C7483 2433 16GB MAX5 1x16G QuadRankx4 PC3-8500 CL7 ECC DDR3 1066MHz LP RDIMM None A3E1 16GB MAX5 1x16GB 2Rx4 1.35V PC3L-10600 CL9 ECC DDR3 1333MHz LP RDIMM 49Y1400 A1N8 16GB MAX5 1x16GB 4Rx4 1.35V PC3L-8500 CL7 ECC DDR3 1066MHz LP RDIMM 90Y3101 A1R2 32GB MAX5 (4GB, 4Rx4, 1.35V) PC3L-8500 DDR3-1066MHz LP RDIMM Table 10. Memory options - MAX5, 59Y6265 Part number MAX5 feature code Description 44T1592 2429 2GB MAX5 1x2GB 1Rx8 1.5V PC3-10600 CL9 ECC DDR3 1333MHz LP RDIMM 44T1599 2431 4GB MAX5 1x4GB DualRankx8 PC310600 CL9 ECC DDR3 1333MHz LP RDIMM 46C7482 2432 8GB MAX5 1x8GB QuadRankx8 PC3-8500 CL7 ECC DDR3 1066MHz LP RDIMM 46C7483 2433 16GB MAX5 1x16G QuadRankx4 PC3-8500 CL7 ECC DDR3 1066MHz LP RDIMM The following memory protection technologies are supported: ECC ChipKill Memory Mirroring Memory Sparing Redundant Bit Steering (MAX5, or servers with E7 processors only, x4 DIMMs only) System x3850 X5 17 Internal storage The server supports either up to eight 2.5" drives or up to 16 1.8" drives internally. The number of drives that can be inserted depends on the backplanes that are installed. Backplane options are listed in the following table. The backplanes that are standard in each model are listed in Table 2. Table 11. Drive backplane options Part number Feature code Name Maximum supported 59Y6213 4191 eXFlash 8x 1.8-inch HS SAS SSD Backplane Supports eight 1.8" drives (includes two SAS cables) 2 59Y6135 3873 2.5" Hot Swap SAS Hard Disk Drive Backplane Supports four 2.5-inch drives (includes one SAS cable) 2 Internal drive options The following table lists the hard drive options available for internal storage. Table 12. Disk drive options for internal disk storage (Part 1) Part number Feature code Description Maximum supported 2.5-inch 15K SAS hot-swap HDDs 42D0677 5536 146GB 15K 6Gbps SAS 2.5" SFF Slim-HS HDD 8 90Y8926 A2XB 146GB 15K 6Gbps SAS 2.5" SFF G2HS HDD 8 81Y9670 A283 300GB 15K 6Gbps SAS 2.5" SFF HS HDD 8 00AJ300 A4VB 600GB 15K 6Gbps SAS 2.5'' G2HS HDD 8 2.5-inch 15K SAS hot-swap SEDs 44W2294 5412 146GB 15K 6Gbps SAS 2.5" SFF Slim-HS SED 8 90Y8944 A2ZK 146GB 15K 6Gbps SAS 2.5" SFF G2HS SED 8 2.5-inch 10K SAS hot-swap HDDs 42D0637 5599 300GB 10K 6Gbps SAS 2.5" SFF Slim-HS HDD 8 90Y8877 A2XC 300GB 10K 6Gbps SAS 2.5" SFF G2HS HDD 8 49Y2003 5433 600GB 10K 6Gbps SAS 2.5" SFF Slim-HS HDD 8 90Y8872 A2XD 600GB 10K 6Gbps SAS 2.5" SFF G2HS HDD 8 81Y9650 A282 900GB 10K 6Gbps SAS 2.5" SFF HS HDD 8 00AD075 A48S 1.2TB 10K 6Gbps SAS 2.5'' G2HS HDD 8 System x3850 X5 18 Table 12. Disk drive options for internal disk storage (Part 2) Part number Feature code Description Maximum supported 2.5-inch 10K SAS hot-swap SEDs 44W2264 5413 300GB 10K 6Gbps SAS 2.5" SFF Slim-HS SED 8 90Y8913 A2XF 300GB 10K 6Gbps SAS 2.5" SFF G2HS SED 8 90Y8908 A3EF 600GB 10K 6Gbps SAS 2.5" SFF G2HS SED 8 81Y9662 A3EG 900GB 10K 6Gbps SAS 2.5" SFF G2HS SED 8 00AD085 A48T 1.2TB 10K 6Gbps SAS 2.5'' G2HS SED 8 1.8-inch solid state drives (SSDs) - Enterprise 41Y8366 A4FS S3700 200GB SATA 1.8" MLC Enterprise SSD 16 41Y8371 A4FT S3700 400GB SATA 1.8" MLC Enterprise SSD 16 00W1120 A3HQ 100GB SATA 1.8" MLC Enterprise SSD 16 49Y6119 A3AN 200GB SATA 1.8" MLC Enterprise SSD 16 49Y6124 A3AP 400GB SATA 1.8" MLC Enterprise SSD 16 1.8-inch solid state drives (SSDs) - Enterprise Value 00AJ335 A56V 120GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ340 A56W 240GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ345 A56X 480GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ350 A56Y 800GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ040 A4KV S3500 80GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ045 A4KW S3500 240GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ050 A4KX S3500 400GB SATA 1.8" MLC Enterprise Value SSD 16 00AJ455 A58U S3500 800GB SATA 1.8" MLC Enterprise Value SSD 16 2.5-inch solid state drives (SSDs) - Enterprise 41Y8331 A4FL S3700 200GB SATA 2.5" MLC HS Enterprise SSD 8 41Y8336 A4FN S3700 400GB SATA 2.5" MLC HS Enterprise SSD 8 41Y8341 A4FQ S3700 800GB SATA 2.5" MLC HS Enterprise SSD 8 00W1125 A3HR 100GB SATA 2.5" MLC HS Enterprise SSD 8 49Y6134 A3EY 400GB SAS 2.5" MLC HS Enterprise SSD 8 49Y6139 A3F0 800GB SAS 2.5" MLC HS Enterprise SSD 8 49Y6195 A4GH 1.6TB SAS 2.5" MLC HS Enterprise SSD 8 System x3850 X5 19 Table 12. Disk drive options for internal disk storage (Part 3) Part number Feature code Description Maximum supported 2.5-inch solid state drives (SSDs) - Enterprise Value 00AJ355 A56Z 120GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ360 A570 240GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ365 A571 480GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ370 A572 800GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ000 A4KM S3500 120GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ005 A4KN S3500 240GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ010 A4KP S3500 480GB SATA 2.5" MLC