Open a new chapter in vision with IMAGE 1 SPIESTM – ICG Chapter I In Vivo Fluorescence Imaging Applications VISUALIZATION – BILIARY TRACT White light ICG standard mode ICG-SPECTRA A mode Fluorescence cholangiography during a cholecystectomy Ductus Cysticus Prof. Martin Walz, Klinikum Essen-Mitte, Germany PERFUSION – BOWEL White light ICG standard mode ICG-SPECTRA A mode ICG perfusion control of an intestinal segment before sigma resection well-perfused and poorly perfused area Prof. Dr. Luigi Boni, University of Umbria, Varese, Italy DETECTION – LYMPH NODES White light ICG standard mode ICG-SPECTRA A mode Detection of lymph nodes during a prostatectomy, Prof. Günter Janetschek, University Hospital of Salzburg, Salzburg, Germany Visualisation of the lymph node pathway in real time by laparoscopic radioisotope- and fluorescence-guided sentinel lymph node dissection in prostate cancer staging. Jeschke S. et al., Nov;80(5): 1080-6.Urology 2012. IMAGE 1 SPIES™ • Sustainability due to the possibility of integrating up to three camera units • Versatile camera platform Endoscopes for NIR visualization • Maximal fluorescence excitation and detection • Can be used for white light and ICG applications It is recommended to check the suitability of the product for the intended procedure prior to use. D-LIGHT P COLD LIGHT FOUNTAIN • Fast switchover between white light and fluorescence mode via footswitch • Compatible with the KARL STORZ product portfolio IMAGE 1 SPIES™ H3-Z FI camera head • Optimized for fluorescence imaging in the NIR spectral range • 3-chip FULL HD camera head Autoclavable fiberglass light cable • Optimal light transmission in the white light and NIR spectral range Open a new chapter in fluorescence imaging Perfusion control with indocyanine green (ICG) provides visual support in minimally invasive procedures. The substance ICG is non-radioactive and cost-effective. The NIR system from KARL STORZ enables you to detect ICG in near infrared up to 1 cm beneath the tissue surface in different applications. What are the main features of the KARL STORZ NIR system? Image quality Ease of use Brilliant FULL HD image quality. Quick and easy switchover via footswitch between fluorescence and standard white light views. Compatibility Enhanced fluorescence imaging All system components can be used for standard white light procedures. Additional enhancement of the fluorescence signal with more background illumination in SPECTRA A mode. Interdisciplinary use Expandability Successful use in various disciplines. Possibility of system extension for up to three camera units. KARL STORZ GmbH & Co. KG Mittelstraße 8, 78532 Tuttlingen, Germany Postbox 230, 78503 Tuttlingen, Germany Phone: +49 (0)7461 708-0 Fax: +49 (0)7461 708-105 E-Mail:info@karlstorz.com www.karlstorz.com KARL STORZ Endoscopy-America, Inc. 2151 East Grand Avenue El Segundo, CA 90245-5017, USA Phone: +1 424 218-8100 Phone toll free: 800 421-0837 (US only) Fax: +1 424 218-8525 Fax toll free: 800 321-1304 (US only) E-Mail: info@ksea.com 96261002 FI 2 1.0 10/2014/MFL-E ...evolution continues
© Copyright 2024