HS Enterprise Value SSD 8 00AJ015 A4KQ S3500 800GB SATA 2.5" MLC HS Enterprise Value SSD 8 00FN268 A5U4 S3500 1.6TB SATA 2.5" MLC HS Enterprise Value SSD 8 2.5-inch SAS-SSD hybrid drives 00AD102 A4G7 600GB 10K 6Gbps SAS 2.5'' G2HS Hybrid 8 2.5-inch NL SAS hot-swap HDDs 81Y9726 A1NZ 500GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD 8 90Y8953 A2XE 500GB 7.2K 6Gbps NL SAS 2.5" SFF G2HS HDD 8 81Y9690 A1P3 1TB 7.2K 6Gbps NL SAS 2.5" SFF HS HDD 8 2.5-inch NL SATA hot-swap HDDs 81Y9722 A1NX 250GB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD 8 42D0752 5407 500GB 7200 NL SATA 2.5" SFF Slim-HS HDD 8 81Y9730 A1AV 1TB 7.2K 6Gbps NL SATA 2.5" SFF HS HDD 8 System x3850 X5 20 Controllers for internal storage The following table lists the RAID controllers, SAS HBAs and additional options used for internal disk storage of x3850 X5 server. Table 13. RAID controllers and SAS HBAs for internal storage Part number Feature code Description Maximum supported 90Y4304 A2NF ServeRAID M5016 SAS/SATA Controller for System x 2 46M0916 3877 ServeRAID M5014 SAS/SATA Controller 4 46M0829 0093 ServeRAID M5015 SAS/SATA Controller 4 46M0831 0095 ServeRAID M1015 SAS/SATA Controller 1 46M0912 3876 6Gb Performance Optimized HBA 4 46C8988 A3MW N2115 SAS/SATA HBA for System x 4 46M0832 9749 ServeRAID M1000 Series Advance Feature Key 1 81Y4426 A10C ServeRAID M5000 Series Performance Accelerator Key† 4 46M0930 5106 ServeRAID M5000 Series Advance Feature Key† 4 46M0917 5744 ServeRAID M5000 Series Battery Assembly 4 88Y5874 A39Q ServeRAID M5016 Battery Tray 1 Adapters Adapter upgrades † Only one key is supported in each controller, either the Advance Feature Key or the Performance Accelerator Key. The ServeRAID M1015 SAS/SATA Controller has the following specifications: Two Mini-SAS internal connectors Supports RAID levels 0, 1, and 10 Supports RAID levels 5 and 50 with optional ServeRAID M1000 Series Advanced Feature Key 6 Gbps throughput per port Based on the LSI SAS2008 6 Gbps RAID on Chip (ROC) controller PCI Express 2.0 x8 host interface Configurable stripe size up to 64 KB The ServeRAID M5014 SAS/SATA Controller has the following specifications: Two Mini-SAS internal connectors Supports RAID levels 0, 1, 5, 10, and 50 Supports RAID 6 and 60 with the optional M5000 Advanced Feature Key Performance optimization for SSD drives with optional M5000 Series Performance Accelerator Key 6 Gbps throughput per port PCI Express 2.0 x8 host interface Based on the LSI SAS2108 6 Gbps ROC controller 256 MB of onboard cache Optional Intelligent Li-Ion-based battery backup unit with the ServeRAID M5000 Series Battery Kit System x3850 X5 21 The ServeRAID M5015 SAS/SATA Controller has the following specifications: Two Mini-SAS internal connectors Supports RAID levels 0, 1, 5, 10, and 50 Supports RAID 6 and 60 with the optional M5000 Advanced Feature Key Performance optimization for SSD drives with optional M5000 Series Performance Accelerator Key 6 Gbps throughput per port PCI Express 2.0 x8 host interface Based on the LSI SAS2108 6 Gbps ROC controller 512 MB of onboard cache Standard Intelligent Li-Ion-based battery backup unit with up to 48 hours of data retention The ServeRAID M5016 adapter card has the following specifications: Two Mini-SAS internal connectors (SFF-8087) 6 Gbps throughput per port 800 MHz dual-core PowerPC® processor with LSI SAS2208 6 Gbps RAID on Chip (ROC) controller PCI Express x8 Gen 2 host interface 1 GB of onboard data cache (DDR3 running at 1333 MHz) CacheVault flash power module to protect data in cache in case of critical power or server failure Supports RAID levels 0, 1, 5, 6, 10, 50, and 60 Supports up to 64 logical volumes Supports LUN sizes up to 64 TB Configurable stripe size up to 1 MB The ServeRAID M5016 Battery Tray, 90Y4304, is used to house the M5016 power module remotely from the controller. The tray replaces the existing tray supplied with the server and supports up to two power modules. Only one ServeRAID M5016 Battery Tray can be installed in the x3850 X5. For more information, see the list of Lenovo Press Product Guides in the RAID adapters category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=raid Internal tape drives The server does not support an internal tape drive option. System x3850 X5 22 Optical drives The server supports the optical drive options listed in the following table. Table 14. Optical drives Part number Feature code Description Maximum supported Standard models where used 46M0901 4161 UltraSlim Enhanced SATA DVD-ROM 1 - 46M0902 4163 UltraSlim Enhanced SATA Multi-Burner 1 7143-HAx, HBx UltraSlim Enhanced SATA DVD-ROM (part number 46M0901) supports the following media and speeds for reading: CD-ROM 24X CD-DA (DAE) 20X CD-R 24X CD-RW 24X DVD-ROM (single layer) 8X DVD-ROM (dual layer) 8X DVD-R (4.7 GB) 6X DVD-R DL 4X DVD+R 6X DVD+R DL 4X DVD-RW (4.7 GB) 4X DVD+RW 4X DVD-RAM (4.7/9.4 GB) 4X UltraSlim Enhanced SATA Multi-Burner (part number 46M0902) supports the same media and speeds for reading as DVD-ROM (46M0901). In addition, this drive supports the following media and speeds for writing: CD-R 24X CD-RW 4X High Speed CD-RW 10X Ultra Speed CD-RW 16X Ultra Speed Plus CD-RW 16X DVD-R 8X DVD-R DL 6X DVD+R 8X DVD+R DL 6X DVD-RW 6X DVD+RW 8X DVD-RAM 5X System x3850 X5 23 I/O expansion options The server offers the following PCI Express 2.0 slots. None are hot-swap. Slot 1: PCI Express 2.0 x16, full length, full height Slot 2: PCI Express 2.0 x4 (x8 mechanical), full length, full height Slot 3: PCI Express 2.0 x8, full length, full height Slot 4: PCI Express 2.0 x8, full length, full height Slot 5: PCI Express 2.0 x8, half length, full height Slot 6: PCI Express 2.0 x8, half length, full height Slot 7: PCI Express 2.0 x8, half length, full height (used by the Emulex 10Gb Ethernet Adapter) The server has an additional PCI Express slot dedicated to the BR10i RAID controller if installed. Note: The use of slots 1 - 4 requires that a second processor be installed. Network adapters x3850 X5 offers two integrated Gigabit Ethernet ports, based on the Broadcom BCM5709C controller. Most models also have an Emulex 10GbE Integrated Virtual Fabric Adapter II for System x (feature A148) installed as standard in slot 7. See Table 2 for specifics. This adapter is functionally identical to the Emulex 10Gb Virtual Fabric Adapter II for System x, 49Y7950. The difference is that the integrated adapter has a longer edge connector, meaning that the card can only be installed in this server. For technical details about this card, see the Lenovo Press Product Guide Emulex 10GbE Virtual Fabric Adapter II and III family for System x, TIPS0844, available at http://www.redbooks.ibm.com/abstracts/tips0844.html. System x3850 X5 24 The following table lists additional supported network adapters. Table 15. Network adapters (Part 1) Part number Feature code Description Maximum supported Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x 7 40 Gb Ethernet 00D9550 A3PN 10 Gb Ethernet 44T1370 A5GZ Broadcom NetXtreme 2x10GbE BaseT Adapter for System x 7 94Y5180 A4Z6 Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter for System x 7 49Y7910 A18Y Broadcom NetXtreme II Dual Port 10GBaseT Adapter for System x 7 None* A148 Emulex 10GbE Integrated Virtual Fabric Adapter II for System x 1 49Y7950 A18Z Emulex 10GbE Virtual Fabric Adapter II for System x 7 95Y3751 A348 Emulex Dual Port VFAII Adapter & FCoE/iSCSI License for System x 7 00JY830 A5UU Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW for System x 7 None* AS3M Emulex VFA5 2x10 GbE SFP+ Integrated Adapter for System x 7 00JY820 A5UT Emulex VFA5 2x10 GbE SFP+ PCIe Adapter for System x 7 00JY824 A5UV Emulex VFA5 FCoE/iSCSI SW for PCIe Adapter for System x (FoD) (Features on Demand upgrade for 00JY820 and feature AS3M) 7 49Y7960 A2EC Intel X520 Dual Port 10GbE SFP+ Adapter for System x 7 49Y7970 A2ED Intel X540-T2 Dual Port 10GBaseT Adapter for System x 7 81Y3520 AS73 Intel X710 2x10GbE SFP+ Adapter for System x 7 81Y9990 A1M4 Mellanox ConnectX-2 Dual Port 10GbE Adapter for System x 7 00D9690 A3PM Mellanox ConnectX-3 10 GbE Adapter for System x 7 42C1750 2975 PRO/1000 PF Server Adapter 7 42C1800 5751 QLogic 10Gb CNA for System x 7 47C9952 A47H Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter for System x 4 47C9960 A47J Solarflare SFN6122F LL Dual Port 10GbE SFP+ Adapter for System x 4 * The Emulex integrated adapters are either included in standard models or available via CTO only System x3850 X5 25 Table 15. Network adapters (Part 2) Part number Feature code Description Maximum supported 1 Gb Ethernet 90Y9370 A2V4 Broadcom NetXtreme I Dual Port GbE Adapter for System x 7 90Y9352 A2V3 Broadcom NetXtreme I Quad Port GbE Adapter for System x 7 49Y4230 5767 Intel Ethernet Dual Port Server Adapter I340-T2 for System x 7 49Y4240 5768 Intel Ethernet Quad Port Server Adapter I340-T4 for System x 7 00AG500 A56K Intel I350-F1 1xGbE Fiber Adapter for System x 7 00AG510 A56L Intel I350-T2 2xGbE BaseT Adapter for System x 7 00AG520 A56M Intel I350-T4 4xGbE BaseT Adapter for System x 7 42C1780 2995 NetXtreme II 1000 Express Dual Port Ethernet Adapter 7 95Y3750 A2MY Mellanox ConnectX-2 Dual-port QSFP QDR IB Adapter for System x 1 00D9550 A3PN Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x 7 InfiniBand * The Emulex integrated adapters are either included in standard models or available via CTO only For more information, see the list of Lenovo Press Product Guides in the Ethernet and IB adapters category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=networkadapters System x3850 X5 26 Storage host bus adapters The following table lists storage HBAs supported by the x3850 X5 server. Table 16. Storage adapters Part number Feature code Description Maximum supported 16 Gb Fibre Channel 81Y1675 A2XV Brocade 16Gb FC Dual-port HBA for System x 7 81Y1668 A2XU Brocade 16Gb FC Single-port HBA for System x 7 81Y1662 A2W6 Emulex 16Gb FC Dual-port HBA for System x 7 81Y1655 A2W5 Emulex 16Gb FC Single-port HBA for System x 7 00Y3341 A3KX QLogic 16Gb FC Dual-port HBA for System x 7 00Y3337 A3KW QLogic 16Gb FC Single-port HBA for System x 7 8 Gb Fibre Channel 46M6050 3591 Brocade 8Gb FC Dual-port HBA for System x 7 46M6049 3589 Brocade 8Gb FC Single-port HBA for System x 7 42D0494 3581 Emulex 8Gb FC Dual-port HBA for System x 7 42D0485 3580 Emulex 8Gb FC Single-port HBA for System x 7 42D0510 3579 QLogic 8Gb FC Dual-port HBA for System x 7 42D0501 3578 QLogic 8Gb FC Single-port HBA for System x 7 46M0907 5982 6Gb SAS HBA 7 46C9010 A3MV N2125 SAS/SATA HBA for System x 7 SAS For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=hba System x3850 X5 27 PCIe SSD adapters The server supports the High IOPS SSD adapters listed in the following table. Table 17. SSD adapters Part number Feature code Description Maximum supported 90Y4377 A3DY 1.2TB High IOPS MLC Mono Adapter 7 90Y4397 A3DZ 2.4TB High IOPS MLC Duo Adapter 2 46C9078 A3J3 365GB High IOPS MLC Mono Adapter 7 46C9081 A3J4 785GB High IOPS MLC Mono Adapter 7 * These modular adapters are not available via CTO or Special build. The adapter cannot be shipped installed and instead must be shipped in its option box and configured at the final installation location. For more information, see https://ibm.com/support/entry/myportal/docdisplay?lndocid=SERV-IOMA For more information, see the list of Lenovo Press Product Guides in the Internal Storage category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=internalstorage Power supplies The server supports up to two redundant hot-swap power supplies, providing N+N redundancy. Most standard models come with two power supplies (Table 2). The MAX5 power subsystem consists of two hot-pluggable 675 W power supplies, designed for N+N (fully redundant) hot-swap operation. The MAX5 V1 has one power supply standard and a second optional power supply for redundancy. See the MAX5 section for details. The MAX5 V2 has two power supplies installed. No further power supplies are needed or available. Table 18. Power supplies Part number Feature code Description Maximum supported 59Y6139 2111 1975 W Power Supply (x3850 X5) 2 (1 or 2 standard) 60Y0332 4782 High Efficiency 675W Power Supply For second power supply for MAX5 V1 1 (MAX5 V1 only) An AC power supply ships standard with one 2.8 m C13 - C14 power cord. System x3850 X5 28 Integrated virtualization The server supports VMware ESXi installed on a USB memory key. The key is installed in a USB socket inside the server. The following table lists the virtualization options. Table 19. Virtualization options Part number Feature code Description Maximum supported 41Y8298 A2G0 Blank USB Memory Key for VMware ESXi Downloads 1 41Y8296 A1NP USB Memory Key for VMware ESXi 4.1 Update 1 1 41Y8300 A2VC USB Memory Key for VMWare ESXi 5.0 1 41Y8307 A383 USB Memory Key for VMware ESXi 5.0 Update1 1 41Y8311 A2R3 USB Memory Key for VMWare ESXi 5.1 1 41Y8382 A4WZ USB Memory Key for VMware ESXi 5.1 Update 1 1 41Y8385 A584 USB Memory Key for VMWare ESXi 5.5 1 Remote management The server contains Integrated Management Module (IMM), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. The IMM also provides a virtual presence capability for remote server management capabilities. The IMM provides remote server management through industry-standard interfaces: Intelligent Platform Management Interface (IPMI) Version 2.0 Simple Network Management Protocol (SNMP) Version 3 Common Information Model (CIM) Web browser The server also supports virtual media and remote control features, which provide the following functions: Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz, regardless of the system state Remotely accessing the server using the keyboard and mouse from a remote client Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive Capture blue-screen errors System x3850 X5 29 Supported operating systems The server supports the following operating systems: Microsoft Windows Server 2008 HPC Edition Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008, Datacenter x64 Edition Microsoft Windows Server 2008, Enterprise x64 Edition Microsoft Windows Server 2008, Standard x64 Edition Microsoft Windows Server 2008, Web x64 Edition Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Microsoft Windows Small Business Server 2008 Premium Edition Microsoft Windows Small Business Server 2008 Standard Edition Red Hat Enterprise Linux 5 Server with Xen x64 Edition Red Hat Enterprise Linux 5 Server x64 Edition Red Hat Enterprise Linux 6 Server x64 Edition Red Hat Enterprise Linux 7 Red Hat Enterprise MRG 2.0 Realtime (x64) Solaris 10 Operating System SUSE LINUX Enterprise Server 10 for AMD64/EM64T SUSE LINUX Enterprise Server 10 with Xen for AMD64/EM64T SUSE LINUX Enterprise Server 11 for AMD64/EM64T SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T VMware ESX 4.1 VMware ESXi 4.1 VMware vSphere 5.0 (ESXi) VMware vSphere 5.1 (ESXi) VMware vSphere 5.5 (ESXi) See the ServerProven® website for the latest information about the specific versions and service levels supported and any other prerequisites: http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/nos/matrix.shtml System x3850 X5 30 Physical and electrical specifications Dimensions: Width: 440 mm (17.3 inches) Depth: 712 mm (28.0 inches) Height: 173 mm (6.8 inches) or 4 rack units (4U) Weight: Minimum configuration: 35.4 kg (78 lb) Maximum configuration: 49.9 kg (110 lb) Electrical: 100 to 127 (nominal) V ac; 50 or 60 Hz; System 20A (10A/PS) 200 to 208 (nominal) V ac; 50 or 60 Hz; System 10A 200 to 240 (nominal) V ac; 50 or 60 Hz; System 9A Minimum configuration: 0.20 kVA (one power supply) Minimum configuration: 0.26 kVA (two power supplies) Typical configuration: 1.12 kVA (two power supplies) Maximum configuration: 2.16 kVA (two power supplies) Btu output: Ship configuration (one power supply): 648 Btu/hr (190 watts) Ship configuration (two power supplies): 802 Btu/hr (235 watts) Typical configuration: 3,753 Btu/hr (1100 watts) Full configuration: 7,336 Btu/hr (2150 watts) Noise level: 6.3 bels Note: The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296. System x3850 X5 31 Warranty options The System x3850 X5 has a 3-year onsite warranty with 9x5/next-business-day terms. Lenovo offers the warranty service upgrades through ServicePacs®, discussed in this section. The ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions. ServicePac offerings are country-specific. That is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePacs might be available in a particular country. For more information about ServicePac offerings available in your country, see the ServicePac Product Selector at: https://www-304.ibm.com/sales/gss/download/spst/servicepac The following table explains warranty service definitions in more detail. Table 20. Warranty service definitions Term Description Onsite repair A service technician will come to the server's location for equipment repair. 24x7x2 hour A service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is completed. We provide service around the clock, every day, including holidays. 24x7x4 hour A service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is completed. We provide service around the clock, every day, including holidays. 9x5x4 hour A service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding holidays. If after 1:00 p.m. it is determined that onsite service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician will arrive by the end of the following business day. 9x5 next A service technician is scheduled to arrive at your customer’s location on the business day after we business day receive your call, following remote problem determination. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding holidays. In general, the types of ServicePacs are: Warranty and maintenance service upgrades One, 2, 3, 4, or 5 years of 9x5 or 24x7 service coverage Onsite repair from next business day to 4 or 2 hours One or two years of warranty extension Remote technical support services One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities Installation and startup support for System x servers Remote technical support for System x servers Software support - Support Line Microsoft or Linux software VMware IBM Systems Director System x3850 X5 32 Regulatory compliance The server conforms to the following international standards: Multiprocessor Specification (MPS) 1.4 Hardware-enabled to meet ISO 9241, Part 3 FCC - Verified to comply with Part 15 of the FCC Rules, Class A Canada ICES-003, issue 4, Class A IEC/UL 60950-1, 2nd Edition CAN/CSA - C22.2 No. 60950-1-07 2nd Edition NOM-019 (This server is certified by the respective UL and NOM agencies.) External disk storage expansion The following table lists the external SAS disk storage expansion enclosures that are available. Table 21. External expansion enclosures Part number Description Maximum quantity supported per one controller 610012X EXP2512 Express 18 610024X EXP2524 Express 9 The following table lists the drives that are supported by EXP2512 external expansion enclosures. Table 22. Drive options for EXP2512 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 3.5" NL SAS HS HDDs 00NC555 2TB 7,200 rpm 6Gb SAS NL 3.5" HDD 12 00NC557 3TB 7,200 rpm 6Gb SAS NL 3.5" HDD 12 00NC559 4TB 7,200 rpm 6Gb SAS NL 3.5" HDD 12 System x3850 X5 33 The following table lists the hard disk drives that are supported by EXP2524 external expansion enclosures. Table 23. Drive options for EXP2524 external expansion enclosures Part number Description Maximum quantity supported per one enclosure 2.5" NL SAS HS HDDs 00NC571 1TB 7,200 rpm 6Gb SAS NL 2.5" HDD 24 2.5" SAS HS HDDs 00NC561 146GB 15,000 rpm 6Gb SAS 2.5" HDD 24 00NC563 300GB 15,000 rpm 6Gb SAS 2.5" HDD 24 00NC565 600GB 10,000 rpm 6Gb SAS 2.5" HDD 24 00NC567 900GB 10,000 rpm 6Gb SAS 2.5" HDD 24 00NC569 1.2TB 10,000 rpm 6Gb SAS 2.5" HDD 24 2.5" SAS HS SSDs 00NC573 200GB 6Gb SAS 2.5" SSD 24 00NC575 400GB 6Gb SAS 2.5" SSD 24 The RAID controllers listed in the following table are supported with external expansion enclosures. Table 24. RAID controllers for external storage expansion enclosures Part number Feature code Description Maximum supported 46M0830 0094 ServeRAID M5025 SAS/SATA Controller 2 46M0930 5106 ServeRAID M5000 Series Advance Feature Key† 1 per one M5025 81Y4426 A10C ServeRAID M5000 Series Performance Accelerator Key† 1 per one M5025 † Only one key is supported in each controller, either the Advance Feature Key or the Performance Accelerator Key. The ServeRAID M5025 SAS/SATA Controller has the following specifications: Two Mini-SAS external connectors Supports RAID levels 0, 1, 5, 10, and 50 Supports RAID 6 and 60 with the optional M5000 Advanced Feature Key Performance optimization for SSD drives with optional M5000 Series Performance Accelerator Key 6 Gbps throughput per port PCI Express 2.0 x8 host interface Based on the LSI SAS2108 6 Gbps ROC controller 512 MB of onboard cache Intelligent Li-Ion-based battery backup unit with up to 48 hours of data retention Supports connectivity to the EXP3000, EXP2512, and EXP2524 storage expansion enclosures For more information, see the Lenovo Press Product Guide ServeRAID M5025 SAS/SATA Controller for System x , TIPS0739, at: http://www.redbooks.ibm.com/abstracts/tips0739.html?Open System x3850 X5 34 The external SAS cables listed in the following table are supported with external expansion enclosures and M5025 RAID controllers. Table 25. External SAS cables for external storage expansion enclosures Part number Description Maximum quantity supported per enclosure* 39R6531 3 m SAS Cable 1 39R6529 1 m SAS Cable 1 * Note: The EXP3000 and EXP2500 series can be chained with each other. In such a case, one cable is used to connect first EXP25xx or EXP3000 to the RAID controller, and every consecutive EXP unit is connected to the previous one by one cable. External disk storage systems The following table lists the external storage systems that are supported by x3550 M4 and can be ordered through System x sales channel. The server may support other disk systems that are not listed in this table. Refer to IBM System Storage Interoperability Center for further information, http://www.ibm.com/systems/support/storage/ssic Table 26. External disk storage systems Part number Description 2071CU2 IBM Storwize V3500 LFF Dual Control Enclosure 2071CU3 IBM Storwize V3500 SFF Dual Control Enclosure 6099L2C IBM Storwize V3700 3.5-inch Storage Controller Unit 6099S2C IBM Storwize V3700 2.5-inch Storage Controller Unit 6099T2C IBM Storwize V3700 2.5-inch DC Storage Controller Unit 6194L2C IBM Storwize V5000 LFF Control Enclosure 6194LEU IBM Storwize V5000 LFF Expansion Enclosure 6194S2C IBM Storwize V5000 SFF Control Enclosure 6194SEU IBM Storwize V5000 SFF Expansion Enclosure 6195SC5 IBM Storwize V7000 2.5-inch Storage Controller Unit 6195LEF IBM Storwize V7000 3.5-inch Storage Expansion Unit 6195SEF IBM Storwize V7000 2.5-inch Storage Expansion Unit For more information, see the list of Lenovo Press Product Guides in the System Storage category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=externalstorage System x3850 X5 35 External backup units The server supports the external backup attachment options listed in the following table. Table 27. External backup options (Part 1) Part number Description External tape expansion enclosures for internal tape drives 87651UX 1U Tape Drive Enclosure 8767HHX Half High Tape Drive Enclosure 87651NX 1U Tape Drive Enclosure (with Nema 5-15P LineCord) 8767HNX Half High Tape Drive Enclosure (with Nema 5-15P LineCord) Tape enclosure adapters (with cables) 44E8869 USB Enclosure Adapter Kit 40K2599 SAS Enclosure Adapter Kit Internal backup drives supported by external tape enclosures 46C5399 DDS Generation 5 USB Tape Drive 39M5636 DDS Generation 6 USB Tape Drive 49Y9898 Half High LTO Gen 5 Internal SAS Tape Drive 00D8924 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive System x3850 X5 36 Table 27. External tape options (Part 2) Part number Description External backup units* 3628L5X Half High LTO Gen 5 External SAS Tape Drive (with US line cord) 3628N5X Half High LTO Gen 5 External SAS Tape Drive (without line cord) 3580S3V TS2230 Tape Drive Express Model H3V 3580S4V TS2240 Tape Drive Express Model H4V 3580S5E TS2250 Tape Drive Express Model H5S 3580S5X TS2350 Tape Drive Express Model S53 3572S4R TS2900 Tape Library with LTO4 HH SAS drive & rack mount kit 3572S5R TS2900 Tape Library with LTO5 HH SAS drive & rack mount kit 35732UL TS3100 Tape Library Model L2U Driveless 35734UL TS3200 Tape Library Model L4U Driveless 46X2682† LTO Ultrium 5 Fibre Channel Drive 46X2683† LTO Ultrium 5 SAS Drive Sled 46X2684† LTO Ultrium 5 Half High Fibre Drive Sled 46X2685† LTO Ultrium 5 Half High SAS Drive Sled 46X6912† LTO Ultrium 4 Half High Fibre Channel Drive Sled 46X7117† LTO Ultrium 4 Half High SAS DriveV2 Sled 46X7122† LTO Ultrium 3 Half High SAS DriveV2 Sled * Note: The external tape drives listed can be ordered through System x sales channel. Server may support other tape drives that are not listed in this table. Refer to IBM System Storage Interoperability Center for further information. † Note: These part numbers are the tape drives options for 35732UL and 35734UL. For more information, see the list of Lenovo Press Product Guides in the Backup units category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tape System x3850 X5 37 Top-of-rack Ethernet switches The server supports the top-of-rack Ethernet switches from Lenovo listed in the following table. Table 28. Top-of-rack switches Part number Description 1 Gb top-of-rack switches 7309BAX RackSwitch G7028 (24 ports) 7309CAX RackSwitch G7028 (48 ports) 0446013 RackSwitch G8000R 7309CFC RackSwitch G8000F 7309G52 RackSwitch G8052R 730952F RackSwitch G8052F 10 Gb top-of-rack switches 7309DRX RackSwitch G8264CS (Rear to Front) 7309DFX RackSwitch G8264CS (Front to Rear) 7309BR6 RackSwitch G8124ER 7309BF7 RackSwitch G8124EF 7309G64 RackSwitch G8264R 730964F RackSwitch G8264F 7309CR9 RackSwitch G8264TR 7309CF9 RackSwitch G8264TF 40 Gb top-of-rack switches 8036BRX RackSwitch G8332 (Rear to Front) 8036BFX RackSwitch G8332 (Front to Rear) 8036ARX RackSwitch G8316R 8036AFX RackSwitch G8316F For more information, see the list of Lenovo Press Product Guides in the Top-of-rack switches category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=tor System x3850 X5 38 Uninterruptible power supply units The server supports attachments to the uninterruptible power supply (UPS) units listed in Table 24. Table 29. Uninterruptible power supply units Part number Description Rack-mounted or tower UPS units 55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC) 55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC) 55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC) 55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC) 55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC) 55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC) 55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC) 55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC) 55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC) 55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC) 55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) 55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) Rack-mounted UPS units 53951AX 1500VA LCD 2U Rack UPS (100V/120V) 53951KX 1500VA LCD 2U Rack UPS (230V) 53952AX 2200VA LCD 2U Rack UPS (100V/120V) 53952KX 2200VA LCD 2U Rack UPS (230V) 53953AX 3000VA LCD 3U Rack UPS (100 V/120 V) 53953JX 3000VA LCD 3U Rack UPS (200 V/208 V) 53956AX 6000VA LCD 4U Rack UPS (200 V/208 V) 53956KX 6000VA LCD 4U Rack UPS (230 V) 53959KX 11000VA LCD 5U Rack UPS (200V/208V/230V) For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power System x3850 X5 39 Power distribution units The following table lists the server supports attachments to the power distribution units (PDUs). Table 30. Power distribution units (part 1) Part number Description Switched and monitored PDUs 46M4002 1U 9 C19/3 C13 Active Energy Manager DPI® PDU 46M4003 1U 9 C19/3 C13 Active Energy Manager 60A 3-Phase PDU 46M4004 1U 12 C13 Active Energy Manager DPI PDU 46M4005 1U 12 C13 Active Energy Manager 60A 3-Phase PDU Enterprise PDUs 71762MX Ultra Density Enterprise PDU C19 PDU+ (WW) 71762NX Ultra Density Enterprise PDU C19 PDU (WW) 71763MU Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA) 71763NU Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA) 39M2816 DPI C13 Enterprise PDU without linecord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord 39Y8941 DPI Single Phase C13 Enterprise PDU without line cord 39Y8948 DPI Single Phase C19 Enterprise PDU without line cord Front-end PDUs 39Y8934 DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector 39Y8935 DPI 63amp/250 V Front-end PDU with IEC 309 2P+Gnd connector 39Y8938 30 amp/125 V Front-end PDU with NEMA L5-30P connector 39Y8939 30 amp/250 V Front-end PDU with NEMA L6-30P connector 39Y8940 60 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector Universal PDUs 39Y8951 DPI Universal Rack PDU with US LV and HV line cords 39Y8952 DPI Universal Rack PDU with CEE7-VII Europe LC 39Y8953 DPI Universal Rack PDU with Denmark LC 39Y8954 DPI Universal Rack PDU with Israel LC 39Y8955 DPI Universal Rack PDU with Italy LC 39Y8956 DPI Universal Rack PDU with South Africa LC 39Y8957 DPI Universal Rack PDU with UK LC System x3850 X5 40 Table 30. Power distribution units (part 2) Part number Description 39Y8958 DPI Universal Rack PDU with AS/NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Universal Rack PDU (Argentina) 39Y8960 DPI Universal Rack PDU (Brazil) 39Y8961 DPI Universal Rack PDU (India) 0U Basic PDUs 46M4122 0U 24 C13 16A 3-Phase PDU 46M4125 0U 24 C13 30A 3-Phase PDU 46M4128 0U 24 C13 30A PDU 46M4131 0U 24 C13 32A PDU 46M4140 0U 12 C19/12 C13 60A 3-Phase PDU 46M4143 0U 12 C19/12 C13 32A 3-Phase PDU For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=power System x3850 X5 41 Rack cabinets The server supports the rack cabinets listed in the following table. Table 31. Rack cabinets Part number Description 93072PX 25U Static S2 Standard Rack 93604EX 42U 1200 mm Deep Dynamic Expansion Rack 93604PX 42U 1200 mm Deep Dynamic Rack 93614EX 42U 1200 mm Deep Static Expansion Rack 93614PX 42U 1200 mm Deep Static Rack 93624EX 47U 1200 mm Deep Static Expansion Rack 93624PX 47U 1200 mm Deep Static Rack 93072RX 25U S2 standard Rack 14102RX 25U standard Rack 93074RX NetBAY S2 42U Standard Rack Cabinet 93074XX 42U S2 expansion Rack 93084EX 42U Enterprise Expansion Rack 93084PX 42U Enterprise Rack 14104RX 42U S2 standard Rack 99564RX S2 42U Dynamic Standard Rack Cabinet 99564XX S2 42U Dynamic Expansion Rack Cabinet For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack System x3850 X5 42 Rack options The server supports the rack console switches and monitor kits listed in the following table. Table 32. Rack options Part number Feature code Description Monitor kits and keyboard trays 17238BX 1723HC1 fc A3EK 1U 18.5" Standard Console 17238EX 1723HC1 fc A3EL 1U 18.5" Enhanced Media Console 172317X 1723HC1 fc 0051 1U 17in Flat Panel Console Kit 172319X 1723HC1 fc 0052 1U 19in Flat Panel Console Kit 1754D2X 1754HC2 fc 6695 Global 4x2x32 Console Manager (GCM32) 1754D1X 1754HC1 fc 6694 Global 2x2x16 Console Manager (GCM16) 1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager (LCM16) 1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager (LCM8) 43V6147 3757 Single Cable USB Conversion Option (UCO) 39M2895 3756 USB Conversion Option (4 Pack UCO) 39M2897 3754 Long KVM Conversion Option (4 Pack Long KCO) 46M5383 5341 Virtual Media Conversion Option Gen2 (VCO2) 46M5382 5340 Serial Conversion Option (SCO) Console switches Console cables For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category: http://www.redbooks.ibm.com/portals/systemx?Open&page=pg&cat=rack System x3850 X5 43 Related publications and links For more information see the following resources: System x3850 X5 product page http://www.ibm.com/systems/x/hardware/enterprise/x3850x5/ System x 3850 X5 Installation and User's Guide http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5085479 System x 3850 X5 Problem Determination and Service Guide http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5084848 ServerProven hardware compatibility page for the x3850 X5 http://ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/7145.html Lenovo Press Product Guides for System x servers and options http://www.redbooks.ibm.com/portals/systemx?Open&page=pgbycat Configuration and Option Guide http://www.ibm.com/systems/xbc/cog/ xREF: System x Reference http://www.redbooks.ibm.com/xref System x Support Portal http://ibm.com/support/entry/portal/ http://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3850_X5 System x3850 X5 44 Notices Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: Lenovo (United States), Inc. 1009 Think Place - Building One Morrisville, NC 27560 U.S.A. Attention: Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. © Copyright Lenovo 2011-2015. All rights reserved. System x3850 X5 45 This document was created or updated on January 20, 2015. Send us your comments in one of the following ways: Use the online Contact us review form found at: ibm.com/redbooks Send your comments in an e-mail to: redbooks@us.ibm.com This document is available online at http://www.ibm.com/redbooks/abstracts/tips0817.html . Trademarks Lenovo, For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by Lenovo at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of Lenovo trademarks is available on the Web at http://www.lenovo.com/legal/copytrade.html. The following terms are trademarks of Lenovo in the United States, other countries, or both: Dynamic System Analysis™ eX5™ eXFlash™ Lenovo® MAX5™ RackSwitch™ Lenovo(logo)® ServeRAID™ ServerGuide™ ServerProven® System x® X5™ The following terms are trademarks of other companies: Intel, Intel Xeon, Intel logo, Intel Inside logo, and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. System x3850 X5 46
© Copyright 2024